Transcript
BIONET AMERICA, INC. BIONET AMERICA, INC.
MEDICAL PRODUCT S A L E S N O T E S M E D I2C•A0L • P1R •O 0D U C T S A L E S N O T E S Revised: September 2010 2 • 0 • 1 • 0 Revised: September 2010
ECG
Patient Monitor
Fetal Monitor
ECG
Patient Monitor
Fetal Monitor
www.BionetUS.com
T.714.734.1760
F.714.734.1761
[email protected]
www.BionetUS.com
T.714.734.1760
F.714.734.1761
[email protected]
Bionet Corporation
About Bionet Corporation (Headquartered in Seoul, Korea)
Bionet is a leading manufacturer of biosignal medical equipment such as ECGs, fetal and patient monitoring systems. With innovative, yet affordable, new technology, Bionet brings you products designed to make diagnosis easier, quicker, and more economical.
Bionet Global Network
Over 100 sales agents and dealers spread across some 80 countries MGB (Germany)
y
|¡ n
(China)
r ¡GyU h¡
(CA, North America)
r
z p
(FL. Latin America)
t
h
p
p |hl
u {
w
zGh
i p {
n }¡
(Korea) r
q
l
t j
h
z s
{
{
t
h
zGsG
u
lG
o
s } j t w p
wG
(Thailand) h
j |
h
2
yUGGzGh
uGG
Bionet America(Medical)
About Bionet America
As an extension of Bionet Corporation, Bionet America, Inc. (Tustin, California) was established in September 2002 to serve the North American region 1. Medical Products: ECGs, Patient Monitors & Fetal Monitors CardioTouch 3000 Interpretive 12 Channel Resting ECG w/ Large Color LCD Touch Screen
CardioCare 2000 Cost-Effective Interpretive 12 Channel Resting ECG
BM3 Plus Multi-parameter Vital Signs Monitor w/ ECG, SpO2, NIBP, Respiration and Temp. FC 700 Cost-Effective Single Fetus Monitor
Twin View - FC 1400 Twin Fetus Monitor w/ Color LCD
Bionet America(Veterinary)
About Bionet America (Cont’d) 2. Veterinary Products:
̶ Multi-Parameter Vet Monitors BM1Vet
BM3Vet Next
SpO2, NIBP, Temp, EtCO2
ECG, SpO2, NIBP, Respiration, Temp, EtCO2
BM5Vet ECG, SpO2, NIBP, Respiration, Dual Temp, Dual IBP, EtCO2
Oxy9Vet Plus Hand Held Pulse Oximeter
3
Bionet ECGs
Sales Notes ECGs
Bionet ECGs
What does an ECG do? ECG (Electrocardiogram) is a graphic recording of electrical activity generated by the heart. ECG is acquired by measuring the subtle voltage differences on the body surface around the heart. ECG is used to diagnose heart diseases such as myocardial infarction, arrhythmia, etc.
ECG example : Bio-electric potential between right arm and left foot
4
Bionet ECGs
CardioCare 2000 Bionet’s Best Selling Interpretive 12Channel Resting ECG • Full size print-outs with 12channel interpretive ECG • Over 130 kinds of interpretation results based on advanced Minnesota code • Connection with PC software, EKG-Plus II, through LAN
Bionet ECGs
Why CardioCare 2000? 1. 3 Year Warranty! 2. Superior Design & Portability! 3. Features! 4. Customer Service! 5. Complete & Ready To Use Out of the Box! 5
So ha ft-r n d ub le be fo r c rp a or rry ta ing bi lit y
Bionet ECGs
2. Superior Design & Portability LAN port for PC connection
Character Display for Heart Rate, Device Setting Status One-touch operation Alpha-numeric keys for Entering Patient Information
Built-in full size thermal printer for 12ch ECG print-out & easy chart filing Plain thermal fax paper can be used
Rechargeable battery for portability
Bionet ECGs
3. Features High Quality •
12ch ECG (simultaneous 12 channel acquisition)
•
Interpretation based on advanced Minnesota code
Convenience •
Easy to use with one-touch operation
•
Full size paper – Easy and convenient filing
•
Various printing formats
Cost-effectiveness
6
•
Free firmware upgrades
•
Free ECG PC software: EKG-Plus II
Bionet ECGs
3. Features 3.1. Simultaneous 12channel acquisition Lead I
…….
Lead II Lead III AVR AVF V1 V2 V3 V4 V5
V6
…………...
AVL
3 or 6ch device acquires only 3 or 6ch data at a time.
12ch device acquires all the cardiac data simultaneously
ÆIt’s a very important clinical point.
Bionet ECGs
3. Features 3.2. Built-in ECG interpretation program
ECG ECG Interpretation Interpretation results results are are given given through through the the automatic automatic interpretation interpretation program program which which is is based based on on the the advanced Minnesota code and has advanced Minnesota code and has completed completed over over 5,000 5,000 cases cases of of clinical clinical trial. trial. Interpretation Interpretation program program can can be be upgraded upgraded through through firmware firmware updates updates made made available available from from the the Bionet Bionet website. website.
7
Bionet ECGs
3. Features 3.3. Full Size Print-out for easy chart filing Date / Time 2006-06-22 14:20 ID : Name : Sex : Hei. : Room :
Age : Wei. : Dept. :
Patient Information
HR PR int.
QRS dur. QT/QTc
Report Form 6 Channel + 1 Rhythm Report
60bpm 166ms
Normal Sinus Rhythm Normal Axis
82ms
358/355ms
[ Normal ECG]
P-R-T axes 60 41 42
Hospital : Bionet Referred by
Interpretation Result
Hospital & Doctor Information
Parameters
ECG Graphic Data Display 1ch(60sec.), 3, 6 and 12ch forms
0.1-150Hz, AC60Hz
10mm/mV, 25mm/s
EKG2000 Ver5.04US.30
Bionet Co., Ltd
Device Setting, Software Version and Company Information
Bionet ECGs
3. Features 3.4. Can use thermal fax paper
“Can use thermal fax paper which is readily available from office supply stores in a pinch” 8
Bionet ECGs
3. Features 3.5. keys
1. Gain size of ECG (mm/mV): 5,10,20,aut(I-aVF:10, V1-V6:5)
2. Printing speed (mm/sec): 12.5, 25, 50
3. Base line Filter: ON/OFF 4. Muscle Filter: ON/OFF 5. Network function 6. Printout forms:
3ch+1rhy, 6ch+1rhy, 12ch, 60s+1rhy
7. Rhythm channel 8. Patient information 9. Monitoring Print 0. Recording Print Copy Print
*Red is default setting.
XX
Bionet ECGs
3. Features 3.6. Computer interface : EKG-Plus II (Refer to EKG-Plus II Section for Detail)
EKG-Plus II is a software program that enables you to interface CardioCare 2000 to Windows based computers through LAN. The ECG data from CardioCare 2000 is saved in either Bionet’s proprietary file format(.ecg) or jpeg image file on PC. The JPEG file format ensures compatibility with most EMR packages.
ECG JPEG image
ECG Data
CardioCare 2000
EKG-Plus II
Hospital Information System
9
Bionet ECGs
4. Customer Service ̶ High level of customer satisfaction:
People like our products & service staff
̶ Complimentary telephone based training & ongoing technical support
̶ No nonsense support and service ̶ US based technical support – no language/accent issues
Bionet ECGs
5. Complete & Ready To Use Out of Box ̶ 10 lead ECG patient cable with alligator clips ̶ 1 pack of electrodes(100 electrodes) ̶ 1 roll of archival thermal paper ̶ Hospital Grade Power Cord The only thing we don’t supply is the patient!
10
Bionet ECGs
CardioTouch 3000 Bionet’s Advanced Interpretive 12Channel Resting ECG with Color LCD Touch Screen • Full size print-outs with 12channel interpretive ECG • Color TFT LCD with 12channel simultaneous display and Touch screen for intuitive operation • Memory for up to 120 patients
Bionet ECGs
Why CardioTouch 3000? 1. 3 Year Warranty! 2. Superior Design & Portability! 3. Advanced Features! 4. Customer Service! 5. Complete & Ready To Use Out of the Box! 11
So ha ft-r n d ub le be fo r c rp a or rry ta ing bi lit y
Bionet ECGs
2. Superior Design & Portability LAN port for PC connection
4.3” Wide Color LCD with touch screen and 12ch ECG preview Rotary key access to all menus
Built-in full size thermal printer for 12ch ECG print-out & easy chart filing Thermal fax paper can be used
Rechargeable battery for portability
Bionet ECGs
3. Advanced Features 3.1. User friendly interface
reen c s h To u c
12
Real-time ECG preview for checking signal quality Convenient touch screen operation Rotary key for easy menu navigation Pediatric Interpretation Memory for up to 120 patients
Bionet ECGs
3. Advanced Features 3.2. Preview, Adjust, and Record
Monitoring Current ECG
Change Sensitivity, Speed, Filter and so on
Recording
Bionet ECGs
3. Advanced Features 3.3. Patient Info., Save, and Review
Enter Patient Information with touch interface
Save current ECG together with patient information
Saved patient data list
13
Bionet ECGs
3. Advanced Features 3.4. Beat report for detailed interpretation
Detailed Detailed measurement measurement data data for for professional professional interpretation. interpretation.
Bionet ECGs
3. Features 3.5. Computer interface : EKG-Plus II (Refer to EKG-Plus II Section for Detail)
EKG-Plus II is a software program that enables you to interface CardioTouch 3000 to Windows based computers through LAN. The ECG data from CardioTouch 3000 is saved in either Bionet’s proprietary file format(.ecg) or jpeg image file on PC. The JPEG file format ensures compatibility with most EMR packages.
ECG JPEG image
ECG Data
CardioTouch 3000
14
EKG-Plus II
Hospital Information System
Bionet ECGs
4. Customer Service ̶ High level of customer satisfaction:
People like our products & service staff
̶ Complimentary telephone based training & ongoing technical support
̶ No nonsense support and service ̶ US based technical support – no language/accent issues
Bionet ECGs
5. Complete & Ready To Use Out of Box ̶ 10 lead ECG patient cable with alligator clips ̶ 1 pack of electrodes(100 electrodes) ̶ 1 roll of archival thermal paper ̶ Hospital Grade Power Cord The only thing we don’t supply is the patient!
15
Bionet ECGs
What’s EKG-Plus II? EKG-Plus II is a software program that enables you to interface all Bionet ECG devices, including CardioCare 2000 and CardioTouch 3000, to Windows based computers through LAN. The ECG data from Bionet ECG devices is saved in either Bionet’s proprietary file format(.ecg) or jpeg image file on PC. This JPEG file format ensures compatibility with most EMR packages.
ECG D a
ta
CardioCare 2000
ECG JPEG image
ta ECG Da
CardioTouch 3000
Bionet ECGs 16
EKG-Plus II
Hospital Information System
Why EKG-Plus II? ECG records have to be kept as part of the patient record. Recently, since electronic medical records have become prevalent, the ability to store ECG data in the electronic medical record is a must have. As a simple and powerful solution, Bionet provides EKG-Plus II software to connect the CardioCare 2000 and CardioTouch 3000, get the ECG data from them, and convert it to a JPEG image to be sent to the current electronic medical record. In addition, you can print ECGs directly to your Windows based printer as well as providing some useful tools like a magnifying glass, direct measurement, print preview and so on.
Bionet ECGs
Connection Methods
Bionet ECGs
Features preview and control Bionet ECG machines • Transfer ECGs from the machine to your computer • Control everything from the computer • Includes both a monitor and record mode
Save and recall ECGs on your computer • Change ECG settings (sensitivity, filters, output) • Add custom comments to the ECG • Magnify sections of the ECG tracing for easy reading • Measure ECG complexes with easy to use tools • Compare two different ECGs side by side • Save ECGs in JPG format which ensures compatibility with most EMR packages
Print your ECGs from your Windows based printer • View a real time preview before you print
17
Bionet ECGs
One-click menu bar Tool bar to open, close, save, change display mode, start monitoring, start recording, print, and see help
Patient Information
Color bar to change the grid or graph color
ECG bar to change the ECG graph viewer control
ECG display
In
r te
a ch
l ab e ng
Display mode : 3Ch, 6Ch, 12Ch,
e
Two ECGs display, Beat Report
ECG analysis result
Bionet ECGs
Work Flow
Monitoring ECG from Connected Device
Save as ***.jpg
18
Recording
Save as ***.ecg
Reviewing
Preview & Printing
Bionet ECGs
Reviewing Tools
Beat Report
Dual ECG display for Comparison
(Not available on CardioCare 2000)
Measurement of width and height
Magnifying Glass
Bionet ECGs
Customer’s Benefit • EKG-Plus II Software is available as a free download for all Bionet ECG users. • visit http://www.bionetus.com to download software and operation manual • Bionet America offers paid telephone based support for the EKG-Plus II software.
19
Bionet ECGs
What’s the Bionet EKG SDK? Bionet EKG SDK is a software development kit to assist programmers in developing applications and interfaces to Practice Management Software, EMR software, Hospital Information Software, and so on. Bionet EKG SDK provides an ActiveX component which can be used in the Windows environment. This ActiveX component enables the current hospital information system to receive ECGs from Bionet ECG devices, save them and review them with an ECG viewer which is provided from the ActiveX component.
Bionet ECGs
What’s Provided? Component file(EKGCom.ocx) • Supported operating system : Windows O/S • Supported development language : All development languages able to use ActiveX components.
User’s Guide Sample Program Sources • Sample source for Visual Basic : EKGDemoVB.zip • Sample source for Visual C++ : EKGDemoVC.zip
visit http://www.bionetus.com to download Bionet EKG SDK
User Guide
20
CardioCare 2000 Quick Guide
CardioTouch 3000 Quick Guide
21
Data Saving
User interface
Resolution
Screen
Thermal (210mm)
Last one
Key, Knob
2x16 characters
Character LCD
500hz
3/6/12CH ECG Interpretation
Bionet
CardioCare 2000
LAN, Serial, XML export, GSM wireless
Thermal (110mm)
50ECGs
AlphaNumeric
192x64 pixels
3.5", Mono
1000hz
6CH ECG Interpretation, 2-step exercise test, HRV analysis
EDAN
SE-601A
no
RS-232
Thermal (50mm)
50ECGs
Numeric Entry Hard key
2x20 characters
Character LCD
?
3CH ECG Non-interpretive
Burdick
EK-10
11lb (5kg)
HeartCentrix
LAN, W-LAN, Bluetooth, EMR connectivity
Thermal (210mm)
50ECGs
AlphaNumeric
2x40 characters
Character LCD
8,000hz ADC 500hz Storage
12CH ECG University of Glasgow Interpretation Algorithm, Pediatric analysis
Burdick
Atria 3100
2 year
1kg
CARDIOLINE
IR
Thermal (60mm)
Last one
Key
32x120 pixels
Backlit Graphic LCD
1,000hz
3CH ECG Optional Interpretation
Cardioline
ar600
2hours, 300ECGs
2 year
1.85kg
CARIOLINE
IR
Thermal (110mm)
Last one
Key
32x120 pixels
Backlit Graphic LCD
1,000hz
3/6CH ECG Interpretation Arrythmia(option), HRV(option)
Cardioline
ar1200ADV
1hour, 220ECGs
2 year
4.8kg
CARDIOLINE
IR
Thermal (210mm)
40ECGs
AlphaNumeric
32x120 pixels
Backlit Graphic LCD
1,000hz
3/6/12CH ECG Interpretation Arrythmia(option), HRV(option)
Cardioline
ar2100
400ECGs
3 year
4.8kg
no
no
Thermal (210mm)
Last one
Key
no
no
1,000hz
Schiller
AT2
Lead acid, Li-ion
2 year
6.95kg
no
Serial
Thermal (210mm)
Last one
key, knob, key board
2x40 characters
Charaecter LCD
2,000hz
Philips
Trim I
Recharge Battery
1 year
11.34kg
E-Scribe/NT
RS232, internal modem
Thermal (210mm)
40-150ECGs
AlphaNumeric
2 character lines
Charaecter LCD
10,000hz ADC 500hz Analysis
Motara
ELI 200
CardioCare 2000 - Market Comparison
Printer
LAN, Serial, FAX transmission
Smart ECG Viewer
9lb (4.1kg)
3 year
3hours, 300ECGs
Features \ Model
Networking
EKG Plus II
appro. 3kg
3 year
NiMH
Sampling Rate
Measurements
Vendor
Design
PC Software 2.98kg
2 year
NiCad
12CHECG Interpretation
Weight
3 year
Li-ion(280ECGs)
12CH ECG Optional Interpretation 6/12CH ECG Optional Interpretation (558 interpretations, 8 severity levels)
Warranty
Ni-MH(100ECGs)
Rechargeable Battery
22
Features \ Model
Rechargeable Battery
Ni-MH(100ECGs)
3 year
Warranty
PC Software
2.98kg
EKGPlus II
Networking
Weight
Ethernet, RS232, USB
LAN, Serial, XML export, GSM wireless
LAN, Serial
Li-ion(280 ECGs)
2 year
appro. 3kg
Smart ECG Viewer
Thermal (210mm)
Thermal (110mm)
Thermal (210mm)
Printer
Li-ion(100 ECGs)
2 year
?
Smart ECG Viewer
100ECGs
200ECGs
120ECGs
AlphaNumeric
320x240
Data Saving
AlphaNumeric
640x480
5.7", Mono
Touch, Key, Rotary
480x272
5.7", Color
1,000hz
User interface
Resolution
4.3", Color Touch
Screen
1,000hz
12CH ECG, interpretation, 2-step exercise test
6CH ECG Interpretation, 2-step exercise test, HRV
12CH ECG, Interpretation
500 sample/sec
EDAN
SE1200
EDAN
SE601C
3 year Lead Acid (100 ECGs)
Lead Acid (100 ECGs)
5.3kg
CardioPerfect
SD card, COM port for USB
3 year
5.3kg
CardioPerfect
SD card, COM port for USB
Thermal (210mm)
50ECGs
No internal Storage, Unlimited(SD card) Thermal (210mm)
AlphaNumeric
Text, ECG graph
Color
>1000hz
3/6/12CH ECG interpretation
Welch Allyn
CP200 interpretive
AlphaNumeric
Text Only
Mono
>1000hz
3/6/12CH ECG interpretation
Welch Allyn
CP100 interpretive
Ni-Cad
3 year
400 ECGs
3 year
4.8kg
SEMA-200
MUSE, CardioSys 5.6kg
RS232
Thermal (210mm)
60ECGs(option)
AlphaNumeric
Text, ECG graph
Mono
1000hz
6/12CH ECG Interpretation
Schiller
CARDIOVIT AT-2
RS232
Thermal (210mm)
40ECGs
AlphaNumeric
320x240
Mono
1000hz
12CH ECG interpretation
GE
Mac 1200
CardioTouch 3000 - Market Comparison
Bionet
CardioTouch 3000
Sampling
Measurements
Vendor
Design
23
NiMH(300 ECGs)
3 year
5kg
HeartCentrix
LAN, W-LAN, Bluetooth, EMR connectivity
Thermal (210mm)
150-300 ECGs
AlphaNumeric
640x480
Color
8,000hz ADC, 500hz Storage
12CH ECG University of Glasgow Interpretation Algorithm, Pediatric analysis
Burdick
Atria 6100
1hour
4 year
2kg
optional ECG Viewer
USB, LAN, SD card
Thermal (110mm)
40ECGs 3000ECGs(SD card)
AlphaNumeric
320x240
5.7", Color
8,000hz ADC, 500hz analysis
3/4/6CH ECG
NihonKohden
cardiofaxS
Lead Acid, Li-ion (40 ECGs)
2 year
7.38kg
TraceMasterVue
LAN, W-LAN(option) Barcode reader(option)
Thermal (210mm)
50ECGs
key, knob, key board
640x480
6.5", 256 Gray
2,000hz
12CH ECG Optional Interpretation (558 interpretations, 8 severity levels)
Philips
Trim II
12 ch ECG Interpretive 12 Channel Resting ECG
CardioCare
2000
* Convenient A4 size print-outs allow for easy chart filing * Copy function allows varied printouts from single patient sample * Grid function allows you to use low cost plain fax paper * One-touch operation (monitoring, recording mode) * Accurate simultaneous 12 channel cardiac data acquisition
Over 130 kinds of interpretation results based on advanced Minnesota code High-Quality 12ch interpretive ECG at a 3ch price Free S/W upgrade via internet
24
SPECIFICATIONS ECG leads Dimension Recording channel Sensitivity Printing speed Sampling rate Filters
Main office : Bionet Co.,Ltd. Tel : +82-2-6300-6418(Int’I) e-mail :
[email protected](Int’I)
www.ebionet.com +82-2-6300-6477(Domestic)
[email protected](Domestic)
North America : Bionet America, Inc. Tel : +1-714-734-1760
www.bionetus.com e-mail :
[email protected]
Europe : MGB Endoskopische Ger-te GmbH Berlin Tel : +49-30-6392-7010
www.mgb-berlin.de e-mail :
[email protected]
China : Bionet China Tel : +86-10-58220564
e-mail :
[email protected]
25
CardioCare2000 0608 Ver1.0 ShinWha
12 lead, simultaneous ECG and acquisition 296(W) 305.5(H) 92.5(D) , Approx.2.98 3,6,12 channel and 1 channel(60 sec) 5, 10, 20, auto(I~aVF: 10, V1~V6: 5) / 12.5, 25, 50 /s 500 samples/sec AC(50/60 , -20 or better) Muscle(25 ~ 35 -3 or better) Base line drift (0.1 -3 or better) Low pass filter (off, 40 , 100 , 150 Display 2 16 character LCD Display LCD display Sensitivity, speed, filter status, HR, printing form, rhythm lead LED indicator signal quality, power source, battery. Keyboard Membrane keyboard, Alphanumeric and symbol available Patient data ID, name, age, sex, height, weight Basic measurement Heart rate, PR int, QRS dur, QT/QTc, P-R-T axis Recorder Thermal print head, Thermal roll paper Report papers : width : A4 : 210 or 8.5 length : A4 : 300 or 11 Effective writing width : 204 Resolution : Vertical : 8 dots/ Horizontal : 16dots/ Electrical Internal noise : 20 (p-p)max Input circuit : Floating input Isolated and defibrillation protected Input impedance : 10M Input voltage range : 5 Common Mode Rejection : 100 DC offset voltage : 300 Time constant : 3.2sec Patient leakage current : <10 Frequency response 0.05~150 Signal quality control Disconnected lead detection Power Power supply : AC or built-in Battery(option) Power requirement : 100 - 240 Vac, 50/60 , 1.0 - 0.5 A Power consumption : 60W max Battery capacity 1 hour of normal use(approximately 100 automatic ECG printouts) Communication PC connection with RS-232 interface and LAN Safety Class I, Type BF Conformity CE, CSA, FDA, KFDA, SFDA, CCC Environment Operating humidity : 30 ~ 85 % Operating Temperature : 10 ~ 40 Atmospheric pressure : 70 ~ 106 KPa Standard accessory Power cord 1 EA, Patient cable 1 EA,Limb 1 set(4 EA), Chest ball 1 set(6 EA), Chart paper 1 EA, Operation manual 1 EA Options Rechargeable battery, Cart, Hanger, Bag, PC S/W * Specifications can be changed without prior notification.
26
27
G
Bionet ECG Item List Cost-Effective Interpretive 12 Channel Resting ECG
CardioCare 2000 (Item Code: ECG-2000)
G
Multi Channel interpretive resting ECG. Prints on full size paper. Built in rechargeable battery. Includes: CardioCare 2000 Main Unit, 10 Lead ECG Patient Cable, Alligator Clips, Electrodes, Medi-Graph Paper, Hospital Grade Power Cord, Operation Manual, Diagnostics Guide Book, Quick Reference Guide and 3 Year Warranty Card.
CardioTouch 3000 (Item Code: ECG-3000)
Interpretive 12 Channel Resting ECG with Color LCD Touch Screen
G
Multi Channel interpretive resting ECG with color LCD Touchscreen. Prints on full size paper. Built in rechargeable battery. Memory Capability up to 120 Patients. Pediatric Diagnosis. Audible QRS. Includes: CardioTouch 3000 Main Unit, 10 Lead ECG Patient Cable, Alligator Clips, Electrodes, Medi-Graph Paper, Hospital Grade Power Cord, Operation Manual, Diagnostics Guide Book, Quick Reference Guide and 3 Year Warranty Card.
Accessories and Supplies (90 Days Warranty) Item Code(Part No.)
ECG-CBL ECG-BAT ECG-CLIP PC-A
10 Lead ECG Patient Cable ECG Rechargeable Battery ECG Alligator Clip(10 pcs/set) Hospital Grade Power Cable
Item(Part) Description
Disposable Accessories and Supplies (No Warranty) Item Code(Part No.)
ECG-RE ECG-PP
Item(Part) Description
ECG Resting Electrode(5 packs/bag) ECG Medi-Graph Paper (10 rolls/box)
Other Accessories Item Code(Part No.)
ECG-CART 28
G
Item(Part) Description
ECG Cart for CC2K & CT3K (90 Days Warranty)
Bionet Patient Monitor
Sales Notes Patient Monitor
Bionet Patient Monitor
What does a Patient Monitor do? It is a medical device capable of continually checking, observing, and recording the vital signs of patients such as ECG, SpO2, Respiration, Blood Pressure, Temperature and other kinds of signs to assist physicians in monitoring anesthetized or critical care patients.
29
Bionet Patient Monitor
What parameters are detected? Electrocardiograph (ECG) : ECG is acquired by measuring the subtle voltage differences on the body surface around the heart to monitor the status of heart function. Heart rate is calculated from ECG in real-time. • HR : Heart rate Non-Invasive Blood Pressure (NIBP) : The force that the circulating blood exerts on the walls of the arteries. • Systolic B.P : Pressure during contraction of the heart • Diastolic BP : Pressure during relaxation phase • Mean BP : Systolic BP + 2 x Diastolic BP / 3 Pulse Oximetry(SpO2) : It provides early information on problems in the delivery of oxygen to the tissue. Those problems may arise because of improper gas mixtures, blocked hoses or airways, inadequate ventilation, diffusion, or circulation, etc. • SaO2 : Arterial Oxygen Saturation • SpO2 : Pulse Oximeter Saturation.
Bionet Patient Monitor
BM3 Plus
Cost-effective portable multi-parameter patient monitor • 8.4” Color TFT LCD Display • ECG, SpO2, NIBP, Respiration and optional Temperature • Saves alarm information for review • Built-in Printer
30
Bionet Patient Monitor
Why BM3 Plus? 1. 3 Year Warranty! 2. Superior Design & Portability! 3. Features! 4. Customer Service! 5. Complete & Ready To Use Out of the Box!
Bionet Patient Monitor
2. Superior Design & Portability k oo
il H m a r e d i d ds Be e rb fo
in nt u o
g
Alarm Lamp on Handle
Built-in 5.8” thermal printer for filing in patient record
8.4” Color LCD Display Distinctive Big number display 2 ECG traces, SpO2, NIBP, Temp. One-touch Operation Alarm Sound On/Off Printer Start/Stop Blood Press Measure Change Display Mode Rechargeable Battery Li-ion battery 2hours of continuous operation 31
Bionet Patient Monitor
3. Features
Superior Advantages •
ECG, SpO2, NIBP, Respiration and Optional Temperature
•
8.4” High resolution screen monitor
•
Individual sweep speed setting for each parameter
•
Multiple display modes including Large Parameter View
•
SpO2 Pitch tone
•
Li-ion rechargeable battery allows cordless use up to 2 hours
Enhanced Data management •
128 full hours of trend data are stored
•
Saves 20 cases of 10 sec alarm waveforms for later review
High-performance Measurement •
Very low-perfusion SpO2 measurement
•
Blood pressure accuracy based on clinical trials
Bionet Patient Monitor
3. Features 3.1. Main Display Parameter Window with Alarm Limit •Heart Rate
2-Trace ECG
•Pulse Rate •Systolic BP •Diastolic BP •Mean BP •%SpO2 •Respiration Rate •Temperature
Intuitive Icons ( Battery, Alarm, Print, System Setting,
32
Patient Info., Trend Pop-up Window, Trend)
Trend Pop-up Window
Bionet Patient Monitor
3. Features 3.2. Multiple display modes
Main Display Mode
Trend Display Mode
• Large Parameter View provides high legibility.
Large Parameter Display Mode
• Trend pop-up window next to real-time waveform provides the comparison between current situation and past situation.
Bionet Patient Monitor
3. Features 3.3. Alarm Saving and Review
33
Bionet Patient Monitor
3. Features 3.4. Graphic Trend View
Time Period 0.5 : 30min. 1 : 1hour 1.5 : 1.5hour 3 : 3hours 6 : 6hours
Bionet Patient Monitor
3. Features 3.5. Tabular Trend View(can also be printed)
Time Period 1 : 1min. 5 : 5min. 15 : 15min. 30 : 30min. 60 : 60min.
34
Bionet Patient Monitor
3. Features 3.6. Printout forms 1. Thermal printer - 58mm - up to 3waveforms - Detailed patient information 2. Printer speed - 25, 50 mm/sec
Bionet Patient Monitor
3. Features 3.7. Robust Internal Structure
Robust internal chassis helps protect the unit against damage from dropping! 35
Bionet Fetal Monitors
4. Customer Service ̶ High level of customer satisfaction:
People like our products & service staff
̶ Complimentary telephone based training & ongoing technical support
̶ No nonsense support and service ̶ US based technical support – no language/accent issues
Bionet Fetal Monitors
5. Complete & Ready To Use Out of Box ̶ 3-lead ECG cable w/ snap type electrodes ̶ Reusable SpO2 finger probe ̶ Reusable NIBP adult cuff ̶ 2 rolls of archival thermal paper ̶ Built-in thermal printer and battery ̶ Hospital Grade Power Cord The only thing we don’t supply is the patient!
36
Features \ Model
3.1kg
3 year
Li-ion
Weight
Warranty
Rechargeable Battery
Central Monitoring System
Li-ion(3hr)
3 year
< 5kg
HyperVisor IV
Serial
LAN Flash Memory Card(Optional: WLAN, memory)
LAN, Nurse Call, VGA Out
Networking
No
Thermal (50mm)
Thermal (50mm)
Thermal (50mm)
Printer
72hr trend, 40sec waveform
128hr trend, 20cases alarm waveform
Data Saving
Lead-acid
2 year
4.3-5.5kg
No
?
?
800x600
800x600
Resolution
LCD + LED
ECG, RR, HR, SpO2, PR, NIBP, Temp.
8.4", Color
ECG, RR, HR, SpO2, PR, NIBP, Temp.
ECG, RR, HR, SpO2, PR, NIBP, 2xTemp. Opt.: 2xIBP, EtCO2 Mortara Arrhythmia, ST analysis
8.4", Color
Welch Allyn
Atlas 622
Mindray
PM8000 Express
Bionet
BM3 Plus
Lead-acid(3hr)
2 year
6.4kg(14lb)
Compatible with EMR
COM, Nurse Call, VGA Out
Thermal
24hr trend
600x480
10.4", Color
ECG, RR, HR, SpO2, PR, NIBP, Temp.
Criticare
8100E nGenuity
Lead-acid(2hr)
?
3 - 6 kg
Yes
Networking
Thermal (Option, 50mm)
200 Cases
320x240
5.7", Color
ECG, SpO2, NIBP
Goldway/Philips
4000A
4000F
Lead-acid(2hr)
?
6.5-9 kg
Yes
LAN, VGA Out
Thermal (Option, 50mm)
6min. Waveform, 48hr trend, 200 Cases
800x600
10,4" TFT
ECG, SpO2, NIBP, 2xTemp., Opt.: 2xIBP, CO2
Goldway/Philips
BM3 Plus - Market Comparison
Screen
Measurements
Vendor
Design
37
Battery(2hr)
2 year
4.6kg
No
RS232, Nurse Call
Thermal (72mm)
24hr trend
800x600
10.4" TFT
12CH ECG, SpO2, NIBP, Temp. Opt.: EtCO2
Schiller
Argus LCM
Li-ion(4hr)
2 year
3.1kg
Yes
LAN, HL7 format
strip recorder (Option)
96hr trend
800x600
8.4" TFT
ECG, SpO2, NIBP, Temp.(Option)
Philips
VM4
Lead-acid(3hr)
1 year
6.3kg
Yes
LAN
Thermal (50mm)
12hr trend
640x480
10.4" TFT
3lead ECG, SpO2, NIBP, Temp.
Philips
C3
38
39
G
Bionet Patient Monitor Item List
BM3 Plus
(Item Code: BM3 Plus)
Multi-parameter Vital Signs Monitor (ECG, SpO2, NIBP, Resp, Temp*) * Temperature Probe is an additional cost option.
8.4" High Resolution TFT Screen, 58mm built-in Printer, Built-in Rechargeable Battery, 120 hours Memory Capacity, 4 Traces, Individual Sweep Speed per Parameter, 20 x 10sec alarms saved and Two Display Modes Includes: BM3 Plus Main Unit, 3 Lead ECG Cable(Snap Type) and Extension Cable, SpO2 Adult Finger Sensor and Extension Cable, NIBP Adult Cuff(Arm circumference 25-35cm) and Extension Tube, Chart Paper(x2), Power Adaptor & Hospital Grade Power Cord, Operation Manual and 3 Year Warranty Card. Option: Temperature Probe(Skin or Rectal) and 5 Lead ECG Cable
Accessories and Supplies (90 Days Warranty) Item Code(Part No.)
B-CBL-N B-CBL5-N B-WIRE-SA B-WIRE5-SA B-SPCBL-N B-SPO2-FA B-SPO2-V B-NBPCBL B-ACUFF-L B-ACUFF B-CCUFF B-PCUFF B-ICUFF TEM-PRV-R TEM-PRV-S BM-BAT-4 TRANS PC-A
Item(Part) Description
3 Lead ECG Extension Cable 5 Lead ECG Extension Cable 3 Lead ECG Cable (Snap Type) 5 Lead ECG Cable (Snap Type) SpO2 Extension Cable SpO2 Adult Finger Sensor SpO2 Multi-Site Y Sensor NIBP Extension Tube NIBP Adult Cuff Large (Arm Circumference : 31 to 40 cm) NIBP Adult Cuff (Arm Circumference : 23 to 33 cm) NIBP Child Cuff (Arm Circumference : 18 to 26 cm) NIBP Pediatric Cuff (Arm Circumference : 12 to 19 cm) NIBP Infant Cuff (Arm Circumference : 8 to 13 cm) Temperature Probe (Esophageal/Rectal Type) Temperature Probe (Skin Type) BM series Rechargeable Battery Power Transformer (DC Adaptor) Hospital Grade Power Cable
Disposable Accessories and Supplies (No Warranty) Item Code(Part No.)
B-ME-S B-SPO2-FAD B-SPO2-FND G B-NCUFF1 B-NCUFF2 B-NCUFF3 B-NCUFF4 B-NCUFF5 BM-PP
Item(Part) Description
ECG Monitoring Electrode Snap Type (30 Electrodes/Pouch) SpO2 Adult Finger Sensor Disposable SpO2 Neonate Finger Sensor Disposable NIBP Neonate Cuff #1(Arm Circumference : 3.4 to 6.3 cm) NIBP Neonate Cuff #2(Arm Circumference : 4.6 to 8.5 cm) NIBP Neonate Cuff #3(Arm Circumference : 5.8 to 10.8 cm) NIBP Neonate Cuff #4(Arm Circumference : 7.0 to 13.0 cm) NIBP Neonate Cuff #5(Arm Circumference : 8.2 to 15.3 cm) BM Paper (10 rolls/box)
Other Accessories Item Code(Part No.)
40
BM-CART G
Item(Part) Description BM Series Rolling Cart (90 Days Warranty)
Bionet Fetal Monitors
Sales Notes Fetal Monitors
Bionet Fetal Monitors
What does a Fetal Monitor do? A fetal monitor is a machine used to monitor the condition of the fetus by measuring and recording; fetal heart rate(FHR), fetal movement (FM) and uterine contractions (UC) simultaneously.
41
Bionet Fetal Monitors
What parameters are detected? FHR(Fetal Heart Rate) : FHR is detected by using an Ultrasound transducer. The movement of the fetal heart affects the frequency of the reflected ultrasound. FHR is calculated from this reflected ultrasound and usually used to monitor the oxygen delivery status. UA(Uterine Activity) : UA is detected by a TOCO transducer which has a pressure sensor inside. UA is used to monitor the interval , period, and intensity of uterine contraction. UA may be called UC(Uterine Contraction) FM(Fetal Movement) : FM is detected by an Ultrasound transducer . The movement of the fetus’ body affects the frequency of the reflected ultrasound. FM is calculated from this reflected ultrasound and usually used to evaluate Fetus Status during NST(Non-Stress Test)
FHR trace
FM trace UA trace
Z
Bionet Fetal Monitors
FC 700 Cost-Effective Fetal Monitor for Single Fetus • Clear signal quality • Automatic fetal movement detection • Easy-to-read full size chart paper • Quick & easy operation
42
Bionet Fetal Monitors
Why FC700? 1. 3 Year Warranty! 2. Superior Design & Portability! 3. Features! 4. Customer Service! 5. Complete & Ready To Use Out of the Box!
Bionet Fetal Monitors
2. Superior Design & Portability Large Character Display Fetal Heart Rate, Uterine Contraction, Fetal Heart Beat One-touch Operation Volume Up/Down UC Reference Zeroing Alarm On Start Recording Built-in Full-size thermal printer Plain thermal fax paper can be used 43
Bionet Fetal Monitors
3. Features Functions and quality •
Water-tight & Robust Probes
•
Extreme ultrasound sensitivity
•
Automatic fetal movement detection
•
FHR high/low alarm function
Special benefits •
Simple to read signal report on full-size format
•
Cost-effective
User friendly interface
Bionet Fetal Monitors 44
•
Simple setup mode
•
Trouble free operation
3. Features 3.1. Extreme ultrasound sensitivity - 1Mhz Æ Do you know the difference between 1Mhz and 2Mhz?
1Mhz
2Mhz
Benefits of 1Mhz ;
Risk factors of 2 Mhz ;
Accurate FHR detection Continuous FHR traces Reduced noisy or false signal
Inaccurate FHRs Noisy signals Detection of the MHR as the FHR
Bionet Fetal Monitors
3. Features 3.2. Simple to read signal report on full-size paper ᐭ FHR signal trend ᐮ Fetal movement (Auto, Event Marker)
ྙ
ᐯ UC trend + FM intensity ᐰ Parameters Date, Time
ᐮ ᐯ
Probe (FHR,UC) status Alarm status Printing speed, Contrast, grid Movement on/off
ᐰ Easy-to-file with perforated line
Bionet Fetal Monitors
3. Features 3.3. Control Panel UC zero reference
FHR volume ؼvolume adjustment (0~7)
ؼShort press; Adjust UC value to 10
ؼchanges the values in setup mode
ؼLong press; enter record setup mode Setup Mode 1. Printer speed 2. Print grid 3. Print contrast 4. Auto period 5. Fetal Movement
Alarm setup ؼShort press-> Alarm on/off
Record
ؼShort press->start/stop recording
ؼLong press->alarm/time setup
ؼLong press->faster printout
ؼExit the setup mode without saving
ؼExit the setup mode and save
10
45
Bionet Fetal Monitors
3. Features 3.4. Watertight & Robust Probes
Passes the drop test from 5 feet on to cement floor Passes the water protection test under 30cm of water 9-crystal ultrasound probe : Wide and high sensitive
Bionet Fetal Monitors
4. Customer Service ̶ High level of customer satisfaction:
People like our products & service staff
̶ Complimentary telephone based training & ongoing technical support
̶ No nonsense support and service ̶ US based technical support – no language/accent issues
46
Bionet Fetal Monitors
5. Complete & Ready To Use Out of Box ̶ 1 Ultrasound Probe & 1 TOCO probe ̶ 1 Event Marker ̶ Ultrasound Gel ̶ 2 belts ̶ 2 rolls of archival thermal paper ̶ Hospital Grade Power Cord The only thing we don’t supply is the patient!
Bionet Fetal Monitors
FC 1400 Bionet’s Advanced Fetal Monitor for twin fetuses with Color LCD Screen & Data Saving • 5.7” color LCD display • Twin FHR on-screen Trace • 12hour data memory • 2 types(A4/B5) paper size • High-speed printout of saved data 47
Bionet Fetal Monitors
Why FC 1400? 1. 3 Year Warranty! 2. Superior Design & Portability! 3. Advanced Features! 4. Customer Service! 5. Complete & Ready To Use Out of the Box!
Bionet Fetal Monitors
2. Superior Design & Portability Metal Stand for mounting probes
5.7” Color LCD Rechargeable battery for portability
Hand Grip
Built-in A4 and B5 size thermal printer Thermal fax paper can be used 48
Watertight and Robust Probes
Bionet Fetal Monitors
3. Features Easy to read data display •
5.7” color LCD viewer
•
Twin capability and automatic fetal movement
•
12-hour memory capacity
•
Easy on-screen access with scrolling function
Extreme data accuracy and access •
High Speed printout of stored data
•
Easy-to-read A4 & B5 size chart paper
•
Durable watertight probes
Bionet Fetal Monitors
3. Advanced Features 3.1. Screen configuration FHR Trend Graph Window US1 FHR US2 FHR
(+20) means 20 is added to real FHR to avoid overlapping
UC or TOCO
(10) means reference is set to 10
Fetal Movement Intensity Graph (US1, US2)
Uterine Contraction Intensity Graph 49
Bionet Fetal monitors
3. Advanced Features 3.2. Screen configuration (Detailed)
Bionet Fetal Monitors
3. Advanced Features 3.3. Change Alarm Range and Configuration
Use only the trim knob to navigate and change the settings values !!!
50
Bionet Fetal Monitors
3. Advanced Features 3.4. Quick Operation Control keys
Frequently using functions
YX
Bionet Fetal Monitors
3. Advanced Features 3.5. Printout (Single Fetus)
FHR detected from US1 probe After fetal movement, FHR is increased
US1 probe is used Fetal Movement from US1 probe Uterine Contraction detected from TOCO probe
51
Bionet Fetal Monitors
3. Advanced Features 3.6. Printout (Twin Fetus)
Thin FHR trace is for US1 Thick FHR trace is for US2
Fetal Movement from US1 probe Fetal Movement from US2 probe Uterine Contraction detected from TOCO probe
Bionet Fetal Monitors
4. Customer Service ̶ High level of customer satisfaction:
People like our products & service staff
̶ Complimentary telephone based training & ongoing technical support
̶ No nonsense support and service ̶ US based technical support – no language/accent issues
52
Bionet Fetal Monitors
5. Complete & Ready To Use Out of Box ̶ 2 Ultrasound Probes & 1 TOCO probe ̶ 1 Event Marker ̶ Ultrasound Gel ̶ 3 belts ̶ 2 rolls of archival thermal paper ̶ Hospital Grade Power Cord The only thing we don’t supply is the patient!
53
Thermal (210mm)
no
FHR/TOCO Parameter
LED Display
Single FHR UC Automatic FM
Bionet
FC 700
RS232/RS485
Thermal (112mm)
no
FHR/TOCO Parameter
LED Display
Single FHR UC Automatic FM
EDAN
Cadence Basic
CIS
2xSerial
Thermal (150mm)
no
FHR/TOCO Parameter
LED Display
Single FHR UC Automatic FM
GE
Corometric 171
1 year
Remote Obstetric Management s/w
Modem, PC interface
Thermal (150mm)
6hr
FHR, TOCO Trace Display
Mono Graphic LCD
Single FHR UC Automatic FM
Wallach/Huntleigh
Sonicaid Team Standard
Ni-MH(3hr)
1 year
no
no
Thermal (112mm)
no
320x240
Mono Graphic LCD
Single FHR UC
Nicolet
VersaLab APM
no
2 year
PC software
Serial
Termal (150mm)
no
FHR/TOCO Parameter
LED Display
Single FHR UC Automatic FM
Huntleigh
Baby Dopplex 3000
FC 700 - Market Comparison
RS232
Insight
1 year
no
Features \ Model
Measurements
no
2 year
no
Design
Screen
3 year
no
Warranty
Central Monitoring System
Networking
Printer
Data Saving
Vendor
Display / Resolution
no
Rechargeable Battery
54
55
Rechargeable Battery
Warranty
Ni-MH(2hr)
3 year
NO
PC Software
Li-ion(4hr)
2 year
Insight
RS232/RS485
Thermal (112mm)
Thermal (150mm or 210mm)
RS232
12hr
320x240
12hr
Networking
Printer
Data Saving
320x240
Display / Resolution
5.7", Mono
Li-ion(4hr)
2 year
1 year
no
2 year Rechargeable (4hr)
CIS
FETALGARD View PC s/w MFM-CNS
Serial
PC interface
RS232 Ethernet
Thermal (150mm)
no
1 year
Remote Obstetric Management s/w
Modem, PC interface
Thermal (150mm)
6hr
FHR, TOCO Trace Display
FHR/TOCO Parameter no
Mono
Dual FHR UC Automatic FM
Wallach/Huntleigh
Sonicaid Team Duo
LED Display
Thermal (150mm)
12hr
320x240
Back-lit LCD
Dual FHR UC Automatic FM
GE
Corometric 172
Thermal (150/152mm)
24hr
800x600
10.4", Color
Dual FHR UC
Dual FHR UC Automatic FM IUC, FECG
Dual FHR UC Automatic FM
Dual FHR UC Automatic FM
5.7", Color
SummitDoppler
FetalGard Lite
EDAN
F6 Dual F.M.
EDAN
Cadence II
Bionet
FC 1400
Screen
Measurements
Vendor
Design
Features \ Model
FC 1400 - Market Comparison
Ni-MH(3hr)
1 year
no
no
Thermal (112mm)
no
320x240
Mono
Dual FHR UC
Nicolet
VersaLab APM2
56
57
58
59
FC 700 Quick Guide
60
FC 1400 Quick Guide
G
Bionet Fetal Monitor Item List FC 700
Cost-Effective Single Fetus Monitor
(Item Code: FC 700) G
Cost-Effective Single Fetus Monitor. Combining high functionality and user friendliness, the FC 700 fetal monitor allows for comprehensive assessment of the well being of a single fetus. Includes: FC 700 Main Unit, US Probe, TOCO Probe, Event Marker Jack, Ultrasound Gel, Probe Belt(x2), Paper(x2), Power Adaptor & Hospital Grade Power Cord, Operation Manual and 3 Year Warranty Card.
TwinView FC 1400
Color LCD Twin Fetus Monitor
(Item Code: FC 1400)
Twin Fetus Monitor with Color LCD. Twin View detects and displays twin fetus heart rates and uterine activity in real time on the color LCD monitor. Includes: FC 1400 Main Unit, US Probe(x2), TOCO Probe, Event Marker Jack, Ultrasound Gel, Probe Belt(x3), Paper(x2), Power Adaptor & Hospital Grade Power Cord, Operation Manual and 3 Year Warranty Card. G
Accessories and Supplies (90 Days Warranty) Item Code(Part No.)
FC-US07 FC-TC07 FC-US14 FC-TC14 FC-EM FC-MS FC-BELT TRANS PC-A
Item(Part) Description
US Probe 700 TOCO Probe 700 US Probe 1400 TOCO Probe 1400 Event Marker Jack Metal Stand Probe Belt Power Transformer (DC Adaptor) Hospital Grade Power Cable
Disposable Accessories and Supplies (No Warranty) Item Code(Part No.)
FC-GEL FC-PP07 FC-PP14
Ultrasound Gel FC 700 Paper (10 rolls/box) FC 1400 Paper (10 rolls/box)
Item(Part) Description
Other Accessories Item Code(Part No.)
FC-CART
Item(Part) Description
FC Series Rolling Cart (90 Days Warranty)
G
61
62
63
Bionet America, Inc. 2691 Dow Ave. Ste B Tustin, CA 92780 Tel: 714.734.1760 Fax: 714.734.1761
[email protected] [email protected] www.bionetus.com