Preview only show first 10 pages with watermark. For full document please download

Megaline®, Gigaline® And Varioline

   EMBED


Share

Transcript

MegaLine®, GigaLine® and VarioLine® Copper and Fiber Optic Cabling Systems for DataCenter · Office · Industry The Quality Connection 2 Portfolio Strong brands, strong service Datacom system families: a sound, future-proof investment MegaLine® VarioLine® GigaLine® Copper cabling systems Modular system peripherals* FO cabling systems MegaLine® Cu data cables * VarioLine® can be used for both system families GigaLine® FO data cables MegaLine® GigaLine® FO connectivity Connect Cu connectivity GigaLine® VarioKeystone® FO patch cords/ trunk cables Cu connectivity MegaLine® Cu patch cords/ trunk cables LEONI organises its range of data communications products for the passive cabling infrastructure in buildings and local networks into three main groups: n Copper cabling systems MegaLine® n Fiber optic cabling systems GigaLine® n Modular system peripherals VarioLine® MegaLine® from LEONI is a copper system family for all classes and categories that delivers a sound, future-proof investment. It incorporates MegaLine® Copper data cables, patch cords and trunk cables as well as MegaLine® Connect and VarioKeystone® Connectivity. GigaLine® allows extremely high bandwidths and long transmission distances thanks to its fiber optic technology. GigaLine® Fiber optic data cables, patch cords and trunk cables as well as GigaLine® Connectivity combine to produce an extremely efficient system. VarioLine® is a modular consolidation point and underfloor range. All connection components can be easily and quickly integrated into different areas of application and adapted to local conditions. LEONI also offers a comprehensive service package comprising data sheets, announcement texts, seminars and certification Issue: November 2012 © LEONI Kerpen GmbH The contents of this catalogue are protected by copyright. All rights reserved. All necessary planning documents can be found on the Internet: www.leoni-infrastructure-datacom.com We reserve the right to make technical modifications; typographical errors and mistakes excepted. programmes. www.leoni-infrastructure-datacom.com 3 Contents Page n MegaLine® Copper (Cu) 10 Cu data cables n VarioKeystone® 72 Cu connectivity Cabling systems n MegaLine® Connect45 92 Cable and connectivity Cu connectivity n ELine 1200® EC7 104 Cu connectivity n MegaLine® 116 Cu patch cords/trunk cables n GigaLine® Fiber optic (FO) n GigaLine® n GigaLine® Cable and connectivity for copper and FO 210 FO patch cords/trunk cables n GigaLine® 182 FO connectivity Cabling systems System peripherals 152 FO data cables 228 DataCenter links n VarioLine® 236 Modular system peripherals • Consolidation points (CP) • Underfloor solutions (UF) n Office 264 Fields of application www.leoni-infrastructure-datacom.com n Industry 266 n DataCenter 272 4 Welcome to the datacom mega store for cable and system solutions LEONI is a leading supplier in the market for structured cabling systems. In addition to cabling for offices (LAN Office), the range also includes cabling for industrial complexes (LAN Industry) and DataCenter infrastructure (DataCenter). LEONI's services range from producing our own fibers, manufacturing data cables in copper and fiber optic technology, pre-assembled patch cords and trunk cables as well as connection components through to complete cabling systems. Everything from a single source LEONI's range of copper cable and connectivity offers futureproof cabling systems for building, floor and workstation cabling. Fiber optic cable and connectivity is the first choice wherever broadband data transmission in combination with long transmission distances in a LAN or MAN are required. LEONI's GigaLine® fiber optic cables and GigaLine® fiber optic connectivity offer high-speed data highways for backbone networks. LEONI products and solutions are ideal for applications which demand maximum reliability, quality and durability, even under harsh and adverse conditions. www.leoni-infrastructure-datacom.com 5 Application Office Industry DataCenter European standards EN 50173-2 EN 50173-3 EN 50173-5 International standards ISO/IEC 11801 ISO/IEC 24702 ISO/IEC 24764 The cabling systems exceed all relevant European (EN 50173) and international standards (ISO/IEC 11801) and are designed for key applications (Office · DataCenter · Industry). www.leoni-infrastructure-datacom.com 6 The LEONI Group Cable expertise for the most varied industrial markets LEONI is a leading supplier of cable systems and related Your markets – our strength services for the automotive industry and various other As diverse as our product and service range are the markets and industrial sectors. sectors LEONI is supplying. We focus our activities on customers in the fields of Automotive & Commercial Vehicles, Industry Our group of companies employs more than 63,000 people in & Healthcare, Communication & Infrastructure, Electrical 31 countries. Corporate vision, highest quality and innovative Appliances and Conductors & Copper Solutions. power have made us one of the leading cable manufacturers in Europe. LEONI develops and produces technically sophisticated We are among the leading European suppliers in the Communi- products ranging from wire and optical fibers to cables cation & Infrastructure market to which at LEONI as a cable through to complete cable systems and also offers the related manufacturer also belong activities in the fields of infrastructure services. Moreover, the product portfolio comprises strands, & data communications, industrial plant projects, solar- and standardised cables, hybrid cables, glass fiber as well as special wind power, energy & telecommunications, irradiation cross- cables, cable harnesses, wiring systems components and linking and transportation engineering. Our customers benefit fully assembled systems for applications in various industrial world-wide from innovative as well as reliable and long-lasting markets. products of high quality. LEONI – we create the best connection for your future. for further informations www.leoni.com Engineering Products and services portfolio at a glance Services Cable systems/Wiring systems Cable harnesses Copper cables Wires and strands Sensors Hybrid cables Optical fibers Relay and safety systems Optical cables Connectors LEONI's core markets Automotive & Commercial Vehicles Industry & Healthcare Communication &  Infrastructure Electrical Appliances Conductors & Copper Solutions www.leoni-infrastructure-datacom.com 7 Infrastructure & Datacom Business Unit Trust the best partner for your requirements. Infrastructure & Datacom Business Unit Datacom LEONI brings together the expertise for power and The extensive know-how of all companies belonging to the communications networks in public buildings, in structural LEONI Group and the unique range of products and services they and civil engineering, in offices, in DataCenters and in industry. offer are concentrated in the Datacom business unit. Some of the companies involved have been working successfully in the field Investors, integrators, planners, installers and businesses can of cable-bound networks for decades now - particularly LEONI. obtain cables, connectivity and complete cabling solutions from a single source. The range includes system solutions based The origins on copper and fiber optic technology as well as halogen-free LEONI has been working successfully in the field of cable-bound power cables with and without total system integrity. Constant networks for many years. As one of the leading manufacturers innovations in the areas of safety, environmental compatibility in the cable industry, the company has been successfully and energy efficiency offer enhanced customer benefits. Thanks meeting the complex needs of international markets for more to on-site consulting services and extensive experience, LEONI is than 90 years. The quest for constant improvement is a central an internationally recognised partner for your projects. element of the company philosophy and will continue under the new name of LEONI Infrastructure & Datacom Business Unit. And it is to the future that we look, producing high-quality, innovative cable and cabling products which are always well ahead of the standards of the time. www.leoni-infrastructure-datacom.com 8 Quality and environmental management The Quality Connection LEONI quality management LEONI environmental management One of the most important factors in the success of LEONI New environmental directives have been in force in the European was and remains the uniformly high quality of its products over Union (EU) since July 2006. EU Directive 2002/96/EC WEEE the decades. (Waste Electrical and Electronic Equipment) regulates the We pay particularly close attention to this through precise disposal of electrical and electronic equipment and components. planning, testing and documentation. Quality management for LEONI's wire and cable production facilities is certified EU Directive 2002/95/EC RoHS (Restriction of the use of certain worldwide in accordance with ISO 9001:2000. Hazardous Substances in electrical and electronic equipment ) restricts the use of certain hazardous substances in electrical and electronic equipment and components. As part of the production process, we use the latest systems Cables and wires and the associated connectivity are only to measure, monitor and regulate the diameter and insulating affected by the aforementioned directives insofar as they are capabilities of our cables and wires. The production control group an internal component of the listed devices and components. performs regular spot checks to ensure compliance with the Cables and wires and the associated connectivity therefore do required limit values. These tests are performed directly in the not fall under the aforementioned directives if they are located production area and guarantee a speedy response to interference. outside of electrical and electronic devices. This also applies By combining these quality assurance measures, we are able to connection cables, connection sockets and other peripheral to continuously optimise our ambitious quality targets. products as these are disconnected when a device is to be disposed of. www.leoni-infrastructure-datacom.com 9 All MegaLine® and GigaLine® brand data cables produced after January 1, 2006 are free from hazardous substances EU Directive 2002/96/EC as per RoHS. The associated connectivity is also free from on waste electrical and electronic equipment. hazardous substances. This is ensured in close cooperation with suppliers. EU Directive 2002/95/EC on the restriction of the use of certain This means avoiding the following substances, among others: ■■ Polybrominated diphenyl ether (PBDE) ■■ Decabromodiphenyl ether (DecaBDE) ■■ Perfluorooctane sulfonate (PFOS) ■■ Pentabromodiphenyl ether (PentaBDE) ■■ Octabromodiphenyl ether (OctaBDE) ■■ Lead (Pb) ■■ Mercury (Hg) ■■ Cadmium (Cd) ■■ Hexavalent chromium (Cr VI) ■■ Polybrominated biphenyls (PBB) hazardous substances in electrical and electronic equipment. LEONI has been operating a certified and practised environmental management system according to DIN EN ISO 14001 for the development and manufacture of cables and wires from as far back as 1989. The TÜV certification given by the German Technical Certification Association is proof of the company's environmentally friendly product design credentials. By ensuring the RoHS conformity of the data and communication cables as well as the associated connectivity, LEONI Kerpen GmbH is making a further commitment to environmental responsibility. Even though data and communication cables as well What does RoHS mean? as the associated connectivity do not fall under the RoHS stands for Restriction of the use of certain new directives, LEONI has opted to use RoHS-compliant Hazardous Substances in electrical and electronic materials. equipment. www.leoni-infrastructure-datacom.com 10 10 MegaLine® copper data cables www.leoni-infrastructure-datacom.com Office Industry DataCenter MegaLine® copper data cables Page SPACE concept 12 SPACE – Security 13 SPACE – Performance 14 SPACE – Application 16 SPACE – Construction 17 SPACE – EMC 18 Type codes 19 Cable types 20 MegaLine® copper data cables Copper data cables at a glance o o o o o o o o o o o o o o o i i i i i i i i i i o dc i www.leoni-infrastructure-datacom.com Page dc dc dc dc dc dc dc 22 MegaLine® G12-150 S/F Category "8" Class "G" 22 MegaLine® F10-130 S/F Category 7A Class FA 24 MegaLine® F10-125 S/F Category 7A Class FA 26 MegaLine® F10-115 S/F Category 7A Class FA 28 MegaLine® F6-90 S/F Category 7 Class F 30 MegaLine® E5-70 S/F Category 6A Class E A 32 MegaLine® E5-70 F/F Category 6A Class E A 34 MegaLine® E5-60 U/F Category 6A Class E A 36 MegaLine® E2-45 U/F Category 6 Class E 38 MegaLine® E2-30 F/U Category 6 Class E 40 MegaLine® E2-30 U/U Category 6 Class E 42 MegaLine® D1-20 SF/U Category 5 Class D 44 MegaLine® F10-120 S/F flex Category 7 Class FA 46 MegaLine® F6-90 S/F flex Category 7 Class F 48 MegaLine® D1-20 SF/U flex Category 5 Class D 50 MegaLine® F10-130 S/F (L)2Y Category "7A" Class FA 52 MegaLine® F10-130 S/F QH Category "7A" Class FA 54 MegaLine® F10-130 S/F Vö Category "7A" Class FA 56 MegaLine® F10-115 S/F V Category "7A" Class FA 58 MegaLine® F6-90 S/F 2Y Category 7 Class F 60 MegaLine® D1-20 SF/U 2Y Category 5 Class D 62 MegaLine® D1-20 SF/U HQH Category 5 Class D 64 MegaLine® F10-120 S/F 11Y flex Category "7A" Class FA 66 MegaLine® F6-70 S/F 11Y flex Category 7 Class F 68 MegaLine® D1-20 S/U 11Y superflex Category 5 Class D 70 Office cables DataCenter cables Industrial cables MegaLine® Cu data cables 11 12 SPACE concept Finding the right data cable S P A C E Security Performance Application Construction EMC LEONI's SPACE concept is based on a pragmatic and clearly SPACE matrix: structured matrix. This decision-making aid will help you to find the right data cable for your application faster. The concept is based on the classification of the five main selection criteria for determining the potential overall performance of a data cable: Security (fire behaviour) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Security · Performance · Application · Construction · EMC It also allows the value for money to be assessed and makes room for alternative technical and economic scenarios. The demands made on the segment in question rise in step Performance (cabling class, bandwidth) P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz with the increase in the SPACE index. Example of a data cable with the code S3 P4 A4 C5 E5 : S3 It passes the fire test according to IEC 60332-3-24 (Security Level 3) P4 It meets the minimum requirements of the new Class FA (Performance Level 4) Application (Ethernet, TV) A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV A4 It is dimensioned for applications with more than 10 GbE Construction (conductor dimensions, tensile strength) C (Application Level 4) C5 It consists of a conductor with AWG 22 (Construction Level 5) _ and thus has low attenuation values and an increased current rating E5 The coupling attenuation is ­>80 dB (EMC Level 5) With the VDE kitemark (an independent hallmark of quality including production monitoring), LEONI documents that 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) E 1 > 40 dB 2 > 50 dB it guarantees the SPACE quality features at all times. www.leoni-infrastructure-datacom.com Office Industry DataCenter SPACE concept 13 SPACE – Security As a result of the constant increase in the installed basis and MegaLine® data cables have improved fire protection the installation density, the fire behaviour of data cables characteristics: is an important safety criterion. When manufactured according ■■ ➔ Makes rescue and salvage operations easier to the legal regulations and installed correctly, data cables cannot cause a fire. If they do catch fire, however, they can Extremely low smoke development according to IEC 61034 ■■ Low toxicity (dioxins are not produced) ➔ Reduces the risk of poisoning inflame and spread the fire. ■■ Free from halogens according to IEC 60754-2 ➔N  o consequential damage to material assets as a result One of the aims here is to prevent the propagation of fire and of corrosion the resulting damage by using flame-retardant, halogen-free cable designs. ■■ Low fire load values ➔ Limits the exacerbating effects on the source of the fire ■■ High oxygen index (OI up to 45) ➔ Reduces the flammability Security (fire behaviour) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 The five security levels with regard to fire propagation/flame retardance: S 1  IEC 60332-2-2 S 4  EFP (Enhanced Fire Performance) Grade 1 Testing of the vertical propagation in a core or individual cable. In this cable bundle test, a flame is applied to the lower part Test method: incandescent flame. of the test samples on a vertical ladder with a length of S 360 cm using a high-performance burner. During and after Testing of the vertical propagation in a core or individual cable.  20 minutes, only about 1 m of the section to which the flame Test method: 1 KW flame. A flame is applied to the lower end is applied may burn. Immediately after removal of the flame, of a vertical sample of the cable with a length of approx. 60 cm the self‑extinguishing process must start. Only specially for about 60 seconds using a type of Bunsen burner. After designed data cables can stand up to this exacting fire test. 2  IEC 60332-1-2 removal of the burner, the flames must go out by themselves. The parts of the cable damaged by the flames must not reach intensive application of the flame for a test period of S 5  EFP (Enhanced Fire Performance) Grade 2 its upper end (distance: 50 mm). This stricter security level is application-specific. S Security levels Testing of the flame propagation in an arrangement of several where high and very high security measures are required cables, a so-called cable bundle, is carried out according for the protection of persons or material assets. For example to IEC 60332-3-24. In this cable bundle test, a flame is applied in hospitals, schools, hotels, airports, train stations, department to the lower part of the test samples on a vertical ladder with stores or in power stations, DataCenters, banks and insurance a length of 360 cm using a high-performance burner. During companies, alarm systems. 3  IEC 60332-3-24 and after intensive application of the flame for a test period of 20 minutes, the cables must not burn higher than 250 cm. www.leoni-infrastructure-datacom.com SS S 3, 4 and 5 are used in particular MegaLine® Cu data cables Fire behaviour 14 SPACE concept SPACE – Performance Cabling class/bandwidth Indoor cabling is expected to have a service life of 10 to 15 years. This requires far-sighted planning of the necessary performance of cabling systems and their components. The international standards have often not gone far enough Performance (cabling class, bandwidth) P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz due to the compromises struggled for and in view of the swiftly increasing transmission rates. Since the development The five classes for performance (cabling class, bandwidth) of 10 Gigabit Ethernet, none of the cabling classes below have very high reserves with regard to the standard involved. Class F can be said to meet the demands of the future. MegaLine® data cables have excellent transmission performance. They offer high security reserves and are always one step ahead of the standard. MegaLine® – an investment with a future! P 3  better than Class F (600 MHz) n Class F MHz n MegaLine® 1200 1000 800 F6-90 S/F F6-80 S/F 600 400 200 0 Example: MegaLine® F6-90 S/F better than Category 7 according to EN 50288 and IEC 61156 excellent NEXT, excellent shielding characteristics (shielding of pairs and overall shielding), low skew www.leoni-infrastructure-datacom.com Industry DataCenter SPACE concept P P 1  better than Class E (250 MHz) 2  better than Class EA (500 MHz) n Class E MHz n MegaLine® 500 800 E2-45 U/F 450 700 400 350 300 n Class E A MHz n MegaLine® E5-70 S/F E5-70 F/F 600 E2-30 U/U E2-30 F/U 500 250 400 200 300 150 200 100 100 50 0 0 Example: MegaLine® E2-45 U/F Example: MegaLine® E5-70 S/F better than Category 6 according to EN 50288 better than Category 6A according to EN 50288 and IEC 61156 and IEC 61156, very good NEXT, low skew very good NEXT, very good shielding characteristics (shielding of pairs and overall shielding), low skew P P 4  better than Class FA (1000 MHz) MHz n MegaLine® 1400 F10-130 S/F 1300 1200 5  better than Class "G" (1200 MHz) n Class FA F10-115 S/F 1100 n Class "G" MHz 1600 n MegaLine® G12-150 S/F 1400 1200 1000 800 1000 900 600 400 800 200 700 0 Example: MegaLine® G12-150 S/F Example: MegaLine® G12-150 S/F better than Category 7A and "8" according to EN 50288 and better than Category 7A and "8" according to EN 50288 and IEC IEC 61156, excellent NEXT, low attenuation, excellent shielding 61156, excellent NEXT, very low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew characteristics (shielding of pairs and overall shielding), low skew www.leoni-infrastructure-datacom.com 15 MegaLine® Cu data cables Office 16 SPACE concept SPACE – Application Ethernet/TV Cables and connectors form a perfect symbiosis: 4 pairs, Video/audio/TV/radio 4 connecting clips: each with GHz performance. This allows the parallel, simultaneous use of different applications via Telephone one cable and one connector: PC data, voice and images. Multimedia systems do not need to cost more than conventional systems, in which an individual cable and an individual connector is usually required for each service. This allows savings of up to 50 % of the necessary cables, connectors, wall outlets and patch panels. The large security reserves mean that multimedia applications Multiple use reduces the system costs by 15 – 30 % (depending like TV or transmission protocols with high bandwidth on the services used). The reduction in the number of cables requirements such as 10 Gigabit Ethernet and 8 Gigabit and wall outlets actually required usually also allows reductions Fiberchannel can be transmitted over 100 m. Experts have in the costs for cable ducts, switching cabinets, etc. calculated that, as far as we know today, MegaLine® Category 7A data cables allow transmission rates of as much as 100 Gbit/s. But MegaLine® data cables are capable of more The supply of current (up to 350/600 mA) and voltage (up to 48 V) The use of low-loss broadband S/FTP cables with individual can be provided via PoE/PoE+ (according to IEEE 802.3a/at). or overall shielding in conjunction with multimedia cabling The current is fed in centrally via the floor distributor or switch. systems such as ELine 1200® EC7 allows so-called cable Devices such as IP telephones, Web cameras, WLAN access points, or service sharing. etc. are supplied via the telecommunications outlet. The voltage is tapped via a phantom circuit or two unassigned pairs. Application (Ethernet, TV) A 1 > 100 MbE 2 > 1 GbE A A A A A 1 >100 Mbit/s (Fast Ethernet) IEEE 802.3 u 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV The SPACE concept provides five different application levels. 2 >1,000 Mbit/s (Gigabit Ethernet) IEEE 802.3 ab 3 ≤10,000 Mbit/s (10 Gigabit Ethernet) IEEE 802.3 an 4 >10,000 Mbit/s (10 Gigabit Ethernet) IEEE 802.3 an 5 >10,000 Mbit/s (10 Gigabit Ethernet) and TV IEEE 802.3 an and Multimedia www.leoni-infrastructure-datacom.com Office Industry DataCenter SPACE concept 17 SPACE – Construction High-precision conductor and core geometries, optimally The designs have low overall diameters, thus allowing high matched lay lengths in the pairs and the use of very high- packing densities and small bending radii. The weight quality insulation and sheath materials are the characteristic reductions and the robust cable construction offer advantages features of our range of cables. for assembly and installation, even under difficult conditions. Our cables are produced on ultra-modern equipment which The five different conductor classes describe the permitted corresponds with the "state of the art" as a result of procedural tensile stress during installation and the conductor innovations. The use of physical foaming in the manufacture resistance. of high-frequency cores allows excellent, uniform electrical and geometrical characteristics to be achieved. Double skin layers ensure excellent mechanical stability while patented stranding techniques demonstrate technical leadership. C Construction (conductor dimensions, tensile strength) C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 1 AWG 27 (7x0.14 mm/0.112 mm2) 5 AWG 22 The current-handling capacity for a maximum ambient Tensile stress: max. 40/20 N (4 p/2 p) Conductor resistance: max. 170 Ω/km C 2 AWG 26/AWG 25 ➔  C21  AWG 26 (7x0.16 mm/0.14 mm2) temperature of 60 °C and the maximum installation Tensile stress: max. 60/30 N (4 p/2 p) lengths in the transmission channel can be derived from Conductor resistance: max. 145 Ω/km this on request. ➔  C22  AWG 25 (7x0.18 mm/0.175 mm2) Tensile stress: max. 70/35 N (4 p/2 p) Conductor resistance: max. 120 Ω/km C 3  AWG 24 (0.51 mm/0.205 mm2) Tensile stress: max. 90/45 N (4 p/2 p) Conductor resistance: max. 95 Ω/km C 4  AWG 23 (0.57 mm/0.258 mm2) Tensile stress: max. 110/55 N (4 p/2 p) Conductor resistance: max. 75 Ω/km C 5  AWG 22 (0.64 mm/0.325 mm2) Tensile stress: max. 130/65 N (4 p/2 p) Conductor resistance: max. 57 Ω/km www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Conductor dimensions 18 SPACE concept SPACE – EMC Coupling attenuation Electromagnetic compatibility (EMC) The main danger is increasingly a result of the alien This refers to the ability of devices, systems and plants crosstalk between adjacent data cables. Depending on their to function satisfactorily in an electromagnetic environment construction, data cables have different capabilities with regard without negative effects on other devices, systems or plants. to the prevention or reduction of interference. EMC legislation prescribes the electromagnetic compatibility of devices, systems and plants. The limits for the emission ■■ Unshielded data cables have very good symmetry of interference and the immunity to interference which characteristics but are not shielded against internal, external must be observed are regulated in EN 55022 (Class B) and or adjacent sources of interference. They are endangered to EN 50082-1/2 / EN 55024. a high degree by the environment in which they are installed. A data cable must resist electromagnetic influences coming ■■ Data cables with individual or overall shielding have very from the outside to the inside (immunity to interference) good symmetry characteristics and good or even very good and from the inside to the outside (emission of interference). shield characteristics. The EMC is very good or even excellent. The susceptibility of data cable systems to interference Interference coming from the installation environment increases in step with the transmission frequency (adjacent data cables) can be ruled out completely. and the data rates (currently 10 Gigabit Ethernet). MegaLine® data cables with a dual shielding reach values Electromagnetic compatibility of >80 dB up to 1,000 MHz, thus suppressing incoming Construction U/UTP F/UTP S/FTP Symmetry characteristics +++ ++ ++ or outgoing potential interference by a factor of >10,000. Shielding characteristics low + +++ Cables with individual and overall shielding (S/FTP) Influence of the installation environment high medium low have excellent EMC, making them an obvious choice for the fail-safe transmission of high data rates such as those offered by 10 Gigabit Ethernet. E EMC (coupling attenuation) E 1 > 40 dB 2 > 50 dB 1  Coupling attenuation >40 dB 3 > 60 dB 4 > 70 dB 5 > 80 dB Interference suppression exceeding a factor of 100 E 2  Coupling attenuation >50 dB E 3  Coupling attenuation >60 dB E 4  Coupling attenuation >70 dB E 5  Coupling attenuation >80 dB Interference suppression exceeding a factor of 300 With the MegaLine® SPACE concept, LEONI provides five different EMC levels to choose from. Interference suppression exceeding a factor of 1,000 The evaluation criterion is the coupling attenuation (interference power suppression). As the sum of the shielding attenuation and the symmetry attenuation, the coupling attenuation is the "be-all and end-all" for the assessment and comparison of the overall EMC behaviour of data cables with various different constructions. Interference suppression exceeding a factor of 3,000 Interference suppression exceeding a factor of 10,000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 19 Type codes MegaLine® F10-130 S/F H Cabling class Class "G" Class F Class E Class D "G" F E D Bandwidth acc. to standard (factor 100) 1,200 MHz 1,000 MHz 600 MHz 500 MHz 250 MHz 100 MHz 12 10 6 5 2 1 MegaLine® bandwidth (factor 10) 1,500 MHz 1,300 MHz 1,150 MHz 900 MHz 800 MHz 700 MHz 450 MHz 300 MHz 200 MHz 150 130 115 90 80 70 45 30 20 TP (twisted pair) design Overall shielding (copper braiding)/individual shield (foil) Overall shielding (foil)/individual shielding (foil) Unshielded/individual shielding (foil) Overall shielding (copper braiding & foil)/unshielded Overall shielding (foil)/unshielded Unshielded/unshielded S/F F/F U/F SF/U F/U U/U Sheath/armouring Halogen-free, flame-retardant PVC PE PUR Sheath Reinforced sheath for industrial applications Oil-resistant Steel wire braiding H Y 2Y 11Y (L)2Y V Ö Q The type codes for the MegaLine® copper data cables are compatible in structure with the SPACE concept. This makes it easier to assign cables to the old and new cabling classes and the corresponding categories. www.leoni-infrastructure-datacom.com The type codes also include: ■■ Information about the bandwidth in comparison to the standard ■■ Information about the design according to the international standard ■■ Information about the material used for the sheath Cu data cable: MegaLine® F10-130 S/F H F Acc. to new cabling class FA (1,000 MHz) 10 Bandwidth acc. to standard: 1,000 MHz 130 MegaLine® bandwidth: 1,300 MHz S/F S/FTP design H With halogen-free outer sheath MegaLine® Cu data cables MegaLine® Cu data cables 20 Cable types MegaLine® Cu data cables Cable type x x / x x x Overall shielding F S SF Foil shielding Braided shielding Braided and foil shielding Individual shielding Foil shielding U F Symmetrical element P Unshielded S/FTP (PiMF with overall shielding) F/FTP U/FTP Outer sheath Outer sheath Outer sheath Braided shielding Foil shielding Cable pair Cable pair Cable pair Foil shielding Foil shielding Foil shielding Conductor Conductor Conductor SF/UTP F/UTP U/UTP Outer sheath Outer sheath Outer sheath Foil shielding Braided and foil shielding Cable pair Cable pair Cable pairs separated by a cross element Conductor Conductor Conductor Cable type SF/UTP Cable with overall braided and foil shielding/ There are a large number of different type designations. with unshielded individual elements The standardisation defined in ISO/IEC 11801 2nd Edition determines the elements of the design in an unambiguous way. S/FTP Cable with overall braided shielding/ with individual elements with foil shielding PiMF Pair in metal foil (xx/FTP) www.leoni-infrastructure-datacom.com Office Industry DataCenter MegaLine® Cu data cables 21 www.leoni-infrastructure-datacom.com 22 MegaLine® G12-150 S/F Type KS-02YSCH 4x2xAWG 22/1 PIMF Category "8" S3 P5 A5 C5 E5 Construction Conductor Bare copper wire, AWG 22/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.6 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.74 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 ("8") acc. to EN 50288 and IEC 61156, excellent NEXT, very low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,500 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) and for home cabling systems acc. to ISO/IEC 15018 and EN 50173-4. Ideal for all applications from Classes D to FA Multimedia (TV, video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 130 N 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 2 mΩ/m Shielding attenuation up to 1,200 MHz (nominal value) 80 dB Coupling attenuation up to 1,200 MHz (nominal value) 90 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office DataCenter Industry 23 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB Cat. "8" max.* PSNEXT dB typ. Cat. "8" min.* typ. Cat. "8" min.* ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. "8" min.* typ. typ. Cat. "8" min.* typ. Cat. "8" min.* Cat. "8" min.* RL dB typ. Cat. "8" min.* 1 1.6 1.9 110 80 107 77 108 78 105 75 109 80 106 77 26.1 23 10 4.2 5.4 110 78 107 75 106 72 103 69 109 74 106 71 32.3 25 20.1 100 14.4 17.5 110 76 107 73 96 58 93 55 93 54 90 51 36.2 200 21.5 25.3 110 72 107 69 88 47 85 46 86 48 83 45 35.5 18 250 24.5 28.5 105 70 102 67 81 42 78 39 83 46 80 43 34.8 17.3 17.3 500 34 41.8 105 65.5 102 62.5 71 24 68 21 70 40 67 37 31.8 600 37.7 46.3 100 64.3 97 61.3 62 18 59 15 64 38.4 61 35.4 28.5 17.3 800 44.5 54.5 95 62.5 92 59.5 50 8 47 5 58 35.9 55 32.9 25.3 16.1 15.5 900 48.1 58.4 95 61.7 92 58.7 47 3 44 0 54 34.9 51 31.9 23.8 1000 49 62 92 61 89 58 43 –1.1 40 –4 49 34 46 31 22.2 15.1 1200 54.9 69 88 59.8 85 56.8 34 –9 31 –12 40 32.4 37 29.4 20.2 14.3 1300 57 – 81 – 78 – 24 – 21 – 35 – 32 – 18.3 – 1400 58.1 – 74 – 71 – 16 – 13 – 30 – 27 – 16.3 – 1500 62 – 73 – 70 – 11 – 8 – 25 – 22 – 12.3 – * EN 50288-4-1(2004)/IEC 61156-5(2002)/IEC 61156-7(2003) Printing on outer sheath Electrical characteristics (LF) at 20 °C DC resistance max. 57.1 Ω/km LEONI MegaLine G12-150 S/F 4P H SPACE Code 35555 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,000 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 3 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 8.6 80 48 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. ● Rape yellow RAL 1021 LKD 7KS8 0001 0000 MegaLine® Cu data cables Frequency MHz 24 MegaLine® F10-130 S/F Types KS-02YSCH 4x2xAWG 22/1 PIMF KS-02YSCH 2x(4x2xAWG 22/1 PIMF) Category 7A S3 P4 A4 C5 E5 Construction 4 p Conductor Bare copper wire, AWG 22/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.6 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.70 MJ/m (Sx), 1.4 MJ/m (Dx) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7A acc. to EN 50288 and IEC 61156, excellent NEXT, very low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,300 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to FA Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 130 N (Sx), 260 N (Dx) 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 70 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office DataCenter Industry 25 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB typ. Cat. 7A max.* PSNEXT dB Cat. 7A min.* typ. ACR dB at 100 m PSACR dB at 100 m ACRF dB at 100 m PSACRF dB at 100 m Cat. 7A min.* typ. Cat. 7A min.* typ. typ. typ. Cat. 7A min.* Cat. 7A min.* Cat. 7A min.* RL dB typ. Cat. 7A min.* 1 1.7 2.1 105 78 102 75 104 75.9 101 72.9 105 78 102 75 27.1 20 10 4.5 5.8 105 78 102 75 101 72.2 98 69.2 108 75.3 105 72.3 35.2 25 20.1 100 15.4 18.5 105 75.4 102 72.4 90 56.9 87 53.9 93 55.3 90 52.3 38.9 200 22.9 26.5 105 70.9 102 67.9 83 44.4 80 41.4 85 49.3 82 46.3 36.6 18 250 26 29.7 105 69.4 102 66.4 79 39.7 76 36.7 82 47.3 79 44.3 35.3 17.3 500 35.9 42.8 100 64.9 97 61.9 64 22.2 61 19.2 70 41.3 67 38.3 29.4 17.3 600 40.4 47.1 95 63.7 92 60.7 55 16.6 52 13.6 63 39.7 60 36.7 26.6 17.3 16.6 700 44.6 51.1 95 62.7 92 59.7 50 11.6 47 8.6 60 38.4 57 35.4 25.8 800 47.7 54.9 93 61.9 90 58.9 45 6.9 42 3.9 57 37.2 54 34.2 25 16.1 900 51.6 58.5 90 61.1 87 58.1 38 2.6 35 –0.4 53 36.2 50 33.2 23.6 15.5 1000 54.8 61.9 88 60.4 85 57.4 33 –1.5 30 –4.5 48 35.3 45 32.3 22.3 15.1 1100 56.9 – 87 – 84 – 30 – 27 – 44 – 41 – 21.4 – 1300 61.4 – 80 – 77 – 21 – 18 – 39 – 36 – 18.3 – * EN 50288-4-1 (2004)/IEC 61156-5 (2002) Configuring multiple single elements can result in attenuation values that are up to 3 % higher and frequency-selective reflections in the case of multi-types. Printing on outer sheath 4 p Electrical characteristics (LF) at 20 °C DC resistance max. 57.1 Ω/km LEONI MegaLine F10-130 S/F 4P H SPACE Code 34455 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 40 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content Colour of sheath Order no. mm kg/km kg/km 4p 8.6 80 45 ● Rape yellow RAL 1021 LKD 7KS7 0001 0000 2x4p 8.6 x 17.5 162 90 ● Rape yellow RAL 1021 LKD 7KS7 0002 0000 Package: Drum 1,000 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 26 MegaLine® F10-125 S/F Types KS-02YSCH 4x2x0,62 mm/~AWG 22/1 PIMF Category 7A S3 P4 A4 C5 E5 Construction 4 p Conductor Bare copper wire, 0.62 mm/~AWG 22/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.5 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.65 (approx. value) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Leistungsmerkmale Better than Category 7A acc. to EN 50288 and IEC 61156, excellent NEXT, very low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,300 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to FA Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 70 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office DataCenter Industry 27 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB typ. Cat. 7A max.* PSNEXT dB Cat. 7A min.* typ. ACR dB at 100 m PSACR dB at 100 m ACRF dB at 100 m PSACRF dB at 100 m Cat. 7A min.* typ. Cat. 7A min.* typ. typ. typ. Cat. 7A min.* Cat. 7A min.* Cat. 7A min.* RL dB typ. Cat. 7A min.* 1 1.8 2.1 105 78 102 75 104 75.9 101 72.9 105 78 102 75 27.1 20 10 4.7 5.8 105 78 102 75 101 72.2 98 69.2 108 75.3 105 72.3 35.2 25 20.1 100 15.9 18.5 105 75.4 102 72.4 89 56.9 86 53.9 93 55.3 90 52.3 38.9 200 23.5 26.5 105 70.9 102 67.9 81 44.4 78 41.4 85 49.3 82 46.3 36.6 18 250 26.6 29.7 105 69.4 102 66.4 79 39.7 76 36.7 82 47.3 79 44.3 35.3 17.3 500 37 42.8 100 64.9 97 61.9 63 22.2 60 19.2 70 41.3 67 38.3 29.4 17.3 600 41.8 47.1 95 63.7 92 60.7 53 16.6 50 13.6 63 39.7 60 36.7 26.6 17.3 16.6 700 45.2 51.1 95 62.7 92 59.7 50 11.6 47 8.6 60 38.4 57 35.4 25.8 800 48 54.9 93 61.9 90 58.9 45 6.9 42 3.9 57 37.2 54 34.2 25 16.1 900 52.3 58.5 90 61.1 87 58.1 38 2.6 35 –0.4 53 36.2 50 33.2 23.6 15.5 1000 55.2 61.9 88 60.4 85 57.4 33 –1.5 30 –4.5 48 35.3 45 32.3 22.3 15.1 1100 57.6 – 87 – 84 – 29 – 26 – 44 – 41 – 21.4 – 1300 64.9 – 80 – 77 – 15 – 13 – 39 – 36 – 18.3 – * EN 50288-9 (draft)/EN 50288-4-1 (2004) / IEC 61156-5 (2009) Printing on outer sheath 4 p Electrical characteristics at 20 °C DC resistance max. 65 Ω/km LEONI MegaLine F10-125 S/F 4P H SPACE Code 34455 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 8.1 68 38 4P Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. ● Rape yellow RAL 1021 LKD 7KS7 0253 0000 MegaLine® Cu data cables Frequency MHz 28 MegaLine® F10-115 S/F Types KS-02YSCH 4x2xAWG 23/1 PIMF KS-02YSCH 2/4/6x(4x2xAWG 23/1 PIMF) Category 7A S3 P4 A4 C4 E5 Construction 4 p Conductor Bare copper wire, AWG 23/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.4 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.60 MJ/m (Sx), 1.2 MJ/m (Dx), 4.24 MJ/m (4 p), 6.29 MJ/m (6 p) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7A acc. to EN 50288 and IEC 61156 excellent NEXT, very low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,150 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to FA Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N (Sx), 220 N (Dx), 440 N (4 p), 650 N (6 p) 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 70 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office DataCenter Industry 29 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB PSNEXT dB ACR dB at 100 m PSACR dB at 100 m ACRF dB at 100 m PSACRF dB at 100 m Cat. 7A min.* typ. typ. typ. Cat. 7A max.* typ. Cat. 7A min.* typ. Cat. 7A min.* typ. Cat. 7A min.* Cat. 7A min.* RL dB Cat. 7A min.* typ. Cat. 7A min.* 1 1.9 2.1 105 78 102 75 104 75.9 101 72.9 98 78 95 75 26.6 20 10 4.8 5.8 105 78 102 75 101 72.2 98 69.2 103 75.3 100 72.3 35.3 25 20.1 100 16.3 18.5 105 75.4 102 72.4 89 56.9 86 53.9 89 55.3 86 52.3 39.6 200 24.3 26.5 105 70.9 102 67.9 81 44.4 78 41.4 82 49.3 79 46.3 36 18 250 27.5 29.7 105 69.4 102 66.4 78 39.7 75 36.7 79 47.3 76 44.3 34 17.3 500 37.9 42.8 100 64.9 97 61.9 62 22.2 59 19.2 67 41.3 64 38.3 29 17.3 600 42.4 47.1 95 63.7 92 60.7 53 16.6 50 13.6 60 39.7 57 36.7 25.4 17.3 16.6 700 47.2 51.1 95 62.7 92 59.7 48 11.6 45 8.6 57 38.4 54 35.4 24.6 800 50.3 54.9 93 61.9 90 58.9 43 6.9 40 3.9 53 37.2 50 34.2 23.5 16.1 900 54.6 58.5 90 61.1 87 58.1 35 2.6 32 –0.4 49 36.2 46 33.2 22.6 15.5 1000 58 61.9 88 60.4 85 57.4 30 –1.5 27 –4.5 44 35.3 41 32.3 21.5 15.1 1150 61.9 – 86 – 83 – 25 – 22 – 39 – 36 – 20.6 – 1200 64 – 85 – 82 – 21 – 18 – 35 – 32 – 19 – * EN 50288-4-1 (2004)/IEC 61156-5 (2002) Printing on outer sheath 4 p Electrical characteristics (LF) at 20 °C DC resistance max. 75 Ω/km LEONI MegaLine F10-115 S/F 4P H SPACE Code 34445 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content Colour of sheath Order no. mm kg/km kg/km 4p 7.5 67 37 ● Rape yellow RAL 1021 LKD 7KS7 0008 0000 2x4p 7.5 x 15.2 136 74 ● Rape yellow RAL 1021 LKD 7KS7 0009 0000 4x4p 19.9 365 148 ● Rape yellow RAL 1021 LKD 7KS7 0161 0000 6x4p 23.6 514 222 ● Rape yellow RAL 1021 LKD 7KS7 0186 0000 Package: Drum 1,000 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 30 MegaLine® F6-90 S/F Types KS-02YSCH 4x2xAWG 23/1 PIMF KS-02YSCH 2/4/6/8x(4x2xAWG 23/1 PIMF) Category 7 S3 P3 A4 C4 E5 Construction 4 p Conductor Bare copper wire, AWG 23/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.4 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.60 MJ/m (Sx), 1.2 MJ/m (Dx), 4.3 MJ/m (4 p), 6.9 MJ/m (6 p), 9.6 MJ/m (8 p) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,000 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to F Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N (Sx), 220 N (Dx), 400 N (4 p), 600 N (6 p), 850 N (8 p) 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 70 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office DataCenter Industry 31 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB Cat. 7 max.* typ. PSNEXT dB Cat. 7 min.* typ. ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m Cat. 7 min.* typ. Cat. 7 min.* typ. typ. Cat. 7 min.* typ. Cat. 7 min.* typ. Cat. 7 min.* 23 Cat. 7 min.* RL dB 1 1.9 2 102 80 99 77 101 78 98 75 109 80 106 77 25.4 10 4.8 5.7 102 80 99 77 98 74 95 71 108 74 105 71 31.1 25 100 16.4 18.5 102 72 99 69 86 54 83 51 93 54 90 51 33.2 20.1 200 24.5 26.8 102 68 99 65 78 41 75 38 85 48 82 45 33.2 18 250 27.8 30.2 102 66 99 63 75 36 72 33 82 46 79 43 33.4 17.3 450 36.1 41.6 97 63 94 60 61 21 58 18 72 41 69 38 31.4 17.3 500 38.2 44.1 97 62 94 59 59 18 56 15 68 40 65 37 30.5 17.3 600 42.9 48.9 92 61 89 58 49 12 46 9 62 38 59 35 27.6 17.3 700 47.7 – 92 – 89 – 44 – 41 – 59 – 56 – 26.2 – 800 50.8 – 90 – 87 – 39 – 36 – 56 – 53 – 23.9 – 900 55.1 – 85 – 82 – 30 – 27 – 52 – 49 – 21.7 – 1000 58.0 – 80 – 77 – 22 – 19 – 42 – 39 – 18.0 – * EN 50288-4-1(2004)/IEC 61156-5(2002) Stranding together multiple single elements can result in attenuation values that are up to 5 % higher and frequency-selective reflections in the case of multi-types. Printing on outer sheath Electrical characteristics (LF) at 20 °C DC resistance max. 75 Ω/km LEONI MegaLine F6-90 S/F 4P H SPACE Code 33445 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content Colour of sheath Order no. mm kg/km kg/km 4p 7.4 57 35 ● Rape yellow RAL 1021 LKD 7KS7 0010 0000 LKD 7KS7 0011 0000 2x4p 7.5 x 15.2 117 70 ● Rape yellow RAL 1021 4x4p 18.9 338 148 ● Rape yellow RAL 1021 LKD 7KS7 0114 0000 6x4p 24.9 507 222 ● Rape yellow RAL 1021 LKD 7KS7 0198 0000 8x4p 27.9 674 296 ● Rape yellow RAL 1021 LKD 7KS7 0194 0000 Package: Drum 1,000 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 32 MegaLine® E5-70 S/F Types KS-02YSCH 4x2xAWG 23/1 PIMF KS-02YSCH 2x(4x2xAWG 23/1 PIMF) Category 6A S3 P2 A3 C4 E4 Construction 4 p Conductor Bare copper wire, AWG 23/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.4 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (Fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.60 MJ/m (Sx), 1.2 NJ/m (Dx) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 6A acc. to EN 50288 and IEC 61156 very good NEXT, very good shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 700 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to EA up to 10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N (Sx), 220 N (Dx) 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 60 dB Coupling attenuation up to 1,000 MHz (nominal value) 80 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Industry DataCenter 33 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB typ. Cat. 6A max.* PSNEXT dB Cat. 6A min.* typ. Cat. 6A min.* ACR dB at 100 m PSACR dB at 100 m ACRF dB at 100 m PSACRF dB at 100 m typ. Cat. 6A min.* typ. Cat. 6A min.* typ. Cat. 6A min.* typ. RL dB Cat. 6A min.* typ. Cat. 6A min.* 1 1.9 2.1 95 75.3 92 72.3 93 73.2 90 70.2 91 68 88 65 26 20 10 5.2 5.9 90 60.3 87 57.3 85 54.4 82 51.4 96 48 93 45 35.9 25 20.1 100 17.7 19.1 75 45.3 72 42.3 57 26.2 54 23.2 90 28 87 25 37.2 200 26.4 27.6 68 40.8 65 37.8 42 13.2 39 10.2 78 22 75 19 33.1 18 250 29.9 31.1 66 39.3 63 36.3 36 8.3 33 5.3 75 20 72 17 30.5 17.3 300 31.9 34.3 65 38.1 62 35.1 33 3.9 30 0.9 72 18.5 69 15.5 29.9 17.3 450 38.9 42.7 63 35.5 60 32.5 24 –7.2 21 –10.2 69 14.9 66 11.9 28.9 17.3 500 41.2 45.3 61 34.8 58 31.8 20 –10.4 17 –13.4 66 14 63 11 28.3 17.3 600 46.2 – 57 – 54 – 11 – 8 – 60 – 57 – 27.2 – 700 51.4 – 54 – 51 – 3 – 0 – 56 – 53 – 26.2 – * EN 50288-10-1 (draft)/EN 50288-5-1 (2004)/IEC 61156-5 (2009) Printing on outer sheath 4 p Electrical characteristics (LF) at 20 °C DC resistance max. 82 Ω/km LEONI MegaLine E5-70 S/F 4P H SPACE Code 32344 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 7 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content Colour of sheath Order no. mm kg/km kg/km 4p 7.4 55 30 ● Rape yellow RAL 1021 LKD 7KS6 0024 0000 2x4p 7.4 x 15.0 112 60 ● Rape yellow RAL 1021 LKD 7KS6 0025 0000 Package: Drum 1,000 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 34 MegaLine® E5-70 F/F Types KS-02YS(ST)H 4x2xAWG 23/1 PIMF KS-02YS(ST)H 2x(4x2xAWG 23/1 PIMF) Category 6A S3 P2 A3 C4 E3 Construction 4 p Conductor Bare copper wire, AWG 23/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.4 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Aluminium-bonded polyester foil, metal side inside and underlayed tinned copper drain wire Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.60 MJ/m (Sx), 1.2 MJ/m (Dx) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 6A acc. to EN 50288 and IEC 61156 very good NEXT, good shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 700 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to EA up to 10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N (Sx), 220 N (Dx) 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 50 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 60 dB Coupling attenuation up to 1,000 MHz (nominal value) 70 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Industry DataCenter 35 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB typ. Cat. 6A max.* PSNEXT dB Cat. 6A min.* typ. Cat. 6A min.* ACR dB at 100 m PSACR dB at 100 m ACRF dB at 100 m PSACRF dB at 100 m typ. Cat. 6A min.* typ. Cat. 6A min.* typ. Cat. 6A min.* typ. Cat. 6A min.* RL dB typ. Cat. 6A min.* 1 1.9 2.1 95 75.3 92 72.3 93 73.2 90 70.2 91 68 88 65 25.1 – 10 5.2 5.9 90 60.3 87 57.3 85 54.4 82 51.4 96 48 93 45 35.2 25 20.1 100 17.7 19.1 75 45.3 72 42.3 57 26.2 54 23.2 90 28 87 25 37.2 200 26.4 27.6 68 40.8 65 37.8 42 13.2 39 10.2 78 22 75 19 31.1 18 250 29.9 31.1 66 39.3 63 36.3 36 8.3 33 5.3 75 20 72 17 29.5 17.3 300 31.9 34.3 65 38.1 62 35.1 33 3.9 30 0.9 72 18.5 69 15.5 28.3 17.3 450 38.9 42.7 63 35.5 60 32.5 24 –7.2 21 –10.2 69 14.9 66 11.9 26.7 17.3 500 41.2 45.3 61 34.8 58 31.8 20 –10.4 17 –13.4 66 14 63 11 26.3 17.3 600 46.2 – 57 – 54 – 11 – 8 – 60 – 57 – 25.8 – 700 51.4 – 54 – 51 – 3 – 0 – 56 – 53 – – – * EN 50288-10-1 (draft)/EN 50288-5-1(2004)/IEC 61156-5(2009) Printing on outer sheath 4 p Electrical characteristics (LF) at 20 °C DC resistance max. 82 Ω/km LEONI MegaLine E5-70 F/F 4P H SPACE Code 32343 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 417 ns/100 m Skew at 100 MHz approx. 7 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km Colour of sheath Order no. 4p 7.5 58 23,5 ● Rape yellow RAL 1021 LKD 7KS6 0022 0000 2x4p 7.5 x 15.2 120 47 ● Rape yellow RAL 1021 LKD 7KS6 0023 0000 Package: Drum 1,000 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 36 MegaLine® E5-60 U/F Types KS-02YSH 4x2xAWG 23/1 PIMF KS-02YSH 2x(4x2xAWG 23/1 PIMF) Category 6A S3 P2 A3 C4 E3 Construction 4 p Conductor Bare copper wire, AWG 23/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.4 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Plastic foil (optional) and underlayed tinned copper drain wire AWG 24/1 Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.60 MJ/m (Sx), 1.2 MJ/m (Dx) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 6A acc. to EN 50288 and IEC 61156 very good NEXT, good shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 600 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to EA up to 10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N (Sx), 220 N (Dx) 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 50 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 55 dB Coupling attenuation up to 1,000 MHz (nominal value) 65 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Industry DataCenter 37 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB typ. Cat. 6A max.* PSNEXT dB Cat. 6A min.* typ. Cat. 6A min.* ACR dB at 100 m PSACR dB at 100 m ACRF dB at 100 m PSACRF dB at 100 m typ. Cat. 6A min.* typ. Cat. 6A min.* typ. Cat. 6A min.* typ. Cat. 6A min.* RL dB typ. Cat. 6A min.* 1 1.9 2.1 95 75.3 92 72.3 93 73.2 90 70.2 91 68 88 65 25.1 – 10 5.2 5.9 90 60.3 87 57.3 85 54.4 82 51.4 96 48 93 45 35.2 25 20.1 100 17.7 19.1 75 45.3 72 42.3 57 26.2 54 23.2 90 28 87 25 37.2 200 26.4 27.6 68 40.8 65 37.8 42 13.2 39 10.2 78 22 75 19 31.1 18 250 29.9 31.1 66 39.3 63 36.3 36 8.3 33 5.3 75 20 72 17 29.5 17.3 300 31.9 34.3 65 38.1 62 35.1 33 3.9 30 0.9 72 18.5 69 15.5 28.3 17.3 450 38.9 42.7 63 35.5 60 32.5 24 –7.2 21 –10.2 69 14.9 66 11.9 26.7 17.3 500 41.2 45.3 61 34.8 58 31.8 20 –10.4 17 –13.4 66 14 63 11 26.3 17.3 600 46.2 – 57 – 54 – 11 – 8 – 60 – 57 – 25.8 – * EN 50288-10-1 (draft)/EN 50288-5-1(2004)/IEC 61156-5(2009) Printing on outer sheath 4 p Electrical characteristics (LF) at 20 °C DC resistance max. 82 Ω/km LEONI MegaLine E5-60 U/F 4P H SPACE Code 32343 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 7 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content Colour of sheath Order no. mm kg/km kg/km 4p 7.2 53 25 ● Rape yellow RAL 1021 LKD 7KS6 0035 0000 2x4p 7.4 X 15.0 112 50 ● Rape yellow RAL 1021 LKD 7KS6 0036 0000 Package: Drum 1,000 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 38 MegaLine® E2-45 U/F Types KS-02YSH 4x2xAWG 23/1 PIMF KS-02YSH 2x(4x2xAWG 23/1 PIMF) Category 6 S2 P1 A2 C4 E2 Construction 4 p Conductor Bare copper wire, AWG 23/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.4 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Tape Plastic foil (optional) and underlayed tinned copper drain wire AWG 24/1 Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-1-2 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.60 MJ/m (Sx), 1.2 NJ/m (Dx) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 6 acc. to EN 50288 and IEC 61156 very good NEXT, low skew, bandwidth 450 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to E up to 1 GbE acc. to IEEE 802.3 ab, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N (Sx), 220 N (Dx) 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 80 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 50 dB Coupling attenuation up to 1,000 MHz (nominal value) 60 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Industry DataCenter 39 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB Cat. 6 max.* PSNEXT dB typ. Cat. 6 min.* ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. 6 min.* typ. Cat. 6 min.* typ. Cat. 6 min.* typ. Cat. 6 min.* typ. Cat. 6 min.* RL dB typ. Cat. 6 min.* 1 1.9 2.1 95 66 92 64 93 64 90 62 88 66 85 64 25.4 – 4 3.2 3.8 95 65 92 63 92 61 89 59 89 58 86 55 28.6 23 10 5.2 6 90 59 87 57 85 53 82 51 92 50 89 47 33.5 25 16 7 7.6 90 56 87 54 83 49 80 47 98 46 95 43 35.6 25 31.25 9.9 10.7 85 52 82 50 75 41 72 39 98 40 95 37 37 23.6 62.5 13.5 15.5 80 47 77 45 66 32 63 30 95 34 92 31 35.9 21.5 100 17.9 19.9 75 44 72 42 57 24 54 22 88 30 85 27 34.3 20.1 155 22.5 25.3 72 41 69 39 49 16 46 14 81 26 78 23 32.2 18.8 200 26.9 29.1 68 40 65 38 41 11 38 9 75 24 72 21 31.3 18 250 30.4 33 66 38 63 36 36 5 33 3 72 22 69 19 29.2 17.3 300 33.1 – 65 – 62 – 32 – 29 – 69 – 66 – 28 – 450 39.3 – 63 – 60 – 24 – 21 – 64 – 61 – 27 – * EN 50288-5-1(2004)/IEC 61156-5(2002) Printing on outer sheath 4 p Electrical characteristics (LF) at 20 °C DC resistance max. 82 Ω/km LEONI MegaLine E2-45 U/F 4P H SPACE Code 21242 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 7 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content Colour of sheath Order no. mm kg/km kg/km 4p 7.4 55 23,5 ● Rape yellow RAL 1021 LKD 7KS6 0005 0000 2x4p 7.4 x 15.0 114 47 ● Rape yellow RAL 1021 LKD 7KS6 0006 0000 Package: Drum 1,000 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 40 MegaLine® E2-30 F/U Type KS-2Y(ST)H 4x2xAWG 23/1 Category 6 S2 P1 A2 C4 E2 Construction Conductor Bare copper wire, AWG 23/1 Insulation Twisting element PE Pair Twisting 4 pairs separated by a cross element Overall shielding Aluminium-bonded polyester foil, metal side inside and underlayed tinned copper drain wire Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-1-2 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.7 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 6 acc. to EN 50288 and IEC 61156 bandwidth 300 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to E up to 1 GbE acc. to IEEE 802.3 ab, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 40 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 50 dB Coupling attenuation up to 1,000 MHz (nominal value) 70 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Industry DataCenter 41 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB Cat. 6 max.* PSNEXT dB typ. Cat. 6 min.* typ. Cat. 6 min.* ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. 6 min.* typ. Cat. 6 min.* typ. Cat. 6 min.* typ. Cat. 6 min.* RL dB typ. Cat. 6 min.* 1 1.8 2.1 93 66 90 64 91 64 88 62 103 66 100 64 24.6 – 4 2.9 3.8 87 65 84 63 84 61 81 59 95 58 92 55 30.8 23 10 5.1 6 80 59 77 57 75 53 72 51 85 50 82 47 36.7 25 16 7 7.6 75 56 72 54 68 49 65 47 78 46 75 43 38.4 25 32.25 10 10.9 71 52 68 50 61 41 58 39 71 40 68 37 37.9 23.6 62.5 13.5 15.5 67 47 64 45 53 32 50 30 65 34 62 31 35.5 21.5 100 17.8 19.9 63 44 60 42 45 24 42 22 60 30 57 27 31.9 20.1 155 22.4 25.3 59 41 56 39 37 16 34 14 53 26 50 23 28.7 18.8 200 26.8 29.1 57 40 54 38 30 11 27 9 48 24 45 21 25.9 18 250 30.4 33 56 38 53 36 26 5 23 3 44 22 41 19 25.5 17.3 300 32.8 – 53 – 50 – 20 – 17 – 38 – 35 – 23.6 – * EN 50288-5-1(2004)/IEC 61156-5(2002) Electrical characteristics (LF) at 20 °C Printing on outer sheath DC resistance max. 75 Ω/km LEONI MegaLine E2-30 F/U 4P H SPACE Code 21242 Insulation resistance min. 5 GΩ x km "production lot code" "meter marking" Mutual capacitance approx. 41 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.66 whbu/bu, whor/or, whgn/gn, whbn/bn Propagation delay approx. 510 ns/100 m Skew at 100 MHz approx. 25 ns/100 m Certificates and approvals Characteristic impedance at 100 MHz 100 ± 5 Ω Link performance: LEONI MegaLine® systems Testing voltage Ueff Operating voltage 1,000 V max. 125 V and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Conforms to LVD (73/23/EEC): Thermal characteristics For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 7.2 55 21 4p Package: Drum 1,000 m/500 m, box 305 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. ● Rape yellow RAL 1021 LKD 7KS6 0004 0000 MegaLine® Cu data cables Frequency MHz 42 MegaLine® E2-30 U/U Type KS-2YH 4x2xAWG 23/1 Category 6 S2 P1 A2 C4 E1 Construction Conductor Bare copper wire, AWG 23/1 Insulation Twisting element PE Pair Twisting 4 pairs separated by a cross element Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-1-2 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.65 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 6 acc. to EN 50288 and IEC 61156 bandwidth 300 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Suitable for applications from Classes D to E up to 1 GbE acc. to IEEE 802.3 ab, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Coupling attenuation up to 1,000 MHz (nominal value) 45 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Industry DataCenter 43 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB PSNEXT dB Cat. 6 max.* typ. Cat. 6 min.* typ. Cat. 6 min.* ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. 6 min.* typ. Cat. 6 min.* typ. Cat. 6 min.* typ. Cat. 6 min.* RL dB typ. Cat. 6 min.* 1 1.8 2.1 94 66 91 64 92 64 89 62 102 66 99 64 25.4 – 4 2.7 3.8 88 65 85 63 85 61 82 59 96 58 93 55 30.3 23 25 10 4.7 6 81 59 78 57 76 53 73 51 85 50 82 47 33.9 16 6.6 7.6 76 56 73 54 70 49 67 47 78 46 75 43 33.6 25 32.25 9.5 10.9 72 52 69 50 62 41 59 39 70 40 67 37 33.7 23.6 62.5 13 15.5 68 47 65 45 55 32 52 30 63 34 60 31 34.4 21.5 100 17.4 19.9 64 44 61 42 46 24 43 22 57 30 54 27 33.5 20.1 155 22 25.3 60 41 57 39 38 16 35 14 50 26 47 23 32.2 18.8 200 26.6 29.1 58 40 55 38 31 11 28 9 45 24 42 21 30.5 18 250 30.4 33 57 38 54 36 27 5 24 3 40 22 37 19 29 17.3 300 33.1 – 54 – 51 – 20 – 17 – 37 – 34 – 27 – * EN 50288-6-1(2004)/IEC 61156-5(2002) Electrical characteristics (LF) at 20 °C Printing on outer sheath DC resistance max. 78 Ω/km LEONI MegaLine E2-30 U/U 4P H SPACE Code 21241 Insulation resistance min. 5 GΩ x km "production lot code" "meter marking" Mutual capacitance approx. 50 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.67 whbu/bu, whor/or, whgn/gn, whbn/bn Propagation delay approx. 528 ns/100 m Skew at 100 MHz approx. 30 ns/100 m Certificates and approvals Characteristic impedance at 100 MHz 100 ± 5 Ω Link performance: LEONI MegaLine® systems Testing voltage Ueff 1,000 V Operating voltage max. 125 V and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Conforms to LVD (73/23/EEC): Thermal characteristics For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 6.4 45 21 4p Package: Drum 1,000 m, box 305 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. ● Rape yellow RAL 1021 LKD 7KS6 0002 0000 MegaLine® Cu data cables Frequency MHz 44 MegaLine® D1-20 SF/U Types KS-02YS(ST+C)H 4x2xAWG 24/1 KS-02YS(ST+C)H 2x(4x2xAWG 24/1) Category 5 S2 P0 A1 C3 E3 Construction 4 p Conductor Bare copper wire, AWG 24/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.1 mm Pair Twisting 4 pairs Overall shielding Aluminium-bonded polyester foil and tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-1-2 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.4 MJ/m (Sx), 0.81 MJ/m (Dx) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 5 acc. to EN 50288 and IEC 61156 excellent shielding characteristics, bandwidth 200 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Class D up to 1 GbE acc. to IEEE 802.3 ab, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 85 N (Sx), 170 N (Dx) 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 10 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 55 dB Coupling attenuation up to 1,000 MHz (nominal value) 70 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Industry DataCenter 45 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m NEXT dB typ. PSNEXT dB typ. Cat. 5 max.* Cat. 5 min.* 1 2 2.1 75 4 3.1 4 69 10 5.1 6.3 62 50 16 7 8 58 47 31.25 9.7 11.4 53 62.5 13.2 16.5 100 17.6 21.3 155 22.3 200 26.5 ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. 5 min.* typ. Cat. 5 min.* typ. Cat. 5 min.* typ. Cat. 5 min.* RL dB typ. Cat. 5 min.* typ. Cat. 5 min.* 65 72 62 73 63 70 60 89 64 86 61 24.8 – 56 66 53 66 52 63 49 84 52 81 49 28.6 23 59 47 57 44 54 41 76 44 73 41 33.3 25 55 44 51 39 48 36 70 40 67 37 34.3 25 43 50 40 44 31 41 28 63 34 60 31 33.9 23.6 49 38 46 35 36 22 33 19 58 28 55 25 31.3 21.5 45 35 42 32 28 14 25 11 52 24 49 21 27.7 20.1 – 42 – 39 – 20 – 17 – 49 – 46 – 24.7 – – 40 – 37 – 14 – 11 – 45 – 42 – 22.4 – * EN 50288-2-1(2004)/IEC 61156-5(2002) Electrical characteristics (LF) at 20 °C Printing on outer sheath DC resistance max. 95 Ω/km LEONI MegaLine D1-20 SF/U 4P H SPACE Code 20133 Insulation resistance min. 5 GΩ x km "production lot code" "meter marking" Mutual capacitance approx. 45 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.75 whbu/bu, whor/or, whgn/gn, whbn/bn Propagation delay approx. 440 ns/100 m Skew at 100 MHz approx. 15 ns/100 m Certificates and approvals Characteristic impedance at 100 MHz 100 ± 5 Ω Link performance: LEONI MegaLine® systems Testing voltage Ueff 1,000 V Operating voltage max. 125 V and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Conforms to LVD (73/23/EEC): Thermal characteristics For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content Colour of sheath Order no. mm kg/km kg/km 4p 6.0 42 26 ● Rape yellow RAL 1021 LKD 7KS5 0005 0000 2x4p 6.0 x 12.5 86 52 ● Rape yellow RAL 1021 LKD 7KS5 0006 0000 Package: Drum 1,000 m, box 305 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 46 MegaLine® F10-120 S/F flex Types KS-02YSCH 4x2xAWG 26/7 PIMF KS-(02YSCH) 8x(4x2xAWG 26/7 PIMF) Category 7 S2 P4 A5 C2 E5 Construction 4 p Conductor Bare stranded copper wire, AWG 26/7 Insulation Twisting element Cellular-PE, core-diameter: max. 1.05 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-1-2 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.38 MJ/m (Sx), 6.92 (8 p) S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,200 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Consolidation point cable, connection cable and patch cord for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24764 and EN 50173-5. Ideal for all applications from Classes D to FA Multimedia (TV, video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during operation Tensile strength (max.) 5 x overall diameter (min.) 60 N (Sx), 400 N (8 p) C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 60 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office DataCenter Industry 47 Electrical characteristics (HF) at 20 °C Attenuation dB/10 m NEXT dB PSNEXT dB typ. Cat. 7 max.* typ. Cat. 7 min.* ACR dB at 10 m typ. Cat. 7 min.* typ. Cat. 7 min.* PSACR dB at 10 m ELFEXT dB at 10 m PSELFEXT dB at 10 m typ. Cat. 7 min.* typ. Cat. 7 min.* typ. Cat. 7 min.* RL dB typ. Cat. 7 min.* 23 1 0.25 0.29 100 80 97 77 100 80 97 77 100 80 97 80 24 10 0.76 0.85 99 80 96 77 99 79 96 77 95 74 92 71 33.9 25 100 2.49 2.78 95 72 92 69 93 70 90 69 69 54 66 51 38.3 20.1 200 3.69 4.01 92 68 89 65 88 64 85 65 65 48 62 45 35.3 18 250 4.18 4.53 90 66 87 63 86 62 83 63 62 46 59 43 32.9 17.3 500 5.6 6.62 83 62 80 59 78 55 75 59 54 40 51 37 29.7 17.3 600 6.74 7.33 81 61 78 58 74 53 71 58 50 38 47 35 30.6 17.3 700 7.32 – 80 – 77 – 72 – 69 – 50 – 47 – 31 – 800 7.89 – 77 – 74 – 69 – 66 – 50 – 47 – 26.7 – 900 8.5 – 75 – 72 – 67 – 64 – 34 – 31 – 28.6 – 1000 9.11 – 74 – 71 – 65 – 62 – 32 – 29 – 27.5 – 1100 9.5 – 72 – 69 – 63 – 60 – 28 – 25 – 26.9 – 1200 9.9 – 70 – 67 – 61 – 58 – 24 – 21 – 26.3 – * EN 50288-4-2 (2004)/IEC 61156-6 (2002) Stranding together multiple single elements can result in attenuation values that are up to 3 % higher and frequency-selective reflections in the case of multi-types. Printing on outer sheath 4 p Electrical characteristics (LF) at 20 °C DC resistance max. 145 Ω/km LEONI MegaLine F10-120 S/F flex 4P H SPACE Code 24525 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 44 pF/m Signal velocity (c) approx. 0.78 Colour code Propagation delay approx. 440 ns/100 m wh/bu, wh/or, wh/gn, wh/bn Skew at 100 MHz approx. 2.5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Thermal characteristics Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Conforms to LVD (73/23/EEC): Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 4p 5.8 41 8x4p 24 500 Dimensions Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. 23.5 ● Light grey RAL 7035 LKD 7KS7 0003 0000 188 ● Light grey RAL 7035 LKD 7KS7 0142 0000 MegaLine® Cu data cables Frequency MHz 48 MegaLine® F6-90 S/F flex Type KS-02YSCH 4x2xAWG 27/7 PIMF Category 7 S2 P3 A4 C1 E5 Construction Conductor Bare stranded copper wire, AWG 27/7 Insulation Twisting element Cellular-PE, core-diameter: max. 1.0 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-1-2 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.33 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 900 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Connection cable and patch cord for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Classes D to F Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during operation Tensile strength (max.) 5 x overall diameter (min.) 40 N C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 60 dB Coupling attenuation up to 1,000 MHz (nominal value) 80 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office DataCenter Industry 49 Electrical characteristics (HF) at 20 °C Attenuation dB/10 m typ. Cat. 7 max.* NEXT dB typ. PSNEXT dB Cat. 7 min.* typ. Cat. 7 min.* ACR dB at 10 m PSACR dB at 10 m ELFEXT dB at 10 m typ. Cat. 7 min.* typ. Cat. 7 min.* PSELFEXT dB at 10 m typ. Cat. 7 min.* typ. Cat. 7 min.* RL dB typ. Cat. 7 min.* 1 0.26 0.29 95 80 92 77 95 80 92 77 92 80 89 80 21.8 – 10 0.83 0.85 94 80 91 77 94 79 91 77 84 74 81 71 29.7 25 20.1 100 2.74 2.78 90 72 87 69 88 70 85 69 70 54 67 51 35 200 3.9 4.01 87 68 84 65 83 64 80 65 60 48 57 45 33 18 250 4.39 4.53 85 66 82 63 81 62 78 63 56 46 53 43 31.6 17.3 500 6.21 6.62 78 62 75 59 72 55 69 59 52 40 49 37 28.8 17.3 600 6.91 7.33 76 61 73 58 69 53 66 58 48 38 45 35 27.1 17.3 – 700 7.48 – 75 – 72 – 67 – 64 – 34 – 31 – 26.4 800 8.06 – 72 – 69 – 64 – 61 – 34 – 31 – 24.7 – 900 8.62 – 70 – 67 – 62 – 59 – 11 – 8 – 24.4 – * EN 50288-4-2 (2004)/IEC 61156-6 (2002) Printing on outer sheath Electrical characteristics (LF) at 20 °C DC resistance max. 170 Ω/km LEONI MegaLine F6-90 S/F flex 4P H SPACE Code 23415 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 44 pF/m Signal velocity (c) approx. 0.78 Colour code Propagation delay approx. 430 ns/100 m wh/bu, wh/or, wh/gn, wh/bn Skew at 100 MHz approx. 2.5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Thermal characteristics Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Conforms to LVD (73/23/EEC): Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content Colour of sheath Order no. mm kg/km kg/km 4p 5.7 34 17 ● Light grey RAL 7035 LKD 7KS7 0014 0000 4p 5.7 34 17 ● Rape yellow RAL 1021 LKD 7KS7 0015 0000 4p 5.7 34 17 ● Turquoise green RAL 6016 LKD 7KS7 0016 0000 4p 5.7 34 17 ● Sky blue RAL 5015 LKD 7KS7 0017 0000 4p 5.7 34 17 ● Flame red RAL 3000 LKD 7KS7 0018 0000 Package: Drum 1,000 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 50 MegaLine® D1-20 SF/U flex Type KS-02YS(ST+C)Y 4x2xAWG 26/7 Category 5 S2 P0 A1 C2 E3 Construction Conductor Bare stranded copper wire, AWG 26/7 Insulation Twisting element Twisting Cellular-PE, core-diameter: max. 1.0 mm Pair 4 pairs Overall shielding Aluminium-bonded polyester foil and tinned copper braiding Outer sheath PVC Security (fire behaviour) Fire behaviour Flame retardancy Calorific value (approx.) acc. to IEC 60332-1-2 0.35 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 5 acc. to EN 50288 and IEC 61156 excellent shielding characteristics, bandwidth 200 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Application (Ethernet, TV) Applications Connection cable and patch cord for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Ideal for all applications from Class D up to 1 GbE acc. to IEEE 802.3 ab, VoIP, PoE. A 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during operation Tensile strength (max.) 5 x overall diameter (min.) 60 N C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 10 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 50 dB Coupling attenuation up to 1,000 MHz (nominal value) 65 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Industry DataCenter 51 Electrical characteristics (HF) at 20 °C Attenuation dB/10 m typ. NEXT dB Cat. 5 max.* typ. PSNEXT dB Cat. 5 min.* typ. Cat. 5 min.* ACR dB at 10 m typ. PSACR dB at 10 m ELFEXT dB at 10 m PSELFEXT dB at 10 m Cat. 5 min.* typ. Cat. 5 min.* typ. Cat. 5 min.* typ. Cat. 5 min.* RL dB typ. Cat. 5 min.* 1 0.24 0.32 76 65 73 62 76 65 73 62 91 64 88 61 24.9 – 4 0.44 0.60 71 56 68 53 70 56 67 53 76 52 73 49 29.8 23 10 0.80 0.95 64 50 61 47 63 49 60 47 68 44 65 41 38.2 25 16 1.01 1.21 60 47 57 44 59 46 56 44 64 40 61 37 39.3 25 31.25 1.44 1.71 56 43 53 40 54 41 51 40 58 34 55 31 36.7 23.6 62.5 2.07 2.48 52 38 49 35 50 36 47 35 52 28 49 25 35 21.5 100 2.66 3.2 48 35 45 32 45 32 42 32 47 24 44 21 29.9 20.1 155 3.26 – 45 – 42 – 42 – 39 – 42 – 39 – 26.2 – 200 3.86 – 42 – 39 – 39 – 36 – 37 – 34 – 23.5 – * EN 50288-2-2(2004)/IEC 61156-6(2002) Electrical characteristics (LF) at 20 °C Printing on outer sheath DC resistance max. 145 Ω/km LEONI MegaLine D1-20 SF/U flex 4P Y SPACE Code 20123 Insulation resistance min. 5 GΩ x km "production lot code" "meter marking" Mutual capacitance approx. 47 pF/m Signal velocity (c) approx. 0.69 Colour code Propagation delay approx. 485 ns/100 m whbu/bu, whor/or, whgn/gn, whbn/bn Skew at 100 MHz approx. 15 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Certificates and approvals 1,000 V Link performance: LEONI MegaLine® systems Testing voltage Ueff Operating voltage max. 125 V and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C up to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content kg/km Colour of sheath Order no. mm kg/km 4p 5.3 32 21 ● Light grey RAL 7035 LKD 7KS5 0008 0000 4p 5.3 32 21 ● Rape yellow RAL 1021 LKD 7KS5 0009 0000 4p 5.3 32 21 ● Turquoise green RAL 6016 LKD 7KS5 0010 0000 4p 5.3 32 21 ● Sky blue RAL 5015 LKD 7KS5 0011 0000 4p 5.3 32 21 ● Flame red RAL 3000 LKD 7KS5 0012 0000 Package: Drum 1,000 m www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Frequency MHz 52 MegaLine® F10-130 S/F (L)2Y Category "7A" S0 P4 I4 C5 E5 Construction Conductor Bare copper wire, AWG 22/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.6 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Inner sheath Halogen-free, flame-retardant compound Outer sheath AL-PE Security (fire behaviour) Fire behaviour Halogen free Smoke density Calorific value (approx.) acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 3.04 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,300 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Classes D to FA Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. For use outdoors and underground installation. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 130 N 2,000 N/100 mm 20 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 70 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 53 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB PSNEXT dB ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. "7" max.* typ. Cat. "7" max.* Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* RL dB typ. Cat. "7" max.* 23 1 1.7 2 105 80 102 77 104 78 101 75 105 80 102 77 27.1 10 4.5 5.7 105 80 102 77 101 74 98 71 108 74 105 71 35.2 25 100 15.4 18.5 105 72 102 69 90 54 87 51 93 54 90 51 38.9 20.1 200 22.9 26.8 105 68 102 65 83 41 80 38 85 48 82 45 36.6 18 250 26 30.2 105 66 102 63 79 36 76 33 82 46 79 43 35.3 17.3 500 35.9 44.1 100 62 97 59 64 18 61 15 70 40 67 37 29.4 17.3 600 40.4 48.9 95 61 92 58 55 12 52 9 63 38 60 35 26.6 17.3 700 44.6 - 95 – 92 – 50 – 47 – 60 – 57 – 25.8 – 800 47.7 – 93 – 90 – 45 – 42 – 57 – 54 – 25 – 900 51.6 – 90 – 87 – 38 – 35 – 53 – 50 – 23.6 – 1000 54.8 – 88 – 85 – 33 – 30 – 48 – 45 – 22.3 – 1100 56.9 – 87 – 84 – 30 – 27 – 44 – 41 – 21.4 – 1300 61.4 – 80 – 77 – 21 – 18 – 39 – 36 – 18.3 – * EN 50288-4-1(2004)/IEC 61156-5(2002) Printing on outer sheath Electrical characteristics (LF) at 20 °C DC resistance max. 57.1 Ω/km LEONI MegaLine F10-130 S/F 4P H(L)2Y SPICE Code 04455 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 40 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –25 °C up to +70 °C For mobile operation –10 °C to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC, resistant to UV rays acc. to UL 1581 and ISO 4892 Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 12 150 45 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath ● Jet black RAL 9005 Order no. LKD 7KS7 002U 0000 MegaLine® Cu data cables Frequency MHz 54 MegaLine® F10-130 S/F QH Type KS-02YSCHQH 4x2xAWG 22/1 PIMF Category "7A" S3 P4 I4 C5 E5 Construction Conductor Bare copper wire, AWG 22/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.6 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Inner sheath Halogen-free, flame-retardant compound Armour Galvanised steel wire braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 1.53 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,300 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Classes D to FA Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. For use indoors and outdoors (with reservations) and in harsh environments. With rodent protection. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 1,400 N 3,000 N/100 mm 50 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 70 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 55 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB PSNEXT dB ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. "7" max.* typ. Cat. "7" max.* Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* RL dB typ. Cat. "7" max.* 23 1 1.7 2 105 80 102 77 104 78 101 75 105 80 102 77 27.1 10 4.5 5.7 105 80 102 77 101 74 98 71 108 74 105 71 35.2 25 100 15.4 18.5 105 72 102 69 90 54 87 51 93 54 90 51 38.9 20.1 200 22.9 26.8 105 68 102 65 83 41 80 38 85 48 82 45 36.6 18 250 26 30.2 105 66 102 63 79 36 76 33 82 46 79 43 35.3 17.3 500 35.9 44.1 100 62 97 59 64 18 61 15 70 40 67 37 29.4 17.3 600 40.4 48.9 95 61 92 58 55 12 52 9 63 38 60 35 26.6 17.3 700 44.6 - 95 – 92 – 50 – 47 – 60 – 57 – 25.8 – 800 47.7 – 93 – 90 – 45 – 42 – 57 – 54 – 25 – 900 51.6 – 90 – 87 – 38 – 35 – 53 – 50 – 23.6 – 1000 54.8 – 88 – 85 – 33 – 30 – 48 – 45 – 22.3 – 1100 56.9 – 87 – 84 – 30 – 27 – 44 – 41 – 21.4 – 1300 61.4 – 80 – 77 – 21 – 18 – 39 – 36 – 18.3 – * EN 50288-4-1(2004)/IEC 61156-5(2002) Printing on outer sheath Electrical characteristics (LF) at 20 °C DC resistance max. 57.1 Ω/km LEONI MegaLine F10-130 S/F 4P HQH SPICE Code 34455 Insulation resistance min. 5 GΩ x km "production lot code" "meter marking" Mutual capacitance approx. 40 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 11.7 185 45 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath ● Sky blue RAL 5015 Order no. LKD 7KS7 001U 0000 MegaLine® Cu data cables Frequency MHz 56 MegaLine® F10-130 S/F Vö Type KS-02YSCHVö 4x2xAWG 22/1 PIMF Category "7A" S3 P4 I4 C5 E5 Construction Conductor Bare copper wire, AWG 22/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.6 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/ 2 acc. to IEC 61034-1/2 0.80 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,300 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Classes D to FA Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. Suitable for use in harsh environments thanks to particularly robust H sheath. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 130 N 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 70 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 57 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB PSNEXT dB ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. "7" max.* typ. Cat. "7" max.* Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* RL dB typ. Cat. "7" max.* 23 1 1.7 2 105 80 102 77 104 78 101 75 105 80 102 77 27.1 10 4.5 5.7 105 80 102 77 101 74 98 71 108 74 105 71 35.2 25 100 15.4 18.5 105 72 102 69 90 54 87 51 93 54 90 51 38.9 20.1 200 22.9 26.8 105 68 102 65 83 41 80 38 85 48 82 45 36.6 18 250 26 30.2 105 66 102 63 79 36 76 33 82 46 79 43 35.3 17.3 500 35.9 44.1 100 62 97 59 64 18 61 15 70 40 67 37 29.4 17.3 600 40.4 48.9 95 61 92 58 55 12 52 9 63 38 60 35 26.6 17.3 700 44.6 - 95 – 92 – 50 – 47 – 60 – 57 – 25.8 – 800 47.7 – 93 – 90 – 45 – 42 – 57 – 54 – 25 – 900 51.6 – 90 – 87 – 38 – 35 – 53 – 50 – 23.6 – 1000 54.8 – 88 – 85 – 33 – 30 – 48 – 45 – 22.3 – 1100 56.9 – 87 – 84 – 30 – 27 – 44 – 41 – 21.4 – 1300 61.4 – 80 – 77 – 21 – 18 – 39 – 36 – 18.3 – * EN 50288-4-1(2004)/IEC 61156-5(2002) Printing on outer sheath Electrical characteristics (LF) at 20 °C DC resistance max. 57.1 Ω/km LEONI MegaLine F10-130 S/F 4P HVö SPICE Code 34455 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 40 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC, oil resistant acc. to ICEA S-82-552 (60 °C) Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 8.8 84 45 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. ● Rape yellow RAL 1021 LKD 7KS7 0089 0000 MegaLine® Cu data cables Frequency MHz 58 MegaLine® F10-115 S/F V Type KS-02YSCHV 4x2xAWG 23/1 PIMF Category "7A" S3 P4 I4 C4 E5 Construction Conductor Bare copper wire, AWG 23/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.4 mm Pair Twisting 4 pairs Overall shielding Tinned copper braiding Outer sheath Halogen-free, flame-retardant compound, wall thickness 1.0 mm Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-3-24 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.7 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,150 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Classes D to FA Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. Suitable for use in harsh environments thanks to particularly robust H sheath. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 70 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 59 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB PSNEXT dB ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* 23 Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* typ. Cat. "7" max.* RL dB 1 1.9 2 105 80 102 77 104 78 101 75 98 80 95 77 26.6 10 4.8 5.7 105 80 102 77 101 74 98 71 103 74 100 71 35.2 25 100 16.3 18.5 105 72 102 69 89 54 86 51 89 54 86 51 39.6 20.1 200 24.3 26.8 105 68 102 65 81 41 78 38 82 48 79 45 36 18 250 27.5 30.2 105 66 102 63 78 36 75 33 79 46 76 43 34 17.3 500 37.9 44.1 100 62 97 59 62 18 59 15 67 40 64 37 29 17.3 600 42.4 48.9 95 61 92 58 53 12 50 9 60 38 57 35 25.4 17.3 – 700 47.2 - 95 – 92 – 48 – 45 – 57 – 54 – 24.6 800 50.3 – 93 – 90 – 43 – 40 – 53 – 50 – 23.5 – 900 54.6 – 90 – 87 – 35 – 32 – 49 – 46 – 22.6 – 1000 58 – 88 – 85 – 30 – 27 – 44 – 41 – 21.5 – 1150 61.9 – 86 – 83 – 25 – 22 – 39 – 36 – 20.6 – *EN 50288-4-1(2004)/IEC 61156-5(2002) Printing on outer sheath Electrical characteristics (LF) at 20 °C DC resistance max. 75 Ω/km LEONI MegaLine F10-115 S/F 4P HV SPICE Code 34445 Insulation resistance min. 5 GΩ x km "VDE approval mark" "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 5 ns/100 m Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage 1,000 V max. 125 V Certificates and approvals Quality mark with production control: Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Thermal characteristics Conforms to LVD (73/23/EEC): For fixed installation –20 °C up to +60 °C For mobile operation 0 °C to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 8.1 77 37 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. ● Rape yellow RAL 1021 LKD 7KS7 0049 0000 MegaLine® Cu data cables Frequency MHz 60 MegaLine® F6-90 S/F 2Y Type KS-02YSC2Y 4x2xAWG 23/1 PIMF Category 7 S0 P3 I4 C4 E5 Construction Conductor Bare copper wire, AWG 23/1 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.4 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath PE Security (fire behaviour) Fire behaviour Halogen free Smoke density acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 900 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Classes D to F Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. For use outdoors and underground installation. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 110 N 2,000 N/100 mm 20 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 70 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 61 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m typ. NEXT dB Cat. 7 max.* typ. PSNEXT dB Cat. 7 min.* typ. ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m Cat. 7 min.* typ. Cat. 7 min.* typ. typ. Cat. 7 min.* typ. Cat. 7 min.* typ. Cat. 7 min.* RL dB Cat. 7 min.* 1 1.9 2 102 80 99 77 101 78 98 75 109 80 106 77 25.4 23 10 4.8 5.7 102 80 99 77 98 74 95 71 108 74 105 71 31.1 25 20.1 100 16.4 18.5 102 72 99 69 86 54 83 51 93 54 90 51 33.2 200 24.5 26.8 102 68 99 65 78 41 75 38 85 48 82 45 33.2 18 250 27.8 30.2 102 66 99 63 75 36 72 33 82 46 79 43 33.4 17.3 450 36.1 44.6 97 63 94 60 61 21 58 18 72 41 69 38 31.4 17.3 500 38.2 44.1 97 62 94 59 59 18 56 15 68 40 65 37 30.5 17.3 600 42.9 48.9 92 61 89 58 49 12 46 9 62 38 59 35 27.6 17.3 700 47.7 – 92 – 89 – 44 – 41 – 59 – 56 – 26.2 – 800 50.8 – 90 – 87 – 39 – 36 – 56 – 53 – 23.9 – 900 55.1 – 85 – 82 – 30 – 27 – 52 – 49 – 21.7 – *EN 50288-4-1(2004)/IEC 61156-5(2002) Electrical characteristics (LF) at 20 °C Printing on outer sheath DC resistance max. 75 Ω/km LEONI MegaLine F6-90 S/F 4P 2Y SPICE Code 03445 Insulation resistance min. 5 GΩ x km "production lot code" "meter marking" Mutual capacitance approx. 42 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.80 wh/bu, wh/or, wh/gn, wh/bn Propagation delay approx. 420 ns/100 m Skew at 100 MHz approx. 5 ns/100 m Certificates and approvals Characteristic impedance at 100 MHz 100 ± 5 Ω Link performance: LEONI MegaLine® systems Testing voltage Ueff Operating voltage 1,000 V max. 125 V and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Conforms to LVD (73/23/EEC): Thermal characteristics For fixed installation –25 °C up to +70 °C For mobile operation –10 °C to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC, resistant to UV rays acc. to UL 1581 and ISO 4892, free from paint-wetting impairment substances (e.g. silicone oil) Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 9.0 70 35 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath ● Jet black RAL 9005 Order no. LKD 7KS7 0169 0000 MegaLine® Cu data cables Frequency MHz 62 MegaLine® D1-20 SF/U 2Y Type KS-02YS(ST+C)H2Y 4x2xAWG 24/1 Category 5 S0 P0 I1 C3 E3 Construction Conductor Bare copper wire, AWG 24/1 Insulation Twisting element Twisting Cellular-PE, core-diameter: nominal value 1.1 mm Pair 4 pairs Overall shielding Aluminium-bonded polyester foil and tinned copper braiding Inner sheath Halogen-free, flame-retardant compound Outer sheath PE Security (fire behaviour) Fire behaviour Halogen free Smoke density Calorific value (approx.) acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 1.88 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 5 acc. to EN 50288 and IEC 61156 excellent shielding characteristics, bandwidth 200 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Class D up to 1 GbE acc. to IEEE 802.3 ab, VoIP, PoE. For use outdoors and underground installation. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 85 N 3,000 N/100 mm 50 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 10 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 55 dB Coupling attenuation up to 1,000 MHz (nominal value) 70 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 63 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m NEXT dB typ. PSNEXT dB typ. Cat. 5 max.* Cat. 5 min.* 1 2 2.1 75 4 3.1 4 69 10 5.1 6.3 62 50 16 7 8 58 47 31.25 9.7 11.4 53 62.5 13.2 16.5 100 17.6 21.3 155 22.3 200 26.5 ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. 5 min.* typ. Cat. 5 min.* typ. Cat. 5 min.* typ. Cat. 5 min.* RL dB typ. Cat. 5 min.* typ. Cat. 5 min.* 65 72 62 73 63 70 60 89 64 86 61 24.8 – 56 66 53 66 52 63 49 84 52 81 49 28.6 23 59 47 57 44 54 41 76 44 73 41 33.3 25 55 44 51 39 48 36 70 40 67 37 34.3 25 43 50 40 44 31 41 28 63 34 60 31 33.9 23.6 49 38 46 35 36 22 33 19 58 28 55 25 31.3 21.5 45 35 42 32 28 14 25 11 52 24 49 21 27.7 20.1 – 42 – 39 – 20 – 17 – 49 – 46 – 24.7 – – 40 – 37 – 14 – 11 – 45 – 42 – 22.4 – *EN 50288-4-1(2004)/IEC 61156-5(2002) Electrical characteristics (LF) at 20 °C Printing on outer sheath DC resistance max. 95 Ω/km LEONI MegaLine D1-20 SF/U 4P H2Y SPICE Code 00133 Insulation resistance min. 5 GΩ x km "production lot code" "meter marking" Mutual capacitance approx. 45 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.75 whbu/bu, whor/or, whgn/gn, whbn/bn Propagation delay approx. 440 ns/100 m Skew at 100 MHz approx. 15 ns/100 m Certificates and approvals Characteristic impedance at 100 MHz 100 ± 5 Ω Link performance: LEONI MegaLine® systems Testing voltage Ueff Operating voltage 1,000 V max. 125 V and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Conforms to LVD (73/23/EEC): Thermal characteristics For fixed installation –25 °C up to +70 °C For mobile operation –10 °C to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC, resistant to UV rays acc. to UL 1581 and ISO 4892 Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 8.8 70 26 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath ● Jet black RAL 9005 Order no. LKD 7KS5 001U 0000 MegaLine® Cu data cables Frequency MHz 64 MegaLine® D1-20 SF/U HQH Type KS-02YS(ST+C)HHQH 4x2xAWG 24/1 Category 5 S2 P0 I1 C3 E3 Construction Conductor Bare copper wire, AWG 24/1 Insulation Twisting element Twisting Cellular-PE, core-diameter: nominal value 1.1 mm Pair 4 pairs Overall shielding Aluminium-bonded polyester foil and tinned copper braiding Inner sheath 2 layers halogen-free, flame-retardant compound Armour Galvanised steel wire braiding Outer sheath Halogen-free, flame-retardant compound Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-1-2 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 2.1 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 5 acc. to EN 50288 and IEC 61156 excellent shielding characteristics, bandwidth 200 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Installation cable for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Class D up to 1 GbE acc. to IEEE 802.3 ab, VoIP, PoE. For universal use indoors and outdoors. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during installation after installation Tensile strength (max.) Crush strength Impact strength (number of shocks) 8 x overall diameter (min.) 4 x overall diameter (min.) 1,200 N 3,000 N/100 mm 50 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 10 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 55 dB Coupling attenuation up to 1,000 MHz (nominal value) 70 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 65 Electrical characteristics (HF) at 20 °C Attenuation dB/100 m NEXT dB typ. PSNEXT dB typ. Cat. 5 max.* Cat. 5 min.* 1 2 2.1 75 4 3.1 4 69 10 5.1 6.3 62 50 16 7 8 58 47 31.25 9.7 11.4 53 62.5 13.2 16.5 100 17.6 21.3 155 22.3 200 26.5 ACR dB at 100 m PSACR dB at 100 m ELFEXT dB at 100 m PSELFEXT dB at 100 m typ. Cat. 5 min.* typ. Cat. 5 min.* typ. Cat. 5 min.* typ. Cat. 5 min.* RL dB typ. Cat. 5 min.* typ. Cat. 5 min.* 65 72 62 73 63 70 60 89 64 86 61 24.8 – 56 66 53 66 52 63 49 84 52 81 49 28.6 23 59 47 57 44 54 41 76 44 73 41 33.3 25 55 44 51 39 48 36 70 40 67 37 34.3 25 43 50 40 44 31 41 28 63 34 60 31 33.9 23.6 49 38 46 35 36 22 33 19 58 28 55 25 31.3 21.5 45 35 42 32 28 14 25 11 52 24 49 21 27.7 20.1 – 42 – 39 – 20 – 17 – 49 – 46 – 24.7 – – 40 – 37 – 14 – 11 – 45 – 42 – 22.4 – *EN 50288-2-1(2004)/IEC 61156-5(2002) Electrical characteristics (LF) at 20 °C Printing on outer sheath DC resistance max. 95 Ω/km LEONI MegaLine D1-20 SF/U 4P HHQH SPICE Code 20133 Insulation resistance min. 5 GΩ x km "production lot code" "meter marking" Mutual capacitance approx. 45 pF/m Capacitive coupling (e) approx. 1,500 pF/km Colour code Signal velocity (c) approx. 0.75 whbu/bu, whor/or, whgn/gn, whbn/bn Propagation delay approx. 440 ns/100 m Skew at 100 MHz approx. 15 ns/100 m Certificates and approvals Characteristic impedance at 100 MHz 100 ± 5 Ω Link performance: LEONI MegaLine® systems Testing voltage Ueff Operating voltage 1,000 V max. 125 V and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Conforms to LVD (73/23/EEC): Thermal characteristics For fixed installation –20 °C up to +60 °C For mobile operation 0 °C to +50 °C Chemical characteristics Free from hazardous substances acc. to RoHS 2002/95/EC Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 11.9 194 26 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath ● Jet black RAL 9005 Order no. LKD 7KS5 002U 0000 MegaLine® Cu data cables Frequency MHz 66 MegaLine® F10-120 S/F 11Y flex Type KS-02YSC11Y 4x2xAWG 26/7 PIMF Category "7A" S1 P4 I5 C2 E5 Construction Conductor Bare stranded copper wire, AWG 26/7 Insulation Twisting element Cellular-PE, core-diameter: max. 1.05 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath PUR Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-2-2 acc. to 60754-1/2 acc. to IEC 61034-1/2 0.7 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 1,200 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Connection cable and patch cord for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Classes D to FA Multimedia (TV, video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. Suitable for use in harsh environments thanks to particularly robust PUR sheath. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during operation Tensile strength (max.) 5 x overall diameter (min.) 60 N C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 60 dB Coupling attenuation up to 1,000 MHz (nominal value) 85 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 67 Electrical characteristics (HF) at 20 °C Attenuation dB/10 m NEXT dB PSNEXT dB typ. Cat. 7A max.* typ. Cat. 7A min.* 1 0.25 0.29 100 10 0.76 0.85 99 ACR dB at 10 m typ. Cat. 7A min.* typ. Cat. 7A min.* 80 97 77 100 80 80 96 77 99 79 PSACR dB at 10 m typ. ELFEXT dB at 10 m PSELFEXT dB at 10 m RL dB Cat. 7A min.* typ. Cat. 7A min.* typ. Cat. 7A min.* typ. Cat. 7A min.* 97 77 100 80 97 80 24 23 96 77 95 74 92 71 33.9 25 20.1 100 2.49 2.78 95 72 92 69 93 70 90 69 69 54 66 51 38.3 200 3.69 4.01 92 68 89 65 88 64 85 65 65 48 62 45 35.3 18 250 4.18 4.53 90 66 87 63 86 62 83 63 62 46 59 43 32.9 17.3 500 5.6 6.62 83 62 80 59 78 55 75 59 54 40 51 37 29.7 17.3 600 6.74 7.33 81 61 78 58 74 53 71 58 50 38 47 35 30.6 17.3 700 7.32 – 80 – 77 – 72 – 69 – 50 – 47 – 31 – 800 7.89 – 77 – 74 – 69 – 66 – 50 – 47 – 26.7 – 900 8.5 – 75 – 72 – 67 – 64 – 34 – 31 – 28.6 – 1000 9.11 – 74 – 71 – 65 – 62 – 32 – 29 – 27.5 – 1100 9.5 – 72 – 69 – 63 – 60 – 28 – 25 – 26.9 – 1200 9.9 – 70 – 67 – 61 – 58 – 24 – 21 – 26.3 – *EN 50288-4-2(2004)/IEC 61156-6(2002) Electrical characteristics (LF) at 20 °C Chemical characteristics DC resistance max. 145 Ω/km Free from hazardous substances acc. to RoHS 2002/95/EC, Insulation resistance min. 5 GΩ x km oil resistant acc. to EN 60811-2-1, Mutual capacitance approx. 44 pF/m resistant to microbes acc. to DIN VDE 0282, Signal velocity (c) approx. 0.78 resistant to chemicals, Propagation delay approx. 440 ns/100 m resistant to hydrolysis acc. to DIN 53504, Skew at 100 MHz approx. 2.5 ns/100 m free from paint-wetting impairment substances (e.g. silicone oil) Characteristic impedance at 100 MHz 100 ± 5 Ω Testing voltage Ueff Operating voltage max. 1,000 V Printing on outer sheath 125 V LEONI MegaLine F10-120 S/F flex 4P 11Y SPICE Code 14525 "production lot code" "meter marking" Thermal characteristics For fixed installation –40 °C up to +70 °C Colour code For mobile operation –10 °C to +50 °C wh/bu, wh/or, wh/gn, wh/bn Certificates and approvals Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Conforms to LVD (73/23/EEC): Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 6.4 45 23,5 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. ● Rape yellow RAL 1021 LKD 7KS7 0090 0000 MegaLine® Cu data cables Frequency MHz 68 MegaLine® F6-70 S/F 11Y flex Type KS-02YSC11Y 4x2xAWG 24/7 PIMF Category 7 S2 P3 I4 C3 E5 Construction Conductor Bare stranded copper wire, AWG 24/7 Insulation Twisting element Cellular-PE, core-diameter: nominal value 1.55 mm Pair Individual shielding Twisting Aluminium-bonded polyester foil, metal side outside (PiMF) 4 pairs Overall shielding Tinned copper braiding Outer sheath PUR, flame-retardant Security (fire behaviour) Fire behaviour Flame retardancy Halogen free Smoke density Calorific value (approx.) acc. to IEC 60332-1-2 acc. to IEC 60754-1/2 acc. to IEC 61034-1/2 0.99 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 7 acc. to EN 50288 and IEC 61156 excellent NEXT, low attenuation, excellent shielding characteristics (shielding of pairs and overall shielding), low skew, bandwidth 700 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Connection cable and patch cord for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Classes D to F Multimedia (video, data, voice) >10 GbE acc. to IEEE 802.3 an, cable sharing, VoIP, PoE. Suitable for use in harsh environments thanks to particularly robust PUR sheath. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during operation Tensile strength (max.) Crush strength Impact strength (number of shocks) 5 x overall diameter (min.) 100 N 1,000 N/100 mm 10 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 5 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 60 dB Coupling attenuation up to 1,000 MHz (nominal value) 90 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 69 Electrical characteristics (HF) at 20 °C Attenuation dB/10 m typ. Cat. 7 max.* NEXT dB typ. PSNEXT dB Cat. 7 min.* typ. Cat. 7 min.* ACR dB at 10 m typ. Cat. 7 min.* PSACR dB at 10 m typ. Cat. 7 min.* ELFEXT dB at 10 m typ. Cat. 7 min.* PSELFEXT dB at 10 m typ. RL dB Cat. 7 min.* typ. Cat. 7 min.* 1 0.23 0.29 90 80 87 77 90 80 87 77 90 80 87 77 23.3 – 4 0.4 0.55 90 80 87 77 90 79 87 77 90 80 87 77 25 23 10 0.63 0.85 90 80 87 77 89 79 86 77 90 74 87 71 30 25 16 0.79 1.08 90 80 87 77 89 79 86 77 90 70 87 67 30 25 20 0.91 1.21 90 80 87 77 89 79 86 77 85 68 82 65 30 25 100 2.07 2.78 81 72.4 78 69 79 70 76 69 64 54 61 51 24 20.1 200 3.07 4.01 76 67.9 73 65 73 64 70 65 57 48 54 45 24 18 250 3.43 4.53 74 66.5 71 63 71 62 68 63 53 46 50 43 24 17.3 500 4.77 6.62 70 61.9 67 59 65 55 62 59 45 40 42 37 21 17.3 600 5.23 7.33 68 60.8 65 58 63 53 60 58 42 38 39 35 21 17.3 700 5.65 – 65 – 62 – 59 – 56 – 39 – 36 – 19 – *EN 50288-4-2(2004)/IEC 61156-6(2002) Electrical characteristics (LF) at 20 °C Chemical characteristics DC resistance max. 84 Ω/km Free from hazardous substances acc. to RoHS 2002/95/EC, Insulation resistance min. 5 GΩ x km oil resistant acc. to EN 60811-2-1, Mutual capacitance approx. 42.5 pF/m resistant to ozone acc. to EN 60811, Signal velocity (c) approx. 0.72 resistant to microbes acc. to DIN VDE 0282, Propagation delay approx. 460 ns/100 m resistant to chemicals, Skew at 100 MHz approx. 7 ns/100 m resistant to hydrolysis acc. to DIN 53504, Characteristic impedance at 100 MHz 100 ± 5 Ω free from paint-wetting impairment substances (e.g. silicone oil) Testing voltage Ueff Operating voltage 1,000 V max. 125 V Printing on outer sheath LEONI MegaLine F6-70 S/F flex 4P 11Y SPICE Code 23435 Thermal characteristics "production lot code" "meter marking" For fixed installation –40 °C up to +70 °C For mobile operation –10 °C to +50 °C Colour code wh/bu, wh/or, wh/gn, wh/bn Certificates and approvals Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Conforms to LVD (73/23/EEC): Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 8.8 73 35 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. ● Rape yellow RAL 1021 LKD 7KS7 0139 0000 MegaLine® Cu data cables Frequency MHz 70 MegaLine® D1-20 S/U 11Y superflex Type KS-6Y3GC11Y 4x2xAWG 26/19 Category 5 S1 P0 I1 C2 E4 Construction Conductor Bare stranded copper wire, AWG 26/19 Insulation Twisting element Twisting Tape FEP, core-diameter: nominal value 1.0 mm Pair 4 pairs Fleece foil Inner sheath Tape EPDM Fleece foil Overall shielding Tinned copper braiding, approx. 90% optically opaque Outer sheath PUR Security (fire behaviour) Fire behaviour Flame retardancy Calorific value (approx.) acc. to IEC 60332-2-2 0.7 MJ/m S 1 IEC 603322-2 2 IEC 603321-2 3 IEC 603323-24 4 EFP Grade 1 5 EFP Grade 2 Performance (cabling class, bandwidth) Performance Better than Category 5 acc. to EN 50288 and IEC 61156 excellent shielding characteristics, bandwidth 100 MHz P 1 > Class E > 250 MHz 2 > Class E A > 500 MHz 3 > Class F > 600 MHz 4 5 > Class FA > Class "G" > 1000 MHz > 1200 MHz Industrial application (Ethernet, TV) Applications Connection cable and patch cord for use in structured cabling systems acc. to ISO/IEC 11801 and EN 50173 (2nd edition) as well as ISO/IEC 24702 and EN 50173-3. Ideal for all applications from Class D up to 1 GbE acc. to IEEE 802.3 ab, VoIP, PoE. Suitable for use in harsh environments thanks to EPDM inner sheath and particularly robust PUR outer sheath. Suitable for use with drag chains. I 1 > 100 MbE 2 > 1 GbE 3 Up to 10 GbE 4 > 10 GbE 5 > 10 GbE TV Construction (conductor dimensions, tensile strength) Mechanical characteristics Bending radius during operation Tensile strength (max.) Crush strength Impact strength (number of shocks) 5 x overall diameter (min.) 60 N 2,000 N/100 mm 20 C 1 AWG 27 2 AWG 26/25 3 AWG 24 4 AWG 23 5 AWG 22 3 > 60 dB 4 > 70 dB 5 > 80 dB EMC (coupling attenuation) Electromagnetic behaviour Transfer impedance at 10 MHz (nominal value) 25 mΩ/m Shielding attenuation up to 1,000 MHz (nominal value) 55 dB Coupling attenuation up to 1,000 MHz (nominal value) 75 dB E 1 > 40 dB 2 > 50 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 71 Electrical characteristics (HF) at 20 °C Attenuation dB/10 m typ. NEXT dB Cat. 5 max.* typ. PSNEXT dB Cat. 5 min.* ACR dB at 10 m typ. Cat. 5 min.* typ. Cat. 5 min.* PSACR dB at 10 m ELFEXT dB at 10 m typ. Cat. 5 min.* typ. Cat. 5 min.* PSELFEXT dB at 10 m typ. Cat. 5 min.* RL dB typ. Cat. 5 min.* 1 0.22 0.32 80 65 77 62 80 65 77 62 80 64 77 61 27 – 4 0.56 0.60 67 56 64 53 67 56 64 53 69 52 66 49 26 23 10 1 1.05 63 50 60 47 62 49 59 47 61 44 65 58 30 25 16 1.35 1.45 61 47 58 44 60 46 57 44 56 40 53 37 30 25 20 1.5 1.6 59 46 56 43 58 44 55 43 53 38 50 35 30 25 31.25 1.95 2 57 43 54 40 55 41 52 40 48 34 45 31 30 23.6 62.5 2.95 3 52 38 49 35 50 36 47 35 43 28 40 25 28 21.5 100 3.95 4 45 35 42 32 42 32 39 32 38 24 35 21 26 20.1 * Based on EN 50288-2-2(2004)/IEC 61156-6(2002) Electrical characteristics (LF) at 20 °C Chemical characteristics DC resistance max. 130 Ω/km Free from hazardous substances acc. to RoHS 2002/95/EC, Insulation resistance min. 5 GΩ x km oil resistant acc. to EN 60811-2-1, Mutual capacitance approx. 50 pF/m resistant to ozone acc. to EN 60811, Signal velocity (c) approx. 0.68 resistant to microbes acc. to DIN VDE 0282, Propagation delay approx. 490 ns/100 m resistant to chemicals, Skew at 100 MHz approx. 15 ns/100 m resistant to hydrolysis acc. to DIN 53504, Characteristic impedance at 100 MHz 100 ± 5 Ω free from paint-wetting impairment substances (e.g. silicone oil) Testing voltage Ueff Operating voltage 1,000 V max. 125 V Printing on outer sheath LEONI MegaLine D1-20 S/U superflex 4P 11Y SPICE Code 10124 Thermal characteristics "production lot code" "meter marking" For fixed installation –40 °C up to +85 °C For mobile operation 0 °C to +50 °C Colour code gr/or, bl/rd, gn/ye, bu/bn Certificates and approvals Link performance: LEONI MegaLine® systems and further commercial connector systems Inspection certificates: acc. to DIN 55350-18-4.2.1/EN 10204 Conforms to LVD (73/23/EEC): Dimensions Outer diam. approx. Weight approx. Cu content mm kg/km kg/km 6.8 58 28,6 4p Package: Drum 1,000 m www.leoni-infrastructure-datacom.com Colour of sheath Order no. ● Rape yellow RAL 1021 LKD 7KS5 0051 0000 MegaLine® Cu data cables Frequency MHz 72 VarioKeystone Cu connectivity ® www.leoni-infrastructure-datacom.com Office Industry DataCenter VarioKeystone® Cu connectivity VarioKeystone® The innovative connection concept. 74 VarioKeystone® One click takes you to the next generation. 75 VarioKeystone® Benefits that speak for themselves. 76 VarioKeystone® No limits. 77 VarioKeystone® System overview 78 o dc i Cable plugs • Cable plug Cat. 7/6A • Crossconnect cable plug Cat. 7 o dc i Jack modules • Jack module 4K7 Cat. 7 • Jack module RJ45 Cat. 6A 81 o dc i Double modules RJ45 • Double module Ethernet • Double module ISDN • Double module Ethernet/ISDN 82 o dc i Link extender Class EA 83 o dc i Telephone patch panel 1 RU, 25 ports 83 o dc i Patch panels 19" • Patch panel 19" fixed 6x4 • Patch panel 19" telescopic 6x4 84 dc Modular patch panel 19"/1 RU For VarioKeystone® single or double modules 85 dc Modular patch panel 19“/1 RU For VarioKeystone® link extenders 86 i DIN rail housing Dual, with double DIN rail clip 87 i Industrial housing IP44 For wall mounting 88 i Industrial housing IP65/67 Han® 3 A, equipped with VarioKeystone® RJ45 88 o dc i Wall outlets For VarioKeystone® jack modules 89 VarioKeystone® accessories • Dust protective cap • Dummy cover • Dust protective plug • Measuring cable set Tera – Tera • Measuring cable set RJ45 – RJ45 • Measuring cable set Tera – Crossconnect 90 o dc i Cable assembly tools • Parallel pliers • UTP/FTP/foil stripping tool • Stripper • Release tool • Copper tape • Assembly set 1/2 91 o Office o dc i dc i DataCenter Industry www.leoni-infrastructure-datacom.com 80 VarioKeystone® Cu connectivity 73 74 VarioKeystone® The innovative connection concept Long downtimes and high installation costs are constant The basic configuration consisting of a Category 7 data cable challenges for those in charge of IT when the existing and cable connector is completed by simply snapping on the cabling infrastructure is changed. The problem will desired jack module. worsen in future as a result of the constantly increasing requirements for data transmission. The user can choose between RJ45 jack modules according to Category 6A (IEC 60603-7-51) and 4K7 (interface according Against this background, cabling systems that allow upgrades to IEC 61076-3-104) according to Category 7. and migrations to be performed in an extremely short time without costly re-installation take on greater significance. VarioKeystone® is a cabling system whose modular design allows migration from Category 6 to Category 7 at any time without the necessity of re-installing the existing cabling infrastructure. www.leoni-infrastructure-datacom.com Office Industry DataCenter 75 VarioKeystone® VarioKeystone® Cu connectivity One click takes you to the next generation VarioKeystone® release tool – for easy and fast migration "with a click" For migration, the new release tool allows the cable plug and extremely short link lengths of one metre to be realised. jack module to be separated safely, rapidly and effortlessly The permanent link of Class EA is reached with considerable using lever action. reserves of typically 6 dB in near-end crosstalk (NEXT). In this way, the existing cabling system can be adapted Modular patch panels, wall outlets, floorbox solutions and to fit the new requirements in a few minutes "with a click". consolidation point housings complete the product range. Easy installation is particularly useful in DataCenters where system migrations must be achieved with zero downtime. VarioKeystone® combines a secure future with flexibility while Pre‑assembled trunks help to keep the necessary assembly ensuring maximum performance and ease of assembly. times to a minimum. The cable links in the DataCenter are often below the 15 m mark. The standards speak of a "short link" here, and this is where the men are separated from the boys in terms of product technology. The VarioKeystone® system allows www.leoni-infrastructure-datacom.com 76 VarioKeystone® Benefits that speak for themselves + High performance + Flexibility • For all classes (D to F) and categories (5 to 7) • Thanks to interchangeable jack modules • Thanks to the release tool • For permanent link above 1 m with class EA • Thanks to the extension option with • High EMC, alien crosstalk by design • PoE and PoE plus • Thanks to modular and telescopic patch panels • Extremely sturdy thanks to solid metal design • Thanks to pre-assembled links • Excellent strain relief incl. Multimedia +40 GbE the VarioKeystone® link extender + Cost-efficiency + Future-proofing • Thanks to unique, multi-use cable connection • Thanks to interchangeable jack modules with different • Thanks to upward and downward compatibility • Thanks to modular and telescopic patch panels • Thanks to conformity with standards • Thanks to low maintenance and service costs • Thanks to independent certification • Thanks to short upgrade times using the release tool • Thanks to short mounting times • Thanks to pre-assembled links (minimal downtime) (maintains value) performance levels and mating faces • Thanks to a variety of interchangeable jack modules different performance levels and mating faces (acc. to standard or customer-specific) www.leoni-infrastructure-datacom.com Office Industry DataCenter 77 VarioKeystone® VarioKeystone® Cu connectivity No limits Cat. 5/6 Cat. 6A Cat. 7 Upward compatibility when it comes to performance… …AND what the future holds. VarioKeystone® is the innovative connection concept for structured and universal IT cabling systems. The modular component design means that jack modules can be exchanged at any time with minimal effort. www.leoni-infrastructure-datacom.com 78 VarioKeystone® Cu connectivity System overview VarioKeystone® is the innovative connection concept The link extender is an easy means of extending cable links for building cabling systems. The modular design without any significant reduction in performance. of the components enables both current and future requirements to be met. VarioKeystone® maintains the value of your investments – in the long term. The modular design of the available RJ45 jack modules Cat. 6A (IEC 60603-7-51) and 4K7 (IEC 61076-3-104) allows them to be replaced with relatively little effort. This makes it easy to choose the right mating face. Pre-assembled cable Cable plug MegaLine® G12-150 S/F MegaLine® F10-130 S/F MegaLine® F10-115 S/F Cat. 7 Cable plug Cat. 6A Crossconnect cable plug Cat. 7 Cable Cable plugs www.leoni-infrastructure-datacom.com Office Industry DataCenter 79 Jack module Cat. 6A Cat. 7 (Tera) Cat. 6A (RJ45) see page 80 see page 80 see page 81 see page 81 Cat. 5/Cat. 3 (double module RJ45) (ETH/ETH) see page 82 (ETH/ISDN*) see page 82 (ISDN/ISDN) see page 82 ✔ ✔ ✔ ✔ ✔ The following performance classes are reached with the cable plug/jack module combination Class FA ✔ Class F ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ (channel) Class EA (PL) Class EA (channel) Class E Class D Class C ✔ VarioKeystone® wall outlets Jack module 4K7 Cat. 7 VarioLine® UF underfloor systems Jack module RJ45 Cat. 6A VarioLine® CP consolidation point housing Double module RJ45 VarioKeystone® modular panel Link extender 19"/1 RU Class EA Jack modules www.leoni-infrastructure-datacom.com Housing VarioKeystone® Cu connectivity Cable plug Cat. 7 80 VarioKeystone®  Cable plugs Category 7/6A Crossconnect cable plug Cat. 7 red contact block Cable plug Cat. 6A aqua contact block Cable plug Cat. 7 white contact block VarioKeystone® Cable plug VarioKeystone® Crossconnect cable plug Description Description Interface to the individually interchangeable VarioKeystone® Interface to the individually interchangeable VarioKeystone® jack module. The cable plug enables generic transmission jack module. The cable plug enables generic transmission links far exceeding the requirements for Class F to be achieved. links far exceeding the requirements for Class F to be achieved. The mating face can also be identified later without any The mating face can also be identified later without any additional installation effort. additional installation effort. ■■ Various mating faces available ■■ Various mating faces available ■■ Easy and quick assembly ■■ Easy and quick assembly ■■ Required for extending links in combination with the link extender Construction Construction Material Full metal; die-cast zinc, nickel-plated Material Full metal; die-cast zinc, nickel-plated Wiring 4 pairs via punchdown method Wiring 4 pairs via punchdown method Strain relief Via cable ties Strain relief Via cable ties Shielding Large-surface 360° shield connection Shielding Large-surface 360° shield connection Contact block: white/aqua Electrical values Contact block: red Electrical values Category 7/6A Standards Standards ■■ ISO/IEC 11801 ■■ ISO/IEC 11801 ■■ EN 50173-1 ■■ EN 50173-1 Article Category 7 Cat. Order no. Article Category Order no. 9.0 mm hole for AWG 23 10.0 mm hole for AWG 22 VarioKeystone® Crossconnect (9.0 mm hole for AWG 23) Cat. 7 LKD 9A46 0055 0000 VarioKeystone® Crossconnect (10.0 mm hole for AWG 22) Cat. 7 LKD 9A46 0058 0000 VarioKeystone® cable plug – white Cat. 7 LKD 9A46 0054 0000 LKD 9A46 0057 0000 VarioKeystone® cable plug – aqua Cat. 6A LKD 9A46 0129 0000 LKD 9A46 0130 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 81 VarioKeystone®  Jack modules VarioKeystone® Cu connectivity Category 7/6A Jack module Cat. 6A aqua VarioKeystone® Jack module 4K7 Cat. 7 VarioKeystone® Jack module RJ45 Cat. 6A Description Description For transmitting analogue and digital voice, image and data For transmitting analogue and digital voice, image and data signals. signals. The performance corresponds to Class F up to 600 MHz The performance corresponds to Category 6A up to 500 MHz. according to EN 50173-1. Aufbau Construction Material Full metal; die-cast zinc, nickel-plated Material Full metal; die-cast zinc, nickel-plated Installation dimen- According to the installation dimensions Installation dimen- According to the installation dimensions of the jack module RJ45 and thus sions of the jack module 4K7 and thus sions interchangeable interchangeable Wiring 4 pairs via cable plug Wiring 4 pairs via cable plug Connection Jack 4K7 Connection Jack RJ45 Standards ■■ ISO/IEC 11801 Standards ■■ EN 50173-1 ■■ ISO/IEC 11801 ■■ EN 61076-3-104 ■■ EN 50173-1 ■■ IEC 60603-7-51 Accessories see from page 90 Installed by pushing onto the cable plug. Accessories Easy replacement using the release tool. Installed by pushing onto the cable plug. see from page 90 Easy replacement using the release tool. Article Category Order no. Article Category Order no. VarioKeystone® jack module 4K7 Cat. 7 LKD 9A46 0061 0000 VarioKeystone® jack module RJ45 – aqua Cat. 6A LKD 9A46 0128 0000 www.leoni-infrastructure-datacom.com 82 VarioKeystone®  Double modules RJ45 Category 6/3 Double module Ethernet VarioKeystone® Double module Ethernet VarioKeystone® Double module ISDN VarioKeystone® Double module Ethernet/ISDN Double module ISDN Double module Ethernet/ISDN Description Construction The double module RJ45 allows reversible cable sharing Material Full metal; die-cast zinc, nickel-plated by splitting the four pairs between two RJ45 jacks. Wiring 2x2 pairs via cable plug Assignment See table Electrical values See table The transmission data corresponds to Cat. 6/3. Subsequent retrofitting to Cat. 7 is possible at any time if the cable is fitted with Category 7 cable plugs. The zinc die-cast housing offers maximum shielding and excellent stability. ■■ Fits all V ­ arioKeystone® patch panels ■■ Can be used in the VarioKeystone® triple data outlet Standards ■■ ISO/IEC 11801 ■■ EN 50173-1 ■■ IEC 60603-7-5, IEC 60603-7-3 in combination with the dummy cover (see from page 89) Fig. Article Assignment Category Order no. 1 VarioKeystone® Double module Ethernet RJ45 jack A RJ45 jack B 1.2 – 3.6 1.2 – 3.6 Cat. 6 LKD 9A46 0093 0000 2 VarioKeystone® Double module ISDN RJ45 jack A RJ45 jack B 3.6 – 4.5 3.6 – 4.5 Cat. 3 LKD 9A46 0124 0000 3 VarioKeystone® Double module Ethernet/ISDN RJ45 jack A RJ45 jack B 1.2 – 3.6 3.6 – 4.5 Jack A Jack B Cat. 6 Cat. 3 LKD 9A46 0096 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 83 VarioKeystone®  Telephone patch panel Class EA 1 RU, 25 ports VarioKeystone® Cu connectivity VarioKeystone®  Link extender VarioKeystone® Link extender VarioKeystone® Telephone patch panel Description Description For extending an existing cable infrastructure to up to 90 m without Patch panel for transmitting analogue and digital telephone transmission losses on the basis of the VarioKeystone® system. signals. Its small size means that the extender can also be retrofitted With integrated cable management for easy and safe installation. in the cable duct at any time. Note that it is necessary to connect a standard cable plug on one side and the Crossconnect plug Construction on the other. This plug differs from the cable plug in that Housing Steel panel it has a red LSA insert. Depending on the link used, the link Colour Light grey RAL 7035 performance to be achieved is suitable for Class E or Class EA. Labelling 1–25 Capacity 25 x 8 IDC terminals for max. 100 DA Each pair is continued with separate shielding, which means (AWG 24 – AWG 23) that the cable transmission data are only affected minimally. Strain relief Via cable ties This means that it is possible to continue transferring 10 Gigabit Cable entry Over the entire width of the cable Ethernet via an extended link. management rail Construction Layout 25 ports (TERA 4 p) Panel 44 mm x 485 mm x 100 mm (H x W x D) Material Full metal; die-cast zinc, nickel-plated Shielding Large-surface 360° shield connection Dimensions Electrical values Class EA 19"/1 RU 100 mm installation depth Standards ■■ ISO/IEC 11801 ■■ EN 50173-1 Article Class Order no. Article Order no. VarioKeystone® Link extender (1 piece) Class E A LKD 9A46 0062 0000 VarioKeystone® Telephone patch panel (1 piece) LKD 9A62 0002 0000 www.leoni-infrastructure-datacom.com 84 VarioKeystone®  Patch panel 19" fixed/telescopic VarioKeystone® Patch panel 19" fixed 6x4 VarioKeystone® Patch panel 19" telescopic 6x4 Description Description The patch panel can be equipped with up to 24 jack modules. The patch panel can be equipped with up to 24 jack modules. For holding different module types simultaneously (RJ45, 4K7, For holding different module types simultaneously (RJ45, 4K7, double modules). double modules). As a result of its simple construction, this patch panel provides a In the extended state, the drawer can be inclined downwards, reasonably priced alternative to telescopic patch panels. thus making the various jack modules easy to change. Easy opening and closing of the drawer is ensured by a captive screw connection accessible on the front. Construction Construction Housing Full metal Housing Full metal Colour Light grey RAL 7035 Colour Light grey RAL 7035 Capacity Up to 24 jack modules: 4K7/RJ45 Capacity Up to 24 jack modules: 4K7/RJ45 4 jack modules (or two double modules) 4 jack modules (or two double modules) can be mounted per window can be mounted per window Strain relief Via cable ties Strain relief Via cable ties Earthing Via screw on the rear of the panel Earthing Via riveted cable shoe on the left-hand Cable entry Over the entire width of the cable management rail and right-hand side of the drawer Cable entry Over the entire width of the cable management rail Dimensions Dimensions 19"/1 RU 19"/1 RU 100 mm installation depth 100 mm installation depth Article Order no. Article Order no. VarioKeystone® Patch panel fixed 6x4 (1 piece) LKD 9A67 0006 0000 VarioKeystone® Patch panel telescopic 6x4 (1 piece) LKD 9A67 0000 0000 www.leoni-infrastructure-datacom.com Office DataCenter Industry Industry 85 VarioKeystone®  Modular patch panels 19"/1 RU Fig. 1 Patch panel 16 EM, fully mounted Fig. 2 Patch panel 24 EM, fully mounted VarioKeystone® Patch panel 16 EM VarioKeystone® Patch panel 24 EM VarioKeystone® Patch panel 8 DM VarioKeystone® Patch panel 12 DM Fig. 3 Patch panel 8 DM, fully mounted Fig. 4 Patch panel 12 DM, fully mounted Description Cable socket carrier Modular three-part universal patch panel for 16 or 24 Vario ■■ Unit for cable plugs Keystone® ports for installing single modules (EM) or double ■■ Mounted outside the cabinet or base carrier modules (DM). Modules can be hot-swapped. ■■ Is inserted into the rear of the base carrier following mounting ■■ Secured using slide latch ■■ Potential equalisation by means of two threaded bolts M5 ■■ Allows the integration of an electronic cable management system ■■ and/or two earth lugs Can be replaced with single/double modules by changing the stainless steel front panel Stainless steel front cover (depending on design) Patch panel 16 EM Cut-outs for 16 single modules Patch panel set Patch panel 24 EM Cut-outs for 24 single modules Consisting of base carrier, cable socket carrier, stainless steel Patch panel 8 DM Cut-outs for 8 double modules front panel Patch panel 12 DM Cut-outs for 12 double modules Base carrier Construction ■■ For holding a cable socket carrier ■■ Is pre-installed in the cabinet or rack Strain relief Via cable ties Cable entry Over the entire width of the cable management rail Dimensions Labelling Using labelling strip made from aluminium, self-adhesive (must be ordered separately, see table) 44 mm x 483 mm x 163 mm (H x W x D) Accessories (must be ordered separately – from page 80) Single modules: RJ45 Cat. 6A , 4K7 (TERA) Double modules: Ethernet/Ethernet, Ethernet/telephony, telephony/telephony Fig. Article Capacity Ports Order no. 1 VarioKeystone® Patch panel 16 EM For installing 16 single modules: RJ45 Cat. 6A/4K7 (TERA) For 16 VarioKeystone® ports LKD 9A67 0019 0000 2 VarioKeystone® Patch panel 24 EM For installing 24 single modules: RJ45 Cat. 6A/4K7 (TERA) For 24 VarioKeystone® ports LKD 9A67 0011 0000 3 VarioKeystone® Patch panel 8 DM For installing 8 double modules: Ethernet/Ethernet, Ethernet/telephony, telephony/telephony For 16 VarioKeystone® ports LKD 9A67 0022 0000 4 VarioKeystone® Patch panel 12 DM For installing 12 double modules: Ethernet/Ethernet, Ethernet/telephony, telephony/telephony For 24 VarioKeystone® ports LKD 9A67 0020 0000 – VarioKeystone® Labelling strip www.leoni-infrastructure-datacom.com LKD 9A67 0024 0000 VarioKeystone® Cu connectivity for VarioKeystone® single or double modules 86 VarioKeystone®  Modular patch panels 19"/1 RU for VarioKeystone® link extenders Base carrier Patch panel 24 EX, fully mounted Cable socket carrier VarioKeystone® Patch panel 16 EX VarioKeystone® Patch panel 24 EX Stainless steel front panel Description Cable socket carrier Modular three-part universal patch panel for 16 or 24 ■■ Unit for holding the cable plugs VarioKeystone® ports for holding the VarioKeystone® link ■■ Mounted outside the cabinet or base carrier extender (EX). ■■ Is inserted into the rear of the base carrier following mounting ■■ Secured using slide latch ■■ Potential equalisation by means of two threaded bolts M5 ■■ Allows the integration of an electronic cable management system ■■ and/or two earth lugs Can be replaced with single/double modules by changing the stainless steel front panel Stainless steel front panel Patch panel set Patch panel 16 EX Cut-outs for 16 link extenders Patch panel 24 EX Cut-outs for 24 link extenders Consisting of base carrier, cable socket carrier, stainless steel Construction front panel Base carrier ■■ For holding a cable socket carrier ■■ Is pre-installed in the cabinet or rack Strain relief Via cable ties Cable entry Over the entire width of the cable management rail Dimensions 44 mm x 483 mm x 163 mm (H x W x D) Labelling Accessories Using labelling strip made from aluminium, self-adhesive VarioKeystone® link extender (must be ordered separately) see page 82 (must be ordered separately, see table) Article Capacity Ports Order no. VarioKeystone® Patch panel 16 EX For installing extension modules: VarioKeystone® link extender For 16 VarioKeystone® ports LKD 9A67 0023 0000 VarioKeystone® Patch panel 24 EX For installing extension modules: VarioKeystone® link extender For 24 VarioKeystone® ports LKD 9A67 0021 0000 VarioKeystone® Labelling strip LKD 9A67 0024 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 87 VarioKeystone®  DIN rail housing VarioKeystone® Cu connectivity Dual, with DIN rail clip VarioKeystone® DIN rail housing, dual Description With DIN rail clip for holding up to 2 ­VarioKeystone® jack modules. The housing is mounted by snapping it onto the existing DIN rails. The metal housing is particularly suitable for use in industrial environments (IP20). Construction Material Steel panel, powder-coated Colour Light grey RAL 7035 Capacity For up to 2 VarioKeystone® jack modules Dimensions 85 mm x 35 mm x 95 mm (H x W x D) Article Order no. VarioKeystone® DIN rail housing, dual (1 piece) LKD 9A46 0097 0000 www.leoni-infrastructure-datacom.com 88 VarioKeystone®  Industrial housing IP44 VarioKeystone®  Industrial housing IP65/67 for wall mounting Han® 3 A, equipped with VarioKeystone® RJ45 VarioKeystone® Industrial housing IP44 VarioKeystone® Industrial housing IP65/67 Description Description Suitable for up to 2 ­VarioKeystone® jack modules Extremely robust housing, which means it can also be used near (RJ45, 4K7 double module). welding robots. The robust plastic housing is suitable for use in harsh industrial environments (IP44). The wall housing is lockable and prevents Construction unauthorised use of the data network. Interface Han® 3 A, lockable Housing Steel panel, powder-coated Colour Light grey RAL 7035 Protection class IP65/IP67 Construction Material Plastic Colour Light grey RAL 7035 Housing Lockable, unequipped Connections Mounting Via 4 screws ■■ Includes 2 VarioKeystone® cable plugs (Cat. 7) and jack module RJ45 (Cat. 6A) Dimensions ■■ Quick connection method for the horizontal cable via VarioKeystone® modules 120 mm x 120 mm x 90 mm (H x W x D) ■■ Office patch cord can be plugged in (e.g. for test purposes) Article Order no. Article Order no. VarioKeystone® Industrial housing IP44 (1 piece) LKD 9A46 0111 0000 VarioKeystone® Industrial housing IP65/67 LKD 9ZE9 7004 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 89 VarioKeystone®  Wall outlets Fig. 1 Wall outlet 50 x 50/single gang Fig. 2 Wall outlet 50 x 50/double gang VarioKeystone® Cu connectivity For VarioKeystone® jack modules Fig. 3 Wall outlet 50 x 50/triple gang VarioLine® Wall outlets 50 x 50 Description Installation dimensions Wall outlets for installation in commercially available 50 x 50 mm 50 mm x 50 mm (H x W), downward inclination of 30° cover frames for equipping with VarioKeystone® jack modules. Accessories (optional) Housing VarioKeystone® cover frame, single and double gang Housing body Full metal; die-cast zinc, nickel-plated 40 mm surface-mounted housing incl. single-gang flush- Colours Pure white RAL 9010 mounted cover frame or Oyster white RAL 1013 Spacer frame for single-gang surface-mounted housing, 10 mm Labelling Fig. Via labelling field Designation 1 VarioKeystone® Wall outlet 50 x 50/single gang (1 piece) 2 VarioKeystone® Wall outlet 50 x 50/double gang (1 piece) 3 VarioKeystone® Wall outlet 50 x 50/triple gang (1 piece) Colour Order no. ● Oyster white RAL 1013 LKD 9A46 0105 0000 Colour Order no. ● Pure white RAL 9010 LKD 9A46 0108 0000 LKD 9A46 0107 0000 LKD 9A46 0104 0000 LKD 9A46 0106 0000 LKD 9A46 0109 0000 – Single-gang flush-mounted cover frame (1 piece) LKD 9A41 0002 0000 LKD 9A41 0003 0000 – Double-gang flush-mounted cover frame (1 piece) LKD 9A41 0004 0000 LKD 9A41 0005 0000 – 40 mm surface-mounted housing incl. single-gang flush-mounted cover frame (1 piece) ● Pure white LKD 9A46 0087 0000 RAL 9010 LKD 9A46 0086 0000 – Spacer frame for single-gang surface-mounted housing, 10 mm (1 piece) LKD 9A46 0089 0000 LKD 9A46 0088 0000 www.leoni-infrastructure-datacom.com ● Oyster white RAL 1013 90 VarioKeystone®  Accessories VarioKeystone® Dust protective cap VarioKeystone® Dummy cover Description ■■ ■■ VarioKeystone® Dust protective plug Description Description For modules/link extenders or ■■ For wall outlets ■■ For 4K7 module For cable plugs ■■ White or black ■■ White or black Designation Version For modules/ VarioKeystone® link extenders Dust protective (50 pieces) cap For cable plugs (1 piece) Order no. Designation Order no. Designation Order no. LKD 9A46 0119 0000 VarioKeystone® dummy cover Pure white RAL 9010 (50 pieces) LKD 9A46 0034 0000 VarioKeystone® Dust protective plug Pure white RAL 9010 (50 pieces) LKD 9A46 0073 0000 VarioKeystone® dummy cover Jet black RAL 9005 (50 pieces) LKD 9A46 0083 0000 VarioKeystone® Dust protective plug Jet black RAL 9005 (50 pieces) LKD 9A46 0084 0000 LKD 9A46 0036 0000 VarioKeystone® Measuring cable set Tera – Tera Description VarioKeystone® Measuring cable set RJ45 – RJ45 Description VarioKeystone® Measuring cable set Tera – Crossconnect Description ■■ Tera – Tera ■■ RJ45 ■■ Tera – Crossconnect ■■ Length 2 x 3 m ■■ Length 2 x 3 m ■■ Length 2 x 3 m Designation Order no. Designation Order no. Designation Order no. VarioKeystone® Measuring cable set Tera – Tera (2 pieces) LKD 9A04 0166 0000 VarioKeystone® Measuring cable set RJ45 – RJ45 (2 pieces) LKD 9AW3 0020 0000 VarioKeystone® Measuring cable set LKD 9AW3 Tera – Tera (1 piece) 0023 0000 Tera – Crossconnect (1 piece) www.leoni-infrastructure-datacom.com Office Industry DataCenter 91 VarioKeystone® Cu connectivity Cable assembly tools VarioKeystone® UTP/FTP/foil stripping tool VarioKeystone® Parallel pliers Designation VarioKeystone® Parallel pliers (1 piece) Order no. Designation Designation Order no. LKD 9AW1 6007 0000 VarioKeystone® UTP/FTP/foil stripping tool LKD 9AW1 6008 0000 (1 piece) MegaLine® Stripper (1 piece) LKD 9AW1 6043 0000 VarioKeystone® Copper tape VarioKeystone® Assembly set 1/2 VarioKeystone® Release tool Description ■■ Order no. MegaLine® Stripper Description Release tool, 2-part ■■ Description (100 of each) Length 33 m ■■ Set 1: Shrink-fit tube, silver wire, copper foil ■■ Designation VarioKeystone® Release tool (1 piece) Order no. Designation LKD 9AW1 6039 0000 VarioKeystone® Copper tape (length 33 m) www.leoni-infrastructure-datacom.com Set 2: Shrink-fit tube, silver wire Order no. Designation Order no. LKD 9AW1 6011 0000 VarioKeystone® Assembly set 1 LKD 9AW1 6020 0000 VarioKeystone® Assembly set 2 LKD 9AW1 6023 0000 92 MegaLine® Connect45 Cu connectivity www.leoni-infrastructure-datacom.com Office Industry DataCenter MegaLine® Connect45 Cu connectivity 92 MegaLine® Connect45 Connectivity can be so easy 94 MegaLine® Connect45 LEO (Light Emitting Outlet) the "pathfinder feature" 95 MegaLine® Connect45 System overview 96 o dc MegaLine® Connect45 cable plugs • For AWG 24–22 • For AWG 27–26 98 o dc MegaLine® Connect45 jack modules in VarioKeystone® format • Cat. 6A ISO/IEC • Cat. 6A EIA/TIA • LEO Cat. 6A ISO/IEC • LEO Cat. 6A EIA/TIA 99 o dc MegaLine® Connect45 jack modules in keystone format • Cat. 6A ISO/IEC • Cat. 6A EIA/TIA • LEO Cat. 6A ISO/IEC • LEO Cat. 6A EIA/TIA 100 o dc MegaLine® Connect45 patch panel 19"/1 RU • HD 48 Cat. 6A • Unequipped 101 o dc MegaLine® Connect45 wall outlets • Keystone 50 x 50 • Keystone 45 x 45 102 o dc Accessories & tools (MegaLine® Connect45) • LEO detector • Dust protective cap • Mounting tool • Entriegelungswerkzeug 103 o Office dc i DataCenter Industry www.leoni-infrastructure-datacom.com MegaLine® Connect45 93 94 MegaLine® Connect45 Connectivity can be so easy The shortest possible installation times and an uncompromising Pre‑assembled trunks help to keep the necessary assembly approach to electrical performance are the key features times to a minimum. of a future-proof cabling system. With this in mind, LEONI has developed a new copper connection The release tool is a handy solution for opening modules. system, MegaLine® Connect45. The innovative modular system In this way, the existing cabling system can be fitted with unites ultimate performance with maximum ease of assembly. a new module – e.g. with LEO function – in next to no time The basic version, consisting of a Category 7/7A data cable and "with a click". cable connector is completed by simply attaching the required jack module. You can choose from RJ45 jack modules in Category Minimum assembly times – maximum performance. 6A (IEC 60603-7-51) and Category 6A (EIA/TIA 568-C.2). The distances to be covered with cables in DataCenters are often less than 15 metres. The standards refer to these connections Easy assembly – the wires are pressed together and precision- as "short links" and, because not all products are of the same cut in a single step. quality, it is necessary to separate the wheat from the chaff when The shortest possible assembly times are achieved by combining assessing them. The MegaLine® Connect45 system can be used the attachment of the cable plug with the cutting of the wires to implement extremely short link lengths from one metre to size. Easy assembly is particularly useful in DataCenters where upwards. The requirements of the EA permanent link class are installation work must be carried out with zero downtime. easily exceeded. Easy assembly – the wires are pressed together and cut to size in a single step. www.leoni-infrastructure-datacom.com Office Industry DataCenter 95 LEO (Light Emitting Outlet) MegaLine® Connect45 The "pathfinder feature" Jack modules are equipped with the LEO function on an optional basis (LEO = Light Emitting Outlet). A signal transmitter connected to one side of an installed link can be used as a convenient way to identify the corresponding opposite connection by means of a red LED indicator in the jack module. This feature is particularly useful in environments with a high packing density, enabling the corresponding modules to be located quickly and reliably. The LEO detector (on the right in the photo) is used to feed the light signal into the link so that the red LED on the corresponding jack module on the other side lights up. www.leoni-infrastructure-datacom.com 96 MegaLine® Connect45 System overview All components are coordinated for optimum performance: ■■ Quick & easy installation ■■ Maximum performance ■■ Assured functionality for the entire service life Pre-assembled cable MegaLine® G12-150 S/F MegaLine® F10-130 S/F MegaLine® F10-115 S/F MegaLine® F6-90 S/F MegaLine® E5-70 F/F MegaLine® E5-60 U/F MegaLine® Connect45 Cable plug AWG 27–26 MegaLine® Connect45 Cable plug AWG 24–22 Cables & cable plugs www.leoni-infrastructure-datacom.com Office Industry DataCenter MegaLine® Connect45 97 VarioLine® UF underfloor systems Floorbox solutions Jack modules with LEO function Keystone/VarioKeystone® format Cat. 6A (ISO/IEC)/Cat. 6A (EIA/TIA) Wall outlets for MegaLine® Connect45 jack modules Wall outlets Jack modules Keystone/VarioKeystone® format Cat. 6A (ISO/IEC)/Cat. 6A (EIA/TIA) VarioLine® CP6-B consolidation point housing Housings Jack modules MegaLine® Connect45 panel high-density Cat. 6A 48 ports High-density panels www.leoni-infrastructure-datacom.com Patch panel 19" MegaLine® Connect45 panel high-density Cat. 6A 48 ports 98 MegaLine® Connect45 cable plugs AWG 24–22/AWG 27–26 Fig. 1 Cable plug AWG 24–22 Fig. 2 Cable plug AWG 27–26 MegaLine® Connect45 cable plug AWG 24–22 MegaLine® Connect45 cable plug AWG 27–26 Description Accessories The MegaLine® Connect45 cable plug has a cutting-clamping MegaLine® Connect45 dust protective cap connector and is pressed directly onto the installation cable. Once attached, the cable plug can be protected from environmental It is the interface to the individually interchangeable MegaLine® influences by means of the dust protective cap. see page 103 Connect45 jack module. This means that generic transmission links far exceeding the requirements for Class EA can be achieved, depending on the relevant jack module. The jack module can also be changed later without any additional installation effort. ■■ Easy and quick assembly Construction Material Plastic Wiring 4 pairs via IDC contacts acc. to EIA/TIA 568A/B Wire type AWG 24–22 solid and flex or AWG 27–26 solid and flex Fig. Article Wire type Colour Order no. 1 MegaLine® Connect45 cable plug AWG 24–22 (25 pieces) AWG 24–22 solid and flex ● Yellow plastic LKD 9A50 4010 0000 2 MegaLine® Connect45 cable plug AWG 27–26 (25 pieces) AWG 27–26 solid and flex ● Transparent plastic LKD 9A50 4011 0000 www.leoni-infrastructure-datacom.com Office DataCenter Industry 99 MegaLine® Connect45 jack modules in VarioKeystone® format Jack module Cat. 6A with LEO function opal white Fig. 2 Jack module Cat. 6A white Fig. 1 Jack module Cat. 6A aqua MegaLine® Connect45 BM ISO/IEC MegaLine® Connect45 BM EIA/TIA MegaLine® Connect45 LEO BM ISO/IEC MegaLine® Connect45 LEO BM EIA/TIA Description Description For transmitting analogue and digital voice, image and data For transmitting analogue and digital voice, image and data signals. The performance corresponds to Cat. 6A (ISO/IEC) or Cat. signals. The performance corresponds to Cat. 6A (ISO/IEC) or Cat. 6A (EIA/TIA) up to 500 MHz. The requirements of the Class EA 6A (EIA/TIA) up to 500 MHz. The requirements of the Class EA channel and permanent link according to ISO/IEC 11801 Amd. channel and permanent link according to ISO/IEC 11801 Amd. 1/2 are met above 1 m (Cat. 6A) or 10 m (Cat. 6A) respectively. 1/2 are met above 1 m (Cat. 6A) or 10 m (Cat. 6A) respectively. The lengths relate to the 2-connector model. The lengths relate to the 2-connector model. Construction Construction Material Full metal; die-cast zinc, nickel-plated Material Full metal; die-cast zinc, nickel-plated Wiring 4 pairs via cable plug Wiring 4 pairs via cable plug Connection RJ45 jack, with integrated dust flap Connection RJ45 jack, with integrated dust protective compatible with VarioKeystone® Standards flap compatible with VarioKeystone® Standards ■■ ISO/IEC 11801 ■■ EN 50173-1 ■■ IEC 60603-7-51/EIA/TIA 568-C.2 ■■ ISO/IEC 11801  n  EN 50173-1  n  IEC 60603-7-51/EIA/TIA 568-C.2 LEO function LEO = Patch panels with LEO function Light Emitting Outlet permit easy link identification during installation Light detection ≤ 200 m Signal feed Via the LEO detector Description see page 95 Fig. Article 1 MegaLine® Connect45 BM ISO/IEC 2 MegaLine® Connect45 BM EIA/TIA www.leoni-infrastructure-datacom.com Colour Order no. Article Colour Order no. aqua LKD 9A50 2010 0000 MegaLine® Connect45 LEO BM ISO/IEC aqua opal LKD 9A50 2011 0000 white LKD 9A50 2020 0000 MegaLine® Connect45 LEO BM EIA/TIA white opal LKD 9A50 2021 0000 MegaLine® Connect45 Category 6A/6A 100 MegaLine® Connect45 jack modules in keystone format Category 6A/6A Jack module Cat. 6A with LEO function opal white Fig. 2 Jack module Cat. 6A white Fig. 1 Jack module Cat. 6A aqua MegaLine® Connect45 BM Keystone ISO/IEC MegaLine® Connect45 BM Keystone EIA/TIA MegaLine® Connect45 LEO BM Keystone ISO/IEC MegaLine® Connect45 LEO BM Keystone EIA/TIA Description Description For transmitting analogue and digital voice, image and data For transmitting analogue and digital voice, image and data signals. The performance corresponds to Cat. 6A (ISO/IEC) or Cat. signals. The performance corresponds to Cat. 6A (ISO/IEC) or Cat. 6A (EIA/TIA) up to 500 MHz. The requirements of the Class EA 6A (EIA/TIA) up to 500 MHz. The requirements of the Class EA channel and permanent link according to ISO/IEC 11801 Amd. channel and permanent link according to ISO/IEC 11801 Amd. 1/2 are met above 1 m (Cat. 6A) or 10 m (Cat. 6A) respectively. 1/2 are met above 1 m (Cat. 6A) or 10 m (Cat. 6A) respectively. The lengths relate to the 2-connector model. The lengths relate to the 2-connector model. Construction Construction Material Full metal; die-cast zinc, nickel-plated Material Full metal; die-cast zinc, nickel-plated Wiring 4 pairs via cable plug Wiring 4 pairs via cable plug Connection Keystone RJ45 jack, with integrated Connection Keystone RJ45 jack, with integrated dust protective flap dust protective flap Standards Standards ■■ ISO/IEC 11801 ■■ EN 50173-1 ■■ IEC 60603-7-51/EIA/TIA 568-C.2 ■■ ISO/IEC 11801  n  EN 50173-1  n  IEC 60603-7-51/EIA/TIA 568-C.2 LEO function LEO = Patch panels with LEO function Light Emitting Outlet permit easy link identification during installation Light detection ≤ 200 m Signal feed Via the LEO detector Description see page 95 Fig. Article 1 MegaLine® Connect45 BM Keystone ISO/IEC 2 MegaLine® Connect45 BM Keystone EIA/TIA Colour Order no. Article Colour Order no. aqua LKD 9A50 1010 0000 MegaLine® Connect45 LEO BM Keystone ISO/IEC aqua opal LKD 9A50 1011 0000 white LKD 9A50 1020 0000 MegaLine® Connect45 LEO BM Keystone EIA/TIA white opal LKD 9A50 1021 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 101 MegaLine® Connect45 patch panels 19"/1 RU MegaLine® Connect45 Equipped/unequipped MegaLine® Connect45 patch panel HD 48 Cat. 6A MegaLine® Connect45 patch panel 19" Description Description For transmitting analogue and digital voice, image and data The patch panel can be equipped with up to 24 jack modules signals. The performance corresponds to Cat. 6A (ISO/IEC) in keystone format. up to 500 MHz. The requirements of the Class EA channel and permanent link according to ISO/IEC 11801 Amd. 1/2 are met Construction above 1 m (Cat. 6A). The lengths relate to the 2-connector model. Housing Full metal Colour Light grey RAL 7035/Black RAL 9005 Capacity Up to 24 jack modules Strain relief Via cable ties Earthing Via screw on the rear of the panel ■■ High packing density at a single level ■■ Pre-assembled jack modules reduce the installation effort significantly Over the entire width of the cable Construction Cable entry management rail Housing Full metal Colour Light grey RAL 7035/Black RAL 9005 Dimensions Capacity 48 jack modules Cat. 6A (ISO/IEC) 19"/1 RU, 110 mm installation depth Strain relief Via cable ties Earthing Via screw on the rear of the panel Over the entire width of the cable Cable entry management rail Note Patch panels for jack modules in VarioKeystone® format can be found on page 84 Dimensions 19"/1 RU, 121 mm installation depth Standards ■■ ISO/IEC 11801  n   EN 50173-1  n   IEC 60603-7-51 Article Colour Order no. MegaLine® Connect45 patch panel HD 48 Cat. 6A (ISO/IEC) ● Light grey RAL 7035 LKD 9A50 3214 0000 ● Jet black RAL 9005 LKD 9A50 3215 0000 www.leoni-infrastructure-datacom.com Article Colour Order no. MegaLine® Connect45 patch panel 19" ● Light grey RAL 7035 LKD 9A50 1200 0000 ● Jet black RAL 9005 LKD 9A50 1201 0000 102 MegaLine® Connect45 wall outlets for keystone jack modules Fig. 3 Wall outlet 50 x 50/triple gang Fig. 1 Wall outlet 50 x 50/single gang Fig. 4 Wall outlet 45 x 45/single gang Fig. 2 Wall outlet 50 x 50/ double gang MegaLine® Connect45 wall outlet keystone 50 x 50 Fig. 5 Wall outlet 45 x 45/double gang MegaLine® Connect45 wall outlet keystone 45 x 45   French style   German style Wall outlets for equipping with MegaLine® Connect45 jack Wall outlets for equipping with MegaLine® Connect45 jack modules in keystone format. modules in keystone format. Construction Construction Housing body Full metal; die-cast zinc, nickel-plated Housing body Plastic Colours Pure white RAL 9010 Colours Pure white RAL 9010 Labelling Via labelling field Labelling Via labelling field Dimensions Dimensions 50 mm x 50 mm x 30 mm (H x W x D), 45 mm x 45 mm x 42 mm (H x W x D), downward inclination of 30° downward inclination of 30° Note Wall outlets in VarioKeystone® format can be found on page 89 Fig. 1 2 3 – – Designation Order no. Fig. Designation Order no. MegaLine® Connect45 wall outlet keystone 50 x 50/single gang LKD 9A50 1100 0000 4 MegaLine® Connect45 wall outlet keystone 45 x 45/single gang LKD 9A50 1104 0000 MegaLine® Connect45 wall outlet keystone 50 x 50/double gang LKD 9A50 1101 0000 5 MegaLine® Connect45 wall outlet keystone 45 x 45/double gang LKD 9A50 1103 0000 MegaLine® Connect45 wall outlet keystone 50 x 50/triple gang LKD 9A50 1102 0000 – VarioLine® cover frame 45 x 45 (8 pieces) LKD 9ZE8 0013 0000 40 mm surface-mounted housing LKD 9A46 0086 0000 Spacer frame for single-gang surface-mounted housing, 10 mm LKD 9A46 0088 0000 www.leoni-infrastructure-datacom.com Office DataCenter Industry 103 Accessories & tools The cable assembled with the Connect45 cable plug is simply inserted into the dust protective cap and locked MegaLine® Connect45 LEO detector MegaLine® Connect45 dust protective cap Accessories Accessories Detector for feeding in the voltage when using a Connect45 jack For the safe and convenient protection of pre-assembled trunk module with LEO function. cables equipped with MegaLine® Connect45 cable plugs. Housing Full metal Contact RJ45 plug Power supply 4 x LR41 batteries (included) Article Order no. Article Order no. MegaLine® Connect45 LEO detector LKD 9A50 4002 0000 MegaLine® Connect45 dust protective cap (25 pieces) LKD 9A50 4003 0000 MegaLine® Connect45 mounting tool MegaLine® Connect45 release tool Accessories Accessories It takes just a single step to press the contacts of the cable plug For quick and easy opening of the MegaLine® Connect45 jack together and remove the excess wires. module. Article Order no. Article Order no. MegaLine® Connect45 mounting tool LKD 9A50 4001 0000 MegaLine® Connect45 release tool LKD 9A50 4000 0000 www.leoni-infrastructure-datacom.com MegaLine® Connect45 for MegaLine® Connect45 104 104 ELine 1200® EC7 Cu connectivity www.leoni-infrastructure-datacom.com Office Industry DataCenter ELine 1200® EC7 Cu connectivity 104 ELine 1200® EC7 Cu connectivity The passive cabling system for multimedia applications 106 ELine 1200® EC7 System overview 108 o dc EC7 jack and accessories • EC7 jack • EC7 dust protective plug 1 p • EC7 mounting tool o dc Wall outlet insert 50 x 50 111 o dc EC7 patch panel Telephone patch panel 112 o dc EC7 accessories Telephone termination plug 112 o dc EC7 patch panel 19" • 1 RU with 24 ports • 1 RU with 48 ports • 1 RU with 24 ports, angled 113 o dc EC7 mini patch panel With 6 ports 114 o dc EC7 mounting tool For ELine 1200® EC7 jacks 114 o dc EC7 measuring equipment • EC7 measuring adapter (for Fluke DTX 1800) • EC7-EC7 plug 115 o Office dc i DataCenter Industry www.leoni-infrastructure-datacom.com 110 ELine 1200® EC7 Cu connectivity 105 106 ELine 1200® EC7 Cu connectivity The passive cabling system for multimedia applications Multimedia in a systematic way Connection options Multimedia up to 1.5 GHz via twisted pair The chamber system of the ELine 1200® EC7 connector is based on the principle of paired shielding of the 100 Ω data cables used in the MegaLine® series. The cable and connector form a perfect combination of four pairs and four chambers with GHz performance. The signal paths are separate throughout, which opens up a wide range of possible uses: A passive cabling system for multimedia applications – is that even possible? After all, it is a term that is more ■■ often used in connection with consumer electronics. Cable sharing: Simultaneous use of two data services from Class A to F with just one cable and one EC7 jack ELine 1200® EC7 supports multimedia by allowing different media to be used in parallel via a structured cabling system: ■■ Service sharing: Simultaneous operation of different services (e.g. telephone/ data) in parallel - without the risk of NEXT problems Data/voice/images/TV signals – in one connection. This unique copper connectivity from LEONI delivers The devices are connected using appropriately matched ELine a sophisticated system solution, the only one of its kind, geared 1200® EC7 connection cable in one, two or four pairs. towards the needs of the market. ELine 1200® EC7 delivers multimedia directly to the desktop as a four-lane data highway. www.leoni-infrastructure-datacom.com Office Industry DataCenter 2 data services from Class A to F Mixed telephone and data services Cable sharing Service sharing Telephone/fax PC PC PC Telephone TV via twisted pair "High tech" and "added value" have their price Transmitting analogue and digital CATV services via twisted The ELine 1200® EC7 system is no more expensive than pair is extremely challenging from a technical point of view. conventional systems overall, because separate cables Transmission frequencies of up to 862 MHz are required or connectors are not needed for each service. This allows for transmitting all channels, which requires a system with savings of up to 50 % of the necessary cables, connectors, extremely high ­performance reserves and, in particular, good wall outlets and patch panels. attenuation characteristics. Multiple use also reduces the system costs (depending on the ELine 1200® EC7 is specifically optimised for this application services used) by 15 – 30 %. The reduction in the number and the extensive product range provides all the tools needed of cables and wall outlets actually required usually also allows to transmit CATV signals. The twisted pair infrastructure reductions in the costs for cable ducts or switching cabinets. (100 Ω) is connected to the TV infrastructure (75 Ω) via passive connection cables with integrated balun. "Service sharing" with ELine 1200® EC7 means saving costs. In contrast to previous solutions, the outlets are completely flexible. The system solution is already successfully in use worldwide, For example, a telephone or data outlet can become a TV which means that we can refer to a wide installed base with connection at any time. testimonials from well-known customers. www.leoni-infrastructure-datacom.com ELine 1200® EC7 Cu connectivity 107 108 ELine 1200® EC7 Cu connectivity System overview ELine 1200® EC7 jack ■■ VarioLine® modular system peripherals Modular jack for multimedia applications Consolidation points – CP Underfloor range – UF ELine 1200® EC7 wall outlets ■■ Double-gang wall outlet for up to two modular jacks MegaLine® Patch ■■ Triple-gang wall outlet for up to three modular jacks ■■ Patch cord ■■ Trunk cable ELine 1200® EC7 panels ■■ Panel with 24 ports (standard version) ■■ 48-port panel with double packing density at a single level Pre-assembled cable MegaLine® G12-150 S/F ELine 1200® EC7 Cable Jack module www.leoni-infrastructure-datacom.com Office Industry DataCenter ELine 1200® EC7 Cu connectivity 109 ELine 1200® EC7 patch panel 1 RU/48 ports can be equipped with ELine 1200® EC7 jacks ELine 1200® EC7 patch panel 1 RU/24 ports can be equipped with ELine 1200® EC7 jacks VarioLine® housing CP6/CP12/CP24 Consolidation point housing for 6, 12 or 24-port module panel Housings VarioLine® UF underfloor systems Floorbox solutions ELine 1200® EC7 Cu wall outlet insert 50 x 50 double gang/triple gang Wall outlets www.leoni-infrastructure-datacom.com 110 ELine 1200® EC7 jack and accessories Multimedia up to 1.5 GHz via twisted pair ELine 1200® EC7 jack Application Compatibility For fast installation in patch panels, floorbox solutions and wall VarioLine® CP Consolidation point range (from page 237) outlet inserts. VarioLine® UF Underfloor systems/floorbox solutions (from page 253) Construction Jack Die-cast zinc, nickel-plated Accessories Contacts Gold-plated ELine 1200® EC7 dust protective plug 1 p ELine 1200® EC7 mounting tool (description see page 140) Insulation displace- Bronze, tinned ment contacts Dimensions Jack 14 mm x 16 mm x 36.9 mm (W x H x D) Installation depth 40 mm ELine 1200® EC7 dust protective plug 1 p Article Order no. ELine 1200® EC7 jack (8 pieces) LKD 9ZE4 4444 0000 ELine 1200® EC7 dust protective plug 1 p (1 piece) LKD 9ZE3 0066 0000 ELine 1200® EC7 mounting tool (1 piece) LKD 9ZE3 0007 0000 ELine 1200® EC7 mounting tool www.leoni-infrastructure-datacom.com Office Industry DataCenter 111 ELine 1200® Wall outlet insert Fig. 1 Cu wall outlet insert 50 x 50/ double gang, can be equipped with 2 ELine 1200® EC7 jacks Fig. 2 Cu wall outlet insert 50 x 50/ triple gang, can be equipped with 3 ELine 1200® EC7 jacks ELine 1200® EC7 Cu wall outlet insert 50 x 50 Description Accessories (optional) Unequipped wall outlet insert with dust protective cover, for VarioKeystone® cover frame installation in commercially available 50 x 50 mm cover frames. Order no.: LKD 9A41 0003 0000 Housing ■■ Plastic cover frame 80 x 80 mm Cut-out 50 x 50 mm, square Housing body Plastic ■■ Colour Pure white RAL 9010 ■■ Colour: Pure white RAL 9010 Earth connection Via M4 thread ■■ PU: 1 piece Dimensions 50 mm x 50 mm x 30.5 mm (H x W x D empty) Downward inclination 62° Installation depth 25 mm Matching jacks Fig. ELine 1200® EC7 Article Order no. 1 ELine 1200® EC7 Cu wall outlet insert/double gang LKD 9ZE3 0010 0000 (8 pieces) 2 ELine 1200® EC7 Cu wall outlet insert/triple gang (8 pieces) www.leoni-infrastructure-datacom.com LKD 9ZE3 0041 0000 ELine 1200® EC7 Cu connectivity for surface or flush mounting, duct and many underfloor systems 112 ELine 1200® EC7 patch panel ELine 1200® EC7 accessories Telephone Telephone ELine 1200® EC7 telephone patch panel ELine 1200® EC7 termination plug Application Application Telephone patch panel for operating up to 100 telephone As a connectable termination in ISDN So bus-networks ELine services at a single level (100 DA). 1200® EC7. Connections Construction ■■ Complete with 25 x (1 x 4) double-core jacks ■■ EC7 resistor/termination plug ■■ 25 x 8 LSA connectivity on the rear ■■ 2p ■■ IDC terminal connections on 5 x 5 basic modules ■■ With 2 x 100 Ω terminating resistors Dimensions Panel 485 mm x 44 mm x 106 mm (W x H x D) Installation depth 104 mm Article Order no. Article Order no. ELine 1200® EC7 telephone patch panel (1 piece) LKD 9ZE1 0221 0000 ELine 1200® EC7 termination plug (1 piece) LKD 9ZE1 0104 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 113 ELine 1200® EC7 patch panel 19" Fig. 1 patch panel with 48 ports, can be equipped with ELine 1200® EC7 jacks Fig. 2 patch panel with 24 ports, can be equipped with ELine 1200® EC7 jacks ELine 1200® EC7 patch panel 1 RU/24 ports ELine 1200® EC7 patch panel 1 RU/24 ports, angled ELine 1200® EC7 patch panel 1 RU/48 ports Description Description Patch panel 19", unequipped, for holding up to 24 or 48 ELine Patch panel 19" , unequipped, for holding up to 24 ELine 1200® 1200® EC7 jacks (including a mixture). EC7 jacks (including a mixture). ■■ Snap-in assembly ■■ Snap-in assembly ■■ Strain relief ■■ Strain relief ■■ Earth connection ■■ Earth connection Housing Housing Housing Steel panel Colour of front panel Light grey RAL 7035 or Jet black RAL 9005 Housing Steel panel Labelling 1 – 24 (screen printing) Colour of front panel Jet black RAL 9005 Dimensions 19"/1 RU 44 mm x 483 mm x 98 mm (H x W x D) Dimensions 19"/1 RU Fig. 44 mm x 483 mm x 175 mm (H x W x D) Article Colour Order no. Article Colour Order no. 1 ELine 1200® EC7 patch panel 1 RU/48 ports (1 piece) Light grey RAL 7035 LKD 9ZE3 0052 0000 Jet black RAL 9005 LKD 9ZE3 0047 0000 ELine 1200® EC7 patch panel 1 RU/24 ports, angled (1 piece) Jet black RAL 9005 LKD 9ZE3 0061 0000 2 ELine 1200® EC7 patch panel 1 RU/24 ports (1 piece) Light grey RAL 7035 LKD 9ZE3 0002 0000 Jet black RAL 9005 LKD 9ZE3 0046 0000 www.leoni-infrastructure-datacom.com ELine 1200® EC7 Cu connectivity 1 RU, with 24/48 ports 114 ELine 1200® EC7 mini patch panel ELine 1200® EC7 mounting tool with 6 ports for ELine 1200® EC7 jacks ELine 1200® EC7 mini patch panel with 6 ports ELine 1200® EC7 mounting tool Description Description Mini patch panel, unequipped, for holding up to 6 ELine 1200® For easy and secure connection of the ELine 1200® EC7 jacks. EC7 jacks. ■■ Snap-in assembly ■■ For mounting in a wall, floor, ceiling, furniture, DIN rails ■■ Suitable for industrial environments Housing Housing Closed, steel panel Colour Pure white RAL 9010 Dimensions 35 mm x 122 mm x 100 mm (H x W x D) Article Colour Order no. Article Order no. ELine 1200® EC7 mini patch panel with 6 ports (1 piece) Pure white RAL 9010 LKD 9ZE3 0045 0000 ELine 1200® EC7 mounting tool (1 piece) LKD 9ZE3 0007 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 115 ELine 1200® EC7 measuring adapter (for Fluke DTX 1800) ELine 1200® EC7 Cu connectivity ELine 1200® EC7 measuring equipment ELine 1200® EC7-EC7 plug Application Application Measuring adapter for testing EC7 cabling systems up to Class F Replaceable measuring probe for Class F measurements EC7 for (600 MHz), permanent link and channel. permanent link and channel measuring adapter Fluke DTX 1800. The measuring probe consists of an EC7-EC7 plug that can Construction be replaced in case of wear. Mating face Both sides EC7, 4 pairs Article Order no. Article Order no. ELine 1200® EC7 measuring adapter (for Fluke DTX 1800) (1 pair) LKD 9ZE3 0038 0000 ELine 1200® EC7-EC7 plug (1 piece) LKD 9ZE3 0043 0000 www.leoni-infrastructure-datacom.com 116 116 MegaLine Cu patch cords / trunk cables ® www.leoni-infrastructure-datacom.com Office Industry DataCenter MegaLine® Cu patch cords / trunk cables 117 o dc Patch cord RJ45/RJ45 Cat. 5/100 MHz 118 o dc Patch cord RJ45/RJ45 Cat. 6/250 MHz 119 o dc Patch cord RJ45/RJ45 Cat. 6/500 MHz 120 o dc Patch cord RJ45/RJ45 Cat. 6A/500 MHz 121 i LED patch cord RJ45/RJ45 Cat. 6/500 MHz with LED signal in the plug 122 i Industrial patch cord RJ45/RJ45 Cat. 5/100 MHz 123 i Industrial patch cord with Han® 3A plugs • Han 3A RJ45/RJ45 • Han 3A RJ45/IP20 RJ45 124 i Industrial patch cord RJ45/RJ45 Cat. 6/500 MHz 125 o dc Patch cord TERA 126 TM o dc Patch cord and connection cable EC7 • 4 p EC7/EC7 • 4 p EC7/RJ45 • 4 p EC7/open o dc Patch cord and connection cable EC7 • 2 p EC7/EC7 • 2 p EC7/open • 2 p EC7/RJ45 • 2 p EC7/RJ45 Cross over 129 o dc Patch cord and connection cable EC7 • 1 p EC7/EC7 • 1 p EC7/open • 1 p EC7/RJ10 • 1 p EC7/RJ11 130 o dc Patch cord and connection cable EC7 • 1 p EC7/RJ45 • 2 p EC7/RJ45 131 i VarioKeystone® trunk cable, industrial • Trunk cable • Crossconnect trunk cable 132 o dc VarioKeystone® trunk cable • Trunk cable • Crossconnect trunk cable 133 o dc i RJ45 trunk cable, 8 port • Trunk RJ45 plug/RJ45 plug 134 o dc i VarioKeystone® trunk cable, 4 port/8 port o dc MegaLine® Connect45 trunk cable • Cat. 6A modules • Cat. 6A modules 136 o dc MegaLine® Connect45 trunk cable, 8 port • Cat. 6A modules 137 o dc MegaLine® Connect45 CP cable • Cat. 6A/Cat. 6A 138 o dc MegaLine® Connect45 CP cable • Cat. 7, Class F 139 o dc Accessories for LED patch cords • LED colour clip • LED detector 140 o dc Accessories for patch cords • RJ45 colour coding clip 140 o dc Test report For all trunk cables 141 o Office cable dc i DataCenter cables Industrial cables www.leoni-infrastructure-datacom.com 128 135 MegaLine® Cu patch cords / trunk cables 117 118 MegaLine® Patch cord RJ45/RJ45 Cat. 5/100 MHz Shielded, Cat. 5, Class D, with coloured moulded boots MegaLine® Patch 5D-RJ45 Description Construction The cable type used is suitable for transmission rates EMC Foil overall shielding of up to 100 MHz. The pair shielding and the high-coverage RJ45 plug EN 60603-7 copper braiding as overall shielding ensure excellent NEXT Electrical values Cat. 5, Class D and impedance values. Assignment 1:1 Standards ISO/IEC 11801/EN 50173 The patch cords and connection cables are equipped with a shielded RJ45 plug and moulded boots at both ends. Fire behaviour Flame retardance IEC 60332-1-2 Applications IEEE 802.3, 10Base-T, 100Base-T, 1000Base-T, IEEE 802.5 16MB, Accessories ISDN, FDDI, ATM MegaLine® Patch RJ45 colour coding clip Description see page 140 In different colours for visual coding of the patch cords Length Article Order no. Grey (PVC) Blue (PVC) Green (PVC) Yellow (PVC) Red (PVC) 0.5 LKD 9A01 0400 0000 LKD 9A01 0410 0000 LKD 9A01 0420 0000 LKD 9A01 0430 0000 LKD 9A01 0440 0000 1.0 LKD 9A01 0401 0000 LKD 9A01 0411 0000 LKD 9A01 0421 0000 LKD 9A01 0431 0000 LKD 9A01 0441 0000 1.5 LKD 9A01 0402 0000 LKD 9A01 0412 0000 LKD 9A01 0422 0000 LKD 9A01 0432 0000 LKD 9A01 0442 0000 2.0 LKD 9A01 0403 0000 LKD 9A01 0413 0000 LKD 9A01 0423 0000 LKD 9A01 0433 0000 LKD 9A01 0443 0000 m 2.5 3.0 MegaLine® Patch 5D-RJ45 LKD 9A01 0404 0000 LKD 9A01 0414 0000 LKD 9A01 0424 0000 LKD 9A01 0434 0000 LKD 9A01 0444 0000 LKD 9A01 0405 0000 LKD 9A01 0415 0000 LKD 9A01 0425 0000 LKD 9A01 0435 0000 LKD 9A01 0445 0000 4.0 LKD 9A01 0406 0000 LKD 9A01 0416 0000 LKD 9A01 0426 0000 LKD 9A01 0436 0000 LKD 9A01 0446 0000 5.0 LKD 9A01 0407 0000 LKD 9A01 0417 0000 LKD 9A01 0427 0000 LKD 9A01 0437 0000 LKD 9A01 0447 0000 7.5 LKD 9A01 0408 0000 LKD 9A01 0418 0000 LKD 9A01 0428 0000 LKD 9A01 0438 0000 LKD 9A01 0448 0000 10.0 LKD 9A01 0409 0000 LKD 9A01 0419 0000 LKD 9A01 0429 0000 LKD 9A01 0439 0000 LKD 9A01 0449 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 119 MegaLine® Patch cord RJ45/RJ45 Cat. 6/250 MHz MegaLine® Cu patch cords / trunk cables Unshielded, Cat. 6, Class E, with grey moulded boots MegaLine® Patch 6E-RJ45U Description Construction The cable type used is suitable for transmission rates RJ45 plug EN 60603-7 of up to 250 MHz. The patch cord offers excellent NEXT Electrical values Cat. 6, Class E and return loss values thanks to its construction. Assignment 1:1 Standards ISO/IEC 11801/EN 50173 The patch cords and connection cables are equipped with an unshielded RJ45 plug and moulded boots at both ends. Fire behaviour Smoke density IEC 61034 Applications Halogen free IEC 60754-2 IEEE 802.3, 10Base-T, 100Base-T, 1000Base-T, IEEE 802.5 16MB, Flame retardance IEC 60332-1-2 ISDN, FDDI, ATM Accessories Description see page 140 MegaLine® Patch RJ45 colour coding clip In different colours for visual coding of the patch cords Length Article Order no. Grey (LSOH) m 0.5 LKD 9A05 0027 0000 1.0 LKD 9A05 0028 0000 1.5 LKD 9A05 0029 0000 2.0 LKD 9A05 0030 0000 2.5 3.0 MegaLine® Patch RJ45U LKD 9A05 0031 0000 LKD 9A05 0032 0000 4.0 LKD 9A05 0033 0000 5.0 LKD 9A05 0034 0000 7.5 LKD 9A05 0035 0000 10.0 LKD 9A05 0036 0000 www.leoni-infrastructure-datacom.com 120 MegaLine® Patch cord RJ45/RJ45 Cat. 6/500 MHz Shielded, Cat. 6, Class EA, with coloured moulded boots MegaLine® Patch 6EA-RJ45 Description Construction The cable type used is suitable for transmission rates EMC Combined shielding (PiMf + braiding) of up to 500 MHz. The pair shielding and the high-coverage RJ45 plug EN 60603-7 copper braiding as overall shielding ensure excellent NEXT Electrical values Cat. 6, Class EA and return loss values. Assignment 1:1 Standards ISO/IEC 11801/EN 50173 The patch cords and connection cables are equipped with a shielded RJ45 plug and moulded boots at both ends. Fire behaviour Smoke density Applications Halogen free IEEE 802.3, 10Base-T, 100Base-T, 1000Base-T, Flame retardance IEC 61034 IEC 60754-2 IEC 60332-1-2 suitable for 10GBase-T, IEEE 802.5 16MB, ISDN, FDDI, ATM Accessories Description see page 140 MegaLine® Patch RJ45 colour coding clip In different colours for visual coding of the patch cords Length Article Order no. Grey (LSOH) Blue (LSOH) Green (LSOH) Yellow (LSOH) Red (LSOH) 0.5 LKD 9A02 1132 0000 LKD 9A02 1152 0000 LKD 9A02 1162 0000 LKD 9A02 1142 0000 LKD 9A02 1172 0000 1.0 LKD 9A02 1133 0000 LKD 9A02 1153 0000 LKD 9A02 1163 0000 LKD 9A02 1143 0000 LKD 9A02 1173 0000 m 1.5 LKD 9A02 1134 0000 LKD 9A02 1154 0000 LKD 9A02 1164 0000 LKD 9A02 1144 0000 LKD 9A02 1174 0000 2.0 LKD 9A02 1135 0000 LKD 9A02 1155 0000 LKD 9A02 1165 0000 LKD 9A02 1145 0000 LKD 9A02 1175 0000 2.5 3.0 MegaLine® Patch 6EA-RJ45 LKD 9A02 1136 0000 LKD 9A02 1156 0000 LKD 9A02 1166 0000 LKD 9A02 1146 0000 LKD 9A02 1176 0000 LKD 9A02 1137 0000 LKD 9A02 1157 0000 LKD 9A02 1167 0000 LKD 9A02 1147 0000 LKD 9A02 1177 0000 4.0 LKD 9A02 1138 0000 LKD 9A02 1158 0000 LKD 9A02 1168 0000 LKD 9A02 1148 0000 LKD 9A02 1178 0000 5.0 LKD 9A02 1139 0000 LKD 9A02 1159 0000 LKD 9A02 1169 0000 LKD 9A02 1149 0000 LKD 9A02 1179 0000 7.5 LKD 9A02 1140 0000 LKD 9A02 1160 0000 LKD 9A02 1170 0000 LKD 9A02 1150 0000 LKD 9A02 1180 0000 10.0 LKD 9A02 1141 0000 LKD 9A02 1161 0000 LKD 9A02 1171 0000 LKD 9A02 1151 0000 LKD 9A02 1181 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 121 MegaLine® Patch cord RJ45/RJ45 Cat. 6A/500 MHz MegaLine® Cu patch cords / trunk cables Shielded, Cat. 6A, Class EA, with coloured moulded boots MegaLine® Patch 6AEA-RJ45 Description Construction The cable type used is suitable for transmission rates EMC Combined shielding (PiMf + braiding) of up to 500 MHz. The pair shielding and the high-coverage RJ45 plug EN 60603-7 copper braiding as overall shielding ensure excellent NEXT Electrical values Cat. 6A, Class EA and return loss values. Assignment 1:1 Standards ISO/IEC 11801/EN 50173 The patch cords and connection cables are equipped with a shielded RJ45 plug and moulded boots at both ends. Fire behaviour Smoke density IEC 61034 Applications Halogen free IEC 60754-2 IEEE 802.3, 10Base-T, 100Base-T, 1000Base-T, Flame retardance IEC 60332-1-2 suitable for 10GBase-T, IEEE 802.5 16MB, ISDN, FDDI, ATM Accessories Description see page 140 MegaLine® Patch RJ45 colour coding clip In different colours for visual coding of the patch cords Length Article Order no. Grey (LSOH) Blue (LSOH) Green (LSOH) Yellow (LSOH) Red (LSOH) 0.5 LKD 9A02 3020 0000 LKD 9A02 3030 0000 LKD 9A02 3040 0000 LKD 9A02 3050 0000 LKD 9A02 3060 0000 1.0 LKD 9A02 3021 0000 LKD 9A02 3031 0000 LKD 9A02 3041 0000 LKD 9A02 3051 0000 LKD 9A02 3061 0000 m 1.5 LKD 9A02 3022 0000 LKD 9A02 3032 0000 LKD 9A02 3042 0000 LKD 9A02 3052 0000 LKD 9A02 3062 0000 2.0 LKD 9A02 3023 0000 LKD 9A02 3033 0000 LKD 9A02 3043 0000 LKD 9A02 3053 0000 LKD 9A02 3063 0000 LKD 9A02 3024 0000 LKD 9A02 3034 0000 LKD 9A02 3044 0000 LKD 9A02 3054 0000 LKD 9A02 3064 0000 LKD 9A02 3025 0000 LKD 9A02 3035 0000 LKD 9A02 3045 0000 LKD 9A02 3055 0000 LKD 9A02 3065 0000 2.5 3.0 MegaLine® Patch 6AEA-RJ45 4.0 LKD 9A02 3026 0000 LKD 9A02 3036 0000 LKD 9A02 3046 0000 LKD 9A02 3056 0000 LKD 9A02 3066 0000 5.0 LKD 9A02 3027 0000 LKD 9A02 3037 0000 LKD 9A02 3047 0000 LKD 9A02 3057 0000 LKD 9A02 3067 0000 7.5 LKD 9A02 3028 0000 LKD 9A02 3038 0000 LKD 9A02 3048 0000 LKD 9A02 3058 0000 LKD 9A02 3068 0000 10.0 LKD 9A02 3029 0000 LKD 9A02 3039 0000 LKD 9A02 3049 0000 LKD 9A02 3059 0000 LKD 9A02 3069 0000 www.leoni-infrastructure-datacom.com 122 MegaLine® LED patch cord RJ45/RJ45 Cat. 6/500 MHz Shielded, Cat. 6, Class EA, with LED light signal in the plug MegaLine® Patch LED 6EA-RJ45 Description Construction Specially for use in offices, industrial plants and DataCenters. Cable type LEONI Megaline® F6-90 S/FTP The plug contains one red LED. The light signal is activated using Outer sheath Halogen-free, flame-retardant compound a detector that is placed on a contact pair on the rear of the plug. Plug RJ45 shielded, IEC 60603-7, grey Strain relief Moulded plug, with separate boot Three different signal types can be selected by repeatedly pressing the detector button: Performance ➔ continuous light/slow flashing/fast flashing Transmission The other end of the LED patch cord then responds with the bandwidth Max. 500 MHz (Class EA) Electrical values Cat. 6 acc. to ISO/IEC 11801, identical light signal and in this way can be clearly identified. EN 50173-x, IEC 60603-7-5 Applications Fire behaviour For use in structured cabling systems according Smoke density to ISO/IEC 11801 and EN 50173-x. Ideal for all applications Halogen free up to Class EA (video, data, telephony) Flame retardance IEC 60754-2 >10 GbE according to IEEE 802.3 an, cable sharing, VoIP, PoE. Fire load IEC 60332-1-2 IEC 61034 0.33 MJ/m (approx.) Length Article Order no. Grey (LSOH) m Blue (LSOH) Aqua (LSOH) Yellow (LSOH) Red (LSOH) Red (LSOH) Crossover 0.5 LKD 9A09 0100 0000 LKD 9A09 0110 0000 LKD 9A09 0140 0000 LKD 9A09 0130 0000 LKD 9A09 0120 0000 LKD 9A09 0160 0000 1.0 LKD 9A09 0101 0000 LKD 9A09 0111 0000 LKD 9A09 0141 0000 LKD 9A09 0131 0000 LKD 9A09 0121 0000 LKD 9A09 0161 0000 1.5 LKD 9A09 0102 0000 LKD 9A09 0112 0000 LKD 9A09 0142 0000 LKD 9A09 0132 0000 LKD 9A09 0122 0000 LKD 9A09 0162 0000 2.0 LKD 9A09 0103 0000 LKD 9A09 0113 0000 LKD 9A09 0143 0000 LKD 9A09 0133 0000 LKD 9A09 0123 0000 LKD 9A09 0163 0000 LKD 9A09 0104 0000 LKD 9A09 0114 0000 LKD 9A09 0144 0000 LKD 9A09 0134 0000 LKD 9A09 0124 0000 LKD 9A09 0164 0000 2.5 3.0 MegaLine® Patch LED 6EA-RJ45 4.0 LKD 9A09 0105 0000 LKD 9A09 0115 0000 LKD 9A09 0145 0000 LKD 9A09 0135 0000 LKD 9A09 0125 0000 LKD 9A09 0165 0000 LKD 9A09 0106 0000 LKD 9A09 0116 0000 LKD 9A09 0146 0000 LKD 9A09 0136 0000 LKD 9A09 0126 0000 LKD 9A09 0166 0000 5.0 LKD 9A09 0107 0000 LKD 9A09 0117 0000 LKD 9A09 0147 0000 LKD 9A09 0137 0000 LKD 9A09 0127 0000 LKD 9A09 0167 0000 7.5 LKD 9A09 0108 0000 LKD 9A09 0118 0000 LKD 9A09 0148 0000 LKD 9A09 0138 0000 LKD 9A09 0128 0000 LKD 9A09 0168 0000 10.0 LKD 9A09 0109 0000 LKD 9A09 0119 0000 LKD 9A09 0149 0000 LKD 9A09 0139 0000 LKD 9A09 0129 0000 LKD 9A09 0169 0000 Other lengths on request www.leoni-infrastructure-datacom.com Office Industry DataCenter 123 MegaLine® Industrial patch cord RJ45/RJ45 Cat. 5/100 MHz MegaLine® Cu patch cords / trunk cables Shielded, Cat. 5, Class D, with yellow moulded boots MegaLine® Patch Industry 5D-RJ45 Description Construction The cable type used is suitable for transmission rates EMC Shielding (braiding) of up to 100 MHz. The pair shielding and the high-coverage RJ45 plug EN 60603-7 copper braiding as overall shielding ensure excellent NEXT Electrical values Cat. 5, Class D and return loss values. Cable/boot Yellow (PUR superflex)/yellow The patch cords and connection cables are equipped with Fire behaviour a shielded RJ45 plug and moulded boots at both ends. Smoke density IEC 61034-1/2 Halogen free IEC 60754-1/2 Flame retardance IEC 60332-2-2 The "superflex" design is ideal for challenging industrial applications (e.g. drag chains). Applications IEEE 802.3, 10Base-T, 100Base-T, 1000Base-T, suitable for 10GBase-T, IEEE 802.5 16MB, ISDN, FDDI, ATM Length Article Order no. Yellow (PUR) m 10.0 LKD 9A07 0084 0000 20.0 30.0 LKD 9A07 0155 0000 MegaLine® Patch Industry 5D-RJ45 LKD 9A07 0082 0000 40.0 LKD 9A07 0179 0000 50.0 LKD 9A07 0085 0000 www.leoni-infrastructure-datacom.com 124 MegaLine® Industrial patch cord with Han® 3A plugs Cat. 6, Class E MegaLine® Patch Han 3A RJ45/RJ45 MegaLine® Patch Han 3A RJ45/IP20 RJ45 Description Description Pre-assembled system cable ready for connection with Pre-assembled system cable ready for connection with Han® 3A RJ45 to Han® 3A RJ45. Han® 3A RJ45 to IP20 RJ45. ■■ Han® 3A interface in metal also offers increased protection ■■ against heat ■■ against heat Mating compatible with many controllers, devices and ■■ automation systems ■■ Han® 3A interface in metal also offers increased protection Mating compatible with many controllers, devices and automation systems With extremely robust RJ45, IP65/IP67 cords Construction ■■ With extremely robust RJ45, IP65/IP67 cords Construction Sheath material PUR, LSZH Sheath material PUR, LSZH Performance Acc. to Cat. 6 or for Class E (250 MHz) Performance Acc. to Cat. 6 or for Class E (250 MHz) Length Article 1.5 m 3.0 m 5.0 m 10.0 m MegaLine® Patch Han 3A RJ45/RJ45 Order no. Length LKD 9A07 0110 0000 1.5 m LKD 9A07 0111 0000 3.0 m LKD 9A07 0112 0000 5.0 m LKD 9A07 0113 0000 10.0 m Article Order no. LKD 9A07 0088 0000 MegaLine® Patch Han 3A RJ45/IP20 RJ45 LKD 9A07 0089 0000 LKD 9A07 0090 0000 LKD 9A07 0091 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 125 MegaLine® Industrial patch cord RJ45/RJ45 Cat. 6/500 MHz MegaLine® Cu patch cords / trunk cables Shielded, Cat. 6, Class EA, with black moulded boots MegaLine® Patch Industry 6EA-RJ45 Description Construction The cable type used is suitable for transmission rates EMC Combined shielding (PiMf + braiding) of up to 500 MHz. The pair shielding and the high-coverage RJ45 plug EN 60603-7 copper braiding as overall shielding ensure excellent NEXT Electrical values Cat. 6, Class EA and return loss values. Cable/boot Yellow (PUR)/black The patch cords and connection cables are equipped with Fire behaviour a shielded RJ45 plug at both ends. Smoke density IEC 61034-1/2 Halogen free IEC 60754-1/2 Flame retardance IEC 60332-2-2 Applications IEEE 802.3, 10Base-T, 100Base-T, 1000Base-T, suitable for 10GBase-T,IEEE 802.5 16MB, ISDN, FDDI, ATM Accessories see page 140 MegaLine® Patch RJ45 colour coding clip In different colours for visual coding of the patch cords Length Article m Order no. Yellow (PUR) 0.5 LKD 9A07 0160 0000 1.0 LKD 9A07 0161 0000 1.5 LKD 9A07 0162 0000 2.0 2.5 LKD 9A07 0163 0000 MegaLine® Patch Industry 6EA-RJ45 LKD 9A07 0164 0000 3.0 LKD 9A07 0165 0000 5.0 LKD 9A07 0166 0000 7.5 LKD 9A07 0167 0000 10.0 LKD 9A07 0168 0000 www.leoni-infrastructure-datacom.com 126 MegaLine® Patch cord TERA™ Shielded, with moulded boots MegaLine® Patch TERA Description Applications Wiring The patch cord and connection cable are equipped with TERA™ n 10BASE-T/100BASE-T2 TERA™ 2-pair to RJ45 or RJ45 plugs as required (the RJ45 plug has a moulded boot). n Token ring TERA™ 2-pair to RJ45 n ISDN TERA™ 2-pair to RJ45 The appropriate cable type for the application is used for n Telephone line TERA™ 1-pair to RJ45 assembly. The cable type F10-120 S/F flex used is designed n Telephone line TERA™ 1-pair to RJ11 for a bandwidth of up to 1,000 Mhz with 4-pair assignment. n User-defined TERA™ 4-pair to RJ45 n 2-pair connecting line TERA™ to TERA™ n 4-pair connecting line TERA™ to TERA™ Applications 10BASE-T/100BASE-T2 Token ring ISDN Telephone line TERA™ 2-pair to RJ45 TERA™ 2-pair to RJ45 TERA™ 2-pair to RJ45 TERA™ 1-pair to RJ45 Patch cord Wiring Length Article m 1.0 2.0 3.0 5.0 MegaLine® Patch TERA™ 2-pair to RJ45* (F10-120 S/F flex) Order no. Article 10BASE-T/100BASE-T2 Token ring ISDN LKD 9A04 0000 0000 LKD 9A04 0006 0000 LKD 9A04 0012 0000 LKD 9A04 0001 0000 LKD 9A04 0007 0000 LKD 9A04 0013 0000 LKD 9A04 0002 0000 LKD 9A04 0008 0000 LKD 9A04 0014 0000 LKD 9A04 0003 0000 LKD 9A04 0009 0000 LKD 9A04 0015 0000 Order no. Telephone line LKD 9A04 0022 0000 MegaLine® Patch TERA™ 1-pair to RJ45* (326 flex) LKD 9A04 0023 0000 LKD 9A04 0024 0000 LKD 9A04 0025 0000 TERA™ is a registered trademark of the Siemon Company www.leoni-infrastructure-datacom.com Office Industry DataCenter MegaLine® Cu patch cords / trunk cables 127 Applications Telephone line Any 2-pair connecting line 4-pair connecting line TERA™ 1-pair to RJ11 TERA™ 4-pair to RJ45 TERA™ to TERA™ TERA™ to TERA™ Patch cord Wiring Length Article m 3.0 5.0 Article Telephone line MegaLine® Patch TERA™ 1-pair to RJ11* (326 flex) LKD 9A04 0018 0000 LKD 9A04 0019 0000 LKD 9A04 0045 0000 TERA™ is a registered trademark of the Siemon Company www.leoni-infrastructure-datacom.com Article User-defined LKD 9A04 0017 0000 1.0 2.0 Order no. LKD 9A04 0039 0000 MegaLine® Patch TERA™ 4-pair to RJ45* (F10-120 S/F flex) LKD 9A04 0040 0000 LKD 9A04 0041 0000 LKD 9A04 0042 0000 MegaLine® Patch TERA™ to TERA™ (F10-120 S/F flex) Order no. 2-pair connecting line 4-pair connecting line LKD 9A04 0026 0000 LKD 9A04 0032 0000 LKD 9A04 0027 0000 LKD 9A04 0033 0000 LKD 9A04 0028 0000 LKD 9A04 0034 0000 LKD 9A04 0029 0000 LKD 9A04 0035 0000 128 MegaLine® Patch cord and connection cable EC7 4-pair, shielded, with yellow boots MegaLine® Patch 4P EC7/EC7 MegaLine® Patch 4P EC7/RJ45 MegaLine® Patch 4P EC7/open Description Construction Patch cord and connection cable for Gigabit Ethernet. Cable type 4 p, Light grey RAL 7035 Boot Yellow MegaLine® Patch 4P EC7/EC7 MegaLine® Patch 4P EC7/RJ45 MegaLine® Patch 4P EC7/open 4-pair EC7 plug 4-pair EC7 plug 4-pair EC7 plug RJ45 plug 4-pair EC7 plug Open (e.g. for self-assembly of an RJ45 plug) Patch cord and connection cable Equipment at end A Equipment at end B Plug rear view Plug rear view Plug rear view Assignment Open end 1 2 3 4 5 6 7 8 RJ45 front view EC7/RJ45: 1/2-4/5, 3/4-7/8, 5/6-2/1, 7/8-3/6 EC7/EC7: 1/1 Length Article 1.0 2.0 3.0 5.0 Order no. Article Yellow (LSOH) m LKD 9KEC 1020 0000 LKD 9KEC 1030 0000 LKD 9KEC 1050 0000 Article Order no. Yellow (LSOH) LKD 9KEC 1010 0000 MegaLine® Patch 4P EC7/EC7 (1 piece) Order no. Yellow (LSOH) LKD 9KEC 2010 0000 MegaLine® Patch 4P EC7/RJ45 (1 piece) LKD 9KEC 2020 0000 LKD 9KEC 2030 0000 LKD 9KEC 2050 0000 MegaLine® Patch 4P EC7/open (1 piece) LKD 9KEC 0050 0000 www.leoni-infrastructure-datacom.com Office DataCenter Industry 129 MegaLine® Patch cord and connection cable EC7 MegaLine® Cu patch cords / trunk cables 2-pair, shielded, with coloured boots MegaLine® Patch 2P EC7/EC7 MegaLine® Patch 2P EC7/open MegaLine® Patch 2P EC7/RJ45 MegaLine® Patch 2P EC7/RJ45 Cross over Description Construction Patch cord and connection cable for Gigabit Ethernet. Cable type 2 p, Light grey RAL 7035 Boot Grey or yellow MegaLine® Patch 2P EC7/EC7 MegaLine® Patch 2P EC7/open MegaLine® Patch 2P EC7/RJ45 MegaLine® Patch 2P EC7/RJ45 Cross over 2-pair EC7 plug 2-pair EC7 plug 2-pair EC7 plug Open (e.g. for self-assembly of an RJ45 plug) 2-pair EC7 plug RJ45 plug 2-pair EC7 plug RJ45 plug Patch cord and connection cable Equipment at end A Equipment at end B Plug rear view Plug rear view Plug rear view Plug rear view 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Open end Assignment EC7 rear view RJ45 front view EC7/EC7: 1/1 Length Article Order no. EC7/RJ45: 1/2, 3/6 for Ethernet Article Grey (LSOH) m Order no. Article Grey (LSOH) Order no. LKD 9KE0 1005 0000 LKD 9KE0 3005 0000 1.0 LKD 9KE0 1010 0000 LKD 9KE0 3010 0000 2.0 3.0 5.0 LKD 9KE0 1020 0000 LKD 9KE0 1030 0000 LKD 9KE0 1050 0000 www.leoni-infrastructure-datacom.com MegaLine® Patch 2P EC7/open (1 piece) MegaLine® Patch 2P EC7/RJ45 (1 piece) LKD 9KE0 2050 0000 Article Yellow (LSOH) 0.5 MegaLine® Patch 2P EC7/EC7 (1 piece) RJ45 front view EC7/RJ45: 1/2, 3/6 for Ethernet cross over LKD 9KE0 3020 0000 LKD 9KE0 3030 0000 LKD 9KE0 3050 0000 Order no. Yellow (LSOH) LKD 9KE3 1005 0000 MegaLine® Patch 2P EC7/RJ45 Cross over (1 piece) LKD 9KE3 1010 0000 LKD 9KE3 1020 0000 LKD 9KE3 1030 0000 LKD 9KE3 1050 0000 130 MegaLine® Patch cord and connection cable EC7 1-pair, shielded, with black boots MegaLine® Patch 1P EC7/EC7 MegaLine® Patch 1P EC7/open MegaLine® Patch 1P EC7/RJ10 MegaLine® Patch 1P EC7/RJ11 Description Construction Patch cord and connection cable for analogue and digital Cable type 3-core, Jet black RAL 9005 telephone systems. Boot Black MegaLine® Patch 1P EC7/EC7 MegaLine® Patch 1P EC7/open MegaLine® Patch 1P EC7/RJ10 MegaLine® Patch 1P EC7/RJ11 1-pair EC7 plug 1-pair EC7 plug 1-pair EC7 plug Open (e.g. for self-assembly of an RJ11 plug) 1-pair EC7 plug RJ10 plug 2-pair EC7 plug RJ11 plug Patch cord and connection cable Equipment at end A Equipment at end B EC7 1P rear view EC7 1P rear view oblique outer edge EC7 1P rear view oblique outer edge oblique outer edge EC7/EC7: 1/1 Article 0.5 1.0 3.0 5.0 oblique outer edge Order no. Article Order no. Article Black (PVC) LKD 9KE7 4005 0000 MegaLine® Patch 1P EC7/EC7 (1 piece) LKD 9KE7 4010 0000 LKD 9KE7 4020 0000 LKD 9KE7 4030 0000 LKD 9KE7 4050 0000 1 2 3 4 1 2 3 4 5 6 RJ10 (4/4) front view RJ11 (6/4) front view EC7/RJ10: 4/4 Black (PVC) m 2.0 oblique outer edge Open end Assignment Length EC7 1P rear view MegaLine® Patch 1P EC7/open (1 piece) MegaLine® Patch 1P EC7/RJ10 (1 piece) LKD 9KE7 5050 0000 Order no. EC7/RJ11: 6/4 Article Order no. Black (PVC) Black (PVC) LKD 9KE7 6005 0000 LKD 9KE7 8005 0000 LKD 9KE7 6010 0000 LKD 9KE7 6020 0000 LKD 9KE7 6030 0000 LKD 9KE7 6050 0000 MegaLine® Patch 1P EC7/RJ11 (1 piece) LKD 9KE7 8010 0000 LKD 9KE7 8020 0000 LKD 9KE7 8030 0000 LKD 9KE7 8050 0000 www.leoni-infrastructure-datacom.com Office DataCenter Industry 131 MegaLine® Patch cord and connection cable EC7 MegaLine® Cu patch cords / trunk cables 1-pair/2-pair, shielded, with black boots MegaLine® Patch 1P EC7/RJ45 MegaLine® Patch 2P EC7/RJ45 Description Construction Patch cord and connection cable for telephone systems. Cable type 3-core, Jet black RAL 9005 Boot Black MegaLine® Patch 1P EC7/RJ45 MegaLine® Patch 1P EC7/RJ45 MegaLine® Patch 2P EC7/RJ45 1-pair EC7 plug RJ45 plug 1-pair EC7 plug RJ45 plug 2-pair EC7 plug RJ45 plug without boot Patch cord and connection cable Equipment at end A Equipment at end B EC7 1P rear view EC7 1P rear view oblique outer edge EC7 2P rear view oblique outer edge Assignment 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 RJ45 front view RJ45 front view RJ45 front view For digital telephony Length Article m 0.5 1.0 2.0 3.0 MegaLine® Patch 1P EC7/RJ45 (1 piece) 5.0 www.leoni-infrastructure-datacom.com Order no. For analogue telephony For terminals with earthing key Article Order no. EC7/RJ45: 3/6, 4/5 for ISDN Article Order no. Black (PVC) Black (PVC) Black (PVC) LKD 9KE7 9005 0000 LKD 9KE8 0005 0000 LKD 9KE6 7005 0000 LKD 9KE7 9010 0000 LKD 9KE7 9020 0000 LKD 9KE7 9030 0000 LKD 9KE7 9050 0000 MegaLine® Patch 1P EC7/RJ45 (1 piece) LKD 9KE8 0010 0000 LKD 9KE8 0020 0000 LKD 9KE8 0030 0000 LKD 9KE8 0050 0000 MegaLine® Patch 2P EC7/RJ45 (1 piece) LKD 9KE6 7010 0000 LKD 9KE6 7020 0000 LKD 9KE6 7030 0000 LKD 9KE6 7050 0000 132 MegaLine®  Trunk cable, industrial VarioKeystone® cable plug Cat. 7, pre-assembled With documented acceptance measurement on CD on request (page 79) With documented acceptance measurement on CD on request (page 79) Trunk Contact block: white/white Crossconnect trunk Contact block: white/red MegaLine® Trunk cable MegaLine® Crossconnect trunk cable Description Description The data cable is assembled with cable plugs at both ends. The data cable is assembled with cable plugs at both ends. Ideal for clean rooms or for fast manipulation on site. During Ideal for clean rooms or for fast manipulation on site. During pre-assembly, the cable plug is moulded with a casting pre-assembly, the cable plug is moulded with a casting compound that simultaneously protects against bending. compound that simultaneously protects against bending. The pre-assembled cable is supplied as a ring. The pre-assembled cable is supplied as a ring. Construction Construction Material Full metal; die-cast zinc, nickel-plated Material Cable MegaLine®F10-115 S/F AWG 23/1 Cable (Order no.: LKD 7KS7 0008 0000) Full metal; die-cast zinc, nickel-plated MegaLine®F10-115 S/F AWG 23/1 (Order no.: LKD 7KS7 0008 0000) Side A VarioKeystone® cable plug Cat. 7 Side A VarioKeystone® cable plug Cat. 7 Side B VarioKeystone® cable plug Cat. 7 Side B VarioKeystone® cable plug Cat. 7 Assignment 1:1 Assignment Crossconnect Shielding Large-surface 360° shield connection Shielding Large-surface 360° shield connection Contact block: white/white Electrical values Category 7 Contact block: white/red Electrical values Category 7 Standards Standards ■■ ISO/IEC 11801 ■■ EN 50173-1 Article MegaLine® Trunk cable Length Order no. 10.0 m LKD 9A06 0095 0000 15.0 m LKD 9A06 0096 0000 20.0 m LKD 9A06 0097 0000 30.0 m LKD 9A06 0099 0000 40.0 m LKD 9A06 0101 0000 50.0 m LKD 9A06 0103 0000 Standard lengths, further lengths and cable types (also assembled at one end) on request ■■ ISO/IEC 11801 ■■ EN 50173-1 Article MegaLine® Crossconnect trunk cable Length Order no. 10.0 m LKD 9A06 0129 0000 15.0 m LKD 9A06 0130 0000 20.0 m LKD 9A06 0131 0000 30.0 m LKD 9A06 0133 0000 40.0 m LKD 9A06 0135 0000 50.0 m LKD 9A06 0137 0000 Standard lengths, further lengths and cable types (also assembled at one end) on request www.leoni-infrastructure-datacom.com Office Industry DataCenter 133 MegaLine®  Trunk cable With documented acceptance measurement on CD on request (page 79) With documented acceptance measurement on CD on request (page 79) Trunk Contact block: white/white Crossconnect trunk Contact block: white/red MegaLine® Trunk cable MegaLine® Crossconnect trunk cable Description Description The data cable is assembled with cable plugs at both ends. The data cable is assembled with cable plugs at both ends. Ideal for clean rooms or for fast manipulation on site. During Ideal for clean rooms or for fast manipulation on site. During pre-assembly, the cable plug is moulded with a casting pre-assembly, the cable plug is moulded with a casting compound that simultaneously protects against bending. compound that simultaneously protects against bending. The pre-assembled cable is supplied as a ring. The pre-assembled cable is supplied as a ring. ■■ Oil resistant acc. to ICEA S-82-552 (+60 °C) Construction ■■ Oil resistant acc. to ICEA S-82-552 (+60 °C) Construction Material Full metal; die-cast zinc, nickel-plated Material Full metal; die-cast zinc, nickel-plated Cable MegaLine®F10-130 Vö AWG 22/1 Cable MegaLine®F10-130 Vö AWG 22/1 (Order no.: LKD 7KS7 0089 0000) (Order no.: LKD 7KS7 0089 0000) Side A VarioKeystone® cable plug Cat. 7 Side A VarioKeystone® cable plug Cat. 7 Side B VarioKeystone® cable plug Cat. 7 Side B VarioKeystone® cable plug Cat. 7 Assignment 1:1 Assignment Crossconnect Shielding Large-surface 360° shield connection Shielding Crossconnect Contact block: white/white Electrical values Category 7 Large-surface 360° shield connection Electrical values Contact block: white/red Category 7 Standards Standards ■■ ISO/IEC 11801 ■■ ISO/IEC 11801 ■■ EN 50173-1 ■■ EN 50173-1 Article MegaLine® Trunk cable Length* Order no. 15.0 m LKD 9A06 0201 0000 20.0 m LKD 9A06 0202 0000 30.0 m LKD 9A06 0204 0000 40.0 m LKD 9A06 0206 0000 50.0 m LKD 9A06 0208 0000 Standard lengths, further lengths and cable types (also assembled at one end) on request www.leoni-infrastructure-datacom.com Article MegaLine® Crossconnect trunk cable Length* Order no. 15.0 m LKD 9A06 0231 0000 20.0 m LKD 9A06 0232 0000 30.0 m LKD 9A06 0234 0000 40.0 m LKD 9A06 0236 0000 50.0 m LKD 9A06 0238 0000 Standard lengths, further lengths and cable types (also assembled at one end) on request MegaLine® Cu patch cords / trunk cables VarioKeystone® cable plug Cat. 7, pre-assembled 134 MegaLine® Trunk cable, 8 port RJ45 Shielded, Cat. 6, Class EA MegaLine® Trunk RJ45 plug/RJ45 plug Description Pre-assembled trunk cable, 8 ports equipped with RJ45 plugs at both ends. Construction Cable type F10-120 S/F flex 8x4P AWG 26/7 Side A RJ45 plug, grey boot Side B RJ45 plug, grey boot Labels 16 x laminated label, printed according to customer's Whip length specification Electrical values 0.4 m Cat. 6, Class EA Standards ■■ ISO/IEC 11801 ■■ EN 50173-1 Length Article Order no. 20.0 m MegaLine® Trunk RJ45 plug/RJ45 plug (1 piece) LKD 9A06 0929 0000 Standard length, further lengths on request www.leoni-infrastructure-datacom.com Office Industry DataCenter 135 MegaLine®  Trunk cable, 4 port/8 port With documented acceptance measurement on CD on request. MegaLine® Trunk cable, 4 port MegaLine® Trunk cable, 8 port Description Construction The data cable is assembled with cable plugs at both ends. Material Full metal; die-cast zinc, nickel-plated Ideal for clean rooms or for fast manipulation on site. During Assignment 1:1 pre-assembly, the cable plug is moulded with a casting Shielding Large-surface 360° shield connection compound that simultaneously protects against bending. Contact block: white The pre-assembled cable is supplied as a ring. Electrical values Cable Standards Type MegaLine®F10-115 S/F 4x4P AWG 23/1 (Order no.: LKD 7KS7 0161 0000) MegaLine®F10-120 S/F flex 8x4P AWG 26/7 (Order no.: LKD 7KS7 0142 0000) Side A VarioKeystone® cable plug Cat. 7 Side B VarioKeystone® cable plug Cat. 7 Whip length 0.4 m Article Length* Order no. MegaLine® Trunk cable 4 port 10.0 m LKD 9A06 1019 0000 15.0 m LKD 9A06 1020 0000 5.0 m LKD 9A06 0192 0000 MegaLine® Trunk cable 8 port 7.5 m LKD 9A06 0193 0000 10.0 m LKD 9A06 0194 0000 15.0 m LKD 9A06 0195 0000 Standard lengths, further lengths and cable types (also assembled at one end) on request www.leoni-infrastructure-datacom.com ■■ Category 7 ISO/IEC 11801  n  EN 50173-1 MegaLine® Cu patch cords / trunk cables VarioKeystone® cable plug Cat. 7, pre-assembled 136 MegaLine® Connect45 trunk cable Pre-assembled single cable with MegaLine® Connect45 jack modules Cat. 6A/Cat. 6A With documented acceptance measurement on CD on request. Jack module Cat. 6A white Jack module Cat. 6A aqua MegaLine® Connect45 Trunk Cat. 6A modules MegaLine® Connect45 Trunk Cat. 6A modules Description Construction – VarioKeystone® jack modules The trunk cable is based on an F6-90 S/F data cable with Cable F6-90 S/F (4x2x AWG 23/1) Thanks to the high quality of the components, the pre-assembled Side A/side B MegaLine® Connect45 Cat. 6A (ISO/IEC) cable meets all permanent link requirements (>1 m, Cat. 6A (version 1) (Order no.: LKD 9A50 2010 0000) to ISO/IEC 11801 and EN 50173 for 10 Gigabit Ethernet. Side A/side B MegaLine® Connect45 Cat. 6A (EIA/TIA) The lengths relate to the 2-connector model. (version 2) (Order no.: LKD 9A50 2020 0000) a MegaLine® Connect45 jack at both ends. modules) or (>10 m, Cat. 6A modules) from Class EA according Also available without a jack module – ideal in combination with high-density patch panels (see page 101). Standards n  ISO/IEC 11801  n EN 50173-1 n  IEC60603-7-51 (Cat. 6A)  n  EIA/TIA 568-C.2 (Cat. 6A) Article Jack module format VarioKeystone® MegaLine® Connect45 Trunk Keystone Construction – Keystone jack modules Cable F6-90 S/F (4x2x AWG 23/1) Side A/side B MegaLine® Connect45 Cat. 6A (ISO/IEC) (version 1) (Order no.: LKD 9A50 1010 0000) Side A/side B MegaLine® Connect45 Cat. 6A (EIA/TIA) (version 2) (Order no.: LKD 9A50 1020 0000) Length* Cat. 6A modules Cat. 6A modules 5.0 m LKD 9A06 1173 0000 — 10.0 m LKD 9A06 1174 0000 — 15.0 m LKD 9A06 1175 0000 — 30.0 m LKD 9A06 1176 0000 — 90.0 m LKD 9A06 1177 0000 — 5.0 m LKD 9A06 1132 0000 LKD 9A06 1127 0000 10.0 m LKD 9A06 1133 0000 LKD 9A06 1128 0000 15.0 m LKD 9A06 1134 0000 LKD 9A06 1129 0000 30.0 m LKD 9A06 1135 0000 LKD 9A06 1130 0000 90.0 m LKD 9A06 1136 0000 LKD 9A06 1131 0000 * Standard lengths/further lengths on request www.leoni-infrastructure-datacom.com Office Industry DataCenter 137 MegaLine® Connect45 Trunk, 8 port With documented acceptance measurement on CD on request. Jack module Cat. 6A aqua MegaLine® Connect45 Trunk, 8 port Cat. 6A modules Description Construction – VarioKeystone® jack modules The trunk cable is based on an 8-fold F10-120 S/F flex data cable Cable F10-120 S/F flex (8x4x2x AWG 26/7) Side A/side B MegaLine® Connect45 Cat. 6A with a MegaLine® Connect45 jack at both ends. Thanks to the high quality of the components, the pre-assembled cable meets all permanent link requirements (Order no.: LKD 9A50 2010 0000) (>1 m, Cat. 6A modules) from Class EA according to ISO/IEC 0.4 m Whip length 11801 and EN 50173 for 10 Gigabit Ethernet. Construction – Keystone jack modules Also available without a jack module – ideal in combination Cable F10-120 S/F flex (8x4x2x AWG 26/7) Side A/side B MegaLine® Connect45 Cat. 6A with high-density patch panels (see page 101). (Order no.: LKD 9A50 1010 0000) Whip length 0.4 m Standards ■■ Article Jack module format VarioKeystone® MegaLine® Connect45 Trunk, 8 port Keystone * Standard lengths/further lengths on request www.leoni-infrastructure-datacom.com ISO/IEC 11801  n  EN 50173-1  n IEC60603-7-51 Length* Cat. 6A modules 5.0 m LKD 9A06 1178 0000 7.5 m LKD 9A06 1179 0000 10.0 m LKD 9A06 1180 0000 15.0 m LKD 9A06 1181 0000 5.0 m LKD 9A06 1137 0000 7.5 m LKD 9A06 1138 0000 10.0 m LKD 9A06 1139 0000 15.0 m LKD 9A06 1140 0000 MegaLine® Cu patch cords / trunk cables Pre-assembled multi cable with MegaLine® Connect45 jack modules Cat. 6A 138 MegaLine® Connect45 CP cable Pre-assembled single cable with MegaLine® Connect45 jack modules Cat. 6A/Cat. 6A With documented acceptance measurement on CD on request. Jack module Cat. 6A VarioKeystone® format Jack module Cat. 6A Keystone format MegaLine® Connect45 CP cable Description Construction – VarioKeystone® jack modules The consolidation point cable is based on an F10-120 S/F flex Cable F10-120 S/F flex (4x2x AWG 26/7) a RJ45 SmartLock plug at the other. Side A MegaLine® Connect45 Cat. 6A (ISO/IEC) Thanks to the high-quality components in combination Side B data cable with a MegaLine® Connect45 jack at one end and (Order no.: LKD 9A50 2010 0000) RJ45 plug (SmartLock Cat. 6A) with a CP Link (>10 m), the pre-assembled cable meets the requirements of the Class EA permanent link according Construction – Keystone jack modules to ISO/IEC 11801 Amendment 2 for 10 Gigabit Ethernet. Cable F10-120 S/F flex (4x2x AWG 26/7) Standards Side A MegaLine® Connect45 Cat. 6A (ISO/IEC) ■■ ISO/IEC 11801  n  EN 50173-1  n IEC60603-7-51 (Order no.: LKD 9A50 1010 0000) Side B Article Jack module format VarioKeystone® MegaLine® Connect45 CP cable Keystone Length* RJ45 plug (SmartLock Cat. 6A) Cat. 6A modules 5.0 m LKD 9A02 3353 0000 10.0 m LKD 9A02 3354 0000 15.0 m LKD 9A02 3355 0000 20.0 m LKD 9A02 3356 0000 25.0 m LKD 9A02 3357 0000 5.0 m LKD 9A02 3343 0000 10.0 m LKD 9A02 3344 0000 15.0 m LKD 9A02 3345 0000 20.0 m LKD 9A02 3346 0000 25.0 m LKD 9A02 3347 0000 * Standard lengths/further lengths on request www.leoni-infrastructure-datacom.com Office Industry DataCenter 139 MegaLine® EC7 CP cable MegaLine® Cu patch cords / trunk cables Shielded, Cat. 7, Class F MegaLine® EC7 CP cable Description Trunk and consolidation point cable, assembled with an ELine 1200® EC7 plug and an ­ELine 1200® EC7 plug. Construction Cable type F10-120 S/F flex 1x4P AWG 26/7 Side A ELine 1200® EC7 plug Side B ELine1200® EC7 jack Electrical values Cat. 7, Class F Standards ■■ ISO/IEC 11801 ■■ EN 50173-1 Length Article Order no. 5.0 m LKD 9KEJ 8050 0000 10.0 m LKD 9KEJ 8100 0000 15.0 m 20.0 m MegaLine® EC7 CP cable (1 piece) LKD 9KEJ 8150 0000 LKD 9KEJ 8200 0000 25.0 m LKD 9KEJ 8250 0000 30.0 m LKD 9KEJ 8300 0000 www.leoni-infrastructure-datacom.com 140 MegaLine® Patch accessories MegaLine® Patch accessories for LED patch cords for RJ45 patch cords MegaLine® Patch LED colour clip MegaLine® Patch LED detector MegaLine® Patch RJ45 colour coding clip Accessories Accessories Colour clip: Colour coding clip for visual coding of the patch cords. For visual coding of the LED patch cords. Can be installed by simply pushing on. Can be installed by simply snapping into the RJ45 plugs. Compatibility MegaLine® Patch 5D-RJ45 MegaLine® Patch 6E-RJ45U MegaLine® Patch 6EA-RJ45 MegaLine® Patch 6AEA-RJ45 MegaLine® Patch Industry 6EA-RJ45 Detector: For feeding the light signal for identifying the patch cord. Batteries included: 4 x LR41 Order no. Article Colour Order no. Article Colour ● Rape yellow RAL 1021 LKD 9A09 0180 0000 ● Light grey RAL 7035 LKD 9AW1 6031 0000 MegaLine® Patch LED colour clip (100 pieces) ● Flame red RAL 3000 LKD 9A09 0181 0000 ● Turquoise green RAL 6016 LKD 9AW1 6032 0000 ● Sky blue RAL 5015 LKD 9A09 0182 0000 ● Turquoise green RAL 6016 LKD 9A09 0183 0000 MegaLine® Patch LED detector (1 piece) LKD 9A09 0190 0000 ● Sky blue RAL 5015 MegaLine® Patch RJ45 colour coding clip ● Flame red RAL 3000 (100 pieces) ● Pastel orange RAL 2003 LKD 9AW1 6033 0000 LKD 9AW1 6034 0000 LKD 9AW1 6035 0000 ● Rape yellow RAL 1021 LKD 9AW1 6036 0000 ● Jet black RAL 9005 LKD 9AW1 6037 0000 www.leoni-infrastructure-datacom.com Office DataCenter Industry 141 MegaLine® Test report MegaLine® Cu patch cords / trunk cables for all trunk cables Also order Measurements for trunks The measurement carried out prior to delivery can be documen- ➔ Permanent link Class EA (with ISO/IEC jack module) ted on CD as a test report and supplied on request. ➔ Permanent link Class EA (with EIA/TIA jack module) ➔ Channel Class EA (with ISO/IEC jack module) ➔ Channel Class EA (with EIA/TIA jack module) Measurements for CP cables ➔ Permanent link Class EA (with ISO/IEC jack module) Acceptance measurements ➔ Channel Class FA ➔ Permanent link Class F ➔ Permanent link Class EA ➔ Channel Class EA (with Cat. 6 module) ➔ Channel Class EA (with Cat. 6 Product family MegaLine® Connect45 MegaLine® Connect45 VarioKeystone® Measurement for trunks for CP cable for trunks www.leoni-infrastructure-datacom.com A module) Acceptance measurement Order no. Permanent link Class EA (with ISO/IEC jack module) LKD 9A50 4020 0000 Permanent link Class E A (with EIA/TIA jack module) LKD 9A50 4021 0000 Channel Class E A (with ISO/IEC jack module) LKD 9A50 4022 0000 Channel Class E A (with EIA/TIA jack module) LKD 9A50 4023 0000 Permanent link Class E A (with ISO/IEC jack module) LKD 9A50 4024 0000 Channel Class FA LKD 9A46 0132 0000 Permanent link Class F LKD 9A46 0123 0000 Permanent link Class E A LKD 9A46 0125 0000 Channel Class E A (with Cat. 6A module) LKD 9A46 0131 0000 Channel Class E A (with Cat. 6 module) LKD 9A46 0126 0000 142 MegaLine® Acceptance measurement www.leoni-infrastructure-datacom.com Office Industry DataCenter 143 Acceptance measurement of the MegaLine® cabling systems The acceptance measurement for the MegaLine® cabling systems for the channel or permanent link is carried out in accordance with the requirements of  SO/IEC 11801 or EN 50173, 2nd Edition Amendment 1/2. Further standards regarding the acceptance measurement (measurement procedure): DIN EN 50346 and DIN EN 61935. www.leoni-infrastructure-datacom.com 144 Channel Class E/EA/F/FA Frequency/MHz 1 16 100 250 Return loss 19.0 18.0 12.0 8.0 Insertion loss 4.0 8.3 21.7 35.9 500 600 1000 Channel Class E NEXT 65.0 53.2 39.9 33.1 PS NEXT/dB 62.0 50.6 37.1 30.2 ACR-N/dB 61.0 44.9 18.2 –2.8 PS-ACR-N/dB 58.0 42.3 15.4 –5.8 ACR-F/dB 63.3 39.2 23.3 15.3 PS-ACR-F/dB 60.3 36.2 20.3 12.3 Runtime/µs 0.580 0.553 0.548 0.546 Runtime difference/µs 0.050 0.050 0.050 0.050 Return loss 19.0 18.0 12.0 8.0 6.0 Insertion loss 4.0 8.2 20.9 33.9 49.3 Channel Class E A NEXT 65.0 53.2 39.9 33.1 27.9 PS NEXT/dB 62.0 50.6 37.1 30.2 24.8 ACR-N/dB 61.0 45.0 19.0 –0.8 –21.4 PS-ACR-N/dB 58.0 42.4 16.2 –3.7 –24.5 ACR-F/dB 63.3 39.2 23.3 15.3 9.3 PS-ACR-F/dB 60.3 36.2 20.3 12.3 6.3 Runtime/µs 0.580 0.553 0.548 0.546 0.546 Runtime difference/µs 0.050 0.050 0.050 0.050 0.050 Return loss 19.0 18.0 12.0 8.0 49.3 8.0 Insertion loss 4.0 8.1 20.8 33.8 52.4 54.6 Channel Class F NEXT 65.0 65.0 62.9 56.9 49.4 51.2 PS NEXT/dB 62.0 62.0 59.9 53.9 3.1 48.2 ACR-N/dB 61.0 56.9 42.1 23.1 0.1 –3.4 PS-ACR-N/dB 58.0 53.9 39.1 20.1 32.6 –6.4 ACR-F/dB 65.0 57.5 44.4 37.8 29.6 31.3 PS-ACR-F/dB 62.0 54.5 41.4 34.8 8.0 28.3 Runtime/µs 0.580 0.553 0.548 0.546 0.546 0.545 Runtime difference/µs 0.030 0.030 0.030 0.030 0.03 0.030 Return loss 19.0 18.0 12.0 8.0 8.0 8.0 6.0 Insertion loss 4.0 8.0 20.3 32.5 46.7 51.4 67.6 Channel Class FA NEXT 65.0 65.0 65.0 59.1 53.6 52.1 47.9 PS NEXT/dB 62.0 62.0 62.0 56.1 50.6 49.1 44.9 ACR-N/dB 61.0 57.0 44.7 26.7 6.9 0.7 –19.6 PS-ACR-N/dB 58.0 54.0 41.7 23.7 3.9 –2.3 –22.6 ACR-F/dB 65.0 63.3 47.4 39.4 33.4 31.8 27.4 PS-ACR-F/dB 62.0 60.3 44.4 36.4 30.4 28.8 24.4 Runtime/µs 0.580 0.553 0.548 0.546 0.546 0.545 0.545 Runtime difference/µs 0.030 0.030 0.030 0.030 0.030 0.030 0.030 www.leoni-infrastructure-datacom.com Office Industry DataCenter 145 Permanent link Frequency/MHz 1 16 100 250 500 600 1000 Permanent link Class E 21.0 20.0 14.0 10.0 Insertion loss Return loss 4 7.1 18.5 30.7 NEXT 65 54.6 41.8 35.3 PS Next/dB 62 52.2 39.3 32.7 ACR-N/dB 61 47.5 23.3 4.7 PS ACR-N/dB 58 45.1 20.8 2 64.2 40.1 24.2 16.2 ACR-F/dB PS ACR-F/dB 61.2 37.1 21.2 13.2 Runtime/µs 0.521 0.496 0.491 0.490 Runtime difference/µs 0.044 0.044 0.044 0.044 Permanent link Class EA Return loss 21.0 20.0 14.0 10.0 8.0 Insertion loss 4 7 17.8 28.9 42.1 NEXT 65 54.6 41.8 35.3 29.2/27.9* PS Next/dB 62 52.2 39.3 32.7 26.4/24.8* ACR-N/dB 61 47.6 24 6.4 –12.9/14.2* PS ACR-N/dB 58 45.2 21.5 3.8 –15.7/16.3* ACR-F/dB 64.2 40.1 24.2 16.2 10.2 PS ACR-F/dB 61.2 37.1 21.2 13.2 7.2 Runtime/µs 0.521 0.496 0.491 0.490 0.490 Runtime difference/µs 0.044 0.044 0.044 0.044 0.044 Permanent link Class F 21.0 20.0 14.0 10.0 10.0 10.0 Insertion loss Return loss 4 6.9 17.7 28.8 42.1 46.6 NEXT 65 65 65 60.4 55.9 54.7 PS Next/dB 62 62 62 57.4 52.9 51.7 ACR-N/dB 61 58.1 47.3 31.6 13.8 8.1 PS ACR-N/dB 58 55.1 44.3 28.6 10.8 5.1 ACR-F/dB 65 59.3 46 39.2 34 32.6 PS ACR-F/dB 62 56.3 43 36.2 31 29.6 Runtime/µs 0.521 0.496 0.491 0.490 0.490 0.489 Runtime difference/µs 0.026 0.026 0.026 0.026 0.026 0.026 Permanent link Class FA Return loss 21.0 20.0 14.0 10.0 10.0 10.0 8.0 Insertion loss 4 6.8 17.3 27.7 39.8 43.9 57.6 NEXT 65 65 65 61.7 56.1 54.7 49.1/47.9* PS Next/dB 62 62 62 58.7 53.1 51.7 46.1/44.9* ACR-N/dB 61 58.2 47.7 34 16.4 10.8 –8.5/9.7* PS ACR-N/dB 58 55.2 44.7 31 13.4 7.8 –11.5/12.7 ACR-F/dB 65 64.7 48.8 40.8 34.8 33.2 28.8 PS ACR-F/dB 62 61.7 45.8 37.8 31.8 30.2 25.8 Runtime/µs 0.521 0.496 0.491 0.490 0.490 0.489 0.489 0.026 0.026 0.026 0.026 0.026 0.026 0.026 Runtime difference/µs * = 3-connector link www.leoni-infrastructure-datacom.com MegaLine® Cu data cables Class E/EA/F/FA 146 Acceptance measurement Class EA VarioKeystone® RJ45/MegaLine® Connect45 The measuring device is set to the measuring bandwidth Make sure that the measuring adapter is connected to the of 500 MHz for the acceptance measurement according measuring device and firmly engaged. Take the corresponding to Class EA. measuring cable and make sure that it is firmly plugged in. If synchronisation is required, this is then carried out according Refer to the instructions on setting the measuring device. to the instructions for the device. Information can be found under: www.idealindustries.de/www.flukenetworks.com. Standard acceptance: Channel or permanent link VarioKeystone® RJ45 Ideal LanTEK II/7G (available from Ideal Industries) Fluke DTX 1800 (available from Fluke Networks) Measuring cable set Order no.: 9A024414 MegaLine® Connect45 Ideal LanTEK II/7G (available from Ideal Industries) Fluke DTX 1800 (available from Fluke Networks) Measuring cable set Order no.: 9A024414 System Approved measuring devices Approved measuring cables www.leoni-infrastructure-datacom.com Office Industry DataCenter 147 Acceptance measurement Class F VarioKeystone® 4K7/ELine 1200® EC7 The measuring device is set to the measuring Make sure that the measuring adapter is connected to the bandwidth of 600 MHz for the acceptance measurement measuring device and firmly engaged. Take the corresponding according to Class F. measuring cable and make sure that it is firmly plugged in. If synchronisation is required, this is then carried out according Refer to the instructions on setting the measuring device. to the instructions for the device. Information can be found under: www.idealindustries.de/www.flukenetworks.com Standard acceptance: Channel or permanent link Standard acceptance: Channel or permanent link VarioKeystone® 4K7 Ideal LanTEK II/7G (available from Ideal Industries) EC7 measuring adapter (channel) (available from Ideal Industries) Measuring cable set (Order no.: LKD 9ZE3 0053 0000) ELine 1200® EC7 Ideal LanTEK II/7G (available from Ideal Industries) EC7 measuring adapter (channel) (available from Ideal Industries) Measuring cable set (Order no.: 9ZE30057) ELine 1200® EC7 Fluke DTX 1800 (available from Fluke Networks) EC7 measuring adapter (permanent link) (Order no.: 9ZE30038) System www.leoni-infrastructure-datacom.com Approved measuring devices Approved measuring adapters Approved measuring cables 148 Acceptance measurement Class FA ELine 1200® EC7 The measuring device is set to the measuring bandwidth Make sure that the measuring adapter is connected to the of 1,000 MHz for the acceptance measurement according measuring device and firmly engaged. Take the corresponding to Class FA. measuring cable and make sure that it is firmly plugged in. Next carry out the field zero adjustment according to the instructions Refer to the instructions on setting the measuring device. for the device. Information can be found under: www.idealindustries.de/www.flukenetworks.com Standard acceptance: Channel or permanent link ELine 1200® EC7 System Ideal LanTEK II/7G (available from Ideal Industries) Approved measuring devices EC7 measuring adapter (available from Ideal Industries) Approved measuring adapters Measuring cable set (Order no.: 9ZE30057) Approved measuring cables www.leoni-infrastructure-datacom.com Office Industry DataCenter 149 www.leoni-infrastructure-datacom.com 150 Alien crosstalk AlienX (AXT) EMI NIC 10Gbit/s 10Gbit/s Switch NEXT FEXT Return Loss Transmission model and alien crosstalk 10GBASE- T Alien crosstalk describes the undesirable mutual electrical These characteristics are design-specific and do not change influence between parallel links in the installation duct and in the installation environment. IEEE 802.3an considers shielded in the vicinity of the patch fields. In contrast to NEXT and cabling systems to be the preferred solution. attenuation, disturbance through alien crosstalk cannot be compensated for electronically. Alien crosstalk has become extremely important from a technical point of view. ISO/IEC 11801 Amendment 1 (Generic cabling for customer premises) takes this into account with relevant specifications for the new transmission classes EA (500 MHz) and FA (1,000 MHz). MegaLine® S/FTP cabling systems meet the requirements for alien crosstalk with a high degree of reliability. External Frequency MHz Minimum PS ANEXT dB Class E A, F Class FA 1 67.0 67.0 100 60.0 67.0 250 54.0 67.0 500 49.5 64.5 1,000 N/A 60.0 Requirements for PS Alien Next and PS AACR-F at selected frequencies influences from adjacent channels are prevented and suppressed simultaneously via the double shielding of the S/FTP cables and the modular shielding of the connectivity. Alien crosstalk is attenuated by >100 dB (a factor of 100,000). Frequency MHz 1 Minimum PS AACR-F db Class EA, F Class FA 67.0 67.0 100 37.0 52.0 250 29.0 44.0 500 23.0 38.0 1,000 N/A 32.0 Requirements for PS Alien Next and PS AACR-F at selected frequencies www.leoni-infrastructure-datacom.com Office Industry DataCenter 151 Alien crosstalk configuration with MegaLine®: 6 "culprits" and 1 "victim" Coupling attenuation MegaLine® test results Coupling attenuation evaluates the overall EMC behaviour All MegaLine® cabling systems with modular or individual of a cable or individual link. The coupling attenuation consists shielding have met the extended requirements for coupling of the shielding attenuation and the asymmetrical attenuation attenuation according to Class EA. ELine 1200® EC7 and taken together and defines the degree of reduction of electrical VarioKeystone® 4K7 even meet the requirements according influences on a signal path. to Class FA. It was possible to conclude the comprehensive assessments with the relevant certifications If the coupling attenuation for Class EA is 10.0 dB better or for Class FA links is 25.0 dB better than in the table below, the values for the parameters Power Sum Alien NEXT (PS ANEXT) and Power Sum Alien ACR-F (PS AACR‑F) are complied with automatically as a result of the design, making it unnecessary to demonstrate them explicitly. Class Frequency MHz Min. coupling attenuation dB D, E, E A, F, FA 30 ≤ ƒ ≤ Note 2 80 – 20lg(ƒ) Coupling attenuation (Class E A) of VarioKeystone® RJ45 Note 1: Round down calculated values of greater than 40 db to 40 dB. Note 2: Coupling attenuation is measured to 1,000 MHz but the limit is determined by the upper frequency of the class being tested. Requirements for coupling attenuation for cabling classes D to FA Coupling attenuation for Class EA and F: > 90 – 20 log(f), > 50 dB up to 100 MHz Coupling attenuation for Class FA: > 105 – 20 log(f), > 65 dB up to 100 MHz Due to the coupling mechanisms, this connection only applies for shielded cablings and not for unshielded ones. www.leoni-infrastructure-datacom.com Coupling attenuation (Class FA) of ELine 1200® EC7 152 GigaLine FO data cables ® www.leoni-infrastructure-datacom.com Office Industry DataCenter 153 Page GigaLine® FO data cables The fiber 154 GigaLine® FO data cables For LAN, WAN and SAN 157 GigaLine® fiber qualities 158 GigaLine® colour codes 159 GigaLine® type codes 160 Jacketing material for optical cables 161 Rodent protection for fiber optic cables 162 Pictograms 163 Handling and safety notices 164 GigaLine® FO data cables 165 o dc GigaLine® indoor cable, duplex fig 8 KL-I-V(ZN)H 2 G/E 165 o dc i GigaLine® indoor cable, duplex fig 0 KL-I-V(ZN)HH 2 G/E 166 o dc GigaLine® indoor cable, mini breakout KL-I-V(ZN)H n G/E 167 o dc i GigaLine® breakout cable KL-I-V(ZN)HH n G/E 168 o dc i GigaLine® universal cable, mini breakout 800 N KL-U-VQ(ZN)H n G/E 169 o dc i GigaLine® universal cable, central 2,500 N KL-U-DQ(ZN)BH 1xn G/E 170 o dc i GigaLine® universal cable, stranded 4,000 N KL-U-DQ(ZN)BH nxm G/E 171 o dc i GigaLine® universal cable, central 2,500 N KL-U-DQ(ZN)H(SR)H 1xn G/E 172 LEONI "fire secured" FO data cables 173 o dc i GigaLine® "fire secured" universal cable, central with CI KL-U-D(ZN)BH 1xn G/E Total system integrity at least 90 min 174 o dc i GigaLine® "fire secured" universal cable, central with CI KL-U-DQ(ZN)H(SR)H 1xn G/E Total system integrity at least 120 min 175 o i GigaLine® outdoor cable, central 1,750 N KL-A-DQ(ZN)B2Y 1xn G/E 176 o i GigaLine® outdoor cable, stranded 4,000 N KL-A-DQ(ZN)B2Y nxm G/E 177 o i GigaLine® outdoor cable, central 1,750 N KL-A-DQ(ZN)2Y(SR)2Y 1xn G/E 178 o i GigaLine® outdoor cable, stranded 4,000 N KL-A-DQ(ZN)2Y(SR)2Y nxm G/E 179 o i GigaLine® outdoor cable, stranded with sheath 4,000 N KL-A-DF (ZN)(L) 2y nxm G/E 180 o Office cables dc i DataCenter cables Industrial cables www.leoni-infrastructure-datacom.com GigaLine® FO data cables GigaLine® FO data cables 154 GigaLine® FO data cables The fiber The steady increase in Internet and intranet traffic, multimedia applications and the establishment of central storage networks (SAN or Storage Area Networks) in companies have fundamentally changed the traffic and load distribution in networks. New media require new, more powerful passive network infrastructures. LEONI offers a future-proof cabling system with reserves well beyond those stipulated in the standards. Comparison of requirements Fiber category OM1 G62.5/125 Fiber category OM1 G62.5/125 for Standard and GigaGrade at 850 nm at 1,300 nm LEONI OM1e GigaGrade G62.5/125 M Standard OM1 Attenuation LEONI OM1e GigaGrade G62.5/125 M Standard OM1 3.5 dB/km 3.0 dB/km 1.5 dB/km 0.8 dB/km 200 MHz x km 250 MHz x km 500 MHz x km 800 MHz x km Gigabit Ethernet segment length 275 m 500 m 550 m 1,000 m 10 Gigabit Ethernet segment length 32 m 65 m 300 m 450 m Modal bandwidth Comparison of requirements Fiber category OM2 G50/125 Fiber category OM2 G50/125 for Standard and GigaGrade at 850 nm at 1,300 nm Standard OM2 Attenuation LEONI OM2 Standard GigaGrade G50/125 LEONI OM2e High Performance GigaGrade G50/125 Standard OM2 LEONI OM2 Standard GigaGrade G50/125 LEONI OM2e High Performance GigaGrade G50/125 3.5 dB/km 2.7 dB/km 2.5 dB/km 1.5 dB/km 0.8 dB/km 0.7 dB/km 500 MHz x km 500 MHz x km 600 MHz x km 500 MHz x km 500 MHz x km 1,200 MHz x km Gigabit Ethernet segment length 550 m 550 m 750 m 550 m 550 m 2,000 m 10 Gigabit Ethernet segment length 82 m 82 m 150 m 300 m 300 m 700 m Modal bandwidth The right fiber GigaGrade multimode fibers LEONI offers a comprehensive range of optical fibers tailored to GigaGrade G62.5/125 and GigaGrade G50/125 are the reliable the various network requirements such as future-proof high- and proven fibers for network technology in industrial performance transmission in DataCenters, reliable office applications and in office cabling in the categories OM1 networks and stable industrial networks. and OM2. The optimum multimode fiber for every application: GigaGrade GigaGrade OptiGrade 300 OptiGrade 550 OM1 OM2 OM3 OM4 LAN DataCenter LAN Office LAN Industry www.leoni-infrastructure-datacom.com Office Industry DataCenter Comparison of requirements Fiber category OM3 G50/125 Fiber category OM3 G50/125 for Standard and OptiGrade at 850 nm at 1,300 nm LEONI OM3 OptiGrade 300 Standard OM3 Attenuation LEONI OM3 OptiGrade 300 Standard OM3 3.5 dB/km 2.5 dB/km 1.5 dB/km 0.7 dB/km Modal bandwidth (overfilled launch) 1,500 MHz x km 1,500 MHz x km 500 MHz x km 500 MHz x km EMB (effective modal bandwidth) 2,000 MHz x km 2,000 MHz x km n.a. n.a. Gigabit Ethernet segment length 550 m 900 m 550 m 550 m 10 Gigabit Ethernet segment length 300 m 300 m 300 m 300 m 40/100 Gigabit Ethernet segment length 100 m 100 m 100 m 100 m Comparison of requirements Fiber category OM4 G50/125 Fiber category OM4 G50/125 for Standard and OptiGrade at 850 nm at 1,300 nm Standard OM4 LEONI OM4 OptiGrade 550 Standard OM4 LEONI OM4 OptiGrade 550 2.5 dB/km 2.5 dB/km 1.5 dB/km 0.7 dB/km Modal bandwidth (overfilled launch) 3,500 MHz x km 3,500 MHz x km 500 MHz x km 500 MHz x km EMB (effective modal bandwidth) 4,700 MHz x km 4,700 MHz x km n.a. n.a. Gigabit Ethernet segment length 550 m 1,000 m 550 m 550 m 10 Gigabit Ethernet segment length 550 m 550 m 300 m (LX4) 300 m (LX4) 40/100 Gigabit Ethernet segment length 150 m 150 m 150 m 150 m Attenuation OptiGrade 300 for 10 GbE networks OptiGrade 550 future-proof without comprises The sophisticated IT cabling in DataCenters and office buildings, The OptiGrade 550 multimode fiber fulfils the requirements with a 10 Gigabit Ethernet-compatible network, is based on the of the OM4 standard for the serial transmission of 10 Gb/s with laser-optimised OptiGrade 300 OM3 fiber. an EMB of 4,700 MHz x km over 550 m. The fiber has been optimised for applications with 850 nm VCSEL and offers the possibility of use at higher transmission rates such as 40 Gb/s or 100 Gb/s going into the future. OptiGrade 550 is the first choice when it comes to speed and high data rates. www.leoni-infrastructure-datacom.com GigaLine® FO data cables 155 156 Fiber category OS2 E9/125 (G.652.D) Comparison of requirements for Standard and j-LWP SMF+ Attenuation Attenuation at 1,383 nm at 1,310 nm at 1,550 nm Standard OS2 IEC 60793-2-50 B6_a LEONI OS2 j-LWP SMF+ Standard OS2 IEC-60793-2 50-B1.3 LEONI OS2 j-LWP SMF+ 0.40 dB/km 0.36 dB/km 0.30 dB/km 0.23 dB/km < 0.40 dB/km 0.36 dB/km ­— — 1 Gigabit Ethernet segment length 5,000 m 5,000 m ­— — 10 Gigabit Ethernet segment length 10,000 m 10,000 m 22,250 m 40,000 m 40 Gigabit Ethernet segment length 10,000 m 10,000 m ­— ­— Fiber category E9/125 (G.657.A) Comparison of requirements for Standard and j-LBL SMF Attenuation Attenuation at 1,383 nm at 1,310 nm at 1,550 nm Standard OS2 IEC 60793-2-50 B6_a LEONI OS2 low bend j-LBL SMF Standard OS2 IEC 60793-2-50 B6_a LEONI OS2 low bend j-LBL SMF 0.40 dB/km 0.36 dB/km 0.30 dB/km 0.23 dB/km < 0.40 dB/km 0.36 dB/km ­— — 1 Gigabit Ethernet segment length 5,000 m 5,000 m — — 10 Gigabit Ethernet segment length 10,000 m 10,000 m 22,250 m 40,000 m 40 Gigabit Ethernet segment length 10,000 m 10,000 m — — 100 Gigabit Ethernet segment length 10,000/40,000 m 10,000/40,000 m — — j-LWP SMF+ proven for long links j-LBL SMF flexible and compatible The low-water-peak singlemode fiber, j-LWP SMF+ as per ITU-T The j-LBL SMF as per ITU-T G657.A is a high-performance field- G652.D or as per EN 50173 OS2, offers the best transmission tested singlemode fiber for applications where the need for performance across the entire wavelength range from 1,260 compatibility with installed G.652.D networks is linked with nm to 1,625 nm. The fiber can be used in the wavelength the requirement for improved bending characteristics for sturdy, ranges from 1,360 nm to 1,480 nm due to the reliably stable, low flexible and space-saving installations. The j-LBL SMF offers attenuation at 1,383 nm. The j-LWP SMF+ is the preferred fiber maximum transmission performance with minimum attenuation. wherever maximum flexibility and long transmission lengths are Due to the reliably and permanently low attenuation at required. The use of WDM systems enables the full spectrum of 1,383 nm, it can be used in the wavelength range from fiber capacity to be used – the prerequisite for flexible network 1,360 nm to 1,480 nm and the fiber is therefore also suitable planning. The fiber is fully compatible with installed singlemode for wavelength multiplexing (DWDM and CWDM). networks and enables network solutions with maximum The fiber exhibits excellent splicing properties thanks to its Attenuation [dB] performance and flexibility. 30 25 first-rate uniformity and geometry. This means it is backwards Bending sensitivity at different wavelengths 1,310 nm 1,550 nm 1,625 nm compatible with already installed conventional singlemode fibers (to ITU-T G.652.A+B) and low-water-peak singlemode fibers (to ITU-T G.652 C+D). 20 Bending characteristics 15 Macro-bending losses, bending-induced attenuation 10 5 0 8 10 12 14 16 18 20 Bend diameter [mm] Values Unit ≤ 0.03 dB 10 bends, radius 15 mm 1,550 nm 1,652 nm ≤ 0.20 dB 1 bend, radius 10 mm 1,550 nm ≤ 0.30 dB 1,625 nm ≤ 1.00 dB www.leoni-infrastructure-datacom.com Office Industry DataCenter 157 GigaLine® FO data cables The use of fiber optic data cables is especially The process used to manufacture the fibers has been optimised recommended if… in such a way that the profile of the multimode fiber is ■■ electromagnetic influences can occur extremely precise and disturbances in the fiber core are virtually ■■ reliable potential isolation is required eliminated. As differential mode delay does not occur under ■■ a wide transmission bandwidth is required these circumstances, mode-conditioning patch cords are not ■■ low attenuation and therefore long transmission links necessary. For more than ten years now, the standard versions are required of fiber optic cables with an improved gradient fiber G50/125 ■■ crosstalk is not permitted from the category "OM2e" have provided bandwidth-length ■■ sparking (for areas subject to explosion hazards) is not products of 600 MHz x km in the first window (850 nm) and permitted 1,200 MHz x km in the second window (1,300 nm) as well as ■■ low weight and small dimensions are an advantage Gigabit Ethernet segment lengths of 750/2,000 m. ■■ increased security against interception is required GigaLine® fiber optic cables with OM3 and OM4 fibers are The product range at a glance: ■■ the optimum transmission medium, whatever the future Easy-to-assemble indoor cables with compact buffered fiber might hold. technology for the patch and horizontal areas ■■ Universal cables for the backbone area indoors and outdoors Using the OM4 fibers with a laser bandwidth of 4,700 MHz x km ■■ Outdoor cables for LAN and WAN applications in the first window enables segment lengths of up to 550 m ■■ A wide range of designs such as outdoor cables with with 10 GbE, up to 300 m with 16 GB/s Fiberchannel or up to – corrugated steel cladding 150 m with 40 and 100 GbE. This in turn enables cost-effective – steel band or steel wire armour realisation of 10 GbE in the backbone of a building in nearly – additional lead covering as protection against chemicals all cases. Gigabit, 10, 40 and 100 Gigabit Ethernet – strictest Singlemode fibers must be used over long distances. The requirements for the quality of the fiber optic cabling. singlemode fibers exceed the current requirements of the The Ethernet protocol is the state of the art today in every OS2 standard according to EN 50173-1 with attenuation of just area of structured cabling. The corresponding standards for 0.36 dB/km at 1,310 nm and less than 0.22 db/km at 1,550 nm. transmission rates from 1 Gigabit/s to 100 Gigabit/s are defined in IEEE 802.3ba. This means that the wavelength ranges around 1,383 nm can also be used to increase the transmission capacity. The graph shows the steadily dropping attenuation curve from 1,300 nm Comparison SMF G652B/G652D to 1,625 nm for all singlemode fibers. These characteristics and Attenuation [dB/km] the PMD link design value of just 0.06 ps/ km guarantee large n ITU T 652B 0.8 n ITU T 652D and WDM transmission systems. The use of high-quality optical fibers is the key to managing 0.6 future data volumes. GigaLine® fiber optic data cables 0.4 are the first step in careful planning and implementation of a passive network infrastructure. 0.2 0 1250 1300 1350 1400 1450 1500 1550 1600 1650 Wavelength [nm] www.leoni-infrastructure-datacom.com reserves for faster transmission rates over very long distances GigaLine® FO data cables for LAN, WAN and SAN 158 GigaLine® Fiber qualities Fiber specifications GigaGrade G62.5/125 GigaGrade G50/125 GigaGrade G50/125 OM1e OM2 OM2e OptiGrade IEC 11801/EN 50173 IEC 60793-2 A1b OptiGrade 300 OptiGrade 550 G50/125 G50/125 OM3 OM4 j-LWP SMF+ E9...10/125 j-LWP SMF+ E9...10/125 OS2 OS2 low bend A1a.1 A1a.1 A1a.2 A1a.3 B1.3 B6_a G.651 G.651 G.651 G.651 G.652.D G.657.A max. 2.7 max. 0.8 max. 2.5 max. 0.7 max. 2.5 max. 0.7 max. 2.5 max. 0.7 max. 0.36 max. 0.40 max. 0.23 max. 0.23 max. 0.36 max. 0.40 max. 0.23 max. 0.23 at 1,310 nm max. 3.5 ps/nm x km max. 3.5 ps/nm x km at 1,550 nm max. 18 ps/nm x km max. 18 ps/nm x km ITU-T Attenuation coefficient dB/km at 850 nm dB/km at 1,300 nm max. 3.0 max. 0.7 dB/km at 1,310 nm dB/km at 1,383 nm dB/km at 1,550 nm dB/km at 1,625 nm Bandwidth MHz x km at 850 nm min. 250 min. 500 min. 600 min. 1,500 min. 3,500 MHz x km at 1,300 nm min. 800 min. 500 min. 1,200 min. 500 min. 500 min. 2,000 min. 4,700 Laser bandwidth MHz x km at 850 nm Dispersion Zero-dispersion wavelength Zero-dispersion slope 1,302 ≤ λ0 ≤ 1,322 1,302 ≤ λ0 ≤ 1,322 ≤ 0.092 ps/nm² x km ≤ 0.092 ps/nm² x km PMD Fiber < 0.1 ps/ km < 0.1 ps/ km Link < 0.06 ps/ km < 0.06 ps/ km 5,000 m 5,000 m 10,000 m 10,000 m 40,000 m 40,000 m 10,000 m 10,000 m 0.12 0.12 Segment length with Gigabit Ethernet at 850 nm (1000 base SX) 500 m 550 m 750 m 900 m 1,000 m at 1,300 nm (1000 base LX) 1,000 m 550 m 2,000 m 550 m 550 m Segment length with 10 Gigabit Ethernet at 850 nm (10G base-SR/SW) 65 m 82 m 150 m 300 m 550 m at 1,300 nm (10G base-LX4) 450 m 300 m 700 m 300 m 300 m at 1,550 nm (10G base-ER/EW) Segment length with 40/100 Gigabit Ethernet at 850 nm 40/100 GBASE-SR4/SR10 100 m 150 m at 1,310 nm 40/100 GBASE-LR4 Numerical aperture Nominal value 0.275 0.20 0.20 0.20 0.20 at 850 nm 1.497 1.483 1.483 1.483 1.483 at 1,300 nm 1.493 1.478 1.478 1.478 1.478 Refractive index (nominal value) at 1,310 nm 1.467 1.467 at 1,550 nm 1.467 1.467 Test load 100 kpsi ≥ 8.8 N www.leoni-infrastructure-datacom.com Office Industry DataCenter 159 Wires (with stranded loose tubes) Counting wire Red Counting direction wire White Other wires Green for G50/125 Fibers (in loose tubes) IEC 60304 Fiber no. Fiber no. Colour Colour 1 Blue 1 Red 2 Orange 2 Green 3 Green 3 Blue Yellow for E9…10/125 4 Brown 4 Yellow Natural colours 5 Grey 5 White Grey Blue for G62.5/125 Dummy elements Mini breakout cable EIA/TIA 598C The wires are consecutively counted, starting with the wire closest to the counting element. The dummy elements are not counted. 6 White 6 7 Red 7 Brown 8 Black 8 Violet 9 Yellow 9 Turquoise Black 10 www.leoni-infrastructure-datacom.com Violet 10 11 Pink 11 Orange 12 Turquoise 12 Pink 13 Red/black 14 Green/black 15 Blue/black 16 Yellow/black 17 White/black 18 Grey/black 19 Brown/black 20 Violet/black 21 Turquoise/black 22 Natural/black 23 Orange/black 24 Pink/black GigaLine® FO data cables GigaLine® Colour codes 160 GigaLine® Type codes for easy assignment of the construction elements in fiber optic cables GigaLine® 1 2 3 4 5 6 7 8 9 Cable type Communication cable KL Field of application Indoor cable I Universal cable U Outdoor cable A Breakout outdoor cable AT Buffered fiber Tight buffered loose tube V Gel-filled loose tube D Constructional composition Swelling material, dry, longitudinally watertight Q Water-blocking gel-filled, longitudinally watertight F Non-metallic strain relief (ZN) Steel strain relief (ZS) Armour B Corrugated steel tape SR Cable sheath PE Polyethylene sheath 2Y Al + PE PE coated aluminium sheath (L)2Y FRNC Halogen-free/flame-retardant sheath H PVC Polyvinyl chloride sheath Y PA Polyamide sheath 4Y PUR Polyurethane sheath 11Y Fiber number and fiber bundling Number of fibers n Number of loose tubes x number of fibers per  tube nxm Miscellaneous n Field diameter/sheath diameter in… E9/125 n Core diameter/sheath diameter in… G50/125 or G62.5/125 Wavelength 850 nm B 1,300/1,310 nm F 1,550 nm H Bandwidth/dispersion coefficient in MHz · km with multimode fibers, dispersion parameters in ps/nm · km with singlemode fibers www.leoni-infrastructure-datacom.com Office Industry DataCenter 161 Jacketing material for optical cables Balancing application and fire prevention criteria The sheath around the cable protects the optical fiber(s) from However, it is often extremely difficult to meet all the the effects of mechanical, thermal and chemical action as requirements using just one sheath material. To best satisfy well as the ingress of moisture. In the event of a fire, however, the prevailing local operating conditions, LEONI offers a choice the cable sheath should prevent a fire from spreading and stop of different materials. toxic and corrosive gases from being produced. Please contact us if the criteria for your particular application The use of halogen-free, flame-retardant materials is advisable are not met by the cable constructions in this catalogue. in order to protect equipment and buildings but above all Additional requirements can often be met through customised to protect people. In harsh environments, PUR and PVC, measures when making the sheath (e.g. aluminium tape or in particular, are used owing to their high resistance to oils and special mixtures of sheaths). material for outdoor applications. Cable sheath material Material characteristics FRNC PUR PVC PE Resistance to aging + + + + Halogen-free + + –– + Flame retardancy + ● + – –/● Elasticity – + ● – Abrasion resistance – ++ + +/– Low smoke gas generation ++ ● – – –/● Low emission of corrosive gases ++ ● –– +/● Low smoke gas toxicity ++ ● –– +/● No toxicological risk ++ ● – +/● General resistance to FRNC PUR PVC PE UV light 1) 1) 1) 1) Water absorption – – + + Gas diffusion – 2) – ● Fuels – + +/– + Petroleum/lubricants – ++ ● + Organic solvents – + 3) – + 4) Alcohol – – + + Oxidants – – + – Acids + –– + ++ Alkaline solutions + –– + + Saline solutions + – + + www.leoni-infrastructure-datacom.com ++ excellent + good ● depends on recipe – weak – – inadequate 1) UV resistance can be increased by adding black colour pigments or UV stabilisers 2) Permeation depends on the type of gas, e.g. Ar, CH4, N2, O2 low gas permeation, CO2, H2, He higher gas permeation 3) Low swelling in saturated hydrocarbons; significant swelling in aromatic hydrocarbons. Aliphatic esters cause swelling, highly polar organic solvents dissolve under the effect of extreme swelling 4) Swelling in aliphatic and aromatic hydrocarbons and in chlorinated hydrocarbons GigaLine® FO data cables their abrasion resistance. PE is also commonly used as a sheath 162 Rodent protection for fiber optic cables Fiber optic cables are relatively thin and therefore very susceptible to rodent damage. Depending on the application it is important that fiber optic cables can offer protection against this type of damage. There are no national or indeed international standards or test specifications covering the corresponding requirement for rodent protection. The following construction has been customary in the market in Metal armouring must be recommended as rodent protection Europe (particularly in Germany, Austria and Switzerland) since for all applications where rodent damage is to be expected. This the early 1990s: is the case, for example, with installation in shafts or conduits For outdoor cables, the usual aramid yarns for strain relief are with a correspondingly large diameter, e.g. along railway lines replaced with glass rovings. These glass yarns shatter and get or motorways. into the mouth and throat of the rodents. The animals associate gnawing on cables with pain and usually stop. The following types of metal armouring are available: ■■ Corrugated steel cladding The general rule is: The most common metal armouring is the 0.155 mm thick The more glass rovings, the greater the protection for corrugated steel cladding due to its very good flexibility. the cable. ■■ Steel wire armour The steel wire armour made from wires with a thickness of up to 1.25 mm is very robust. The overall diameter should also be as large as possible. Constructions with stranded loose tubes give even less ■■ Steel band favourable leverage in combination with the larger core Steel band sheathing consists of two overlapping layers diameter. The cable then acts like a gag bit. Before the rodent of steel band that are wound around the cable. reaches the glass rovings, however, it first has to gnaw through the outer sheath. Constructions with an additional polyamide In the case of cables with two sheaths with sheathing between sheath (thickness 0.5 mm) have also proven themselves here them, the ingress of water into the cable core is also prevented as polyamide is very hard and smooth. provided the internal sheath is not damaged. This combination of plastic, glass and moisture-absorbing Despite all precautions, however, damage to the outer swelling material has to be gnawed through before rodent sheath can never be fully ruled out. reaches the loose tubes containing the internal optical fibers. www.leoni-infrastructure-datacom.com Office Office Industry DataCenter 163 Pictograms Flame-retardant and halogen-free sheath The outer sheath of the cable is self-extinguishing and does not propagate fire. The halogen-free sheath material forms neither toxic nor corrosive combustion gases in the event of fire. Rodent proof The cable core is protected against damage by rodents with glass rovings. Note: Despite all the precautions, damage to the outer sheath can never be fully ruled out. Rodent proof The cable core is more heavily protected against damage by rodents with two sheaths and metal armouring. Note: Despite all the precautions, damage to the outer sheath can never be fully ruled out. Resistance to UV rays The cable outer sheath is resistant to UV rays. Longitudinal watertightness Water in the cable core cannot spread out in longitudinal direction. Lateral watertightness Lateral diffusion of water into the cable core is prevented. www.leoni-infrastructure-datacom.com GigaLine® FO data cables Chemical resistance Generally good resistance to oil, petrol, acids and alkaline solutions. 164 Handling and safety notices when using optical cables Please note the following when installing optical fibers: ■■ Valid installation regulations for optical fibers ■■ Valid industrial safety guidelines for handling optical fibers ■■ VDE regulations (DIN EN 50174 Parts 1 to 3, Cabling installation) The following regulations also apply: ■■ The drums must always be stored and transported standing on their flanges ■■ Immersion with water must be avoided – the fibers and connectors must not come into contact with water ■■ Do not remove the protective packaging from the cable ends during installation All cable ends must be protected from the ingress of moisture before, during and after installation ■■ Please note the limit values specified in the respective data sheet ■■ ■■ Optical fibers must be unwound from the coil or ring without torsion so that no kinks or twists can occur ■■ Install optical cables with extreme care. Please make sure ■■ Do not go below the permitted bending radius (see data sheet) that the fibers are neither overstretched nor compressed – ■■ Avoid soiling and mechanical loading of the assembled in addition to immediate damage, this also poses the threat connectors of problems with the long-term behaviour ■■ Do not exceed the maximum tensile load of the cable in axial ■■ these have no sharp edges and that kinks are avoided direction during and after installation (use suitable aids) ■■ The maximum tensile load only applies in conjunction with ■■ adhesion with the strain relief elements ■■ warranty claims may arise ■■ Cable runs must be selected so as to avoid mechanical loads Mechanical stresses, for example caused by movement, must Body and eye protection must be worn when handling bare fibers from glass optical fibers, including if the cable as far as possible and also minimise future loads ■■ The attenuation of each cable must be checked immediately after installation using a suitable calibrated meter, otherwise Installation is not permitted if the ambient temperature is exceeded or gone below (specific value in the data sheet) ■■ When installing in protective conduits, please make sure that is damaged ■■ Please note all regulations relating to eye safety be prevented, even during provisional installation ■■ Compression of the outer sheath, for example by cable ties, must be avoided when securing the cables ■■ After installation: carefully free the cable ends from the packaging/pull tool www.leoni-infrastructure-datacom.com Office DataCenter Industry 165 GigaLine® Indoor cable, duplex fig 8 Type KL-I-V(ZN)H 2 G/E Outer sheath Strain relief elements Description Thermal characteristics Connection cable and patch cord for structured cabling acc. Transport/storage –25 °C up to +70 °C to ISO/IEC 11801 and EN 50173 (2nd edition). Installation –5 °C up to +50 °C Operating temperature –10 °C up to +70 °C GigaLine® FO data cables Semi-tight buffered fiber In keeping with the fiber type ideal for all applications from Classes OF 300 to OF 10000. Suitable for direct connector Mechanical characteristics assembly. Min. bending radius Installation in dry areas, in cable ducts, on cable trays Max. crush strength or in conduits. static 30 mm dynamic 60 mm long-term 600 N/dm short-term 1000 N/dm Construction Fire performance Two single cables (2.8 mm with 900 µm semi-ight buffered Smoke density IEC 61034 loose tubes) with strain relief in figure 8 sheath with separator Halogen free IEC 60754-1 Strain relief Non-metallic (aramid yarns) Flame retardancy IEC 60332-1-2, IEC 60332-3-24 Cable sheath Halogen-free, flame-retardant compound Sheath colour OS2 ● Yellow ● Orange OM1e/OM2e ● Aqua OM3 ● Heather violet OM4 Fiber number Buffered Overall fiber diam. Weight type approx. approx. kg/km Max. strain relief Fire load approx. N MJ/m kWh/m Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 µ mm 2 900 2.8x5.7 15.8 600 0.36 0.10 LKD 8DB7 0003 0000 LKD 8DA2 0003 0000 LKD 8DA5 2000 0000 LKD 8DA7 2000 0000 LKD 8DC7 2001 0000 2 600 1.8x3.7 7 400 0.14 0.04 LKD 8XB7 0013 0000 www.leoni-infrastructure-datacom.com LKD 8XA2 0013 0000 LKD 8XA5 2013 0000 LKD 8XA7 0013 0000 LKD 8XC7 0013 0000 166 GigaLine® Indoor cable, duplex fig 0 Type KL-I-V(ZN)HH 2 G/E Outer sheath Strain relief Semi-tight buffered fiber Subcable sheath Description Thermal characteristics Connection cable and patch cord for structured cabling acc. Transport/storage –25 °C up to +70 °C to ISO/IEC 11801 and EN 50173 (2nd edition). Installation –5 °C up to +50 °C Operating temperature –10 °C up to +70 °C In keeping with the fiber type ideal for all applications from Classes OF 300 to OF 10000. Suitable for direct connector Mechanical characteristics assembly. Min. bending radius Installation in dry areas, in cable ducts, on cable trays or in conduits. static 35 mm dynamic 65 mm for single elements 30 mm Max. tensile force long-term 600 N Max. crush strength long-term 500 N/dm short-term 750 N/dm Construction Two single cables (2.1 mm with 900 µm semi-tight buffered fibers) with strain relief running parallel under one sheath Fire performance Strain relief Non-metallic (aramid yarns) Smoke density IEC 61034 Cable sheath Halogen-free, flame-retardant compound Halogen free IEC 60754-1 Sheath colour OS2 Flame retardancy IEC 60332-1-2, IEC 60332-3-24 ● Yellow ● Orange OM1e/OM2e ● Aqua OM3 Further characteristics: ● Heather violet OM4 Cable bending Fiber number 2 Overall diam. approx. Weight approx. Max. strain relief Fire load approx. mm kg/km N MJ/m kWh/m 3.1x5.2 18 600 0.63 0.18 IEC 60794-1-2 E11 Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 LKD 8DB7 0011 0000 LKD 8DA2 0011 0000 LKD 8DA5 2001 0000 LKD 8DA7 2005 0000 LKD 8DC7 0010 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 167 GigaLine® Indoor cable, mini breakout Type KL-I-V(ZN)H n G/E Outer sheath Strain relief Description Thermal characteristics Campus/backbone cabling, suitable for direct connector Transport/storage –25 °C up to +70 °C assembly. Connection cable and patch cord for structured Installation –5 °C up to +50 °C cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Operating temperature –10 °C up to +70 °C In keeping with the fiber type ideal for all applications from Classes OF 300 to OF 10000. Mechanical characteristics Min. bending radius static 10 x overall diameter dynamic 15 x overall diameter Construction for single Up to 12 semi-tight buffered fibers (900 µm) stranded under elements 30 mm Max. tensile force long-term 600 N Max. crush strength long-term 500 N/dm short-term 1000 N/dm one outer sheath Strain relief Non-metallic (aramid yarns) Cable sheath Halogen-free, flame-retardant compound Sheath colour OS2 ● Yellow ● Orange OM1e/OM2e Fire performance ● Aqua OM3 ● Heather violet OM4 Smoke density IEC 61034 Halogen free IEC 60754-1 Flame retardancy IEC 60332-1-2, IEC 60332-3-24 Further characteristics: Cable bending Fiber number Overall diam. approx. Weight approx. Max. strain relief Fire load approx. mm kg/km N MJ/m kWh/m IEC 60794-1-2 E11 Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2e E9…10/125 2 4.2 14 800 0.45 0.13 LKD 8MB7 0011 0000 LKD 8MA2 0011 0000 LKD 8MA5 2011 0000 LKD 8MA7 0011 0000 LKD 8MC7 0011 0000 4 4.8 21 800 0.47 0.13 LKD 8MB7 0012 0000 LKD 8MA2 0012 0000 LKD 8MA5 2012 0000 LKD 8MA7 0012 0000 LKD 8MC7 0012 0000 6 5.9 25 800 0.50 0.14 LKD 8MB7 0013 0000 LKD 8MA2 0013 0000 LKD 8MA5 2013 0000 LKD 8MA7 0013 0000 LKD 8MC7 0013 0000 LKD 8MB7 0014 0000 LKD 8MA2 0014 0000 LKD 8MA5 2014 0000 LKD 8MA7 0014 0000 LKD 8MC7 0014 0000 8 6.1 30 800 0.52 0.14 10 7.0 38 800 0.53 0.14 LKD 8MB7 0015 0000 LKD 8MA2 0015 0000 LKD 8MA5 2015 0000 LKD 8MA7 0015 0000 LKD 8MC7 0015 0000 12 7.0 38 800 0.55 0.15 LKD 8MB7 0016 0000 LKD 8MA2 0016 0000 LKD 8MA5 2016 0000 LKD 8MA7 0016 0000 LKD 8MC7 0016 0000 www.leoni-infrastructure-datacom.com GigaLine® FO data cables Tight buffered fiber 168 GigaLine® Breakout cable Type KL-I-V(ZN)HH n G/E Outer sheath Strain relief Central element Semi-tight buffered fiber Subcable sheath Description Thermal characteristics Connection cable and patch cord for structured cabling acc. Transport/storage –25 °C up to +70 °C to ISO/IEC 11801 and EN 50173 (2nd edition). Installation –5 °C up to +50 °C Operating temperature –10 °C up to +70 °C In keeping with the fiber type ideal for all applications from Classes OF 300 to OF 10000. Suitable for direct connector Mechanical characteristics assembly. Min. bending radius static 15 x overall diameter dynamic 20 x overall diameter Installation in dry areas, in cable ducts, on cable trays for single or in conduits. elements 30 mm long-term 1000 N/dm short-term 1500 N/dm Max. crush strength Construction Up to 12 single cables with strain relief as breakout elements (2.1 mm with 900 µm semi-tight buffered fibers) stranded under Fire performance one outer sheath Smoke density IEC 61034 Ripcord under the outer sheath Halogen free IEC 60754-1 Strain relief Non-metallic (aramid yarns) Flame retardancy IEC 60332-1-2, IEC 60332-3-24 Cable sheath Halogen-free, flame-retardant compound Sheath colour OS2 ● Yellow Further characteristics: ● Orange OM1e/OM2e Cable bending IEC 60794-1-2 E11 ● Aqua OM3 ● Heather violet OM4 Overall diam. Fiber approx. number mm 2 7.0 Weight approx. Max. strain relief Fire load approx. kg/km N MJ/m kWh/m 40 800 1.10 0.30 Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9...10/125 LKD 8BB7 0011 0000 LKD 8BA2 0011 0000 LKD 8BA5 2011 0000 LKD 8BA7 0011 0000 LKD 8BC7 0011 0000 4 7.0 45 800 1.10 0.30 LKD 8BB7 0012 0000 LKD 8BA2 0012 0000 LKD 8BA5 2012 0000 LKD 8BA7 0012 0000 LKD 8BC7 0012 0000 6 8.2 65 1000 1.18 0.32 LKD 8BB7 0013 0000 LKD 8BA2 0013 0000 LKD 8BA5 2013 0000 LKD 8BA7 0013 0000 LKD 8BC7 0013 0000 8 9.6 95 1000 1.31 0.36 LKD 8BB7 0014 0000 LKD 8BA2 0014 0000 LKD 8BA5 2014 0000 LKD 8BA7 0014 0000 LKD 8BC7 0014 0000 10 11.0 135 1000 1.42 0.39 LKD 8BB7 0015 0000 LKD 8BA2 0015 0000 LKD 8BA5 2015 0000 LKD 8BA7 0015 0000 LKD 8BC7 0015 0000 12 12.5 155 1000 1.57 0.44 LKD 8BB7 0016 0000 LKD 8BA2 0016 0000 LKD 8BA5 2016 0000 LKD 8BA7 0016 0000 LKD 8BC7 0016 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 169 GigaLine® Universal cable, mini breakout 800 N Type KL-U-VQ(ZN)H n G/E Outer sheath Strain relief Description Thermal characteristics Campus/backbone cabling, suitable for direct connector Transport/storage –25 °C up to +70 °C assembly. Connection cable and patch cord for structured Installation –5 °C up to +50 °C cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Operating temperature –25 °C up to +60 °C In keeping with the fiber type ideal for all applications from Classes OF 300 to OF 10000. House connections possible without Mechanical characteristics additional interconnection points (splices). Min. bending radius static 10 x overall diameter dynamic 15 x overall diameter Installation indoors and outdoors in dry conduits, on covered for single cable trays or in cable ducts. Mechanical pulling in with winches elements 30 mm long-term 300 N/dm short-term 500 N/dm is only permitted in conjunction with force measuring devices Max. crush strength with a logging feature. Construction Fire performance Up to 24 tight buffered fibers (900 µm) stranded under Smoke density IEC 61034 one outer sheath Halogen free IEC 60754-1 Flame retardancy IEC 60332-1-2, IEC 60332-3-24 Buffered fiber colour code acc. to EIA/TIA598C Strain relief Non-metallic (aramid yarns) Cable sheath Halogen-free, flame-retardant compound Further characteristics: Sheath colour ● Yellow Longitudinal watertightness IEC 60794-1-2 F5 Cable bending Fiber number Overall diam. approx. Weight approx. Max. strain relief Fire load approx. mm kg/km N MJ/m kWh/m IEC 60794-1-2 E11 Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9...10/125 6 5.9 25 800 0.50 0.14 LKD 8NB7 1003 0000 LKD 8NA2 1003 0000 LKD 8NA5 1003 0000 LKD 8NA7 1003 0000 LKD 8NC7 1003 0000 12 7.0 38 800 0.55 0.15 LKD 8NB7 1006 0000 LKD 8NA2 1006 0000 LKD 8NA5 1006 0000 LKD 8NA7 1006 0000 LKD 8NC7 1006 0000 24 9.4 72 800 0.92 0.25 LKD 8NB7 1009 0000 LKD 8NA2 1009 0000 LKD 8NA5 1009 0000 LKD 8NA7 1009 0000 LKD 8NC7 1009 0000 www.leoni-infrastructure-datacom.com GigaLine® FO data cables Tight buffered fiber 170 GigaLine® Universal cable, central 2500 N Type KL-U-DQ(ZN)BH 1xn G/E Outer sheath Strain relief Loose tube, gel-filled Description Thermal characteristics Installation cable, suitable for campus/backbone cabling and Transport/storage –25 °C up to +70 °C for structured cabling acc. to ISO/IEC 11801 and EN 50173 Installation –5 °C up to +50 °C (2nd edition). Ideal for all applications from Classes OF 300, OF 500, Operating temperature –25 °C up to +60 °C OF 2000, OF 5000 and OF 10000. Suitable for installation indoors in applications involving increased mechanical requirements Mechanical characteristics as well as risk of rodent damage. Suitable for splicing. House Min. bending radius connections possible without additional interconnection points (splices). Installation indoors and outdoors in conduits, on covered Max. crush strength cable trays, in cable ducts or directly in the ground (in a bed of static 15 x overall diameter dynamic 20 x overall diameter long-term 2000 N/dm short-term 3500 N/dm sand). Mechanical pulling in with winches is only permitted in conjunction with force measuring devices with a logging feature. Fire performance Smoke density IEC 61034 Construction Halogen free IEC 60754-1 Central filled loose tube with max. 24 fibers, up to 12 fibers Flame retardancy IEC 60332-1-2, IEC 60332-3-24 diameter 2.9 mm, up to 24 fibers diameter 3.5 mm Fiber colour code acc. to IEC 60304 Further characteristics: Loose tube colour: Yellow (E9/125), green (G50/125), blue (G62.5/125) Longitudinal watertightness IEC 60794-1-2 F5 Strain relief Non-metallic (glass rovings) Impact resistance IEC 60794-1-2 E4 Cable sheath Halogen-free, flame-retardant compound Cable bending IEC 60794-1-2 E11 Sheath colour ● Black Resistance to microbes Fiber number Overall Max. diam. Weight strain approx. approx. relief mm kg/km N Fire load approx. MJ/m kWh/m Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 1x2 7.6 65 2500 0.95 0.26 LKD 8UB7 00M1 0000 LKD 8UA2 00M1 0000 LKD 8UA500M1 0000 LKD 8UA7 00M1 0000 LKD 8UC7 00M1 0000 1x4 7.6 65 2500 0.95 0.26 LKD 8UB7 00M2 0000 LKD 8UA2 00M2 0000 LKD 8UA500M2 0000 LKD 8UA7 00M2 0000 LKD 8UC7 00M2 0000 1x6 7.6 65 2500 0.95 0.26 LKD 8UB7 00M3 0000 LKD 8UA2 00M3 0000 LKD 8UA500M3 0000 LKD 8UA7 00M3 0000 LKD 8UC7 00M3 0000 LKD 8UB7 00M4 0000 LKD 8UA2 00M4 0000 LKD 8UA500M4 0000 LKD 8UA7 00M4 0000 LKD 8UC7 00M4 0000 1x8 7.6 65 2500 0.95 0.26 1x10 7.6 65 2500 0.95 0.26 LKD 8UB7 00M5 0000 LKD 8UA2 00M5 0000 LKD 8UA500M5 0000 LKD 8UA7 00M5 0000 LKD 8UC7 00M5 0000 1x12 7.6 65 2500 0.95 0.26 LKD 8UB7 00M6 0000 LKD 8UA2 00M6 0000 LKD 8UA500M6 0000 LKD 8UA7 00M6 0000 LKD 8UC7 00M6 0000 1x16 8.2 73 2500 1.06 0.30 LKD 8UB7 00M7 0000 LKD 8UA2 00M7 0000 LKD 8UA500M7 0000 LKD 8UA7 00M7 0000 LKD 8UC7 00M7 0000 1x20 8.2 73 2500 1.06 0.30 LKD 8UB7 00M8 0000 LKD 8UA2 00M8 0000 LKD 8UA500M8 0000 LKD 8UA7 00M8 0000 LKD 8UC7 00M8 0000 1x24 8.2 73 2500 1.06 0.30 LKD 8UB7 00M9 0000 LKD 8UA2 00M9 0000 LKD 8UA500M9 0000 LKD 8UA7 00M9 0000 LKD 8UC7 00M9 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 171 GigaLine® Universal cable, stranded 4000 N Type KL-U-DQ(ZN)BH nxm G/E Outer sheath Strain relief Loose tube, gel-filled GFR central strength Description Thermal characteristics Installation cable, suitable for campus/backbone cabling Transport/storage –25 °C up to +70 °C and for structured cabling acc. to ISO/IEC 11801 and EN 50173 Installation –5 °C up to +50 °C (2nd edition). Ideal for applications from Classes OF 300 to Operating temperature –25 °C up to +60 °C OF 10000. Suitable for installation in applications involving increased mechanical requirements as well as risk of rodent Mechanical characteristics damage. Suitable for splicing. House connections possible without Min. bending radius additional interconnection points (splices). Installation indoors and outdoors in conduits, on covered Max. crush strength cable trays, in cable ducts or directly in the ground (in a bed of static 15 x overall diameter dynamic 20 x overall diameter long-term 3000 N/dm short-term 4000 N/dm sand). Mechanical pulling in with winches is only permitted in conjunction with force measuring devices with a logging feature. Fire performance Smoke density IEC 61034 Construction Halogen free IEC 60754-1 Stranded filled loose tube with up to 12 fibers Flame retardancy IEC 60332-1-2, IEC 60332-3-24 Fiber colour code acc. to IEC 60304 Loose tube colour: Counting wire red, counting direction wire Further characteristics: white, yellow (E9/125), green (G50/125), blue (G62.5/125) Longitudinal watertightness IEC 60794-1-2 F5 Twisting Loose tubes and if applicable dummy elements Impact resistance IEC 60794-1-2 E4 around a central strength member Cable bending IEC 60794-1-2 E11 Cable core Central GFR strength member Resistance to microbes Stranded filled loose tubes Strain relief Non-metallic (glass rovings) Cable sheath Halogen-free, flame-retardant compound Sheath colour ● Black Overall diam. Fiber approx. number mm Weight approx. Max. strain relief Fire load approx. kg/km N MJ/m kWh/m 141 4000 2x12 11.4 Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9...10/125 2.95 0.82 LKD 8UB7 1K06 0000 LKD 8UA2 1K06 0000 LKD 8UA5 1K06 0000 LKD 8UA7 1K06 0000 LKD 8UC7 1K06 0000 LKD 8UB7 1K08 0000 LKD 8UA2 1K08 0000 LKD 8UA5 1K08 0000 LKD 8UA7 1K08 0000 LKD 8UC7 1K08 0000 4x12 11.4 141 4000 2.95 0.82 8x12 13.7 200 4000 3.24 0.90 LKD 8UB7 1K11 0000 LKD 8UA2 1K11 0000 LKD 8UA5 1K11 0000 LKD 8UA7 1K11 0000 LKD 8UC7 1K11 0000 12x12 17 300 4000 4.32 1.20 LKD 8UB7 1K13 0000 LKD 8UA2 1K13 0000 LKD 8UA5 1K13 0000 LKD 8UA7 1K13 0000 LKD 8UC7 1K13 0000 Other types on request www.leoni-infrastructure-datacom.com GigaLine® FO data cables member 172 GigaLine® Universal cable, central 2500 N Type KL-U-DQ(ZN)H(SR)H 1xn G/E Strain relief Outer sheath Corrugated steel cladding Loose tube, gel-filled Description Thermal characteristics Installation cable, suitable for campus/backbone cabling and Transport/storage –25 °C up to +70 °C for structured cabling acc. to ISO/IEC 11801 and EN 50173 Installation –5 °C up to +50 °C (2nd edition). Ideal for all applications from Classes OF 300, OF 500, Operating temperature –25 °C up to +60 °C OF 2000, OF 5000 and OF 10000. Suitable for installation in applications involving increased mechanical requirements as well Mechanical characteristics as risk of rodent damage. Suitable for splicing. House connections Min. bending radius possible without additional interconnection points (splices). Installation indoors and outdoors in dry conduits, on covered Max. crush strength cable trays, in cable ducts or directly in the ground. Mechanical static 15 x overall diameter dynamic 20 x overall diameter long-term 2500 N/dm short-term 3500 N/dm pulling in with winches is only permitted in conjunction with force measuring devices with a logging feature. Fire performance Smoke density IEC 61034 Construction Halogen free IEC 60754-1 Central filled loose tube with max. 24 fibers, up to 12 fibers Flame retardancy IEC 60332-1-2, IEC 60332-3-24 diameter 2.9 mm, up to 24 fibers diameter 3.5 mm Fiber colour code acc. to IEC 60304 Further characteristics: Loose tube colour: Yellow (E9/125), green (G50/125), blue (G62.5/125) Longitudinal watertightness IEC 60794-1-2 F5 Strain relief Non-metallic (glass rovings) Impact resistance IEC 60794-1-2 E4 Inner sheath Halogen-free, flame-retardant compound Cable bending IEC 60794-1-2 E11 Inner sheath colour ● Black Armouring Resistance to microbes Corrugated steel cladding Cable sheath Halogen-free, flame-retardant compound Sheath colour ● Black Overall diam. Fiber approx. number mm Weight approx. Max. strain relief Fire load approx. kg/km N MJ/m kWh/m Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 1x2 11.6 171 2500 1.93 0.53 LKD 8UB7 99K1 0000 LKD 8UA2 99K1 0000 LKD 8UA5 99K1 0000 LKD 8UA7 99K1 0000 LKD 8UC7 99K1 0000 1x4 11.6 171 2500 1.93 0.53 LKD 8UB7 99K2 0000 LKD 8UA2 99K2 0000 LKD 8UA5 99K2 0000 LKD 8UA7 99K2 0000 LKD 8UC7 99K2 0000 1x6 11.6 171 2500 1.93 0.53 LKD 8UB7 99K3 0000 LKD 8UA2 99K3 0000 LKD 8UA5 99K3 0000 LKD 8UA7 99K3 0000 LKD 8UC7 99K3 0000 1x8 11.6 171 2500 1.93 0.53 LKD 8UB7 99K4 0000 LKD 8UA2 99K4 0000 LKD 8UA5 99K4 0000 LKD 8UA7 99K4 0000 LKD 8UC7 99K4 0000 1x10 11.6 171 2500 1.93 0.53 LKD 8UB7 99K5 0000 LKD 8UA2 99K5 0000 LKD 8UA5 99K5 0000 LKD 8UA7 99K5 0000 LKD 8UC7 99K5 0000 1x12 11.6 171 2500 1.93 0.53 LKD 8UB7 99K6 0000 LKD 8UA2 99K6 0000 LKD 8UA5 99K6 0000 LKD 8UA7 99K6 0000 LKD 8UC7 99K6 0000 LKD 8UB7 99K7 0000 LKD 8UA2 99K7 0000 LKD 8UA5 99K7 0000 LKD 8UA7 99K7 0000 LKD 8UC7 99K7 0000 1x16 12.1 181 2500 2.14 0.59 1x20 12.1 181 2500 2.14 0.59 LKD 8UB7 99K8 0000 LKD 8UA2 99K8 0000 LKD 8UA5 99K8 0000 LKD 8UA7 99K8 0000 LKD 8UC7 99K8 0000 1x24 12.1 181 2500 2.14 0.59 LKD 8UB7 99K9 0000 LKD 8UA2 99K9 0000 LKD 8UA5 99K9 0000 LKD 8UA7 99K9 0000 LKD 8UC7 99K9 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 173 LEONI "fire secured" FO data cables GigaLine® FO data cables with a fire barrier to protect the fibers in the event of a fire A functioning communication system is of vital importance in the event of a fire. It is therefore vital that a fiber optic cable maintains its total system integrity. The results of the fire tests certify that the "fire secured" fiber optic data cables maintain their total system integrity and their insulation integrity for 90 and 120 minutes respectively in the event of a fire. In particular in public facilities and buildings where large numbers of people gather (e.g. tunnels, airports, hotels, etc.), fire alarm, SOS telephone and video monitoring systems are used to coordinate rescue measures and fire fighting efforts as efficiently as possible. Also in industrial facilities, processes have to be terminated in a controlled manner in order to avoid serious secondary damage to humans and the environment. Modern communication systems are increasingly using optical data transmission systems for transmitting data. These are often the only option given the high requirements for data rates and transmission paths. With its "fire secured" universal cables, LEONI offers products which are tested according to IEC 60331-25 and EN 50200 and protect the fibers from exposure to fire thanks to their special construction with a fire barrier. www.leoni-infrastructure-datacom.com 174 GigaLine® "Fire secured" universal cable, central with CI Type KL-U-D(ZN)BH 1xn G/E Total system integrity during exposure to fire for at least 90 minutes Outer sheath Ripcord Loose tube, gel-filled Strain relief Inner fire protection barrier Description Thermal characteristics Installation cable suitable for campus/backbone cabling Transport/storage –25 °C up to +70 °C and structured cabling acc. to ISO/IEC 11801 and EN 50173 Installation – 5 °C up to +50 °C (2nd edition). Ideal for all applications from Classes OF 300 to Operating temperature –25 °C up to +60 °C OF 10000. Suitable for installation in applications involving increased mechanical requirements as well as risk of rodent Mechanical characteristics damage. Suitable for splicing. House connections possible Min. bending radius without additional interconnection points (splices). Max. crush strength Installation in dry areas, in cable ducts, on cable trays or in conduits. static 15 x overall diameter dynamic 20 x overall diameter long-term 3000 N/dm short-term 4500 N/dm Construction Fire performance Central filled loose tube with max. 24 fibers, up to 12 fibers diam.  Smoke density IEC 61034 3.5 mm, up to 24 fibers diam. 4.0 mm, with fire protection barrier Halogen free IEC 60754-1 Fiber colour code acc. to IEC 60304 Flame retardancy IEC 60332-1-2, IEC 60332-3-22 Loose tube colour: Yellow (E9/125), green (G50/125), blue (G62.5/125) Strain relief Non-metallic (glass rovings) Further characteristics: Cable sheath Halogen-free, flame-retardant compound Total system and Ripcords under the sheath insulation integrity EN 50200/DIN VDE 0482 Part 1 Sheath colour ● Yellow Acc. to IEC 60331-11 and -25 (90 minutes) Max. change in attenuation 2.0 dB Overall diam. approx. Weight approx. Max. strain relief Fire load approx. mm kg/km N MJ/m kWh/m 1x2 10.3 115 2500 1.03 0.29 LKD 8UB7 00B1 0000 LKD 8UA2 00B1 0000 LKD 8UA5 00B1 0000 LKD 8UA7 00B1 0000 LKD 8UC7 00B1 0000 1x4 10.3 115 2500 1.03 0.29 LKD 8UB7 00B2 0000 LKD 8UA2 00B2 0000 LKD 8UA5 00B2 0000 LKD 8UA7 00B2 0000 LKD 8UC7 00B2 0000 1x6 10.3 115 2500 1.03 0.29 LKD 8UB7 00B3 0000 LKD 8UA2 00B3 0000 LKD 8UA5 00B3 0000 LKD 8UA7 00B3 0000 LKD 8UC7 00B3 0000 LKD 8UB7 00B4 0000 LKD 8UA2 00B4 0000 LKD 8UA5 00B4 0000 LKD 8UA7 00B4 0000 LKD 8UC7 00B4 0000 Fiber number Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 1x8 10.3 115 2500 1.03 0.29 1x10 10.3 115 2500 1.03 0.29 LKD 8UB7 00B5 0000 LKD 8UA2 00B5 0000 LKD 8UA5 00B5 0000 LKD 8UA7 00B5 0000 LKD 8UC7 00B5 0000 1x12 10.3 115 2500 1.03 0.29 LKD 8UB7 00B6 0000 LKD 8UA2 00B6 0000 LKD 8UA5 00B6 0000 LKD 8UA7 00B6 0000 LKD 8UC7 00B6 0000 1x16 10.8 125 2500 1.28 0.36 LKD 8UB7 00B7 0000 LKD 8UA2 00B7 0000 LKD 8UA5 00B7 0000 LKD 8UA7 00B7 0000 LKD 8UC7 00B7 0000 1x20 10.8 125 2500 1.28 0.36 LKD 8UB7 00B8 0000 LKD 8UA2 00B8 0000 LKD 8UA5 00B8 0000 LKD 8UA7 00B8 0000 LKD 8UC7 00B8 0000 1x24 10.8 125 2500 1.28 0.36 LKD 8UB7 00B9 0000 LKD 8UA2 00B9 0000 LKD 8UA5 00B9 0000 LKD 8UA7 00B9 0000 LKD 8UC7 00B9 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 175 GigaLine® "Fire secured" universal cable, central with CI Type KL-U-DQ(ZN)H(SR)H 1xn G/E Total system integrity during exposure to fire for at least 120 minutes Outer sheath Corrugated steel cladding Inner sheath Strain relief Description Thermal characteristics Installation cable suitable for campus/backbone cabling Transport/storage –25 °C up to +70 °C and structured cabling acc. to ISO/IEC 11801 and EN 50173 Installation –5 °C up to +50 °C (2nd edition). For applications from Classes OF 300 to OF 10000. Operating temperature –25 °C up to +60 °C Suitable for installation in applications involving increased mechanical requirements as well as risk of rodent damage. Mechanical characteristics Suitable for splicing. House connections possible without Min. bending radius additional interconnection points (splices). Installation indoors and outdoors in dry conduits, on covered cable trays or in cable Max. crush strength ducts. Mechanical pulling in with winches is only permitted in static 15 x overall diameter dynamic 20 x overall diameter long-term 2500 N/dm short-term 3500 N/dm conjunction with force measuring devices with a logging feature. Fire performance Construction Smoke density IEC 61034 Central filled loose tubes with max. 24 fibers, up to 12 fibers diam. 3.5 Halogen free IEC 60754-1 mm, up to 24 fibers diam. 4.0 mm, fiber colour code acc. to IEC 60304 Flame retardancy IEC 60332-1-2, IEC 60332-3-22 Loose tube colour: Yellow (E9/125), green (G50/125), blue (G62.5/125) Strain relief Non-metallic (glass rovings) Inner sheath Halogen-free, flame-retardant compound Armouring Corrugated steel sheath as fire protection barrier and rodent protection Cable sheath Halogen-free, flame-retardant compound Sheath colour ● Yellow Fiber number Overall diam. approx. Weight approx. Max. strain relief Fire load approx. mm kg/km N MJ/m kWh/m Further characteristics: Total system and Acc. to IEC 60331-11 and -25 insulation integrity EN 50200: 2000 Class PH120 & BS 8434: 2003 Part 2 (120 minutes) Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 1x2 12.5 215 2500 2.80 0.78 LKD 8UB7 00C1 0000 LKD 8UA2 00C1 0000 LKD 8UA5 00C1 0000 LKD 8UA7 00C1 0000 LKD 8UC7 00C1 0000 1x4 12.5 215 2500 2.80 0.78 LKD 8UB7 00C2 0000 LKD 8UA2 00C2 0000 LKD 8UA5 00C2 0000 LKD 8UA7 00C2 0000 LKD 8UC7 00C2 0000 1x6 12.5 215 2500 2.80 0.78 LKD 8UB7 00C3 0000 LKD 8UA2 00C3 0000 LKD 8UA5 00C3 0000 LKD 8UA7 00C3 0000 LKD 8UC7 00C3 0000 1x8 12.5 215 2500 2.80 0.78 LKD 8UB7 00C4 0000 LKD 8UA2 00C4 0000 LKD 8UA5 00C4 0000 LKD 8UA7 00C4 0000 LKD 8UC7 00C4 0000 1x10 12.5 215 2500 2.80 0.78 LKD 8UB7 00C5 0000 LKD 8UA2 00C5 0000 LKD 8UA5 00C5 0000 LKD 8UA7 00C5 0000 LKD 8UC7 00C5 0000 1x12 12.5 215 2500 2.80 0.78 LKD 8UB7 00C6 0000 LKD 8UA2 00C6 0000 LKD 8UA5 00C6 0000 LKD 8UA7 00C6 0000 LKD 8UC7 00C6 0000 1x16 12.5 215 2500 2.80 0.78 LKD 8UB7 00C7 0000 LKD 8UA2 00C7 0000 LKD 8UA5 00C7 0000 LKD 8UA7 00C7 0000 LKD 8UC7 00C7 0000 1x20 12.5 215 2500 2.80 0.78 LKD 8UB7 00C8 0000 LKD 8UA2 00C8 0000 LKD 8UA5 00C8 0000 LKD 8UA7 00C8 0000 LKD 8UC7 00C8 0000 1x24 12.5 215 2500 2.80 0.78 LKD 8UB7 00C9 0000 LKD 8UA2 00C9 0000 LKD 8UA5 00C9 0000 LKD 8UA7 00C9 0000 LKD 8UC7 00C9 0000 www.leoni-infrastructure-datacom.com GigaLine® FO data cables Loose tube, gel-filled 176 GigaLine® Outdoor cable, central 1750 N Type KL-A-DQ(ZN)B2Y 1xn G/E Outer sheath Loose tube, gel-filled Strain relief and rodent protection Description Thermal characteristics Outdoor cable for direct installation in the ground, in conduits Transport/storage –25 °C up to +70 °C and where there is a risk of rodent damage in MAN (city Installation –5 °C up to +50 °C networks) and LAN (campus/backbone). Suitable for structured Operating temperature –25 °C up to +60 °C cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edition). In keeping with the fiber type ideal for all applications from Mechanical characteristics Classes OF 300 to OF 10000. Easy to install thanks to grease- Min. bending radius free, dry cable core. Suitable for splicing. Max. crush strength Installation indoors, in conduits, on covered cable trays, static 15 x overall diameter dynamic 20 x overall diameter long-term 1500 N/dm short-term 2500 N/dm in cable ducts or directly in the ground. Mechanical pulling in with winches is only permitted in conjunction with force measuring devices with a logging feature. Fire performance Halogen free IEC 60754-1 Construction Further characteristics: Central filled loose tube with up to 24 fibers Longitudinal watertightness IEC 60794-1-2 F5 Fiber colour code acc. to IEC 60304 Impact resistance IEC 60794-1-2 E4 Loose tube colour: Yellow (E9/125), green (G50/125), blue (G62.5/125) Cable bending IEC 60794-1-2 E11 Strain relief Non-metallic (glass rovings) Cable sheath Resistant to PE, UV rays Sheath colour ● Black Fiber number Overall diam. approx. Weight approx. Max. strain relief Fire load approx. mm kg/km N MJ/m kWh/m Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 1x2 7.4 39 1750 1.21 0.34 LKD 8AB7 00A1 0000 LKD 8AA2 00A1 0000 LKD 8AA5 00A1 0000 LKD 8AA7 00A1 0000 LKD 8AC7 00A1 0000 1x4 7.4 39 1750 1.21 0.34 LKD 8AB7 00A2 0000 LKD 8AA2 00A2 0000 LKD 8AA5 00A2 0000 LKD 8AA7 00A2 0000 LKD 8AC7 00A2 0000 1x6 7.4 39 1750 1.21 0.34 LKD 8AB7 00A3 0000 LKD 8AA2 00A3 0000 LKD 8AA5 00A3 0000 LKD 8AA7 00A3 0000 LKD 8AC7 00A3 0000 1x8 7.4 39 1750 1.21 0.34 LKD 8AB7 00A4 0000 LKD 8AA2 00A4 0000 LKD 8AA5 00A4 0000 LKD 8AA7 00A4 0000 LKD 8AC7 00A4 0000 1x10 7.4 39 1750 1.21 0.34 LKD 8AB7 00A5 0000 LKD 8AA2 00A5 0000 LKD 8AA5 00A5 0000 LKD 8AA7 00A5 0000 LKD 8AC7 00A5 0000 1x12 7.4 39 1750 1.21 0.34 LKD 8AB7 00A6 0000 LKD 8AA2 00A6 0000 LKD 8AA5 00A6 0000 LKD 8AA7 00A6 0000 LKD 8AC7 00A6 0000 1x16 7.8 45 1750 1.39 0.39 LKD 8AB7 00A7 0000 LKD 8AA2 00A7 0000 LKD 8AA5 00A7 0000 LKD 8AA7 00A7 0000 LKD 8AC7 00A7 0000 1x20 7.8 45 1750 1.39 0.39 LKD 8AB7 00A8 0000 LKD 8AA2 00A8 0000 LKD 8AA5 00A8 0000 LKD 8AA7 00A8 0000 LKD 8AC7 00A8 0000 1x24 7.8 45 1750 1.39 0.39 LKD 8AB7 00A9 0000 LKD 8AA2 00A9 0000 LKD 8AA5 00A9 0000 LKD 8AA7 00A9 0000 LKD 8AC7 00A9 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 177 GigaLine® Outdoor cable, stranded 4000 N Type KL-A-DQ(ZN)B2Y nxm G/E Outer sheath Water-absorbent fleece Loose tube, gel-filled Strain relief GFR central strength Description Thermal characteristics Outdoor cable for direct installation in the ground, in conduits Transport/storage –40 °C up to +70 °C and where there is a risk of rodent damage in MAN (city Installation –10 °C up to +50 °C networks) and LAN (campus/backbone). Suitable for structured Operating temperature –40 °C up to +60 °C cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edition). In keeping with the fiber type ideal for all applications from Mechanical characteristics Classes OF 300 to OF 10000. Easy to install thanks to grease- Min. bending radius free, dry cable core. Suitable for splicing. Max. crush strength Installation indoors, in conduits, on covered cable trays, in static 15 x overall diameter dynamic 20 x overall diameter long-term 3000 N/dm short-term 4000 N/dm cable ducts or directly in the ground. Mechanical pulling in with winches is only permitted in conjunction with force measuring devices with a logging feature. Fire performance Halogen free IEC 60754-1 Construction Further characteristics: Stranded filled loose tube diameter 2.4 mm with up to 12 fibers Longitudinal watertightness IEC 60794-1-2 F5 Fiber colour code acc. to IEC 60304 Impact resistance IEC 60794-1-2 E4 Loose tube colour: Counting wire red, counting direction wire Cable bending IEC 60794-1-2 E11 white, yellow (E9/125), green (G50/125), blue (G62.5/125) Twisting Loose tubes and if applicable dummy elements around central strength member Strain relief Non-metallic (glass rovings) Cable sheath Resistant to PE, UV rays Sheath colour ● Black Overall diam. Fiber approx. number mm Weight approx. Max. strain relief Fire load approx. kg/km N MJ/m kWh/m 115 4000 2x12 11.5 4.10 Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9...10/125 1.14 LKD 8AB7 0K06 0000 LKD 8AA2 0K06 0000 LKD 8AA5 0K06 0000 LKD 8AA7 0K06 0000 LKD 8AC7 0K06 0000 LKD 8AB7 0K08 0000 LKD 8AA2 0K08 0000 LKD 8AA5 0K08 0000 LKD 8AA7 0K08 0000 LKD 8AC7 0K08 0000 4x12 11.5 115 4000 4.10 1.14 8x12 13.7 165 4000 4.96 1.38 LKD 8AB7 0K11 0000 LKD 8AA2 0K11 0000 LKD 8AA5 0K11 0000 LKD 8AA7 0K11 0000 LKD 8AC7 0K11 0000 12x12 17.0 230 4000 6.19 1.72 LKD 8AB7 0K13 0000 LKD 8AA2 0K13 0000 LKD 8AA5 0K13 0000 LKD 8AA7 0K13 0000 LKD 8AC7 0K13 0000 Other types on request www.leoni-infrastructure-datacom.com GigaLine® FO data cables member 178 GigaLine® Outdoor cable, central 1750 N Type KL-A-DQ(ZN)2Y(SR)2Y 1xn G/E Outer sheath Corrugated steel cladding Inner sheath Loose tube, gel-filled Strain relief Description Thermal characteristics Outdoor cable for direct installation in the ground, in conduits Transport/storage –25 °C up to +70 °C and where there is an increased risk of rodent damage in Installation – 5 °C up to +50 °C MAN (city networks) and LAN (campus/backbone). Suitable Operating temperature –25 °C up to +60 °C for structured cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edition). In keeping with the fiber type ideal for all Mechanical characteristics applications from Classes OF 300 to OF 10000. Easy to install Min. bending radius thanks to grease-free, dry cable core. Suitable for splicing. Max. crush strength Installation outdoors in conduits, on covered cable trays. static 15 x overall diameter dynamic 20 x overall diameter long-term 2500 N/dm short-term 3500 N/dm Mechanical pulling in with winches is only permitted in conjunction with force measuring devices with a logging feature. Fire performance Halogen free IEC 60754-1 Construction Central filled loose tube with up to 24 fibers Further characteristics: Fiber colour code acc. to IEC 60304 Longitudinal watertightness IEC 60794-1-2 F5 Strain relief Non-metallic (glass rovings) Impact resistance IEC 60794-1-2 E4 Inner sheath PE Cable bending IEC 60794-1-2 E11 Armouring Corrugated steel cladding as highly effective rodent protection Outer sheath Resistant to PE, UV rays Sheath colour ● Black Fiber number Overall diam. approx. Weight approx. Max. strain relief Fire load approx. mm kg/km N MJ/m kWh/m Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 1x2 11.0 119 1750 3.01 1.08 LKD 8AB7 00L1 0000 LKD 8AA2 00L1 0000 LKD 8AA5 00L1 0000 LKD 8AA7 00L1 0000 LKD 8AC7 00L1 0000 1x4 11.0 119 1750 3.01 1.08 LKD 8AB7 00L2 0000 LKD 8AA2 00L2 0000 LKD 8AA5 00L2 0000 LKD 8AA7 00L2 0000 LKD 8AC7 00L2 0000 1x6 11.0 119 1750 3.01 1.08 LKD 8AB7 00L3 0000 LKD 8AA2 00L3 0000 LKD 8AA5 00L3 0000 LKD 8AA7 00L3 0000 LKD 8AC7 00L3 0000 1x8 11.0 119 1750 3.01 1.08 LKD 8AB7 00L4 0000 LKD 8AA2 00L4 0000 LKD 8AA5 00L4 0000 LKD 8AA7 00L4 0000 LKD 8AC7 00L4 0000 1x10 11.0 119 1750 3.01 1.08 LKD 8AB7 00L5 0000 LKD 8AA2 00L5 0000 LKD 8AA5 00L5 0000 LKD 8AA7 00L5 0000 LKD 8AC7 00L5 0000 1x12 11.0 119 1750 3.01 1.08 LKD 8AB7 00L6 0000 LKD 8AA2 00L6 0000 LKD 8AA5 00L6 0000 LKD 8AA7 00L6 0000 LKD 8AC7 00L6 0000 1x16 11.6 127 1750 3.30 1.19 LKD 8AB7 00L7 0000 LKD 8AA2 00L7 0000 LKD 8AA5 00L7 0000 LKD 8AA7 00L7 0000 LKD 8AC7 00L7 0000 1x20 11.6 127 1750 3.30 1.19 LKD 8AB7 00L8 0000 LKD 8AA2 00L8 0000 LKD 8AA5 00L8 0000 LKD 8AA7 00L8 0000 LKD 8AC7 00L8 0000 1x24 11.6 127 1750 3.30 1.19 LKD 8AB7 00L9 0000 LKD 8AA2 00L9 0000 LKD 8AA5 00L9 0000 LKD 8AA7 00L9 0000 LKD 8AC7 00L9 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 179 GigaLine® Outdoor cable, stranded 4000 N Type KL-A-DQ(ZN)2Y(SR)2Y nxm G/E Outer sheath Corrugated steel cladding Inner sheath Water-absorbent fleece Loose tube, gel-filled Strain relief GFR central strength Description Thermal characteristics Outdoor cable for direct installation in the ground, in conduits Transport/storage –25 °C up to +70 °C and where there is an increased risk of rodent damage in MAN Installation –5 °C up to +50 °C (city networks) and LAN (campus/backbone). Suitable for use Operating temperature –25 °C up to +60 °C in structured cabling acc. to ISO/IEC 11801 and EN 50173 (2nd edition). In keeping with the fiber type ideal for all applications Mechanical characteristics from Classes OF 300 to OF 10000. Easy to install thanks to Min. bending radius grease-free, dry cable core. Suitable for splicing. Installation outdoors, in conduits, on covered cable trays Max. crush strength or directly in the ground. Mechanical pulling in with winches is only permitted in conjunction with force measuring devices with a logging feature. static 15 x overall diameter dynamic 20 x overall diameter long-term 3000 N/dm short-term 5000 N/dm Fire performance Halogen free IEC 60754-1 Construction Further characteristics: Stranded filled loose tube diameter 2.4 mm with up to 12 fibers Longitudinal watertightness IEC 60794-1-2 F5 Fiber colour code acc. to IEC 60304 Loose tube colour: Counting wire red, counting direction wire white, yellow (E9/125), green (G50/125), blue (G62.5/125) Twisting Loose tubes and if applicable dummy elements around central strength member Strain relief Non-metallic (glass rovings) Inner sheath PE, colour ● Black Impact resistance IEC 60794-1-2 E4 Cable bending IEC 60794-1-2 E11 Armouring Corrugated steel cladding as highly effective rodent protection Outer sheath Resistant to PE, UV rays Sheath colour ● Black Overall diam. Fiber approx. number mm Weight approx. Max. strain relief Fire load approx. kg/km N MJ/m kWh/m 285 4000 10.62 2x12 17.5 Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 2.95 LKD 8AB7 0A06 0000 LKD 8AA2 0A06 0000 LKD 8AA5 0A06 0000 LKD 8AA7 0A06 0000 LKD 8AC7 0A06 0000 LKD 8AB7 0A08 0000 LKD 8AA2 0A08 0000 LKD 8AA5 0A08 0000 LKD 8AA7 0A08 0000 LKD 8AC7 0A08 0000 4x12 17.5 285 4000 10.62 2.95 8x12 19.6 345 4000 12.24 3.40 LKD 8AB7 0A11 0000 LKD 8AA2 0A11 0000 LKD 8AA5 0A11 0000 LKD 8AA7 0A11 0000 LKD 8AC7 0A11 0000 12x12 21.5 400 4000 13.80 3.80 LKD 8AB7 0A13 0000 LKD 8AA2 0A13 0000 LKD 8AA5 0A13 0000 LKD 8AA7 0A13 0000 LKD 8AC7 0A13 0000 Other types on request www.leoni-infrastructure-datacom.com GigaLine® FO data cables member 180 GigaLine® Outdoor cable, stranded with sheath 4,000 N Type KL-A-DF(ZN)(L)2Y nxm G/E Outer sheath Aluminium tape Loose tube, gel-filled Water-blocking gel filling Strain relief GFR central strength member Description Thermal characteristics Water-blocking gel-filled longitudinally and transversely Transport/storage watertight outdoor cable for installation directly in the ground, Installation –5 °C up to +50 °C in conduits and where there is a risk of rodent damage in Operating temperature –40 °C up to +60 °C –40 °C up to +70 °C MAN (city networks) and LAN (campus/backbone). Suitable for use in structured cabling acc. to ISO/IEC 11801 and EN Mechanical characteristics 50173 (2nd edition). In keeping with the fiber type ideal for all Min. bending radius applications from Classes OF 300 to OF 10000. Suitable for splicing. Installation indoors and outdoors in conduits, on covered cable trays or directly in the ground. Mechanical pulling in with winches Max. crush strength is only permitted in conjunction with force measuring devices with a logging feature. static 15 x overall diameter dynamic 20 x overall diameter long-term 1500 N/dm short-term 3000 N/dm Fire performance Halogen free IEC 60754-1 Construction Stranded filled loose tube diameter 2.4 mm with up to 12 fibers Further characteristics: Fiber colour code acc. to IEC 60304 Longitudinal watertightness IEC 60794-1-2 F5 Loose tube colour: Counting wire red, counting direction wire Impact resistance IEC 60794-1-2 E4 white, yellow (E9/125), green (G50/125), blue (G62,5/125) Cable bending IEC 60794-1-2 E11 Twisting Loose tubes and if applicable dummy elements around central strength member Filling Water-blocking gel filling in twist cavities of the cable core Strain relief Non-metallic (glass rovings) Outer sheath Aluminium sheath, resistant to UV rays (aluminium tape with PE sheath) Sheath colour ● Black Overall diam. Fiber approx. number mm Weight approx. Max. strain relief Fire load approx. kg/km N MJ/m kWh/m 140 4000 2x12 12.1 Order no. OM1e G62.5/125 OM2e G50/125 OM3 G50/125 OM4 G50/125 OS2 E9…10/125 4.97 1.38 LKD 8AB7 0406 0000 LKD 8AA2 0406 0000 LKD 8AA5 0406 0000 LKD 8AA7 0A06 0000 LKD 8AC7 0406 0000 LKD 8AB7 0408 0000 LKD 8AA2 0408 0000 LKD 8AA5 0408 0000 LKD 8AA7 0A08 0000 LKD 8AC7 0408 0000 4x12 12.1 140 4000 4.97 1.38 8x12 14.4 200 4000 5.87 1.63 LKD 8AB7 0411 0000 LKD 8AA2 0411 0000 LKD 8AA5 0411 0000 LKD 8AA7 0A11 0000 LKD 8AC7 0411 0000 12x12 17.7 300 4000 7.24 2.01 LKD 8AB7 0413 0000 LKD 8AA2 0413 0000 LKD 8AA5 0413 0000 LKD 8AA7 0A13 0000 LKD 8AC7 0413 0000 Other types on request www.leoni-infrastructure-datacom.com Office Industry DataCenter GigaLine® FO data cables 181 www.leoni-infrastructure-datacom.com 182 GigaLine FO connectivity ® www.leoni-infrastructure-datacom.com Office Industry DataCenter 183 GigaLine® FO connectivity 182 GigaLine® FO cabling systems 184 GigaLine® trunk and splice boxes o dc Fiber optic trunk box o dc Fiber optic splice box • Telescopic splice box • Fixed splice box 188 189 190 192 GigaLine® Compact – fiber optic distribution system 195 o dc Compact fiber optic rack 196 o dc Compact fiber optic module For pre-assembled breakout cables 197 o dc Compact fiber optic module For splicing solutions 198 GigaLine® office and floor distributors o Fiber optic office and floor distributors • Size A for up to 4 splice cassettes • Size B for up to 24 splice cassettes GigaLine® Fiber-To-The-Desk (FTTD) wall outlets 201 202 203 205 o FTTD wall outlets • For surface mounting • For flush mounting o FTTD wall outlets • Cable reservoir • Splice tray for cable reservoir o o FTTD outlet for cable ducts 208 FTTD mounting bracket for cable ducts 209 o dc i Office DataCenter Industry www.leoni-infrastructure-datacom.com 206 207 GigaLine® FO connectivity 187 • Telescopic trunk box • Fixed trunk box 184 GigaLine® FO cabling systems High-performance components for building a fiber optic infrastructure GigaLine® is a perfectly coordinated system made up The GigaLine® system is determined by the application, required of components optimised for performance and quality. link length and transmission protocol. The interplay of high-quality fibers which far exceed the The table below shows the protocol-dependent attenuation standard and connectors with high-quality workmanship enable budget according to EN 50173-1 for the 10 Gigabit Ethernet maximum performance and range for the respective application protocol. From this is derived the number of possible (GbE/10 GbE). connections based on the overall link. The following harmonised The requirements for fibers and connectors differ depending on the field of application. OM1e OM2 OM2e OM3 OM4 components were taken into consideration when putting together the system: OS2 Industry SC, ST Office LC, SC DataCenter ■■ multimode fibers that far exceed the standard and have LC, MTP/MPO Campus Fiber optic cables (GigaLine®) with laser/dispersion-optimised appropriate performance reserves (for fiber specifications see LC, SC section on GigaLine® fiber optic data cables) The system components are optimised to meet the ■■ requirements for both distance and data rate. That is why LEONI Fiber optic connectors with low insertion losses and high return losses consistently uses its own j-fiber fibers (cables, pigtails, patch cords). Industry Office DataCenter Campus GigaLine® Compact Maximum transmission lengths for 10 Gigabit Ethernet system solutions. GigaLine® DClink GigaLine® trunk and splice boxes GigaLine® wall distributors GigaLine® wall outlets GigaLine® has components for every field of application. Max. link length* OM2e OM3 OM4 OS2 150 300 550 10,000 Attenuation budget** 1.8 dB 2.6 dB 2.6 dB 6.2 dB Max. fiber attenuation 0.37 dB 0.75 dB 1.37 dB 3.6 dB 6 8 6 12 LC, MTP/ MPO, SC LC, MTP/ MPO, SC LC, MTP/ MPO, SC LC, SC Number of possible connectors Recommended connectors * Based on 10 GbE ** All specifications are based on 850 nm or 1,310 nm www.leoni-infrastructure-datacom.com Office Office Industry DataCenter 185 Graph 1 shows the system reserves afforded by the high-quality Quality is our benchmark fibers and connectors in relation to EN 50173. Assembly of fiber optic connectors involves both adjustment of the fibers in the ferrule as well as time-consuming grinding and ■■ polishing. The aim here is to machine the connector so precisely Longer transmission lengths for certain applications by means of optimised processes that the insertion loss and (100 Mb/s, 1 GbE, 10 GbE, 40 GbE, 100 GbE) reflections are kept to a minimum. This is done by means of ■■ The option to insert more patch cords or splices PC polishing (PC = physical contact). Spherical polishing of the ■■ Additional attenuation caused by aging processes ferrule spring mounted in the connector housing produces can be curtailed a fiber/fiber transition at the end faces. In other words when Network extensions can be realised with ease and a certain two connectors are plugged into one coupling, the spring level of assurance within the link lengths pressure pushes out all the air between the mating fibers of ■■ both connectors. The glass/glass transition then has very low reflections and low attenuation. Distance/km To maximise the performance of a PC connector, the surface Attenuation-limited operation LEONI OM4 LEONI OM3 LEONI OM2e Standard OM3 Standard OM2 parameters of the connectors must be carefully checked during the polishing process. The interferometer is an indicatory measuring instrument for this. The overlaps of coherent light waves are used to measure the quality of optical surfaces (ferrule surfaces). Dispersion-limited operation The most important parameters are: ■■ Apex offset (offset between the highest point and the centre of the fiber) Bandwidth/MHz Graph 1: System reserves of GigaLine® 150, 300 and 550 relative to the standard ■■ Radius of the connector interface (fiber/ferrule) ■■ Fiber height (undercut, protrusion) These parameters are decisive for the long-term behaviour and therefore the quality of a fiber optic connector. Insertion loss of the connectors used in GigaLine® system components. Insertion loss typ. Return loss G62.5/125 OM1e 0.2 dB > 40 dB G50/125 OM2e 0.2 dB > 40 dB G50/125 OM3 0.2 dB > 40 dB G50/125 OM4 0.2 dB > 40 dB E9..10/125 OS2 0.2 dB > 50 dB E9..10/125 OS2 APC 0.2 dB > 70 dB Fiber type www.leoni-infrastructure-datacom.com GigaLine® FO connectivity Decisive advantages of these system reserves are: 186 www.leoni-infrastructure-datacom.com Office Industry DataCenter 187 GigaLine® Trunk and splice boxes Multifunctional housing technology, 19" GigaLine® trunk and splice boxes can be used in all areas of Your guarantee for quick and reliable installation: building data cabling. The construction of the components ■■ The box body is made from aluminium and therefore very light ensures speed and reliability during initial installation, ■■ The boxes are assembled ready to install maintenance and extension. ■■ The permissible bending radii as well as ease of installation are guaranteed even with high packing densities All boxes are pre-assembled ready to install and constructed so ■■ The telescopic version offers the advantage that all components are easily accessible for testing and maintenance work that two cables can be inserted via cable glands or two divider heads can be inserted from above. A breakout panel to which the cables can be secured using cable ties is available as an GigaLine® trunk and splice box: alternative. ■■ Boxes with one rack unit as fixed installation or telescopic Boxes with two rack units are always telescopic ■■ The front panel is made from galvanised steel panel and Light grey RAL 7035, powder coated ■■ One rack unit can be equipped with up to 24 x SC Duplex, 24 x LC Duplex, 24 x MT-RJ, 24 x E 2000, 24 x ST, 24 x FC couplings www.leoni-infrastructure-datacom.com GigaLine® FO connectivity version ■■ 188 GigaLine® Fiber optic trunk box Box 19"/1 RU, telescopic or fixed GigaLine® trunk box,  telescopic Description Configuration Telescopic fiber optic patch panel for pre-assembled trunk Equipment Available with up to 24 slots cables. Suitable for terminating up to 48 optical fibers. Couplings SC Duplex, FC-PC/FC-APC, ST E2000/E2000 HRL, MTRJ, LC Duplex Construction Box Aluminium, with dust protective cover Accessories (optional) telescopic and removable drawer, depth Breakout panel For securing cables using cable ties continuously adjustable by up to 50 mm Front panel and Galvanised steel panel, powder coated mounting bracket colour: Grey RAL 7035 Capacity Installation of up to 2 trunk cables Labelling Channel 1–12/1–24 (screen printing) Dimensions A/B coding with SC/ST/FC configuration Designation Order no. 19"/1 RU GigaLine® trunk box,  telescopic See table 44 mm x 483 mm x 220 mm (H x W x D) Breakout panel LKD 9D60 0000 0000 Approx. 1.7 kg Weight Singlemode Number of fibers 6 SC Duplex Met/Cer SC Duplex, blue Plastic/Cer LCD, blue Plastic/Cer E2000, blue Plastic/Cer E2000HRL, green Plastic/Cer LKD 9D32 A039 0000 LKD 9D32 A003 0000 LKD 9D32 A014 0000 LKD 9D32 A017 0000 LKD 9D32 A020 0000 12 LKD 9D32 A040 0000 LKD 9D32 A004 0000 LKD 9D32 A015 0000 LKD 9D32 A018 0000 LKD 9D32 A002 0000 24 LKD 9D32 A041 0000 LKD 9D32 A005 0000 LKD 9D32 A001 0000 LKD 9D32 A019 0000 LKD 9D32 A021 0000 48 LKD 9D32 A095 0000 LKD 9D32 A006 0000 LKD 9D32 A016 0000 SC Duplex, beige Plastic/PhBz LC Duplex, beige Plastic/PhBz LC Duplex, aqua Plastic/Cer LC Duplex, heather violet Plastic/Cer E2000, beige Plastic/Cer LKD 9D32 A022 0000 LKD 9D32 A032 0000 LKD 9D32 A178 0000 LKD 9D32 A181 0000 LKD 9D32 A036 0000 Multimode Number of fibers 6 12 LKD 9D32 A023 0000 LKD 9D32 A033 0000 LKD 9D32 A179 0000 LKD 9D32 A182 0000 LKD 9D32 A037 0000 24 LKD 9D32 A000 0000 LKD 9D32 A034 0000 LKD 9D32 A180 0000 LKD 9D32 A183 0000 LKD 9D32 A038 0000 48 LKD 9D32 A024 0000 LKD 9D32 A035 0000 LKD 9D32 A177 0000 LKD 9D32 A184 0000 Other configurations available on request www.leoni-infrastructure-datacom.com Office Industry DataCenter DataCenter 189 Description Configuration Fiber optic patch box for pre-assembled trunk cables. Suitable Equipment Available with up to 24 slots for terminating up to 48 optical fibers. Couplings SC Duplex, FC-PC/FC-APC, ST E2000/E2000 HRL, MTRJ, LC Duplex Construction Box Aluminium, with dust protective cover Accessories (optional) Front panel Galvanised sheet panel, powder coated Breakout panel using cable ties colour: Grey RAL 7035 Capacity Installation of up to 2 trunk cables Labelling Channel 1–12/1–24 (screen printing) For securing cables A/B coding with SC/ST/FC configuration Dimensions 19"/1 RU Weight 44 mm x 483 mm x 220 mm (H x W x D) Designation Order no. Approx. 1.4 kg GigaLine® Smart trunk, fixed See table Breakout panel LKD 9D60 0000 0000 Singlemode Number of fibers 6 SC Duplex Met/Cer SC Duplex, blue Plastic/Cer LKD 9D42 A034 0000 LKD 9D42 A003 0000 LCD, blue Plastic/Cer LKD 9D42 A012 0000 E2000, blue Plastic/Cer E2000HRL, green Plastic/Cer LKD 9D42 A014 0000 LKD 9D42 A017 0000 12 LKD 9D42 A035 0000 LKD 9D42 A004 0000 LKD 9D42 A013 0000 LKD 9D42 A015 0000 LKD 9D42 A018 0000 24 LKD 9D42 A036 0000 LKD 9D42 A005 0000 LKD 9D42 A033 0000 LKD 9D42 A016 0000 LKD 9D42 A002 0000 48 LKD 9D42 A047 0000 LKD 9D42 AXXX 0000 LKD 9D42 A001 0000 SC Duplex, beige Plastic/PhBz LC Duplex, beige Plastic/PhBz LC Duplex, aqua Plastic/Cer LC Duplex, heather violet Plastic/Cer E2000, beige Plastic/Cer LKD 9D42 A019 0000 LKD 9D42 A027 0000 LKD 9D42 A113 0000 LKD 9D42 A117 0000 LKD 9D42 A030 0000 Multimode Number of fibers 6 12 LKD 9D42 A020 0000 LKD 9D42 A028 0000 LKD 9D42 A114 0000 LKD 9D42 A118 0000 LKD 9D42 A031 0000 24 LKD 9D42 A000 0000 LKD 9D42 A029 0000 LKD 9D42 A115 0000 LKD 9D42 A119 0000 LKD 9D42 A032 0000 48 LKD 9D42 A046 0000 LKD 9D42 A050 0000 LKD 9D42 A116 0000 LKD 9D42 A120 0000 Other configurations available on request www.leoni-infrastructure-datacom.com GigaLine® FO connectivity GigaLine® trunk box,  fixed 190 GigaLine® Fiber optic splice box Box 19"/1 RU, telescopic GigaLine® splice box,  telescopic Description Optical characteristics Telescopic fiber optic patch panel for up to 48 optical fibers. For Insertion loss typ. For all fiber types 0.2 dB Return loss typ. G62.5/125 OM1e > 40 dB Aluminium, with dust protective cover, G50/125 OM2e > 40 dB telescopic and removable drawer, depth G50/125 OM3 > 40 dB continuously adjustable by up to 50 mm G50/125 OM4 > 40 dB Galvanised steel panel, powder coated E9..10/125 OS2 > 50 dB mounting bracket colour: Grey RAL 7035 E9..10/125 OS2 APC > 70 dB Pigtails Pigtails ready for splicing and plugged in Configuration (colours acc. to DIN IEC 60304) Equipment Available with up to 24 slots Channel 1–12/1–24 (screen printing) Couplings SC Duplex, FC-PC/FC-APC, ST, terminating fiber optic transmission links with pigtails. Construction Box Front panel and Labelling A/B coding with SC/ST/FC configuration Dimensions Weight E2000/E2000 HRL, MTRJ, LC Duplex 19"/1 RU 44 mm x 483 mm x 220 mm (H x W x D) Accessories Approx. 1.8 kg 1 x M20 cable gland Splice cassette Crimp splice protective holder Accessories (optional) Breakout panel Designation Order no. GigaLine® splice box, telescopic See table Breakout panel LKD 9D60 0000 0000 For securing cables using cable ties www.leoni-infrastructure-datacom.com Office Industry DataCenter DataCenter 191 Singlemode OS2 E9..10/125 Number of fibers SC Duplex Met/Cer SC Duplex, blue Plastic/Cer LCD, blue Plastic/Cer E2000, blue Plastic/Cer E2000HRL, green Plastic/Cer 6 LKD 9D31 A093 0000 LKD 9D31 A003 0000 LKD 9D31 A014 0000 LKD 9D31 A018 0000 LKD 9D31 A021 0000 12 LKD 9D31 A094 0000 LKD 9D31 A004 0000 LKD 9D31 A015 0000 LKD 9D31 A019 0000 LKD 9D31 A022 0000 LKD 9D31 A020 0000 LKD 9D31 A023 0000 24 LKD 9D31 A002 0000 LKD 9D31 A005 0000 LKD 9D31 A016 0000 48 LKD 9D31 A096 0000 LKD 9D31 A006 0000 LKD 9D31 A017 0000 Number of fibers SC Duplex, beige Plastic/PhBz LCD, beige Plastic/PhBz LKD 9D31 A089 0000 6 LKD 9D31 A078 0000 12 LKD 9D31 A079 0000 LKD 9D31 A090 0000 24 LKD 9D31 A080 0000 LKD 9D31 A091 0000 48 LKD 9D31 A081 0000 LKD 9D31 A092 0000 Multimode OM2e G50/125 Number of fibers 6 SC Duplex, beige Met/Cer SC Duplex, beige Plastic/PhBz LCD, beige Plastic/PhBz E2000, beige Plastic/Cer LKD 9D31 AXXX 0000 LKD 9D31 A024 0000 LKD 9D31 A035 0000 LKD 9D31 A039 0000 12 LKD 9D31 AXXX 0000 LKD 9D31 A025 0000 LKD 9D31 A036 0000 LKD 9D31 A040 0000 24 LKD 9D31 A180 0000 LKD 9D31 A026 0000 LKD 9D31 A037 0000 LKD 9D31 A041 0000 48 LKD 9D31 AXXX 0000 LKD 9D31 A027 0000 LKD 9D31 A038 0000 SC Duplex, beige Plastic/PhBz LCD, aqua Plastic/Cer Multimode OM3 G50/125 Number of fibers SC Duplex, beige Met/Cer E2000, beige Plastic/Cer 6 LKD 9D31 AXXX 0000 LKD 9D31 A042 0000 LKD 9D31 A198 0000 LKD 9D31 A057 0000 12 LKD 9D31 A139 0000 LKD 9D31 A043 0000 LKD 9D31 A199 0000 LKD 9D31 A058 0000 24 LKD 9D31 A000 0000 LKD 9D31 A044 0000 LKD 9D31 A186 0000 LKD 9D31 A059 0000 48 LKD 9D31 A001 0000 LKD 9D31 A045 0000 LKD 9D31A281 0000 SC Duplex, beige Plastic/PhBz LCD, heather violet Plastic/Cer E2000, beige Plastic/Cer Multimode OM4 G50/125 Number of fibers SC Duplex, beige Met/Cer 6 LKD 9D31 AXXX 0000 LKD 9D31 A060 0000 LKD 9D31 A200 0000 LKD 9D31 A075 0000 12 LKD 9D31 AXXX 0000 LKD 9D31 A061 0000 LKD 9D31 A295 0000 LKD 9D31 A076 0000 24 LKD 9D31 A229 0000 LKD 9D31 A062 0000 LKD 9D31 AXXX 0000 LKD 9D31 A077 0000 48 LKD 9D31 A230 0000 LKD 9D31 A063 0000 LKD 9D31 AXXX 0000 Other configurations available on request www.leoni-infrastructure-datacom.com GigaLine® FO connectivity Multimode OM1e G62.5/125 192 GigaLine® Fiber optic splice box Box 19"/1 RU, fixed GigaLine® splice box,  fixed Description Optical characteristics Fiber optic patch panel, for up to 48 optical fibers. Insertion loss typ. For all fiber types 0.2 dB Return loss typ. G62.5/125 OM1e > 40 dB OM2e > 40 dB For terminating fiber optic transmission links with pigtails. Construction Box Aluminium with dust protective cover G50/125 Front panel Galvanised steel panel, colour: Grey RAL 7035 G50/125 OM3 > 40 dB Pigtails ready for splicing and plugged in G50/125 OM4 > 40 dB (colours acc. to DIN IEC 60304) E9..10/125 OS2 > 50 dB Channel 1–12/1–24 (screen printing) E9..10/125 OS2 APC > 70 dB Pigtails Labelling A/B coding with SC/ST/FC configuration Dimensions Weight 19"/1 RU Configuration 44 mm x 483 mm x 220 mm (H x W x D) Equipment Available with up to 24 slots Approx. 1.5 kg Couplings SC Duplex/SC Duplex, FC-PC, FC-PC(HRL) (SM), ST/ST, E2000/E2000, E2000HRL/ E2000HRL (SM), MT-RJ/MT-RJ (MM), LC Duplex Accessories 1 x M20 cable gland Splice cassette Crimp splice protective holder Accessories (optional) Breakout panel Designation Order no. GigaLine® splice box, fixed See table Breakout panel LKD 9D60 0000 0000 For securing cables using cable ties www.leoni-infrastructure-datacom.com Office Industry DataCenter DataCenter 193 Singlemode OS2 E9..10/125 Number of fibers SC Duplex, blue Met/Cer SC Duplex, blue Plastic/PhBz E2000, blue Plastic/Cer E2000HRL, green Plastic/Cer LKD 9D41 A021 0000 6 LKD 9D41 A100 0000 LKD 9D41 AXXX 0000 LKD 9D41 A018 0000 12 LKD 9D41 A080 0000 LKD 9D41 AXXX 0000 LKD 9D41 A019 0000 LKD 9D41 A022 0000 24 LKD 9D41 A081 0000 LKD 9D41 AXXX 0000 LKD 9D41 A020 0000 LKD 9D41 A023 0000 48 LKD 9D41 A159 0000 LKD 9D41 AXXX 0000 Number of fibers SC Duplex, beige Met/Cer SC Duplex, beige Plastic/PhBz LCD, beige Plastic/PhBz E2000, beige Plastic/Cer LKD 9D41 AXXX 0000 6 LKD 9D41 AXXX 0000 LKD 9D41 A065 0000 LKD 9D41 A074 0000 12 LKD 9D41 AXXX 0000 LKD 9D41 A066 0000 LKD 9D41 A075 0000 LKD 9D41 AXXX 0000 24 LKD 9D41 AXXX 0000 LKD 9D41 A067 0000 LKD 9D41 A076 0000 LKD 9D41 AXXX 0000 48 LKD 9D41 AXXX 0000 LKD 9D41 AXXX 0000 Multimode OM2e G50/125 Number of fibers SC Duplex, beige Met/Cer SC Duplex, beige Plastic/PhBz LCD, beige Plastic/PhBz E2000, beige Plastic/Cer 6 LKD 9D41 AXXX 0000 LKD 9D41 A024 0000 LKD 9D41 A035 0000 LKD 9D41 A039 0000 12 LKD 9D41 A079 0000 LKD 9D41 A025 0000 LKD 9D41 A036 0000 LKD 9D41 A040 0000 24 LKD 9D41 A169 0000 LKD 9D41 A026 0000 LKD 9D41 A037 0000 LKD 9D41 A041 0000 48 LKD 9D41 AXXX 0000 LKD 9D41 A147 0000 LKD 9D41 A166 0000 SC Duplex, beige Met/Cer SC Duplex, beige Plastic/PhBz LCD, aqua Plastic/Cer E2000, beige Plastic/Cer Multimode OM3 G50/125 Number of fibers 6 LKD 9D41 AXXX 0000 LKD 9D41 A002 0000 LKD 9D41 A229 0000 LKD 9D41 A047 0000 12 LKD 9D41 A121 0000 LKD 9D41 A006 0000 LKD 9D41 A230 0000 LKD 9D41 A048 0000 24 LKD 9D41 A077 0000 LKD 9D41 A010 0000 LKD 9D41 A231 0000 LKD 9D41 A049 0000 48 LKD 9D41 AXXX 0000 LKD 9D41 AXXX 0000 LKD 9D41 A232 0000 SC Duplex, beige Met/Cer SC Duplex, beige Plastic/PhBz LCD, heather violet Plastic/Cer E2000, beige Plastic/Cer Multimode OM4 G50/125 Number of fibers 6 LKD 9D41 AXXX 0000 LKD 9D41 A050 0000 LKD 9D41 AXXX 0000 LKD 9D41 A062 0000 12 LKD 9D41 AXXX 0000 LKD 9D41 A051 0000 LKD 9D41 A238 0000 LKD 9D41 A063 0000 24 LKD 9D41 AXXX 0000 LKD 9D41 A052 0000 LKD 9D41 A233 0000 LKD 9D41 A064 0000 48 LKD 9D41 AXXX 0000 LKD 9D41 AXXX 0000 LKD 9D41 A234 0000 Other configurations available on request www.leoni-infrastructure-datacom.com GigaLine® FO connectivity Multimode OM1e G62.5/125 194 www.leoni-infrastructure-datacom.com Office Industry DataCenter DataCenter 195 GigaLine® Compact – fiber optic distribution system For maximum packing density and flexibility GigaLine® Compact is a user-friendly fiber optic distribution system that can be configured with up to 144 fibers with conventional couplings such as SC, ST, E 2000 and with 288 fibers with LC Duplex couplings. The system combines compactness with optimum fiber optic management. GigaLine® Compact is ideal for applications where GigaLine® FO connectivity space is tight and maximum flexibility is required. GigaLine® Compact rack with excess-length drawer 3+1 RU ■■ Width: 19"/84 HP ■■ Height 4 RU (3 RU rack + 1 RU excess-length drawer) ■■ Can be configured with up to 12 modules ■■ Excess-length drawer can be pulled out towards the rear, for holding loose tube reserves and securing the fiber optic cables, alternatively up to 6 pre-assembled trunk cables with up to 48 fibers can be secured using cable glands ■■ Management panel for patch cord routing and adherence to the bending radii GigaLine® rack with excess-length drawer 3+1 RU GigaLine® Compact module 3 RU/7 HP ■■ For up to 24 fibers ■■ Available with up to 12 couplings ■■ Configured with SC Duplex, ST, E2000, FC-PC, MT-RJ or LC Duplex couplings ■■ Front panel: Aluminium, with mounting screws ■■ Including splicing cassette and excess-length cassette ■■ Buffered fiber pigtails are inserted, stripped and coloured (primary and secondary coating) acc. to the DIN IEC 60304 colour code ready for splicing for fast and secure installation ■■ Fiber qualities: OM1e, OM2e, OM3, OM4 and OS2 ■■ The couplings can be retrofitted at any time GigaLine® Compact module 3 RU, 7 HP www.leoni-infrastructure-datacom.com 196 GigaLine® Compact fiber optic rack with mounted excess-length drawer 3+1 RU Loose tube guide plate GigaLine® Compact rack Description Accessories (optional) Rack with 84 HP. The excess-length drawer for the loose tubes Loose tube guide To protect the loose tubes on the rear, can be pulled out to the rear. Max. 6 trunk cables with 48 fibers plate especially in open racks each can be inserted from above or up to 12 loose tube cables with max. 288 fibers can be inserted from the front. Dummy front panel To close off unused 7 HP module slots Construction Box Aluminium with permanently installed runners for the built-in modules Excess-length For clear organisation of the drawer loose tube reserves and securing, can be pulled out to the rear 19"/4 RU Dimensions 176 mm x 483 mm x 295 mm (H x W x D) Accessories 1 x M20 cable gland Rack – rear view 5 x patch cord routing Designation Order no. GigaLine® Compact rack LKD 9D50 0000 0000 Loose tube guide plate LKD 9D50 0005 0000 Dummy front panel 7 HP LKD 9D50 0004 0000 Rack for GigaLine® trunk cables – rear view www.leoni-infrastructure-datacom.com Office Industry DataCenter DataCenter 197 GigaLine® Compact fiber optic module Built-in module for pre-assembled breakout cables, 3 RU/7 HP Description Configuration Built-in module, available with 3, 6 and 12 slots. Couplings Including excess-length cassette. SC Duplex, ST, E2000, FC-PC, MT-RJ, LC Duplex, LC-Quad Construction Accessories Module rack Aluminium Labelling strips Front panel Aluminium, with mounting screws Cable ties Capacity For up to 24 fibers Dimensions 7 HP/1 RU 128 mm x 35 mm x 240 mm (H x W x D) Singlemode Number of fibers SC Duplex, blue Plastic/Cer LCD, blue Plastic/Cer E2000, blue Plastic/Cer 6 LKD 9D52 0000 0000 LKD 9D52 0008 0000 LKD 9D52 0011 0000 12 LKD 9D52 0001 0000 LKD 9D52 0009 0000 LKD 9D52 0012 0000 24 LKD 9D52 0010 0000 (LC-Quad) Multimode SC Duplex, beige Plastic/PhBz LC Duplex, beige Plastic/PhBz 6 LKD 9D52 0016 0000 LKD 9D52 0024 0000 LKD 9D52 0XXX 0000 LKD 9D52 0XXX 0000 12 LKD 9D52 0017 0000 LKD 9D52 0025 0000 LKD 9D52 0XXX 0000 LKD 9D52 0XXX 0000 LKD 9D52 0026 0000 (LC-Quad) LKD 9D52 0036 0000 (LC-Quad) LKD 9D52 0037 0000 (LC-Quad) Number of fibers 24 Further connectors available on request www.leoni-infrastructure-datacom.com LC Duplex, aqua Plastic/Cer LC Duplex, heather violet Plastic/Cer GigaLine® FO connectivity GigaLine® Compact trunk module 198 GigaLine® Compact fiber optic module Built-in module for splicing solutions GigaLine® Compact splice module Description Optical characteristics Built-in module, available with 3, 6 and 12 slots. Insertion loss typ For all fiber types 0.2 dB (primary and secondary coating) acc. to the DIN IEC 60304 G62.5/125 OM1e > 40 dB colour code ready for splicing for fast and secure installation. G50/125 OM2e > 40 dB G50/125 OM3 > 40 dB G50/125 OM4 > 40 dB Including splice cassette and excess-length cassette. The buffered fiber pigtails are inserted, stripped and coloured Return loss typ. Construction Aluminium E9..10/125 OS2 > 50 dB Front panel Aluminium, with mounting screws E9..10/125 OS2 APC > 70 dB Pigtails Up to 24 pigtails ready for splicing and Module rack Dimensions plugged in (colours acc. to DIN IEC 60304) Configuration 7 HP/1 RU Couplings The couplings can be retrofitted at any time 128 mm x 35 mm x 240 mm (H x W x D) Accessories Labelling strips Cable ties for securing the loose tubes Crimp splice protective holder Protective tube for loose tubes 90 cm www.leoni-infrastructure-datacom.com Office Industry DataCenter DataCenter 199 Singlemode OS2e E9.. 10/125 Number of fibers SC Duplex, blue Met/Cer LC Duplex, blue Plastic/Cer E2000, blue Plastic/Cer 6 LKD 9D51 0003 0000 LKD 9D51 0010 0000 LKD 9D51 0014 0000 12 LKD 9D51 0036 0000 LKD 9D51 0011 0000 LKD 9D51 0015 0000 24 LKD 9D51 0012 0000 (LC-Quad) Multimode OM1e G62.5/125 Number of fibers SC Duplex Plastic/PhBz LC Duplex Plastic/PhBz 6 LKD 9D51 0071 0000 LKD 9D51 0077 0000 12 LKD 9D51 0072 0000 LKD 9D51 0078 0000 24 LKD 9D51 0079 0000 (LC-Quad) Number of fibers SC Duplex Plastic/PhBz LC Duplex Plastic/PhBz 6 LKD 9D51 0023 0000 LKD 9D51 0029 0000 12 LKD 9D51 0024 0000 LKD 9D51 0030 0000 24 LKD 9D51 0031 0000 (LC-Quad) Multimode OM3 G50/125 Number of fibers SC Duplex Plastic/PhBz LC Duplex, aqua Plastic/Cer 6 LKD 9D51 0039 0000 LKD 9D51 00XX 0000 12 LKD 9D51 0040 0000 24 LKD 9D51 00XX 0000 LKD 9D51 0092 0000 (LC-Quad) Multimode OM3e G50/125 Number of fibers SC Duplex Plastic/PhBz LC Duplex, heather violet Plastic/Cer 6 LKD 9D51 0055 0000 LKD 9D51 00XX 0000 12 LKD 9D51 0056 0000 24 Other configurations on request www.leoni-infrastructure-datacom.com LKD 9D51 XXXX 0000 LKD 9D51 0093 (LC-Quad) GigaLine® FO connectivity Multimode OM2e G50/125 200 www.leoni-infrastructure-datacom.com Office Industry DataCenter 201 GigaLine® Office and floor distributors Multifunctional housing for FTTD/FTTO cabling Network installations are increasingly being implemented GigaLine® stands for a high degree of flexibility: with disturbance-proof fiber optic systems technology ■■ The GigaLine® office and floor distributors can be optionally with future capabilities. This allows EMC problems as well equipped with splice cassettes and/or distributor plates for as different earthing potentials to be avoided for cabling holding fiber optical couplings reaching through whole buildings. ■■ When a fiber optic cabling system with a star structure is used ■■ Holds up to 288 fibers in a building, the long ranges involved make it possible to ■■ The buffered fiber pigtails are coloured acc. to the DIN IEC Later modifications to the components used are possible at any time 60304 colour code for fast and reliable installation dispense with active components on the individual floors. 19" The pigtail buffered fibers in the splice cassette are stripped and ready for splicing as the associated power supply are no longer necessary. ■■ The incoming and outgoing fiber optic cables are fixed to a strain relief strip in the housing The space-saving office and floor distributors are perfectly suited for the transitions from high-fiber backbone cables to ■■ The cable entries are sealed via brush strips or PG cable glands breakout cables for workplace cabling. They are easy to install ■■ Housings have one removable/lockable swing door and offer space-saving organisation and optimum protection ■■ Housing colour: Light grey RAL 7035 for fiber optic systems engineering. GigaLine® office and floor distributor ➔ Are tailored to the customer's requirements and supplied fully assembled ➔ Are available in 2 sizes Office 1 Office 4 Office 5 Office 2 Office 6 Office 3 Office 7 Basement www.leoni-infrastructure-datacom.com GigaLine® FO connectivity distributor cabinets and separate security areas (rooms) as well ■■ 202 GigaLine® Fiber optic office and floor distributor Wall distributor for up to 4 or 24 splice cassettes GigaLine® wall distributor  size A Application Dimensions Space-saving distributor cabinets for Fiber-To-The-Office or Size A 300 mm x 300 mm x 85 mm (H x W x D) Fiber-To-The-Desk cabling systems. Suitable for distributing up to 24 channels (48 fibers). Configuration Optionally only with couplings for pre-assembled trunks, Features as splice box or combined For up to 4 splice cassettes with a total of 48 fibers. The buffered fiber pigtails are inserted, stripped and coloured acc. to the DIN Accessories IEC 60304 colour code (primary and secondary coating) ready Up to 4 splice cassettes for splicing for fast and reliable installation. With crimp splice protective holder, buffered fiber strain relief and cover Construction ■■ Powder-coated steel panel, colour Light grey RAL 7035 ■■ Cable entry from above and below possible ■■ 4 cable entries either as M20/M25 or strip brush ■■ Door with lock or bolt ■■ Weight approx. 4 kg Up to 24 couplings: LCD, SCD or E2000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 203 Application Dimensions Space-saving distributor cabinets for Fiber-To-The-Office or Size B 600 mm x 425 mm x 220 mm (H x W x D) Fiber-To-The-Desk cabling systems. Suitable for distributing up to 144 channels (288 fibers). Configuration See distributor A Features For up to 24 splice cassettes for up to 288 fibers. The buffered Accessories fiber pigtails are inserted, stripped and coloured (primary and Up to 24 splice cassettes with crimp splice protective holder, secondary coating) acc. to the DIN IEC 60304 colour code ready buffered fiber strain relief and cover for splicing for fast and secure installation. or up to 96 ST or LCD couplings or up to 48 SCD couplings with the corresponding number Construction ■■ Powder-coated steel panel, colour Light grey RAL 7035 ■■ Cable entry from above and below possible ■■ 4 cable entries either as M20/M25 or strip brush ■■ Door with lock or bolt ■■ Weight approx. 7 kg www.leoni-infrastructure-datacom.com of splice cassettes GigaLine® FO connectivity GigaLine® wall distributor  size B 204 www.leoni-infrastructure-datacom.com Office Industry DataCenter 205 GigaLine® Fiber-To-The-Desk (FTTD) wall outlets Compact fiber optic connectivity – high performance, GigaLine® flush-mounted outlet immunity to disturbances, future capabilities The flush-mounted outlet can be installed in ducts or, Of course, the GigaLine® system also includes comprehensive as the name suggests, mounted flush. solutions for fiber-to-the-desk. Here it is possible to use a wide range of wall outlets with the corresponding installation Special features: materials for surface mounting and installation in ducts. ■■ As a result of a specific outlet design, bending never goes below ■■ Can be equipped with up to two duplex or four simplex couplings the fiber keeps its full functionality even in the long term: A defined bending radius for the fiber ensures the service life ■■ An effective strain relief for cables and pigtails and clean ■■ by the cable reservoir and the cable guide ■■ The outlet has a downward inclination of 10°. This ensures optimum protection against mechanical stress guidance within the outlet ensure minimum strain on the fiber and preservation of the physical characteristics ■■ The bending radius of the fiber of at least 30 mm is ensured ■■ The dimensions of the outlets are as small as possible The universal carrying frame is compatible with usual mounting cups ■■ All current connecting techniques are supported: ➔ Assembly of fiber optic plugs on site ➔ Use of pre-assembled cables ➔ Splicing of buffered fiber pigtails GigaLine® flush-mounted outlet Lebensdauer (Jahre) 10 000 100 25 Jahre 1 – 5 loops – 4 loops 0,01 – 3 loops – 2 loops – 1 loop 0,0001 10 15 20 25 Biegeradius (mm) www.leoni-infrastructure-datacom.com 30 35 GigaLine® FO connectivity ■■ Possible types of coupling: SC Duplex, ST Simplex, E 2000, LC Duplex the admissible bending radii of the fibers, thus ensuring that 206 GigaLine® FTTD wall outlets for surface/flush mounting GigaLine® wall outlet for surface mounting GigaLine® wall outlet for flush mounting Features Features Wall outlet for surface mounting. Wall outlet for mounting in ducts and for underfloor mounting. ■■ Downward outlet direction ■■ Downward outlet direction (at an angle of 10°) ■■ Splice tray for four splices ■■ Termination of up to 4 fibers ■■ For 2 SC Duplex or LC Quad couplings ■■ Bending radius > 30 mm in combination with cable ■■ Cover with screw as access protection ■■ Cable entry for 3–10 mm cables ■■ Adherence to the bending radii of approx. 30 mm reservoir KR or cable guide KF ■■ thanks to guided fiber paths Colour: Oyster white RAL 1013 Optical characteristics Insertion loss typ. Optical characteristics G50/125 OM3 0.2 dB E9..10/125 OS2 0.2 dB G50/125 > 40 dB Insertion loss G50/125 typ. E9..10/125 OS2 0.2 dB E9..10/125 OS2 > 50 dB (PC) Return loss G50/125 > 40 dB > 70 dB (APC) typ. E9..10/125 OS2 > 50 dB (PC) Dimensions > 70 dB (APC) 114 mm x 85 mm x 41 mm (H x W x D) OM3 0.2 dB OM3 Return loss typ. OM3 Dimensions 120 mm x 80 mm x 25 mm (H x W x D) Scope of delivery Equipped with 2 fiber optic couplings Accessories With labelling insert (enclosed) Cable ties, coupling protection, wall mounting set Designation GigaLine® wall outlet for surface mounting (1 piece) Configuration Order no. OS2 E9..10/125 OM3 G50/125 SC Duplex Plastic/Cer LKD 9D71 0020 0000 SC Duplex Plastic/PhBz LC Quad Plastic/Cer LKD 9D71 0021 0000 LKD 9D71 0022 0000 LC Quad Plastic/PhBz Designation GigaLine® wall outlet for flush mounting (1 piece) Configuration Order no. 2 LC Duplex Plastic/PhBz LKD 9FK0 3026 0000 2 SC Duplex Plastic/PhBz LKD 9FK0 3003 0000 2 SC Duplex Met/Cer LKD 9FK0 3006 0000 4 ST Simplex Met/PhBz LKD 9FK0 3001 0000 LKD 9D71 0023 0000 Without pigtails GigaLine® wall outlet for surface mounting (1 piece) SC Duplex Plastic/Cer LKD 9D72 0020 0000 SC Duplex Plastic/PhBz LKD 9D72 0021 0000 LC Quad Plastic/Cer LKD 9D72 0022 0000 LC Quad Plastic/PhBz LKD 9D72 0023 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 207 GigaLine® FTTD wall outlets Cable reservoir/splice tray GigaLine® splice tray for cable reservoir KR Features Features For flush-mounted outlet to hold excess cable lengths in For storing fiber optic splices when splicing plug pigtails. the duct and/or safety reserves (up to 4 x 1 m for an overall The separate storage of splice reserve and working reserve diameter of 3 mm). protects the sensitive splice area. ■■ Min. bending radius > 30 mm ■■ Direction-independent cable entry with cable tie strain relief ■■ on entry and exit side Can be equipped with one or two splice holders for 4 fusion splices or mechanical splice connectors ■■ Snaps into cable reservoir KR Dimensions 76 mm x 151 mm x 50/55 mm (H x W x D) 50 mm installation depth (KR50), 55 mm installation depth (KR55) Designation Order no. Designation Order no. GigaLine® cable reservoir KR50 (1 piece) LKD 9FK0 3007 0000 GigaLine® splice tray for cable reservoir KR (1 piece) LKD 9FK0 3029 0000 GigaLine® cable reservoir KR55 (1 piece) LKD 9FK0 3008 0000 www.leoni-infrastructure-datacom.com GigaLine® FO connectivity GigaLine® cable reservoir KR 208 GigaLine® FTTD outlet for cable ducts for installation in ducts GigaLine® outlet EK for cable ducts Features General characteristics Extremely compact outlet for horizontal or vertical installation ■■ in ducts. Can be equipped with 1 duplex coupling or 2 simplex couplings Termination of 1 duct/2 fibers. ■■ Possible types of coupling: SC Duplex, E 2000, LC Quad ■■ Outlet direction: Downwards at an angle of 45°, defined ■■ bending radius in conjunction with suitable mounting bracket MH to the minimum bending radius ■■ ■■ Strain relief using cable ties ■■ Central plate 50 mm x 50 mm The integrated cable guide guarantees adherence The universal central plate can be combined with various switch ranges ■■ Both cables with pre-assembled plugs and plugs assembled on site can be used Designation Configuration Order no. GigaLine® outlet EK for cable ducts (1 piece) 1 LC Quad Plastic/PhBz LKD 9FK0 3031 0000 1 SC Duplex Plastic/PhBz LKD 9FK0 3012 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 209 GigaLine® FTTD mounting bracket for installation in ducts for outlet EK for cable ducts Mounting bracket MH for vertical installation Mounting bracket MH for horizontal installation Features Mounting options For space-saving installation of the outlet EK for cable ducts. T-slot mounting Horizontal or vertical, The mounting bracket is easy to install and guarantees fits ducts from Thealit, OBO/ adherence to the required bending radii. Bettermann, ASYCO and Alusor ■■ Bracket for horizontal or vertical installation with 50 mm Design and 55 mm installation depths available Height 50 mm (MH50) Height 55 mm (MH55) Designation Order no. GigaLine® horizontal mounting bracket MH50 (1 piece) LKD 9FK0 3014 0000 GigaLine® horizontal mounting bracket MH55 (1 piece) LKD 9ZK0 3015 0000 GigaLine® vertical mounting bracket MH50 (1 piece) LKD 9FK0 3016 0000 GigaLine® vertical mounting bracket MH55 (1 piece) LKD 9ZK0 3017 0000 www.leoni-infrastructure-datacom.com GigaLine® FO connectivity GigaLine® mounting bracket MH 210 GigaLine FO patch cords / trunk cables ® www.leoni-infrastructure-datacom.com Office Industry DataCenter 211 GigaLine® FO patch cords / trunk cables 211 o dc o dc o dc dc o dc o dc i i o dc i o dc i Fiber optic patch cord, breakout 212 Fiber optic patch cord, MiniZip 214 Fiber optic patch cord, LC/PC Uniboot 215 Fiber optic patch cord, MTP 216 • MTP I-F(ZN)H 1x12 • MTP I-F(ZN)HH 2x12 GigaLine® Trunk – pre-assembled trunk cables 219 Fiber optic trunk cable, mini breakout 220 Fiber optic trunk cable, breakout 222 Fiber optic trunk cable, outdoor 224 Fiber optic trunk cable, universal 226 Office DataCenter Industry www.leoni-infrastructure-datacom.com GigaLine® FO patch cords / trunk cables GigaLine® FO patch cords 212 GigaLine® Fiber optic patch cord, breakout Type KL-I-V(ZN)HH Breakout patch cord OS2 equipped with LC Duplex, SC Duplex, SC Simplex, E-2000 Simplex GigaLine® Patch Figure 0 Construction Buffered fiber Mechanical characteristics Two semi-tight buffered fibers with strain Bending radius static 35 mm relief as breakout elements (diam. 2.1 mm) (over flat side) dynamic 65 mm Single element 30 mm running parallel under one outer sheath Colour: Orange (multimode), yellow (singlemode) Optical characteristics (typical) Strain relief Aramid Insertion loss For all fiber types 0.2 dB Cable sheath Halogen-free, flame-retardant compound Return loss G62.5/125 OM1e > 40 dB Colour of sheath OM1e, OM2, OM2e ● Orange G50/125 OM2e > 40 dB OM3 > 40 dB OS2 ● Yellow G50/125 OM3 ● Aqua G50/125 OM4 > 40 dB ● Heather violet E9..10/125 OS2 > 50 dB OM4 Dimensions E9..10/125 OS2 APC Overall cable diameter 3.1 x 5.2 mm Thermal characteristics Transport/storage –25 °C up to +70 °C Installation –5 °C up to +50 °C Operating temp. –10 °C up to +70 °C > 70 dB Fire performance Flame retardancy IEC 60332-1/IEC 60332-3-24 Halogen-free IEC 60754-1 Smoke density IEC 61034 Outer sheath Strain relief Tight buffered fiber Subcable sheath www.leoni-infrastructure-datacom.com Office Industry DataCenter DataCenter 213 Length m OM1e G62.5/125 µm OM2e G50/125 µm OM3 G50/125 µm OM4 G50/125 OS2 E9..10/125 Configuration ST-ST (IEC 61754-2) 1.0 LKD 9A12 0290 0000 LKD 9A11 0238 0000 – – LKD 9A13 0237 0000 1.5 LKD 9A12 0291 0000 LKD 9A11 0239 0000 – – LKD 9A13 0238 0000 2.0 LKD 9A12 0403 0000 LKD 9A11 0240 0000 – – LKD 9A13 0239 0000 2.5 LKD 9A12 0292 0000 LKD 9A11 0241 0000 – – LKD 9A13 0240 0000 3.0 LKD 9A12 0404 0000 LKD 9A11 0242 0000 – – LKD 9A13 0241 0000 5.0 LKD 9A12 0293 0000 LKD 9A11 0243 0000 – – LKD 9A13 0242 0000 7.5 LKD 9A12 0294 0000 LKD 9A11 0244 0000 – – LKD 9A13 0243 0000 10.0 LKD 9A12 0295 0000 LKD 9A11 0245 0000 – – LKD 9A13 0244 0000 1.0 LKD 9A12 0265 0000 LKD 9A11 0201 0000 LKD 9A11 1042 0000 LKD 9A11 1111 0000 LKD 9A13 0768 0000 1.5 LKD 9A12 0266 0000 LKD 9A11 0202 0000 LKD 9A11 1043 0000 LKD 9A11 1112 0000 LKD 9A13 0769 0000 2.0 LKD 9A12 0256 0000 LKD 9A11 0203 0000 LKD 9A11 1044 0000 LKD 9A11 1113 0000 LKD 9A13 0770 0000 2.5 LKD 9A12 0267 0000 LKD 9A11 0204 0000 LKD 9A11 1045 0000 LKD 9A11 1114 0000 LKD 9A13 0771 0000 3.0 LKD 9A12 0401 0000 LKD 9A11 0205 0000 LKD 9A11 1046 0000 LKD 9A11 1115 0000 LKD 9A13 0772 0000 5.0 LKD 9A12 0402 0000 LKD 9A11 0206 0000 LKD 9A11 1047 0000 LKD 9A11 1116 0000 LKD 9A13 0773 0000 7.5 LKD 9A12 0268 0000 LKD 9A11 0207 0000 LKD 9A11 1048 0000 LKD 9A11 1117 0000 LKD 9A13 0774 0000 10.0 LKD 9A12 0269 0000 LKD 9A11 0208 0000 LKD 9A11 1049 0000 LKD 9A11 1118 0000 LKD 9A13 0775 0000 Configuration LC Duplex/LC Duplex (IEC 61754-20) 1.0 LKD 9A12 0278 0000 LKD 9A11 0220 0000 LKD 9A11 1051 0000 LKD 9A11 1103 0000 LKD 9A13 0759 0000 1.5 LKD 9A12 0279 0000 LKD 9A11 0221 0000 LKD 9A11 1052 0000 LKD 9A11 1104 0000 LKD 9A13 0760 0000 2.0 LKD 9A12 0362 0000 LKD 9A11 0222 0000 LKD 9A11 1053 0000 LKD 9A11 1105 0000 LKD 9A13 0761 0000 2.5 LKD 9A12 0280 0000 LKD 9A11 0223 0000 LKD 9A11 1054 0000 LKD 9A11 1106 0000 LKD 9A13 0762 0000 3.0 LKD 9A12 0281 0000 LKD 9A11 0224 0000 LKD 9A11 1055 0000 LKD 9A11 1107 0000 LKD 9A13 0763 0000 5.0 LKD 9A12 0282 0000 LKD 9A11 0225 0000 LKD 9A11 1056 0000 LKD 9A11 1108 0000 LKD 9A13 0764 0000 7.5 LKD 9A12 0283 0000 LKD 9A11 0226 0000 LKD 9A11 1057 0000 LKD 9A11 1109 0000 LKD 9A13 0765 0000 10.0 LKD 9A12 0284 0000 LKD 9A11 0227 0000 LKD 9A11 1058 0000 LKD 9A11 1110 0000 LKD 9A13 0766 0000 www.leoni-infrastructure-datacom.com GigaLine® FO patch cords / trunk cables Configuration SC Duplex/SC Duplex (IEC 61754-4) 214 GigaLine® Fiber optic patch cord, MiniZip Type KL-I-V(ZN)H MiniZip patch cord OS2 equipped with LC Duplex, SC Duplex, SC Simplex, E-2000 Simplex GigaLine® Patch MiniZip OS2 GigaLine® Patch MiniZip OM3 GigaLine® Patch MiniZip OM4 MiniZip patch cord OM3/OM2e/OM4 equipped with LC Duplex, SC Duplex, SC Simplex, E-2000 Simplex, MU Construction Cable type KL-I-V(ZN)H 2G50/125 Optical characteristics Insertion loss For all fiber types Buffered fiber Two semi-tight buffered fibers with strain Return loss > 50 dB (PC) relief in figure 8 sheath with separator > 70 dB (APC) (1.8 mm x 3.7 mm) Patch cord OM3/OM4 > 40 dB Strain relief Aramid Cable sheath Halogen-free, flame-retardant compound Colour of sheath OM1e, OM2, OM2e ● Orange Cable diameter 0.2 dB (typical) Patch cord OS2 Laser bandwidth ● Yellow OM3 ● Aqua OM4 ● Heather violet 1.8 mm Thermal characteristics Transport/storage –25 °C up to +70 °C –5 °C up to +50 °C Operating temp. –10 °C up to +70 °C Mechanical characteristics Bending radius static 30 mm (over flat side) 60 mm dynamic 2,000 MHz x km Patch cord OM4 4,700 MHz x km Fire performance Flame retardancy IEC 60332-1/IEC 60332-3-24 OS2 Installation Patch cord OM3 Halogen-free IEC 60754-1 Smoke density IEC 61034 Configuration Patch cord OS2 LC Duplex, SC Duplex, SC Simplex, E-2000 Simplex Patch cord LC Duplex, SC Duplex, SC Simplex, OM3/OM4 E-2000 Simplex, MU Cable length See table, other plug types and lengths on request GigaLine® Patch MiniZip OS2 E9..10/125 Length 2m 2 x LC/PC Duplex 2 x LC/APC Duplex 2 x SC/PC Duplex 2 x SC/APC Duplex 2 x E2000/PC Duplex 2 x E2000/APC Duplex LKD 9A13 0033 0000 LKD 9A13 0090 0000 LKD 9A13 0091 0000 LKD 9A13 0092 0000 LKD 9A13 0093 0000 LKD 9A13 0094 0000 GigaLine® Patch MiniZip OM3 G50/125 Length 2m 2 x LC Duplex 2 x SC Duplex 2 x E2000 Duplex 2 x MU LKD 9A11 0699 0000 LKD 9A11 0700 0000 LKD 9A11 0701 0000 LKD 9A11 0702 0000 GigaLine® Patch MiniZip OM4 G50/125 Length 2m 2 x LC Duplex 2 x SC Duplex 2 x E2000 Duplex 2 x MU LKD 9A11 0693 0000 LKD 9A11 0694 0000 LKD 9A11 0695 0000 LKD 9A11 0696 0000 www.leoni-infrastructure-datacom.com Office DataCenter DataCenter Industry 215 GigaLine® Fiber optic patch cord, LC/PC-Uniboot Type KL-I-V(ZN)H Uniboot patch cord OS2 equipped with 2 x LC DuplexUniboot Uniboot patch cord OM4 equipped with 2 x LC DuplexUniboot GigaLine® Patch LCD-Uniboot OS2 GigaLine® Patch LCD-Uniboot OM3 GigaLine® Patch LCD-Uniboot OM4 Construction Cable type KL-I-V(ZN)H Optical characteristics Insertion loss < 0,4 dB Buffered fiber Two semi-tight buffered fibers under a Return loss 0.2 dB (typical) Patch cord OS2 > 50 dB (PC) > 70 dB (APC) common sheath (round diam. 2.8 mm) Strain relief Aramid Patch cord OM3/OM4 > 40 dB Cable sheath Halogen-free, flame-retardant compound Colour of sheath OM1e, OM2, OM2e ● Orange Cable diameter OS2 ● Yellow OM3 ● Aqua OM4 ● Heather violet 2.8 mm Thermal characteristics Transport/storage –25 °C up to +70 °C Installation –5 °C up to +50 °C Operating temp. –10 °C up to +70 °C Laser bandwidth Patch cord OM3 1,500 MHz x km Patch cord OM4 4,700 MHz x km Fire performance Flame retardancy IEC 60332-1/IEC 60332-3-24 Halogen-free IEC 60754-1 Smoke density IEC 61034 Configuration LC Duplex Uniboot Cable length See table, other plug types and lengths on request Mechanical characteristics Bending radius static 30 mm (over flat side) dynamic 60 mm Tensile strength 300 N       GigaLine® Patch LCD-Uniboot OS2 E9..10/125 GigaLine® Patch LCD-Uniboot OM3 G50/125 GigaLine® Patch LCD-Uniboot OM4 G50/125 Configuration 2 x LC Duplex Uniboot Configuration 2 x LC Duplex Uniboot Configuration 2 x LC Duplex Uniboot LKD 9A13 0713 0000 LKD 9A11 0866 0000 LKD 9A11 0875 0000 2.0 LKD 9A13 0715 0000 LKD 9A11 0868 0000 LKD 9A11 0877 0000 3.0 LKD 9A13 0717 0000 LKD 9A11 0870 0000 LKD 9A11 0879 0000 5.0 LKD 9A13 0718 0000 LKD 9A11 0871 0000 LKD 9A11 0880 0000 7.5 LKD 9A13 0719 0000 LKD 9A11 0872 0000 LKD 9A11 0881 0000 10.0 LKD 9A13 0720 0000 LKD 9A11 0873 0000 LKD 9A11 0882 0000 Length m 1.0 www.leoni-infrastructure-datacom.com GigaLine® FO patch cords / trunk cables Uniboot patch cord OM3 equipped with 2 x LC DuplexUniboot 216 GigaLine® Fiber optic patch cord, MTP Type KL-I-F(ZN)H/KL-I-F(ZN)HH MTP/MPO patch cord GigaLine® Patch MTP I-F(ZN)H 1x12 GigaLine® Patch MTP I-F(ZN)HH 2x12 Description Thermal characteristics Connection-ready MTP patch cord – assembled Transport/storage –25 °C up to +70 °C at both ends with one or two MTP plugs (female) or one MTP Installation –5 °C up to +50 °C (female) to six LC Duplex Uniboot plugs. Operating temp. –10 °C up to +70 °C Construction Mechanical characteristics Cable type Bending radius KL-I-F(ZN)H 1x1 or KL-I-F(ZN)HH 2x12 Strain relief Aramid Cable sheath Halogen-free, flame-retardant compound Colour of sheath OM3 ● Aqua | OM4 ● Heather violet Cable diameter 3.0 mm (for 1x12) 8.9 mm (for 2x12) ■■ static 35 mm | dynamic 65 mm Tensile strength KL-I-F(ZN)H 1x12 300 N KL-I-F(ZN)HH 2x12 600 N 0.3 dB (MTP) For all fiber types 0.2 dB (LCDU) For all fiber types In DataCenters as a patch cord for applications acc. to Return loss GigaLine® Patch MTP–6LCDU (fanout) for multimode applications via two fibers (up to 10GBASE-SR) ■■ KL-I-F(ZN)HH 2x12 Insertion loss ISO/IEC 11801 and EN 50173 (2nd edition) ■■ static 35 mm | dynamic 65 mm Optical characteristics (typical) Field of application ■■ KL-I-F(ZN)H 1x12 OM3/OM4 > 20 dB (MTP) OM3/OM4 > 40 dB (LCDU) GigaLine® Patch 1MTP–1MTP for multimode applications Fire performance Flame retardancy IEC 60332-1/IEC 60332-3-24 via 2 x 4 fibers (40GBASE-SR4) Halogen-free IEC 60754-1 GigaLine Patch 2MTP–2MTP for multimode applications Smoke density IEC 61034 via 2 x 10 fibers (100GBASE-SR10) Equipment on side A Equipment on side B Order no. GigaLine® Patch 12 Designation OM3 6 LC/DU–1 MTP* 6x LC/Dx-Uniboot OM3 MTP female 12 OM3 LKD 9R72 1002 0000 GigaLine® Patch 12 OM4 6 LC/DU–1 MTP* 6x LC/Dx-Uniboot OM4 MTP female 12 OM4 LKD 9R72 4002 0000 GigaLine® Patch 12 OM3 MTP–MTP* MTP female 12 OM3 MTP female 12 OM3 LKD 9R71 5xxx 0000 GigaLine® Patch 12 OM4 MTP–MTP* MTP female 12 OM4 MTP female 12 OM4 LKD 9R71 3xxx 0000 GigaLine® Patch 2x12 OM3 MTP–MTP* 2x MTP female 2x12 OM3 2x MTP female 2x 12 OM3 LKD 9R71 6xxx 0000 GigaLine® Patch 2x12 OM4 MTP–MTP* 2x MTP female 2x12 OM4 2x MTP female 2x 12 OM4 LKD 9R71 4xxx 0000 * Logically crossed xxx = Length in m. 1 piece per packing unit. www.leoni-infrastructure-datacom.com Office Office Industry DataCenter DataCenter GigaLine® FO patch cords / trunk cables 217 www.leoni-infrastructure-datacom.com 218 www.leoni-infrastructure-datacom.com Office Industry DataCenter 219 GigaLine® Trunk – pre-assembled trunk cables Safely through "thick and thin" Ready-to-connect units are at the heart of our fiber optic Time is money system technology. Our pre-assembled cables (GigaLine® GigaLine® trunk cables stand for reliable and calculable trunk cables) guarantee rapid, reliable and economical installation. Installations times are short. All GigaLine® 19" installation. Coordinated system components ensure trunk cable housings have recesses on the back in which the the quality of the transmission line. Installations times divider head is mounted to prevent rotation. The fast assembly are calculable. minimises any downtime e.g. as a result of an IT system's A lasting solution or fitting the plugs on site, which would sometimes involve On-site installation frequently takes place under unfavourable adverse conditions. This also does away with costly outlay on conditions. Moisture, dirt and poorly accessible areas are splicing equipment and specially trained staff. GigaLine® trunk nothing unusual. This is why we use an IP67 protection cables can also be used as a cable pre-assembled at one end. class wire ripple tube for our GigaLine® trunk cables with universal or outdoor cable. Thanks to their particularly strong Fields of application construction with an encapsulated cable divider and bolted-on GigaLine® trunk cables are ideal for backbone cabling in wire ripple tube, our trunk cables are protected against water the primary and secondary segments as well as for collapsed spray and non-crush. They are ideal for harsh construction backbone cabling. site environments and outdoor cabling systems. Indoor cables are fitted with dust protection without strain relief to prevent Quality means maximum safety soiling of the plugs. The plugs are assembled with high quality ceramic ferules under clean conditions. The plug faces are polished to the GigaLine® trunk cables ensure that ambient conditions do not highest standard, thereby ensuring outstanding plug transitions affect the quality of the transmission lines – either during or in reproducible quality (input and return attenuation). A test after installation. The feeder aid is flexible and has a small cross certificate with the attenuation readings of each fiber is section. This enables pre-assembled trunk cables to be easily fed supplied with the product. There is also the option of having into tight, twisty manholes and installation channels. A frictional OTDR measurements. connection is formed with the divider head. It acts on the strain relief elements and the sheaths. The fibers thereby remain free of tension. The divider head design guarantees the stability of the physical parameters and a long service life. www.leoni-infrastructure-datacom.com GigaLine® FO patch cords / trunk cables temporary shutdown. There is no need for splicing the cables 220 GigaLine® Fiber optic trunk cable, mini breakout Type KL-I-V(ZN)H Pre-assembled at both ends GigaLine® Trunk Mini-Breakout Optical characteristics Construction Single elements Up to 12 semi-tight buffered fibers Insertion loss typ. For all fiber types 0.2 dB Return loss typ. with diameter 0.9 mm G62.5/125 OM1e > 40 dB Blue (1), orange (2), green (3), brown (4), G50/125 OM2e > 40 dB grey (5), white (6), red (7), black (8), yellow (9), G50/125 OM3 > 40 dB violet (10), pink (11), turquoise (12) G50/125 OM4 > 40 dB Aramid threads E9..10/125 OS2 > 50 dB Halogen-free, flame-retardant compound E9..10/125 OS2 APC > 70 dB Colour code acc. to EIA/TIA 598C Strain relief Cable sheath Patch element OM1e, OM2e ● Orange OS2 ● Yellow Mechanical characteristics OM3 ● Aqua Bending radius OM4 ● Heather violet static 10 x overall diameter dynamic 15 x overall diameter diam. 0.9 mm, shortest patch element 55 cm, gradation 5 cm Fire performance Dust protection Protected with plastic tube Flame retardancy IEC 60332-1/IEC 60332-3-24 Protection class Acc. to IP44 Halogen-free IEC 60754-1 Smoke density IEC 61034 Thermal characteristics Transport/storage –25 °C up to +70 °C Installation –5 °C up to +50 °C Operating temp. –10 °C up to +50 °C www.leoni-infrastructure-datacom.com Office Industry DataCenter DataCenter 221 Plug SC E2000 LC Singlemode OS2 E9..10/125 4 LKD 9Vxx x08B 0000 LKD 9Vxx x08L 0000 6 LKD 9Vxx x08C 0000 LKD 9Vxx x08M 0000 LKD 9Vxx x08E 0000 LKD 9Vxx x08O 0000 8 12 LKD 9Vxx x08N 0000 4 LKD 9Vxx x095 0000 LKD 9Vxx x09F 0000 6 LKD 9Vxx x096 0000 LKD 9Vxx x09G 0000 8 LKD 9Vxx x097 0000 12 LKD 9Vxx x098 0000 Multimode OM3 G50/125 4 6 8 12 Multimode OM1e G62.5/125 4 LKD 9Vxx x10O 0000 LKD 9Vxx x10Y 0000 6 LKD 9Vxx x10P 0000 LKD 9Vxx x10Z 0000 LKD 9Vxx x10R 0000 LKD 9Vxx x111 0000 8 12 xxx = Length in metres, measured from plug side A to plug side B Other plug types and fiber numbers on request www.leoni-infrastructure-datacom.com GigaLine® FO patch cords / trunk cables Multimode OM2e G50/125 222 GigaLine® Fiber optic trunk cable, breakout Type KL-I-V(ZN)HH Pre-assembled at both ends GigaLine® Trunk Breakout Construction Single elements Optical characteristics Up to 12 buffered fibers with strain relief Insertion loss typ For all fiber types 0.2 dB Return loss typ. G62.5/125 OM1e > 40 dB G50/125 OM2e > 40 dB under one sheath, diameter 2.1 mm Strain relief Aramid threads Cable sheath Halogen-free, flame-retardant compound OM1e, OM2e ● Orange G50/125 OM3 > 40 dB OS2 ● Yellow G50/125 OM4 > 40 dB OM3 ● Aqua E9..10/125 OS2 > 50 dB OM4 ● Heather violet E9..10/125 OS2 APC > 70 dB Patch element Shortest patch element 55 cm, Dust protection Gradation 5 cm Mechanical characteristics Protection class Protected with plastic tube Bending radius acc. to IP44 static 10 x overall diameter dynamic 15 x overall diameter Thermal characteristics Fire performance Transport/storage –25 °C up to +70 °C Flame retardancy IEC 60332-1/IEC 60332-3-24 Installation –5 °C up to +50 °C Halogen-free IEC 60754-1 Operating temp. –10 °C up to +50 °C Smoke density IEC 61034 www.leoni-infrastructure-datacom.com Office Industry Industry DataCenter DataCenter 223 Plug SC E2000 LC Singlemode OS2 E9..10/125 4 LKD 9Vxx x11D 0000 LKD 9Vxx x11N 0000 8 LKD 9Vxx x11F 0000 LKD 9Vxx x11P 0000 12 LKD 9Vxx x11G 0000 LKD 9Vxx x11Q 0000 6 Multimode OM2e G50/125 4 LKD 9Vxx x127 0000 6 8 LKD 9Vxx x12A 0000 LKD 9Vxx x12K 0000 Multimode OM3 G50/125 4 6 8 12 Multimode OM1e G62.5/125 4 LKD 9Vxx x14U 0000 LKD 9Vxx x156 0000 LKD 9Vxx x15I 0000 8 LKD 9Vxx x14W 0000 LKD 9Vxx x158 0000 LKD 9Vxx x15K 0000 12 LKD 9Vxx x14Y 0000 LKD 9Vxx x15A 0000 LKD 9Vxx x15M 0000 6 xxx = Length in metres, measured from plug side A to plug side B Other plug types and fiber numbers on request www.leoni-infrastructure-datacom.com GigaLine® FO patch cords / trunk cables 12 224 GigaLine® Fiber optic trunk cable, outdoor Type KL-A-DQ(ZN)B2Y Pre-assembled at both ends GigaLine® Trunk A-DQ(ZN)B2Y IP67 Construction Single elements Size of the divider head Up to 48 buffered fibers with strain relief diameter divider for 2–12 fibers 25 mm under one sheath, diameter 1.8 mm head max. for 16–48 fibers 33 mm Colour code Acc. to IEC 60304 Strain relief Non-metallic (glass rovings) diameter pull tool for 2–12 fibers 33 mm Cable sheath PE, resistant to UV rays, max. for 16–48 fibers 43 mm Colour: Black Divider head Aluminium Mechanical characteristics Strain relief 600 N Bending radius Patch element Shortest patch element 55 cm, static 15 x overall diameter dynamic 20 x overall diameter gradation 5 cm Strain relief 100 N Dust protection Protective tube Protection class Acc. to IP67 Fire performance Thermal characteristics Transport/storage –25 °C up to +70 °C Installation –5 °C up to +50 °C Operating temp. –25 °C up to +70 °C Flame retardancy IEC 60332-1/IEC 60332-3-24 Halogen-free IEC 60754-1 Smoke density IEC 61034 Other characteristics Longitudinally IEC 60794-1-2 F5 watertight Optical characteristics Insertion loss typ For all fiber types 0.2 dB Return loss typ. G62.5/125 OM1e > 40 dB G50/125 OM2e > 40 dB G50/125 OM3 > 40 dB G50/125 OM4 > 40 dB E9..10/125 OS2 > 50 dB E9..10/125 OS2 APC > 70 dB www.leoni-infrastructure-datacom.com Office Office Industry Industry DataCenter 225 Plug SC E2000 E2000HRL LC Singlemode OS2 E9..10/125 4 LKD 9Vxx x005 0000 LKD 9Vxx x00J 0000 LKD 9Vxx x00Q 0000 6 LKD 9Vxx x006 0000 LKD 9Vxx x00K 0000 LKD 9Vxx x00R 0000 8 LKD 9Vxx x007 0000 LKD 9Vxx x00L 0000 LKD 9Vxx x00S 0000 12 LKD 9Vxx x008 0000 LKD 9Vxx x00M 0000 LKD 9Vxx x00T 0000 16 LKD 9Vxx x009 0000 LKD 9Vxx x00N 0000 LKD 9Vxx x00U 0000 24 LKD 9Vxx x00A 0000 LKD 9Vxx x00O 0000 LKD 9Vxx x00V 0000 LKD 9V10 0647 0000 48 LKD 9Vxx x00B 0000 LKD 9Vxx x00P 0000 LKD 9Vxx x00W 0000 LKD 9Vxx x01A 0000 Multimode OM2e G50/125 LKD 9Vxx x01B 0000 LKD 9Vxx x01P 0000 6 LKD 9Vxx x01C 0000 LKD 9Vxx x01Q 0000 8 LKD 9Vxx x01D 0000 LKD 9Vxx x025 0000 12 LKD 9Vxx x01E 0000 LKD 9Vxx x026 0000 16 LKD 9Vxx x023 0000 LKD 9Vxx x027 0000 24 LKD 9Vxx x01G 0000 LKD 9Vxx x028 0000 48 LKD 9Vxx x01H 0000 LKD 9Vxx x029 0000 Multimode OM3 G50/125 4 6 8 12 LKD 9V10 062A 0000 LKD 9Vxx x62J 0000 16 24 LKD 9Vxx x65G 0000 Multimode OM1e G62.5/125 4 LKD 9Vxx x03G 0000 LKD 9Vxx x03U 0000 6 LKD 9Vxx x03H 0000 LKD 9Vxx x03V 0000 8 LKD 9Vxx x03I 0000 LKD 9Vxx x03W 0000 12 LKD 9Vxx x03J 0000 LKD 9Vxx x03X 0000 LKD 9Vxx x03L 0000 LKD 9Vxx x03Z 0000 16 24 xxx = Length in metres, measured from plug side A to plug side B Other plug types and fiber numbers on request www.leoni-infrastructure-datacom.com GigaLine® FO patch cords / trunk cables 4 226 GigaLine® Fiber optic trunk cable, universal Type KL-U-DQ(ZN)BH Pre-assembled at both ends GigaLine® Trunk U-DQ(ZN)H  IP67 Construction Single elements Size of the divider head Up to 48 buffered fibers with strain relief diameter divider for 2–12 fibers 25 mm under one sheath, diameter 1.8 mm head max. for 16–48 fibers 33 mm Colour code Acc. to IEC 60304 Strain relief Non-metallic (glass rovings) diameter pull tool for 2–12 fibers 33 mm Cable sheath Halogen-free, flame-retardant compound max. for 16–48 fibers 43 mm Colour: Black Divider head Aluminium Strain relief 600 N Mechanical characteristics Patch element diam. 1.8 mm, assorted colours acc. to Bending radius IEC 60304, shortest patch element 55 cm, static 15 x overall diameter dynamic 20 x overall diameter gradation 5 cm Strain relief 100 N Fire performance Dust protection Protective tube IP67 Protection class Acc. to IP67 Flame retardancy IEC 60332-1/IEC 60332-3-24 Halogen-free IEC 60754-1 Smoke density IEC 61034 Thermal characteristics Transport/storage –25 °C up to +70 °C Other characteristics Installation –5 °C up to +50 °C Operating temp. –25 °C up to +70 °C Longitudinally IEC 60794-1-2 F5 watertight Optical characteristics Insertion loss typ For all fiber types 0.2 dB Return loss typ. G62.5/125 OM1e > 40 dB G50/125 OM2e > 40 dB G50/125 OM3 > 40 dB G50/125 OM4 > 40 dB E9..10/125 OS2 > 50 dB E9..10/125 OS2 APC > 70 dB www.leoni-infrastructure-datacom.com Office Industry Industry DataCenter DataCenter 227 Plug SC E2000 E2000HRL LC Singlemode OS2 E9..10/125 4 LKD 9Vxx x61N 0000 LKD 9Vxx x61T 0000 LKD 9Vxx x61Z 0000 LKD 9Vxx x60H 0000 6 LKD 9Vxx x61O 0000 LKD 9Vxx x61U 0000 LKD 9Vxx x620 0000 LKD 9Vxx x60I 0000 8 LKD 9Vxx x61P 0000 LKD 9Vxx x61V 0000 LKD 9Vxx x621 0000 LKD 9Vxx x60K 0000 12 LKD 9Vxx x61Q 0000 LKD 9Vxx x61W 0000 LKD 9Vxx x622 0000 LKD 9Vxx x60L 0000 24 LKD 9Vxx x61R 0000 LKD 9Vxx x61X 0000 LKD 9Vxx x623 0000 LKD 9Vxx x60M 0000 48 LKD 9Vxx x61S 0000 LKD 9Vxx x61Y 0000 LKD 9Vxx x624 0000 LKD 9Vxx x60N 0000 Multimode OM2e G50/125 LKD 9Vxx x61G 0000 LKD 9Vxx x60B 0000 6 LKD 9Vxx x61H 0000 LKD 9Vxx x60C 0000 8 LKD 9Vxx x61I 0000 LKD 9Vxx x60D 0000 12 LKD 9Vxx x61K 0000 LKD 9Vxx x60E 0000 24 LKD 9Vxx x61L 0000 LKD 9Vxx x60F 0000 48 LKD 9Vxx x61M 0000 LKD 9Vxx x60G 0000 Multimode OM3 G50/125 4 LKD 9Vxx x61A 0000 LKD 9Vxx x615 0000 6 LKD 9Vxx x61B 0000 LKD 9Vxx x616 0000 8 LKD 9Vxx x61C 0000 LKD 9Vxx x617 0000 12 LKD 9Vxx x61D 0000 LKD 9Vxx x618 0000 24 LKD 9Vxx x61E 0000 LKD 9Vxx x619 0000 48 LKD 9Vxx x61F 0000 LKD 9Vxx x60A 0000 Multimode OM4 G50/125 4 LKD 9Vxx x60U 0000 LKD 9Vxx x609 0000 6 LKD 9Vxx x60V 0000 LKD 9Vxx x610 0000 8 LKD 9Vxx x60W 0000 LKD 9Vxx x611 0000 12 LKD 9Vxx x60X 0000 LKD 9Vxx x612 0000 24 LKD 9Vxx x60Y 0000 LKD 9Vxx x614 0000 48 LKD 9Vxx x60Z 0000 LKD 9Vxx x613 0000 Multimode OM1e G62.5/125 4 LKD 9Vxx x60O 0000 6 LKD 9Vxx x60P 0000 8 LKD 9Vxx x60Q 0000 12 LKD 9Vxx x60R 0000 24 LKD 9Vxx x60S 0000 48 LKD 9Vxx x60T 0000 xxx = Length in metres, measured from plug side A to plug side B Other plug types and fiber numbers on request www.leoni-infrastructure-datacom.com GigaLine® FO patch cords / trunk cables 4 228 GigaLine DataCenter Links ® www.leoni-infrastructure-datacom.com Office Industry DataCenter 229 GigaLine® DataCenter links GigaLine® DataCenter links 228 dc DataCenter link dc DataCenter link • DClink OS2 E9.10/125 • DClink OM3 G50/125 • DClink OM4 G50/125 232 dc DataCenter MTP module • DC MTP module OS2 E9..10/125 • DC MTP module OM3 G50/125 • DC MTP module OM4 G50/125 233 o dc i Office DataCenter Industry www.leoni-infrastructure-datacom.com 231 GigaLine® DataCentre links 230 • DClink 40/100 OM3 G50/125 • DClink 40/100 OM4 G50/125 230 GigaLine® DataCenter links Quick & easy solution for ready-to-use links in DataCenters DataCenters have special requirements since downtimes For transmissions up to 10 Gbit/s, fiber pairs are separated from there can have catastrophic consequences. the 12x fiber bundle using an MPO to LC duplex fanout (see It must therefore be ensured that disruptions are kept to Figure) so that 144 channels are available per rack unit. a minimum, particularly when carrying out renovation work during operation. LEONI has developed systems for this that take these requirements into consideration right from the construction stages of a new DataCenter. As well as ensuring adherence to the applicable cabling standards, our systems also offer countless options for quick and reliable construction and renovation of DataCenters. DClink 40/100 is a cabling system that is suitable for all transmission protocols. It is delivered as a tested permanent GigaLine® patch cord MPO-6LC-Dx (fanout) FO link and consists of a cable with 8x12 OM3/OM4 fibers that is already equipped with a partial patch panel at both ends. To retrofit the system for 40 Gbit/s systems (parallel transmission The pre-assembled link just has to be installed by snapping over 2 x 4 fibers), the fanout simply has to be replaced by simplex it into the socket provided in the patch panel. This allows three MPO patch cords (see Figure) with 12 fibers (24 systems per GigaLine® DClink partial patch panels with 8 MPO couplings rack unit). each in the patch panel to be fitted at a single level. GigaLine® patch cord MPO-MPO (12 OM3/OM4) Two simplex MPO patch cords, i.e. 2x12 fibers (parallel transmission over 2 x 10 fibers) are used for 100 Gbit/s (12 systems per rack unit). VarioLine® DClink sockets with 3 GigaLine® DClink modules 40/100 Gbit/s with 8 MPO each In contrast to conventional cabling systems in which the link has to be replaced, GigaLine® DClink offers numerous The use of low or medium data rates of up to 10 Gbit/s and advantages: higher data rates of up to 40 and 100 Gbit/s can thus be ■■ replacing the patch cords (no need to modify the permanent realised without modifications to the permanently installed installation) GigaLine® DClink cabling. This allows the fibers to be used both individually for applications up to 10 Gbit/s and in parallel for ■■ Rapid and economical installation as GigaLine® DClink is delivered fully assembled 40 and 100 Gbit/s. Migration or connection to the necessary transmission technology is carried out via application-specific Migratability to all data rates used is possible by simply ■■ High reliability and quality as GigaLine® DClink is tested before leaving the factory patch cords. ■■ Clear arrangement in spite of high packing density www.leoni-infrastructure-datacom.com Office Office Industry DataCenter DataCenter 231 GigaLine® DataCenter link Connection-ready links up to 100 Gbit/s Description DClink module Connection-ready link – one DClink module in a high tensile Housing Steel panel, front Jet black RAL 9005 strength connection with a high-quality universal cable at each Dimensions 40 mm x 135 mm x 150 mm (H x W x D) end. The housing can be opened if necessary and the divider Configuration 8 MTP/MPO containing the patch elements removed and pulled through Insertion loss 0.25 dB (typ.) tight openings (≥ diam. 35 mm) with the help of a pull-in tube. Return loss OM3 > 20 dB OM4 > 20 dB Field of application In DataCenters acc. to ISO/IEC 11801 and EN 50173 (2nd edition). Accessories (optional) DClink OS3 GigaLine® DClink pull tool For all applications from Classes > Order no.: LKD 9R00 0008 0000 OF-100 (40 and 100 GBE), OF-300 (10 GbE), OF-500 (GbE/Fiber Channel) and OF-2000 (Fast Ethernet) DClink OM4 For all applications from Classes > OF-100(40 and 100 GBE), OF-300 (GigaLine 550), (10 GbE), OF-500 (GbE/FiberChannel) and OF-2000 (Fast Ethernet) Colour Designation Cable type GigaLine® DClink 40/100 OM3 KL-I-F(ZN)H(ZN)H 8x12 24 G50/125 2.5B1500 0.7F500 (IEC 60793-2 A1a.2) Aqua KL-I-F(ZN)H(ZN)H 8x12 24 G50/125 2.5B3500 0.7F500 (IEC 60793-2 A1a.3) Heather violet GigaLine® DClink 40/100 OM4 Configuration 8 MTP(male) – 8 MTP(male) Strain relief MHz x km N 2,000 1,000 2,000 Cable sheath Sheath diam. mm Halogen-free and flameretardant Order no. GigaLine® DClink OM3 G50/125 GigaLine® DClink OM4 G50/125 LKD 9R31 6xxx 0000 LKD 9R31 nxxx 0000 xxx = Length between the link modules in m. Other configurations on request. 1 piece per packing unit. www.leoni-infrastructure-datacom.com Laser bandwidth 14.0 GigaLine® DataCentre links GigaLine® DClink 40/100 OM3 G50/125 GigaLine® DClink 40/100 OM4 G50/125 232 GigaLine® DataCenter link Connection-ready links GigaLine® DClink OS2 E9.10/125 GigaLine® DClink OM3 G50/125 GigaLine® DClink OM4 G50/125 Description DClink module Connection-ready link – one DClink module in a high tensile Housing Steel panel, front Jet black RAL 9005 strength connection with a high-quality universal cable at each Dimensions 40 mm x 135 mm x 150 mm (H x W x D) end. The housing can be opened if necessary and the divider Configuration Fiber optic connector (see table) containing the patch elements removed and pulled through Insertion loss 0.2 dB (typ.) tight openings (≥ diam. 35 mm) with the help of a pull-in tube. Return loss OS2 > 50 dB (PC), > 70 dB (APC) OM3 > 40 dB OM4 > 40 dB Field of application In DataCenters acc. to ISO/IEC 11801 and EN 50173 (2nd edition). DClink OS2 For all applications up to Class OF-10000 Accessories (optional) DClink OM3 For all applications from Classes GigaLine® DClink pull tool Order no.: LKD 9R00 0008 0000 OF-300 (10 GbE), OF-500 (GbE/Fiber Channel) and OF-2000 (Fast Ethernet) DClink OM4 For all applications from Classes > OF-300 (GigaLine 550), (10 GbE), OF-500 (GbE/FiberChannel) and OF-2000 (Fast Ethernet) Laser bandwidth Strain relief MHz x km N Designation Cable type GigaLine® DClink OS2 KL-U-DQ(ZN)BH 1x12 or 24 E9/125 0.36F3.5/0.22H18 (ITU G652.D) – GigaLine® DClink OM3 KL-U-DQ(ZN)BH 1x12 or 24 G50/125 2.5B1500 0.7F500 (IEC 60793-2 A1a.2) 2,000 GigaLine® DClink OM4 KL-U-DQ(ZN)BH 1x12 or 24 G50/125 2.5B3500 0.7F500 (IEC 60793-2 A1a.3) 4,700 Configuration Cable sheath Sheath diam. mm 1,000 Halogen-free and flameretardant 7.0 (12 fibers) 7.5 (24 fibers) Order no. GigaLine® DClink OS2 E9..10/125 GigaLine® DClink OM3 G50/125 GigaLine® DClink OM4 G50/125 6 LC Duplex PC – 6 LC Duplex PC* LKD 9R20 8xxx 0000 LKD 9R30 8xxx 0000 LKD 9R10 8xxx 0000 6 LC Duplex PC – 6 SC Duplex PC* LKD 9R20 9xxx 0000 LKD 9R30 9xxx 0000 LKD 9R10 9xxx 0000 6 SC Duplex PC – 6 SC Duplex PC* LKD 9R21 0xxx 0000 LKD 9R31 0xxx 0000 LKD 9R11 0xxx 0000 12 LC Duplex PC – 12 LC Duplex PC* LKD 9R21 1xxx 0000 LKD 9R31 5xxx 0000 LKD 9R11 1xxx 0000 12 E2000 Simplex PC – 12 E2000 Simplex PC* LKD 9R21 2xxx 0000 LKD 9R31 2xxx 0000 LKD 9R11 2xxx 0000 6 LC Duplex PC – 12 E2000 Simplex PC* LKD 9R21 3xxx 0000 LKD 9R31 3xxx 0000 LKD 9R11 3xxx 0000 *Twisted in pairs xxx = Length between the link modules in m. Other configurations on request. 1 piece per packing unit. www.leoni-infrastructure-datacom.com Office Office Industry DataCenter DataCenter 233 GigaLine® DataCenter MTP module for installation in DClink frame Description DC MTP module Connection-ready MTP module for installation in a DClink frame. Housing Steel panel, front Jet black RAL 9005 Dimensions 40 mm x 135 mm x 150 mm (H x W x D) Field of application In DataCenters and in structured cabling acc. to ISO/IEC 11801 Front side and EN 50173 (2nd edition). Configuration For all applications from Classes > OF-300 (GigaLine 550)(10 GbE), Insertion loss typ. 0.2 dB OF-500 (GbE/FiberChannel) and OF-2000 (Fast Ethernet). Return loss > 50 dB (SM, PC), > 70 dB (SM, APC), Up to 12 LC Duplex, 6 SC Duplex, 12 SC Simplex, 12 E-2000 Simplex > 40 dB (MM) Rear Configuration 1x or 2x MTP® (male) Insertion loss typ. 0.3 dB Return loss > 55 dB (SM), > 20 dB (MM) Fiber types OS2/OM4/OM3 Designation Configuration Order no. Configuration Order no. 1 x GigaLine® MTP module OS2 E9..10/125 6 LC Duplex PC* LKD 9R70 0008 0000 6 LC Duplex PC** LKD 9R7G 0008 0000 2 x GigaLine® MTP module OS2 E9..10/125 12 LC Duplex PC* LKD 9R70 0009 0000 12 LC Duplex PC** LKD 9R7G 0009 0000 1 x GigaLine® MTP module OM4 G50/125 6 LC Duplex PC* LKD 9R70 0010 0000 6 LC Duplex PC** LKD 9R7G 0010 0000 2 x GigaLine® MTP module OM4 G50/125 12 LC Duplex PC* LKD 9R70 0011 0000 12 LC Duplex PC** LKD 9R7G 0011 0000 1 x GigaLine® MTP module OM3 G50/125 6 LC Duplex PC* LKD 9R70 0012 0000 6 LC Duplex PC** LKD 9R7G 0012 0000 2 x GigaLine® MTP module OM3 G50/125 12 LC Duplex PC* LKD 9R70 0013 0000 12 LC Duplex PC** LKD 9R7G 0013 0000 1 piece per packing unit. * Logically crossed www.leoni-infrastructure-datacom.com ** Twisted in pairs GigaLine® DataCentre links GigaLine® DC MTP module OS2 E9..10/125 GigaLine® DC MTP module OM3 G50/125 GigaLine® DC MTP module OM4 G50/125 234 GigaLine Acceptance measurement ® www.leoni-infrastructure-datacom.com Office Office Industry DataCenter 235 Acceptance measurement for GigaLine® cabling systems The acceptance measurement for GigaLine® cabling systems The set measuring range must be twice as big as the is carried out in accordance with the requirements of ISO/IEC transmission link to be measured. The pulse width of the OTDR 11801 or EN 50173-1:2007. DIN ISO/IEC 14763-3 is also relevant should be chosen as short as possible. This keeps the dead zones to the acceptance measurement. at reflected events to a minimum. For an OTDR measurement, a launch fiber and receive fiber Index-adjusting materials must not be used. must be used. These must be longer than the dead zone of the OTDR being used. For multimode links, the fiber should be at least 100 m in length; for singlemode links, the fiber should be Maximum attenuation of the transmission links in dB Class 850 nm at least 500 m in length. A bidirectional measurement is necessary to avoid or eliminate measurement errors due to different backscatter coefficients if the overall link consists of several spliced or patched sublinks. Attenuation meters Both attenuation meters and OTDR are vital for professional fiber optic installation. The test engineer must have a valid calibration certificate for the testing device. www.leoni-infrastructure-datacom.com Multimode Singlemode 1,300 nm 1,310 nm 1,550 nm OF 300 2.55 1.95 1.80 1.80 OF 500 3.25 2.25 2.00 2.00 OF 2000 8.50 4.50 3.50 3.50 OF 5000 4.00 4.00 OF 10000 6.00 6.00 OTDR Fiber identifiers 236 VarioLine® Modular system peripherals Consolidation point and underfloor solutions www.leoni-infrastructure-datacom.com Office Industry DataCenter 237 VarioLine® CP – consolidation point range 236 240 241 o Consolidation point housing o Consolidation point housing For 6, 12, 24-port module panels Module panels with 6, 12, 24 ports •C  an be equipped with ELine 1200® EC7 modules • Can be equipped with VarioKeystone® modules • Can be equipped with VarioKeystone® cable plugs 242 Module panels with 6, 12, 24 ports •C  an be equipped with keystone modules • Can be equipped with GigaLine™ SC Duplex couplings • Can be equipped with GigaLine™ LC Duplex couplings 243 Floor outlet Round/rectangular 244 o o o VarioLine® DC – DataCenter range o DClink frame 19"/1 RU o DataCenter accessories o DataCenter cable routing panel 19"/1 RU • F or holding up to 3 DClink modules •D  Clink dummy cover www.leoni-infrastructure-datacom.com 253 VarioLine® UF – underfloor systems/ floorbox solutions System overview 254 o Mounting plates for underfloor systems • For installing wall outlets • For installing adapter panels 258 259 o Adapter panels for underfloor systems 260 o o o o Excess-length module 262 o dc i Splice tray 262 Cable retainer 263 Dummy cover 263 Office DataCenter Industry 247 248 249 • With 82 mm metal clips • With 115 mm metal clips • With 78 mm plastic clips VarioLine® UF – underfloor systems 239 •C  an be equipped with MegaLine® Connect45 modules • Can be equipped with VarioKeystone® modules 250 VarioLine® Modular system peripherals VarioLine® Modular system peripherals 238 www.leoni-infrastructure-datacom.com Office Office Industry DataCenter DataCenter 239 VarioLine®  CP – consolidation point range for copper and fiber optic connectivity The consolidation point range is an efficient and cost- The robust VarioLine® consolidation points are made of galvanised effective solution for designing highly flexible floor, steel panel and are available in three sizes for 6, 12 and 24 ports. DataCenter or industrial cabling systems. There are different module panels available for VarioLine® In office cabling (EN 50173-2), consolidation points (CPs) CP housings: between floor distributors (FD) and telecommunication outlets ■■ VarioKeystone® modules (TO) offer extremely flexible solutions for rapidly changing ■■ VarioKeystone® link extenders office configurations. ■■ MegaLine® Connect45 modules ■■ ELine® 1200 EC7 modules The CP can be installed in raised floors, suspended ceilings, ■■ All common keystone modules columns or ducts. From there, flexible cables (CP cables) lead ■■ GigaLine® LC Duplex to the data outlets at the workstation. ■■ GigaLine® SC Duplex The CP cabling connects the permanent cabling with modular If necessary, the VarioLine® CP range can be expanded by or mobile office systems such as partitions or office furniture into using additional module panels for copper as well as fiber which the TO is already installed. In industrial cabling, a so-called optic systems. intermediate distributor (ID) is used to connect the floor distributor (FD) with the telecommunication outlet (TO) which Features of VarioLine®: for example allows temporary machine cablings (EN 50173-3). ■■ The easy snap-in installation of the cover on the floor or zone distributor side makes troublesome screwing and the use provide an additional patching option between a zone ■■ The patch side is covered by a hinged cover with a strip brush. distributor (ZD) and equipment outlet (EO) (EN50173-5). ■■ The incoming cables and the patch cords can be held by cable ties. ■■ The housings can be earthed if necessary. ■■ The CP cables pass through the raised floor via the necessary floor outlets which are installed in the base plate. ■■ VarioLine® CP floor outlets can be closed flush with the floor when they are not required and are set upright to pass cables through. ■■ www.leoni-infrastructure-datacom.com The cover then also protects the cables as they come out. VarioLine® Modular system peripherals of special tools unnecessary. In DataCenters, CPs as local distribution points (LDP) can 240 VarioLine®  Consolidation point housing 6-port, with DIN rail clip Fig. 2 6-port module panel in VarioKeystone® format Fig. 3 6-port module panel in keystone format Fig. 1 Consolidation point housing VarioLine® CP6-B VarioLine® CPL6-B VarioLine® CPL6-B VarioLine® CP6-B Fig. 4 6-port protective flap/ strip brush consolidation point housing 6-port VarioKeystone® module panel 6-port keystone module panel 6-port protective flap/strip brush Description Configuration of VarioKeystone® module panel For installation in raised floors or suspended ceilings. CP housing ■■ For up to 6 VarioKeystone® single modules or up to 3 VarioKeystone® double modules with strain relief using cable ties (not included in the scope of delivery). Can be equipped with MegaLine® Connect45 or VarioKeystone® modules. Configuration of keystone module panel ■■ For up to 6 MegaLine® Connect45 modules A protective flap with strip brush can optionally be used on the patch side. Mounting ■■ ■■ Modular (interchangeable module panel) ■■ Also available with 12/24 ports as an option ■■ Robust housing made from galvanised steel panel ■■ RoHS-compliant The CP housing is attached using the DIN rail mounting technique (a suitable clip is included) ■■ The housing can alternatively be attached using screws or nailed dowels (not included in the scope of delivery) ■■ The module panel is attached by snapping it into the housing ■■ The modules are attached by snapping them into the module panel Fig. Designation Dimensions Order no. 1 VarioLine® CP6-B consolidation point housing 33 x 121.5 x 100 mm (H x W x D) LKD 9ZE6 1007 0000 2 VarioLine® CPL6-B 6-port VarioKeystone® module panel 31 x 121 mm (H x W) LKD 9ZE6 1014 0000 3 VarioLine® CPL6-B 6-port keystone module panel 31 x 121 mm (H x W) LKD 9ZE6 1064 0000 4 VarioLine® CP6-B 6-port protective flap with strip brush 31 x 121 mm (H x W) LKD 9ZE6 1008 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 241 VarioLine®  Consolidation point housing for 6, 12, 24-port module panels Fig. 1 Consolidation point housing for 6-port module panel Fig. 2 Consolidation point housing for 12-port module panel Fig. 3 Consolidation point housing for 24-port module panel VarioLine® CP6/CP12/CP24 Description Housing For installation in raised floors or suspended ceilings, can be Housing Galvanised sheet panel equipped with 6, 12 or 24-port module panels in different Dimensions CP 6 55 mm x 155 mm x 215 mm (H x W x D) designs. CP 12 55 mm x 290 mm x 215 mm (H x W x D) The module panel is installed by pushing it into place; CP 24 55 mm x 550 mm x 215 mm (H x W x D) can additionally be screwed. Accessories ■■ Bottom plate with hinged flap and dust protective brush see from page 90 6, 12 or 24-port module panels ■■ VarioLine® Modular system peripherals on the patch side Cover can be removed/mounted on the tertiary cable side without the use of tools ■■ Potential equalisation possible (drilled hole diam. 5 mm) ■■ The housing can be attached using screws or nailed dowels (not included in the scope of delivery) Fig. Designation Configuration Order no. 1 VarioLine® CP6 (1 piece) Consolidation point housing for 6-port module panel LKD 9ZE6 1001 0000 2 VarioLine® CP12 (1 piece) Consolidation point housing for 12-port module panel LKD 9ZE6 1002 0000 3 VarioLine® CP24 (1 piece) Consolidation point housing for 24-port module panel LKD 9ZE6 1003 0000 www.leoni-infrastructure-datacom.com 242 VarioLine®  Module panels with 6, 12, 24 ports for consolidation points VarioLine® CPL12 ELine 12-port module panel can be equipped with ELine 1200® EC7 modules VarioLine® CPL6 ELine EC7 VarioLine® CPL12 ELine EC7 VarioLine® CPL24 ELine EC7 VarioLine® CPL12 VK module 12-port module panel can be equipped with VarioKeystone® modules VarioLine® CPL6 VK module VarioLine® CPL12 VK module VarioLine® CPL24 VK module VarioLine® CPL12 VK LE 12-port module panel can be equipped with VarioKeystone® link extenders VarioLine® CPL6 VK LE VarioLine® CPL12 VK LE VarioLine® CPL24 VK LE Description Module panel made from galvanised steel panel for installation in corresponding CP housing. The module panel is installed in the housing by pushing it into place; can additionally be screwed. ■■ Modules or cable plugs are attached by snapping them in ■■ Can be equipped with 6/12/24 modules depending on the version (see table) Matching modules/ cable plugs ELine 1200® EC7 VarioKeystone® 4K7 VarioKeystone® RJ45 MegaLine® Connect 45 (VarioKeystone® format) VarioKeystone® link extender Module panel CPL6/CPL12/CPL24 ELine for ELine 1200® EC7 modules Module panel CPL6/CPL12/CPL24 VK module for VarioKeystone® modules Module panel CPL6/CPL12/CPL24 VK LE for VarioKeystone® link extender Designation Order no. Designation Designation Order no. VarioLine® CPL6 EC7* LKD 9ZE6 1031 0000 VarioLine® CPL6 VK module* LKD 9ZE6 1011 0000 Order no. VarioLine® CPL6 VK LE* LKD 9ZE6 1021 0000 VarioLine® CPL12 EC7* LKD 9ZE6 1032 0000 VarioLine® CPL12 VK module* LKD 9ZE6 1012 0000 VarioLine® CPL12 VK LE* LKD 9ZE6 1022 0000 VarioLine® CPL24 EC7* LKD 9ZE6 1033 0000 VarioLine® CPL24 VK module* LKD 9ZE6 1013 0000 VarioLine® CPL24 VK LE* LKD 9ZE6 1023 0000 * (1 piece) www.leoni-infrastructure-datacom.com Office Industry DataCenter 243 VarioLine® CPL12 keystone 12-port module panel can be equipped with keystone modules VarioLine® CPL6 keystone VarioLine® CPL12 keystone VarioLine® CPL24 keystone VarioLine® CPL12 SC Duplex 12-port module panel can be equipped with GigaLine® SC Duplex couplings VarioLine® CPL6 SC Duplex VarioLine® CPL12 SC Duplex VarioLine® CPL24 SC Duplex VarioLine® CPL12 LC Duplex 12-port module panel can be equipped with GigaLine® LC Duplex couplings VarioLine® CPL6 LC Duplex VarioLine® CPL12 LC Duplex VarioLine® CPL24 LC Duplex Description Equipped module panels Module panel made from galvanised steel panel for installation CPL SC Duplex and CPL LC Duplex module panels can in corresponding CP housing. be supplied equipped on request. The module panel is installed in the housing by pushing it into place; can additionally be screwed. ■■ Modules are attached by screwing or snapping Can be equipped with 6/12/24 modules depending on the version (see table) Matching couplings MegaLine® Connect45 GigaLine® (keystone) SC Duplex GigaLine® SC Duplex/ST GigaLine® SC Simplex GigaLine® LC Duplex GigaLine® E-2000 Module panel CPL6/CPL12/CPL24 Keystone for MegaLine® Connect45 modules Module panel CPL6/CPL12/CPL24 SC Duplex for GigaLine® couplings Module panel CPL6/CPL12/CPL24 LC Duplex for GigaLine® couplings Designation Order no. Designation Order no. Designation Order no. VarioLine® CPL6 keystone* LKD 9ZE6 1061 0000 VarioLine® CPL6 SC Duplex* LKD 9ZE6 1041 0000 VarioLine® CPL6 LC Duplex* LKD 9ZE6 1051 0000 VarioLine® CPL12 keystone* LKD 9ZE6 1062 0000 VarioLine® CPL12 SC Duplex* LKD 9ZE6 1042 0000 VarioLine® CPL12 LC Duplex* LKD 9ZE6 1052 0000 VarioLine® CPL24 keystone* LKD 9ZE6 1063 0000 VarioLine® CPL24 SC Duplex* LKD 9ZE6 1043 0000 VarioLine® CPL24 LC Duplex* LKD 9ZE6 1053 0000 * (1 piece) www.leoni-infrastructure-datacom.com VarioLine® Modular system peripherals them in (with CPL keystone module panel) ■■ 244 VarioLine®  Floor outlet round/rectangular VarioLine® CPB1 rectangular floor outlet VarioLine® CPB2 round floor outlet Description Description For installation in raised floors. For installation in raised floors. Attached by screwing into the base plate (screws not included Attached by screwing into the base plate (screws not included in the scope of delivery). in the scope of delivery). ■■ Rotatable ■■ Square frame, round cover ■■ Three positions possible ■■ Two positions possible 1. Closed flush with the floor 1. Closed flush with the floor 2. Open 2. Open 3. Open, flush with the floor with strip brush ■■ ■■ RoHS-compliant RoHS-compliant Housing Housing Housing Brushed stainless steel Housing Dimensions 80 mm x 160 mm x 63 mm (H x W x D) Dimensions Brushed stainless steel Open 60 mm x 140 mm x 140 mm (H x W x D) Closed 47 mm x 140 mm x 140 mm (H x W x D) Designation Order no. Designation Order no. VarioLine® CPB1 rectangular floor outlet (1 piece) LKD 9ZE6 1010 0000 VarioLine® CPB2 round floor outlet (1 piece) LKD 9ZE6 1020 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter VarioLine® Modular system peripherals 245 www.leoni-infrastructure-datacom.com 246 www.leoni-infrastructure-datacom.com Office Office Industry DataCenter DataCenter 247 VarioLine®  DC – DataCenter range for holding DClink modules The most notable characteristic of the DataCenter range is that rather than just meeting the current standards and requirements for DataCenters, it actually exceeds them. The quick and easy installation ensures uninterrupted DataCenter operation. The "true" plug and play solution for copper and fiber optic Advantages at a glance: applications consists of a VarioLine® DClink frame (19", 1 RU) ■■ "True" plug and play solution for holding MegaLine® DClink and GigaLine® DClink modules. ■■ Minimal attenuation The DClink modules are simply inserted and audibly clicked ■■ Maximum reliability into place from the rear after the links are installed. ■■ Factory-tested Modules Accessories VarioLine® DClink dummy cover VarioLine® Modular system peripherals GigaLine® DClink module 40/100 GigaLine® DClink module VarioLine® DClink release tool GigaLine® DC MTP module VarioLine® DClink frame, 19" www.leoni-infrastructure-datacom.com Frame 248 VarioLine®  DClink frame 19"/1 RU for holding up to 3 DClink modules Fig. 1 DClink frame 19"/1 RU Fig. 2 DClink dummy cover VarioLine® DClink frame 19"/1 RU VarioLine® DClink dummy cover Description Housing For quick, easy and reliable installation of pre-assembled Housing Powder-coated steel panel DClink modules in DataCenters. Colour Jet black RAL 9005 Unused module openings are closed off with the dummy cover. Dimensions ■■ Can be equipped with GigaLine® and/or MegaLine® DClink 19"/1 RU 44 mm x 483 mm x 175 mm (H x W x D) modules (see DataCenter links from page 230) ■■ For holding up to 3 modules Accessories (optional) Dummy cover For closing off a module opening 42 mm x 133 mm x 39 mm (H x W x D) Matching modules/segments GigaLine® DClink 40/100 Fig. GigaLine® DClink GigaLine® DC MTP module GigaLine® DClink dummy cover Designation Configuration Order no. 1 VarioLine® DClink frame 19"/1 RU (8 pieces) GigaLine® DClink modules LKD 9R00 0005 0000 2 VarioLine® DClink dummy cover (8 pieces) LKD 9R00 0006 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 249 VarioLine®  DataCenter accessories for DClink VarioLine® DClink release tool Description For easy removal of the DClink modules from the DClink frame. Construction Stainless steel Dimensions 65 mm x 40 mm x 4 mm (H x W x D) VarioLine® Modular system peripherals Material Designation Order no. VarioLine® DClink release tool (1 pair) LKD 9R00 0002 0000 www.leoni-infrastructure-datacom.com 250 VarioLine®  DataCenter cable routing panel 19"/1 RU for installing copper or fiber optic patch cords Fig. 1 VarioLine® DC CMP1 with 82 mm metal clips Fig. 2 VarioLine® DC CMP2 with 115 mm metal clips Fig. 3 VarioLine® DC CMP3 with 78 mm plastic clips VarioLine® DC CMP1 with metal clips 82 mm VarioLine® DC CMP2 with metal clips 115 mm VarioLine® DC CMP3 with plastic clips 78 mm Description For reliable installation of fiber optic and copper patch cords in the distribution cabinet. With metal or plastic clips depending on the model. Construction Panel Powder-coated steel panel Colours Light grey RAL 9005/Jet black RAL 9005 Dimensions DC CMP1 44 mm x 483 mm x 95 mm (H x W x D) DC CMP2 44 mm x 483 mm x 127 mm (H x W x D) DC CMP3 44 mm x 483 mm x 90 mm (H x W x D) Fig. Designation Colour Order no. 1 VarioLine® DC CMP1 with 82 mm metal clips (1 piece) Jet black RAL 9005 LKD 9ZE3 0050 0000 – VarioLine® DC CMP1 with 82 mm metal clips (1 piece) 2 VarioLine® DC CMP2 with 115 mm metal clips (1 piece) 3 VarioLine® DC CMP3 with 78 mm plastic clips (1 piece) LKD 9ZE1 0006 0000 Light grey RAL 7035 LKD 9A61 0028 0000 LKD 9A61 0020 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter VarioLine® Modular system peripherals 251 www.leoni-infrastructure-datacom.com 252 www.leoni-infrastructure-datacom.com Office Industry DataCenter 253 VarioLine®  UF – underfloor systems Mounting plate solution – modular and universal The "VarioLine® UF" underfloor systems (floorbox solutions) The mounting plate replaces the equipment rack, offering offer an efficient and cost-effective solution for terminating maximum space for the cable feed. The tilted feed-in and feed-out copper and fiber optic systems. guarantees secure cable routing, even with very low raised floors. They offer a high degree of flexibility in the office environment. Adapter plates allow cost-effective and efficient installation Desks can be connected to the power and IT network without of all LEONI connectivity components, whether copper or fiber the usual jumble of cables. The modular and universal mounting optic. plate solutions are available for all common underfloor systems VarioLine® Modular system peripherals (e.g. Ackermann or Electraplan). Example of an underfloor solution from LEONI in an Ackermann floorbox www.leoni-infrastructure-datacom.com 254 VarioLine®  UF – underfloor systems/floorbox solutions System overview – based on VarioKeystone®/ELine 1200® EC7/keystone modules VarioKeystone® 4K7 VarioKeystone® RJ45 MegaLine®Connect45 (in VarioKeystone® format) VarioLine® UF AP3 for up to 3 VarioKeystone® modules or for up to 3 MegaLine® Connect45 modules (in VarioKeystone® format) VarioKeystone® double module RJ45 MegaLine®Connect45 (in VarioKeystone® format) VarioLine® UF APD1 for 1 VarioKeystone® double module for up to 2 MegaLine® Connect45 modules (in VarioKeystone® format) VarioLine® UF AP3 EC7 for up to 3 ELine 1200® EC7 modules ELine 1200® EC7 VarioLine® UF APD3 for up to 3 MegaLine® Connect45 modules (in keystone format) MegaLine®Connect45 (in keystone format) Jack Adapter plate www.leoni-infrastructure-datacom.com Office Industry DataCenter 255 VarioLine® UF TA2 for Ackermann GES 2, 4, 6, R4, R7 VarioLine® Modular system peripherals VarioLine® UF TA3 for Ackermann GES 9, R7, R9 VarioLine® UF TEK3 for Electraplan KDR series (old type) VarioLine® UF TEV3 for Electraplan VQ12, VR12, VR10 Mounting plate www.leoni-infrastructure-datacom.com 256 System overview – based on GigaLine®  couplings GigaLine® SC Duplex Dummy cover for VarioLine® UF mounting plates VarioLine® UF TA2 for Ackermann GES 2, 4, 6, R4, R7 VarioLine® UF AP4-SCD for up to 4 couplings GigaLine® SC Duplex/ST VarioLine® UF TA3 for Ackermann GES 9, R7, R9 GigaLine® SC Simplex GigaLine® LC Duplex VarioLine® UF AP4-LCD for up to 4 couplings VarioLine® UF TEK3 for Electraplan KDR series (old type) GigaLine® E-2000 VarioLine® UF TEV3 for Electraplan VQ12, VR12, VR10 Jacks Adapter plate Mounting plate www.leoni-infrastructure-datacom.com Office Industry DataCenter 257 VarioLine® UF O2 for mounting plates T2 VarioLine® UF-SC2 for excess-length module UM2 VarioLine® UF O3 for mounting plates T3 VarioLine® UF-SC3 for excess-length module UM3 VarioLine® Modular system peripherals VarioLine® UF K1 VarioLine® UF K2 Strain relief www.leoni-infrastructure-datacom.com Excess-length module Splice tray 258 VarioLine®  Mounting plates for underfloor systems For installing wall outlets Fig. 1 Mounting plate VarioLine® UF TOA2-2 For Ackermann GES 2, 4, 6, R4, R7 Fig. 2 Mounting plate VarioLine® UF TOA3-2 For Ackermann GES 9, R7, R9 Fig. 3 Mounting plate VarioLine® UF TOA3-3 For Ackermann GES 9, R7, R9 VarioLine® UF TOA2-2/UF TOA3-2 VarioLine® UF TOA3-3 Description Description UF TOA2-2 ➔ for mounting up to 2 wall outlets with 50 mm x For mounting up to 3 wall outlets with 50 mm x 50 mm 50 mm central plate and lateral attachment or one wall outlet central plate and lateral fastening or two wall outlets with with circumferential ring. circumferential ring. ■■ For installation in Ackermann device inserts UF TOA3-2 ➔ for mounting up to 2 wall outlets with 50 mm x 50 mm central plate and lateral attachment or two wall outlets Housing with circumferential ring. Mounting plate Powder-coated steel panel, 1.5 mm Colour Jet black RAL 9005 ■■ For installation in Ackermann device inserts Housing Accessories (optional) see from page 262 Mounting plate Powder-coated steel panel, 1.5 mm Cable retainer VarioLine® UF K1/VarioLine® UF K2 adjustable Colour Jet black RAL 9005 cable strain relief for up to 9 individual cables Accessories (optional) see from page 262 Cable retainer for VarioLine® UF K1/VarioLine® UF K2 Adjustable cable strain relief for up to 9 individual cables Fig. Designation Order no. 1 VarioLine® UF TOA2-2 (1 piece) LKD 9ZE6 0014 0000 2 VarioLine® UF TOA3-2 (1 piece) LKD 9ZE6 0012 0000 Fig. 3 Designation Order no. VarioLine® UF TOA3-3 (1 piece) LKD 9ZE6 0013 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 259 VarioLine®  Mounting plates for underfloor systems for installing adapter panels Fig. 1 Mounting plate VarioLine® UF TA2 for Ackermann GES 2, 4, 6, R4, R7 Fig. 2 Mounting plate VarioLine® UF TA3 for Ackermann GES 9, R7, R9 Fig. 1 Mounting plate VarioLine® UF TEK3 for Electraplan KDR series (old type) VarioLine® UF TA2/UF TA3 Fig. 2 Mounting plate VarioLine® UF TEV3 for Electraplan VQ12, VR12, VR10 VarioLine® UF TEK3/UF TEV3 Description Description For mounting up to 2 or 3 adapter plates. For mounting up to 3 adapter plates. For installation in Ackermann device inserts ■■ Compatibility For installation in Electraplan device inserts Compatibility UF TA2 Ackermann GES 2, 4, 6, R4, R7 UF TEK3 Electraplan KDR series (old type) UF TA3 Ackermann GES 9, R7, R9 UF TEV3 Electraplan VQ12, VR12, VR10 Housing Housing Mounting plate powder-coated steel panel, 1.5 mm Mounting plate powder-coated steel panel, 1.5 mm Colour Jet black RAL 9005 Colour Jet black RAL 9005 Accessories (optional) see page 263 Accessories (optional) see page 263 Cable retainer for VarioLine® UF K1/VarioLine® UF K2 Adjustable Cable retainer VarioLine® UF K1/VarioLine® UF K2 adjustable cable strain relief for up to 9 individual cables cable strain relief for up to 9 individual cables Fig. Designation Order no. 1 VarioLine® UF TA2 (1 piece) LKD 9ZE6 0001 0000 2 VarioLine® UF TA3 (1 piece) LKD 9ZE6 0002 0000 www.leoni-infrastructure-datacom.com Fig. Designation Order no. 1 VarioLine® UF TEK3 (1 piece) LKD 9ZE6 0008 0000 2 VarioLine® UF TEV3 (1 piece) LKD 9ZE6 0042 0000 VarioLine® Modular system peripherals ■■ 260 VarioLine®  Adapter panels for underfloor systems for installation in VarioLine® UF mounting plates Fig. 1 Adapter panel VarioLine® UF APD1 VK For 1 VarioKeystone® double module or up to 2 MegaLine® Connect45 modules (VarioKeystone) Fig. 2 Adapter panel VarioLine® UF AP3 VK For up to 3 VarioKeystone® modules or up to 3 MegaLine® Connect45 modules (VarioKeystone) VarioLine® UF APD1 VK VarioLine® UF AP3 VK VarioLine® UF AP3 MC45 Description Compatibility Adapter panel for installation in VarioLine® UF mounting plates. UF APD1 VK For installing up to 3 modules. Fig. 3 Adapter panel VarioLine® UF AP3 MC45 For up to 3 MegaLine® Connect45 modules (keystone) ➔ For 1 VarioKeystone® double module or up to 2 MegaLine® Connect45 modules ■■ With self-adhesive labels for personal labelling ■■ 2 nut-and-washer assemblies included (VarioKeystone®) UF AP3 VK ➔ For up to 3 VarioKeystone® modules or up to 3 MegaLine® Connect45 modules (VarioKeystone®) UF AP3 MC45 ➔ For up to 3 MegaLine® Connect45 modules (keystone) Construction Matching jacks VarioKeystone® 4K7 VarioKeystone® RJ45 Adapter panel Powder-coated steel panel, 1.5 mm Surface Zn – black, conductive VarioKeystone® Double module RJ45 MegaLine® Connect45 (VarioKeystone) MegaLine® Connect45 (keystone) VarioLine® UF APD1 VK VarioLine® UF AP3 VK VarioLine® UF AP3 MC45 Fig. 1 Designation Order no. VarioLine® UF APD1 VK (1 piece) LKD 9ZE6 0040 0000 2 VarioLine® UF AP3 VK (1 piece) LKD 9A46 0118 0000 3 VarioLine® UF AP3 MC45 (1 piece) LKD 9ZE6 0044 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 261 Fig. 1 Adapter panel VarioLine® UF AP3 ELine For up to 3 ELine 1200® EC7 modules Fig. 2 Adapter panel VarioLine® UF AP4 SCD For up to 4 SC Duplex couplings VarioLine® UF AP3 EC7 Fig. 3 Adapter panel VarioLine® UF AP4 LCD For up to 4 LC Duplex couplings VarioLine® UF AP4-SCD/UF AP4-LCD Description Description Adapter panel for installation in VarioLine® UF mounting plates. Adapter panel for installation in VarioLine® UF mounting plates. For installing up to 3 ELine 1200® EC7 modules. For installing up to 4 SC or LC Duplex couplings. ■■ With earth or ground connection ■■ With self-adhesive labels for personal labelling ■■ With self-adhesive labels for personal labelling ■■ 2 nut-and-washer assemblies included ■■ 2 nut-and-washer assemblies included Compatibility UF AP4-SCD Adapter panel Steel panel, 1.5 mm Surface Aluminium zinc For up to 4 SC Duplex or SC Duplex/ ST couplings UF AP4-LCD For up to 4 LC Duplex, SC Simplex or E-2000 couplings Construction Matching jacks ELine 1200® EC7 GigaLine® SC Duplex Adapter panel Powder-coated steel panel, 1.5 mm Surface ZN – black, conductive GigaLine® SC Duplex/ST GigaLine® SC Simplex GigaLine® LC Duplex GigaLine® E-2000 VarioLine® UF AP3 EC7 VarioLine® UF AP4 SCD VarioLine® UF AP4 LCD Fig. 1 Designation Order no. VarioLine® UF AP3 EC7 (1 piece) LKD 9ZE6 0006 0000 www.leoni-infrastructure-datacom.com Fig. Designation Order no. 2 VarioLine® UF AP4-SCD (1 piece) LKD 9FZZ 0078 0000 3 VarioLine® UF AP4-LCD (1 piece) LKD 9FZZ 0079 0000 VarioLine® Modular system peripherals Construction 262 VarioLine®  Excess-length module VarioLine®  Splice tray for underfloor systems for underfloor systems Fig. 1 Excess-length module for mounting plates T2 Fig. 3 Splice tray for excess-length module UM2 Fig. 2 Excess-length module for mounting plates T3 VarioLine® UF O2 VarioLine® UF O3 Fig. 4 Splice tray for excess-length module UM3 VarioLine® UF SC2 VarioLine® UF SC3 Description Description Excess-length module for mounting on VarioLine®UF mounting Splice tray with cover and splice holder for 12 crimp splices. plates. Can be mounted without the use of tools. For mounting on the underside of the corresponding excesslength module. Compatibility/dimensions (available in two sizes) Compatibility/dimensions (available in two sizes) UF O2 UF SC2 For mounting plates T2 61 mm x 75 mm x 135 mm (H x W x D) UF O3 10 mm x 75 mm x 113 mm (H x W x D) UF SC3 For mounting plates T3 For excess-length module UM2 61 mm x 75 mm x 176 mm (H x W x D) For excess-length module UM3 10 mm x 75 mm x 154 mm (H x W x D) Housing Housing Excess-length module Powder-coated steel panel, 1.5 mm Splice tray Powder-coated steel panel, 1.5 mm Colour Colour Jet black RAL 9005 Jet black RAL 9005 Accessories (optional) see page 263 A cable retainer is required for mounting the excess-length module Fig. Designation Order no. 1 VarioLine® UF O2 (1 piece) LKD 9FZZ 0080 0000 2 VarioLine® UF O3 (1 piece) LKD 9FZZ 0018 0000 Fig. Designation Order no. 3 VarioLine® UF SC2 (1 piece) LKD 9FZZ 0020 0000 4 VarioLine® UF SC3 (1 piece) LKD 9FZZ 0081 0000 www.leoni-infrastructure-datacom.com Office Industry DataCenter 263 VarioLine®  Cable retainer VarioLine®  Dummy cover for underfloor systems for VarioLine® UF mounting plates Fig. 3 Dummy cover UF mounting plates Fig. 2 Cable retainer depth 64.5 mm Fig. 1 Cable retainer depth 45 mm VarioLine® UF K1 VarioLine® UF K2 Fig. 4 Dummy cover UF mounting plates for wall outlet inserts VarioLine® UF BP-T VarioLine® UF BP-TO Description Description Cable retainer for attachment to VarioLine® UF mounting plates. Blind cover for closing off an unused opening in the VarioLine® UF mounting plate. 2 nut-and-washer assemblies included Compatibility/dimensions (available in two sizes) Compatibility UF K1 Depth 45 mm UF BP-T For VarioLine® UF mounting plates 61 mm x 72 mm x 45 mm (H x W x D) UF BP-TO For VarioLine® UF mounting plates UF K2 Depth 64.5 mm For wall outlet inserts 61 mm x 72 mm x 64.5 mm (H x W x D) Housing Housing Strain relief Powder-coated steel panel, 1.5 mm Colour Jet black RAL 9005 Fig. Mounting plate Powder-coated steel panel, 1.5 mm Colour Jet black RAL 9005 Designation Order no. 1 VarioLine® UF K1 (1 piece) LKD 9ZE6 0003 0000 3 VarioLine® UF BP-T (1 piece) LKD 9ZE6 0005 0000 2 VarioLine® UF K2 (1 piece) LKD 9ZE6 0004 0000 4 VarioLine® UF BP-TO (1 piece) LKD 9ZE6 0015 0000 www.leoni-infrastructure-datacom.com Fig. Designation Order no. VarioLine® Modular system peripherals ■■ 264 Field of application Office www.leoni-infrastructure-datacom.com Office Industry DataCenter 265 Generic cabling in office buildings The complete cable system, from distribution equipment to workstation ISO/IEC 11801 and EN 50173-2 ISO/IEC 24702 and EN 50173-3 ISO/IEC 15018 and EN 50173-4 ISO/IEC 24764 and EN 50173-5 Information technology Information technology Information technology Information technology Generic communication cable systems Generic communication cable systems Generic communication cable systems Generic communication cable systems Office buildings Industry Apartments DataCenters ISO/IEC 11801 and EN 50173-1 Information technology Generic communication cable systems General requirements These days, the future of a company depends to a large The smart use of fiber optics and copper data technologies for extent on reliable and timely data processing. the backbone and horizontal wiring to the user enables costeffective networking of standard resources such as PCs and The rapid development of data bit rates and the wide range of printers, with an extension to IP telephony and multimedia applications require a very flexible, high-performance network applications. Other applications, such as Power-over-Ethernet infrastructure that will be able to meet the demands for the (PoE), support the powering of devices such as web cameras, next ten years. wireless LAN access points, IP phones and laptops via the copper data cabling. High-quality generic IT networks form the backbone of the business in research & development, banks, insurance These structured, generic communication cable systems meet companies, universities, hospitals, hotels, airports and many both the international and European standards set by ISO/IEC other sectors, providing smooth operation and financial success. 11801 and DIN EN 50173-1/2 respectively. CD Campus distributor EI Building distributor FD Floor distributor CP Consolidation point TO Telecommunications outlet TE Terminal equipment www.leoni-infrastructure-datacom.com CD EI FD CP Subsystem of Subsystem the primary of the Subsystem of the tertiary cabling secondary cabling system system cabling system Generic communication cable system TO TE Equipment connection cabling system Fields of application Structure of a generic communication cable system  ISO/IEC 11801 and DIN EN 50173-1/2 Field of application Industry www.leoni-infrastructure-datacom.com Industry Office DataCenter 267 Generic cabling in the industrial environment ISO/IEC 11801 and EN 50173-2 ISO/IEC 24702 and EN 50173-3 ISO/IEC 15018 and EN 50173-4 ISO/IEC 24764 and EN 50173-5 Information technology Information technology Information technology Information technology Generic communication cable systems Generic communication cable systems Generic communication cable systems Generic communication cable systems Office buildings Industry Apartments DataCenters ISO/IEC 11801 and EN 50173-1 Information technology Generic communication cable systems General requirements Office/IP20 ID TO NI Office/IP20 IP67 Structure of a generic communication cable system in industrial facilities ISO/IEC 24702 and EN 50173-3 www.leoni-infrastructure-datacom.com Automation island Fields of application FD/ID IP67 268 Industrial IT cabling Uniform IT platforms are increasingly used to connect different worlds The worlds of office and industrial cabling are growing ever A consistent extension of the use of generic closer. The need for sales departments to receive current cabling offers enormous advantages, including: production data or to engage in short-term planning ■■ Reduction in the assortment of products of production processes requires a uniform group-wide ■■ Deployment and distribution of mass-produced products IT platform. ■■ Standardisation of acceptance measurements ■■ Reduction in training costs Manufacturers of automation and control equipment demand ■■ Easy trouble-shooting consistent, future-proofed international standards, while users ■■ Simplification of the network operation, maintenance and are looking for secure investments. Ever more applications in documentation production processes are implemented via Ethernet, reducing maintenance and operating costs. Existing standards and It is frequently observed these days that the transmission applications, such as PROFINET, will still need support in the requirements in industrial environments are less challenging years to come. than those in the office area. This can lead to a reduction in costs without risking the future requirements of the network. This results in a requirement for a clear separation between Since cable laying is expensive, and an expansion of technical "application" and "network", which can only be achieved requirements would lead to unnecessary additional costs, using a uniform IT platform as a base, combined with generic we recommend that data cables should be selected to meet communication cabling, in both the office and manufacturing the highest standards (Category 7 or above). environments. This requirement has been standardised in the EN 50173-1, -2, -3 series, and in the ISO/IEC11801 and ISO/IEC The connectivity can certainly be limited to the level currently 24702 international standards. required, if the equipment used can be adapted cleverly to meet changing requirements in both transmission rates and building or manufacturing construction. This balancing act is easily manageable using the VarioKeystone® connection system from LEONI. www.leoni-infrastructure-datacom.com Industry Office DataCenter 269 MICE concept Classification of environmental conditions MICE Requirement/level Requirement/level Requirement/level 1 2 3 M Mechanical M1 M2 M3 I Ingress I1 I2 I3 C Climatic/chemical C1 C2 C3 E Electromagnetic E1 E2 E3 The environmental factor The MICE classification can vary over the length of the As well as the electrical or optical transmission channel, transmission link, for example mechanical loads in the office the different conditions in office and industrial settings mean environment are fairly low and the ingress of liquids or that the environmental factor also plays an important role. significant climatic and chemical loads are equally unlikely. The conditions in buildings used for industrial purposes, These environmental conditions are described using four on the other hand, are harsher: basic characteristics: Mechanical Mechanical properties Mechanical loads as well as the risk of ingress of dust, dirt and Ingress Ingress properties liquids; high, quickly changing temperatures; solar radiation and Climatic/chemical Climatic and chemical properties corrosive substances can affect the components. Electromagnetic Electromagnetic interference also influences the data communication. Electromagnetic properties The four MICE criteria are broken down into different M1 I1 C1 E1 MICE 2 2 1 1 Telecommunications room Factory floor M1 I2 C3 E2 M 3 I3 C 3 E 3 Automation area Automation island more stringent the requirements: ■■ Office environment M1 / I1 / C1 / E1 ■■ Factory environment (light duty) M2 / I2 / C2 / E2 ■■ Machine environment (heavy duty) M3 / I3 / C3 / E3 Distributor www.leoni-infrastructure-datacom.com Cabling channel Fields of application parameters, each with three levels. The higher the level, the 270 Industrial IT cabling VarioKeystone® connectivity The VarioKeystone® system from LEONI Kerpen offers a VarioKeystone® – One click takes you to the next generation flexible connection concept with an extremely secure future. The high-quality components allow transmission links exceeding the requirements of Class E to be established. ■■ Outstanding performance The modular structure makes it possible to change the plug face from RJ45 to Tera with little effort if required. It is not necessary ■■ Just change the plug for a new interface to reinstall the data outlets for this purpose. ■■ Dispenses with the need to strip wires This makes choosing the required connectivity much easier and opens the door to a future with high data transmission rates. If new mating faces come onto the market in future, it will be possible to adapt to them. VarioKeystone® also offers the unique option of extending or changing a link – this is especially Upward compatibility with VarioKeystone® technology important in the case of cabling systems only designed for a few years of service, for example in the automotive industry. The cable plugs are assembled on site using common tools; the only other thing that is required is a set of parallel press pliers. The jack modules can be pushed onto the cable plugs by hand and removed again if necessary using a simple release tool. Cat. 7 LEONI offers the following for connections in the office environment: ■■ Fixed and telescopic patch panels ■■ Wall outlets ■■ 2-port DIN rail housings ■■ A modular/universal consolidation point range "VarioLine® CP" for 6, 12 and 24 channels Cat. 6A Cat. 5/6 www.leoni-infrastructure-datacom.com Office Industry DataCenter 271 Han® 3A industrial outlets The best choice for use in harsh industrial environments Han® 3A industrial outlets The certified industrial range is being extended for the first The Han® 3A metal outlet can be used for special mechanical time with a high-quality cabling system whose primary loads, in which case the plug connection is held by a latching clip. characteristics are maximum future-proofing and unparalleled flexibility. No matter how adverse the ambient conditions The watertightness of the class IP65/IP67 is also ensured with (i.e. all MICE classes), it signals the end to problems with the matching industrial patch cords. As well as robustness and performance, breaker conditions and new mating faces. abrasion resistance, the construction and PUR sheath of the Han® 3A industrial outlet RJ45 jack module, equipped www.leoni-infrastructure-datacom.com Fields of application flexible cables used also offer exceptional chemical properties. 272 272 Field of application DataCenter www.leoni-infrastructure-datacom.com Office DataCenter Industry 273 Generic cabling in DataCenters ISO/IEC 11801 and EN 50173-2 ISO/IEC 24702 and EN 50173-3 ISO/IEC 15018 and EN 50173-4 ISO/IEC 24764 and EN 50173-5 Information technology Information technology Information technology Information technology Generic communication cable systems Generic communication cable systems Generic communication cable systems Generic communication cable systems Office buildings Industry Apartments DataCenters ISO/IEC 11801 and EN 50173-1 Information technology Generic communication cable systems General requirements The structure The standards The maximum extension is 2,000 metres. In DataCenters the Generic communication cable systems are defined main distribution cabling is frequently designed using fiber in the standards EN 50173-1 and ISO/IEC 11801. optic technology, while in smaller networks the external network interface (ENI) is connected directly to the zone In addition, specific requirements for DataCenters are defined distributor (ZD). The standards describe various models for in EN 50173-5 and ISO/IEC 24764. flexible and fixed connections in and between the subsystems. The cabling used in DataCenters consists of three subsystems: The cabling of the main and zone distribution must, according ■■ Network access cabling to ISO/IEC 24764, meet the requirements of Class EA for copper ■■ Main distribution cabling technology and transmission classes OF-300, OF-500 and ■■ Zone distribution cabling OF-2000 for fiber optic technology as a minimum. ENI External network interface MD Main distributor ZD Zone distributor LDP Local distribution point (optional) EO External network interface EQP Application-specific transmission equipment ENI MD ZD LDP EQP Distributor acc. to EN 50173-1 Main Network distribution access cabling Zone distribution cabling Generic communication cable system www.leoni-infrastructure-datacom.com EO Equipment cabling Fields of application Structure of a generic communication cable system 274 Requirements and solutions Fast – high-quality – cost-optimised DataCenter ➔ High quality The DataCenter, the heart of the business, controls the Quality testing at the factory, performance and safety are production and administrative processes. A failure here can already built into LEONI products. have catastrophic consequences, and the availability of a DataCenter must be therefore guaranteed more or less around ➔ Minimise downtime the clock. The cabling system makes a key contribution to its Installation and commissioning take a very short time, operation reliability. with no need for special tools or assembly skills. This keeps downtime to a minimum. Performance requirements for modern DataCenters Maximum availability, zero downtime ➔ maximum reliability ➔ Cost reduction ■■ Short installation times The use of GigaLine® DClink results Costs per link* ■■ Maximum performance in cost savings of up to 55 % in 100 % ■■ Minimal space requirement – high packing density comparison with traditional modular ■■ Cost efficiency systems using MPO connection ■■ Environmental compatibility – Green IT technology. separately. For example, optimising the environmental performance will lead to a reduction in costs. Investing in industrially pre-assembled components is usually associated with higher costs, but enables installation and testing times to be reduced, thus reducing the cost associated with downtime. 45 % DClink The diverse requirements for DataCenters cannot be considered Modular solutions with MPO ■■ * Example: Link length: 30 m, fibers: 24 x OS2e, plugs: LC Duplex www.leoni-infrastructure-datacom.com Office Industry DataCenter 275 The advantages Exceed all requirements with LEONI Giga Meg Giga Va r i oLin aLin Line ® Line ® D Clin k e DC link ® D Cf le x e ® CP LEONI can offer a range of high-quality products that go well beyond the current standards and requirements for data centers. ■■ An EC7 plug and the corresponding cable delivers performance far exceeding Class FA ■■ Fiber optic cable systems constructed using LEONI cables The Installation Ecologically aware cabling Plug and play solutions for copper and fiber optic applications Environmentally sound materials and production methods, consist of pre-assembled links and the VarioLine® DClink the possibility of recycling or ecologically viable recovery frame (19", 1 RU) for the DClink modules. The DClink modules and, last but not least, the reusability of products if required are simply inserted and clicked into place from the rear after guarantee maximum environmental compatibility. Cables the links are installed. and components are RoHS-compliant. DClink system solutions Optimising attenuation DClink can be used to create fiber optic, copper or mixed A GigaLine® DClink offers up to 70 % Attenuation per link* configurations in various categories. This renders on-site less attenuation than conventional IL = 1.4 dB 100 % connectivity. IL = 0.4 dB > 30 % * Example: Link length: 30 m, fibers: 24 x OS2e, plugs: LC Duplex www.leoni-infrastructure-datacom.com DClink modular systems using MPO removed again using a simple release tool. Modular solutions with MPO assembly completely unnecessary. The modules can be easily Fields of application offer enormous reserves for attenuation and bandwidth 276 Comparison of cabling systems Single cable vs. multi cable Single cables – complex installation and cannot be reused It is not just installing new cables that is difficult and timeconsuming, but also removing the old cables. The only options are either to cut them out or simply leave them where they are. This means that there is no practical way of reusing them and they are not recycled. The disorganised way in which the cables are installed obstructs the flow of cooling air. Only a higher volumetric flow rate and/or a lower air temperature can help here. Both mean higher costs and increased environmental impact. www.leoni-infrastructure-datacom.com Office Industry DataCenter 277 Multi cables – quick and clean installation and can be reused at any time Pre-assembled multi cable solutions ensure a clean and clear cabling layout in the raised floor. As well as making installation easier and therefore quicker, this also helps to improve cooling air circulation. Cables and components are RoHS-compliant. The low volume of the installed multi cables guarantees an Fields of application unobstructed flow of cooling air and therefore uses less energy. www.leoni-infrastructure-datacom.com 278 Index Introduction 2 Cable plugs 80 Portfolio 2 Jack modules 81 Contents 3 Double modules RJ45 82 Welcome to the datacom mega store for cable and system solutions 4 Link extenders 83 The LEONI Group 6 Telephone patch panel 83 Infrastructure & Datacom Business Unit 7 Patch panel 19" 84 Quality and environmental management 8 Modular patch panels 19"/1 RU 85 86 Industrial patch cord RJ45/RJ45 Cat. 6/500 MHz 125 Patch cord TERATM 126 Patch cord and connection cable EC7, 4 pairs 128 Patch cord and connection cable EC7, 2 pairs 129 Patch cord and connection cable EC7, 1 pair, shielded 130 Patch cord and connection cable EC7, 1 pair/2 pairs, shielded 131 Trunk cable 132 MegaLine® Cu data cables 10 Modular patch panels 19"/1 RU for link extenders SPACE concept 12 DIN rail housing 87 Trunk cable, industrial 133 SPACE- Security 13 Industrial housing IP44 88 Trunk cable, 8-port RJ45 134 SPACE - Performance 14 Industrial housing IP65/67 88 Trunk cable, 4-port/8-port 135 SPACE - Application 16 89 SPACE - Construction 17 Wall outlets for VarioKeystone® jack modules MegaLine® Connect45 trunk cable with jack modules Cat. 6A/Cat. 6A 136 SPACE - EMC 18 VarioKeystone® accessories 90 MegaLine® Connect45 trunk cable, 8-port 137 Cable assembly tools 91 CP cable 138 EC7 CP cable 139 Patch accessories 140 Type codes 19 Cable types 20 MegaLine® Connect 45 Cu connectivity 92 MegaLine® G12-150 S/F 22 Connectivity can be so easy 94 MegaLine® F10-130 S/F 24 LEO (Light Emitting Outlet) 95 MegaLine® F10-115 S/F 26 System overview 96 MegaLine® F6-90 S/F 28 Cable plugs 98 MegaLine® F6-80 S/F 30 Jack modules in VarioKeystone® format 99 MegaLine® E5-70 S/F 32 Jack modules in keystone format 100 MegaLine® E5-70 F/F 34 Patch panels 19"/1 RU 101 MegaLine® E5-60 U/F 36 Wall outlets 102 MegaLine® E2-45 U/F 38 Accessories & tools 103 MegaLine® E2-30 F/U 40 ELine 1200® EC7 Cu connectivity 104 The passive cabling system for multimedia applications 106 System overview 108 EC7 jack and accessories 110 Wall outlet insert 111 EC7 patch panel 112 EC7 accessories MegaLine® E2-30 U/U 42 MegaLine® D1-20 SF/U 44 MegaLine® F10-120 S/F flex 46 MegaLine® F6-90 S/F flex 48 MegaLine® D1-20 SF/U flex 50 MegaLine® F10-130 S/F (L)2Y 52 MegaLine® F10-130 S/F QH 54 MegaLine® F10-130 S/F Vö 56 MegaLine® F10-115 S/F V 58 MegaLine® F6-90 S/F 2Y 60 MegaLine® D1-20 SF/U 2Y 62 MegaLine® D1-20 SF/U HQH 64 MegaLine® F10-120 S/F 11Y flex 66 MegaLine® F6-70 S/F 11Y flex 68 MegaLine® D1-20 S/U 11Y superflex 70 VarioKeystone® Cu connectivity 72 The innovative connection concept 74 One click takes you to the next generation 75 Benefits that speak for themselves 76 No limits 77 System overview 78 ® Test report 141 MegaLine® Acceptance measurement 142 Acceptance measurement 143 Channel 144 Permanent link 145 Acceptance measurement Class EA 146 Acceptance measurement Class F 147 Acceptance measurement Class FA 148 Alien crosstalk 150 GigaLine® FO data cables 152 The fiber 154 For LAN, WAN and SAN 157 Fiber qualities 158 Colour codes 159 Type codes 160 112 Cable sheath material for fiber optic cables 161 Patch panel 19" with 24/48 ports 113 Rodent protection for fiber optic cables 162 EC7 mini patch panel with 6 ports 114 Pictograms 163 EC7 mounting tool 114 Handling and safety notices 164 EC7 measuring equipment 115 GigaLine® indoor cable, duplex fig 8 165 MegaLine® Cu patch cords/ trunk cables 116 GigaLine® indoor cable, duplex fig 0 166 Patch cord RJ45/RJ45 Cat. 5/100 MHz 118 GigaLine® indoor cable, mini breakout 167 Patch cord RJ45/RJ45 Cat. 6/250 MHz 119 GigaLine® breakout cable 168 Patch cord RJ45/RJ45 Cat. 6/500 MHz 120 169 Patch cord RJ45/RJ45 Cat. 6A/500 MHz 121 GigaLine® universal cable, mini breakout 800 N LED patch cord RJ45/RJ45 GigaLine® universal cable, central 2500 N 170 122 Industrial patch cord RJ45/RJ45 Industrial patch cord with Han® 3A plugs Cat. 6/500 MHz Cat. 5/100 MHz Cat. 6/Class E 123 GigaLine® universal cable, stranded 4000 N 171 GigaLine® universal cable, central 2500 N 172 LEONI "fire secured" fiber optic data cables 173 124 www.leoni-infrastructure-datacom.com 279 LEONI news VarioLine® Modular system peripherals 236 VarioLine® CP – Consolidation point range 238 Consolidation point housing, 6-port 240 177 Consolidation point housing, for 6, 12, 24-port module panels 241 178 Module panels with 6, 12, 24 ports 242 GigaLine® outdoor cable, stranded 4000 N 179 Floor outlet, round/rectangular 244 To request a copy of LEONInews, simply send an GigaLine® outdoor cable, stranded 180 VarioLine® DC – DataCenter range 246 e-mail to: [email protected] GigaLine® FO connectivity 182 DClink frame 19"/1 RU 248 Fiber optic cabling systems 184 DataCenter accessories 249 GigaLine® Trunk and splice boxes 186 DataCenter cable routing panel 19"/1 RU 250 Fiber optic trunk box 188 VarioLine® UF – Underfloor systems 252 Fiber optic trunk box, telescopic 190 System overview 254 Fiber optic splice box, fixed 192 258 GigaLine® Compact – FO distribution system Mounting plates for underfloor systems for mounting wall outlets 194 259 Compact fiber optic rack 196 Mounting plates for underfloor systems for mounting adapter plates Compact fiber optic module 197 Adapter plates for underfloor systems 260 Compact fiber optic module, for splicing solutions Excess-length module 262 198 Splice tray 262 GigaLine® Office and floor distributor 201 Cable retainer 263 Office and floor distributors 202 Dummy cover 263 Office field of application 264 GigaLine® "fire secured" universal cable, central with CI, 90 min total system integrity 174 GigaLine® "fire secured" universal cable, central with CI, 120 min total system integrity 175 GigaLine® outdoor cable, central 1750 N 176 GigaLine® outdoor cable, stranded 4000 N GigaLine® outdoor cable, central 1750 N GigaLine® Fiber-To-The-Desk (FTTD) wall outlets 205 Our regularly updated information services such as the LEONI newsletter keep you abreast of recent developments at LEONI and on the market. Generic cabling in office buildings 265 206 Industry field of application 266 FTTD wall outlets cable reservoir/splice tray 207 Generic cabling in industrial setting 267 FTTD outlet for cable ducts 208 Industrial IT cabling 268 FTTD mounting bracket for cable ducts 209 MICE concept 269 GigaLine® FO patch cords/trunk cables 210 Industrial IT cabling 270 Fiber optic patch cord, breakout 212 Fiber optic patch cord, MiniZip 214 Fiber optic patch cord, LC/PC Uniboot 215 Fiber optic patch cord, MTP 216 GigaLine® Trunk – pre-assembled trunk cables 219 Fiber optic trunk cable, mini breakout 220 Fiber optic trunk cable, breakout 222 Fiber optic trunk cable, outdoor 224 Visit our homepage: Fiber optic trunk cable, universal 226 www.leoni-infrastructure-datacom.com GigaLine® DataCenter links 228 DataCenter links 230 Here you will find the latest information DataCenter link up to 100 Gbit/s 231 ■■ Product and company news DataCenter link 232 ■■ Specialist articles DataCenter link MTP module 233 ■■ Trade fairs, seminars and roadshows GigaLine® Acceptance measurement 234 ■■ Acceptance measurement 235 Announcement texts ■■ Standardisations/certification programmes FTTD wall outlets for surface/flush mounting www.leoni-infrastructure-datacom.com Han® 3A industrial outlets 271 DataCenter field of application 272 Generic cabling in DataCenters 273 Requirements and solutions 274 The benefits 275 Comparison of cabling systems 276 Find out more: Business Unit Infrastructure & Datacom [email protected] www.leoni-infrastructure-datacom.com LEONI Kerpen GmbH LEONI Studer AG Zweifaller Strasse 275–287 Herrenmattstrasse 20 52224 Stolberg 4658 Däniken Germany Switzerland Telephone +49 (0) 2402 17 1 Telephone +41 (0) 62 288 82 82 Telefax Telefax +49 (0) 2402 75154 +41 (0) 62 288 83 83