STM-25 Multi-Temp SATA Solid State Drive 2.5” – STM-25 Series 32 GB 1. Features
100.2 mm x 69.85 mm 9.5 mm
Totally compliant to standard SATA hard disk drive
7+15 pin (SATA power) SATA connector
Available Capacities
Supported max. to UDMA6
Supported max. to PIO mode 4.
MLC NAND Flash
ECC
nf id
Highly integrated controller for NAND Flash memory
co
32 GB (MLC NAND Flash)
l
2.5” SATA solid State Drive (SSD)
en tia
ht
Form Factor
BCH 16/24 bits ECC
M em or ig
High Performance
Up to 300 MB/s burst transfer rate in SATAII, 3 Gb/s
Sustained Read Performance: up to 173 MB/s
Sustained Write Performance: up to 45 MB/s
High Reliability
MTBF > 2,100,000 hours
Endurance: > 3 years sequential write (for a half drive’s capacity write per day)
Dynamic, static and active balanced wear-leveling strategy
Bad-Block Management
S.M.A.R.T support
Temperature Ranges
Industrial Temperature Range: -40℃ ~+85℃
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 2 of 26
STM-25 2. Contents Features...................................................................................................................................................... 2
2. 3.
Contents .................................................................................................................................................. 3 Ordering Information............................................................................................................................ 4 3.1 Part Number Decoder .......................................................................................................................... 5
4.
8.
General Description ............................................................................................................................. 6 4.1 Physical Description ................................................................................................................... 6 4.2 System Performance .................................................................................................................. 7 4.3 Environmental Specifications .................................................................................................... 7 4.4 Reliability ...................................................................................................................................... 8 4.5 Physical Dimensions................................................................................................................... 8 4.6 CHS Parameter ........................................................................................................................... 8 4.7 Drive Geometry............................................................................................................................ 8 Functional Block Diagram .................................................................................................................. 9 Physical Dimension Diagram........................................................................................................... 10 Electrical Interface .............................................................................................................................. 11 7.1 Electrical Description ................................................................................................................ 11 Feature Descriptions .......................................................................................................................... 13
9.
8.1 Wear Leveling ............................................................................................................................ 13 8.2 Bad Block Management ........................................................................................................... 13 8.3 Endurance .................................................................................................................................. 13 8.4 ECC ............................................................................................................................................. 13 8.5 Standards Compliance ............................................................................................................. 13 Supported ATA Commands ...................................................................................................................... 14
nf id
co
M em or ig
ht
5. 6. 7.
en tia
l
1.
9.1 ATA Command Specifications ................................................................................................. 15 10. Memoright SSD Marking Information.............................................................................................. 25 10.1Top View.......................................................................................................................................... 25 11. Contact Information ................................................................................................................................... 26
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 3 of 26
STM-25 3. Ordering Information The following Table 1 lists the part No. for Memoright STM-25 series SSDs. Table 1: Industrial temperature product list
Part Number MRSAJ6C032GCQ25I01
Capacity
Flash Type
Form Factor
32 GB*
MLC
2.5”
* 1 GB=1,000,000,000 Bytes
M em or ig
ht
co
nf id
en tia
l
For latest ordering information, please consult Memoright’s sales representatives or check on our website: http://www.memoright.com
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 4 of 26
STM-25 3.1 Part Number Decoder
MR S A J6C 1 2
**** C* 25 I 01 3 4 5 6 7
MR: Memoright
en tia
l
SAJ6C: STM-25 Series
Capacity
Temperature Option I: Industrial (-40℃~85℃)
M em or ig
ht
co
nf id
032G: 32 GB
01: Customized Product
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
25: 2.5” Form Factor
Flash Type: MLC
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 5 of 26
STM-25 4. General Description The Memoright STM-25 series SSD provides you ultimate performance and ultra-high reliability over traditional hard disk drive by achieving up to 173 MB/s/45 MB/s sequential read/write rate and integrated protection technologies such as bad block management, wear-leveling. The above-mentioned features made Memoright STM-25 series SSD the best solution for various consumer electronics and industrial applications. For reliability, Memeoright STM-25 series SSD integrates dynamic, static and active (inactive) balanced wear leveling technology to ensure an equal usage of the Flash memory cells to extend the SSD life time. Moreover, it provides features such as Enhanced ECC algorithm, bad block management algorithm and MTBF>2,100,000 hours to assure overall reliability.
Physical Description
M em or ig
4.1
ht
co
nf id
en tia
l
Memoright STM-25 series SSD consists solely of semiconductor devices, which means it doesn’t have any mechanical part such as platter (disk), motor and suspension as traditional hard disk drive. Its characteristics such as high performance, capacity, reliability, ruggedness, low power consumption and small form factor make it the best storage solution not only for portable computing devices such as Tablet PC and UMPC but also for industrial application with extreme environment and increased MTBF requirements. Due to Memoright STM-25 series’ SATA interface and 2.5” form factor, it is the best solution to replace traditional 2.5” HDD.
The important component of Memoright STM-25 SSD includes a Flash controller and NAND Flash memory modules. The controller works with a host system to allow data to be written to and read from the Flash memory modules through a (SATA) interface. The SSD is offered in a 2.5” form factor with a SATA connector.
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 6 of 26
STM-25 4.2
System Performance
Table 2: System Performance Table
System Performance
Max.
Unit
Data transfer Rate (SATA burst (3 Gb/s)
300
MB/s
Sustained Sequential Read Rate
32 GB*
173
MB/s
Sustained Sequential Write Rate
32 GB*
45
MB/s
4KB Random Read IOPS
32 GB*
12,000
IOPS
4KB Random Write IOPS
32 GB*
600
IOPS
*1 GB=1024 Mega Byte
4.3
Environmental Specifications
en tia
l
4.3.1 Recommended Operating Conditions Table 3: Recommended Operating Conditions
Parameter
Value -40℃ to 85℃
nf id
Industrial Operating Temperature
Temperature Gradient (℃ per hour max, non-condensing)
20℃ (operating)
Temperature Gradient (℃ per hour max, non-condensing)
30℃ (non-operating)
M em or ig
Table 4: Power Consumption
5V
ht
4.3.2 Power Consumption (*)
co
Power Supply Voltage Range
Current/Power Consumption
5V
Unit
2 (Transient)
A
Continue Read Power (Average)
<3
W
Continue Write Power (Average)
<3
W
Idle Mode Power (Average)
<800
mW
Standby Mode Power (Average)
<800
mW
Input Current (Max.)
* All values are tested under room temperature 25℃ @ 5V. The power consumption may vary depends on different platform, OS, BIOS & test tools.
4.3.3 Recommended Storage Conditions Table 5: Recommended Storage Conditions
Parameter Industrial Storage Temperature
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Value -55℃ to 95℃
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 7 of 26
STM-25 4.3.4 Shock, Vibration and Humidity Table 6: Shock, Vibration and Humidity
Parameter
Value
Humidity (non-condensing)
5%~95% (Operating)
Relative Humidity Gradient
30% per hour max
Vibration
10G (Peak, 10~2000Hz)
Shock (Operating)
50G, (11ms duration, half sine wave)
Shock (Non-Operating)
4.4
1500G, (0.5ms duration, half sine wave)
Reliability
Table 7: Reliability
Value > 2,100,000 hours (Calculation mode:
en tia
l
Parameter Mean Time Between Failures (MTBF)
Telcordia SR-332 Issue 1 Method 1, Case 1)
4.5
10 years
nf id
Data Retention
Physical Dimensions
co
Physical Dimensions Length
4.6
M em or ig
Thickness
ht
Width
Unit
100.2
mm
69.85
mm
9.5
mm
CHS Parameter
Unformatted Capacity 32 GB*
Guaranteed Sectors
Bytes per Sector
58,626,288
512
*1GB=1,000,000,000 Bytes
4.7
Drive Geometry
Capacity
Default Cylinders
Default Heads
Default Sectors
32 GB*
58161
16
63
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 8 of 26
STM-25 5. Functional Block Diagram
M em or ig
ht
co
nf id
en tia
l
Figure 1: Functional Block Diagram
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 9 of 26
STM-25 6. Physical Dimension Diagram
M em or ig
ht
co
nf id
en tia
l
Figure 2: Physical Dimension Diagram
Physical Dimensions Length Width Thickness
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Unit 100.2
mm
69.85
mm
9,5
mm
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 10 of 26
STM-25 7. Electrical Interface
7.1
Electrical Description
co
nf id
en tia
l
The drive uses the industry-standard Serial ATA interface that supports 16-bit data transfers. It supports programmed input/output (PIO) modes 0–4; Ultra DMA modes 0–6. The drive also supports the use of the IORDY signal to provide reliable high-speed data transfers. For detailed information about the Serial ATA interface, refer to the draft of AT Attachment with Packet Interface Extension (ATA/ATAPI-7), NCITS T13 1410D, subsequently referred to as the Draft ATA-7 Standard. For detailed information about the Serial ATA interface, refer to the draft of AT Attachment with Packet Interface Extension (ATA/ATAPI-7), NCITS T13 1410D, subsequently referred to as the Draft ATA-7 Standard. The connector on Memoright SATA STM-25 Series SSD is divided into a signal Segment and a power Segment. The following tables summarize the signals on the SATA interface connector. For a detailed description of these signals, refer to the Draft ATA-7 Standard. Please see following Figure and table for signal and power pin assignment.
M em or ig
ht
Figure 3 SATA pin
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 11 of 26
STM-25 Table 8 Pin Assignment and description for Signal and Power pins
Signal Name
Description
S1
Ground
Second Mate
S2
R+
+Differential Receive Signal
S3
R-
-Differential Receive Signal
S4
Ground
Second Mate
S5
T-
-Differential Transmit Signal
S6
T+
+Differential Transmit Signal
S7
Ground
Second Mate
Pin Name
Signal Name
Description
P1, P2,P3
V3.3
3.3V Power(Not used)
P4
Ground
First Mate
P5
Ground
P6
Ground
P7
V5
P8
V5
5V power
P9
V5
5V power
Ground
Second Mate
P14 P15
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Second Mate Second Mate
5V power, pre-charge, second Mate
Reserved
Reserved
Ground
First Mate
V12
12V Power(Not used)
V12
12V Power(Not used)
V12
12V Power(Not used)
M em or ig
P11 P13
en tia
nf id
co ht
P10 P12
l
Pin Name
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 12 of 26
STM-25 8. Feature Descriptions 8.1
Wear Leveling
8.2
Bad Block Management
8.3
Endurance
8.4
ECC
8.5
Standards Compliance
For extending SSD’s life time, a sophisticated wear leveling technology is important. Memoright STM-25 series provides dynamic, static (initiative) balanced wear leveling strategy. The dynamic wear leveling algorithm ensures that erase/write cycles can be evenly distributed across all flash memory block locations to prevent excessive writes to the same physical flash memory location.
en tia
l
Memorigt STM-25 series SSD provides bad block management function with a certain number of reserved blocks. When a user data block fails, a reserved block will replace the failed block. The replacement of bad block is transparent to user.
co
nf id
In normal operation condition, guarantees for 3 years product lifetime for half the SSD capacity sequential write per day.
M em or ig
ht
The SSD provides Enhanced ECC algorithm which reduces error rate and enforces write endurance at the same time. There are two kinds of ECC algorithm as follows. BCH 16: it detects and corrects 16 random bits per 1024 Bytes. BCH 24: it detects and corrects 24 random bits per 1024 Bytes.
Memoright STM-25 SSD complies with following standards. FCC CE RoHS
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 13 of 26
STM-25 9. Supported ATA Commands Memoright STM-25 series SSD supports ATA commends that is shown as following table. For details of the ATA command, please refer to the Draft ATA-8 Standard. Table 9 Supported ATA Commands
Command Name
PARAMETERS USED
Code
SC
SN
CY
DR
HD
FT
X
X
O
X
X
EXECUTE DIAGNOSTICS
90h
X
X
X
O
X
X
FLUSH CACHE
E7h
X
X
X
O
O
X
IDENTIFY DEVICE
ECh
X
X
X
O
X
X
IDLE
E3h
O
X
X
X
X
IDLE IMMEDIATE
E1h
INITIALIZE DEVICE PARAMETERS
91h
READ DMA
C8h or C9h
READ MULTIPLE
C4h
READ SECTOR(S) READ VERIFY SECTOR(S)
O
X
X
X
O
X
X
O
X
X
O
O
X
O
O
O
O
O
X
O
O
O
O
O
X
20h or 21h
O
O
O
O
O
X
40h or 41h
O
O
O
O
O
X
10h
X
X
X
O
X
X
7xh
X
X
O
O
O
X
EFh
O
X
X
O
X
O
SET MULTIPLE MODE
C6h
O
X
X
O
X
X
SLEEP
E6h
X
X
X
O
X
X
B0h
X
X
O
O
X
O
E2h
X
X
X
O
X
X
STANDBY IMMEDIATE
E0h
X
X
X
O
X
X
WRITE DMA
CAh or CBh
O
O
O
O
O
X
WRITE MULTIPLE
C5h
O
O
O
O
O
X
WRITE SECTOR(S)
30h or 31h
O
O
O
O
O
X
co
RECALIBRATE SET FEATURES
S.M.A.R.T. STANDBY
M em or ig
SEEK
en tia
l
X
nf id
E5h
ht
CHECK POWER MODE
Note: O = Valid, X = Don't care SC = Sector Count Register SN = Sector Number Register CY = Cylinder Low/High Register DR = DEVICE SELECT Bit (DEVICE/HEAD Register Bit 4) HD = HEAD SELECT Bit (DEVICE/HEAD Register Bit 3-0) FT = Features Register Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 14 of 26
STM-25 9.1
ATA Command Specifications
Check POWER MODE (E5h) The host can use this command to determine the current power management mode.
EXECUTE DIAGNOSITICS (90h) This command performs the internal diagnostic tests implemented by the drive. See ERROR register for diagnostic codes.
FLUSH CACHE (E7h)
en tia
l
This command is used by the host to request the device to flush the write cache. If there is data in the write cache, that data shall be written to the media. The BSY bit shall remain set to one until all data has been successfully written or an error occurs. IDENTIFY DEVICE (ECh) This commands read out 512Bytes of drive parameter information. Parameter Information consists of the arrangement and value as shown in the following table. This command enables the host to receive the Identify Drive Information from the device.
co
nf id
M em or ig
ht
The following commands contain drive-specific features that may not be included in the Draft ATA-7 Standard. F/V = Fixed/variable content F = the content of the word is fixed and does not change. For removable media devices, these values may change when media is removed or changed. V = the contents of the word is variable and may change depending on the state of the device or the commands executed by the device. X = the content of the word may be fixed or variable. Table 10 IDENTIFY DEVICE returned data
Word Value F/V
Description General configuration bit-significant information:
F 0
0040h
X
15 148
0 = ATA device Retired
F
7
1 = removable media device
X
6
Obsolete
X
5-3 Retired
F
2
Reserved
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 15 of 26
STM-25 Word Value F/V
Description
X
1
Retired
F
0
Reserved
XXXXh
X
Number of logical cylinders
2
C837h
V
Specific configuration
3
00XXh
X
Number of logical heads
4-5
XXXXh
X
Retired
6
XXXXh
X
Number of logical sector per logical track
7-8
XXXXh
V
Reserved for assignment by the CompactFlash_ Association
9
000Eh
X
Retired
10-19
XXXXh
F
Serial number (20 ASCII characters)
20-21
XXXXh
X
Retired
22
003Fh
X
Obsolete
23-26
XXXXh
F
Firmware revision (8 ASCII characters)
27-46
XXXXh
F
Model number (40 ASCII characters)
F
7-0 00h = Reserved
F 4000h
F
en tia
01h = Maximum number of 1 sectors on READ/WRITE MULTIPLE commands Reserved
M em or ig
48
80h
nf id
8000h
8
co
47
15-
ht
F
l
1
Capabilities
F F
1514
13
Reserved for the IDENTIFY PACKET DEVICE command. 1 = Standby timer values as specified in this standard are supported 0 = Standby timer values shall be managed by the device
49
2F00h
F F
12
Reserved for the IDENTIFY PACKET DEVICE command.
11
1 = IORDY supported 0 = IORDY may be supported
F
10
1 = IORDY may be disabled
F
9
1 = LBA supported
F
8
1 = DMA supported.
X
7-0 Retired Capabilities
50
4000h
F
15
Shall be cleared to zero.
F
14
Shall be set to one.
F
132
Reserved.
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 16 of 26
STM-25 Word Value F/V
Description
X
1
F
0 15-
51
0280h
X
8
Obsolete Shall be set to one to indicate a device specific Standby timer value minimum. PIO data transfer cycle timing mode
7-0 Reserved
F
153
F
2
F
1
X
0
0007h
Reserved 1 = the fields reported in word 88 are valid 0 = the fields reported in word 88 are not valid 1 = the fields reported in words 70:64 are valid
0 = the fields reported in words 70:64 are not valid 1 = the fields reported in words 58:54 are valid
0 = the fields reported in words 58:54 are not valid
XXXXh
X
Number of current cylinders
55
00XXh
X
Number of current heads
56
XXXXh
X
Number of current sector per track
57-58
XXXXh
X
Current capacity in sectors
F
ht
co
54
M em or ig
53
Obsolete
l
X
en tia
0000h
nf id
52
59
0000h
15- Reserved 9
V V
60-61
XXXXh
F
62
0000h
X
F
8
1 = Multiple sector setting is valid xxh = Setting for number of sectors that shall be transferred per interrupt on
7-0 R/W Multiple command
Total number of user addressable sectors Obsolete
15- Reserved 11
63
1 = Multiword DMA mode 2 is selected
V
10
V
9
V
8
F
7-3 Reserved
0007h
0 = Multiword DMA mode 2 is not selected 1 = Multiword DMA mode 1 is selected 0 = Multiword DMA mode 1 is not selected 1 = Multiword DMA mode 0 is selected 0 = Multiword DMA mode 0 is not selected
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 17 of 26
STM-25 Word Value F/V
64
0003h
Description
F
2
1 = Multiword DMA mode 2 and below are supported
F
1
1 = Multiword DMA mode 1 and below are supported
F
0
1 = Multiword DMA mode 0 is supported
F F
158
Reserved
7-0 Advanced PIO modes supported
0078h
F
Minimum Multiword DMA transfer cycle time per word
66
0078h
F
Manufacturer’s recommended Multiword DMA transfer cycle time
67
0078h
F
Minimum PIO transfer cycle time without flow control
68
0078h
F
Minimum PIO transfer cycle time with IORDY flow control
69-79
0000h
F
Reserved (for future command overlap and queuing)
en tia
l
65
01FEh
F
14 Reserved for ATA/ATAPI-14
F
13
Reserved for ATA/ATAPI-13
F
12
Reserved for ATA/ATAPI-12
F
11
Reserved for ATA/ATAPI-11
F
10
Reserved for ATA/ATAPI-10
F
9
Reserved for ATA/ATAPI-9
F
Reserved for ATA/ATAPI-8
7
1 = supports ATA/ATAPI-7
6
1 = supports ATA/ATAPI-6
5
1 = supports ATA/ATAPI-5
4
1 = supports ATA/ATAPI-4
3
Obsolete
X
2
Obsolete
X
1
Obsolete
F
0
Reserved
F F F F
0021h
ht
8
F
81
co
15 Reserved
M em or ig
80
F
F
nf id
Major version number 0000h or FFFFh = device does not report version
Minor version number Command set supported.
82
0068h
X
15 Obsolete
F
14 1 = NOP command supported
F
13 1 = READ BUFFER command supported
F
12 1 = WRITE BUFFER command supported
X
11 Obsolete
F
10 1 = Host Protected Area feature set supported
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 18 of 26
STM-25 Word Value F/V
Description
F
9
1 = DEVICE RESET command supported
F
8
1 = SERVICE interrupt supported
F
7
1 = release interrupt supported
F
6
1 = look-ahead supported
F
5
1 = write cache supported
F
4
F
3
1 = mandatory Power Management feature set supported
F
2
1 = Removable Media feature set supported
F
1
0 = Security Mode feature set unsupported
F
0
1 = S.M.A.R.T. feature set supported
Shall be cleared to zero to indicate that the PACKET Command feature set is not
15
Shall be cleared to zero
F
14
Shall be set to one
F
13- Reserved
co
nf id
F
9 8
1 = SET MAX security extension supported
F
7
Reserved
F F F F F F F
ht
5000h
F
M em or ig
83
en tia
Command sets supported.
l
supported.
6
1 = SET FEATURES subcommand required to spinup after power-up
5
1 = Power-Up In Standby feature set supported
4
1 = Removable Media Status Notification feature set supported
3
1 = Advanced Power Management feature set supported
2
1 = CFA feature set supported
1
1 = READ/WRITE DMA QUEUED supported
0
1 = DOWNLOAD MICROCODE command supported
Command set/feature supported extension.
84
4000h
F
15 Shall be cleared to zero
F
14
F
132
Shall be set to one Reserved
F
1
1 = S.M.A.R.T. self-test supported
F
0
1 = S.M.A.R.T. error logging supported
Command set/feature enabled. 85
0008h
X
15
Obsolete
F
14
1 = NOP command enabled
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 19 of 26
STM-25 Word Value F/V
Description
F
13
1 = READ BUFFER command enabled
F
12
1 = WRITE BUFFER command enabled
X
11
Obsolete
V
10
1 = Host Protected Area feature set enabled
F
9
1 = DEVICE RESET command enabled
V
8
1 = SERVICE interrupt enabled
V
7
1 = release interrupt enabled
V
6
1 = look-ahead enabled
V
5
1 = write cache enabled
F
4
F
3
1 = Power Management feature set enabled
F
2
1 = Removable Media feature set enabled
V
1
1 = Security Mode feature set enabled
V
0
1 = S.M.A.R.T. feature set enabled
Shall be cleared to zero to indicate that the PACKET Command feature set is
86
5000h
F F V V V F
9 8
Reserved
nf id
ht
F
15-
1 = SET MAX security extension enabled by SET MAX SET PASSWORD
M em or ig
F
co
Command set/feature enabled.
en tia
l
not supported.
7
See Address Offset Reserved Area Boot, INCITS TR27:2001
6
1 = SET FEATURES subcommand required to spin-up after power-up
5
1 = Power-Up In Standby feature set enabled
4
1 = Removable Media Status Notification feature set enabled
3-1 1 = Advanced Power Management feature set enabled 0
1 = DOWNLOAD MICROCODE command supported
Command set/feature default.
87
4000h
F
15
Shall be cleared to zero
F
14
Shall be set to one
F
13- Reserved 2
F
1
1 = S.M.A.R.T. self-test supported
F
0
1 = S.M.A.R.T. error logging supported
15-
88
203Fh
13
V
12
Reserved 1 = Ultra DMA mode 4 is selected
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 20 of 26
STM-25 Word Value F/V
Description 0 = Ultra DMA mode 4 is not selected 11
V
10
V
9
1 = Ultra DMA mode 3 is selected 0 = Ultra DMA mode 3 is not selected 1 = Ultra DMA mode 2 is selected 0 = Ultra DMA mode 2 is not selected 1 = Ultra DMA mode 1 is selected 0 = Ultra DMA mode 1 is not selected 1 = Ultra DMA mode 0 is selected
V
8
F
7-5 Reserved
F
4
1 = Ultra DMA mode 4 and below are supported
F
3
1 = Ultra DMA mode 3 and below are supported
F
2
1 = Ultra DMA mode 2 and below are supported
F
1
1 = Ultra DMA mode 1 and below are supported
F
0
1 = Ultra DMA mode 0 is supported
0 = Ultra DMA mode 0 is not selected
nf id
en tia
l
V
0000h
F
Time required for security erase unit completion
90
0000h
F
Time required for Enhanced security erase completion
91
0000h
V
Current advanced power management value
92
0000h
V
Master Password Revision Code
93
0000h
X
94-126
0000h
V
M em or ig
ht
co
89
Hardware reset result Reserved
Removable Media Status Notification feature set support
F 127
152
Reserved
00 = Removable Media Status Notification feature set not supported
0000h F
01 = Removable Media Status Notification feature supported 1-0 10 = Reserved 11 = Reserved Security status
F
128
0001h
V
159 8
Reserved Security level 0 = High, 1 = Maximum
F
7-6 Reserved
F
5
1 = Enhanced security erase supported
V
4
1 = Security count expired
V
3
1 = Security frozen
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 21 of 26
STM-25 Word Value F/V
Description
V
2
1 = Security locked
V
1
1 = Security enabled
F
0
0 = Security unsupported
129-159 0000h
X
Vendor specific
160-254 0000h
X
Reserved Integrity word
255
0000h
X
15- Checksum 8
en tia
l
7-0 Signature
IDLE (E3h) This command causes the device to set BSY, enter the Idle mode, clear BSY and generate an interrupt. If sector count is non-zero, the automatic power down mode is enabled. If the sector count iszero, the automatic power mode is disabled.
IDLE IMMEDIATE (E1h) This command causes the device to set BSY, enter the Idle(Read) mode, clear BSY and generate an interrupt.
INITIALIZE DEVICE PARAMETERS (91h) This command enables the host to set the number of sectors per track and the number of tracks per heads.
READ DMA (C8h) Read data from sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value. A sector count of zero requests 256 sectors.
READ MULTIPLE (C4h) This command performs similarly to the Read Sectors command. Interrupts are not generated on each sector, but on the transfer of a block which contains the number of sectors defined by a Set Multiple command.
READ SECTOR(S) (20h/21h) This command reads 1 to 256 sectors as specified in the Sector Count register from sectors which is set by Sector number register. A sector count of the requests 256 sectors. The transfer beings specified in the Sector Number register.
M em or ig
ht
co
nf id
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 22 of 26
STM-25
READ VERIFY SECTOR(S) (40h/41h) This command verifies one or more sectors on the drive by transferring data from the flash media to the data buffer in the drive and verifying that the ECC is correct. This command is identical to the Read Sectors command, except that DRQ is never set and no data is transferred to the host. RECALIBRATE (10h) The current drive performs no processing if it receives this command. It is supported for backward compatibility with previous devices.
SEEK (7xh) This command is effectively a NOP command to the device although it does perform a range check.
SET FEATURES (EFh) This command set parameter to Features register and set drive’s operation. For transfer mode, parameter is set to Sector Count register. This command is used by the host to establish or select certain features.
ht
Table 11 Featured register and valid operating mode
co
nf id
en tia
l
Function
02h
Enable write cache
03h
Set transfer mode based on value in Sector Count register.
55h
Disable read look-ahead feature
82h
Disable write cache
AAh
Enable read look-ahead feature
M em or ig
Value
SET MULTIPLE MODE (C6h) This command enables the device to perform READ MULTIPLE and WRITE MULTIPLE operations and establishes the block count for these commands.
SLEEP (E6h) This command causes the device to set BSY, enter the Sleep mode, clear BSY and generate an interrupt.
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 23 of 26
STM-25
S.M.A.R.T. Function Set (B0h) Performs different processing required for predicting device failures, according to the subcommand specified in the Features register. If the Features register contains an unsupported value, the Aborted Command error is returned. If the S.M.A.R.T. function is disabled, any subcommand other than S.M.A.R.T. ENABLE OPERATIONS results in the Aborted Command error. STANDBY (E2h) This command causes the device to set BSY, enter the Sleep mode (which corresponds to the ATA“Standby” Mode), clear BSY and return the interrupt immediately.
STANDBY IMMEDIATE (E0h) This command causes the drive to set BSY, enter the Sleep mode (which corresponds to the ATA “Standby” Mode), clear BSY and return the interrupt immediately.
WRITE DMA (CAh) Write data to sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value.
WRITE MULTIPLE (C5h) This command is similar to the Write Sectors command. Interrupts are not presented on each sector, but on the transfer of a block which contains the number of sectors defined by Set Multiple command.
WRITE SECTOR(S) (30h/31h) Write data to a specified number of sectors (1 to 256, as specified with the Sector Count register) from the specified address. Specify “00h” to write 256 sectors.
M em or ig
ht
co
nf id
en tia
l
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 24 of 26
STM-25 10. Memoright SSD Marking Information
co
FCC Logo WEEE Logo RoHS (pb-free) Logo Warranty Warning BSMI Logo
M em or ig
ht
10.1.1 Label Content Memoright Logo CE Logo
nf id
en tia
l
10.1Top View
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01
Page 25 of 26
STM-25 11. Contact Information Memoright Worldwide Headquarters General Support
+886-2-2218-3789
Xindian Dist., New Taipei
Fax
+886-2-2218-5155
City 231, Taiwan
E-mail
[email protected]
co
DISCLAIMER OF LIABILITY
nf id
en tia
l
9F, 535, Zhongzheng Rd,
ht
Memoright Corp. reserves the right to make changes to specifications and product descriptions such as but not limited
M em or ig
to numbers, parameters and other technical information contained herein without notice. Please contact Memoright Corp. to obtain the latest specifications. Memoright Corp. grants no warranty with respect to this datasheet, explicit or implied, and is not liable for direct or indirect damages. Some states do not grant the exclusion of incidental damages and as such this statement may not be valid in such states. The provisions of the datasheet do not convey to the purchaser of the device any license under any patent right or other intellectual property right of Memoright Corp. or others
COPYRIGHT NOTICE Copyright © 2012 by Memoright Corp. All rights reserved. Information contained in this document, including but not limited to any instructions, descriptions and product specifications, is considered proprietary and confidential to Memoright Corp. and shall not be modified, used, copied, reproduced or disclosed in whole or in part, in any form or by any means, electronic or mechanical, for any purpose, without the written consent of Memoright Corp.
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: V01