Preview only show first 10 pages with watermark. For full document please download

Meitav-tec Catalogue Europe

   EMBED


Share

Transcript

EURO 2016 Table of Contents A Company Overview 1 On-Off Thermostats 2 On-Off Thermostats – Programmable 3 Proportional Thermostats 4 Humidity Controllers 5 Fan Coil – Stand Alone Controllers 6 A/C Stand-Alone Controllers 7 Maxinet – Thermostat Network 8 Communication / B.M.S. 9 Multi Zone Systems 10 Dampers ___________________________________________ __________________________________________ ______________________ ___ __ _______________________________________ __________________________________________ _______________________________ __________________________________ __ 4-x 5-x 6-x 8-x ___________________________________________ 9-x ___________________________________ ______________________________________________ ___________________________________________ 15 Sensors & Accessories 16 Power Supplies 3-x _ _ _ _ _ _ _ _ _ _ _ _ _ _ ___ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 12 Air Quality – GAQ controllers 14 Special Controllers 2-x 7-x _______________________________________________ 13 HVAC Analyzers 1-x __________________________________ ___________________________________________________ 11 Floor Heating A 10-x 11-x 12-x 13-x 14-x _________________________________________ 15-x ________________________________________ ______ 16-x B Types of Products C Contact Us D Product Index ___________________________________________ B ________________________________________________ C _______________________________________________ D Export Catalogue 2010 / P048068 Company Overview Founded in 1989, Meitav-tec is a veteran in the field of HVAC control systems with a reputation of excellence. Our vision and innovation are what set us apart from our competitors and allow us to succeed in this ever–changing industry. We provide intelligent control solutions for all types of HVAC systems for light commercial, residential or apartment applications. Our product range is vast, starting from the simplest of thermostats to the most advanced communication controllers. Our R&D department is always busy forecasting, predicting and creating, in order to ensure Meitav-tec's front line position in a world of constantly evolving technology. Each of our professional engineers boasts years of experience in hardware, software, telecommunications and networks, making them experts in their respective fields. In addition to the standard line of products, Meitav-tec specializes in developing & manufacturing, on a short time period, "tailor-made" products according to customers' specifications and special HVAC control needs. This makes us the obvious choice for all special projects and gives us an advantage among OEM players, a key part of our business. Meitav-tec has a global network of agents, distributors and OEM's in over 25 countries spreading across all 6 continents. Among our customers are many well-known companies, such as Airedale, Belimo, Carrier, Electra, Grüner, Johnson Controls, Sabiana, York and others. Meitav-tec's customers can benefit from caring support services regarding the installation, configuration and operation of its products. Meitav-tec is renowned for its stringent Quality Assurance and product reliability and has been awarded with ISO-9001:2000 Quality certification. Our dedication to quality guarantees product reliability and durability as well as process control and internal quality management. Beyond its first-class products, Meitav-tec endeavors to protect the environment by developing energy saving products. Greenhouse gases, produced, among others, by industrial processes, may excessively raise the temperature of our planet to hazardous levels. Meitav-tec is committed to the environment and fights global warming by designing its thermostats with smart algorithms to save money, save energy and save our planet. www.meitavtec.com A On/Off Thermostats ETN-24-SUPER-SH Wall mount, 24VAC thermostat, Cool/Heat or AC Cool Only configuration, 1 or 3 fan speeds The ETN-24-SUPER-SH thermostat is a fully featured, stylish COOL thermostat suitable for light commercial, residential or apartment applications. It can control a large variety of HVAC systems with different 1/3 configurations. It offers both Cooling Only or Cool & Heat SPEEDS control systems. It also has selectable number of heating and cooling stages and multiple Fan Speeds. The ETN-24-SUPER-SH is an attractive thermostat, with a COMPRESSOR DELAY large, easy to read display. Features EXT. SENSOR OPTION y Wall mount, 24VAC thermostat y Selectable Configuration: Cool/Heat or Cool only y 1 or 3 Fan speeds y y Friendly algorithms and logic y y selectable: * Option B – thermostat will change set point (Economy Mode) Models FAULT INPUT Selectable display – ambient temperature or set temperature only * Option A – thermostat will turn ‘OFF’ C Fault input - To be used with door switch, window contact Input – Normally open – Voltage free with 2 options Model Energy saving – cost efficient, Environmental y Offset – for temperature reading adjustment y Set point limits - password protected y Lock buttons – password protected ALARM LOCK OPT. Wiring diagram Cool Heat Speeds ETN-24-C1-1S-SH 1 N/A 1 ETN-24-C1-3S-SH 1 N/A 3 ETN-24-C2-1S-SH 2 N/A 1 ETN-24-C2-3S-SH 2 N/A 3 ETN-24-C3-1S-SH 3 N/A 1 ETN-24-HC11-1S-SH 1 1 1 ETN-24-HC11-3S-SH 1 1 3 ETN-24-HC12-1S-SH 2 1 1 ETN-24-HC12-3S-SH 2 1 3 ETN-24-HC22-1S-SH 2 2 1 ETN-24-HC23-1S-SH 3 2 1 www.meitavtec.com | [email protected] 1-1 On/Off Thermostats ETN-24-SUPER-SI Wall-mount, 24VAC thermostat, Cool & Heat or Heat Pump- selectable, multiple heating & cooling stages, Auto-Fan selectable, IR option COOL The ETN-24-SUPER-SI thermostat is a fully featured, stylish thermostat, suitable for light commercial, residential or apartment applications. ECONOMY It can control a large variety of HVAC systems with different configurations; both Cool & Heat or Heat Pump HP/HC systems and has a selectable number of heating and cooling stages. The ETN-24-SUPER-SI is an attractive, wall mount thermostat with a large, easy to read display. Features ALARM y 24VAC thermostat y Selectable Configuration: Cool/Heat or Heat Pump y Input – Normally open – Voltage free. To be used y Selectable display – ambient with door switch, window contact, etc. 2 options selectable: temperature or set temperature only y Offset – for temperature reading adjustment * Option B – thermostat will change set point (Economy Mode) y Set point limits password protected y Emergency heat selectable in heat control friendly thermostat Wiring diagram Models 1-2 Cool Heat Speeds ETN-24-HC11-1S-SI 1 1 1 ETN-24-HC22-1S-SI 2 2 1 ETN-24-HC32-1S-SI 2 3 1 ETN-24-HP21-1S-SI 1 2 1 ETN-24-HP32-1S-SI 2 3 1 ETN-24-HP42-1S-SI 2 4 1 www.meitavtec.com | [email protected] LOCK OPT. pump mode y IR option – for hand held remote Energy saving – cost efficient, environmental Model FAULT INPUT y Lock buttons – password protected * Option A – thermostat will turn ‘OFF’ y TIMER RT03 On/Off Thermostats ETN-24-SUPER-SF Wall mount, 24VAC thermostat, H/C or Heat Pump configuration, with Filter counter The ETN-24-SUPER-SF thermostat is a fully featured, COOL stylish thermostat suitable for light commercial, residential or apartment applications. It can control a large variety of HVAC systems with different configurations. It is applicable both for HP/HC Cool/Heat or Heat Pump systems and has a selectable number of heating and cooling stages. The ETN-24-SUPER-SF is an attractive, wall mount thermostat, with large, easy to read display. Features y Wall mount, 24VAC thermostat y Energy saving – cost efficient, environmental friendly thermostat y Cool/Heat or Heat Pump – selectable by choosing ECONOMY y Filter counter in hours- range: 0-900 DIP switch position (adjustable) y Fault Input – Normally open – Voltage freeindication on display only. Turn system Off or y External sensor- option Economy - selectable y Lock – Unlock buttons function y Selectable display – ambient temperature or set TIMER y Emergency heat selectable in heat pump temperature only – selectable by choosing DIP mode ALARM switch position y Multiple heating and cooling stages y Offset – for temperature reading adjustment y IR remote control- option y Set point limits - password protected LOCK OPT. EXT. SENSOR OPTION Wiring diagram Models Model Cooling Stages Heating Stages Fan Speeds Window Contact ETN-HC11-1S 1 1 1 + ETN-HC22-1S 2 2 1 + ETN-HC32-1S 2 3 1 + ETN-HP21-1S 1 2 1 + ETN-HP32-1S 2 3 1 + ETN-HP42-1S 2 4 1 + www.meitavtec.com | [email protected] RT03 1-3 On-0ff Thermostats FMH-220-HP11-3S-IR Flush Mount thermostat, 220VAC, Heat & Cool AC outputs (Heat Pump configuration) with 3 fan speeds and IR The FMH-220-HP11-3S-IR is a fully featured, flushHEAT mount thermostat suitable for commercial or residential applications to control a large variety of HVAC systems. This easy to operate thermostat has one output for Cool and one output for Heat Pump (On/Off), 3 fan AUTO FAN speeds and IR option. The FMH-220-HP11-3S-IR is a smart looking thermostat with a soft aesthetic shape ECONOMY and a large, easy to read LCD display. Features y Flush mount, 230VAC Thermostat COMPRESSOR DELAY friendly thermostat y Heat Pump configuration TIMER y Daily digital timer – optimal when you are a y 3 Fan Speeds way or asleep (from Remote Control) y Auto fan- selectable y 3-minute compressor delay y Auto speed - selectable y Temperature offset – adjustable y Remote Control – option Wiring diagram HE Heat Pump (0.5A) RE Compressor (0.5A) 3 Low 2 Medium 1 High Fan (3A) L Main Input 230VAC N 1-4 y Energy saving – cost efficient, environmental www.meitavtec.com | [email protected] RT03 On-off Thermostats FMH-24-C2-3S-IR Flush Mount Thermostat, 24VAC, Cool only - AC two outputs for Cool, 3 fan speeds and IR option COOL The FMH-24-C2-3S-IR is a fully featured, flush-mount thermostat suitable for commercial or residential applications to control a large variety of HVAC systems. It is targeted for Cool and Fan Only applications and has 2 outputs for Cool and 3 fan speeds. AUTO FAN The FMH-24-C2-3S-IR is a smart looking thermostat with large, easy to read LCD display and a simple user interface. ECONOMY COMPRESSOR DELAY Features y Flush mount, 24VAC thermostat y Remote Control – optional y Cool Only Thermostat, with 2 Cooling stages y Energy saving – operates up to 2 compressors, y Fan modes: Fan on / Auto fan / Auto speed y 2 outputs for Cool y 3 Fan Speeds y Auto fan - selectable y Auto speed - selectable TIMER if needed by smart logic algorithms y 3-minute compressor delay (to protect the RT03 compressor) y Automatic temperature offset y Daily, digital Timer from Remote control – optimal when you are asleep or away Wiring diagram www.meitavtec.com | [email protected] 1-5 On-Off Thermostats FMH-220-HC11-3S-IR Flush Mount, 220VAC thermostat with Heat AC and Cool outputs, 3 fan speeds and IR option The FMH-220-HC11-3S-IR is a fully featured, flushmount thermostat suitable for commercial or residential applications to control a large variety of HVAC systems. This easy to operate thermostat has one output for Cool and one output for Heat Element (On/Off), 3 fan speeds and IR option. The FMH-220-HC11-3S-IR is a smart looking thermostat AUTO FAN with a soft aesthetic shape and a large, easy to read LCD display. Features y Flush mount, 230VAC thermostat y 2 separate outputs for Cool and Heat y 3 Fan Speeds y Remote Control – option y Temperature offset – adjustable y Daily, digital Timer from RC – optimal when you are asleep or away COMPRESSOR DELAY y Energy saving – cost efficient, environmental friendly thermostat y 3 minutes compressor delay 1-6 www.meitavtec.com | [email protected] C (to protect the compressor) y Auto fan – selectable y Auto speed – selectable y Type of heater (electric heater or oil heater) – selectable Wiring diagram TIMER RT03 On/Off Thermostats FMT-24-SUPER AC 24VAC, Flush-mount thermostat, with up to 3 stages for Heat and 2 stages for Cool The FMT24-SUPER thermostat is a flush- mount, stylish thermostat for commercial or residential applications. It has both Heat/Cool and Heat Pump configurations and multiple cooling and heating stages. It offers useful features for cold locations, such as Low Temperature Alarm and Emergency Heat. Overall, the FMT24-SUPER is a sleek, attractive thermostat and a convenient solution for many HVAC systems. AUTO FAN Features y Main input- 24VAC y Economy mode HP/HC y User Selectable applications: y Emergency Heat – compressor stops working; C only Heat Element will be used for Heating * Heat/Cool or Heat Pump F y Low temp. alarm indication – * Electric Heat or Oil/Gas when less than 6°C (45°F) * Heat Pump in Heat or Heat Pump in Cool ALARM y With/without compressor delay y C or F temp. scale display y IR remote control- option y Offset – for temp. reading adjustment ±6°C/F COMPRESSOR DELAY y Temp. limits for Cool & Heat - 10..30°C (50..88°F) Models Cooling Stages Heating Stages Fan Speeds FMT-24-HC11-1S 1 1 1 FMT-24-HC22-1S 2 2 1 FMT-24-HP21-1S 1 2 1 Model FMT-24-HP32-1S FMT-24-SUPER 2 3 1 ALL-IN-ONE ALL-IN-ONE 1 Wiring diagram www.meitavtec.com | [email protected] 1-7 On/Off Thermostats ERT-208 Wall mount, 230VAC thermostat, with 2 compressors - Heat-Pump configuration, 1 fan speed, 12-hour timer and a Remote Control COOL option. The ERT-208 is a fully featured, stylish thermostat suitable for Central Mini-Duct or Split-Unit A/C systems. It has 2 compressors – heat pump configuration with 1 fan speed, 12-hour timer and a remote control option. The ERT-208 is an easy to use thermostat, with a large, easy to read LCD display. COMPRESSOR DELAY Features y Wall-mount, 230VAC thermostat y Temperature set-point limits y 2 compressors, Heat Pump configuration y 12-hour Timer - automatically turns y 1 fan speed y Auto Fan y 3 minute compressor delay for compressor protection y Display of Ambient temperature / Set temperature y Energy saving – cost efficient, environmental friendly thermostat Wiring diagram 1-8 www.meitavtec.com | [email protected] on/off unit within 12-hours C y Option for a Remote Control – (with 24-hour timer) y Large & easy to read LCD display y Comfortable silicon rubber buttons RT03 On/Off Thermostats ERT-209 Wall mount, 230VAC Thermostat, AC with 2 compressors for Cooling and 2 Heat Elements, Timer and IR (option) COOL The ERT-209 is a fully featured thermostat suitable for Central Mini-Duct or Split-Unit AC systems. It has outputs for 2 compressors and 2 Heat Elements – H/C configuration, 1 fan speed, 12-hour timer and a remote control option. The ERT-209 is an easy to use thermostat, with a large, easy to read display. Features ECONOMY y Wall-mount, 230VAC thermostat y 2 compressors for cooling, 2 heat elements for heating y 1 fan speed y 12-hour Timer - automatically turns on/off within 12-hours y Remote Control - optional y Energy saving – cost efficient, environmental friendly thermostat C y 3 minute delay for compressor protection y Heat Off Fan delay RT03 y Ambient temperature display – selectable y Large & easy to read LCD display Wiring diagram www.meitavtec.com | [email protected] 1-9 On-off Thermostats ERT100-LCD-IR AC Wall mount, 230VAC Thermostat, Heat-Pump configuration, 12-hour timer and an option for a Remote Control Unit. COOL The ERT100-LCD-IR is a fully featured thermostat HEAT suitable for central mini-duct or split-unit AC systems. It has heat pump configuration, 3 fan speeds, 12-hour timer and a remote control option. The ERT100-LCD-IR is an easy to use thermostat with a clear, easy to read LCD display. COMPRESSOR DELAY TIMER Features y Wall-mount, 230VAC thermostat y 1 compressor for both Cool and Heat (Heat Energy saving – cost efficient, y Remote Control - optional y 3 fan speeds y Large & easy to read LCD display y Auto Fan - selectable y Comfortable silicon rubber buttons y 3 minute compressor delay y Ambient temperature display y 12-hour Timer - automatically turns the unit Wiring diagram www.meitavtec.com | [email protected] C Environmental Friendly thermostat Pump) on/off within 12-hour 1-10 y (display/hide) - optional ECONOMY On-Off Thermostats TED-220-HP11-3S Wall mount, 220VAC thermostat, with 2 outputs for AC Cool & Heat (Heat Pump), 3 fan speeds and LCD display FC The TED-220-HP11-3S thermostat is suitable for commercial or residential applications to control a large variety of HVAC COOL systems, including fan coils. HEAT This mechanical thermostat offers Cool and Heat outputs as well as 3 fan speeds, making the TED-220-HP11-3S the perfect solution for basic and simple climate control. COMPRESSOR DELAY Features y Wall mount, 220VAC main supply y 2 Outputs for Cool and Heat (HP) y Energy saving – cost efficient, Environmental Friendly logic y Large, easy to read LCD display y 3 Fan Speeds y External sensor – option ECONOMY y Display for ambient temperature and set point EXT. SENSOR OPTION y Compressor delay algorithm Wiring Diagram External sensor (option) T T 3 Fan Low (2.6) 2 Fan Medium (2.6) HE Heat Pump (0.5A) 1 RE Fan High (2.6) Compressor (0.5A) 0 Main Input 230VAC ~ www.meitavtec.com | [email protected] 1-11 On-Off Thermostats TED-220-HC11-3S Wall mount, 220VAC thermostat, with AC temperature display suitable, for fan coil applications and Air Conditions with H/C FC configurations (no Heat Pump). The TED-220-HC11-3S thermostat is suitable for COOL commercial or residential applications to control a large variety of HVAC systems, including fan coils. This mechanical thermostat offers Cool and Heat outputs as well as 3 fan speeds, making the TED220-HC11-3S the perfect solution for basic and simple climate control. Features y Wall mount, 220VAC Main supply y 2 Outputs for Cool and Heat y 3 Fan Speeds y External sensor - option Wiring Diagram 1-12 www.meitavtec.com | [email protected] y Energy saving – cost efficient, Environmental Friendly logic y Large, easy to read LCD display y Display for ambient temperature and set point EXT. SENSOR OPTION On-Off Thermostats TED-24-SUPER Wall-mount, 24VAC thermostat, for both AC applications as well as Fan Coils. AC The TED-24-SUPER thermostat suits commercial or FC residential applications to control a large variety of HVAC systems, including fan coils. COOL This mechanical thermostat offers up to 2 stages for Cool HEAT and 2 stages for Heat, making the TED-24-SUPER the perfect solution for basic and simple climate control. Features y Wall mount, 24VAC thermostat y Heat Pump or Heat/Cool configuration available; jumper selectable AUTO FAN y LCD display for ambient temperature and set point HP/HC y External sensor – option ECONOMY y Suitable for fan coil applications y °C or °F scale available- jumper selectable y Heat Output configuration- Electric or Oil/Gas; y Fault input (24VAC) – red led indication C F jumper selectable COMPRESSOR DELAY y Energy saving – cost efficient, environmental friendly thermostat Wiring Diagram www.meitavtec.com | [email protected] 1-13 On-Off Thermostats TED-220-C1-3S Wall mount, 220VAC thermostat, with temperature display, suitable for Fan Coil applications (Cool only) The TED-220-C1-3S thermostat is suitable for commercial or residential applications to control a large variety of Fan Coil systems. ECONOMY This mechanical thermostat offers an output for Cool C as well as 3 fan speeds, making the TED-220-C1-3S the perfect solution for basic and simple climate EXT. SENSOR OPTION control in Cool Only configuration systems. Features y Wall mount, 220VAC thermostat y Output for Cool valve y External sensor – optional Wiring Diagram External sensor (option) T LO Fan Low (2.6) ME Fan Medium (2.6) HI Fan High (2.6) RE Compressor (0.5A) 0 Main Input 230VAC ~ 1-14 Friendly thermostat y Large, easy to read LCD display y 3 Fan speeds T y Energy saving – cost efficient, Environmental www.meitavtec.com | [email protected] y LCD display for ambient temperature and set point On-Off Thermostats TED-24-AUTO-SUPER Wall-mount, 24VAC thermostat, with 2 outputs for AC Heat and 1 output for Cool with 1 fan speed (24VAC) The TED-24-AUTO-SUPER thermostat suits commercial or COOL residential applications to control a large variety of HVAC systems. This mechanical thermostat offers 1 stage for Cool and 2 stages for Heat. Its easy to change configuration, using only jumpers, makes the TED-24-AUTO-SUPER the perfect solution for basic and easy climate control. Features y Wall mount, 24VAC thermostat y Heat Pump or Heat/Cool configuration available; jumper selectable y Heat Output configuration- Electric or Oil/Gas; jumper selectable y LCD display for ambient temperature and set point y External sensor – option AUTO CHANGE-OVER y °C or °F scale available- jumper selectable y Fan/Auto Fan EXT. SENSOR OPTION y Auto-Change-Over mode y Energy saving – cost efficient, environmental friendly thermostat Wiring Diagram www.meitavtec.com | [email protected] 1-15 On-Off Thermostats TES-220-HC11-3S Wall mount, 220VAC thermostat, for Air AC Conditioning & Fan Coil applications. The TES-220-HC11-3S thermostat suits commercial or residential applications and can control a large variety of HVAC systems, COOL including fan coils. HEAT This mechanical thermostat offers Cool and Heat outputs as well as 3 fan speeds, making the TES-220-HC11-3S the perfect solution for basic and simple climate control. ECONOMY C Features y Wall mount, 220VAC thermostat y Outputs for Cool & Heat y Energy saving – cost efficient, Environmental Friendly thermostat y Simple design and logic y 3 Fan speeds y External sensor – option Wiring Diagram External sensor (option) T T 3 Fan Low (2.6) 2 Fan Medium (2.6) HE H. Element (0.5A) 1 RE Fan High (2.6) Compressor (0.5A) 0 Main Input 230VAC ~ 1-16 www.meitavtec.com | [email protected] On-Off Thermostats - Programmable ETN-24-SUPER-3S-FP-PROG-EU-C 24VAC, wall-mount thermostat, with 5-1-1 days, AC Europe-type weekly program built-in, with Freeze Protection, for multiple HVAC configurations FC The ETN-24-Super-3S-FP-Prog-EU-C is an aesthetic, easy to use thermostat for commercial and residential applications. COOL It can control a large variety of HVAC systems with either Heat/Cool or Heat Pump configurations and offers numerous HEAT selectable or user adjustable features, such as Freeze Protection to protect system from freezing, Offset for temperature reading or an option for 3 minute compressor delay. AUTO CHANGE-OVER Its 5-1-1 program, with 4 x start time/ stop time per day is easy to use and can provide 24-hour comfort as well as energy savings. Overall, the ETN-24-Super-3S-FP-Prog-EU-C is an attractive, wall mount thermostat with a large, easy to read display. Features ECONOMY y Wall-mount, 24VAC thermostat y Energy saving thermostat y DIP switch selectable configurations: y Lock / Unlock thermostat buttons * Heat/Cool or Heat Pump system y Temp. scale - °C * Electric or Oil/Gas heat system y 3 minutes compressor delay – optional (DIP * Heat Pump in Cool or Heat y 5-1-1 programmable – 4 x start time / stop time per day y Modes: Cool, Heat, Auto Mode, Fan Only y 3 fan speed + Auto Speed y Set point limits- 10…30°C y Freeze protection – adjustable switch selectable) y Internal or external sensor – DIP switch selectable y External sensor- option PROG TIMER COMPRESSOR DELAY C EXT. SENSOR OPTION y IR remote control – option y Weekly Timer FREEZE PROTECT y Offset – for temp. reading adjustment - ±6°C LOCK OPT. Wiring diagram www.meitavtec.com | [email protected] 2-1 On-Off Thermostats - Programmable ETN-24-SUPER-PROG-EU Series 24VAC, wall-mount thermostat, AC with 5-1-1, Europe-type weekly program built-in and multiple Cooling and Heating stages The ETN-24-Super-Prog-EU is a stylish thermostat well suitable for commercial and residential applications. HEAT It can control a large variety of HVAC systems with either Heat/Cool or Heat Pump configurations and HP/HC offers a selectable number of heating and cooling stages. Its 5-1-1 program, with 2 x start time/ stop time per day is easy to use and can provide 24-hour comfort as ECONOMY well as energy savings. Overall, the ETN-24-Super-Prog-EU is an attractive, wall mount thermostat with a large, easy to read display. TIMER Features COMPRESSOR DELAY y Wall-mount, 24VAC thermostat y External sensor- option y DIP switch selectable configurations: y Lock – Unlock thermostat buttons * Heat/Cool or Heat Pump system y °C scale, 24hrs clock * Electric or Oil/Gas heat system y 3 minutes compressor delay – optional y 5-1-1 programmable – 2 x start time / stop time per day y Offset – for temperature reading adjustment LOCK OPT. y Internal or external sensor – DIP switch y 1 fan speed selectable y Emergency Heat selectable in Heat Pump mode y Set point limits- 10…30°C y IR remote control – option y Weekly Timer Models 2-2 EXT. SENSOR OPTION (DIP switch selectable) * Heat Pump in Cool or Heat Wiring diagram Cooling stages Heating stages ETN-24-HC11-PROG-EU 1 1 ETN-24-HC22-PROG-EU 2 2 ETN-24-HP21-PROG-EU 1 2 ETN-24-HP32-PROG-EU 2 3 Model C www.meitavtec.com | [email protected] On-Off Thermostats - Programmable ETN-24-SUPER-PROG-7DAYS-US Series 24VAC, Wall mount thermostat with 7-days, AC USA-type weekly program built-in and multiple Cooling and Heating stages The ETN-24-Super-Prog-7 Days-US is a stylish thermostat that is well suited for commercial and residential HEAT applications. It can control a large variety of HVAC systems with either HP/HC Heat/Cool or Heat Pump configurations and offers a selectable number of heating and cooling stages. Its 7-Day program, with 1 period (Set Cool/Set Heat) per day, is easy to use and can provide 24-hour comfort as well ECONOMY as energy savings. Overall, the ETN-24-Super-Prog-7 Days-US is an attractive, TIMER wall mount thermostat with a large and easy to read display. C Features y Wall-mount, 24VAC thermostat y Filter counter in hours- range: 0-900 (adjustable) y DIP switch selectable configurations: EXT. SENSOR OPTION y Offset for temp. reading adjustment - ±6°C * Heat/Cool or Heat Pump system RT03 y Set point limits for Cool & Heat (5…30°C) * Electric or Oil/Gas heat system y External sensor- option * Heat Pump in Cool or Heat y 7-day programmable – 1 period per day, each with Set y Lock – Unlock thermostat buttons y Voltage-free, normally-open fault input. Will Heat and Set Cool show signal on thermostat when active y Separate Cooling & Heating set points LOCK OPT. COMPRESSOR DELAY FAULT INPUT y 3 minutes compressor delay – optional (DIP y Emergency Heat available in Heat Pump mode switch selectable) y °C scale, 24 hr clock Wiring diagram Models Cooling stages Heating stages ETN-24-HC11-7DAYS-PROG-US 1 1 ETN-24-HC22-7DAYS-PROG-US 2 2 ETN-24-HP21-7DAYS-PROG-US 1 2 ETN-24-HP32-7DAYS-PROG-US 2 3 ALL-IN-ONE ALL-IN-ONE Model ETN-24-SUPER-7DAYS-PROG-US www.meitavtec.com | [email protected] 2-3 On-Off Thermostats - Programmable ETN-24-SUPER-PROG-US Series 24VAC, wall-mount thermostat AC with 5-1-1, USA-type weekly program built-in and multiple Cooling and Heating stages The ETN-24-Super-Prog-US is a stylish thermostat COOL well suitable for commercial and residential applications. HEAT It can control a large variety of HVAC systems with either Heat/Cool or Heat Pump configurations and HP/HC offers a selectable number of heating and cooling stages. Its 5-1-1 program, with 4 periods (Set Cool / Set Heat) per day, is easy to use and can provide 24- ECONOMY hour comfort as well as energy savings. Overall, the ETN-24-Super-US is an attractive, wall PROG mount thermostat with a large, easy to read display. C Features y Wall-mount, 24VAC thermostat y Set point limits- 5…30°C - adjustable y DIP switch selectable configurations: y External sensor- option * Heat/Cool or Heat Pump system y Lock – Unlock thermostat buttons * Electric or Oil/Gas heat system y IR remote control- option * Heat Pump in Cool or Heat y °C temperature scale y 5-1-1 programmable – 4 periods per day, each with Set Heat and Set Cool y Internal or external sensor – +/-6°C y 3 minutes compressor delay – DIP switch selectable y Double Set points (Cool & Heat) y Timer – AM/PM y Energy saving – cost efficient, environmental friendly thermostat Models 2-4 Wiring Cooling stages Heating stages ETN-24-HC11-PROG-US 1 1 ETN-24-HC22-PROG-US 2 2 ETN-24-HP21-PROG-US 1 2 ETN-24-HP32-PROG-US 2 3 ALL-INONE ALL-INONE ETN-24-SUPER-PROG-US EXT. SENSOR OPTION TIMER DIP switch selectable y Offset for temperature reading adjustment - Model LOCK OPT. www.meitavtec.com | [email protected] diagram RT04 On-Off Thermostats - Programmable FMT-24-SUPER-PROG Flush-mount, 24VAC thermostat, 5-1-1 AC programmable, with various selectable A/C configurations The FMT-24-SUPER-PROG is a stylish thermostat suitable for commercial and residential applications. It can control a HEAT large variety of HVAC systems with either Heat/Cool or Heat Pump configurations and offers a selectable number of heating and cooling stages. Its 5-1-1 program, with 4 periods (Set Cool/Set Heat) per day, is easy to use and can provide 24-hour comfort as well as energy savings. Overall, the FMT-24-SUPER-PROG is an attractive thermostat with a large and easy to read display. Features TIMER y Flush-mount, 24VAC thermostat y Energy saving – cost efficient, Environmental Friendly thermostat y DIP switch selectable configurations: * Heat/Cool or Heat Pump system y Offset – for temperature reading adjustment * Electric or Oil/Gas heat system y 2 set points (Cool & Heat) * Heat Pump in Cool or Heat y Set point limits- password protected y 5-1-1 programmable; 4 periods per day, each with y External sensor- option Set Heat and Set Cool. y Lock – Unlock buttons function y Auto Change-Over mode option y IR remote control- option y AM/PM clock Wiring diagram Models Cooling Stages Heating Stages Fan Speeds FMT-24-HC11-PROG 1 1 1 FMT-24-HC22-PROG 2 2 1 FMT-24-HP21-PROG 1 2 1 FMT-24-HP32-PROG 2 3 1 ALL-IN-ONE ALL-IN-ONE 1 Model FMT-24-SUPER-PROG www.meitavtec.com | [email protected] 2-5 On-Off Thermostats - Programmable ETN24-HC21-PROG-ECO Wall-mount, 24VAC thermostat, with weekly AC program built-in and fresh air damper output The ETN-24-HC21-PROG-ECO is a fully featured, stylish thermostat, suitable for commercial and residential applications. It can control a large variety of COOL HVAC systems with different configurations. It offers a selectable number of heating and cooling stages and a HEAT fresh Air Damper output - damper opens automatically F or manually. The ETN-24-HC21-PROG-ECO is an attractive thermostat with a large, easy to read display. ECONOMY Features y 24VAC wall-mount thermostat y 2 stages of Heat and 1 stage of Cool y Adjustable Electric and Oil/Gas system y Outdoor sensor- option y Fresh Air Damper output y 5-1-1 programmable; 4 periods per day, each with Set Heat and Set Cool Wiring diagram 2-6 www.meitavtec.com | [email protected] y Energy saving – cost efficient, RT03 Environmental Friendly logic COMPRESSOR DELAY y Offset – for temperature reading adjustment y Freeze Protection even when thermostat is OFF y Economy mode (set back) y °F scale, AM/PM clock EXT. SENSOR OPTION FREEZE PROTECT On-Off Thermostats - Programmable ETN24-HC21-PROG-OA 24VAC, wall-mount thermostat, with 5-1-1 USA- AC type weekly program built-in and fresh air damper output. DAMPER CONTROL The ETN-24-SUPER-PROG-OA is a fully featured, stylish thermostat suitable for industrial, commercial and residential applications. HEAT It can control a large variety of HVAC systems with different configurations; Cool, Heat (Electric or Gas) AUTO FAN systems. It also offers selectable number of heating and cooling stages and Fresh Air Damper output. ECONOMY F The ETN-24-SUPER-PROG-OA is an attractive, with a large, easy to read display. RT03 Features y 24VAC, wall -mount thermostat y 2 stages of Heat and 1 stage of Cool y Electric or oil/gas system- selectable y External sensor- option y Fresh Air Damper output – 24VAC * Controlled by time ONLY (select number of minutes per ½ hour- min.= 0 min (FAD never y Energy saving – cost efficient, environmental friendly PROG thermostat y 5-1-1 programmable; 4 periods per day, each with Set Heat and Set Cool EXT. SENSOR OPTION y IR remote control- option (programmable) y Offset – for temperature reading adjustment y °F scale, AM/PM clock opens), max.= 30 min (FAD is always open) * FAD will NOT work between 7 PM and 7 AM Wiring diagram www.meitavtec.com | [email protected] 2-7 On-Off Thermostats - Programmable ETN24-HC21-PROG-TS 24VAC, wall-mount thermostat, with 5-1-1 USA- AC type weekly program built-in and special damper control in Heat mode. DAMPER CONTROL The ETN-24-SUPER-PROG-TS is a fully featured and stylish thermostat, especially designed for two-story residential applications. Thermostat on first floor, remote sensor on second HEAT floor and motorized damper in duct system. In heat mode, damper closes when temperature on second floor is 2 degrees (adjustable) higher than on first floor. AUTO FAN This diverts all air to first floor and balances temperature throughout the house. COMPRESSOR DELAY Features y Wall-mount, 24VAC thermostat y 2 stages of Heat and 1 stage of Cool y Electric or oil/gas system- selectable y Remote 2nd floor temperature sensor y Power open/Spring close damper output- 24VAC (works only in Heat mode y °F scale, AM/PM clock ECONOMY y Energy saving – cost efficient, y 5-1-1 programmable; 4 periods per day, 2-8 www.meitavtec.com | [email protected] RT03 each with Set Heat and Set Cool y IR remote control - option PROG (programmable) y Backlight display on LCD y Offset – for temperature reading adjustment Wiring diagram F environmental friendly thermostat TIMER EXT. SENSOR OPTION On-Off Thermostats - Programmable CTR-24-SUPER Wall mount, 24VAC thermostat, programmable, with AC an extra connection for an IR for a remote control from a second location The CTR-24-SUPER thermostat offers a selectable number of heating and cooling stages for Heat Pump or Heat/Cool systems. The CTR-24-SUPER enables connection of an extra IR receiver ECONOMY panel for remote control from a second location. In addition, it offers an alarm output, a fault input and also indicates outdoor temperature. With built-in weekly programming (where set Cool, set Heat AUTO CHANGE-OVER may be programmed), the CTR-24-SUPER is a convenient, temperature control solution. HP/HC Features y Main supply- 24VAC y Energy saving – cost efficient, environmental RT03 friendly thermostat y DIP switch selectable configurations: y Multiple stages for Cooling and Heating – * Heat/Cool or Heat Pump system ALARM up to 3 cooling stages and 3 Heating stages * Electric or Oil/Gas heat system y Alarm * Heat Pump in Cool or Heat output – 24VAC dry contact, TIMER normally-open * Temperature scale- °C or °F y Fault Input– 24VAC y 5-1-1programmable; 4 periods per day, each with Set FAULT INPUT y External temperature sensor- option Heat and Set Cool y Outdoor temperature sensor- option y Limit Cool and Heat set-point y Extra IR receiver panel for remote control PROG EXT. SENSOR OPTION Wiring diagram Y1 Fault in (24VAC) Y2 B/O HU W2 W1 W3 G1 FD G2 AL AL RC AUX RH T1 C T1 14 T0 15 T0 16 Main input 24VAC Return air sensor Outdoor temp. sensor External IR receiver (option) www.meitavtec.com | [email protected] 2-9 On-Off Thermostats - Programmable BDIR-24-SUPER-PROG Wall-mount, 24VAC thermostat, AC with 5-1-1 USA-type Weekly Program built-in, operable via Remote Control only. The BDIR-24-Super is a stylish thermostat, ideally suitable for commercial applications, as it is operable via IR remote control only. It can control a large variety of HVAC systems with either Heat/Cool or Heat Pump configurations and HEAT offers a selectable number of heating and cooling stages. Its 5-1-1 program, with 4 periods (Set Cool/Set Heat) per day, is easy to use and can provide 24-hour comfort as well as energy savings. ECONOMY Overall, the BDIR-24-SUPER-PROG is an attractive, wall mount thermostat with a large, easy to read display. PROG Features y Wall-mount, 24VAC thermostat y 5-1-1 programmable; 4 periods per day, each with Set Heat and Set Cool y DIP switch selectable configurations: * Heat/Cool or Heat Pump system y Operable via IR Remote Control only * Electric or Oil/Gas heat system y 2 set points (Cool & Heat)- * Heat Pump in Cool or Heat for auto-change-over * °F or °C temperature scales y External sensor- option y Energy saving – cost efficient, environmental friendly thermostat Wiring diagram Models Cooling Stages Heating Stages Speeds BDIR-24-HC11-1S 1 1 1 BDIR-24-HC22-1S 2 2 1 BDIR-24-HP21-1S 1 2 1 2 3 1 ALL-INONE ALL-INONE 1 Model BDIR-24-HP32-1S BDIR-24-SUPER 2-10 www.meitavtec.com | [email protected] EXT. SENSOR OPTION RT04 On-Off Thermostats - Programmable - Voice & Phone CEO-24-HC22 “Talking Thermostat” with telephone & voice AC capabilities, “call-out” options and 5-1-1 weekly programmable. Perfect for controlling temperature in second home COOL The CEO-24-HC22 thermostat brings you the state of the art technology in capabilities. It thermostat is the with perfect telephone choice for and voice controlling temperature in your second home, cabin, condo or office from a remote location. Want to Heat up or Cool down your vacation home before you arrive while you are on the way? Forgot to change mode and left home? Call your CEO-24-HC22 thermostat and receive verbal information on actual temperature and thermostat settings to change them. Not only that but, the CEO-24-HC22 will call you in case of an alarm situation to enable you change set point, mode or turn the system off. This unique thermostat offers also 5-1-1 weekly programming, so together with its built-in communication, alarm activation in case of reaching Cool /Heat limits and further remarkable qualities, the CEO-24-HC22 is the ultimate RT03 thermostat to give you peace of mind! ALARM Features y Main supply- 24VAC y Telephone communication: * thermostat calls-out to user in case of alarm situation * up to 3 numbers can be programmed to be called in case of alarm * thermostat re-dials every 2 minutes in case of busy signal * call thermostat from remote location to check or set mode and temperature y Modes: Cool /Heat / Auto-Change-Over/ Auto-fan / Fan-On y Economy mode – to be activated when you leave home for any period of time y Up to 2 stages of Heat and 2 stages of Cool y Heat output- Electric or Oil/Gas jumper selectable y Selectable system configuration- AUTO CHANGE-OVER ECONOMY Heat Pump / Millivolt (dry contact) y Internal / External sensor- jumper selectable y 4 minutes compressor delay – jumper selectable y Clock mode – 24 hours / 12 hours (AM/PM) – TIMER FAULT INPUT jumper selectable y General purpose output (e.g. boiler) – to be activated also by telephone for unlimited time y External sensor- option y °C or °F Temperature display y Real Time Clock PROG EXT. SENSOR OPTION y 5-1-1 weekly program Wiring diagram www.meitavtec.com | [email protected] 2-11 On-Off Thermostats - Programmable - Voice & Phone CEM-24-SUPER “Talking Thermostat” with telephone and voice options, and 5-1-1 weekly programmable, perfect for controlling temperature in second home The CEM-24-SUPER thermostat brings you the state of the COOL art technology in thermostat with telephone and voice capabilities. It is the perfect choice for controlling temperature in your second home, cabin, condo or office from a remote location. Want to Heat up or Cool down your vacation home before you arrive while you are on the way? Forgot to change AUTO FAN mode and left home? Call your CEM-24-SUPER thermostat and receive verbal information on actual temperature and thermostat settings and command to raise or lower temperature, change mode or turn the system on or off. HP/HC This unique thermostat offers also 5-1-1 weekly programming, so together with its built-in telephone capability, alarm activation in case of reaching Cool /Heat limits and further remarkable qualities, the FAULT INPUT CEM-24-SUPER is the ultimate thermostat to give you peace of mind! Features y Main supply- 24VAC y Selectable system configuration- y Telephone communication – Call thermostat and listen to information on temperature settings, or set mode and temperature from a remote location through telephone y Alarm activated when temperature reaches preset high or low limit, or when fault input is active – indicated by red LED y Modes: Cool /Heat /Auto-Change-Over /Auto-fan /Fan-On y Economy mode – to be activated when you leave home for any period of time www.meitavtec.com | [email protected] Fan Compressor 1 Heat element 2 Compressor 2 Wiring diagram 2-12 y Up to 2 stages of Heat & 2 stages of Cool y Heat output- Electric or Oil/Gas - jumper selectable y Heat Pump in Cool /Heat – jumper selectable y Internal / External sensor- jumper selectable y 5-1-1 weekly program ALARM Heat-Cool / Heat Pump / Millivolt (dry contact) y General purpose output (e.g. boiler) – to be activated also by telephone for a un/limited time y Large, easy to read display PROG EXT. SENSOR OPTION On-Off Thermostats - Programmable - Voice & Phone CEV-24-SUPER Wall-mount, 24VAC thermostat loudspeaker, especially with designed for built in AC visually- impaired individuals. COOL The CEV-24-SUPER brings the latest technology in room temperature control and is perfectly suitable for residential and commercial applications. With voice option and built-in speakers, the CEV-24-SUPER is ideal for visually impaired individuals. Pressing the AUTO FAN command buttons activates the voice, which guides the user to change mode, set point, etc. Available in C° or F° scale. ECONOMY C With the CEV-24-SUPER, climate control becomes accessible F to everyone in a simple, user-friendly way. Features y Main supply- 24VAC y Up to 2 stages of Heat and 2 stages of Cool y Built-in speakers and voice option- thermostat speaks to y Selectable Heat output- Electric or Oil/Gas user allowing him to: TIMER (jumper selectable) * Turn On/Off thermostat y Celsius or Fahrenheit temperature scale * Verify & change mode HP/HC PROG External sensor- option * Verify & change set point EXT. SENSOR OPTION y Outdoor sensor- option * Verify indoor & outdoor temp. y Alarm indication output * Verify time of day y Fault input, 24VAC y Ideal for visually-impaired individuals y 5-1-1 weekly program y Heat/Cool or Heat Pump - selectable y Energy Saving – cost efficient, Environmental Friendly y Economy mode (set-back/unoccupied mode) logic built-in Wiring diagram Models Model Cool Heat Speeds CEV-24-HC11 1 1 1 Heat element 1 / Heat pump W1 CEV-24-HC22 2 2 1 Fan G1 Compressor 1 Y1 Heat element 2 W2 Compressor 2 Y2 CEV-24-HC21 CEV-24-SUPER (all in oneHC11, HC22, HC21) 1 2 1 1 or 2 1 or 2 1 AL Alarm indication AL AX Fault input from system RC Return air sensor 0 RH Q2 T1 C Main input 24VAC www.meitavtec.com | [email protected] 2-13 2-14 www.meitavtec.com | [email protected] Proportional Thermostats 0-10V ETN-24-P/PD-FC-SUPER2 Wall mount, 24VAC thermostat, for all Fan Coil FC Proportional valve applications. The ETN-24-P/PD-FC-SUPER2 is a fully featured, advanced thermostat suitable for light commercial, residential or apartment systems to control a wide array COOL of Fan Coil applications. This superior thermostat offers various configurations HEAT according to customer's requirements, applicable by DIP 1/2/3 switches. It suggests 2 separate proportional outputs for SPEEDS Cool & Heat for 4-pipe Fan Coil systems, or a single proportional output for both Cool & Heat for 2-pipe AUTO FAN systems. In addition, it has an option for 1, 2 or 3 fan EXT. SENSOR OPTION speeds as well as an option for an Auto-change-over and an external sensor. Suitable for Wholesalers to keep a AUTO CHANGE-OVER stock on the shelf and supply the proper configuration according to customer's specifications. ECONOMY All these qualities make the ETN-24-P/PD-FC-SUPER2 C a superior, flexible solution for easy temperature control. Features F Wiring diagram RT03 y Wall mount , 24VAC thermostat y 1 or 2 proportional (0-10V or 2-10) output for Cool & Heat – DIP switch selectable y 1,2 or 3 fan speeds – DIP switch selectable y Auto-change-over mode by T2 water sensor y Auto Fan Speed y External sensor – optional y Energy saving – cost efficient, environmental friendly thermostat y Celsius or Fahrenheit temperature scales – DIP switch selectable y Daily, digital Timer – optimal when you are asleep or away y Set point limits y Temp Reading Offset – -5°..0..+5° y Silicon rubber buttons y IR option www.meitavtec.com | [email protected] 3-1 Proportional Thermostats 0-10V ETN24-PH-FC-SUPER Wall-mount, 24VAC thermostat, with proportional output for Cool (0-10VDC), onoff output for Heat. Suitable for Cool/Heat or Cool Only applications The ETN24-PH-FC-SUPER is an advanced, energy COOL saving thermostat suitable for light commercial, residential or apartment systems to control HEAT Cool/Heat or Cool Only, Fan Coil applications. This thermostat offers various configurations, either Cool/Heat/Auto, Cool/Heat/Fan, or alternatively Cool Only, all of which are selectable with 1, 2 or 3 fan speed control. For Cool/Heat applications, it allows proportional output (0-10VDC) for Cool and On/Off output for Heat, while for Cool Only, it enables only ECONOMY 1 proportional output for Cool. In addition, it offers Economy mode for maximum energy saving. All these qualities make the ETN24-PH-FC-SUPER suitable for wholesalers, keeping a stock on the shelf and supplying the proper configuration according to customer's specifications. Features y Fan Only y 1 proportional output for Cool (0-10VDC) and y Lock buttons - option 1 on-off output for Heat y y Modes: Cool/Heat/Auto, Cool/Heat/Fan, Cool Only Energy saving – cost efficient, environmental friendly thermostat y 1, 2 or 3 fan speeds + Auto speed y Celsius or Fahrenheit temperature scales y Economy mode y IR option y Window contact, normally open / normally closed – y Set point limits - 10°..30° C (50..86°F) DIP switch selectable +set points for Economy mode y Internal / external sensor – DIP switch selectable y Temp. offset – +5°C y Auto-fan Models Electric Oil / Gas 3-2 C F LOCK OPT. y Wall mount, 24VAC thermostat Heater AUTO CHANGE-OVER Wiring diagram Mode Fan Speed Cool, Fan Only 1/2/3 Cool, Heat, Fan Only 1/2/3 Cool, Heat, Auto, Fan Only 1/2/3 Cool, Fan Only 1/2/3 Cool, Heat, Fan Only 1/2/3 Cool, Heat, Auto, Fan Only 1/2/3 www.meitavtec.com | [email protected] EXT. SENSOR OPTION Proportional Thermostats 0-10V FMH-24-P-1S Flush-mount 24VAC Thermostat, with 2 separate FC proportional outputs for Cool & Heat (0-10VDC) and 1 fan speed. COOL The FMH-24-P-1S is a fully featured thermostat suitable for light commercial, residential or apartment applications. It HEAT has 2 proportional outputs for Cool and Heat (0-10VDC) and 1 fan speed. It is a smart looking, flush mount thermostat, with a soft aesthetic shape and a large, easy to read LCD display. Features y Flush-mount, 24VAC thermostat y Modes: Cool / Heat / Auto / Fan y 2 separate proportional outputs for Cool and Heat y Temperatures Limit – optional (0-10V or 2-10V) y 12-h Timer (using Remote Control) y 1 fan speed TIMER C y Silicon rubber key pads y Hand held remote control – optional y Temperature reading offset – optional ± 6° RT03 y Large, easy to read display y Simple & friendly setting y Energy saving – cost efficient, environmental friendly thermostat Wiring diagram Y 0 W 0 Proportional output for cool (0-10VDC) Proportional output for heat (0-10VDC) R Main Input 24VAC C G Fan (0.5A) www.meitavtec.com | [email protected] 3-3 Proportional Thermostats 0-10V FMH-24-PD-1S Flush-mount, 24VAC thermostat, with a single proportional output for both Cool and Heat 0-10V and 1 fan speed. OUTPUT The FMH-24-PD-1S is a fully featured, easy to operate thermostat suitable for light commercial and residential applications. It offers 1 proportional HEAT output for both Cool and Heat (0-10VDC or 210VDC) and 1 fan speed. It is an attractive, flush mount thermostat, with a large and easy to read display. Features y Modes: Cool / Heat / Fan y 1 proportional output for both Cool and Heat y Large & easy to read display y 0-10VDC or 2-10VDC proportional output y Silicon rubber key pads y 1 fan speed y Simple & friendly setting Wiring diagram 3-4 C y Flush-mount, 24VAC thermostat www.meitavtec.com | [email protected] Proportional Thermostats 0-10V FMT-24-PD-3S FC Flush-mount, 24VAC thermostat, with a single proportional output for both Cool & Heat and 3 fan speeds. The FMT-24-PD-3S is a fully featured, stylish thermostat suitable for light commercial, residential or apartment, COOL 2-pipe fan coil applications. It offers 1 proportional output for both Cool and Heat (0-10VDC or 2-10VDC) HEAT and 3 fan speeds. The FMT-24-PD-3S is a smart looking, flush mount thermostat, with a soft aesthetic shape and a large, ECONOMY easy to read LCD. EXT. SENSOR OPTION Features y Flush-mount, 24VAC thermostat y Modes: Cool /Heat /Fan Only y 1 proportional output for both Cool and Heat y Large & easy to read display y 3 fan speeds + auto speed y Silicon rubber key pads y External sensor – optional y Simple & friendly setting Wiring diagram External sensor (option) T To R Main Input 24VAC C HI High ME Medium LO Low Fan (0.5A) Y Proportional output for cool and heat 0-10VDC 0 W Not in use www.meitavtec.com | [email protected] 3-5 Proportional Thermostats 0-10V ETN-24-P-1S (Cool Only) Wall-mount thermostat for VAV applications, with 1 proportional output (0÷10VDC) for Cool only FC The ETN-24-P-1S (Cool Only) thermostat is a fully 0-10V featured and stylish thermostat suitable for light OUTPUT commercial, residential or apartment applications. This thermostat has proportional output for Cool (010VDC or 2-10 VDC), large, easy to read display and a hand held remote control. Features y Wall mount, 24VAC thermostat y 1 proportional output for Cool (0-10V or 2-10V) y External Temperature Sensor - Option y Differential - Adjustable for 0–10 VDC y Offset temperature reading - Adjustable y Energy saving – cost efficient, environmental friendly logic Wiring diagram 0 Proportional output for cool (0-10VDC) Y T External sensor To G Fan (24VAC, 0.5A) C Main Input 24VAC R 3-6 www.meitavtec.com | [email protected] y Temperature limit range (10°C…30°C, 50°F…86°F) y Two different scales: Fahrenheit or Celsius ECONOMY C F EXT. SENSOR OPTION y Lock buttons option y Hand Held Remote Control – Option LOCK OPT. Proportional Thermostats 0-10V TED-24-P-3S (FAN 230 VAC) Wall-mount, 24VAC thermostat, with 2 proportional FC outputs for Cool and Heat (0-10V) and 3 fan speeds (230VAC). The TED-24-P-3S is an attractive, fully featured thermostat suitable for light commercial, residential or apartment COOL applications. It has two proportional outputs for Cool and Heat and 3 fan speeds. HEAT All these qualities make the TED-24-P-3S the perfect solution for basic and easy climate control. Features ECONOMY y Wall-mount, 24 VAC Thermostat C y 2 proportional outputs (0-10 VDC) for Cool & Heat y 3 fan speeds - 230 VAC outputs (using 220V feed) y External sensor – option y Energy saving – cost efficient, environmental friendly thermostat y Simple & friendly setting Wiring diagram External sensor (option) T T Y Cool valve 0-10VDC W Heat valve 0-10VDC R Main Input 24VAC C R C 230VAC Input (common for fan) ~ HI Fan high ME Fan medium LO Fan low Fan (0.5A) www.meitavtec.com | [email protected] 3-7 Proportional Thermostats 0-10V TED-24-P-3S-Cool Only (FAN 230 VAC) Wall-mount, 24VAC thermostat, with 1 proportional output for Cool only (0-10V) and 3 fan speeds (230VAC) The TED-24-P-3S-Cool Only is a fully featured, easy to operate thermostat suitable for light commercial, COOL residential or apartment applications. It has one proportional output for Cool Only and 3 fan speed outputs, 230 VAC. It is an attractive, wall mount thermostat, with a ECONOMY large easy to read display. C Features y Wall-mount, 24VAC thermostat y Simple & friendly setting y 1 proportional output (0-10 VDC) for Cool y Large, clear LCD display y 3 fan speeds y Energy saving – cost efficient, environmental friendly thermostat y Fan - 230 VAC power supply y External sensor - optional Wiring diagram External sensor (option) T T Y Cool valve 0-10VDC W R Main Input 24VAC C 230VAC Input (common for fan) ~ 3-8 HI Fan high ME Fan medium LO Fan low Fan (0.5A) www.meitavtec.com | [email protected] R C EXT. SENSOR OPTION Proportional Thermostats - 3 wires ETN-24-PM2 series Wall-mount, 24VAC thermostat with 2 separate AC proportional outputs for Cool & Heat (3-wire) and 1 or 3-fan speeds COOL The ETN-24-PM2 Series is suitable for light commercial or residential applications. It offers 2 proportional outputs (3-wire) for Cool & Heat valves and 1 speed or 3 speeds, 1/3 24VAC fan. SPEEDS The ETN-24-PM2 is an attractive thermostat with a large, easy to read, display. 3-WIRE OUTPUT Features y Wall mount, 24VAC thermostat y Auto speed y 2 Proportional and Integral outputs (3-wire) y Offset - ±6°C for Cool & Heat y Set point temp. – 10…30°C y Adjustable Open/Close time for motor (10 to 400 seconds) y Auto-fan y Energy saving – cost efficient, environmental y Modes - Cool / Heat / Auto friendly thermostat y External / Internal sensor – DIP switch selectable Models Model Fan Speeds ETN-24-PM2-1S 1 ETN-24-PM2-3S 3 Wiring diagram www.meitavtec.com | [email protected] 3-9 Proportional Thermostats - 3 wires ETN-24-PMH series Wall mount, 24 VAC thermostat, for 2-pipe FC systems, with 1 proportional output (3-wire, 24VAC) for Cool and an on/off output for Heat The ETN-24-PMH Series is well suited for commercial or residential applications. HEAT It offers 1 proportional output (3-wire, 24VAC) for Cool and an on/off output for Heat. It is suitable for 2-pipe systems only and has 1 fan speed or 3 fan speeds, 24 VAC. The ETN-24-PMH is an attractive thermostat, with a 3-WIRE OUTPUT large, easy to read display. Features y Wall mount – 24VAC thermostat y Fan delay after Electric heater operation y Adjustable Open/Close time for motor (10 to 250 y Energy saving – cost efficient, environmental friendly thermostat IR seconds) y 1 Proportional and Integral output (24VAC) , y Auto speed (only in 3 speed model) 3 wire, for Cool y HEAT output (on/off relay) - 24 VAC y 1 or 3 fan speed control Models Model Fan Speeds ETN-24-PMH-1S 1 ETN-24-PMH-3S 3 Wiring diagram 3-10 remote control option www.meitavtec.com | [email protected] y Auto fan - selectable Proportional Thermostats - 3 wires ETN-24-P/PM-1S (Cool Only) Wall mount, 24VAC thermostat, with 0-10VDC VAV output for Cool and 3-wire output for damper control 0-10V OUTPUT The ETN-24-P/PM-1S (Cool Only) thermostat is a fully featured and stylish thermostat suitable for light commercial, residential or apartment applications. ECONOMY It offers a proportional output for Cool (0-10VDC) as well as another 3-wire proportional output, ideal for dampers. C The ETN-24-P/PM-1S (Cool Only) is an attractive, stylish F thermostat with a large, easy to read display and an 3-WIRE OUTPUT optional IR remote control. Features y Wall mount, 24VAC thermostat y Lock buttons y 0÷10V or 2÷10V Cool Output y Two Temp. scales: Fahrenheit or Celsius y 3 Wire, proportional output– Open / Close, time adjustable y External Sensor - Option y Differential - adjustable for 0÷10 VDC y Offset for temperature reading adjustment y Display for set temperature only – selectable by DIP switch y Hand Held Remote Control – Option RT03 position y Energy saving – cost efficient, Environmental Friendly algorithm Wiring diagram www.meitavtec.com | [email protected] 3-11 3-12 www.meitavtec.com | [email protected] Humidity Controllers CHU-24-SUPER Wall-mount, 24 VAC thermostat, for controlling AC Temperature & Humidity, weekly programmable The CHU-24-SUPER thermostat is a combined Temperature & Humidity controller. HEAT It offers a selectable number of heating and cooling stages as well as an output for humidifier or de-humidifier. The HUMIDITY CHU-24-SUPER has a built-in humidity sensor, which allows adjustment of a Humidity Set Point. It also offers weekly programming (where set Cool, set Heat HP/HC and set Humidity may be programmed) and alarm indication in case temperature or humidity limits are exceeded. ECONOMY ALARM Features y Main supply- 24VAC y System configuration- Heat Pump or Heat/Cool (jumper selectable) y Multiple stages for Cooling & Heating y Output for Humidifier or De-Humidifier (jumper selectable)- 24VAC y Humidity sensor built-in (0-10VDC) y Adjustable Heat configuration; Electric or Oil/Gas system (jumper selectable) y Energy saving – cost efficient, PROG environmental friendly thermostat y 5-1-1 weekly program with programmable set Cool, set Heat and Set Humidity y Re-heat function in humidity logic y Alarm output (24VAC) ̶ Indication in case temperature or humidity limits are exceeded y Adjustable temperature set point range ̶ 5°C - 35°C y Adjustable humidity set point range ̶ 20%-70% RH Wiring diagram www.meitavtec.com | [email protected] 4-1 Humidity Controllers ERHU-55 Wall-mount, 12VDC Humidity Controller for de-humidification only. HUMIDITY The ERHU-55 is a Humidity controller with a built-in humidity sensor and an output for de-humidification via a compressor. The ERHU-55 allows users to adjust Humidity Set Point and the desired fan speed. The main input and outputs are 12VDC, and therefore the ERHU-55 must be used with power supply PS102. Features y Main supply – 12VDC y Adjustable humidity set point y On/Off output for De-Humidification (via compressor) y 3 Fan speeds- manually y Humidity sensor built-in Wiring diagram 4-2 www.meitavtec.com | [email protected] adjustable Humidity Controllers DEH-2000 Wall-mount, 24VAC, humidity ONLY controller with Fresh Air Damper output and weekly program built-in. ECONOMY The DEH-2000 has a built-in humidity sensor, which allows adjustment of a HUMIDITY SET POINT. It offers a DAMPER CONTROL humidifier and de-humidifier output (24VAC) as well as a weekly program for the operation of Fresh Air Damper. COMPRESSOR DELAY PROG Features y Main supply- 24VAC y On/Off output for Humidifier- 24VAC y On/Off output for De-Humidifier- 24VAC y Output for Fresh Air Damper y Humidity sensor built-in y Display of T-ambient in °C or °F y 5-1-1 weekly program (4 x start/stop) for Fresh Air Damper operation y Fan always runs when ventilation occurs (FAD open), even if Fan has been set to “Off” y Re-heat function in humidity logic y Adjustable humidity set point range- 20%-90% y Energy saving – cost efficient, environmental friendly thermostat Wiring diagram www.meitavtec.com | [email protected] 4-3 Humidity Controllers ETN-24-P-3S-HU Wall-mount, 24VAC, temperature and humidity AC controller (de-humidification only), with proportional integral outputs for Cool and Heat It offers 2 separate Proportional Integral (0-10VDC) outputs and 3 Fan Speeds; one output for Cool & HEAT De-Humidification and another for Heat. With inputs for external temperature and humidity sensors, the ETN-24-P-3S-HU allows the user to adjust both Temperature and Humidity set points. C Features y Wall mount, 24VAC thermostat y Energy saving – cost efficient, y 2 separate Proportional Integral (0-10VDC) environmental friendly thermostat y Input for external humidity sensor outputs: * Cool and Dehumidification (0-10VDC) * Heat y Humidity set point range- 40%-70% RH y 2 adjustable set points; temperature and humidity y Works with Meitav-tec’s GHU sensor- y Auto-Changeover mode combined temperature & humidity sensor y Input for external temperature sensor for room or duct y Re-heat function in humidity logic (only in Auto-Changeover mode) Wiring diagram 0 W 0 Y T To Proportional output for Heat (0-10V) Proportional output for Cool (0-10V) External sensor (option) HU Humidity sensor 0 G3 High G2 Medium G1 Low Fan (0.5A) C Main Input 24VAC R 4-4 www.meitavtec.com | [email protected] EXT. SENSOR OPTION Humidity Controllers M5003-24VAC/12VDC AC Wall mount, 24VAC or 12VDC controller for Temperature & Humidity The M5003 thermostat is a combined Temperature & Humidity controller, available in either 24VAC or 12VDC. HEAT The M5003 offers a selectable number of heating and cooling stages as well as 2 outputs for Humidifier and DeHumidifier. The M5003 allows adjustment of Humidity & DeHumidity set points and also offers weekly programming. COMPRESSOR DELAY Features y Main supply- 24VAC or 12VDC y Multiple stages for Cooling and Heating (up to 2 stages of Heat and 2 stages of Cool) y Energy saving – cost efficient, environmental friendly controller ECONOMY C y Adjustable Heat configuration; Electric or Oil/Gas system (jumper selectable) y Output for Humidifier PROG y Output for De-humidifier y 2 separate set points for humidification and dehumidification y Input for external temperature sensor y Input for external humidity sensor (0-10VDC) y 5-1-1 weekly program with programmable temperature set point, humidity set point and de-humidity set point y Re-heat function in humidity logic y Works with Meitav-tec’s GHU sensor- combined temperature and humidity sensor for room or M5003-24VAC 24VAC Fan (0.5A) 12VDC Humidifier (0.5A) M5003-12VDC Heat element 2 (0.5A) Voltage Heat element 1 (0.5A) Model Compressor 1 (0.5A) (Cool / De-hum) Models Compressor 2 (0.5A) duct Wiring diagram www.meitavtec.com | [email protected] 4-5 Humidity Controllers M5001-24-4X0-10VDC Wall mount, 24VAC controller for Temperature & Humidity The M5001-24-4X0-10VDC controller is a multi- HEAT purpose display controller. It offers unique flexibility 0-10V and simplicity, allowing users proportional control of OUTPUT both temperature and humidity. The M5001-24-4X0-10VDC offers 4 different ECONOMY proportional outputs; Cool, Heat, Humidifier and De- C humidifier. Additional features such as wide temperature and humidity ranges, adjustable differentials and adjustable dead-zones, make the M5001-24-4X0-10VDC a truly unique and practical controller. Features y Wall mount, 24VAC controller y Range temperature from 0°C-60°C y Range humidity from 10%-99% RH y Separate Proportional Cool & Heat outputs (0-10VDC or 2-10VDC) y Adjustable humidity differential (0.5%3.0% RH) and dead-zone (0.5%-5.0% RH) y Automatic operation y Works with Meitav-tec’s GHU sensorcombined temperature and humidity sensor for room or duct y Separate Proportional Humidifier and DeHumidifier outputs (0-10VDC or 2-10VDC) y Adjustable temperature differential (0.5°C1.5°C) and dead-zone (0.5°C-2.5°C) Wiring diagram 4-6 www.meitavtec.com | [email protected] Fan Coil Stand Alone Controllers FMH-FC-SUPER3 Flush-Mount, 230VAC or 110VAC Thermostat for all FC Fan Coil applications, with special input. The FMH-FC-SUPER3 series allows users the flexibility of COOL having one main controller for most Fan Coil applications. It can be flush-mounted or installed directly into the Fan HEAT Coil, with an external sensor for the return air. The FMH-FC-SUPER3 also offers a special input for 1 of 4 options: 1- Auto-change over sensor, where the incoming water temperature dictates the Mode. 2- Contact input for a remote switch, which changes the Mode of one or many thermostats linked together. 3- Contact input for a remote switch, which activates Economy mode. 4- Contact input to Turn OFF units. Features y Flush-Mount, 230VAC or 110VAC, Thermostat y Can be connected to: * 4 pipe system – 2 valves * 2 pipe system – 1 valve * Fan Coil – no valve y DIP switch control options: * Manual Cool/Heat or Auto-Change * Display for set temperatures only y Special Input for: * Auto-change over sensor - mode is set based on temperature of the incoming water flow, ideal for 2-pipe systems. sets the mode of one or more thermostats linked together (available only for 2-pipe systems). * Contact input to activate Economy Mode * Fan/Auto Fan or all time Auto Fan – selectable - unit reverts to pre-determined economy * Internal / External sensor set points y Lock buttons – password protected y Set point limits – password protected y Unit ‘On’ ‘Off’ Timer’ C * Contact input for a remote switch, which * Contact input to turn the unit Off y Energy saving – cost efficient, environmental friendly thermostat y Available in different colors www.meitavtec.com | [email protected] 5-1 Fan Coil Stand Alone Controllers FMH-FC-SUPER3 Models Model Voltage FMH-220-FC-Super3 220VAC FMH-110-FC-Super3 110VAC Wiring diagram 5-2 www.meitavtec.com | [email protected] Fan Coil Stand Alone Controllers FMH220-P-FC-SUPER FC Flush-mount, 220VAC thermostat, with 0-10V proportional outputs for Fan-Coil valves and 3 Fan speeds COOL The FMH220-P-FC-SUPER is a highly versatile thermostat for Fan Coil applications. With numerous configuration options, HEAT it is an ideal solution for wholesalers to keep on stock and supply the proper configuration according to customer's ECONOMY specifications. 0-10V This superior, energy saving thermostat offers 2 proportional outputs for Cool & Heat, with a configurable, OUTPUT proportional opening. It also enables choosing various configuration options using DIP switches, to suit to customer's requirements. For example, seller can configure it to a 2-Pipe or a 4-Pipe application, with or without Auto-Change-Over mode, 1 or 3 fan speeds, or alternatively, internal / external sensor. Other important features, such as Economy mode, temperature offset, dead zone and set point limits are also adjustable. This versatility makes the FMH220-P-FC-SUPER the ultimate choice for comfortable, easy temperature control for AUTO CHANGE-OVER Fan-Coil. EXT. SENSOR OPTION Features y Flush mount, 220VAC thermostat (available also in 110VAC model) RT03 temp. only – DIP switch selectable y Applicable for various Fan Coil applications: 2 pipe / 4 pipe – DIP switch selectable y Internal / External sensor – DIP switch TIMER selectable y 2 separate proportional outputs for Cool and Heat (configurable, proportional opening -0-10V) y Hand held remote control – option LOCK OPT. y Timer – ideal when you are asleep or away y Auto change over sensor or contact input – DIP switch selectable y Adjustable set point limits - 10°…30°C y Economy mode y 1 or 3 fan speeds – DIP switch selectable y With / without Auto-change-over mode – DIP switch selectable y Always Auto-Fan /Auto-Fan selectable – DIP switch selectable y Set point & room temp. display / set point y Lock buttons – option y Offset – adjustable y Beeping pushbuttons - optional Fan (3A) Wiring diagram 3 2 1 L 4-Pipe configuration N High voltage wires W (or) 2-Pipe configuration (or) No valve – fan only Not connected Heat valve 0 Y Cool valve One valve Not connected T2 Contact input (remote switch) or Auto-change over sensor 0 External sensor (option) T1 www.meitavtec.com | [email protected] 5-3 Fan Coil Stand Alone Controllers MIGA1-FC-SUPER Main Controller for Fan Coil applications, with FC optional hand-held remote control +IR panel, or wall or flush mount panels. MIGA1-FC-SUPER is a main controller for various F/C applications. Together with a wall or flush mount HEAT thermostat panel or receiver and a remote control - this controller becomes highly attractive and an ideal 'general purpose controller'. MIGA1-FC-SUPER has a modular, user-friendly design AUTO FAN with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it according to EXT. SENSOR OPTION customer’s needs on the spot. Meitav-tec's best seller for years – highly reliable and user friendly both for installers and customers. FAULT INPUT Features TIMER y Main Supply – 230VAC y Auto-Fan in Heat and Fan-On in Cool / y Various F/C application, jumper selectable: Fan in no valves – jumper selectable * 2 pipe systems y 3 fan speeds * 4 pipe systems y Wall or flush mount thermostats – y No valve systems option y Hand-Held Remote Control + IRP or y T1 – Return Air Sensor y Auto-Change Over sensor (for 2-pipes) - sticker panel – option y Swing motor output - dry contact T2<20°C – Cool, T2>20°C – Heat - Option y Pump output – active in Cool mode y Indoor coil sensor - T3 >30°C – Fan starts y Timer – Start/Stop, programmable T3< 27°C Fan stops - Option y Fault input, dry contact – when contact opens, unit from R.Control 5-4 www.meitavtec.com | [email protected] Indoor coil sensor Auto change over sensor Return air sensor Cool (1A) Swing motor Output (dry contact) Low Medium High External fan (3A) Wiring diagram Heat (1A) turns off and warning, indications lights will flash C RT03 Accessories for MIGA1 ETN-MIGA-IR FC User interface for MIGA1 main board, with IR option AC The ETN-MIG-IR is a convenient user-interface for the MIGA1 main board. It is a wall mount, local control panel with an infra-red receiver option, making it ideal for any end-user. The ETN-MIG-IR is a smart looking thermostat panel with a ECONOMY soft aesthetic shape and a large, easy to read LCD display. TIMER RT03 Features y Easy connection to MIGA1 main board (3 wires only!) y Local Control of: y Energy Saving – cost efficient, Environmental Friendly logic * ON/OFF y Large, easy to read display * Mode y Soft, silicon pushbuttons * Fan Speed * ON/OFF Timer y Neutral, aesthetic color Wiring diagram www.meitavtec.com | [email protected] 5-5 Accessories for MIGA1 FMH-MIGA-IR Flush mount, thermostat panel, serving as a user interface for Meitav-tec's MIGA1 main board, with an IR receiver option. COOL The FMH-MIGA-IR is a flush mount, thermostat panel, functioning as a user interface for MIGA1 HEAT main board. It is a convenient local control panel with an infrared receiver option, making it ideal for any end-user. The FMH-MIGA-IR is a smart looking thermostat with a soft aesthetic shape and a large, easy to read LCD display. ECONOMY Features y Flush mount, 12VDC thermostat y 3 fan speeds + Auto y Easy connection to MIGA1 main board (3 wire y Temperature set point limits – 10…30°C only!) y Local Control of: * On/Off y IR option y Real time clock and day * Mode y Large & easy to read display * Set point temperature y Silicon rubber key pads * Fan Speed y Modes: Cool / Heat /Auto /Fan only Wiring diagram 5-6 C www.meitavtec.com | [email protected] y Simple & friendly setting Accessories for MIGA1 M1P IR Sticker Receiver Panel for MIGA1 main board The M1P is a wall mount, infrared sticker receiver panel, with a quick connector to MIGA1 main board. HEAT It can be locally controlled via its On/Off button, or via an IR Remote Control (RT03). TIMER The M1P can be supplied with an 80cm extension cable RT03 Features y Easily connected to MIGA1 main board using a quick y LED Indications: connector * ON/OFF y Locally Controlled: * Timer * On/Off * Power y Remotely Controlled: * On/Off * Heat/Cool y Suitable for Meitav'tec's MIGA controllers * Mode * Fan Speed * On/Off Timer M101P Plastic Panel Receiver for MIGA1 main board COOL The M101P is a wall mount, infra-red receiver panel, with a cable connector to MIGA1 main board. HEAT It can be locally controlled via its On/Off button, or via an IR Remote Control (RT03). AUTO FAN Features y Easily connected to MIGA1 main board y Locally Controlled: * On/Off TIMER y Remotely Controlled: * On/Off RT03 * Mode y LED Indication for Fault / Alarm * Fan Speed y Suitable for Meitav-tec's MIGA controllers * Temperature set-point Auto-Fan * Timer * Real Time Clock www.meitavtec.com | [email protected] 5-7 Fan Coil Stand Alone Controllers FMH-FC-SUPER4 Flush-Mount, 230VAC or 110VAC Thermostat for all Fan Coil applications, with a special contact input. FC The FMH-FC-SUPER4 is a highly versatile thermostat suitable for various Fan Coil applications. It can be flushmounted or installed directly into the Fan Coil, with an external sensor for the return air and water temperature. The FMH-FC-SUPER4 also offers several DIP Switch selectable options to best suit customer's needs, e.g. AutoChange-Over sensor, Soft-start for fan or a Contact Input. When the special contact input is selected, it allows 1 of 3 options: 1- Contact input for a remote switch, which changes the Mode of one or many thermostats linked. 2- Contact input for a remote switch that activates Economy mode. 3- Contact input to turn units off. Features y Flush-Mount, 230VAC or 110VAC, Thermostat y Suitable to various Fan Coil systems: * 4 pipe system – 2 valves y Special Contact Input (remote switch - close/ open) can be set to work in one of the following modes: FAULT INPUT * Mode selection – remote switch sets the mode (Cool/Heat) to one or more thermostats linked together (ideal for hotel bedrooms or offices). * 2 pipe system – 1 valve * Fan Coil – no valve y Modes: Cool, Heat, Auto, Fan Only * Economy Mode - unit reverts to predefined economy set points y 3 fan speed control + Auto y DIP switch control options: * Auto-Change-Over sensor & Fan SoftStart in Heat / Contact input * Display of set temperatures only / Display of set-point & room temp. * Contact input to turn the unit Off y Soft-Start logic in Heat for the Fan – adjustable delay time y T2 soft-start in Cool & Heat – adjustable temperature to start fan * Always Auto-Fan / Auto-Fan selectable y Cool/Heat temp. Dead Zone setting * With / without Auto-Change-Over mode y Energy saving – cost efficient, environmental friendly thermostat * Internal / External sensor y Auto-change over sensor - mode is set based on temperature of the incoming water flow, ideal for 2-pipe systems. y Offset - ±6°C y Lock buttons – option y Set point limits – 10°…30°C y Remote control– optional (RT03) Wiring diagram 5-8 AUTO CHANGE-OVER www.meitavtec.com | [email protected] Models Model Voltage FMH-220-FC-Super4 220VAC FMH-110-FC-Super4 110VAC EXT. SENSOR OPTION Fan Coil Controllers MIGA AB FC MIGA AB enables control of multiple fan-coil controllers, linked one to another, via a main panel. Ideal for open space applications, where all controllers need the same working parameters. COOL MIGA-AB controller is a smart, cost effective solution for HEAT multiple fan-coil control. ETN/MIGA AB master panel allows control of up to 60 MIGA controllers, which need the same working conditions. Each MIGA board controls temperature according to the orders received from the master ETN/MIGA AB, but works according to its local ambient temperature, measured by its temperature sensors. AUTO FAN It is, therefore, a great solution for open spaces, such as banks, large stores and similar applications where one AUTO CHANGE-OVER set of parameters suits all fan-coil units. MIGA AB, together with a wall or flush mount panel, is a convenient, easy way to operate numerous fan coil ECONOMY controllers. C Features y Main Supply – 230VAC y Optional panels for Master: Wall / flush-mount y Various F/C applications, jumper selectable: y Optional panels for slave: wall-mount, IR y y y y y y y * 2 pipe systems receiver (can override the main panel command * 4 pipe systems (Last operation rules). 3 fan speed control y Remote Control (RT03) Modes: Cool, Heat, Auto, Fan Only y Daily, Start-Stop timer (from remote control Mode is selected from master panel to all boards only) Communication to other MIGA boards y Economy T-set in Cool & Heat – adjustable T1 – Return Air Sensor y Offset - ±6°C T3- Soft-Start in Heat sensor When T3 is not connected, Auto-Fan mode in Heat is active, Auto-Fan in Cool is inactive y Condensing Pump output y Air Mixing algorithm in Heat (when set-point ≥ ambient temp.) y DIP switch selectable options in RT03 y Set point limits - 10°…30°C y Dead Zone, adjustable - 1…5°C y In 2-pipe systems, Aqua-Stat should be used between the valve outputs and the valve y DIP switch selectable options in WP2500/MIG/WS panel: ETN1000/MIGA/AB panel: * On-Off / Start-Stop configuration * Lock / Unlock panel buttons * Read ambient Temp. from panel / MIGA * On-Off / Start-Stop configuration * T-set + T ambient Display / T-set display only * Read ambient Temp. from panel / MIGA * Standard work / Technician work * T-set + T ambient Display / T-set display only * Standard work / Technician work www.meitavtec.com | [email protected] 5-9 Fan Coil Controllers MIGA AB Wiring diagram 5-10 www.meitavtec.com | [email protected] A/C Stand Alone Controllers MIGA1-AC-SUPER Main Controller for A/C applications, with optional AC hand-held remote control +IR panel, or wall or flush mount panels. COOL MIGA1-AC-SUPER is a main controller for various A/C applications. Together with a wall or flush mount thermostat panel or a receiver and a remote control - this controller becomes highly attractive, an ideal 'general purpose controller'. MIGA1-AC-SUPER has a modular, user-friendly design with AUTO FAN various A/C applications built-in, field selectable. This modularity allows you to have one main controller for AUTO CHANGE-OVER different A/C applications and suit it according to customer’s needs on the spot. HP/HC Features TIMER y Main controller for multi AC applications y 3 Fan speeds and Auto Speed y Main Input- 230VAC y Auto Fan – selectable y Jumper selectable applications y External fan output – option y Wall or Flush mount thermostats, Sticker Panel * Heat Pump (reversible) C EXT. SENSOR OPTION or IRP - option * Heat-Cool y External sensor – option y IR remote control - option y Return air sensor (T1) y Timer – Start/Stop, programmable by remote y Outdoor coil sensor (T2) option –in Heat mode, de- control y C° temperature display icing y Indoor coil sensor (T3) option – in Cool mode, de-icing Low Medium High External fan (3A) Heat element / Heat pump (1A) Compressor (1A) Wiring diagram www.meitavtec.com | [email protected] 6-1 Maxinet – Thermostat Network MCU Master Control Unit for stand alone applications or Maxinet Router for up to 60 thermostats The MCU is a Master Control Unit for stand-alone applications to control up to 60 thermostats or software applications. It is also applicable as a router for large PROG network applications in Maxinet B.M.S., or just for simple divisions in installations such as floors or large buildings. ECONOMY The MCU has an emergency weekly program that is C F activated automatically when the software is down. In addition, the MCU has a large display and pushbuttons to view and change units in the network. It allows broadcasting commands to all the units with a push of a button. Overall, the MCU offers features and solutions for the modern HVAC BMS market. Features y View and change units in the network y Easy to change each unit settings: * Mode y Emergency Weekly Program (EWP) , automatically activated when software is down y Weekly program for 7 days, with 2 times start-stop * Fan speeds time and set for each period when working as stand * Set temperature alone master * Set temperature limit * On/Off y Energy Saving – cost efficient, Environmental Friendly built-in logic y Connect up to 12 MCUs to one Maxinet software y DIP switch selection for stand alone or software application www.meitavtec.com | [email protected] 7-1 Maxinet-Thermostat Network ETN-C-24-SUPER-Maxinet protocol Wall mount, 24VAC thermostat for MaxiNet AC BMS system The ETN-C-24-Super is an attractive thermostat for COOL easy HVAC control with MaxiNet BMS system. Having most A/C applications built-in, field selectable and offering several stages of Cool and Heat and, the ETN-C-24-Super is suitable for either Heat/Cool or Heat Pump systems. B.M.S This flexibility, together with built in Maxinet protocol COMPATIBLE and energy saving algorithm make the ETN-C-24Super an easy, cost-effective solution for networking in small to medium sized BMS. C F Features y Wall mount, 24 VAC thermostat y Up to 3 stages for Heat & 2 stages for Cool y DIP switch selectable applications: y External sensor- option * Heat/Cool or Heat Pump COMPRESSOR DELAY y Selectable temperature scale - °C or °F * Electric Heat or Oil/Gas HP/HC y Set Point limits- 10…30°C, 50…86°F * Heat Pump in Heat or Heat Pump in Cool x MAC address configuration via DIP switches y Economy mode x MaxiNet Communication Built in y Easy to install and use EXT. SENSOR OPTION Wiring diagram Models Model ECONOMY Heating Stages Cooling Stages Speeds G ETN-C-24-HC11-1S 1 1 1 ETN-C-24-HC22-1S 2 2 1 ETN-C-24-HP11-1S 1 1 1 ETN-C-24-HP21-1S 2 1 1 ETN-C-24-HP32-1S 3 2 1 Fan (0.5A) A Communication (Maxinet) B T External sensor (option) To W2 B/O Heat element 2 / Heat pump (0.5A) W1 Heat element 1 (0.5A) Y2 Compressor 2 (0.5A) Y1 Compressor 1 (0.5A) C Main Input 24VAC R 7-2 www.meitavtec.com | [email protected] MaxiNet-Thermostat Network PS1800-AC-SUPER - MaxiNet protocol Main Controller for A/C in Building Management B.M.S System (BMS) application, with Maxinet protocol COMPATIBLE The PS1800-AC-SUPER is a main controller, with COMM MaxiNet Protocol, for A/C MaxiNet BMS applications. It AC has a modular, user-friendly design with various A/C applications built-in, field selectable. This modularity allows you to have one main controller for different A/C applications and suit it according to customer’s needs COOL on the spot. The PS1800-AC-SUPER also offers cost efficient HEAT capabilities, such as, occupancy sensor, cooling stages and smart algorithm for maximum energy saving. The PS1800-AC-SUPER is factory pre-programmed to save valued time on field programming. Please note the PS-1800 is also available as a CTU-1800, with additional advanced features. HP/HC Features y Main controller for multi AC applications y Main Input- 230VAC y Outputs may be 230VAC or any other according to the phase input (WET terminology) y User Selectable applications: * Heat/Cool or Heat Pump (HC/HP) * Electric Heat or Oil/Gas * Heat Pump in Heat or Heat Pump in Cool y Up to 3 stages of Heat and 2 stages of Cool y 3.5 minute delay for compressor - Jumper selectable y 1 or 3 fan speed control - Jumper selectable y 3 x Temperature sensor inputs: * T1 sensor - Return Air sensor * T2 sensor - Outdoor sensor for Deicing in heat mode, or Overheat protection in cool mode * T3 sensor - Indoor sensor for Deicing in cool mode, or Overheat protection in heat mode y 3 x Fault input, dry contact, voltage-free, Normally Closed: * Fault 1 – for indication through protocol y Occupancy Sensor input- 12VDC supply AUTO CHANGE-OVER * Normally Closed input, Active when open * Work options – Off / Economy Set point COMPRESSOR DELAY y Economy set-point – adjustable y Time IR sensor starts its work options - adjustable y Window Contact input – (F2) ECONOMY EXT. SENSOR OPTION * Turn Off all outputs when open y Flow Sensor input – (F3) * Normally Closed input, Active when open * When open, compressor & heating outputs FAULT INPUT C F turn off y Celsius or Fahrenheit temperature display RT03 y Ambient Temperature reading from panel or from main board - selectable y Wall or flush mount panels available y Lock pushbuttons - option y Offset for temperature reading – through room panel y Set point limits - 10°…30°C , 50…86 oF * Fault 2 - for Window contact (N.C.) y Dead Zone, adjustable - 0…5°C , 0…12 oF * Fault 3 – for Flow sensor y Offset - ±6°C adjustable www.meitavtec.com | [email protected] 7-3 Configurations Main Panel PS1800-AC-SUPER OR TS-01 sensor only (No Panel) OR IRP-X500-02 OR FMH-X500-02 Control Panels/Accessories Wiring diagram 7-4 www.meitavtec.com | [email protected] ETN-X500-02 Maxinet-Thermostat Network PS1800-FC-SUPER - Maxinet protocol Main Controller for Fan-Coil in B.M.S. (Building Management System) applications, with Maxinet Protocol The PS1800-FC-SUPER is a main controller, with Maxinet Protocol, for Fan Coil applications, suitable for COMM Maxinet mini Building Management System (BMS). It has a modular, user-friendly design with various Fan Coil applications built-in, field COOL selectable. This modularity allows you to have one main controller HEAT for different Fan Coil applications and suit it according to customer’s needs on the spot. The PS1800-FC-SUPER also offers cost efficient capabilities, such as occupancy sensor, window contact AUTO FAN fault input and auto-change-over for maximum energy saving. ECONOMY The PS1800-FC-SUPER is factory pre-programmed to save valued time on field programming. AUTO CHANGE-OVER Please note the PS-1800 is also available as a C CTU-1800, with additional advanced features. FAULT INPUT Features y Main controller for multi Fan Coil applications y Main Input- 230VAC y Applications with jumper selection: y Energy saving – cost efficient, environmental friendly controller y Indoor coil sensor input for Heat (soft-start) * 2-pipe systems y Return Air sensor * 4-pipe systems y 3 Speed output - 230VAC, 3Amp + Auto Speed * no valve system y ON/OFF output for Cool and Heat valves y Pump output – synchronized with Cool output y Auto-change over sensor input - Mode is set based EXT. SENSOR OPTION RT03 y Wall and flush mount panels – option y Auto Fan – selectable y Occupancy sensor input - with 12VDC supply on temperature of the incoming water flow, ideal for * Normally Closed input, Active when open 2-pipe systems * Work options – Off / Economy Set point www.meitavtec.com | [email protected] 7-5 7-6 www.meitavtec.com | [email protected] Communication Maxinet protocol Low Medium High Heat (1A) Cool (1A) ETN-X500 Fault 2 (indication through protocol) Enable fan only mode Pump output (1A) Not in use OR Fault 1 (open – all outputs off) Not in use Not in use FMH-X500 Not in use Not in use Indoor coil sensor Not in use OR Not in use Changeover sensor Not in use Return air sensor Maxinet-Thermostat Network PS1800-FC-SUPER - Maxinet protocol Configurations Main Panel PS1800 OR FMT-X500 IRP-X500 Control Panels/Accessories Wiring diagram Maxinet-Thermostat Network PS1800-P-FC-SUPER - Maxinet protocol Main Controller for Fan-Coil in B.M.S. (Building Management System) applications, with Maxinet Protocol The PS1800-P-FC-SUPER is a main controller, with Maxinet Protocol, for Fan Coil proportional applications, suitable for Maxinet mini Building COMM Management System (B.M.S.). It has a modular, user-friendly design with various Fan Coil applications built-in, field COOL selectable. This modularity allows you to have one main controller HEAT for different Fan Coil applications and suit it according to customer’s needs on the spot. The PS1800-P-FC-SUPER also offers cost efficient capabilities, such as occupancy sensor, window contact fault input and auto-change-over for maximum energy saving. AUTO FAN The PS1800-P-FC-SUPER is factory pre-programmed to save valued time on field programming. Please note the PS-1800 is also available as a CTU-1800, with additional advanced features. Features y Main controller for multi Fan Coil applications y 3 Speed output - 230VAC, 3Amp + Auto Speed y Main Input- 230VAC y Energy saving – cost efficient, environmental y Applications with jumper selection: friendly controller * 2-pipe systems y °C or °F temperature scale – jumper selectable * 4-pipe systems y Wall or flush mount panels – option * no valve system y Proportional outputs (0-10VDC or 2-10VDC) for Cool & Heat valves y Condensing Pump output – synchronized with Cool output y Auto-change over sensor input - Mode is set based on temperature of the incoming water flow, ideal for 2-pipe systems RT03 y Auto Fan – selectable y Occupancy sensor input - with 12VDC supply y Normally Closed input, Active when open y Fault input, dry contact, voltage free for occupancy sensor, window contact or fault input y Limit Cool/Heat set points – 10…30°C/50..86° F y Offset - -6…+6°C / -12…+12°F y Indoor coil sensor input for Heat (soft-start) y Return Air sensor www.meitavtec.com | [email protected] 7-7 Maxinet-Thermostat Network PS1800-P-FC-SUPER - Maxinet protocol Configurations Main Panel PS1800 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories Wiring diagram Fan (230VAC, 3A) Main input 230VAC N ~ 0 PR Occupancy sensor Y 0 0 F1 0 0 W F2 HEAT 13 0 F3 0 12 11 F4 0 Not in use 7-8 www.meitavtec.com | [email protected] T1 F5 0 0 T2 F6 0 T3 0 Y 0 1 IR -12V +12V 2 3 8 Room panel (option) 7 Not in use P1 P2 A P3 B Maxinet – Thermostat network PS-1800-PM2-3S-FC-SUPER - Maxinet protocol Main Controller for B.M.S Maxinet, Fan-Coil B.M.S COMPATIBLE applications, with pulse modulating outputs for Cool & Heat valves, with Maxinet protocol. COMM The PS-1800-PM2-3S-FC-SUPER is a main controller, with FC Maxinet protocol, for Fan Coil applications, suitable for Maxinet B.M.S. (Building Management System). COOL It has a modular, user-friendly design with various Fan Coil applications built-in, field selectable. This modularity allows you to have one main controller for different Fan Coil HEAT applications and suit it according to customer’s needs on the 3-WIRE OUTPUT spot. The PS-1800-PM2-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor and fault inputs for maximum energy saving. The PS 1800-PM2-3S-FC-SUPER is factory pre-programmed AUTO FAN to save valued time for the installers on field programming. Please note the PS-1800 is also available as a CTU1800, with additional advanced features. FAULT INPUT EXT. SENSOR OPTION Features y Energy saving – cost efficient, environmental y Main Input- 230VAC friendly controller ECONOMY y F/C Applications - jumper selectable: * 2-pipe system y Condensing Pump output - * 4-pipe system synchronized RT03 with Cool output y Pulse Modulating outputs (floating / 3-wire) for Cool and Heat valves - 24VAC y Wall and flush mount thermostats- option (opening / closing duration - adjustable) y Auto-change-over sensor (Mode is set based on temperature of the incoming water flow, ideal for 2-pipe systems) y Indoor coil sensor input for Heat (soft-start) y Fault input - dry contact, voltage-free, for occupancy sensor y Occupancy sensor input - 12VDC supply Normally Closed, active when Open y Set point limits - 10°…30°C y IR input y Return Air sensor y 3 Speed output- 230VAC, 3Amp + Auto Speed feature y Auto Fan option www.meitavtec.com | [email protected] 7-9 Maxinet – Thermostat network PS-1800-PM2-3S-FC-SUPER - Maxinet protocol Configurations Main Panel PS1800 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories (24VAC, 2.5VA) (24VAC, 2.5VA) www.meitavtec.com | [email protected] 0 F1 Indoor coil sensor 0 0 T3 F2 IR -12V +12V 0 0 Valve open/close time F3 0 F4 0 F5 1 2 0 F6 Fault F2 PR T2 Room panel (option) 3 8 7 A B Communication Maxinet protocol Cool Valve 0 0 Enable fan only mode Heat Valve T1 Occupancy sensor Fault F1 Open Close Common CL1 OP1 COM COM CL2 OP2 Common C Open R Change over sensor 11 PUMP Close Return air sensor Low 12 L Not in use 13 N 24VAC input (for valves) 7-10 Medium Main input 230VAC Fan (230VAC, 3A) High Condensing pump (230VAC, 1A) Wiring diagram Maxinet – Thermostat network CTU1800-PM2-3S-FC-SUPER - Maxinet protocol Main Controller for B.M.S Maxinet, Fan-Coil B.M.S COMPATIBLE applications , with pulse modulating outputs for Cool & Heat valves, with Maxinet protocol COMM The CTU1800-PM2-3S-FC-SUPER is a main controller, with Maxinet protocol, for Fan Coil applications, suitable for Maxinet B.M.S. (Building Management System). It has a modular, user-friendly design with various Fan Coil applications built-in, field selectable. This modularity allows you to have one main controller for different Fan Coil applications and suit it according to customer’s needs on the spot. The CTU 1800-PM2-3S-FC-SUPER also offers cost efficient 3-WIRE OUTPUT capabilities, such as, occupancy sensor and fault inputs for maximum energy saving. The CTU1800-PM2-3S-FC-SUPER is factory pre-programmed to save valued time for the installers on field programming. Features y Main Input- 230VAC y F/C Applications - jumper selectable: * 2-pipe system * 4-pipe system y Energy saving – cost efficient, environmental AUTO CHANGE-OVER friendly controller y Wall and flush mount thermostats- option y Condensing Pump output - synchronized with EXT. SENSOR OPTION Cool output y Pulse Modulating outputs (floating / 3-wire) for Cool and Heat valves- 24VAC (opening/closing duration adjustable) y Auto-change-over sensor (Mode is set based on temperature of the incoming water flow, ideal for 2-pipe systems) ECONOMY y Fault input - dry contact, voltage-free, for occupancy sensor y Occupancy sensor input - 12VDC supply Normally Closed, active when Open y Set point limits - 10°…30°C y Indoor coil sensor input for Heat (soft-start) y IR input y Return Air sensor y CE certification y 3 Speed output- 230VAC, 3Amp + Auto Speed feature y Modern design (functional and esthetical) y Auto Fan option y Connect to DIN rail www.meitavtec.com | [email protected] 7-11 Maxinet – Thermostat network CTU1800-PM2-3S-FC-SUPER - Maxinet protocol Configurations Main Panel OR OR FMH-X500 OR ETN-X500 FMT-X500 Control Panels/Accessories Wiring diagram 7-12 www.meitavtec.com | [email protected] IRP-X500 Maxinet – Thermostat Network CTU1601 - Maxinet protocol Input  Output card for Maxinet system with 8 B.M.S outputs 230V, 8 inputs dry contact and 3 COMPATIBLE Temperature readings COMM The CTU-1601 is an Input  Output (IO) card for Maxinet EXT. SENSOR OPTION system. It has 8 inputs, dry contact to view the status of various devices, and 8 outputs 230V 0.5A, to manage general devices from the Maxinet software, such as: - Air compressor - Chiller - Fresh air damper - Lights - Outdoor lights - Extractors - Fans The 8 outputs can be weekly programmed from the software very easily. In addition, the CTU-1601 offers 3 Temperature sensor inputs, enabling to see temperatures in 3 locations. Features y 8 Digital outputs – 230 V, 0.5 A y Works with Maxinet Software y 8 Digital inputs – volt free – dry contact y Easy connection to Din Rail y 3 Temperature readings Wiring diagram www.meitavtec.com | [email protected] 7-13 Maxinet-Thermostat Network PS1600 - Maxinet protocol Output card for Maxinet system, with up to 8 outputs – dry contact B.M.S COMPATIBLE The PS-1600 is an output card for Maxinet mini COMM B.M.S. system. It has 8 outputs, dry contact, to control energy consuming devices / systems, ECONOMY connected to Maxinet system, such as: y Air compressor y Fresh air damper y Lights y Outdoor lights y Extractors y Fans These outputs can be viewed, controlled and monitored from the Maxinet software and can also be easily weekly programmed. Features y 8 outputs - dry contact, normally open y Up to 16 units per network y Works with Maxinet Software y 12VDC operating voltage y PS201P as power supplier Wiring diagram 7-14 www.meitavtec.com | [email protected] Maxinet-Thermostat Network PS1800-FC-SUPER-02 - Maxinet protocol Main Controller for Fan-Coil in B.M.S. (Building B.M.S Management System) applications, with Maxinet COMPATIBLE Protocol and with special 'room circulation' feature for Energy Saving. The PS1800-FC-SUPER is a main controller, with Maxinet Protocol, for Fan Coil applications, suitable for Maxinet mini Building Management System (BMS). It has a modular, userfriendly design with various Fan Coil applications built-in, field selectable. This modularity allows you to have one main HEAT controller for different Fan Coil applications and suit it according to customer’s needs on the spot. Aside from cost efficient capabilities, such as Occupancy Sensor and Window Contact, the PS1800-FC-SUPER also ECONOMY offers additional feature for maximum energy saving, 'Air Circulation in Heat'. This function allows mixing of hot air AUTO FAN available in a room with cold air when heating is required. The PS1800-FC-SUPER is factory pre-programmed to save RT03 valued time on field programming. AUTO CHANGE-OVER Features y Main Input- 230VAC y 3 Speed output - 230VAC, 3Amp + Auto y Main controller for Fan Coil applications, jumper y Wall selectable: * 2-pipe systems * 4-pipe systems * no valve system y ON/OFF output for Cool and Heat valves y Air mixing algorithm in Heat (room circulation) or Flush mount panel (the PS requires X500/02 panels) – option y Auto Fan – jumper selectable y Fan Only – jumper selectable y Occupancy sensor input - with 12VDC supply * Normally Closed input, Active when open * Work options – Off y Lock panel buttons (partially or fully) y Occupancy sensor delay time – 0-20 minutes y Condensing Pump output – synchronized with Cool y Cool & Heat dead zone – default 1°C, output range 0-5°C y Return Air sensor y Temp. limits – 10 - 30°C y Auto-change over sensor input - Mode is set based on y Offset of Ambient Temperature – ±6°C range temperature of the incoming water flow, ideal for 2pipe systems y Indoor C y Energy saving – cost efficient, environmental friendly coil sensor input for Heat (soft-start). Temperature for Fan Soft-Start - adjustable www.meitavtec.com | [email protected] 7-15 7-16 www.meitavtec.com | [email protected] Communication Modbus protocol Indoor coil sensor Change over sensor ETN-X500-02 Not in use Return air sensor Low OR Fault 6 (N/C) - for indication through software Enable/ Disable fan only mode FMH-X500-02 Medium High Heat (230VAC,1A) Cool (230VAC,1A) Pump Output (230VAC,1A) OR Fault 4 (N/C) – when open – all outputs off with no delay Fault 3 (N/O) – for indication through software Fault 2 (N/O) – Pump indication for indication through software Fault 1 (N/O) – for indication through software Maxinet-Thermostat Network PS1800-FC-SUPER-02 - Maxinet protocol Configurations Main Panel PS1800 OR FMT-X500-02 IRP-X500-02 Control Panels/Accessories Wiring diagram Communication PS2500-3S-FC-SUPER –BACnet Protocol Main Controller for Fan Coil, Building Management FC System (B.M.S.) applications, with BACnet protocol (RS-485), with outputs for Cool & Heat B.M.S COMPATIBLE The PS2500-FC-SUPER is a main controller for Fan coil B.M.S. applications with BACnet Protocol. It has a modular, user- COMM friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main COOL controller for different F/C applications and suit it according to customer’s needs on the spot. HEAT The PS2500-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor or window contact inputs, auto-changeover and smart algorithm for maximum energy saving. The PS2500-FC-SUPER is factory pre-programmed to save AUTO FAN valued time on field programming. Please note the PS-2500 is also available as a CTU product with additional advanced features. Features y Main Input- 220VAC (available also in 110VAC) y Main controller for various Fan Coil applications, jumper selectable: y Environmental friendly & economic – with smart algorithm for maximum energy saving y Fan Only - selectable * 2-pipe systems y Wall or flush mount panel- option * 4-pipe systems y 2 Fault inputs - dry contact, voltage-free, for * no valve system y On/Off output for Cool and Heat valves – 220VAC y Auto-change over sensor (Mode is set based on temperature of the incoming water flow, ideal for 2-pipe systems) - selectable y Indoor coil sensor for Heat (soft-start) - optional y Condensing Pump output occupancy sensor, window contact or fault input - for indication through protocol F FAULT INPUT RT03 EXT. SENSOR OPTION y °T ambient reading from panel or external sensor - DIP switch selectable y Auto-Fan / Fan-On – jumper selectable y Occupancy sensor input + 12V power supply to the sensor y °C or °F temperature scale y Temperature set point limits – 10…30°C y 3 fan speeds - 220VAC, 3Amp. each- with Auto Speed y Offset - +/-6°C function C y IR input www.meitavtec.com | [email protected] 8-1 Communication PS2500-3S-FC-SUPER – BACnet Protocol Configurations Main Panel PS2500 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories 8-2 0 Device Instance Number (DIN) F3 0 11 F4 www.meitavtec.com | [email protected] 0 F5 T1 0 F6 0 T2 Indoor coil sensor Low 12 Change over sensor Return air sensor Medium 13 0 Y T3 0 Occupancy sensor IR -12V +12V 0 1 2 3 8 Room panel (option) 7 Not in use P1 P2 P3 A B Communication BACnet protocol F2 14 Not in use 0 15 Fault 2 (indication through protocol) F1 16 Enable fan only mode 0 Heat (230VAC,1A) PR X1 High 0 N.O1 N.C1 X2 Cool (230VAC,1A) ~ Temperature scale N Not in use Fan (230VAC, 3A) Fault 1 (open – all outputs off) Main input 230VAC Pump Output (230VAC,1A) Wiring diagram Communication PS2500-P-3S-FC-SUPER – BACnet Protocol Main Controller for Fan Coil in Building Management System (B.M.S.) applications, with RS-485 BACnet protocol and proportional (0-10V) outputs for the Fan-Coil valves The PS2500-P-3S-FC-SUPER is a main controller for Fan coil in B.M.S. applications with BACnet Protocol. It has a COOL modular, user-friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it according to customer’s needs on the spot. The PS2500-P-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor or window contact inputs, auto-change-over and smart algorithm for maximum C energy saving. The PS 2500-P-3S-FC-SUPER is factory pre-programmed to save valued time on field programming. Please note the PS-2500 is also available as a CTU-2500, COMM with additional advanced features. FAULT INPUT Features y Main Input – 220VAC y 3 Speeds output – 220VAC, 3Amp each – AUTO CHANGE-OVER with Auto Speed function y Various F/C applications, jumper selectable: * 2-pipe systems y Wall & flush mount panels – option * 4-pipe systems y Fault input dry contact, voltage-free, for * no valve system ECONOMY RT03 Occupancy sensor y Proportional outputs (0-10V or 2-10V) for the Cool and Heat valves. y Occupancy Sensor – 12VDC supply y IR input y T1 sensor – Return Air Sensor y T2 sensor – Auto-change over sensor (Mode is set based y Condensing Pump output – -230VAC, 1A (active in Cool) on temperature of the incoming water flow, ideal for 2- y Offset pipe systems) y T3 sensor – Indoor coil sensor for Heat (soft-start) y Fault input, dry contact, voltage-free – Normally Closed, when open all outputs are OFF for temperature reading – through room panel y Set point limits - 10°…30°C Energy saving – cost efficient, environmental friendly algorithms www.meitavtec.com | [email protected] 8-3 Communication PS2500-P-3S-FC-SUPER – BACnet Protocol Configurations Main Panel PS2500 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories Wiring diagram Fan (230VAC, 3A) Main input 230VAC N ~ 0 PR Occupancy sensor Y 0 0 F1 0 0 W F2 HEAT 13 0 F3 0 12 11 F4 0 Device Instance Number (DIN) 8-4 www.meitavtec.com | [email protected] T1 F5 0 0 T2 F6 0 T3 0 Y 0 1 IR -12V +12V 2 3 8 Room panel (option) 7 Not in use P1 P2 A P3 B Communication PS2500-PM2-3S-FC-SUPER – BACnet Protocol Main Controller for Fan Coil, Building Management System (B.M.S.) applications, with RS-485 MSTP Native BACnet protocol, with 3-wire, Proportional outputs for Cool & Heat The PS2500-PM-3S-FC-SUPER is a main controller for Fan COOL coil B.M.S. applications with MSTP BACnet Protocol. It has a modular, user-friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it according to customer’s needs on the spot. The PS2500-PM-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor or window contact inputs and smart algorithm for maximum energy saving. The PS 2500-PM-3S-FC-SUPER is factory pre-programmed 3-WIRE OUTPUT to save valued time on field programming – just Plug and activate without additional settings or programming. Please note the PS-2500 is also available as a CTU-2500, with additional advanced features. Features y Main Input- 220VAC y Various F/C Applications - jumper selectable * 2-pipe systems * 4-pipe systems * no valve system y Proportional outputs (3-wire) for Cool & Heat valves, 24VAC with external transformer (Open/Close time adjustable through protocol) y 3 Speeds output- 220VAC, 3Amp each- with Auto Speed function y T1 sensor – Return Air Sensor y T2 sensor - Auto-Change Over sensor (Mode is set y Fault input, dry contact, voltage-free - Normally Closed, when open all outputs are Off y Fault input, dry contact, voltage-free – for indication through protocol y Energy Saving – cost efficient, environmental friendly logic and algorithms y Indoor coil sensor for Heat (soft-start) COMM y Wall or flush mount panels - optional y Fault input dry contact, voltage-free, for occupancy sensor, window contact or fault input y Auto-Fan based on temperature of the incoming water flow, y IR input ideal for 2-pipe systems) y Set point limits - 10°…30°C y T3 sensor - Indoor coil sensor (soft-start in Heat Mode) RT03 y Dead zone – 0…5C° www.meitavtec.com | [email protected] 8-5 8-6 www.meitavtec.com | [email protected] Communication BACnet protocol Fault 2 (indication through protocol) ETN-X500 Enable fan only mode Indoor coil sensor FMH-X500 Change over sensor Return air sensor OR Fault 1 (open – all outputs off) Not in use Medium Open OR Low High Not in use Close Common Common Open Close Communication PS2500-PM2-3S-FC-SUPER –BACnet Protocol Configurations Main Panel PS2500 OR FMT-X500 IRP-X500 Control Panels/Accessories Wiring diagram Communication PS2500-TA2-3S-FC-SUPER – BACnet Protocol Main Controller for Fan Coil, Building Management System FC (B.M.S.) applications, with BACnet protocol (RS-485), with Thermal Actuators, proportional outputs B.M.S COMPATIBLE The PS2500-TA2-3S-FC-SUPER is a main controller for Thermal Actuator, proportional Fan coil B.M.S. applications with BACnet COMM Protocol. It has a modular, user-friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it according to customer’s needs on the spot. HEAT The PS2500-TA2-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor or window contact inputs, auto-changeover and smart algorithm for maximum energy saving. The PS2500-TA2-3S-FC-SUPER is factory pre-programmed to save AUTO FAN valued time on field programming. Please note the PS-2500 is also available as a CTU product with AUTO CHANGE-OVER additional advanced features. ECONOMY Features y Main Input- 220VAC y Main controller for various Fan Coil applications, jumper selectable: * 2-pipe systems * 4-pipe systems * no valve system y Proportional output for thermal actuators on 220VAC y Auto-change over sensor (Mode is set based on y Environmental friendly & economic – with smart algorithm for maximum energy saving C FAULT INPUT y Fan Only – jumper selectable y 3 fan speeds - 220VAC, 3Amp each- with RT03 Auto Speed function y Wall or flush mount panels - option y °T ambient reading from panel or main board - DIP switch selectable temperature of the incoming water flow, ideal for 2-pipe systems) - Selectable y Discharge sensor – option (2-pipe system) y Indoor coil sensor for Heat (soft-start) y 2 Fault inputs - dry contact, voltage-free, for y Auto-Fan or Fan-On – jumper selectable y Occupancy sensor–option with 12VDC supply y Temperature set point limits – 10…30°C occupancy sensor, window contact or fault input - for y Offset - +/-6°C indication through protocol y IR input www.meitavtec.com | [email protected] 8-7 8-8 www.meitavtec.com | [email protected] Communication BACnet protocol Fault 2 (indication through protocol) Enable fan only mode ETN-X500 Fault 1 (open – all outputs off) Indoor coil sensor OR Change over sensor FMH-X500 Return air sensor Low Medium High OR Not in use Not in use Not in use Communication PS2500-TA2-3S-FC-SUPER – BACnet Protocol Configurations Main Panel PS2500 OR FMT-X500 IRP-X500 Control Panels/Accessories Wiring diagram Communication CTU2500-P-3S-FC-SUPER – BACnet Protocol Main Controller for Fan Coil in Building Management System (B.M.S.) applications, with RS-485 BACnet protocol and proportional (0-10V) outputs for the Fan-Coil valves The CTU2500-P-3S-FC-SUPER is a main controller for Fan coil in B.M.S. applications with BACnet Protocol. It has a modular, user-friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it HEAT according to customer’s needs on the spot. 0-10V The CTU2500-P-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor or window contact OUTPUT inputs, auto-change-over and smart algorithm for maximum energy saving. The CTU2500-P-3S-FC-SUPER is factory pre-programmed to save valued time on field programming. C Features y Main Input- 220VAC y F/C applications, DIP switch selectable: * 2-pipe systems * 4-pipe systems y Proportional outputs (0-10V or 2-10V) for Cool & Heat valves. y T1 sensor – Return Air Sensor y T2 sensor - Auto-change over sensor (Mode is set based on temperature of the incoming water flow, ideal for 2pipe systems) y Energy saving – cost efficient, environmental friendly algorithms y Occupancy Sensor (12VDC supply) – adjustable 0…3600 sec. y Fan On/Auto-Fan in Cool or Heat – DIP switch y Condensing Pump output -230VAC, 1A (active in Cool) y Offset for temperature reading - -6…+6°C through room panel y Set point limits - 10°…30°C y Fault (1) input, dry contact, voltage-free - Normally y Dead Zone – 0…5°C y Fault (2) input dry contact, voltage-free, for Occupancy Sensor y 3 Speeds output- 220VAC, 3Amp each with Auto Speed function y Fan Only - selectable FAULT INPUT selectable y T3 sensor - Indoor coil sensor for Heat (soft-start) Closed, when open all outputs turn off AUTO FAN RT03 y Wall & flush mount panels, or IR panel option y IR input y DIN rail mountable y CE certified www.meitavtec.com | [email protected] 8-9 Communication CTU2500-P-3S-FC-SUPER – BACnet Protocol Configurations Main Panel CTU2500 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories 0 DI2 DI3 8-10 www.meitavtec.com | [email protected] 0 12V 3 7 8 T1 0 T2 0 Out 0-10V (Cool) Out 0-10V (Heat) Low DI8 12VDC supply voltage – option (30mA max) DI6 DI7 Occupancy sensor 0 Enable fan only mode DI4 DI5 Fault 1 (open – all outputs off) Not in use 0 2 AO1 0 AO2 T3 0 A B Communication BACnet protocol DI1 1 X1 DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 Indoor coil sensor V1 Change over sensor L Room panel (option) Return air sensor N Medium Not in use Fan 230VAC, 3A High Main input 230VAC Pump output (230VAC,1A) Wiring diagram Communication PS4500-3S-FC-SUPER –Modbus RTU Protocol Main Controller for Fan Coil in Building Management FC System (B.M.S.) applications, with RS-485 MODBUS protocol, With on-off outputs for Cool & Heat valves COMM The PS4500-3S-FC-SUPER is a main controller for Fan coil B.M.S. applications with MODBUS Protocol. It has a COOL modular, user-friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it according to customer’s needs on the spot. The PS4500-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor, fault inputs, auto- AUTO FAN change-over and smart algorithm for maximum energy saving. ECONOMY The PS4500-3S-FC-SUPER is factory pre-programmed to FAULT INPUT save valued time on field programming. Please note the PS-4500 is also available as a CTU-4500, C with additional advanced features. AUTO CHANGE-OVER Features y Main Input- 220VAC y Various Fan Coil applications - jumper selectable * 2-pipe systems * 4-pipe systems * no valve system y On/Off outputs for Cool and Heat valves y 3 Speeds output- 220VAC, 3Amp each- with Auto Speed function y T1 sensor – Return Air Sensor y T2 sensor - Auto-change over sensor (Mode is set based on temperature of the incoming water flow, ideal for y Energy saving – cost efficient, environmental friendly controller with economic energy saving algorithms y Fault input – N.C., for indication through protocol y Auto-Fan operation y Wall or flush mount panels and IR receiver y Occupancy sensor input and logic with built-in 12VDC supply for the sensor y Condensing Pump output – active in Cool operation 2-pipe systems) y T3 sensor - Indoor coil sensor for Heat (soft-start) y IR input y Fault input, dry contact, voltage-free - Normally Closed, when Open all outputs are OFF www.meitavtec.com | [email protected] 8-11 Communication PS4500-3S-FC-SUPER – Modbus RTU Protocol Configurations Main Panel PS4500 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories Not in use 8-12 F2 0 F3 0 11 F4 www.meitavtec.com | [email protected] 0 F5 T1 0 F6 0 T2 Indoor coil sensor Low 12 Change over sensor Return air sensor Medium 13 0 Y T3 0 Occupancy sensor IR -12V +12V 0 1 2 3 8 Room panel (option) 7 Not in use P1 P2 P3 A B Communication Modbus protocol 0 14 Not in use F1 15 Fault 2 (indication through protocol) 0 16 Enable fan only mode PR X1 Heat (230VAC,1A) 0 N.O1 N.C1 X2 High ~ Cool (230VAC,1A) N Not in use Fan (230VAC, 3A) Fault 1 (open – all outputs off) Main input 230VAC Pump Output (230VAC,1A) Wiring diagram Communication PS4500-P-3S-FC-SUPER - Modbus RTU Protocol Main Controller for Fan Coil, Building Management System (B.M.S.) applications, with Modbus protocol, and proportional outputs for Cool & Heat The PS4500-P-3S-FC-SUPER is a main controller for Fan coil B.M.S. applications with RS-485 MODBUS Protocol. It has a COOL modular, user-friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it according to customer’s needs on the spot. The PS4500-P-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor or window contact inputs, auto-change-over and smart algorithm for maximum energy saving. The PS4500-P-3S-FC-SUPER is factory pre-programmed to save valued time on field programming. ECONOMY Please note the PS-4500 is also available as a CTU-4500, FAULT INPUT with additional advanced features. Features y Main Input- 220VAC y Various F/C Applications, jumper selectable: * 2-pipe systems * 4-pipe systems * no valve system y 0-10V proportional outputs for Cool & Heat y T1 sensor – Return Air Sensor y T2 sensor – Auto-change over sensor (Mode is set COMM y 3 Speeds output – 220VAC, 3Amp each – with Auto Speed function y Energy Saving – cost efficient, environmental friendly algorithms y Wall or flush mount panels and remote control F y Occupancy sensor – with 12VDC supply built-in ideal for 2-pipe systems) y Temperature reading from panel or main board – Closed, when Open all outputs are OFF C y C° or F° temperature scale display y Condensing Pump output – active only in Cool y Fault input, dry contact, voltage-free – Normally EXT. SENSOR OPTION receivers available based on temperature of the incoming water flow, y T3 sensor – Indoor coil sensor for Heat (soft-start) AUTO CHANGE-OVER DIP switch selectable y Offset for temperature reading – -6° … +6° y Set point limits - 10°…30°C y Fault input – Normally Closed, for indication through protocol www.meitavtec.com | [email protected] 8-13 Communication PS4500-P-3S-FC-SUPER - Modbus RTU Protocol Configurations Main Panel PS4500 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories Wiring diagram Fan (230VAC, 3A) Main input 230VAC N ~ 0 PR Occupancy sensor Y 0 0 F1 0 0 W F2 HEAT 13 0 F3 0 12 11 F4 0 Not in use 8-14 www.meitavtec.com | [email protected] T1 F5 0 0 T2 F6 0 T3 0 Y 0 1 IR -12V +12V 2 3 8 Room panel (option) 7 Not in use P1 P2 A P3 B Communication PS4500-PM-3S-FC-SUPER – Modbus RTU Protocol Main Controller for Fan Coil, Building Management FC System (BMS) applications, with Modbus protocol (RS-485), with Pulse Modulating, proportional B.M.S outputs (floating) for Cool & Heat COMPATIBLE The PS4500-PM-3S-FC-SUPER is a main controller for Fan COMM coil B.M.S. applications with Modbus Protocol. It has a modular, user-friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it HEAT according to customer’s needs on the spot. The PS4500-PM-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor or window contact inputs, auto-change-over and smart algorithm for maximum AUTO FAN energy saving. The PS4500-PM-3S-FC-SUPER is factory pre-programmed to AUTO CHANGE-OVER save valued time on field programming. Please note the PS-4500 is also available as a CTU product ECONOMY with additional advanced features. C Features y Main Input- 220VAC y Main controller for various Fan Coil applications, jumper selectable: * 2-pipe systems * 4-pipe systems * no valve system y Proportional outputs (3-wire) for Cool and Heat valves (open/close time adjustable through protocol) - 24VAC y Auto-change over sensor (Mode is set based on temperature of the incoming water flow, ideal for 2-pipe systems) y Auto-change-over sensor active (for 4-pipe systems) 2 separate outputs for Cool & Heat y Fan Only – jumper selectable y Environmental friendly & economic – with smart algorithm for maximum energy saving 3-WIRE OUTPUT FAULT INPUT y 3 fan speeds - 220VAC, 3Amp each- with Auto Speed function RT03 y Indoor coil sensor for Heat (soft-start) y Wall and flush mount thermostats- option y Fault inputs, dry contact, voltage-free, for occupancy sensor, window contact or fault input - for indication through protocol y °T ambient reading from panel or main board - DIP switch selectable y Auto-Fan or Fan-On – jumper selectable y Occupancy sensor input www.meitavtec.com | [email protected] 8-15 8-16 www.meitavtec.com | [email protected] Communication Modbus protocol Fault 2 (indication through protocol) Enable fan only mode ETN-X500 Fault 1 (open – all outputs off) OR Indoor coil sensor FMH-X500 Change over sensor Return air sensor Low Medium High Common for fan OR Not in use Open Close Common Common Open Close Communication PS4500-PM-3S-FC-SUPER – Modbus RTU Protocol Configurations Main Panel PS4500 OR FMT-X500 IRP-X500 Control Panels/Accessories Wiring diagram Communication PS4500-TA2-3S-FC-SUPER – Modbus RTU Protocol Main Controller for Fan Coil, Building Management System (B.M.S.) applications, with Modbus protocol (RS-485), with proportional outputs for Thermal B.M.S Actuators (230 VAC) COMPATIBLE The PS4500-TA2-3S-FC-SUPER is a main controller for Fan Coil B.M.S. applications with Modbus Protocol. It has a COMM modular, user-friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it according to customer’s needs on the spot. HEAT The PS4500-TA2-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor or window contact inputs, auto-change-over and smart algorithm for maximum energy saving. AUTO FAN The PS4500-TA2-3S-FC-SUPER is factory pre-programmed to save valued time on field programming. AUTO CHANGE-OVER Please note the PS-4500 is also available as a CTU product with additional advanced features. ECONOMY EXT. SENSOR OPTION Features y Main Input- 230VAC y Main Controller for various Fan Coil applications, y 3 Speed output- 220VAC, 3Amp each- with Auto Speed selection function jumper selectable: y Environmental friendly & economic – with * 2-pipe systems smart algorithm for maximum energy saving * 4-pipe systems * no valve system y Proportional output for Thermal Actuators by 230VAC (0.4 Amp.) Open/Close outputs y T1 sensor – Return Air sensor y T2 sensor - Auto-change over sensor - Mode is set y Wall and flush mount thermostats- optional input y Occupancy sensor- Normally Closed, when open for 10 minutes, all outputs off ideal for 2-pipe systems y F° or C° temperature scale y T3 sensor – Indoor Coil sensor for Heat (soft-start) 3-WIRE OUTPUT occupancy sensor, window contact or fault y Pump output – active only in Cool 2 separate outputs for Cool & Heat F y Fault input dry contact, voltage-free, for based on temperature of the incoming water flow, y Auto-change-over logic active (for 4-pipe systems) – C y Fan Only – selectable y Auto-Fan feature - selectable y °T ambient reading from panel or main board – DIP switch selectable www.meitavtec.com | [email protected] 8-17 Communication PS4500-TA2-3S-FC-SUPER – Modbus RTU Protocol Configurations Main Panel PS4500 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories www.meitavtec.com | [email protected] Indoor coil sensor Change over sensor 0 F2 IR -12V +12V 0 0 F3 0 F4 0 F5 1 2 0 F6 3 8 7 A B Communication Modbus protocol Heat Valve F1 T3 Room panel (option) Fault 2 (indication through protocol) 0 0 0 Enable fan only mode Cool Valve W PR T2 Fault 1 (open – all outputs off) 0 0 0 Occupancy sensor Not in use CL1 OP1 COM COM CL2 OP2 T1 Not in use C Not in use R Y Return air sensor 11 PUMP Not in use Low 12 L Not in use 13 N 24VAC input (for valves) 8-18 Medium Main input 230VAC Fan (230VAC, 3A) High Condensing pump (230VAC, 1A) Wiring diagram Communication CTU4500-P-3S-FC-SUPER – Modbus RTU Protocol Main Controller for Fan Coil in Building Management System (B.M.S.) applications, with RS-485 Modbus protocol and proportional (0-10V) outputs for the Fan-Coil valves The CTU4500-P-3S-FC-SUPER is a main controller for Fan coil in B.M.S. applications with Modbus Protocol. It has a modular, user-friendly design with various F/C applications built-in, field selectable. This modularity allows you to have one main controller for different F/C applications and suit it HEAT according to customer’s needs on the spot. 0-10V The CTU4500-P-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor or window contact OUTPUT inputs, auto-change-over and smart algorithm for maximum energy saving. The CTU4500-P-3S-FC-SUPER is factory pre-programmed to save valued time on field programming. C Features y Main Input- 220VAC y Fan Only - selectable y F/C applications, DIP switch selectable: y Energy saving – cost efficient, environmental * 2-pipe systems * 4-pipe systems y Proportional outputs (0-10V or 2-10V) for Cool & Heat valves. y T1 sensor – Return Air Sensor y T2 sensor - Auto-change over sensor (Mode is set based on temperature of the incoming water flow, ideal for 2pipe systems) y T3 sensor - Indoor coil sensor for Heat (soft-start) y Fault (1) input, dry contact, voltage-free - Normally Closed, when open all outputs turn off y Fault (2) input dry contact, voltage-free, for Occupancy Senor y 3 Speeds output- 220VAC, 3Amp each with Auto Speed function friendly algorithms y Occupancy Sensor (12VDC supply) – adjustable 0…3600 sec. AUTO FAN FAULT INPUT y Fan On/Auto-Fan in Cool or Heat – DIP switch selectable y Condensing Pump output -230VAC, 1A (active in Cool) y Offset for temperature reading - -6…+6°C through room panel RT03 y Set point limits - 10°…30°C y Wall & flush mount panels, or IR panel - option y IR input y DIN rail mountable y CE certified www.meitavtec.com | [email protected] 8-19 Communication CTU4500-P-3S-FC-SUPER – Modbus RTU Protocol Configurations Main Panel CTU4500 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories 0 DI2 DI3 8-20 0 www.meitavtec.com | [email protected] 12V 3 T1 7 0 8 T2 Out 0-10V (Cool) Out 0-10V (Heat) Low DI8 12VDC supply voltage – option (30mA max) DI6 DI7 Occupancy sensor 0 Enable fan only mode DI4 DI5 Fault 1 (open – all outputs off) Not in use 0 2 AO1 0 AO2 0 T3 0 A B Communication Modbus protocol DI1 1 X1 DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 Indoor coil sensor V1 Change over sensor L Room panel (option) Return air sensor N Medium Not in use Fan 230VAC, 3A High Main input 230VAC Pump output (230VAC,1A) Wiring diagram Communication CTU4500-PM2-3S-FC-SUPER - Modbus RTU Protocol Main Controller for B.M.S, Fan-Coil applications, with pulse modulating outputs for Cool & Heat valves, with Modbus protocol. The CTU4500-PM2-3S-FC-SUPER is a main controller for Fan Coil applications, suitable for B.M.S. FC (Building Management System), with Modbus protocol. It has a modular, user-friendly design with various Fan Coil applications built-in, field selectable. This modularity allows you to have one main controller for different Fan Coil applications and suit it according to customer’s needs on HEAT the spot. The CTU4500-PM2-3S-FC-SUPER also offers cost efficient capabilities, such as, occupancy sensor and fault inputs 3-WIRE OUTPUT for maximum energy saving. The CTU4500-PM2-3S-FC-SUPER is factory pre-programmed to save valued time for the installers on field programming. AUTO FAN Features y Main Input- 230VAC y F/C Applications - jumper selectable: * 2-pipe system * 4-pipe system y Pulse Modulating outputs (floating / 3-wire) for Cool and Heat valves - 24VAC (opening / closing duration 0…500 sec. - adjustable) y Auto-change-over sensor (Mode is set based on temperature of the incoming water flow, ideal for 2pipe systems) y Wall /flush mount / IR panels - option y Fault input - dry contact, voltage-free, for occupancy sensor y 4 x fault input – for indication through y Occupancy sensor input (12VDC supply) Normally Closed, when Open – all outputs y Occupancy sensor operation – adjustable – 0…60 minutes y Return Air sensor y Offset y Fan On / Auto-Fan in Cool/Heat – DIP switch selectable y Energy saving – cost efficient, environmental friendly controller ECONOMY are off y Set point limits - 10°…30°C y Auto Fan – option EXT. SENSOR OPTION protocol y Indoor coil sensor input for Heat (soft-start) y 3 Speed output- 230VAC, 3Amp + Auto Speed feature AUTO CHANGE-OVER for temperature RT03 reading – -6…+6°C through room panel y Dead Zone – 0…5°C y IR input y DIN rail mountable y CE certified www.meitavtec.com | [email protected] 8-21 Communication CTU4500-PM2-3S-FC-SUPER - Modbus RTU Protocol Configurations Main Panel CTU4500 OR OR OR IRP-X500 ETN-X500 FMH-X500 FMT-X500 Control Panels/Accessories www.meitavtec.com | [email protected] Close 1 T1 0 T2 0 T3 0 2 A 3 B Communication Modbus protocol 12V Indoor coil sensor DI8 Open Common 0 Change over sensor DI6 DI7 Return air sensor 0 Room panel (option) PO1 COM PO2 PO3 COM PO4 12VDC supply voltage – option (30mA max) DI4 DI5 Close Common Open (24VAC, 2.5VA) High (24VAC, 2.5VA) Occupancy sensor 0 Fault 2 DI2 DI3 Fan 0 Fault 1 DI1 Cool Valve X1 DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 Fault 5 V1 Fault 4 L Fault 3 N Not in use 8-22 Not in use Heat Valve Low Main input 230VAC Fan 230VAC, 3A Medium Wiring diagram 7 8 Communication FMHC220-FC-MDB03 - Modbus RTU Protocol Flush mount, 230VAC thermostat, for Fan Coil FC B.M.S. applications, with Modbus protocol B.M.S The FMHC220-FC-MDB03 is a highly versatile, stand alone COMPATIBLE thermostat, suitable for Building Management System application, with Modbus communication protocol – COMM compatible with Modbus application Protocol specification V1.1b (by Modbus IDA-org). With multiple, selectable COOL modes of operation, the FMHC220-FC-MDB03 offers suitability to 2-Pipe, 4-Pipe or HEAT no valve Fan Coil system, electrical heating element option, and can function as either Coo/Heat or Cool Only thermostat. Using DIP switch, technician can select between applying Auto-Change-Over sensor or alternatively utilizing a contact input for Economy mode to save energy. In addition, it offers the Auto-Fan feature to work at either Cool, or Heat or at both. ECONOMY C Overall, the FMHC220-FC-MDB03 offers numerous options, nonetheless setting is simple and user friendly. AUTO CHANGE-OVER Features y Contact input changes to Economy mode or y Flush mount, 230VAC thermostat AUTO FAN turns unit off (Optional) y 2 separate outputs for Cool & Heat y Cool Only thermostat – option y DIP switch selectable options: y Electrical heater - option * Auto-Change-Over sensor or Contact input y Disable Fan operation – option (only in Cool, * 2-pipe or 4-pipe system only in Heat, or in both) * 1 or 3 fan speed control + Auto Speed y Set point limits – 10…30°C * With or without Auto-Change-Over mode y 3 Auto-Fan types: * Auto-fan in Cool & Heat * Set point & room temp. display on LCD, or set point temp. display only * Auto-fan only in Cool * Always Auto-fan or Auto-fan selectable * Auto-fan only in Heat * Internal or external temperature sensor y Password for protected setting y Modes: Cool/ Heat / Auto- Change-Over/ Fan Only y Pushbutton beeper – option y Hand held remote control (RT03) - option Wiring diagram Indoor Fan (230VAC, 1.5A) Heat valve / Heat element (230VAC, 1A) Main Input 230VAC Cool valve (230VAC, 1A) A Communication (Modbus) B RE HE 3 2 1 ~ N High voltage wires T2 Contact input (remote switch) or Auto-change over sensor 0 External sensor (option) T1 www.meitavtec.com | [email protected] 8-23 Communication ETN-X500 Wall mount, thermostat panel, serving as a user interface of applicable for a communicating B.M.S (Building controller, Management Systems) The ETN-X500 is a wall mount, thermostat panel, FC functioning as a user interface of a communicating controller. Having advanced communication capabilities, it is an ideal panel for B.M.S. applications. Temperature may be sensed either through the wall panel’s built-in temperature sensor, or through the return air sensor connected to the main board. HEAT The ETN-X500 is a well designed room panel for Meitav-tec's communicating controllers, appreciated by architects worldwide. AUTO FAN Features y Wall mount panel through the wall panel’s built-in y Built-in communication temperature sensor, or through the y On /Off return air sensor – DIP switch y Set temperature y Modes: Cool / Heat / Auto-Change-Over/Fan Only y Auto-Fan y 3 fan speeds Wiring diagram 8-24 y Temperature may be sensed either www.meitavtec.com | [email protected] selectable y Suitable for Meitav'tec's controllers y Silicon rubber pushbuttons y Large, easy to read display y Various panel colors available RT03 Communication FMH-X500 Flush mount, thermostat panel, serving as a user interface of Meitav-tec communicating controller, applicable for B.M.S (Building Management Systems) The FMH-X500 is a flush mount, thermostat panel, functioning as a user interface of a communicating controller. FC Having advanced communication capabilities, it is an ideal panel for BMS applications. Temperature may be sensed either through the wall panel’s built-in temperature sensor or through the return air sensor connected to the main board. HEAT The FMH-X500 is a smart looking thermostat with a soft 1/3 aesthetic shape and a large, easy to read LCD display SPEEDS Features AUTO FAN y Flush mount, horizontally shaped panel y Built-in communication y On /Off y Set temperature y Modes: Cool / Heat / Auto-Change-Over/Fan Only y Temperature may be sensed either through the wall panel’s built-in temperature sensor, or through the return air sensor – DIP switch selectable y Suitable for Meitav'tec's B.M.S. communicating controllers y Auto-Fan y Silicon rubber pushbuttons y 1 or 3 fan speeds y Large, easy to read display EXT. SENSOR OPTION C F y Various panel colors Wiring diagram www.meitavtec.com | [email protected] 8-25 Communication FMT-X500 Flush mount, thermostat panel, serving as a AC user interface of a communicating controller, applicable for B.M.S (Building Management Systems) COOL The FMT-X500 is a flush mount, thermostat panel, functioning as a user interface of a communicating controller. Having advanced communication capabilities, it is an ideal panel for BMS applications. Temperature may be sensed either through the wall C F panel’s built-in temperature sensor, or through the return air sensor connected to the main board. COMM Features y Flush mount, vertically shaped, panel y Built-in communication y On /Off the wall panel’s built-in temperature sensor, or through the return air sensor – DIP switch selectable y Set temperature y Suitable for Meitav'tec's controllers y Modes: Cool / Heat / Auto-Change-Over/ y Silicon rubber pushbuttons Fan Only y Auto-Fan y 3 fan speeds Wiring diagram 8-26 y Temperature may be sensed either through www.meitavtec.com | [email protected] y Large, easy to read display y Various panel colors RT03 Communication IRP-X500 + RT03 Infra Red Panel operating +IR remote Control to operate Meitav-tec's communicating controller, applicable for B.M.S. (Building Management AC Systems) The IRP-X500 is an Infra Red Receiving Panel operating a FC communicating controller. Having advanced communication capabilities, it is a perfect solution for B.M.S. applications. Temperature may be sensed either through IRP's built-in temperature sensor, or through the return air sensor connected to the main board. HEAT Features y Wall mount, Infra Red Panel + IR remote control y Built-in communication with controller y On /Off y Temperature through the may wall be sensed panel’s either built-in temperature sensor, or through the return air sensor – jumper selectable y Set temperature y Suitable for Meitav'tec's controllers y Modes: Cool / Heat / Auto-Change-Over/Fan Only y Panel dimensions – 46 x 38 x 19 mm RT03 y Auto-Fan y 1 or 3 fan speeds Wiring diagram www.meitavtec.com | [email protected] 8-27 Communication FMHC220-P-FC-MDB01 – Modbus RTU Protocol Flush mount, 230VAC thermostat, for Fan Coil B.M.S. applications, with proportional outputs for Cool & Heat, 3 Fan Speeds and B.M.S Modbus interface COMPATIBLE The FMHC220-P-FC-MDB01 is a distinguished, stand alone, proportional thermostat for 2-Pipe or 4-Pipe Fan Coil applications. Its Modbus communication protocol makes it also compatible for Building Management System COOL (B.M.S.) applications. HEAT It offers modular, user friendly configuration to best suit customer’s needs. Features, such as Set Point limits, dead zone or offset are adjustable while others as internal / external sensor 1 or 3 fan speed or auto-change-over are all selectable. The FMHC220-P-FC-MDB01 is an esthetic, flush-mount thermostat which offers increased energy savings as well as comfort to the user. SPEEDS Features y Internal /External sensor y 2 proportional (0-10V) outputs for Cool & Heat y Energy Only y DIP switch selectable options: saving – cost efficient, environmental friendly thermostat y Dead zone – 0…5°C y Offset - ±6°C * 1 or 3 fan speed y Lock / un-lock thermostat pushbuttons * Auto-change-over sensor or Contact input y Pushbutton beeper - option * With or without auto-change-over y Programmable MAC address – 1…99 temp. display only y Auto-Fan Wiring diagram www.meitavtec.com | [email protected] ECONOMY C y Set point temp. limits – 10…30°C * 2Pipe or 4Pipe Fan Coil * Set point & room temp. display or set-point 8-28 AUTO CHANGE-OVER y Flush mount, 230VAC thermostat y Modes: Cool/ Heat / Auto- Change-Over/ Fan 1/3 addresses – DIP switch configurable EXT. SENSOR OPTION LOCK OPT. y Fits into Gewiss box y Remote control (RT03) - optional RT03 Communication PS4500-AC-SUPER-02-WET – Modbus RTU Protocol Main Controller for A/C in Building Management B.M.S System (BMS) application, with Modbus protocol COMPATIBLE The PS4500-AC-SUPER-02 is a main controller, with COMM Modbus Protocol, for A/C Modbus BMS applications. It AC has a modular, user-friendly design with various A/C applications built-in, field selectable. This modularity allows you to have one main controller for different A/C applications and suit it according to customer’s needs COOL on the spot. The PS4500-AC-SUPER-02 also offers cost efficient HEAT capabilities, such as, occupancy sensor, cooling stages and smart algorithm for maximum energy saving. The PS4500-AC-SUPER is factory pre-programmed to save valued time on field programming. Please note the PS-4500 is also available as a CTU-4500, with additional advanced features. HP/HC Features y Main controller for multi AC applications y Occupancy Sensor input- 12VDC supply y Main Input- 230VAC * Normally Closed input, Active when open y Outputs may be 230VAC or any other according to * Work options – Off / Economy Set point the phase input (WET terminology) y User Selectable applications: * Heat/Cool or Heat Pump (HC/HP) * Turn Off all outputs when open y Flow Sensor input – (F3) * Normally Closed input, Active when open * Heat Pump in Heat or Heat Pump in Cool * When open, compressor & heating outputs y 3.5 minute delay for compressor - Jumper selectable y 1 or 3 fan speed control - Jumper selectable y 3 x Temperature sensor inputs: * T1 sensor - Return Air sensor * T2 sensor - Outdoor sensor for Deicing in heat mode, or Overheat protection in cool mode * T3 sensor - Indoor sensor for Deicing in cool mode, or Overheat protection in heat mode y 3 x Fault input, dry contact, voltage-free, Normally Closed: COMPRESSOR DELAY y Window Contact input – (F2) * Electric Heat or Oil/Gas y Up to 3 stages of Heat and 2 stages of Cool AUTO CHANGE-OVER ECONOMY EXT. SENSOR OPTION FAULT INPUT turn off y Celsius or Fahrenheit temperature display y Ambient Temperature reading from panel or C F from main board - selectable y Wall or flush mount panels available RT03 y Lock pushbuttons - option y Offset for temperature reading – through room panel y Set point limits - 10°…30°C , 50…86 oF y Dead Zone, adjustable - 0…5°C , 0…12 oF y Offset - ±6°C adjustable * Fault 1 – for indication through protocol * Fault 2 - for Window contact (N.C.) * Fault 3 – for Flow sensor www.meitavtec.com | [email protected] 8-29 Communication PS4500-AC-SUPER-02-WET – Modbus RTU Protocol Configurations Main Panel PS4500 OR TS-01 sensors only (no panel) OR IRP-X500-02 OR FMH-X500-02 Control Panels/Accessories Wiring diagram 8-30 www.meitavtec.com | [email protected] ETN-X500-02 Communication CTU2601 - BACnet Protocol Input / Output card for BACnet communication net The CTU-2601 is an Input / Output (I/O) card for BACnet communication net, designed to control various devices from software. 0-10V OUTPUT It has 8 inputs, dry contact to view the status of any EXT. SENSOR OPTION device or other input connected and 8 outputs to control any device, such as: - Air compressor - Chiller - Fresh air damper - Lights - Pump - Fans The CTU-2601 also offers 3 Temperature sensor inputs in order to view temperature in different locations, 2 Analog Inputs and 2 Analog Outputs. Features y 8 Digital Outputs – Available in either 230VAC, 110VAC y 3 Temperature reading Inputs* or 24VAC (50KΩ @ 25ºC) y 2 Analog Outputs, 0-10VDC y Easy connection to Din Rail y 8 Digital Inputs – voltage free – dry contact y MAC Address selection by DIP Switches y 2 Analog Inputs, 0-10VDC * The 3 Temperature readings inputs may be used as Digital Inputs – Dry contact as well. T1 0 T2 0 Temp. sensor T2/ Digital Input 10 DI8 Temp. sensor T1 / Digital Input 9 0 Digital Input 8 Digital Input 7 DI6 DI7 Digital Input 6 0 Digital Input 5 DI4 DI5 Digital Input 4 Digital Input 3 0 Analog Output 2 0 AI1 0 AI2 5VDC A Communication BACnet protocol DI2 DI3 Analog Input 2 0 0-10VDC DI1 AO1 0 AO2 X1 DO1 DO2 DO3 DO4 DO5 DO6 DO7 DO8 Analog Input 1 V1 Digital Input 2 L Digital Input 1 N 0-10VDC Digital Outputs 1-8 230VAC, 0.5A each Temp. sensor T3 / Digital Input 11 Main input 230VAC Analog Output 1 Wiring diagram T3 B Normally Open www.meitavtec.com | [email protected] 8-31 Communication CTU4601 - Modbus RTU Protocol Input / Output card for Modbus communication net The CTU-4601 is an Input / Output (I/O) card for Modbus communication net, designed to control various devices from B.M.S. software. EXT. SENSOR OPTION It has 8 inputs, dry contact to view the status of any device or other input connected and 8 outputs to control any device, such as: - Air compressor - Lights - Chiller - Pump - Fresh air damper - Outdoor Lights The CTU-4601 also offers 3 Temperature sensor inputs in order to view temperature in different locations and 2 analog inputs. Features y 8 Digital Outputs – Available in either y 3 Temperature reading Inputs (50KΩ @ 25ºC) y Easy connection to Din Rail 230VAC, 110VAC or 24VAC y 8 Digital Inputs – voltage free – dry contact y MAC Address selection by DIP Switches y 2 Analog Inputs, 0-10VDC 8-32 www.meitavtec.com | [email protected] Communication Modbus protocol Analog Input 2 0-10VDC Analog Input 1 Temp. sensor T3 Temp. sensor T2 Temp. sensor T1 Digital Input 8 Digital Input 7 Digital Input 6 Digital Input 5 Digital Input 4 Digital Input 3 Digital Input 2 Digital Input 1 Wiring diagram Multi-Zone Systems PSMZ-100/200 for Multi-Zone System 24VAC, Controller for multi-zone system AC controlling 4 to 7 zones The PS-MZ 100/200 is ideal for residential, commercial or industrial applications. It is compatible with Heat/Cool or Heat Pump HVAC applications and can control up to 4 HEAT (PS-MZ100) or 7 (PS-MZ200) different zones. C F One of the zones serves also as the master, and different types of thermostats can be selected as masters or zones. HP/HC Zones can also be programmed for on/off, ideal for times when the zone is less occupied. The main board offers inputs for Bypass and Fresh Air dampers and 3 different temperature sensors. Other features such as Auto-Changeover mode and quick connectors from the thermostats to the main board, make this multi-zone the simplest and most efficient climate control system. Features PROG y Main Input - 24VAC y Energy saving and cost efficient system y Controls up to 4 zones (PS-MZ100) or 7 zones y Output for dampers- 3-wire , 24 VAC (PS-MZ200) y Fresh Air Dampers- 2 logics for open/close: y Zone 1 also serves as Master (same thermostat) 1. by timer (min per hour), or y Heat/Cool or Heat pump - Selectable 2. by temperature difference (T1-T2) y Up to 4 stages for Heat and 2 stages for Cool y Selectable Heat output- Electric or Oil/Gas (jumper selectable) y Modes: Cool, Heat, Auto-change Over, Fan Only – selectable through Master only y T1 Sensor - Indoor temperature sensor- option (for Fresh Air Damper) y T2 Sensor - Outdoor temperature sensor- option (for Fresh Air Damper) EXT. SENSOR OPTION y Bypass Damper (3-wire) output y Display temperature available in °C or °F – depending on model ordered y Economy mode (Unoccupied mode) – optional y Zone thermostats with weekly program – optional, depending on model ordered y Weekly Program type- (5-1-1) - 4 times Set Cool/Set Heat y T3 Sensor - Indoor Coil sensor (freeze protection in Cool and overheat protection in Heat) www.meitavtec.com | [email protected] 9-1 Multi-Zone Systems PSMZ-100/200 for Multi-Zone System Master & Zone 1 M100 Different types of thermostats can be selected for masters and zones; wall or flush mount, with C° or F° temperature display, programmable or non-programmable. Programmable controllers are ideal for times when zones are unoccupied, and is therefore energy saving and cost efficient. When thermostat functions as a Master, it Controls main system functions: Functions of thermostat as Zone 1: y Local Fan y On/Off y Local set point y Mode (Cool, Heat, Auto, Fan Only) y Weekly program- option depending on y Activate or de-activate Economy Mode - Unoccupied thermostat ordered Mode) y Set Fresh Air damper logic Zone Z100 y Set local On/Off status y Weekly program- option (depending on thermostat ordered) y Set local set point y Fan On / Auto Fan Models Master & Zone model Scale Program. Zone Model Scale Program. ETN-M100-C Celsius - ETN-Z100-F Fahrenheit - ETN-M100-F Fahrenheit - ETN-Z100-C Celsius - ETN-M100-Prog-C Celsius + ETN-Z100-F-Prog Fahrenheit + ETN-M100-Prog-F Fahrenheit + ETN-Z100-C-Prog Celsius + Note: All Master and Zone thermostats are available in flush-mount models (FMT) as well. Wiring diagram 9-2 www.meitavtec.com | [email protected] Multi-Zone Systems PS 2007/P - Multi-Zone Control System 230VAC system Controller with for multi-zone proportional, A/C SYSTEM 3-wire Master M2007/E PS-2007/P damper outputs, to control up to 7 AC DAMPER CONTROL zones COOL The PS 2007/P is a simple yet extremely intelligent controller for Multi-Zone system, ByPass Damper ideal for small to medium scale apartments HEAT Upto 7 Zone Dampers and houses. HP/HC Upto 7 Zone Thermostats 3-WIRE OUTPUT Controlling up to 7 zones, it is compatible with Heat/Cool or Heat Pump HVAC systems. The PS 2007/P offers proportional damper outputs (both for the zones and the bypass and 3 different temperature sensor inputs. With C a separate master to control the system parameters (ON/OFF, Mode, Fan), the PS 2007/P is an environmental EXT. SENSOR OPTION friendly and energy saving system. Features y Main Input - 230VAC y Controls up to 7 zones y 3 wire, proportional damper output y Selectable system configuration- Heat/Cool or Heat Pump y Selectable Heat output- Electric or Oil/Gas (jumper selectable) y Up to 3 stages of Heat and 2 stages of Cool y Modes: Cool, Heat, Fan Only- selectable through Master only y T2 - Outdoor coil temperature sensor (de-frost RT41 y T3 - Indoor coil temperature sensor (freeze protection in Cool) y Energy saving, environmental friendly system TIMER ECONOMY y Wall or flush mount thermostat for zone controller (ETN-41-P or FMH-41-P) PROG y Master unit with weekly program- start time/stop time y Zone damper outputs- Proportional Integral logic (for Meitav-tec dampers only) y Bypass damper output - proportional y Open / Close time 13-15 seconds, I=20mA protection in Heat) www.meitavtec.com | [email protected] 9-3 Multi-Zone Systems PS 2007 - Multi-Zone Control System M2007 Master Controller Wall mount, Master Controller for Multi-zone systems (up to 7 zones) The M2007-E Master Controller is the main controller for the main system functions. Features y On/Off y Fan speed (Hi-Med-Low) y Modes: Cool, Heat, Fan Only y Fan On – Auto Fan y Set weekly program for all system - optional y Energy saving and cost efficient Zone Z-2007 Zone Controller for Multi-zone systems Wall or flush mount with optional hand held remote control Two types of controllers can be selected for zones; y Wall-mount - ETN-41-P-IR, with hand held remote control (RT-41) y Flush-mount - FMH-41-P-IR, with hand held remote control (RT-41) Features y Set local On/Off status y Set local temperature set point 9-4 www.meitavtec.com | [email protected] Multi-Zone Systems PS-MZ502 Multi-Zone System 24VAC, Multi-Zone and climate control system, to AC control up to 31 zones FC The PS-MZ502 is an advanced multi-zone system controlling up to 31 Zones. It is the perfect climate control system for small to medium residential, commercial or COOL industrial applications, enabling users to decide which rooms in their house or office will be air conditioned or HEAT closed. Suitable for Heat/Cool or Heat Pump applications, the HP/HC PS-MZ502 allows multiple stages of Cool and Heat. 1/3 The Master Unit M500 allows users to view and change SPEEDS zone parameters, such as local On/Off and set point. It is also used to set the main system parameters. FAULT INPUT Through the main board, features such as proportional Fresh Air and Bypass damper outputs are available. A special pressure sensor input exists, in order to control the bypass damper. There are also 2 different fault inputs and 3 C F temperature sensor inputs. Overall, the PS-MZ502 multi-zone system improves occupant comfort with maximum energy saving. EXT. SENSOR OPTION Features y Main Input - 24VAC y T1- Indoor temperature sensor y Controls up to 31 zones y T2- Outdoor temperature sensor y Energy saving, environmental friendly system y T3- Duct temperature sensor (freeze protection in y Communication to Maxinet Thermostat network y Selectable system configuration- Heat/Cool or Heat Pump, 2 Pipe or 4 Pipe Fan Coil y Display temperature available in C° or F° y 12-h Timer / 24-h Timer – DIP switch selectable y Access zones from master (set point, on/off) y Selectable Heat output- Electric or Oil/Gas (jumper y Master unit with weekly program- jumper selectable y Modes: Cool, Heat, Auto-change Over, Fan Onlyselectable through Master ONLY y Output for dampers- 3-wire, 24VAC, general purpose with P.I logic * Zone dampers- open / close time adjustable * Fresh Air Dampers- 2 logics for open/close: o by timer (min. per hour) OR o by temperature difference (T1-T2) * Bypass Damper (0-10V) output- 2 options: o by pressure (input for air pressure sensor) OR ECONOMY Cool, overheat protection in Heat) y Up to 4 stages of Heat and 2 stages of Cool selectable) AUTO CHANGE-OVER TIMER y Weekly Program- 7 days, 4 programs per day (start time/stop time) y 1 or 2 fan speeds y Input for air pressure sensor- for bypass output y Compressor delay- option y Economy (Set Back) Mode available for individual zones or all the system y F1- Fault input, normally closed, voltage free- all system OFF y F2 - Fault input, normally closed, voltage freealarm indication on master o by number of rooms www.meitavtec.com | [email protected] 9-5 Multi-Zone Systems PS-MZ502 Multi-Zone System Master M500 Controller Zone Z500 Controller The Master M500 of PS-MZ502 Multi Zone system The Zone Z500 controls the following functions: controls main system and zone functions : y Set local On/Off status Main system functions y Set local set point y On/Off y Modes: Cool, Heat, Auto-change-over, Fan Only y Fan: Fan On – Auto Fan y Activate or de-activate Economy Mode (Unoccupied Mode) y View main system parameters- damper status, faults, pressure, T2, T3 y Set Fresh Air damper and Bypass damper logic y Set weekly program for all system- option (7 days, 4 programs per day) y Maxinet Networking connection - option Zone Functions y local ON/OFF y Set point y Local temperature limits - password protected y View zone parameters- mode, set point, % open of dampers Wiring Diagram 9-6 www.meitavtec.com | [email protected] y Set local temperature limits (password protected) y Adjust damper’s open/close time Damper Control Solutions ETN-24-AZC 24VAC damper controller, proportional, with an DAMPER CONTROL option for a duct temperature sensor COOL The ETN-24-AZC is the best stand-alone damper controller with a proportional output. This thermostat can control all HEAT standard, general purpose dampers- (3-wire, 24VAC) and its Open / Close time is adjustable by the user. AUTO CHANGE-OVER The ETN-24-AZC also has a special option to connect a duct ECONOMY temperature sensor, which senses the airflow temperature and automatically selects the mode (Auto-Change-Over). C Features F y 24VAC damper controller y Set point limits for cooling and heating y Proportional, 3-wire output for dampers y Adjustable open/close time for motor y Two different temperature scales: Fahrenheit or Celsius y External Sensor – Option y Offset for temperature reading adjustment y Energy saving – cost efficient, environmental friendly EXT. SENSOR OPTION (10 - 400 seconds) y Duct sensor for Auto Change-Over mode – option y Remote Control – RT41 thermostat Wiring diagram www.meitavtec.com | [email protected] 10-1 Damper Control Solutions FMT-24-AZC-Proportional-IR Flush mount, 24VAC thermostat for Damper control, with a proportional 3-wire output The FMT-24-AZC is an ideal stand-alone damper COOL controller with a proportional floating output. This thermostat can control all standard, general purpose HEAT dampers- (3-wire, 24VAC), and its Open / Close time is adjustable by the user. AUTO CHANGE-OVER The FMT-24-AZC has also a special option to ECONOMY connect a duct temperature sensor, which senses the airflow temperature and automatically selects the mode (Auto-Change-Over). 3-WIRE OUTPUT C Features y Flush mount, 24VAC thermostat y Proportional output for dampers – 24VAC, 3-wire y Two temperature scales: Fahrenheit or Celsius y Offset for temperature reading adjustment y Duct sensor for Auto Change-Over mode – optional Wiring diagram 10-2 www.meitavtec.com | [email protected] y Energy saving – cost efficient, Environmental Friendly implemented logic y Set point limits for cooling and heating y Adjustable open/close time for motor (10-400 seconds) y IR Remote Control F EXT. SENSOR OPTION Damper Control Solutions ETN-40P1 Wall mount, room thermostat, with IR-option for DAMPER CONTROL damper control, On/Off to Damper COOL The ETN-40P1 is a wall mount, thermostat panel, functioning as a user interface for damper control. HEAT The ETN-40P1 is a smart looking thermostat with a soft C aesthetic shape and a large, easy to read LCD display Features AUTO CHANGE-OVER Wiring diagram EXT. SENSOR OPTION y Wall mount, 12V thermostat y Control of: RT03 * On /Off - 12V signal to damper * Set temperature y Remote control (RT40) – optional 0 T M- M+ 8 7 y External Temp. sensor – optional y Silicon rubber pushbuttons y Large, easy to read display y Various panel colors y Works with DA-401 dampers family www.meitavtec.com | [email protected] 10-3 Damper Control Solutions FMH-40P1 Flush mount, room thermostat, with IRoption for damper control, On/Off to Damper The FMH-40P1 is a flush mount, thermostat panel, COOL functioning as a user interface for damper control. The FMH-40P1 is a smart looking thermostat with HEAT a soft aesthetic shape and a large, easy to read C LCD display Features y Wall mount, horizontally shaped, 12V thermostat Wiring diagram y Control of: * On /Off – open/close the damper * Set temperature y Timer y Remote control (RT40) - optional y Silicon rubber pushbuttons y Large, easy to read display y Various panel colors y Works with DA-401 dampers family IRP-401 Infra red receiver panel + IR remote Control for damper control, On/Off to Damper DAMPER CONTROL The IRP-401 is an Infra Red Receiving Panel for damper control. 12V operation and power to Damper. C Features y Control of: * On /Off * Set temperature y Suitable for Meitav-tec's dampers - DA-401 dampers family y Dimensions – 46 x 38 x 19 mm 10-4 www.meitavtec.com | [email protected] RT03 Dampers DA-401 - Stand Alone Dampers VAV Stand-alone dampers for air flow capacity regulation and control. Available in 6",8" & 10" diameter DAMPER CONTROL The Stand Alone proportional dampers are the best way to obtain optimum results from today's air conditioning ducting systems. They allow you to have complete control over which rooms at home are air-conditioned or closed, and are HEAT thus energy saving. Dampers can be operated by two different control devices: RT40 room thermostats, or by IR receiver with hand held remote control. Users decide on mode and set point and the damper will open or close accordingly. DA-401 dampers are available in 6”, 8” & 10” diameter. Features y Main supply - 12VAC y Two different control options: y Stand alone proportional damper * Room thermostat y Energy saving & environmentally friendly * Infra Red Receiver + Hand held remote control Models Model Diameter DA6"-401 6" DA8"-401 8" DA10"-401 10" Main input 230VAC 0 ~ PS201P Wiring diagram 7 8 7 8 Main input 230VAC 0 IR Receiver ~ 12VDC Room thermostat PS201P 7 8 R - + B M- M+ TJ J2 12VDC Damper motor Application 1 – IR Receiver + Remote contrrol TJ J2 12VDC M- M+ Damper motor Application 2 – Room thermostat www.meitavtec.com | [email protected] 10-5 Dampers DA-24-3W Stand alone damper – DAMPER CONTROL Air flow regulator & control 3-WIRE OUTPUT Available in 6”, 8”, 10” diameter Damper for climate control are the best way to regulate airflow in a multi-zoned house, hotel or office building to improve efficiency and occupant comfort. Dampers allow you to have complete control over which rooms are air conditioned or closed, and are thus energy saving. Users decide on mode and set point and the damper will open or close accordingly. Dampers are available in 6”, 8” & 10” diameter. Features y Main supply - 24V y Damper control - via room thermostat y Energy saving & environmental friendly y Stand alone, proportional damper y Available in 6”, 8” and 10” diameter y Proportional, 3 wire open /close y Damper opening/ closing duration: 8 seconds Note: These dampers are available also with a Temperature Sensor (DA-24-3W-T series) Open Close Common COM OP CL COM DA-24-3W 10-6 Temperature sensor Common CL Open Close Wiring diagram OP T DA-24-3W-T www.meitavtec.com | [email protected] T Floor Heating FE-340-H1 Wall mount, 230VAC thermostat for Floor Heating The FE-340-H1 thermostat for floor heating elements perfectly suits commercial and residential applications. The FE-340-H1 thermostat has been specifically designed C for Floor Heating systems and has an output for Heat only (16Amp). EXT. SENSOR OPTION The FE-340-H1 is attractively designed, easy to use and is energy saving solution for Floor Heating applications. Features y Main Supply - 230VAC y Range - 10-30°C y Output for Heat Element only- 230VAC, 16Amp y External Sensor- option (TS05 or TS06) y Offset – for temperature reading adjustment y Energy saving – cost efficient, environmental friendly thermostat y Large, easy to read display y Soft, silicon pushbuttons y Neutral, aesthetic color y Fits into Standard Gewiss Box (GW24 203) Wiring diagram www.meitavtec.com | [email protected] 11-1 Floor Heating FE-340-H1-PAR Wall mount, 230VAC thermostat, for Floor Heating applications, with Overheat protection (27°C) The FE-340-H1-PAR thermostat for floor heating is C perfectly suitable for higher-end commercial or residential applications. EXT. SENSOR OPTION The FE-340-H1-PAR-45 thermostat, with an output for Heat only (16Amp), has been specifically designed for Floor Heating, parquet systems, TIMER where temperature mustn't exceed 27°C (Adjustable). RT41 The FE-340-H1-PAR, with its over heat protection is a simple, yet convenient solution for floor heating systems. Features y Main Supply - 230VAC y Output for Heat Element only- 230VAC, 16Amp y Special Floor Temperature Sensor input (T-TO) for overheat protection y Overheat Protection- Heat output turns off if temp. reaches 27°C y Energy saving – cost efficient, environmental friendly thermostat y Offset – for temperature reading adjustment y IR remote control – option y Timer operation (By Remote control) y Fits into Standard Gewiss Box (GW24 203) Wiring diagram 11-2 www.meitavtec.com | [email protected] Floor Heating FE-340-H1-PAR-45 Wall mount, 230VAC thermostat, for Floor Heating applications, with Overheat protection The FE-340-H1-PAR-45 thermostat for Floor Heating is perfectly suitable for higher-end commercial or residential C applications. The FE-340-H1-PAR-45 thermostat has an output for Heat EXT. SENSOR OPTION only (16Amp) and has been specifically designed for Floor Heating, parquet systems, where temperature cannot be allowed to exceed 45°C. TIMER The FE-340-H1-PAR-45, with its over heat protection is a simple, yet convenient and safe solution for floor heating RT41 systems. Features y Main Supply - 230VAC y Output for Heat Element only- 230VAC, 16Amp y Special Floor Temperature Sensor input (T-TO) for overheat protection y Overheat Protection- HEAT output turns OFF if temp reaches 45°C y Energy saving – cost efficient, environmental friendly thermostat y Offset – for temperature reading adjustment y IR remote control – option y Timer operation (By Remote control) y Fits into Standard Gewiss Box (GW24 203) Wiring diagram www.meitavtec.com | [email protected] 11-3 Floor Heating FHV-H1-PR-IR Wall mount, 230VAC thermostat, for Floor Heating applications, with weekly programming The FHV-H1-PR-IR thermostat for floor heating is perfectly residential suitable for applications commercial and has C or been EXT. SENSOR OPTION specifically designed for Floor Heating systems. With weekly programming and external sensor option, the FHV-H1-PR-IR is a simple, yet PROG efficient solution for floor heating systems. TIMER Features y Main Supply - 230VAC y Flush-mount thermostat y Output for Heat element- 230VAC, 13Amp y DIP switch selectable display – Tambient and Tset or Tset only Wiring diagram 11-4 www.meitavtec.com | [email protected] y Energy saving – cost efficient, Environmental Friendly algorithms y IR remote control – option y Weekly program (5-1-1) y Offset – for temperature reading adjustment Floor Heating PS8-FH + ETN-8H Multi Zone Controller (PS8-FH) + Wall-mount Thermostat (ETN-8H) for Floor Heating applications The PS8-FH + ETN-8H multi-zone controller for Floor Heating elements perfectly suits commercial or residential C applications. This multi-zone system consists of one main board to control up to 8 zones and a thermostat. Each zone works ECONOMY with two temperature sensors; ambient temperature sensor and floor temperature sensor for floor overheat protection. The user controls the zones via a wall panel, where each zone may be individually accessed. The PS8-FH + ETN-8H with overheat protection feature is ideal for parquet floors due to its overheat protection logic. Features y Main Supply - 230VAC y Output for up to 8 Heat elements- 230VAC, 1Amp y ETN-8H- wall-mount thermostat control panel (12VDC) for up to 8 zones (output from main board) y Output for up to 8 external temperature sensors (RS01) for ambient temperature (10°-30°C) y Output for up to 8 temperature sensors (TS01) for floor temperature limit y Overheat protection- unit turns off, if floor temperature limit is reached y Floor temperature limit - DIP switch selectable (27°C, 28°C, 29°C or 30°C) y Energy saving, environmental friendly system Wiring diagram www.meitavtec.com | [email protected] 11-5 11-6 www.meitavtec.com | [email protected] Air Quality GAQ - Air Quality Controller & Sensor Series Air Quality controller – wall mount, 24VAC, or 12VDC+PS + Duct / Room sensor GAQ -12/24 24VAC or 12VDC The GAQ series are Air Quality Sensors and Controllers that automatically react to air pollution sources. They sense tobacco smoke, toilet odors, strong kitchen smells, etc. and GAQ Room Sensor mechanically regulate ventilated areas such as cinemas, pubs, restaurants, toilets or conference rooms. The sensor switches the fan on when air quality drops below a preset, adjustable level. The sensing head of the unit is self - cleaning, a process which occurs each time the GAQ Duct Sensor unit is triggered. When atmosphere has returned to normal, the fan switches off. Features Wall mount, Air Quality Controllers Room or Duct air quality sensors y Main supply - 24VAC or 12VDC (with PS) y Main supply - 24VAC or 10-30VDC y The controller has 2 outputs: y Sensor has proportional pre-defined output * Proportional output 0-10VDC for variable fan speed 0-10VDC or B.M.S. applications. * Dry contact for direct fan switching (on/off) or alarm indication y Set point for Air Quality - adjustable y Indication lights to show status of Air Quality controller (On/Off) y Self cleaning sensor OUTPUT 0...10V 10...30VDC 24VAC Wiring diagram www.meitavtec.com | [email protected] 12-1 Air Quality CO Detector Sensor for measuring carbon monoxide (CO) concentration SensiCO PX 300 is a reliable sensor for measuring carbon monoxide (CO) concentration in locations, such as car parks and garages. As CO, a dangerous poisonous gas, has no smell, taste or color, it is important to install SensiCO PX300, as a total protection from CO poisoning. When CO concentration exceeds 50 PPM, a signal to the ventilation system is activated and an alarm is sent to the car park management/ control. SensiCO PX 300 may be connected to a self-control system or to the B.M.S. (Building Management System), using its analog output. Features y Approval / Certification: TÜV per VDI – 2053 (Air treatment systems for car parking) y Detection principle: Electro-chemical y Humidity range: 15 - 95% relative humidity, non condensating y Operation: Continuous y Signal: 4-20 mA, max. load 300Ω y Gas entry: by diffusion y Connection: 2 – wire y Measuring range: 0-300 ppm CO in air y Zero adjustment: Automatic, calibration free y Reproducibility : < 3 ppm y Sensitivity adjustment: via potentiometer y Response time 90: < 60 sec y R.F.I According EN 50 081-1 resp. y Cross sensitivity: < 2% on 300 ppm CO according VDI 2053 y Linearity: < 2% on 300 ppm CO according VDI 2053 Wiring diagram 12-2 y Operating temperature range: -10°C to +40°C www.meitavtec.com | [email protected] EN 50 082-2 B y Filter: For dust and water protection HVAC Analyzers M4000MD HVAC Analyzer, measures inlet and outlet variables, for an intelligent analysis of HVAC performance The M4000MD HVAC Analyzer is a diagnostic instrument for a wide range of applications. It consists of two units; a large LCD display and a hand held sensor connected by a coiled command cable. The M4000MD measures all HVAC inlet and outlet variables, allowing for an intelligent analysis of system performance. The M4000MD is an excellent tool for every HVAC technician allows readings both in Metric or English values. Features y The M4000MD measures: y Allows measurement of Rectangular and Round Grills * Temperature (°C/°F) * Humidity (%RH) y Three, simple keypads operate all functions * Dew Point (°C/°F) y Low Battery Indication * Air Velocity (FPS or M/S) * Air Volume (CFM or M³/S) * Energy Capacity in BTU/HR or KW y Direct Read-out – no additional calculations needed y Audible and Visual Prompts y Memory holds cumulative volume and power measurements for multi grills calculations y 9V Battery Operated www.meitavtec.com | [email protected] 13-1 12-2 www.meitavtec.com | [email protected] Special Controllers EC-300 230VAC, Energy Controller for energy saving in offices AC or hotel rooms. Turns off/on HVAC + lighting systems per presence in a room via an Occupancy Sensor and FC optional Contact Inputs The EC-300 is a smart Energy Controller, which offers substantial energy saving of Air Conditioning & Lighting operation in hotel bedrooms, offices or conference rooms. ECONOMY Since hotel bedrooms have different needs from offices + regarding occupancy changes, the EC-300 allows different configurations for them. In both applications, presence detection is achieved via an Infra Red Occupancy sensor; if the IR sensor detects no presence within a certain, configurable time, the EC will cut off electricity to HVAC & Lighting systems. Upon detection, EC will automatically re-operate the systems. Further energy saving is achieved by cutting off electricity to HVAC system if someone opens the window, or if set temperature exceeds the Limit Cool or Limit Heat. For Hotels, additional Contact Input, a door switch, or other Normally Closed input is employed to stop HVAC, Lighting or both. Features y Power supply - 230VAC, 10A for HVAC operation y Detects presence based on an IR Occupancy sensor + Contact Inputs on door entry or window y Easy, quick installation at voltage line, between an existing HVAC & lighting system and Power Supply y Inputs: * IR Occupancy sensor – turns off HVAC and lights after adjustable time, separate for HVAC and lights * Window contact (X2) – N.O. or N.C selectable * Door switch – enables special logic for hotel rooms * Temperature sensors – enable Temperature Limits, Cool & Heat set limits are adjustable y EC installation requires no modification in the existing room devices y No decline in convenience to user y Controller supplies 12VDC voltage to IR sensor y EC set contains Controller + IR sensor y DIP switch selectable options: * Hotel or Office configuration (Door switch active or not for logic) * With or without compressor delay * Window contact configuration (N/O or N/C) y Maximum energy saving Wiring diagram www.meitavtec.com | [email protected] 14-1 Special Controllers Lead-Lag Controller Lead-Lag Controller for 2 complete units, with AC On/Off cycling every 24 hrs. The Lead-Lag controller is the most efficient way of COOL controlling temperature in a remote location where both a primary cooling unit and a back-up cooling unit are used. EXT. SENSOR OPTION The Lead-Lag controller controls 2 different units, treating them as 2 different stages, and allows them to cycle On and Off every 24hrs. This ensures that the TIMER desired room temperature is always maintained and also prevents wear of the units. COMPRESSOR DELAY With a 4°C differential kept always between room temperature and set temperature, the Lead-Lag controller is ideal for environments, such as computer rooms and other rarely visited rooms. Features y Main Supply - 230VAC y Auto switch-over from one unit to the other every 24 hrs. y In Auto mode, the 2 units (on-duty and off-duty) are treated like 2 stages y On-duty unit compressor cycles between “On” and “Off” depending on room temp. and set temp. y Time delay for compressor protection y 4°C always maintained between room temp and set temp- off-duty unit will start operating, if necessary. Wiring diagram 14-2 www.meitavtec.com | [email protected] y Manual switch-over (3 positions) between “Auto”, “Off” and “Manual” y Display of ambient temperature on a wall-mount room thermostat (ETN). y Fault indication when ambient temperature rises above 28°C. y External sensor for ambient room temperature. Special Controllers M6000-T1-T2-AN 230VAC, Multi Stage Controller, with 6 programmed AC outputs + analog inputs, for large applications The M6000-T1-T2-AN controller is the best multi-stage COOL display controller on the market today. As opposed to many complicated units, the M6000-T1-T2-AN makes it incredibly easy to pre-set stages and all other parameters. This, plus the 6 individually programmed outputs, gives users a unique ability to “custom-build” their entire HVAC control system. C The M6000-T1-T2-AN offers the following: * 6 outputs- fully programmable * 2 outputs for On Indication (may activate fan) TIMER * Input for 2 temperature sensors to be used FAULT INPUT separately for each output (Meitav-tec's sensors) * Analog Inputs (0-10VDC) to be used separately for each output (humidity, pressure, water flow, etc) PROG The M6000-T1-T2-AN is suitable for even the largest of M6000 (12V) + PS104 applications, such as chillers and big air-handling units. ECONOMY EXT. SENSOR OPTION Features * Logic for output- Cool or Heat Main Supply - 230VAC with power supply Ex: Humidifier- If Heat is selected, output Range temperature from 0°C-65°C will be activated only if set point is Higher Range set point for each output 0°C-60°C than actual humidity * Compressor delay – Yes or No y 6 programmable outputs, each output corresponds to a stage. Parameters that can be set are: y Analog input can be set for different scales * Set point (0 to 100 as % or 0 to adjustable) * Input to operate by: Analog, T1 or T2 (2 different y Fault input – Normally Open (all unit OFF) temperature sensors) – inputs may be combined Energy saving – cost efficient, environmental friendly controller * Differential (ΔT between stages) y All outputs have Random start Analog input (option) T2 Sensor (option) T1 Sensor (option) 230VAC Main input ON Indication (fan) Out 6 Out 5 Out 4 Out 3 Out 2 Out 1 Wiring diagram www.meitavtec.com | [email protected] 14-3 Special Controllers FCC_01 - Free Cooling Controller Wall mount, 230VAC controller, for Cooling AC with outside fresh air – saves energy and refreshes room air. Meitav-tec's 'Free Cooling' controller offers a simple, energy saving solution to control room temperature. COOL 'Free Cooling' is virtually a Cool Only thermostat, which serves as a complementary to an existing HVAC control system. The thermostat is designed to EXT. SENSOR OPTION take advantage of natural resources to cool room temperature; if outside temperature is cooler than ambient then the Free Cooling thermostat sends a signal to open a window or a damper to let fresh, cool air come in, and cool the room. Features y Wall mount – 230VAC thermostat y Difference between ambient and room y Open / Auto / Close switch (for damper, fan or window) jumper configured (Default is 1°C) y External / Internal room sensor – jumper y Outside temperature sensor input y Can work as a “stand-alone” or next to another HVAC system Wiring diagram T HI RE LO ME 230VAC power supply 0 output 3A 0 ~ ~ room temp. outside external temp. sensor sensor (option) Free Cooling 14-4 y Energy saving controller y Aesthetic shaped controller selectable T temperature, to open the window, is www.meitavtec.com | [email protected] Special Controllers TLC 230VAC (available also in 24VAC version), Temperature Limit Controller for energy saving. Turns off/on compressor as per adjustable temperature limits. The TLC is a simple, yet efficient Temperature Limit Controller which offers substantial energy saving of Air Conditioning by limiting ‘Set Temperature’. The TLC is compact and easy to install at any existing AC system by connecting the compressor relay line to the TLC, the TLC overrides the AC control system and therefore can limit the Cool/Heat set points. Limit Cool & Limit Heat values are configurable. If ambient temperature from the return air sensor exceeds the predefined limits, the compressor will stop working. The TLC will automatically re-operate the compressor according to these values. The TLC allows significant energy saving in both commercial or residential applications while investment is minimal and installation is quick and simple. Features y Energy Saving, cost effective Controller y Adjustable temperature limits for Cool / Heat using 2 manual knobs y Power supply - 230VAC for HVAC operation y Easy, quick installation for any existing AC y 1A, 230Vac dry contact for compressor relay y With or without compressor delay (to protect compressor) – jumper selectable y TLC installation requires no modification in the existing room devices y No decline in convenience to user y Return On Investment (ROI) is fast Wiring diagram www.meitavtec.com | [email protected] 14-5 14-6 www.meitavtec.com | [email protected] Sensors and Accessories DT-02 Duct Sensor Duct sensor in a plastic enclosure Suitable for all Meitav-tec's thermostats Features y Dimensions: y Range - -40°C to 110°C ; 39°F to 230°F * width - 45 mm * height – 38 mm * depth – 20 mm y Thermistor type - NTC * rod length – 155 mm y Standard – UL94V-0 y Measurement accuracy - ±3% y Weight: 14 gr. y Color – white y Resistance – 25C; 77F = 50 KΩ y Plastic - ABS y Thermal Time Rate – 15 seconds Wiring Diagram www.meitavtec.com | [email protected] 15-1 Sensors and Accessories GHU Room/Duct Sensor General purpose stand-alone humidity and 0-10V temperature sensor for room or duct. OUTPUT GHU Room Sensor The GHU Room or Duct sensors are general purpose, all-in-one™ sensors for both temperature and humidity. HUMIDITY Humidity measurement is given as a proportional output, 0-10VDC while temperature reading may be given in one of two ways: 1. Normally via a thermistor (for controllers that do not offer 0-10VDC temperature inputs- temperature sensor used must be Meitav-tec type) 2. GHU Duct Sensor As a proportional signal (0-10VDC) With wide temperature and humidity ranges, the GHU Room / Duct sensors are practical and ideal solutions for all room and duct applications. Features y Main Supply – 24VAC or 12VDC y Proportional temperature output- 0-10VDC y Proportional humidity output- 0-10VDC Wiring Diagram 0 Temp. 0-10V Hum. 0-10V Temperature sensor 15-2 www.meitavtec.com | [email protected] y Temperature set point range from 0°C-60°C / 32°F-140°F (0-10VDC) y Humidity set point range from 15%-90% RH (0-10VDC) Sensors and Accessories TS-01 & TS-02 Temperature Sensors TS-01 External Temperature Sensor, 80 cm cable TS-02 External Temperature Sensor, 180 cm cable Features y Cable 2 wire – AWG 24 BLACK y Thermal Time Rate – 15 seconds y Thermistor color – silver or brass y Range - -40°C to 110°C ; 39°F to 230°F y Dims of Thermistor 1" x 0.25" (2.5 cm x 0.6 cm) y Thermistor type - NTC y Resistance – 25C; 77F = 50 KΩ TS-05 & TS-06 Temperature Sensors TS-05 External Temperature Sensor, 80 cm cable TS-06 External Temperature Sensor, 300 cm cable Thermistor is coated with isolating plastic. Other technical specifications are the same as TS-01 & TS-02. www.meitavtec.com | [email protected] 15-3 Sensors and Accessories RS-01 Temperature Sensor External Temperature Sensor in a decorative box External temperature sensor in a wall mount, decorative box. Suitable for all Meitav-tec's thermostats Features y Cable 2 wire – AWG 24 BLACK y Thermal Time Rate – 15 seconds y Dimensions – 1.8" x 1.5" (46 mm x 38 mm) y Range - -40°C to 110°C ; 39°F to 230°F y Resistance – 25C; 77F = 50 KΩ y Thermistor type - NTC RS-02 Average Temperature Sensor Average Temperature Sensor in a decorative box y Ideal for wide, open space hall where temp. differs in each location y 2 units required for average measurement of Temperature y Provides average room temperature, using external sensors, installed in two different locations y Each temperature sensor installed in a wall-mount, decorative box y Suitable for all Meitav-tec's thermostats y Technical Specifications are the same as RS-01. 15-4 www.meitavtec.com | [email protected] Sensors and Accessories RT03 Remote Control Hand held remote control unit, for Meitav-tec's thermostats and controllers. HEAT An infra-red remote controller, suitable for Meitav-tec's thermostats and receivers. Easy-to-use, with big LCD and a large temperature digit display. Features TIMER y On/Off y Timer - Start / Stop y Modes: Cool / Heat / Auto-change-over / Fan only y Real time clock & day y Fan speeds: High / Medium / Low / Auto y 2 X AAA battery operated y Temperature set point y Elegant Housing for wall mounting y °C or °F temperature scale y Available in black or white panel AUTO CHANGE-OVER RT04 Remote Control Hand-held remote control for programmable COOL thermostats, with USA weekly program HEAT An infra-red, remote controller, suitable for programmable thermostats. Easy-to-use, with big LCD and a large AUTO CHANGE-OVER temperature digit display, °F display. F Features y On/Off y Up to 6 different weekly programs y Modes: Cool / Heat / Auto change-over / Fan only y Timer y Temperature set-point y Real time clock y °F temperature scale y 2 X AAA battery operated y 2 or 4 periods a day, each with a different set point y Available in black or white panel TIMER www.meitavtec.com | [email protected] 15-5 Sensors and Accessories RT05 Remote Control Hand-held remote control for programmable thermostats, with European weekly program HEAT An infra-red, remote controller, suitable for programmable AUTO CHANGE-OVER thermostats. Easy-to-use, with big LCD and a large temperature digit display, °C display. PROG C Features y On/Off y Up to 6 different weekly programs y Modes: Cool / Heat / Auto change-over / Fan only y Timer y Temperature set-point y Real time clock y °C temperature scale y 2 X AAA battery operated y Up to 4 start /stop a day, each with a different set y Available in black or white panel TIMER point RT40/41 Remote Control Hand-held remote control for stand-alone dampers, for Meitav-tec’s receivers COOL An infra-red remote controller, suitable for standalone dampers. Easy-to-use, with big LCD and a HEAT large temperature digit display. C F Features y On/Off y °C or °F temperature scale y Modes: Cool / Heat y Real time clock & day y Temperature set point y Elegant Housing for wall mounting y Timer - Start / Stop, hour & minute display y Available in black or white panel y 2 X AAA battery operated Note: RT41 Remote Control model has the same specifications as RT40, but with no Modes or Timer. It has hour display only. 15-6 www.meitavtec.com | [email protected] Power Supplies PS-102 230VAC – 12VDC, Power Supply The PS-102 is a power supply for HVAC system. It converts 230VAC to 12VDC for thermostat operation and through relays, transfers commands from thermostat to operate 230VAC HVAC system. It offers 7 relay outputs to control HVAC system and 3 inputs for Temperature Sensors. Features Wiring Diagram y Main Supply - 230VAC PS102 y 7 x 230VAC outputs – each 6A (resistive), or 3A (inductive), total ≤ 9A y 7 x 12VDC inputs y 3 inputs for temperature sensors To thermostat (12VDC) y Inputs & outputs are terminal blocks, screw connector y PS-102 is supplied in a plastic enclosure box 12VDC supply (to thermostat) 21 RL 7 17 1 22 RL 6 16 18 2 RL 5 15 3 RL 4 14 4 RL 3 13 5 RL 2 12 6 RL 1 11 7 + 8 + POWER SUPPLY 12VDC 9 Sensors 10 Fuse 10A ~ 0 20 To system (230VAC) 230VAC Main input T1 T1 T2 T2 T3 T3 Sensors PS-24 24VAC - 230VAC –Power Supply Ideal for 230VAC Fan operation in 24VAC HVAC systems The PS-24 is a power supply for HVAC system. It converts 24VAC to 230VAC thorough relays for fan operation and transfers commands from thermostat to operate 24VAC HVAC system. All in all, it offers 3 relay 230VAC outputs to control HVAC fan system and 4 x 24VAC inputs, directly transferred to 24VAC outputs. Features Wiring Diagram y Main Supply - 230VAC y 3 x 230VAC outputs + 4 x 24VAC outputs y 7 x 24VAC inputs + 1 Temperature input y Inputs & outputs are terminal blocks, screw connector y PS-24 is supplied in a plastic enclosure box www.meitavtec.com | [email protected] 16-1 Power Supplies PS-104 230VAC – 12VDC, Power Supply The PS-104 is a power supply for HVAC system. It converts 230VAC to 12VDC for thermostat operation and through relays, transfers commands from thermostat to operate HVAC system. It offers 8 relay outputs to control HVAC system and 3 inputs for Temperature Sensors. Features Wiring Diagram y Main Supply - 230VAC y 8 x 230VAC outputs – each 6A (resistive), or 3A (inductive), total ≤ 9A y 7 x 12VDC inputs To thermostat (12VDC) y 3 inputs for temperature sensors y Inputs & outputs are terminal blocks, screw 12VDC supply (to thermostat) connector 22 RL 8 18 21 RL 7 17 3 RL 6 14 1 RL 5 16 2 RL 5 15 4 RL 3 13 5 RL 2 12 6 RL 1 11 7 + 8 - 9 Sensors 10 + POWER Fuse 10A SUPPLY 12VDC ~ 0 20 T1 T1 T2 T2 T3 T3 Sensors PS-600 230VAC – 24VDC, Power Supply Ideal for 230VAC HVAC units operated by 24VAC The PS-600 is a power supply for HVAC system. It converts 230VAC to 24VDC for thermostat operation and through relays, transfers commands from thermostat to operate the 230VAC HVAC system. It offers 6 relay outputs to control HVAC system controllers Features y Main Supply - 230VAC y 6 x 230VAC outputs – 3 outputs 3A and 3 outputs 1A y 6 x 24VDC inputs y 10 direct input-output connections low Voltage (24V) y Inputs & outputs are terminal blocks, screw connector y PS-600 is supplied in a plastic enclosure box 16-2 www.meitavtec.com | [email protected] Wiring Diagram To system (230VAC) 230VAC Main input CTU Communication Controller 230VAC, 115VAC, 24VAC Specifications Temperature Range Accuracy +1 Weight 0.545 Kg Plastic PC/ABS Color gray Flammability UL94V-0 204 .5 m m 92 mm www.meitavtec.com | [email protected] B-1 ERT Wall mount thermostat 230VAC Specifications Temperature Range 10°C ÷ 30°C , 50°C ÷ 86°F Accuracy ±1°C Weight 0.25 Kg Plastic PC/ABS Scale °C / °F Flammability UL94V-0 Color white Temperature Input 50K@25°C 83mm 45mm B-2 www.meitavtec.com | [email protected] 30mm ETN (non programmable) Wall mount thermostat/panel 24VAC, 12VDC Colors white silver black gold others Accessories TS01 RS01 RS02 WP4 RS03 Specifications Temperature Range 10°C ÷ 30°C, 50°C ÷ 86°F Accuracy ±1°C Weight 0.25 Kg Plastic PC/ABS Scale °C / °F Flammability UL94V-0 Color white, silver, black, others Temperature Input 50K@25°C 80mm Front view Side view 92mm 22mm 80mm www.meitavtec.com | [email protected] B-3 ETN (programmable) Wall mount thermostat/panel 24VAC Colors white silver gold black others Accessories TS01 RS01 RS02 Specifications Temperature Range 5°C ÷ 35°C Accuracy ±1°C Weight 0.125 Kg Plastic PC/ABS Scale °C / °F Flammability UL94V-0 Color white, silver, black, others Temperature Input 50K@25°C 80mm B-4 www.meitavtec.com | [email protected] Front view Side view 92mm 22mm 80mm WP4 RT03 FMH Flush Mount thermostat/panel 24VAC, 220VAC, 110VAC Colors white silver gold black others Accessories TS01 RS01 RS02 DT02 RT03 Specifications Temperature Range 10°C ÷ 30°C , 50°C ÷ 86°F Accuracy ±1°C Weight 0.200 Kg Plastic PC/ABS Scale °C / °F Flammability UL94V-0 Color white, silver, black, others Temperature Input 50K@25°C Front view Side view Back view 6mm (max) 118mm 75mm O C 80mm Cool Hi ON Heat Med Lo ON OFF MODE 53mm FAN 35mm (inside the wall) www.meitavtec.com | [email protected] B-5 FMT(non programmable) Flush mount vertical thermostat/panel 24VAC , 220VAC, 110VAC Accessories TS01 RS01 RS02 Specifications Temperature Range 10°C ÷ 30°C, 50°C ÷ 86°F Accuracy ±1°C /±1.5°F Weight 0.200 Kg Plastic PC/ABS Scale °C / °F Flammability UL94V-0 Color white Temperature Input 50K@25°C / 77°F Front view 80mm Side view Back view 6mm (max) 53mm 118mm 75mm ON SELECT 35mm (inside the wall) B-6 www.meitavtec.com | [email protected] RT03 MIGA Main Controller ALL-IN-ONE™ 230VAC Accessories ETN-Miga FMH-Miga TS01 MP101 M1P RT03 Specifications Temperature Range 10°C ÷ 30°C Accuracy ±1°C Weight 0.400 Kg Plastic PC/ABS Scale °C / °F Flammability UL94V-0 www.meitavtec.com | [email protected] B-7 PS (Communication Controller) Main Controller 230VAC, 115VAC, 24VAC Accessories FMH-X500 IRP-X500 FMT-X500 ETN-X500 RS01 RS02 Specifications B-8 Temperature Range 10°C ÷ 30°C Accuracy ±1°C Weight 0.340 Kg Plastic PC/ABS Scale °C / °F Flammability UL94V-0 www.meitavtec.com | [email protected] RS03 TED (without display) Wall mount, mechanical thermostat 220VAC, 24VAC Accessories TS01 RS01 RS02 WP1 Specifications Temperature Range 10°C ÷ 30°C Accuracy ±1°C Weight 0.150 Kg Plastic PC/ABS Scale °C Flammability UL94V-0 Color white Temperature Input Thermistor 50K@25°C 125mm 106mm 10mm www.meitavtec.com | [email protected] 30mm B-9 TED (with display) Wall mount, mechanical thermostat 220VAC, 24VAC Accessories TS01 RS01 RS02 WP1 Specifications Temperature Range 10°C ÷ 30°C Accuracy ±1°C Weight 0.150 Kg Plastic PC/ABS Scale °C Flammability UL94V-0 Color white Temperature Input Thermistor 50K@25°C 125mm B-10 www.meitavtec.com | [email protected] 106mm 10mm 30mm Contact Us For questions regarding technical or marketing issues, please contact us at: Address: Meitav-tec Ltd. (Contel Group) 6, Sapir street, New Industrial Zone P.O.B 5221 Rishon Le’Zion, 75150, Israel Tel: +972-3-9626462 Fax: +972-3-9626620 Web: www.meitavtec.com E-mail: [email protected] www.meitavtec.com | [email protected] C Product Index B BDIR-24-SUPER-PROG C CEM-24-SUPER CEO-24-HC22 CEV-24-SUPER CHU-24-SUPER CO Detector CTR-24-SUPER CTU1601 CTU1800-PM2-3S-FC-SUPER - Maxinet protocol CTU2500-P-3S-FC-SUPER – BACnet Protocol CTU2601 – BACnet Protocol CTU4500-P-3S-FC-SUPER – Modbus Protocol CTU4500-PM2-3S-FC-SUPER - Modbus Protocol CTU4601 D DA-24-3W DA-401 - Stand Alone Dampers DEH-2000 DT-02 Duct Sensor E EC-300 ERHU-55 ERT100-LCD-IR ERT-208 ERT-209 ETN-24-AZC ETN-24-HC21-PROG-ECO ETN-24-HC21-PROG-OA ETN-24-HC21-PROG-TS ETN-24-P/PD-FC-SUPER2 ETN-24-P/PM-1S (Cool Only) ETN-24-P-1S (Cool Only) ETN-24-P-3S-HU ETN-24-PH-FC-SUPER ETN-24-PM2 series ETN-24-PMH series ETN-24-SUPER-3S-FP-PROG-EU-C ETN-24-SUPER-PROG-7DAYS-US Series ETN-24-SUPER-PROG-EU Series ETN-24-SUPER-PROG-US Series ETN-24-SUPER-SF ETN-24-SUPER-SH ETN-24-SUPER-SI ETN-40P1 ETN-C-24-SUPER- Maxinet protocol ETN-MIGA-IR ETN-X500 F FCC_01 – Free Cooling Controller FE-340-H1 FE-340-H1-PAR-45 FE-340-H1-PAR FHV-H1-PR-IR FMH-220-HC11-3S-IR FMH-220-HP11-3S-IR FMH-220-P-FC-SUPER FMH-24-C2-3S-IR FMH-24-P-1S FMH-24-PD-1S FMH-40P1 FMHC220-FC-MDB03 - Modbus Protocol FMHC220-P-FC-MDB01 - Modbus Protocol FMH-FC-SUPER3 FMH-FC-SUPER4 FMH-MIGA-IR 2-10 2-12 2-11 2-13 4-1 12-2 2-9 7-13 7-11 8-9 8-31 8-19 8-21 8-32 10-6 10-5 4-3 15-1 14-1 4-2 1-10 1-8 1-9 10-1 2-6 2-7 2-8 3-1 3-11 3-6 4-4 3-2 3-9 3-10 2-1 2-3 2-2 2-4 1-3 1-1 1-2 10-3 7-2 5-5 8-24 14-4 11-1 11-3 11-2 11-4 1-6 1-4 5-3 1-5 3-3 3-4 10-4 8-23 8-28 5-1 5-8 5-6 F FMH-X500 FMT-24-AZC-Proportional-IR FMT-24-PD-3S FMT-24-SUPER FMT-24-SUPER-PROG FMT-X500 G GAQ - Air Quality Controller & Sensor Series GHU Room/Duct Sensor I IRP-401 IRP-X500 + RT03 L Lead-Lag Controller M M1P M4000MD M5001-24-4X0-10VDC M5003-24VAC/12VDC M6000-T1-T2-AN MCU MIGA AB MIGA1-AC-SUPER MIGA1-FC-SUPER P PS 2007 - Multi-Zone System control system PS-102 PS-104 PS1600 PS1800-AC-SUPER - Maxinet protocol PS1800-FC-SUPER - Maxinet protocol PS1800-FC-SUPER-02 - Maxinet protocol PS1800-P-FC-SUPER - Maxinet protocol PS-1800-PM2-3S-FC-SUPER - Maxinet protocol PS-24 PS2500-3S-FC-SUPER –BACnet Protocol PS2500-P-3S-FC-SUPER – BACnet Protocol PS2500-PM2-3S-FC-SUPER – BACnet Protocol PS2500-TA2-3S-FC-SUPER – BACnet Protocol PS4500-3S-FC-SUPER –Modbus Protocol PS4500-AC-SUPER-02-WET – Modbus Protocol PS4500-P-3S-FC-SUPER – Modbus Protocol PS4500-PM2-3S-FC-SUPER – Modbus Protocol PS4500-TA2-3S-FC-SUPER – Modbus Protocol PS-600 PS8-FH + ETN-8H PSMZ-100/200 for Multi-Zone System PS-MZ502 Multi-Zone System R RS-01 Temperature Sensor RS-02 Average Temperature Sensor RT03 Remote Control RT04 Remote Control RT05 Remote Control RT40/41 Remote Control T TED-220-C1-3S TED-220-HC11-3S TED-220-HP11-3S TED-24-AUTO-SUPER TED-24-P-3S (FAN 230 VAC) TED-24-P-3S-Cool Only (FAN 230 VAC) TED-24-SUPER TES-220-HC11-3S TLC TS-01 & TS-02 Temperature Sensors TS-05 & TS-06 Temperature Sensors 8-25 10-2 3-5 1-7 2-5 8-26 12-1 15-2 10-4 8-27 14-2 5-7 13-1 4-6 4-5 14-3 7-1 5-9 6-1 5-4 9-3 16-1 16-2 7-14 7-3 7-5 7-15 7-7 7-9 16-1 8-1 8-3 8-5 8-7 8-11 8-29 8-13 8-15 8-17 16-2 11-5 9-1 9-5 15-4 15-4 15-5 15-5 15-6 15-6 1-14 1-12 1-11 1-15 3-7 3-8 1-13 1-16 14-5 15-3 15-3 Specifications and product availability are subject to change without notice. Specifications and feature sets are for technical information only and are not legally binding. www.meitavtec.com | [email protected] D