Medium Static Pressure

   EMBED


Share

Transcript

220-240V ~ 50Hz 1Ph 380-420V ~ 50Hz 3Ph Slim Line Ceiling Concealed Ducted Split Systems Green Medium Static Pressure Ducted Split System Heat Pump 12 - 18 - 24 - 30 - 36 - 48 - 60 DC Inverter R-410A Inverter Technology $ Refrigerant Leak Detection Anti Freezing Anti-Freezing Protection Easy Flexible Installation High Temp. Protect High Temp. Protection Easy Fast Service & Maintenance Auto Restart Function Cold Draft Protection Washable Air Filter 3 Minutes Time Delay Defrost Protection Durability Self diagnostic function Hydrophilic Aluminum Fins Independent Dehumidification Inverter Compressor Super Quiet ECO Function Medium Static Pressures Wired Control Timer Functions Fresh Air Efficient Fans Wireless Control Slim Design Efficient Coils Display Panel Inner Groove Copper Tubing Refrigerant HFC R410A IAQ Optional Drain Pump Efficient Operation Efficient Anti-dust Filters 40~100 Pa Auto Auto Fan Speed Auto Mode 3 Min. Ducted Split Systems Green Medium Static Pressure Key Features Heat Pump medium static pressure, slim line, ceiling concealed ducted split is the optimum air conditioning solution for places which require ceiling installation above false ceiling and minimum sound levels. Its slim profile and flexible installation make this system the best choice for residential and light commercial applications where the units are practically hidden from view. Healthy & Clean Indoor Air Quality (IAQ) IAQ The indoor unit is fitted with a fresh air knock out panel that can be utilized to introduce fresh air into the room. This helps prevent the build of stale air and enhances air quality in working environments and enclosed applications without natural fresh air supply. SMART CONTROLS Modern Slim Design Compact invisible indoor unit with ultra slim profile and low height is just 21 cm for sizes 12K-18K, 24.9 cm for sizes 30K-36K and 30 cm for sizes 42K-48K-60K suitable for low false ceiling applications. Wired room controller ( option ) Wireless Remote control Smart LED display panel shows control functions and also shows error code in case of a malfunction. EFFICIENT, TROPICAL & QUIET Efficient Tropical Operation with Minimum Electrical Consumption works with the new R-410A refrigerant which increases its energy efficiency and does not degrade the ozone layer. $ Patented heat transfer and aerodynamics technologies to ensure prefect operation up to 52°C outdoor ambient temperature for energy saving and low operating cost. OUTDOOR UNIT 2 Sizes : 30 - 36 Sizes : 48-60 Patented centrifugal blower, elephant ear propeller, new heat exchangers, improved Air Management System (AMS), and quiet compressor. Statically and dynamically balanced fans for quiet operation. Minimum vibrations with strengthened sheet metal parts by finite element analysis. R-410A HFC Standard Smart Wired Controller with complete control functions built in the control system. Wired Controller can be fixed on the wall and avoid mislaying. It’s mainly used for commercial zone and makes the control more convenient. Standard Smart LCD infrared wireless remote control with complete control functions built in the control system to ensure efficiency at all operating conditions. Optional Smart Link central Control to monitor from a center point, the operation of number of ducted indoor units in the same project site. This feature is particularly helpful in large office applications and hotels. Auto fan speed which changes automatically the fan speed to high or medium or low fan speed by sensing the temperature difference between the room temperature and setting temperature. Auto mode which changes automatically the operation mode and capacity output according to temperature difference between room temperature and setting temperature. Independent Dehumidification mode which dehumidifies the room efficiently, but not lower the temperature so obviously as cooling operation. ECO function for energy saving and comfortable healthy sleep which automatically changes fan speed to low speed and controls both setting and room temperatures. $ Programmable timer for easy on and off selection with energy savings including off timer, on timer, off/on timer and on/off timer functions. Superior air distribution performance : Three fan speeds with external static pressure up to 40 ~ 100 Pa as per the model to satisfy air flow and static pressure requirements to suit various applications. 40~100 Pa Efficient Air Management System (AMS) leading to maximum air flow with minimum turbulence for minimum air resistance, smooth airflow and efficient operation. AMS Follow Me function for smart wired control of comfortable temperature. With this technology, an efficient temperature sensor is built in the wired control just like the air conditioner is following wired control. Durability Carrier innovative outdoor axial fan technology for efficient operation with minimum air resistance and maximum air flow. Anti-rust, weather proof and long life indoor unit sheet metal parts made of chemically treated and zinc coated ( galvanized ) sheet metal. Carrier innovative double inlet, double width forward curved centrifugal blower technology driven by 3 speeds high efficiency motor of low power consumption . Drain pan is designed to protect against rust, to minimize wet surface and residual water during off cycles and to inhibit bacteria growth that may cause smells. Efficient indoor and outdoor coils with large heat transfer surfaces for minimum electrical consumption. Efficient trapeziform Inner groove copper tubing compared with traditional copper tubing, it allows more refrigerant flow, improvs heat exchange efficiency and lowers power consumption while keeping the same capacity output level. Precoated Hydrophilic Aluminum Fins of indoor coil to protect the coil against corrosion and to allow easy and quick removal of unrestricted condensate water between the coil fins to increase airflow, improve heat exchange efficiency and accelerate cooling process. Auto restart function with backup memory. When the power failure happenes during the operation of air conditioner, the microprocessor of the Printed Circuit Board will memorize the operation setting. After the power is recovered, the air conditioner operates automatically ( without remote control but after elapse of compressor safety time delay ), according to the previous operation settings. Anti-rust, weather proof and long life outdoor unit sheet metal parts made of chemically treated and zinc coated ( galvanized ) sheet metal. Powder painted casing of outdoor unit with prefect adhesion of highly resistant ployester paint 60-80 microns thick, which is electro-statically applied and baked at a temperature of 220°C. Optional coated aluminum fins of outdoor coil for coastal applications to protect against corrosion. Smart Link Auto 3 (three) minutes safety time delay between compressor turning off and turning on for compressor protection against cycling. 3 Min. Anti-freezing protection of indoor coil when the air conditioner is operating in cool mode with excessive dirt on the indoor coil and / or clogged air filters and / or low ambient temperature operation of cool mode. Anti Freezing High temperature protection of outdoor coil when Hi Temp. Protect the air conditioner is operating in cool mode. This protection is only available for heat pump system. Cool Cold draft protection when the air conditioner is operating in heat mode to prevent cold air blowing out at the beginning of heat mode which avoids the discomfort to the user. High temperature protection of indoor coil when the air conditioner is operating in heat mode. Hi Temp. Protect Heat Defrost protection of outdoor coil when the air conditioner is operating in heat mode at very low ambient temperature. Smart self-diagnostic function for malfunctions detection for easy fast service and maintenance. Smart Refrigerant leak detection by sensitive sensors mounted on both indoor and outdoor coils for easy fast service and maintenance. Auto reset – internal thermal protector of indoor and outdoor fan motors to protect motor windings against excessive current. Motors The components of both indoor and outdoor units comply with international standards of performance and safety. Rev. (0) - 2017 www.carrierafrica.com Sizes : 12-18-24 Complete Safety & Reliability Functions Comfort with Complete Control Functions KEY FEATURES Efficient anti dust washable aluminim air filters for clean and healthy air. Quiet with Minimum Sound Level Ducted Split Systems Green Medium Static Pressure Key Features Key Features Easy Installation, Service and Maintenance (Cont.) Easy Installation, Service and Maintenance Due to compact dimensions, low height and low weight, the installation of ducted indoor unit on the ceiling is faster and extremely easy. The display panel can be installed on the false ceiling to show unit operation and error code. Easy removal of washable air filters for cleaning. Slim Low Height Compact Dimensions & Light Weight Size W 12K 70 18K 88 24K 111 30K 36K 48K 60K Net Weight Dimensions (cm) 136 H D 21 67.4 18.5 23 30.2 24.9 120 30 77.4 Min. 5mm Kg 21 cm or 24.9 cm or 30 cm Remote ON / OFF Drop - Ceiling 40.5 87.4 Remote ON / OFF function provides more easy central control of ducted split system. Easy accessibility to motors and fans of indoor unit for easy fast service and maintenance. 46 Flexible two directions of air return : Back air return ( factory standard ) Bottom air return ( can be done at field ). Pre-Punched Fresh air intake built in the indoor unit from both sides to make air quality more healthy and more comfortable. motor Blower housing Remote system alarm function which required for some applications such as computer rooms for fast and easy service and maintenance. Bottom Panel Remote Alarm Smart self-diagnostic function for malfunctions detection through the leds of display panel for easy fast service and maintenance. Back Return Air Bottom Return Air Optional drain pump which can lift the condensate water up to 75 cm upmost. Optional drain pump is factory installed. Smart Refrigerant leak detection by sensitive sensors mounted on both indoor and outdoor coils for easy fast service and maintenance. 75 cm ceiling Rev. (0) - 2017 www.carrierafrica.com Indoor unit equipped with flange connections for both supply and return air ducts. Fresh air intake 3 Ducted Split Systems Green Wired Room Controller Medium Static Pressure 1 POWER Button 2 MODE Selection Button 3 Temperature Selection Button 4 FAN SPEED Selection Button 5 FOLLOW ME Button TIMER Button 7 DELAY / DAY OFF Button 8 CONFIRM Button 9 BACK Button Auto Cool 2 Heat Fan SU MO TU WE TH FR SA Week Day On Off 3 2 4 MODE FAN SPEED 6 5 SWING SWING FOLLOW ME 7 10 DELAY/DAY OFF CONFIRM BACK Dry Fan 2 Fan speed Indicator Low Fan Speed Indicator Medium Fan Speed Indicator 1 3 Faceplate function indicator 4 Follow me function indicator 5 C° / F° indicator 6 Temperature display 10 14 13 MED 5 6 7 8 Heat Fan SU MO TU WE TH FR SA 11 TIMER DELAY/DAY OFF 9 Day On Off 1 2 3 4 MODE Week 10 FAN SPEED 7 Lock indicator 8 Room temperature indicator 9 SWING Clock display SWING FOLLOW ME 1 Signal transmission indicator 2 MODE indicator AUTO Automatic COOL Cooling DRY Dehumidification only HEAT Heating 3 ON / OFF indicator 4 SET TEMP. indicator 5 FAN SPEED indicator LOW FAN SPEED indicator LOW 2 Decrease temperature button The set temperature is decreased down to 17°C. HIGH FAN SPEED indicator HIGH 3 Increase temperature button The set temperature is increased up to 30°C. 4 FAN selection button Low - Medium - High - Auto fan speed 5 ON/OFF button 6 Air Direction function button * 7 Vertical Air Flow Auto Swing * 8 Sleep function button 9 TIMER ON function button 10 TIMER OFF function button 11 My Mode function button to memorize the preferred settings 12 Follow Me function button * 11 Timer display 13 LED Display function button 14 TURBO function button * COPY 67 8 MODE selection button AUTO - COOL - DRY - HEAT - FAN On/Off timer BACK 4 LOW 1 10 CONFIRM TIMER ON OFF 5 FAN Ventilation (fan only) Control Buttons 4 Auto Cool Dry Auto Auto 3 DRY 2 Note : * This function does not work with this product but works with other products MED FAN SPEED indicator MED AUTO FAN SPEED indicator AUTO 6 TIMER ON function indicator 7 TIMER OFF function indicator 8 FOLLOW ME function indicator Rev. (0) - 2017 www.carrierafrica.com 2 POWER High Fan Speed Indicator Auto Fan Speed Indicator 7 11 12 4 8 9 9 DRY Mode Indicator FAN Mode Indicator 3 FAN HIGH COPY 8 AUTO Mode Indicator Heating Mode Indicator 2 5 1 6 SET TEMP. COOL HEAT Operation Mode Indicator COOL Mode Indicator 3 AUTO Auto Cool Dry Auto Display of Wired Room Controller 1 1 1 POWER TIMER 10 COPY Button Display Of Remote Control Display of Wired Room Controller 1 2 3 4 6 Wireless Remote Control ( option ) Ducted Split Systems Green Medium Static Pressure Smart Self Diagnostic Function For Malfunction Detection Smart Self Diagnostic Function For Malfunction Detection Display of the indoor unit size 12 1 2 3 4 5 6 7 1 2 3 4 5 6 7 1 Touche d’urgence Lorsqu’on a perdu la télécommande, que celle-ci est endommagée ou que la batterie est à plat, la touche d’urgence permet de faire fonctionner l’unité. 1 Touche d’urgence Lorsqu’on a perdu la télécommande, que celle-ci est endommagée ou que la batterie est à plat, la touche d’urgence permet de faire fonctionner l’unité. 2 Led OPERATION ( fonctionnement ) * allumeé lorsque l’unité fonctionne. 2 Led OPERATION ( fonctionnement ) * allumeé lorsque l’unité fonctionne. 3 Led TIMER ( temporisateur ) * allumeé en fonction temporisateur. 3 Led TIMER ( temporisateur ) * allumeé en fonction temporisateur. 4 Led DEFROST / FAN ( dégivrage / ventilation ) Led DEFROST ( dégivrage ) : pour l’unit à pompe à chaleur. Led FAN ( ventilation ) pour l’unité à refroidissement seul. 4 Led DEFROST / FAN ( dégivrage / ventilation ) Led DEFROST ( dégivrage ) : pour l’unit à pompe à chaleur. Led FAN ( ventilation ) pour l’unité à refroidissement seul. 5 Led ALARM clignote lorsque le code défaut de l’unit extérieure est identifiable. 5 Led ALARM clignote lorsque le code défaut de l’unit extérieure est identifiable. 6 Récepteur des signaux envoyés par la télécommande 6 Récepteur des signaux envoyés par la télécommande 7 Affichage Le code de défaut est identifiable par l’affichage 7 Affichage Le code de défaut est identifiable par l’affichage Self diagnostics sizes 18-24-30-36-48-60 Self-diagnosis function of the indoor unit size 12 The fault code is identifiable by the LEDs and the fault code The fault code is identifiable by the LEDs and the fault code Malfunction Reason LED OPERATION LED TIMER LED DEF.FAN LED ALARM Malfunction Code Temperature sensor air from the indoor unit E0 Indoor coil temperature sensor of the indoor unit E1 Malfunction Reason LED OPERATION LED TIMER LED DEF.FAN LED ALARM Malfunction Code Model channel is abnormal E0 The indoor / outdoor unit communication unit E1 Temperature sensor air from the indoor unit E2 Indoor coil temperature sensor of the indoor unit E3 Outdoor unit coil temperature sensor E4 Outdoor unit coil temperature sensor E Outdoor malfunction E EEPROM malfunction E Water-level alarm malfunction E Protection against over current outdoor unit P0 EEPROM malfunction E7 Protection against high temperature compressor P1 Water-level alarm malfunction EE Outdoor unit low pressure malfunction Ed Protection against over current outdoor unit The unit is switched off by remote control Defrost heater is active = Flash 5Hz = Flash 1Hz * = LED DEFROST (defrost) for the heat pump unit Led FAN ( FAN ) for cooling only unit. The unit is switched off by remote control Defrost heater is active = Flash 5Hz = Flash 1Hz * = LED DEFROST (defrost) for the heat pump unit Led FAN ( FAN ) for cooling only unit. Rev. (0) - 2017 www.carrierafrica.com Display of the indoor unit sizes 18-24-30-36-48-60 Technical Specifications System type Heat Pump System size 12K 18K 24K 30K 36K 36K 48K 60K Indoor unit model 42QSS012NS 42QSS018NS 42QSS024NS 42QSS030NS 42QSS036NS 42QSS036NT 42QSS048NT 42QSS060NT Outdoor unit model 38QUS012NS 38QUS018NS 38QUS024NS 38QUS030NS 38QUS036NS 38QUS036NT 38QUS048NT 38QUS060NT kW 3.66 5.27 7.62 8.79 10.55 10.55 14.07 16.12 Btu/hr 12500 18000 26000 30000 36000 36000 48000 55000 Input power - Cooling W 1370 1900 2800 3300 3800 3800 5200 6200 Input current - Cooling A 6.1 9.7 13.5 16.5 18.5 6.1 9.1 10.9 W/W 2.67 2.77 2.72 2.66 2.78 2.78 2.71 2.60 Btu/wh 9.12 9.47 9.28 9.09 9.47 9.47 9.23 8.87 kW 3.81 5.57 7.91 9.67 11.14 11.14 15.53 17.58 Btu/hr 13000 19000 27000 33000 38000 38000 53000 60000 Input power - Heating W 1310 1850 2300 2900 3500 3400 4400 5200 Input current - Heating A 5.8 7.9 11.3 15.0 17.3 5.6 7.7 9.1 W/W 2.91 3.01 3.44 3.33 3.18 3.27 3.53 3.38 42QSS012NS 42QSS018NS 42QSS024NS 42QSS030NS 42QSS036NS 42QSS036NT 42QSS048NT 42QSS060NT m3/hr 625/485/400 950/770/670 cfm 369/287/236 561/455/396 773/661/546 885/767/590 1062/826/620 1062/826/620 Indoor maximum external static pressure Pa 25 25 25 37 37 37 50 50 Range external static pressure Pa 0-60 0-60 0-80 0-100 0-100 0-100 0-160 0-160 Sound Pressure (high/med/low) dB(A) 40/36/32 40/37/35 42/39/37 44/40/37 48/43/39 48/43/39 52/48/43 52/48/43 Net Dimensions (W×H×D) mm 700x210x635 880x210x674 1100x249x774 1100x249x774 1100x249x774 1100x249x774 1200x300x865 1200x300x865 Weight Net Kg 19.2 23.7 30.8 32.2 32.2 32.2 44.5 47 38QUS012NS 38QUS018NS 38QUS024NS 38QUS030NS 38QUS036NS 38QUS036NT 38QUS048NT 38QUS060NT Rotary Rotary Rotary Rotary Scroll Scroll Scroll Scroll Cooling capacity E.E.R. - Cooling Heating capacity C.O.P - Heating Indoor unit model Nominal air flow (high/med/low) ( @ rated external static pressure ) Outdoor unit model Compressor type 1310/1120/925 1500/1300/1000 1800/1400/1050 1800/1400/1050 2300/1850/1400 2300/1850/1400 Refrigerant type / Coupler 1357/1092/826 1357/1092/826 R410A / Flare Sound pressure dB(A) 59 61 61 62 63 63 64 65 Net Dimensions (W×H×D) mm 770x555x300 770x555x300 845x702x363 946x810x410 946x810x410 946x810x410 900x1170x350 900x1170x350 Weight Net kg 34 36.5 52.7 65 79.5 74.5 93.2 97 Liquid Φ6.35 ( 1/4” ) Φ6.35 ( 1/4" ) Φ9.52 ( 3/8" ) Φ9.52 ( 3/8" ) Φ9.52 ( 3/8" ) Φ9.52 ( 3/8" ) Φ9.52 ( 3/8" ) Φ9.52 ( 3/8" ) Gas Φ12.7 ( 1/2” ) Φ12.7 ( 1/2" ) Φ15.9 ( 5/8" ) Φ19.0 ( 3/4" ) Φ19.0 ( 3/4" ) Φ19.0 ( 3/4" ) Φ19.0 ( 3/4" ) Φ19.0 ( 3/4" ) Maximum pipe length m 15 25 25 30 30 30 50 50 Maximum height difference m 8 15 15 20 20 20 30 30 V/ph/Hz 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 220-240/1/50 380-415/3/50 380-415/3/50 380-415/3/50 Installation Data Pipe connection sizes ( inch ) Rev. (0) - 2017 Power supply * Cooling Capacity and Energy Efficiency Ratio (EER) based on ISO 13253 Standard at conditions : 35/24ºC db/wb ambient Temperature. 27/19ºC db/wb Indoor Temperature. 220 volts power supply (for sizes 12-18-24-30-36) Single Phase. 380 volts power supply (for sizes 36-48-60) Three Phase. * Heating Capacity and Coefficient Of Performance (COP) are based on ISO 13253 Standard at operating conditions : 20/15ºC db/wb Indoor Temperature 7/6ºC db/wb Outdoor Temperature. 220 volts power supply (for sizes 12-18-24-30-36) Single Phase. 380 volts power supply (for sizes 36-48-60) Three Phase. * Sound pressure is measured in anechoic chamber based on GB/T7725 Standard * Carrier is committed to continuously improving its products according to national and international standards to ensure the highest quality and reliability standards, and to meet market regulations and requirements. All specifications subject to change without prior notice according to Carrier policy of continuous development. High Air Flow High Air Flow