Preview only show first 10 pages with watermark. For full document please download

Memoright Confidential

   EMBED


Share

Transcript

l Industrial Temp SATA SSD 2.5” en tia GTR-2S M em or ig ht co nf id SATAII-3.0 Gb/s Industrial Temperature Grade Standard 2.5” SSD Revision: V03 Memoright Corp. Date: April 2014 9F,535, Zhong Zheng Rd, Xin Dian Dist., Memoright reserves the right to change products or specifications without notice. Revision: V03 New Taipei City, Taiwan Page 1 of 38 GTR-2S Industrial-Temp SATA Solid State Drive 2.5” – GTR-2S Series 32~512 GB 1. Features  2.5” SATA solid State Drive (SSD)  100.2 mm x 69.85 mm 9.5 mm  Totally compliant to standard SATA hard disk drive  7+15 pin (SATA power) SATA connector   Supported max. to UDMA6  Supported max. to PIO mode 4.  SLC NAND Flash nf id  Highly integrated controller for NAND Flash memory Security and Protection co  32~512 GB (SLC NAND Flash) en tia  l Available Capacities  AES 256 bit Encryption & Decryption Function Supported  TCG Opal SSC supported Self-Encrypting Drive (SED)  Security Erase Function Supported ht  Form Factor M em or ig  ECC  It supports Enhanced ECC algorithm for 16 bit per 512 Bytes to reduce error rate and enforce write endurance at the same time   High Performance  Up to 300 MB/s burst transfer rate in SATAII, 3 Gb/s  Sustained Read Performance: up to 205 MB/s  Sustained Write Performance: up to 200 MB/s High Reliability  MTBF  Endurance: In normal operation condition, guarantees for 5 years product lifetime for the SSD 4,000,000 hours capacity sequential write per day   Dynamic, static and active balanced wear-leveling strategy  Bad-Block Management Temperature Ranges  Industrial Temperature Range: -40 Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan ~+85 Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 2 of 38 GTR-2S 2. Contents Features...................................................................................................................................................... 2 2. 3. Contents .................................................................................................................................................. 3 Ordering Information............................................................................................................................ 4 3.1 Part Number Decoder .......................................................................................................................... 5 4. General Description ............................................................................................................................. 6 4.1 Physical Description ............................................................................................................... 6 4.2 System Performance .............................................................................................................. 7 4.3 Environmental Specifications ................................................................................................ 8 4.4 Reliability .................................................................................................................................. 9 4.5 Physical Dimensions............................................................................................................... 9 4.6 CHS Parameter ....................................................................................................................... 9 Functional Block Diagram ................................................................................................................ 10 Physical Dimension Diagram........................................................................................................... 11 Pin Assignment ................................................................................................................................... 13 7.1 Standard ................................................................................................................................. 13 7.2 Extra Pin (optional) ............................................................................................................... 14 9. nf id co Feature Descriptions .......................................................................................................................... 16 8.1 Wear Leveling ........................................................................................................................ 16 8.2 Bad Block Management ....................................................................................................... 16 8.3 Endurance .............................................................................................................................. 16 8.4 ECC ......................................................................................................................................... 16 8.5 Unrecoverable Read Errors ................................................................................................. 16 8.6 Standards Compliance ......................................................................................................... 16 Supported ATA Commands ...................................................................................................................... 17 ht 8. M em or ig 5. 6. 7. en tia l 1. 9.1 ATA Command Specifications ............................................................................................. 19 Supported TCG/Opal SSC Parameters .............................................................................................. 29 In-Drive UPS ..................................................................................................................................... 34 11.1 Introduction............................................................................................................................. 34 Scenario for Unexpected Power Loss Situation ....................................................................... 34 Operation of In-Drive UPS Technology ...................................................................................... 34 Conclusion ...................................................................................................................................... 36 10. 11. 11.2 11.3 11.1 12. Memoright SSD Marking Information.............................................................................................. 37 12.1Top View.......................................................................................................................................... 37 13. Contact Information ................................................................................................................................... 38 Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 3 of 38 GTR-2S 3. Ordering Information The following Table 1 lists the part No. for Memoright GTR-2S series SSDs. Table 1: Industrial temperature product list Part Number Capacity Flash Type Form Factor MRSAx3J032GT825I00 32 GB* SLC 2.5” MRSAx3J064GT925I00 64 GB* SLC 2.5” MRSAx3J128GT025I00 128 GB* SLC 2.5” MRSAX3J256GN525I00 256 GB* SLC 2.5” MRSAX3J512GNH25I00 512 GB* SLC 2.5” en tia l * 1 GB=1,000,000,000 Bytes For latest ordering information, please consult Memoright’s sales representatives or check on our website: M em or ig ht co nf id http://www.memoright.com Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 4 of 38 GTR-2S 3.1 Part Number Decoder MR 1 SAX3J 2 **** ** 25 I 00 3 4 5 6 7 MR: Memoright GTR-2S: SAX3J Series en tia l 00: Standard Capacity Temperature Option I: Industrial (-40 ~85 ) co nf id 032G: 32 GB 064G: 64 GB 128G: 128 GB 256G: 256 GB M em or ig ht 512G: 512 GB Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan 25: 2.5” Form Factor **:Flash Type: SLC Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 5 of 38 GTR-2S 4. General Description The Memoright GTR-2S series SSD provides you ultimate performance and ultra-high reliability en tia l over traditional hard disk drive by achieving up to 205 MB/s/200 MB/s sequential read/write rate and integrated protection technologies such as bad block management, wear-leveling. The above-mentioned features made Memoright GTR-2S series SSD the best solution for various consumer electronics and industrial applications. For enhancing the security and protection ability for Memoright GTR-2S series SSD, it integrates advanced security and protection features such as AES-256 bits encryption and decryption and TCG Opal SSC self-encrypting technologies making it the best guard for precious data with no loss of performance, especially in industrial and military fields. When TCG Opal security features are not enabled, Memoright GT-2S series SSD performs the security function by adopting ATA security command set encryption features. nf id For reliability, Memeoright GTR-2S series SSD features dynamic, static and active (inactive) balanced wear leveling technology to ensure an equal usage of the Flash memory cells to extend the SSD life time. Moreover, it provides features such as Enhanced ECC algorithm, bad block management algorithm and MTBF 4,000,000 hours to assure overall reliability. co Memoright GTR-2S series SSD consists solely of semiconductor devices, which means it doesn’t have any mechanical part such as platter (disk), motor and suspension as traditional hard disk drive. 4.1 M em or ig ht Its characteristics such as high performance, capacity, reliability, ruggedness, low power consumption and small form factor make it the best storage solution not only for military & industrial application with extreme environment and increased MTBF requirements. Due to Memoright GTR-2S series’ SATA interface and 2.5” form factor, it is the best solution to replace traditional 2.5” HDD. Physical Description The important component of Memoright GTR-2S SSD includes a Flash controller and NAND Flash memory modules. The controller works with a host system to allow data to be written to and read from the Flash memory modules through a (SATA) interface. The SSD is offered in a 2.5” form factor with a SATA connector. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 6 of 38 GTR-2S 4.2 System Performance Table 2: System Performance Table Unit Data transfer Rate (SATA burst (3 Gb/s) 300 MB/s Sustained Sequential Read Rate 32 GB 205 MB/s Sustained Sequential Write Rate 32 GB 200 MB/s 4KB Random Read IOPS 32 GB 4000 IOPS 4KB Random Write IOPS 32 GB 350 IOPS Sustained Sequential Read Rate 64 GB 205 MB/s Sustained Sequential Write Rate 64 GB 200 MB/s 4KB Random Read IOPS 64 GB 4000 IOPS 4KB Random Write IOPS 64 GB 350 IOPS Sustained Sequential Read Rate 128 GB Sustained Sequential Write Rate 128 GB 4KB Random Read IOPS 128 GB 4KB Random Write IOPS 128 GB Sustained Sequential Read Rate 256 GB Sustained Sequential Write Rate 256 GB 4KB Random Read IOPS 256 GB 4KB Random Write IOPS l Max. en tia System Performance MB/s 200 MB/s 4000 IOPS 600 IOPS 205 MB/s 200 MB/s 3500 IOPS 256 GB 250 IOPS Sustained Sequential Read Rate 512 GB 205 MB/s Sustained Sequential Write Rate 512 GB 200 MB/s 4KB Random Read IOPS 512 GB 4500 IOPS 4KB Random Write IOPS 512 GB 400 IOPS co ht M em or ig Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan nf id 205 Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 7 of 38 GTR-2S 4.3 Environmental Specifications 4.3.1 Recommended Operating Conditions Table 3: Recommended Operating Conditions Parameter Industrial Operating Temperature Value -40 to 85 Power Supply Voltage Range 5V 4.3.2 Power Consumption (*) Table 4: Power Consumption Unit 1 A Continue Read Power (Average) 2.7 W Typical Continue Read Current (Average) 500 mA Continue Write Power (Average) 4.1 W nf id Input Current (Max.) l 5V en tia Current/Power Consumption 700 mA 2 W 300 mA 2 W Typical Continue Write Current (Average) Idle Mode Power (Average) co Typical Idle Mode/Standby Current (Average) 5V. The power consumption may vary depends on different platform, OS, BIOS & test tools. M em or ig * All values are tested under room temperature 25 ht Standby Mode Power (Average) 4.3.3 Recommended Storage Conditions Table 5: Recommended Storage Conditions Parameter Industrial Storage Temperature Value -55 to 95 4.3.4 Shock, Vibration and Humidity Table 6: Shock, Vibration and Humidity Parameter Humidity (non-condensing) Vibration Shock (Operating) Shock (Non-Operating) Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Value 5%~95% (Operating) 16.4G (Peak, 10~2000Hz,x3 Axis) 50G, (11ms duration, half sine wave) 1500G, (0.5ms duration, half sine wave) Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 8 of 38 GTR-2S 4.4 Reliability Table 7: Reliability Parameter Value 4,000,000 hours (Calculation mode: Mean Time Between Failures (MTBF) Telcordia SR-332 Issue 1 Method 1, Case 1) 1 Non-Recoverable Error per 1015 bits Read Data Reliability Data Retention 4.5 10 years Physical Dimensions Physical Dimensions Unit 100.2 Width 69.85 mm 9.5 mm en tia nf id Thickness 4.6 CHS Parameter Unformatted Capacity 64 GB* 512 125,829,120 512 251,658,240 512 503,316,480 512 1,006,632,960 512 M em or ig mm Bytes per Sector 62,914,560 ht 128 GB* 512 GB* Guaranteed Sectors co 32 GB* 256 GB* l Length *1GB=1,000,000,000 Bytes Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 9 of 38 GTR-2S 5. Functional Block Diagram Figure 1: Functional Block Diagram SRAM (64KB) MicroBlaze SATA Controller Flash Controller FLASH Flash Controller 8 Channels FLASH M em or ig ht BCH ENC nf id BCH DEC co DDR2 Controller en tia l SATAII 64MB DDR2 SDRAM Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 10 of 38 GTR-2S 6. Physical Dimension Diagram M em or ig ht co nf id en tia l Figure 2: Physical Dimension Diagram (standard) Physical Dimensions Length Width Thickness Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Unit 100.2 mm 69.85 mm 9.5 mm Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 11 of 38 GTR-2S M em or ig ht co nf id en tia l Figure 3 Physical Dimension Diagram with hardware trigger (optional) Physical Dimensions Length Width Thickness Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Unit 100.2 mm 69.85 mm 9.5 mm Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 12 of 38 GTR-2S 7. Pin Assignment 7.1 Standard M em or ig ht co nf id en tia l Figure 4 SATA pin Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 13 of 38 GTR-2S 7.2 Extra Pin (optional) Erase/Destroy LED Status Indicator Signal 3 2 6 GND 4 1 5 l Write Protection M em or ig ht co nf id en tia Write Protection function: pin 3 and pin 4 must be connected. Hardware Erase Trigger signals: It can be send via a switch button connected to pin 1 and 2. LED status indicator: It can be added on pin 5 and 6. Please note polarity while connecting LED. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 14 of 38 GTR-2S Table 8 Pin Assignment and description for Signal and Power pins Signal Name Description S1 Ground Second Mate S2 R+ +Differential Receive Signal S3 R- -Differential Receive Signal S4 Ground Second Mate S5 T- -Differential Transmit Signal S6 T+ +Differential Transmit Signal S7 Ground Second Mate Pin Name Signal Name Description P1, P2,P3 V3.3 3.3V Power P4 Ground First Mate P5 Ground P6 Ground P7 V5 P8 V5 5V power P9 V5 5V power Ground Second Mate P14 P15 Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Second Mate Second Mate 5V power, pre-charge, second Mate Reserved Reserved Ground First Mate V12 12V Power(Not used) V12 12V Power(Not used) V12 12V Power(Not used) M em or ig P11 P13 en tia nf id co ht P10 P12 l Pin Name Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 15 of 38 GTR-2S 8. Feature Descriptions 8.1 Wear Leveling 8.2 Bad Block Management 8.3 Endurance 8.4 ECC 8.5 Unrecoverable Read Errors 8.6 Standards Compliance For extending SSD’s life time, a sophisticated wear leveling technology is important. Memoright GTR-2S series provides dynamic, static (initiative) balanced wear leveling strategy. The dynamic wear leveling algorithm ensures that erase/write cycles can be evenly distributed across all flash memory block locations to prevent excessive writes to the same physical flash memory location. en tia l Memorigt GTR-2S series SSD provides bad block management function with a certain number of reserved blocks. When a user data block fails, a reserved block will replace the failed block. The replacement of bad block is transparent to user. nf id In normal operation condition, guarantees for 5 years product lifetime for the SSD. ht co It supports Enhanced ECC algorithm for 16 bit per 512 Bytes to reduce error rate and enforce write endurance at the same time. M em or ig The unrecoverable read errors are less than 1 error per 1015 bits read. Memoright GTR-2S SSD complies with following standards. FCC CE RoHS Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 16 of 38 GTR-2S 9. Supported ATA Commands Memoright GTR-2S series SSD supports ATA commends that is shown as following table. For details of the ATA command, please refer to the Draft ATA-8 Standard. Table 9 Supported ATA Commands Code (hex) Command Name 10h Read Sectors 20h Write Sectors 30h Read Verify Sectors 40h Seek 70h en tia l Recalibrate Executive Device Diagnostic 90h Initialize Device Parameters 91h S.M.A.R.T nf id B0h Read Multiple Write Multiple co Set Multiple Mode Read DMA Flush Cache Write Buffer Identify Device Set Features M em or ig Read Buffer ht Write DMA C4h C5h C6h C8h CAh E4h E7h E8h ECh EFh Power Management Check Power Mode 98h, E5h Sleep E6h Standby Immediate E0h Idle Immediate 95h, E1h Standby E2h Idle 97h, E3h 48 bit addressing Read Sector (s) EXT 24h Read DMA EXT 25h Read Multiple EXT 29h Write Sector (s) EXT 34h Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 17 of 38 GTR-2S 35h Write Multiple EXT 39h Read Verify Sector (S) EXT 42h Flush CACHE EXT EAh M em or ig ht co nf id en tia l Write DMA EXT Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 18 of 38 GTR-2S 9.1 ATA Command Specifications Recalibrate (10h) When this command is issued, the GTR-2S series SSD sets BSY and waits for that the device is initialized, and then clears BSY.  Read Sector (s) (20h) This command will read from 1 to 256 sectors as specified in the Sector Count Register. A sector count of 0 (zero) requests 256 sectors. The transfer will begin at the sector specified in the Sector Number Register.  Read Sectors (s) EXT (24h) This command reads from 1 to 65,536 sectors as specified in the Sector Count register. A sector count of0000h requests 65,536 sectors. The transfer shall begin at the sector specified in the LBA Low, LBA Mid, and LBA High registers.  Read DMA EXT (25h) The Read DMA EXT command allows the host to read data using the DMA data transfer protocol. M em or ig Tab10 IDENTIFY DEVICE returned data ht co nf id en tia l   Read Multiple EXT (29h) This command reads the number of sectors specified in the Sector Count register.  Write Sector(s) (30h) This command will write from 1 to 256 sectors as specified in the Sector Count Register. A sector count of 0 (zero) will request 256 sectors. The transfer begins at the sector specified in the Sector Number Register.  Write Sector(s) EXT (34h) This command reads the number of sectors specified in the Sector Count register.  Read/Verify Sector(s) (40h) This command will verify one or more sectors by transferring data from the flash media to the data buffer and verifying the ECC is correct. The command is identical to the Read Sector(s) 20h command except that DRQ is never set and no data is transferred to the host. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 19 of 38 GTR-2S  Read Verify Sector (s) EXT (42h) This command is identical to the Read Sector(s) EXT command, except that the device shall have read the data from the media, the DRQ bit is never set to one, and no data is transferred to the host. Seek (70h) This command will cause the device performing a range check.  Execute Device Diagnostic (90h) This command performs the internal diagnostic tests implemented by the controller.  Initialize Device Parameters (91h) This command will enable the host to set the number of sectors per track and the number of heads per cylinder.  S.M.A.R.T (B0h) When this command is issued, the GTR-2S Series SSD will report the SMART data to Host.  Read Multiple (C4h) This command is similar to the Read Sector(s) -20h command. Interrupts are not generated on each sector, but on the transfer of a block that contains the number of sectors as defined by a Set Multiple Mode - C6h command.  Write Multiple (C5h) This command is similar to the Write Sector(s) - 30h command. Interrupts are not presented on each sector, but on the transfer of a block which contains the number of sectors defined by the Set Multiple Mode - C6h command.  Set Multiple Mode (C6h) This command enables the SSD to perform multiple Read and Write operations and establishes the block count for these commands.  Read DMA (C8h) When this command is issued, the GTR-2S Series SSD will prepare for receiving the data M em or ig ht co nf id en tia l  transfer from host via ultra DMA protocol. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 20 of 38 GTR-2S Write DMA (CAh) When this command is issued, the GTR-2S Series SSD will prepare for receiving the data transfer from host via ultra DMA protocol.  Standby Immediate (E0h) This command will cause the GTR-2S Series SSD to set BSY, enter the Standby Mode, clear BSY, and return the interrupt immediately.  Idle Immediate (E1h or 95h) This command will cause the drive to set BSY, enter the IDLE (READ) mode, clear BSY, and generate an interrupt.  Standby (E2h) This command is similar to Standby immediate.  Idle (E3h) This command is similar to Idle immediate.  Read Buffer (E4h) This command enables the GTR-2S Series SSD to transfer the buffer data in cache.  Check Power (E5h or 98h) This command enables the Host to check the GTR-2S Series SSD power mode.  Sleep (E6h) This command enables the Host set GTR-2S Series SSD into sleep mode.  Flush Cache (E7h) When this command is issued, the device will flush all data in cache into GTR-2S Series SSD disk to protect the data.  Write Buffer (E8h) This command enables the GTR-2S Series SSD to receive the buffer data from host into cache.  Flush CACHE EXT (EAh) This command is used by the host to request the device to flush the write cache. If there is data in the write cache, that data shall be written to the media. The BSY bit shall remain set to one M em or ig ht co nf id en tia l  Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 21 of 38 GTR-2S until all data has been successfully written or an error occurs.  Identify Device (ECh) The Identify Device command (command code ECH) transfers information about the drive to the host following power up. The data is organized as a single 512-byte block of data, whose contents are shown in Table 7 on page 20. All reserved bits or words should be set to zero. Parameters listed with an “x” are drive-specific or vary with the state of the drive. See Section 2.0 on page 3 for default parameter settings. The following commands contain drive-specific features that may not be included in the Draft ATA-7 Standard. Word en tia l Table 11 Drive-Specific features Description Configuration information: Bit 15: 0=ATA; 1=ATAPI Bit 7: removable media nf id 0 Bit 0: reserved Number of logical cylinders 2 Specific configuration 3 Number of logical heads M em or ig 4 ht 1 co Bit 6: removable Controller Value 0040h 3FFFh C837h 0010h Retired 0000h Retired 0000h Number of logical sectors per logical track 003Fh Retired 0000h Serial number: 20 ASCII characters ASCII Retired 0000h 21 Retired 0000h 22 Obsolete 0000h 23-26 Firmware revision: 8ASCII characters ASCII 27-46 Drive model number: 40 ASCII characters ASCII 5 6 7-9 10-19 20 47 (Bits 7–0) Maximum sectors per interrupt on Read multiple and Write multiple (1) 8001h 48 Reserved 0000h 49 Standard Standby timer, IORDY supported and may be disabled 2F00h 50 Capabilities 4000h 51 Retired 0000h 52 Retired 0000h Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 22 of 38 GTR-2S 53 Words 54–58, 64–70 and 88 are valid 0007h 54 Number of current logical cylinders XXXXh 55 Number of current logical heads XXXXh 56 Number of current logical sectors per logical track XXXXh Current capacity in sectors XXXXh Multiple sector setting 0101h 57-58 59 60-61 Total number of user address sectors(LBA mode) XXXX XXXXh 62 Obsolete 0000h 63 Multi-word DMA transfer(Not support) 0000h 64 Flow control PIO transfer modes supported 0003h 65 Minimum Multiword DMA transfer cycle time per word 0078h l Manufacturer’s recommended Multiword DMA transfer cycle time per en tia 66 word 0078h Minimum PIO transfer cycle time without flow control 0078h 68 Minimum PIO transfer cycle time with IORDY flow control 0078h 69-74 75 Reserved No DMA QUEUED command supports nf id 67 Reserved 80-81 ATA Ver support (ATA/ATAPI-7 T13 1532D revision 4a) 0000h 0000h 00FE 0021h ht co 76-79 0000h Command set supported M em or ig 15 0 = Obsolete 14 1 = NOP Command supported 13 1 = READ BUFFER Command supported 12 1 = WRITE BUFFER Command supported 11 1 = Obsolete 10 0 = Host Protected Area Feature Set not supported 09 0 = DEVICE RESET Command not supported 82 08 0 = SERVICE Interrupt not supported 786Bh 07 0 = RELEASE Interrupt not supported 06 1 = Look Ahead supported 05 1 = Write Cache supported 04 0 = indicate that the PACKET feature set not supported 03 1 = Power Management Feature Set supported (mandatory) 02 0 = Removable Media feature set not supported 01 1 = Security Mode Feature Set supported 00 1 = SMART Feature Set supported 83 Command set supported 15 Shall be cleared to zero Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan 5028h/5428h Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 23 of 38 GTR-2S 14 Shall be set to one 13 0 = FLUSH CACHE EXT Command not supported 12 1 = FLUSH CACHE Command supported (mandatory) 11 0 = Device Configuration Overlay feature set not supported 10 1/0 = 48-Bit Address feature set supported /not supported 09 0 = Automatic Acoustic Management feature set not supported 08 0 = SET MAX security extension not supported 07 0 = See Address Offset Reserved Area Boot, INCITS TR27:2001 06 0 = SET FEATURES subcommand not required to spin-up after power-up 05 1 = Power-Up in Standby feature set supported en tia l 04 0 = Obsolete 03 1 = Advanced Power Management feature set supported 02 0 = CFA feature set not supported 01 0 = READ/WRITE DMA QUEUED not supported nf id 00 0 = DOWNLOAD MICROCODE Command not supported 15 Shall be cleared to zero 14 Shall be set to one co Command Set/Feature Supported Extension M em or ig 12 0 = Reserved ht 13 0 = IDLE IMMEDIATE with UNLOAD FEATURE not supported 11 0 = Reserved 10:9 0 = Obsolete 08 0 = 64-Bit World Wide Name not supported 84 07 0 = Write DMA QUEUED FUA EXT Command not supported 4003h 06 0 = Write DMA FUA EXT and WRITE MULTIPLE FUA EXT commands not supported 05 0 = General Purpose Logging feature set not supported 04 0 = Streaming feature set not supported 03 0= Media Card Pass Through Command feature set not supported 02 0 = Media Serial Number not supported 01 1 = SMART Self-Test supported 00 1 = SMART Error-Logging supported Command set/feature enabled 15 0 = Obsolete 85 14 1 = NOP Command enabled 7869h 13 1 = READ BUFFER Command enabled 12 1 = WRITE BUFFER Command enabled Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 24 of 38 GTR-2S 11 1 = Obsolete 10 0 = Host Protected Area has not been established 09 0 = DEVICE RESET Command not enabled 08 0 = SERVICE Interrupt not enabled 07 0 = RELEASE Interrupt not enabled 06 1 = Look Ahead enabled 05 1 = Write Cache enabled 04 0 = indicate that the PACKET feature is not supported. 03 1 = Power Management Feature Set enabled 02 0 = Obsolete 01 0 = Security Mode Feature Set enabled en tia l 00 1 = SMART Feature Set enabled Command set/feature enabled 15 0 = Reserved 14 0 = Reserved nf id 13 0 = FLUSH CACHE EXT Command not supported 12 1 = FLUSH CACHE Command supported co 11 0 = Device Configuration Overlay not supported 10 1/0 = 48-Bit Address features set supported/not supported ht 09 0 = Automatic Acoustic Management feature set not enabled 86 M em or ig 08 0 = SET MAX security extension not enabled by SET MAX SETPASSWORD 1008h/1408h 07 0 = Reserved 06 0 = SET FEATURES subcommand required to spin-up after power-up not enabled 05 0 = Power-Up in Standby feature set not enabled 04 0 = Obsolete 03 1 = Advanced Power Management feature set enabled 02 0 = CFA feature set not supported 01 0 = READ/WRITE DMA QUEUED Command not supported 00 0 = DOWNLOAD MICROCODE Command not supported Command set/feature default 15 Shall be cleared to zero 14 Shall be set to one 87 13 1 = IDLE IMMEDIATE with UNLOAD FEATURE supported 4003h 12 0 = Reserved for Technical Report, INCITS TR-37-2004 (TLC) 11 0 = Reserved for Technical Report, INCITS TR-37-2004 (TLC) 10:9 0 = Obsolete Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 25 of 38 GTR-2S 08 0 = 64-Bit World Wide Name not supported 07 0 = WRITE DMA QUEUED FUA EXT Command not supported 06 0 = WRITE DMA FUA EXT and WRITE MULTIPLE FUA EXT commands not supported 05 0 = General Purpose Logging feature set not supported 04 0 = Obsolete 03 0 = Media Card Pass Through Command feature set not supported 02 0 = Media Serial Number is not valid 01 1 = SMART Self-Test supported 00 1 = SMART Error-Logging supported Ultra DMA modes 007Fh 89 Time required for security erase unit completion XXXXh Time required for Enhanced security erase unit completion(Not support) Current advanced power management value 92 Master Password Revision Code 93 Hardware reset result co Reserved nf id 91 94-99 en tia 90 l 88 0000h 4080h FFFEh 600Bh 0000h Maximum user LBA for 48-bit Address feature set XXXXh 104-126 Reserved 0000h 128 129-159 160 161-175 176-205 206-254 255 Removable Media Status Notification feature set support 0000h Security Status 0001h Vendor specific 0000h CFA power mode 1(Not support) 0000h Reserved 0000h Current media serial number 0000h Reserved 0000h CheckSum XXXXh M em or ig 127 ht 100-103  Set Features (EFh) This command is used by the host to establish or select certain features.  Set Features command This command controls the implementation of various features that the drive supports. When the drive receives this command, it sets BSY, checks the contents of the Features register, clears BSY and generates an interrupt. If the value in the register does not represent a feature that the drive supports, the command is aborted. Power-on default has the read look-ahead and writes caching features enabled. The acceptable values for the Features register are Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 26 of 38 GTR-2S defined as follows: Description 01h Reserved 02h Enable write cache 03h Set transfer mode based on value in Sector Count register 04h Obsolete 05h Enable advanced power management 06h Enable Power-Up In Standby feature set. 07h Power-Up In Standby feature set device spin-up 09h Reserved 0Ah Reserved 10h Reserved for Serial ATA 20h Reserved 21h en tia Reserved 31h 43h Reserved M em or ig 44h Obsolete co 42h Reserved ht 33h l Value nf id Table 12 Set Features Description Reserved Obsolete 54h Obsolete 55h Disable read look-ahead feature 5Dh Reserved 5Eh Reserved 66h Disable reverting to power-on defaults 77h Obsolete 81h Reserved 82h Disable write cache 84h Obsolete 85h Disable advanced power management 86h Disable Power-Up In Standby feature set 88h Obsolete 89h Reserved 8Ah Reserved 90h Reserved for Serial ATA 95h Reserved Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 27 of 38 GTR-2S Obsolete 9Ah Obsolete AAh Enable read look-ahead feature ABh Obsolete BBh Obsolete C2h Reserved CCh Enable reverting to power-on defaults DDh Reserved DEh Reserved E0h Obsolete F0-FFh Reserved M em or ig ht co nf id en tia l 99h Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 28 of 38 GTR-2S 10. Supported TCG/Opal SSC Parameters Property Supported Comments /Not Supported TCG Specification for Storage OPAL: TCG Storage Security Subsystem Class Spec.2.00 Revision 1.00, Feb 24,2012 TCG Storage Interface Interactions TCG Reference Spec. Spec. Version 1.02, Revision:1.00 30,Dec. 2011 TCG Core Spec.2.00 Revision 2.00, Nov. 4, 2011 OPAL SSC 1.00 (backward compatibility) Not Supported -- OPAL SSC Additional Feature Set Spec. 1.00 Revision 1.00, Feb 24, l Supported en tia Single User Mode 2012 Supported nf id PSID-Physical Presence SID Additional DataStore Table Supported Supported M em or ig GUDID (Globally Unique Serial Number) ht co SID Authority Disabled TCG Storage Protection Mechanism for secrets Modifiable CommonName Columns Supported Supported Spec. version 1.00, Committee Draft Revision 1.05 Feb9,2011 Spec. 1.00 Revision 1.00, Feb 24, 2012 SID Authority Disabled Proposal 9/26/2011 (Microsoft) Mandatory GUDID Proposal 11/03/2011 (Microsoft) Spec. version 1.00, Revision 1.07, 17 Aug, 2011 Supported Modifiable CommonName Columns Proposal 7/22/2010 (Microsoft) OPAL SSC Feature Set (Specific List) Close Session (optional) Supported Allows Tper to notify the host that a session is aborted. ALL OPAL Mandatory Features Supported -- Revert Method Supported -- Revert SP Method Supported -- Activate Method Supported -- Type Table (Not Required) Not Supported -- Active Method Within Transactions Not Supported According to OPAL, this behavior is out of the scope Revert Method Within Transactions Not Supported According to OPAL, this behavior is out of the scope Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 29 of 38 GTR-2S Revert SP Method Within Transactions Not Supported According to OPAL, this behavior is out of the scope Creation/Deletion of Tables/Rows after Not Supported Manufacturing According to OPAL, this behavior is out of the scope Restricted Command & Table (optional) Not Supported The interface control template achieves Tper control over selected interface commands to reduce the undesired side effects. Tper Feature Not Supported Flow Control ACK/NACK Support Not Supported Session Reliability Async Support Not Supported Support for asynchronous protocol en tia l Buffer Management Support with multiple commands per session COM ID Management Support Not Supported Dynamic COM ID allocation & management not supported nf id Geometry Reporting Feature 512 bytes Logical Block Size=512 Bytes ALIGN Supported OPAL 2.0 (only) 4096 Bytes Page or Descriptor size <> 0 -- 1 -- 0x1000 0x1000-0xFFFF defined for COM ID OPAL SSC V2.00 Feature Descriptor Number of COM IDs Base COM ID Number of Locking SP Admin Authorities Supported Range Crossing Behavior management 4 According to OPAL 2.0, drive should support at least 4 admin 0 If a drive receives a READ or WRITE command that spans multiple LBA ranges. Moreover, the LBA ranges are not locked, then: 1. Process the data transfer, if Range Crossing=0 2. Terminate the command with “Other invalid Command Parameter” if Range Crossing=1 Number of Locking SP User Authorities Supported 9 According to OPAL 2.0, drive should support for at least 8 users Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 30 of 38 GTR-2S Property Supported /Not Supported Behavior of C_PIN_SID PIN upon Ter Revert 0x00 Comments 0x00=The C_PiN_SID PIn value becomes the value of the C_PIN_MSID Pin column after successful invocation of revert on the admin SP’s object in the SP table Initial C_PIN_SID PIN Indicator 0x00 0x00=The initial C_PIN_SID PIN value is equal to the C_PIN_MSID PIN value 0xFF=The initial C_PIN_SID_PIN en tia l value is VU, and MAY not be equal to the C_PIN_MSID PIN value OPAL 2.0 (only) Customer-specific SID-Configurable nf id DataStore Table Feature 90 MB co Maximum total size of Datastrobe Tables bytes of all of the DataStrobe tables that the Tper supports, including the Datastrobe table defined in OPAL ht M em or ig Maximum number of DataStrobe Tables Specifies the maximum total size in SSC 2.0 9 The maximum number of the DataStrobe tables that the Tper supports, including the DataStrobe table defined in OPAL SSC 2.0 DataStrobe Table Size Alignment 10 MB -- MBR Table 128 MB -- Byte Table Access Granularity Recommended Access Granularity 8192 Tper recommends when the host invokes the set or get method on byte tables, it should be less than or equal to 8192. Mandatory Write Granularity 1 Tper enforces when the host invokes the set method on byte tables, it should be less than or equal to 8192, it should be less than or equal to Recommended Access Granularity, OPAL 2.0 (only) Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 31 of 38 GTR-2S Cryptographic Features AES Key Size 256 Bits AES Key is generated by using CTR DRBG algorithm (FIPS Compliant) Number of Ranges/Band Supported 9 (8 user definable, 1 global range) It supports 8 LBA ranges, if LBA ranges are unlocked, range cross read and write is allowed. AES Mode CBC Key Management IV Swapped Authentication data required. It complies with TCG Storage Protection Mechanisms for Secrets; Specification version 1.00, Revision en tia l 1.00, 05, March, 2012 Re-Encryption Crypto Erase Completion Time 1s -- Yes -- Supported ECB mode used only for generating nf id AES 256-Bit CBC/ECB Mode Not Supported SHA 256 Supported -- Supported -- Supported -- Supported -- co RSA2048 Signature Verification the random key by CTR DRBG CTR DRBG M em or ig Tper Communication Properties ht Cryptographic Algorithms are Certified by FIPS-197 Max Response ComPacket Size 131072 256 sectors (128K) Max Packet Size 128512 -- 131072 256 sectors (128K) 123904 -- 2 -- 1 -- Max SubPackets 1 -- Max Sessions 1 Max ComPacket Size Max Individual Token Size Max Authentications Max Packets Each session requires a set of buffers and variables Max Transaction Limit 1 Transaction are inside sessions Max Methods 1 Methods are contained in a transaction Def Session Timeout Yes The session timeout length (in milliseconds) used by the Tper by default Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 32 of 38 GTR-2S IEEE 1667 TCG Storage Silo Supported -- Probe Silo Supported -- IEEE1667 Major Version TBD According to current draft specification. Other than Probe and TCG Storage Silo IEEE1667 Minor Version Maximum P_OUT Transfer Size Not Supported -- TBD -- 131072 256 sectors (128K) Others FDE (ATA Security with Key Management) Yes Secure Firmware Download Supported -Firmware image is validated by en tia l using SHA256 and RSA2048 algorithm (FIPS-compliant, M em or ig ht co nf id certification pending) Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 33 of 38 GTR-2S 11. In-Drive UPS 11.1 Introduction en tia l For Industrial, military storage solutions or storage applications in some extreme environments such as high temperature, high pressure or high altitude, to achieve highest storage reliability is very important. For military or industrial-grade SSD, the demand for highest reliability is more important than in normal applications due to military or industrial-grade SSD usually contains mission-critical data and it will be a disaster if the data stored in it is lost or corrupted due to sudden power-loss or power-failure conditions. There are two main kinds of power-loss situation including momentary power-loss or loss of all power for an extended period of time. For an SSD, sudden power-failure condition can cause system latency or permanent data loss. To prevent data loss situation from happening in unexpected power-loss condition, Memoright’s industrial and military-grade SSDs adopt proprietary In-Drive UPS technology to assure the safety, integrity and highest reliability of mission-critical data. nf id 11.2 Scenario for Unexpected Power Loss Situation co For NAND Flash-based storage solutions, it is important for them to complete a program (write) operation to assure that the data is stored successfully within the NAND Flash. For MLC NAND Flash which stores two logical pages of data within one physical page, it is more important to M em or ig ht prevent the power-loss condition from happening. An unexpected power-loss condition can stop ongoing erase and write operation for the SSD resulting in loss of mission-critical data or more serious disasters especially in industrial or military applications. 11.3 Operation of In-Drive UPS Technology For the current flash bandwidth and SATA interface bandwidth, most algorithms will implement the on-board buffer to increase the host IO throughput rate. Once the SSD encounters unexpected power failure, the SSD will lose power and the data in the controller and buffer will disappear immediately. The impact for that will cause the user data loss and bad block generated. Memoright GTR/GTR-II series SSD adopts a proprietary “Power-Cycle Endurance Technology” with In-Drive UPS to solve this issue. When GTR/GTR-II series SSD encounters a sudden power-loss condition, the patented In-Drive UPS technology will properly flush data back to flashes without any data loss or bad block generated. When input voltage drops below a certain low threshold, the controller of the SSD will be notified and will lock the drive to maintain data integrity. Last transmitted data will be flushed back due to the In-Drive UPS. Each of the GTR/GTR-II series SSDs will pass hundreds of power-cycles during the mass production step to ensure the normal operation of the In-Drive UPS technology. The operation steps and functional block diagram of the In-Drive UPS technology are shown as following. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 34 of 38 GTR-2S Figure 5 Functional Block Diagram of the In-Drive UPS Host Interface Data Device ESD Protection* OVP/OCP* Power Management UPS* Controller Processor l Temperature Sensor* ht co Memoright Data Protection Power Sensor* en tia Cache* nf id System Area User Area M em or ig Figure 6 Functional Block Diagram of the In-Drive UPS Power input voltage drop below lower threshold System switch to alternative power source UPS Lock Sufficient power to maintain operation Flush Idle The processor verifes power level to start flushing back data. The ARM processor is notified by dedicated sensor and lock the drive. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 35 of 38 GTR-2S 11.1 Conclusion For industrial or military level storage solutions, power-loss or power-failure prevention mechanism is critical for assuring highest data storage integrity and reliability especially for NAND Flash-based M em or ig ht co nf id en tia l storage solutions. Memoright’s patented In-Drive UPS technology that can lock the drive once the power-loss situation is happening and then flush back data when the input voltage is back to normal level differentiates Memoright’s SSD from other competitors and makes it the best storage solution for a variety of fields such as industrial, military and other specific application markets. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 36 of 38 GTR-2S 12. Memoright SSD Marking Information ht M em or ig 10.1.1 Label Content  Memoright Logo  CE Logo  FCC Logo  WEEE Logo  RoHS (pb-free) Logo  Warranty Warning  BSMI Logo co nf id en tia l 12.1Top View Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 37 of 38 GTR-2S 13. Contact Information Memoright Worldwide Headquarters General Support +886-2-2218-3789 Xindian Dist., New Taipei Fax +886-2-2218-5155 City 231, Taiwan E-mail [email protected] co DISCLAIMER OF LIABILITY nf id en tia l 9F, 535, Zhongzheng Rd, ht Memoright Corp. reserves the right to make changes to specifications and product descriptions such as but not limited M em or ig to numbers, parameters and other technical information contained herein without notice. Please contact Memoright Corp. to obtain the latest specifications. Memoright Corp. grants no warranty with respect to this datasheet, explicit or implied, and is not liable for direct or indirect damages. Some states do not grant the exclusion of incidental damages and as such this statement may not be valid in such states. The provisions of the datasheet do not convey to the purchaser of the device any license under any patent right or other intellectual property right of Memoright Corp. or others COPYRIGHT NOTICE Copyright 2014 by Memoright Corp. All rights reserved. Information contained in this document, including but not limited to any instructions, descriptions and product specifications, is considered proprietary and confidential to Memoright Corp. and shall not be modified, used, copied, reproduced or disclosed in whole or in part, in any form or by any means, electronic or mechanical, for any purpose, without the written consent of Memoright Corp. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: V03 Page 38 of 38