Preview only show first 10 pages with watermark. For full document please download

Memoright Confidential

   EMBED


Share

Transcript

l Multi-Temp SATA SSD 2.5” en tia STM-25 M em or ig ht co nf id SATAII-3.0 Gb/s Industrial Temperature Grade Revision: V01 Memoright Corp. Date: MayZhong 2013 9F,535, Zheng Rd, Xin Dian Dist., Memoright reserves the right to change products or specifications without notice. Revision: V01 New Taipei City, Taiwan Page 1 of 26 STM-25 Multi-Temp SATA Solid State Drive 2.5” – STM-25 Series 32 GB 1. Features  100.2 mm x 69.85 mm 9.5 mm  Totally compliant to standard SATA hard disk drive  7+15 pin (SATA power) SATA connector Available Capacities    Supported max. to UDMA6  Supported max. to PIO mode 4.  MLC NAND Flash ECC     nf id Highly integrated controller for NAND Flash memory co  32 GB (MLC NAND Flash) l 2.5” SATA solid State Drive (SSD) en tia  ht  Form Factor BCH 16/24 bits ECC M em or ig  High Performance  Up to 300 MB/s burst transfer rate in SATAII, 3 Gb/s  Sustained Read Performance: up to 173 MB/s  Sustained Write Performance: up to 45 MB/s High Reliability  MTBF > 2,100,000 hours  Endurance: > 3 years sequential write (for a half drive’s capacity write per day)  Dynamic, static and active balanced wear-leveling strategy  Bad-Block Management  S.M.A.R.T support Temperature Ranges  Industrial Temperature Range: -40℃ ~+85℃ Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 2 of 26 STM-25 2. Contents Features...................................................................................................................................................... 2 2. 3. Contents .................................................................................................................................................. 3 Ordering Information............................................................................................................................ 4 3.1 Part Number Decoder .......................................................................................................................... 5 4. 8. General Description ............................................................................................................................. 6 4.1 Physical Description ................................................................................................................... 6 4.2 System Performance .................................................................................................................. 7 4.3 Environmental Specifications .................................................................................................... 7 4.4 Reliability ...................................................................................................................................... 8 4.5 Physical Dimensions................................................................................................................... 8 4.6 CHS Parameter ........................................................................................................................... 8 4.7 Drive Geometry............................................................................................................................ 8 Functional Block Diagram .................................................................................................................. 9 Physical Dimension Diagram........................................................................................................... 10 Electrical Interface .............................................................................................................................. 11 7.1 Electrical Description ................................................................................................................ 11 Feature Descriptions .......................................................................................................................... 13 9. 8.1 Wear Leveling ............................................................................................................................ 13 8.2 Bad Block Management ........................................................................................................... 13 8.3 Endurance .................................................................................................................................. 13 8.4 ECC ............................................................................................................................................. 13 8.5 Standards Compliance ............................................................................................................. 13 Supported ATA Commands ...................................................................................................................... 14 nf id co M em or ig ht 5. 6. 7. en tia l 1. 9.1 ATA Command Specifications ................................................................................................. 15 10. Memoright SSD Marking Information.............................................................................................. 25 10.1Top View.......................................................................................................................................... 25 11. Contact Information ................................................................................................................................... 26 Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 3 of 26 STM-25 3. Ordering Information The following Table 1 lists the part No. for Memoright STM-25 series SSDs. Table 1: Industrial temperature product list Part Number MRSAJ6C032GCQ25I01 Capacity Flash Type Form Factor 32 GB* MLC 2.5” * 1 GB=1,000,000,000 Bytes M em or ig ht co nf id en tia l For latest ordering information, please consult Memoright’s sales representatives or check on our website: http://www.memoright.com Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 4 of 26 STM-25 3.1 Part Number Decoder MR S A J6C 1 2 **** C* 25 I 01 3 4 5 6 7 MR: Memoright en tia l SAJ6C: STM-25 Series Capacity Temperature Option I: Industrial (-40℃~85℃) M em or ig ht co nf id 032G: 32 GB 01: Customized Product Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan 25: 2.5” Form Factor Flash Type: MLC Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 5 of 26 STM-25 4. General Description The Memoright STM-25 series SSD provides you ultimate performance and ultra-high reliability over traditional hard disk drive by achieving up to 173 MB/s/45 MB/s sequential read/write rate and integrated protection technologies such as bad block management, wear-leveling. The above-mentioned features made Memoright STM-25 series SSD the best solution for various consumer electronics and industrial applications. For reliability, Memeoright STM-25 series SSD integrates dynamic, static and active (inactive) balanced wear leveling technology to ensure an equal usage of the Flash memory cells to extend the SSD life time. Moreover, it provides features such as Enhanced ECC algorithm, bad block management algorithm and MTBF>2,100,000 hours to assure overall reliability. Physical Description M em or ig 4.1 ht co nf id en tia l Memoright STM-25 series SSD consists solely of semiconductor devices, which means it doesn’t have any mechanical part such as platter (disk), motor and suspension as traditional hard disk drive. Its characteristics such as high performance, capacity, reliability, ruggedness, low power consumption and small form factor make it the best storage solution not only for portable computing devices such as Tablet PC and UMPC but also for industrial application with extreme environment and increased MTBF requirements. Due to Memoright STM-25 series’ SATA interface and 2.5” form factor, it is the best solution to replace traditional 2.5” HDD. The important component of Memoright STM-25 SSD includes a Flash controller and NAND Flash memory modules. The controller works with a host system to allow data to be written to and read from the Flash memory modules through a (SATA) interface. The SSD is offered in a 2.5” form factor with a SATA connector. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 6 of 26 STM-25 4.2 System Performance Table 2: System Performance Table System Performance Max. Unit Data transfer Rate (SATA burst (3 Gb/s) 300 MB/s Sustained Sequential Read Rate 32 GB* 173 MB/s Sustained Sequential Write Rate 32 GB* 45 MB/s 4KB Random Read IOPS 32 GB* 12,000 IOPS 4KB Random Write IOPS 32 GB* 600 IOPS *1 GB=1024 Mega Byte 4.3 Environmental Specifications en tia l 4.3.1 Recommended Operating Conditions Table 3: Recommended Operating Conditions Parameter Value -40℃ to 85℃ nf id Industrial Operating Temperature Temperature Gradient (℃ per hour max, non-condensing) 20℃ (operating) Temperature Gradient (℃ per hour max, non-condensing) 30℃ (non-operating) M em or ig Table 4: Power Consumption 5V ht 4.3.2 Power Consumption (*) co Power Supply Voltage Range Current/Power Consumption 5V Unit 2 (Transient) A Continue Read Power (Average) <3 W Continue Write Power (Average) <3 W Idle Mode Power (Average) <800 mW Standby Mode Power (Average) <800 mW Input Current (Max.) * All values are tested under room temperature 25℃ @ 5V. The power consumption may vary depends on different platform, OS, BIOS & test tools. 4.3.3 Recommended Storage Conditions Table 5: Recommended Storage Conditions Parameter Industrial Storage Temperature Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Value -55℃ to 95℃ Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 7 of 26 STM-25 4.3.4 Shock, Vibration and Humidity Table 6: Shock, Vibration and Humidity Parameter Value Humidity (non-condensing) 5%~95% (Operating) Relative Humidity Gradient 30% per hour max Vibration 10G (Peak, 10~2000Hz) Shock (Operating) 50G, (11ms duration, half sine wave) Shock (Non-Operating) 4.4 1500G, (0.5ms duration, half sine wave) Reliability Table 7: Reliability Value > 2,100,000 hours (Calculation mode: en tia l Parameter Mean Time Between Failures (MTBF) Telcordia SR-332 Issue 1 Method 1, Case 1) 4.5 10 years nf id Data Retention Physical Dimensions co Physical Dimensions Length 4.6 M em or ig Thickness ht Width Unit 100.2 mm 69.85 mm 9.5 mm CHS Parameter Unformatted Capacity 32 GB* Guaranteed Sectors Bytes per Sector 58,626,288 512 *1GB=1,000,000,000 Bytes 4.7 Drive Geometry Capacity Default Cylinders Default Heads Default Sectors 32 GB* 58161 16 63 Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 8 of 26 STM-25 5. Functional Block Diagram M em or ig ht co nf id en tia l Figure 1: Functional Block Diagram Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 9 of 26 STM-25 6. Physical Dimension Diagram M em or ig ht co nf id en tia l Figure 2: Physical Dimension Diagram Physical Dimensions Length Width Thickness Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Unit 100.2 mm 69.85 mm 9,5 mm Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 10 of 26 STM-25 7. Electrical Interface 7.1 Electrical Description co nf id en tia l The drive uses the industry-standard Serial ATA interface that supports 16-bit data transfers. It supports programmed input/output (PIO) modes 0–4; Ultra DMA modes 0–6. The drive also supports the use of the IORDY signal to provide reliable high-speed data transfers. For detailed information about the Serial ATA interface, refer to the draft of AT Attachment with Packet Interface Extension (ATA/ATAPI-7), NCITS T13 1410D, subsequently referred to as the Draft ATA-7 Standard. For detailed information about the Serial ATA interface, refer to the draft of AT Attachment with Packet Interface Extension (ATA/ATAPI-7), NCITS T13 1410D, subsequently referred to as the Draft ATA-7 Standard. The connector on Memoright SATA STM-25 Series SSD is divided into a signal Segment and a power Segment. The following tables summarize the signals on the SATA interface connector. For a detailed description of these signals, refer to the Draft ATA-7 Standard. Please see following Figure and table for signal and power pin assignment. M em or ig ht Figure 3 SATA pin Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 11 of 26 STM-25 Table 8 Pin Assignment and description for Signal and Power pins Signal Name Description S1 Ground Second Mate S2 R+ +Differential Receive Signal S3 R- -Differential Receive Signal S4 Ground Second Mate S5 T- -Differential Transmit Signal S6 T+ +Differential Transmit Signal S7 Ground Second Mate Pin Name Signal Name Description P1, P2,P3 V3.3 3.3V Power(Not used) P4 Ground First Mate P5 Ground P6 Ground P7 V5 P8 V5 5V power P9 V5 5V power Ground Second Mate P14 P15 Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Second Mate Second Mate 5V power, pre-charge, second Mate Reserved Reserved Ground First Mate V12 12V Power(Not used) V12 12V Power(Not used) V12 12V Power(Not used) M em or ig P11 P13 en tia nf id co ht P10 P12 l Pin Name Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 12 of 26 STM-25 8. Feature Descriptions 8.1 Wear Leveling 8.2 Bad Block Management 8.3 Endurance 8.4 ECC 8.5 Standards Compliance For extending SSD’s life time, a sophisticated wear leveling technology is important. Memoright STM-25 series provides dynamic, static (initiative) balanced wear leveling strategy. The dynamic wear leveling algorithm ensures that erase/write cycles can be evenly distributed across all flash memory block locations to prevent excessive writes to the same physical flash memory location. en tia l Memorigt STM-25 series SSD provides bad block management function with a certain number of reserved blocks. When a user data block fails, a reserved block will replace the failed block. The replacement of bad block is transparent to user. co nf id In normal operation condition, guarantees for 3 years product lifetime for half the SSD capacity sequential write per day. M em or ig ht The SSD provides Enhanced ECC algorithm which reduces error rate and enforces write endurance at the same time. There are two kinds of ECC algorithm as follows. BCH 16: it detects and corrects 16 random bits per 1024 Bytes. BCH 24: it detects and corrects 24 random bits per 1024 Bytes. Memoright STM-25 SSD complies with following standards. FCC CE RoHS Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 13 of 26 STM-25 9. Supported ATA Commands Memoright STM-25 series SSD supports ATA commends that is shown as following table. For details of the ATA command, please refer to the Draft ATA-8 Standard. Table 9 Supported ATA Commands Command Name PARAMETERS USED Code SC SN CY DR HD FT X X O X X EXECUTE DIAGNOSTICS 90h X X X O X X FLUSH CACHE E7h X X X O O X IDENTIFY DEVICE ECh X X X O X X IDLE E3h O X X X X IDLE IMMEDIATE E1h INITIALIZE DEVICE PARAMETERS 91h READ DMA C8h or C9h READ MULTIPLE C4h READ SECTOR(S) READ VERIFY SECTOR(S) O X X X O X X O X X O O X O O O O O X O O O O O X 20h or 21h O O O O O X 40h or 41h O O O O O X 10h X X X O X X 7xh X X O O O X EFh O X X O X O SET MULTIPLE MODE C6h O X X O X X SLEEP E6h X X X O X X B0h X X O O X O E2h X X X O X X STANDBY IMMEDIATE E0h X X X O X X WRITE DMA CAh or CBh O O O O O X WRITE MULTIPLE C5h O O O O O X WRITE SECTOR(S) 30h or 31h O O O O O X co RECALIBRATE SET FEATURES S.M.A.R.T. STANDBY M em or ig SEEK en tia l X nf id E5h ht CHECK POWER MODE Note: O = Valid, X = Don't care SC = Sector Count Register SN = Sector Number Register CY = Cylinder Low/High Register DR = DEVICE SELECT Bit (DEVICE/HEAD Register Bit 4) HD = HEAD SELECT Bit (DEVICE/HEAD Register Bit 3-0) FT = Features Register Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 14 of 26 STM-25 9.1 ATA Command Specifications  Check POWER MODE (E5h) The host can use this command to determine the current power management mode.  EXECUTE DIAGNOSITICS (90h) This command performs the internal diagnostic tests implemented by the drive. See ERROR register for diagnostic codes.  FLUSH CACHE (E7h) en tia l This command is used by the host to request the device to flush the write cache. If there is data in the write cache, that data shall be written to the media. The BSY bit shall remain set to one until all data has been successfully written or an error occurs. IDENTIFY DEVICE (ECh) This commands read out 512Bytes of drive parameter information. Parameter Information consists of the arrangement and value as shown in the following table. This command enables the host to receive the Identify Drive Information from the device. co nf id  M em or ig ht The following commands contain drive-specific features that may not be included in the Draft ATA-7 Standard. F/V = Fixed/variable content F = the content of the word is fixed and does not change. For removable media devices, these values may change when media is removed or changed. V = the contents of the word is variable and may change depending on the state of the device or the commands executed by the device. X = the content of the word may be fixed or variable. Table 10 IDENTIFY DEVICE returned data Word Value F/V Description General configuration bit-significant information: F 0 0040h X 15 148 0 = ATA device Retired F 7 1 = removable media device X 6 Obsolete X 5-3 Retired F 2 Reserved Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 15 of 26 STM-25 Word Value F/V Description X 1 Retired F 0 Reserved XXXXh X Number of logical cylinders 2 C837h V Specific configuration 3 00XXh X Number of logical heads 4-5 XXXXh X Retired 6 XXXXh X Number of logical sector per logical track 7-8 XXXXh V Reserved for assignment by the CompactFlash_ Association 9 000Eh X Retired 10-19 XXXXh F Serial number (20 ASCII characters) 20-21 XXXXh X Retired 22 003Fh X Obsolete 23-26 XXXXh F Firmware revision (8 ASCII characters) 27-46 XXXXh F Model number (40 ASCII characters) F 7-0 00h = Reserved F 4000h F en tia 01h = Maximum number of 1 sectors on READ/WRITE MULTIPLE commands Reserved M em or ig 48 80h nf id 8000h 8 co 47 15- ht F l 1 Capabilities F F 1514 13 Reserved for the IDENTIFY PACKET DEVICE command. 1 = Standby timer values as specified in this standard are supported 0 = Standby timer values shall be managed by the device 49 2F00h F F 12 Reserved for the IDENTIFY PACKET DEVICE command. 11 1 = IORDY supported 0 = IORDY may be supported F 10 1 = IORDY may be disabled F 9 1 = LBA supported F 8 1 = DMA supported. X 7-0 Retired Capabilities 50 4000h F 15 Shall be cleared to zero. F 14 Shall be set to one. F 132 Reserved. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 16 of 26 STM-25 Word Value F/V Description X 1 F 0 15- 51 0280h X 8 Obsolete Shall be set to one to indicate a device specific Standby timer value minimum. PIO data transfer cycle timing mode 7-0 Reserved F 153 F 2 F 1 X 0 0007h Reserved 1 = the fields reported in word 88 are valid 0 = the fields reported in word 88 are not valid 1 = the fields reported in words 70:64 are valid 0 = the fields reported in words 70:64 are not valid 1 = the fields reported in words 58:54 are valid 0 = the fields reported in words 58:54 are not valid XXXXh X Number of current cylinders 55 00XXh X Number of current heads 56 XXXXh X Number of current sector per track 57-58 XXXXh X Current capacity in sectors F ht co 54 M em or ig 53 Obsolete l X en tia 0000h nf id 52 59 0000h 15- Reserved 9 V V 60-61 XXXXh F 62 0000h X F 8 1 = Multiple sector setting is valid xxh = Setting for number of sectors that shall be transferred per interrupt on 7-0 R/W Multiple command Total number of user addressable sectors Obsolete 15- Reserved 11 63 1 = Multiword DMA mode 2 is selected V 10 V 9 V 8 F 7-3 Reserved 0007h 0 = Multiword DMA mode 2 is not selected 1 = Multiword DMA mode 1 is selected 0 = Multiword DMA mode 1 is not selected 1 = Multiword DMA mode 0 is selected 0 = Multiword DMA mode 0 is not selected Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 17 of 26 STM-25 Word Value F/V 64 0003h Description F 2 1 = Multiword DMA mode 2 and below are supported F 1 1 = Multiword DMA mode 1 and below are supported F 0 1 = Multiword DMA mode 0 is supported F F 158 Reserved 7-0 Advanced PIO modes supported 0078h F Minimum Multiword DMA transfer cycle time per word 66 0078h F Manufacturer’s recommended Multiword DMA transfer cycle time 67 0078h F Minimum PIO transfer cycle time without flow control 68 0078h F Minimum PIO transfer cycle time with IORDY flow control 69-79 0000h F Reserved (for future command overlap and queuing) en tia l 65 01FEh F 14 Reserved for ATA/ATAPI-14 F 13 Reserved for ATA/ATAPI-13 F 12 Reserved for ATA/ATAPI-12 F 11 Reserved for ATA/ATAPI-11 F 10 Reserved for ATA/ATAPI-10 F 9 Reserved for ATA/ATAPI-9 F Reserved for ATA/ATAPI-8 7 1 = supports ATA/ATAPI-7 6 1 = supports ATA/ATAPI-6 5 1 = supports ATA/ATAPI-5 4 1 = supports ATA/ATAPI-4 3 Obsolete X 2 Obsolete X 1 Obsolete F 0 Reserved F F F F 0021h ht 8 F 81 co 15 Reserved M em or ig 80 F F nf id Major version number 0000h or FFFFh = device does not report version Minor version number Command set supported. 82 0068h X 15 Obsolete F 14 1 = NOP command supported F 13 1 = READ BUFFER command supported F 12 1 = WRITE BUFFER command supported X 11 Obsolete F 10 1 = Host Protected Area feature set supported Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 18 of 26 STM-25 Word Value F/V Description F 9 1 = DEVICE RESET command supported F 8 1 = SERVICE interrupt supported F 7 1 = release interrupt supported F 6 1 = look-ahead supported F 5 1 = write cache supported F 4 F 3 1 = mandatory Power Management feature set supported F 2 1 = Removable Media feature set supported F 1 0 = Security Mode feature set unsupported F 0 1 = S.M.A.R.T. feature set supported Shall be cleared to zero to indicate that the PACKET Command feature set is not 15 Shall be cleared to zero F 14 Shall be set to one F 13- Reserved co nf id F 9 8 1 = SET MAX security extension supported F 7 Reserved F F F F F F F ht 5000h F M em or ig 83 en tia Command sets supported. l supported. 6 1 = SET FEATURES subcommand required to spinup after power-up 5 1 = Power-Up In Standby feature set supported 4 1 = Removable Media Status Notification feature set supported 3 1 = Advanced Power Management feature set supported 2 1 = CFA feature set supported 1 1 = READ/WRITE DMA QUEUED supported 0 1 = DOWNLOAD MICROCODE command supported Command set/feature supported extension. 84 4000h F 15 Shall be cleared to zero F 14 F 132 Shall be set to one Reserved F 1 1 = S.M.A.R.T. self-test supported F 0 1 = S.M.A.R.T. error logging supported Command set/feature enabled. 85 0008h X 15 Obsolete F 14 1 = NOP command enabled Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 19 of 26 STM-25 Word Value F/V Description F 13 1 = READ BUFFER command enabled F 12 1 = WRITE BUFFER command enabled X 11 Obsolete V 10 1 = Host Protected Area feature set enabled F 9 1 = DEVICE RESET command enabled V 8 1 = SERVICE interrupt enabled V 7 1 = release interrupt enabled V 6 1 = look-ahead enabled V 5 1 = write cache enabled F 4 F 3 1 = Power Management feature set enabled F 2 1 = Removable Media feature set enabled V 1 1 = Security Mode feature set enabled V 0 1 = S.M.A.R.T. feature set enabled Shall be cleared to zero to indicate that the PACKET Command feature set is 86 5000h F F V V V F 9 8 Reserved nf id ht F 15- 1 = SET MAX security extension enabled by SET MAX SET PASSWORD M em or ig F co Command set/feature enabled. en tia l not supported. 7 See Address Offset Reserved Area Boot, INCITS TR27:2001 6 1 = SET FEATURES subcommand required to spin-up after power-up 5 1 = Power-Up In Standby feature set enabled 4 1 = Removable Media Status Notification feature set enabled 3-1 1 = Advanced Power Management feature set enabled 0 1 = DOWNLOAD MICROCODE command supported Command set/feature default. 87 4000h F 15 Shall be cleared to zero F 14 Shall be set to one F 13- Reserved 2 F 1 1 = S.M.A.R.T. self-test supported F 0 1 = S.M.A.R.T. error logging supported 15- 88 203Fh 13 V 12 Reserved 1 = Ultra DMA mode 4 is selected Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 20 of 26 STM-25 Word Value F/V Description 0 = Ultra DMA mode 4 is not selected 11 V 10 V 9 1 = Ultra DMA mode 3 is selected 0 = Ultra DMA mode 3 is not selected 1 = Ultra DMA mode 2 is selected 0 = Ultra DMA mode 2 is not selected 1 = Ultra DMA mode 1 is selected 0 = Ultra DMA mode 1 is not selected 1 = Ultra DMA mode 0 is selected V 8 F 7-5 Reserved F 4 1 = Ultra DMA mode 4 and below are supported F 3 1 = Ultra DMA mode 3 and below are supported F 2 1 = Ultra DMA mode 2 and below are supported F 1 1 = Ultra DMA mode 1 and below are supported F 0 1 = Ultra DMA mode 0 is supported 0 = Ultra DMA mode 0 is not selected nf id en tia l V 0000h F Time required for security erase unit completion 90 0000h F Time required for Enhanced security erase completion 91 0000h V Current advanced power management value 92 0000h V Master Password Revision Code 93 0000h X 94-126 0000h V M em or ig ht co 89 Hardware reset result Reserved Removable Media Status Notification feature set support F 127 152 Reserved 00 = Removable Media Status Notification feature set not supported 0000h F 01 = Removable Media Status Notification feature supported 1-0 10 = Reserved 11 = Reserved Security status F 128 0001h V 159 8 Reserved Security level 0 = High, 1 = Maximum F 7-6 Reserved F 5 1 = Enhanced security erase supported V 4 1 = Security count expired V 3 1 = Security frozen Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 21 of 26 STM-25 Word Value F/V Description V 2 1 = Security locked V 1 1 = Security enabled F 0 0 = Security unsupported 129-159 0000h X Vendor specific 160-254 0000h X Reserved Integrity word 255 0000h X 15- Checksum 8 en tia l 7-0 Signature IDLE (E3h) This command causes the device to set BSY, enter the Idle mode, clear BSY and generate an interrupt. If sector count is non-zero, the automatic power down mode is enabled. If the sector count iszero, the automatic power mode is disabled.  IDLE IMMEDIATE (E1h) This command causes the device to set BSY, enter the Idle(Read) mode, clear BSY and generate an interrupt.  INITIALIZE DEVICE PARAMETERS (91h) This command enables the host to set the number of sectors per track and the number of tracks per heads.  READ DMA (C8h) Read data from sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value. A sector count of zero requests 256 sectors.  READ MULTIPLE (C4h) This command performs similarly to the Read Sectors command. Interrupts are not generated on each sector, but on the transfer of a block which contains the number of sectors defined by a Set Multiple command.  READ SECTOR(S) (20h/21h) This command reads 1 to 256 sectors as specified in the Sector Count register from sectors which is set by Sector number register. A sector count of the requests 256 sectors. The transfer beings specified in the Sector Number register. M em or ig ht co nf id  Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 22 of 26 STM-25  READ VERIFY SECTOR(S) (40h/41h) This command verifies one or more sectors on the drive by transferring data from the flash media to the data buffer in the drive and verifying that the ECC is correct. This command is identical to the Read Sectors command, except that DRQ is never set and no data is transferred to the host. RECALIBRATE (10h) The current drive performs no processing if it receives this command. It is supported for backward compatibility with previous devices.  SEEK (7xh) This command is effectively a NOP command to the device although it does perform a range check.  SET FEATURES (EFh) This command set parameter to Features register and set drive’s operation. For transfer mode, parameter is set to Sector Count register. This command is used by the host to establish or select certain features. ht Table 11 Featured register and valid operating mode co nf id en tia l  Function 02h Enable write cache 03h Set transfer mode based on value in Sector Count register. 55h Disable read look-ahead feature 82h Disable write cache AAh Enable read look-ahead feature M em or ig Value  SET MULTIPLE MODE (C6h) This command enables the device to perform READ MULTIPLE and WRITE MULTIPLE operations and establishes the block count for these commands.  SLEEP (E6h) This command causes the device to set BSY, enter the Sleep mode, clear BSY and generate an interrupt. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 23 of 26 STM-25  S.M.A.R.T. Function Set (B0h) Performs different processing required for predicting device failures, according to the subcommand specified in the Features register. If the Features register contains an unsupported value, the Aborted Command error is returned. If the S.M.A.R.T. function is disabled, any subcommand other than S.M.A.R.T. ENABLE OPERATIONS results in the Aborted Command error. STANDBY (E2h) This command causes the device to set BSY, enter the Sleep mode (which corresponds to the ATA“Standby” Mode), clear BSY and return the interrupt immediately.  STANDBY IMMEDIATE (E0h) This command causes the drive to set BSY, enter the Sleep mode (which corresponds to the ATA “Standby” Mode), clear BSY and return the interrupt immediately.  WRITE DMA (CAh) Write data to sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value.  WRITE MULTIPLE (C5h) This command is similar to the Write Sectors command. Interrupts are not presented on each sector, but on the transfer of a block which contains the number of sectors defined by Set Multiple command.  WRITE SECTOR(S) (30h/31h) Write data to a specified number of sectors (1 to 256, as specified with the Sector Count register) from the specified address. Specify “00h” to write 256 sectors. M em or ig ht co nf id en tia l  Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 24 of 26 STM-25 10. Memoright SSD Marking Information co FCC Logo WEEE Logo RoHS (pb-free) Logo Warranty Warning BSMI Logo M em or ig      ht 10.1.1 Label Content  Memoright Logo  CE Logo nf id en tia l 10.1Top View Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 25 of 26 STM-25 11. Contact Information Memoright Worldwide Headquarters General Support +886-2-2218-3789 Xindian Dist., New Taipei Fax +886-2-2218-5155 City 231, Taiwan E-mail [email protected] co DISCLAIMER OF LIABILITY nf id en tia l 9F, 535, Zhongzheng Rd, ht Memoright Corp. reserves the right to make changes to specifications and product descriptions such as but not limited M em or ig to numbers, parameters and other technical information contained herein without notice. Please contact Memoright Corp. to obtain the latest specifications. Memoright Corp. grants no warranty with respect to this datasheet, explicit or implied, and is not liable for direct or indirect damages. Some states do not grant the exclusion of incidental damages and as such this statement may not be valid in such states. The provisions of the datasheet do not convey to the purchaser of the device any license under any patent right or other intellectual property right of Memoright Corp. or others COPYRIGHT NOTICE Copyright © 2012 by Memoright Corp. All rights reserved. Information contained in this document, including but not limited to any instructions, descriptions and product specifications, is considered proprietary and confidential to Memoright Corp. and shall not be modified, used, copied, reproduced or disclosed in whole or in part, in any form or by any means, electronic or mechanical, for any purpose, without the written consent of Memoright Corp. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V01 Page 26 of 26