Transcript
ia
l
Multi-Temp SATA SSD 2.5”
on fid en t
STM-25
SATAII-3.0 Gb/s up to UDMA6/PIO4 Commercial & Semi-industrial
M
em
or
ig
ht c
Temperature Grade
Revision: 1.0 Memoright Corp.
Date: August 9F,535, Zhong2012 Zheng Rd, Xin Dian Dist.,
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
New Taipei City, Taiwan QuadLife-18 series datasheet 20120816.doc
Page 1 of 27
STM-25
Multi-Temp SATA Solid State Drive 2.5” – STM-25 Series 16Gbytes~512Gbytes 1. Features Form Factor
2.5” SATA solid State Drive (SSD)
100.2 mm x 69.85 mm 9.5 mm
Totally compliant to standard SATA hard disk drive
7+15 pin (SATA power) SATA connector
Highly integrated controller for NAND Flash memory Supported max. to UDMA6
Supported max. to PIO mode 4.
MLC NAND Flash
ECC
BCH 16/24 bits ECC
ig
ht c
High Performance
or
16~512 GB (MLC NAND Flash)
Up to 600 MB/s burst transfer rate in SATAIII, 6 GB/sec
Sustained Read Performance: up to 240 MB/s
Sustained Write Performance: up to 200 MB/s
High Reliability
em
on fid en t
Available Capacities
M
ia
l
MTBF > 2,100,000 hours
Endurance: > 3 years sequential write (for a half drive’s capacity write per day)
Dynamic, static and active balanced wear-leveling strategy
Bad-Block Management
S.M.A.R.T support
Temperature Ranges
℃ Commercial Temperature Range: 0℃ ℃ ~+70℃ Semi-industrial Temperature Range: -20℃ ℃ ~+70℃ ℃
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 2 of 27
STM-25 2. Contents Features...................................................................................................................................................... 2
2. 3.
Contents .................................................................................................................................................. 3 Ordering Information............................................................................................................................ 4 3.1 Part Number Decoder .......................................................................................................................... 5
4.
General Description.............................................................................................................................. 6 4.1 Physical Description.................................................................................................................... 6 4.2 System Performance .................................................................................................................. 7 4.3 Environmental Specifications .................................................................................................... 8 4.4 Reliability ...................................................................................................................................... 9 4.5 Physical Dimensions................................................................................................................... 9 4.6 CHS Parameter ........................................................................................................................... 9 4.7 Drive Geometry............................................................................................................................ 9 Functional Block Diagram ................................................................................................................ 10
6. 7.
M
9.
em
or
ig
8.
Physical Dimension Diagram........................................................................................................... 11 Electrical Interface .............................................................................................................................. 12 7.1 Electrical Description ................................................................................................................ 12 Feature Descriptions .......................................................................................................................... 14 8.1 Wear Leveling ............................................................................................................................ 14 8.2 Bad Block Management ........................................................................................................... 14 8.3 Endurance .................................................................................................................................. 14 8.4 ECC ............................................................................................................................................. 14 8.5 Unrecoverable Read Errors ..................................................................................................... 14 8.6 Standards Compliance ............................................................................................................. 14 Supported ATA Commands ...................................................................................................................... 15
ht c
5.
on fid en t
ia
l
1.
9.1 ATA Command Specifications ................................................................................................. 16 10. Memoright SSD Marking Information.............................................................................................. 26 10.1Top View.......................................................................................................................................... 26 11. Contact Information ................................................................................................................................... 27
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 3 of 27
STM-25 3. Ordering Information The following Table 1 lists the part No. for Memoright STM-25 series SSDs. Table 1: Commercial temperature product list
Flash Type
Form Factor
MRSAJ6C016GC125C00
16 GB*
MLC
2.5”
MRSAJ6C032GC125C00
32 GB*
MLC
2.5”
MRSAJ6C064GC125C00
64 GB*
MLC
2.5”
MRSAJ6C128GC225C00
128 GB*
MLC
2.5”
MRSAJ6C256GCA25C00
256 GB*
MLC
2.5”
MRSAJ6C256GC325C00
256 GB*
MLC
2.5”
MRSAJ6C512GC725C00
512 GB*
MLC
MRSAJ6C512GCH25C00
512 GB*
Table 2: Semi-industrial temperature product list
Capacity
ia
2.5”
MLC
2.5”
Flash Type
Form Factor
MLC
2.5”
16 GB*
MRSAJ6C032GC125S00
32 GB*
MLC
2.5”
MRSAJ6C064GC125S00
64 GB*
MLC
2.5”
MRSAJ6C128GC225S00
128 GB*
MLC
2.5”
MRSAJ6C256GCA25S00
256 GB*
MLC
2.5”
256 GB*
MLC
2.5”
512 GB*
MLC
2.5”
512 GB*
MLC
2.5”
MRSAJ6C512GC725S00
or
M
MRSAJ6C512GCH25S00
em
MRSAJ6C256GC325S00
ht c
MRSAJ6C016GC125S00
ig
Part Number
l
Capacity
on fid en t
Part Number
* 1 GB=1,000,000,000 Bytes
For latest ordering information, please consult Memoright’s sales representatives or check on our website: http://www.memoright.com
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 4 of 27
STM-25 3.1 Part Number Decoder
MR S A J6C 2 1
**** C* 25 C 00 3 4 5 6 7
00: Standard
MR: Memoright
SAJ6C: STM-25 Series
on fid en t
ia
l
25: 2.5” Form Factor
Capacity
Temperature Option C: Commercial (0℃~70℃) S: Semi-industrial (-20℃~70℃)
M
em
or
ig
ht c
016G: 16 GB 032G: 32 GB 064G: 64 GB 128G: 128 GB 256G: 256 GB 512G: 512 GB
Flash Type: MLC
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 5 of 27
STM-25 4. General Description The Memoright STM-25 series SSD provides you ultimate performance and ultra-high reliability over traditional hard disk drive by achieving up to 240 MB/s/200 MB/s sequential read/write rate and integrated protection technologies such as bad block management, wear-leveling. The above-mentioned features made Memoright STM-25 series SSD the best solution for various consumer electronics and industrial applications. For reliability, Memeoright STM-25 series SSD integrates dynamic, static and active (inactive) balanced wear leveling technology to ensure an equal usage of the Flash memory cells to extend the SSD life time. Moreover, it provides features such as Enhanced ECC algorithm, bad block management algorithm and MTBF> >2,100,000 hours to assure overall reliability.
Physical Description
or
ig
4.1
ht c
on fid en t
ia
l
Memoright STM-25 series SSD consists solely of semiconductor devices, which means it doesn’t have any mechanical part such as platter (disk), motor and suspension as traditional hard disk drive. Its characteristics such as high performance, capacity, reliability, ruggedness, low power consumption and small form factor make it the best storage solution not only for portable computing devices such as Tablet PC and UMPC but also for industrial application with extreme environment and increased MTBF requirements. Due to Memoright STM-25 series’ SATA interface and 2.5” form factor, it is the best solution to replace traditional 2.5” HDD.
M
em
The important component of Memoright STM-25 SSD includes a Flash controller and NAND Flash memory modules. The controller works with a host system to allow data to be written to and read from the Flash memory modules through a (SATA) interface. The SSD is offered in a 2.5” form factor with a SATA connector.
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
QuadLife-18 series datasheet 20120816.doc
Revision: 1.0
Page 6 of 27
STM-25 4.2
System Performance
Table 3: System Performance Table
Unit
Data transfer Rate (SATA burst (3 GB/s)
300
MB/s
Sustained Sequential Read Rate
16 GB
100*
MB/s
Sustained Sequential Read Rate
32 GB
173*
MB/s
Sustained Sequential Read Rate
64 GB
210*
MB/s
Sustained Sequential Read Rate
128 GB
230*
MB/s
Sustained Sequential Read Rate
256 GB
240*
MB/s
Sustained Sequential Read Rate
512 GB
230*
MB/s
Sustained Sequential Write Rate
16 GB
25*
MB/s
Sustained Sequential Write Rate
32 GB
45*
MB/s
Sustained Sequential Write Rate
64 GB
100*
Sustained Sequential Write Rate
128 GB
Sustained Sequential Write Rate
256 GB
Sustained Sequential Write Rate
512 GB
4KB Random Read IOPS
16 GB
4KB Random Read IOPS
32 GB
4KB Random Read IOPS
l
Max.
MB/s MB/s
200*
MB/s
200*
MB/s
4,500
IOPS
12,000
IOPS
64 GB
4,400
IOPS
4KB Random Read IOPS
128 GB
11,000
IOPS
4KB Random Read IOPS
256 GB
10,000
IOPS
512 GB
9,000
IOPS
16 GB
120
IOPS
4KB Random Write IOPS
32 GB
600
IOPS
4KB Random Write IOPS
64 GB
750
IOPS
4KB Random Write IOPS
128 GB
600
IOPS
4KB Random Write IOPS
256 GB
2,700
IOPS
4KB Random Write IOPS
512 GB
4,200
IOPS
M
em
4KB Random Write IOPS
or
4KB Random Read IOPS
ht c
120*
ig
on fid en t
ia
System Performance
*1 GB=1024 Mega Bytes
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 7 of 27
STM-25 4.3
Environmental Specifications
4.3.1 Recommended Operating Conditions Table 4: Recommended Operating Conditions
Parameter
Value 0℃ to 70℃
Commercial Operating Temperature
-20℃ to 70℃
Semi-industrial Operating Temperature Temperature Gradient (℃ per hour max, non-condensing)
20℃ (operating)
Temperature Gradient (℃ per hour max, non-condensing)
30℃ (non-operating)
Power Supply Voltage Range
ia
l
3.3V DC ± 5%
on fid en t
4.3.2 Power Consumption (*) Table 5: Power Consumption
Current/Power Consumption Input Current (Max.) Continue Read Power (Average)
Unit
2 (Transient) <3
A W
<3
W
<800
mW
<800
mW
ht c
Continue Write Power (Average)
3.3V
Idle Mode Power (Average) Standby Mode Power (Average)
or
ig
* All values are tested under room temperature 25℃ @ 5V. The power consumption may vary depends on different platform, OS, BIOS & test tools.
em
4.3.3 Recommended Storage Conditions Table 6: Recommended Storage Conditions
M
Parameter Commercial & Semi-industrial Storage Temperature
Value -40℃ to 85℃
4.3.4 Shock, Vibration and Humidity Table 7: Shock, Vibration and Humidity
Parameter
Value
Humidity (non-condensing)
5%~95% (Operating)
Relative Humidity Gradient
30% per hour max
Vibration Shock (Operating) Shock (Non-Operating)
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
10G (Peak, 10~2000Hz) 50G, (0.5ms duration, half sine wave) 1500G, (0.5ms duration, half sine wave)
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 8 of 27
STM-25
4.4
Reliability
Table 8: Reliability
Parameter Mean Time Between Failures (MTBF)
Value > 2,100,000 hours (Calculation mode:
Data Reliability
Telcordia SR-332 Issue 1 Method 1, Case 1) <1 Non-Recoverable Error per 1014 bits Read
Data Retention
10 years
ia
l
Physical Dimensions
4.5
on fid en t
Physical Dimensions Length Width Thickness
CHS Parameter
Unformatted Capacity
or em
512 GB*
M
256 GB*
69.85
mm
9.5
mm
Bytes per Sector
29,323,728
512
58,626,288
512
117,231,408
512
234,441,648
512
468,862,128
512
937,703088
512
ig
32 GB* 128 GB*
mm
Guaranteed Sectors
16 GB* 64 GB*
100.5
ht c
4.6
Unit
*1GB=1,000,000,000 Bytes
4.7
Drive Geometry
Capacity
Default Cylinders
Default Heads
Default Sectors
16 GB*
29091
16
63
32 GB*
58161
16
63
64 GB*
116301
16
63
128 GB*
232581
16
63
256 GB*
465141
16
63
512 GB*
TBD
TBD
TBD
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 9 of 27
STM-25 5. Functional Block Diagram
M
em
or
ig
ht c
on fid en t
ia
l
Figure 1: Functional Block Diagram
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 10 of 27
STM-25 6. Physical Dimension Diagram
Width Thickness
M
Length
em
Physical Dimensions
or
ig
ht c
on fid en t
ia
l
Figure 2: Physical Dimension Diagram
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Unit 100.2
mm
69.85
mm
9,5
mm
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 11 of 27
STM-25 7. Electrical Interface
7.1
Electrical Description
The drive uses the industry-standard Serial ATA interface that supports 1616-bit data transfers. It supports programmed input/output (PIO) modes 0–4; Ultra DMA modes 0–6. The drive also supports the use of the IORDY signal to provide reliable high-speed data transfers. For detailed information about the Serial ATA interface, refer to the draft of AT Attachment with Packet Interface Extension (ATA/ATAPI-7), NCITS T13 1410D, subsequently referred to as the Draft ATA-7 Standard. For detailed information about the Serial ATA interface, refer to the draft of
ia
l
AT Attachment with Packet Interface Extension (ATA/ATAPI-7), NCITS T13 1410D, subsequently referred to as the Draft ATA-7 Standard. The connector on Memoright SATA STM-25 Series SSD is
on fid en t
divided into a signal Segment and a power Segment. The following tables summarize the signals on the SATA interface connector. For a detailed description of these signals, refer to the Draft ATA-7 Standard. Please see following Figure and table for for signal and power pin assignment.
M
em
or
ig
ht c
Figure 3 SATA pin
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 12 of 27
STM-25 Table 9 Pin Assignment and description for Signal and Power pins
Signal Name
Description
S1
Ground
Second Mate
S2
R+
+Differential Receive Signal
S3
R-
-Differential Receive Signal
S4
Ground
Second Mate
S5
T-
-Differential Transmit Signal
S6
T+
+Differential Transmit Signal
S7
Ground
Second Mate
Pin Name
Signal Name
Description
P1, P2,P3
V3.3
3.3V Power
P4
Ground
First Mate
P5
Ground
P6
Ground
Second Mate
P7
V5
5V power, pre-charge, second Mate
P8
V5
5V power
P9
V5
5V power
ig
P11 P12
Second Mate
Ground
Second Mate
Reserved
Reserved
Ground
First Mate
V12
12V Power(Not used)
V12
12V Power(Not used)
V12
12V Power(Not used)
M
em
or
P13 P15
ia
on fid en t
ht c
P10
P14
l
Pin Name
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 13 of 27
STM-25 8. Feature Descriptions 8.1
Wear Leveling
For extending SSD’s life time, a sophisticated wear leveling technology is important. Memoright STM-25 series provides dynamic, static (initiative) balanced wear leveling strategy. The dynamic wear leveling algorithm ensures that erase/write cycles can be evenly distributed across all flash memory block locations to prevent excessive writes to the same physical flash memory location.
8.2
Bad Block Management
Memorigt STM-25 series SSD provides bad block management function with a certain number of reserved blocks. When a user data block fails, a reserved block will replace the failed block. The
ia
Endurance
on fid en t
8.3
l
replacement of bad block is transparent to user.
The endurance of the SSD is > 3years sequential write (for a half drive’s capacity write per day).
8.4
ECC
Unrecoverable Read Errors
ig
8.5
ht c
The SSD provides Enhanced ECC algorithm which reduces error rate and enforces write endurance at the same time. The ECC recovery is up to 55bits correctable per 512-bytes sector.
Standards Compliance
em
8.6
or
The unrecoverable read errors are less than 1 error per 1014 bits read.
M
Memoright STM-25 SSD complies with following standards. FCC CE RoHS
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 14 of 27
STM-25 9. Supported ATA Commands Memoright STM-25 series SSD supports ATA commends that is shown as following table. For details of the ATA command, please refer to the Draft ATA-8 Standard. Table 10 Supported ATA Commands
Command Name
Code
PARAMETERS USED SC
SN
CY
DR
HD
FT
E5h
X
X
X
O
X
X
EXECUTE DIAGNOSTICS
90h
X
X
X
O
X
X
FLUSH CACHE
E7h
X
X
X
O
O
X
IDENTIFY DEVICE
ECh
X
X
X
O
X
X
IDLE
E3h
O
X
X
O
X
X
IDLE IMMEDIATE
E1h
X
X
O
X
X
INITIALIZE DEVICE PARAMETERS
91h
O
X
X
O
O
X
READ DMA
C8h or C9h
O
O
O
O
O
X
READ MULTIPLE
C4h
O
O
O
O
O
X
READ SECTOR(S)
20h or 21h
O
O
O
O
O
X
READ VERIFY SECTOR(S)
40h or 41h
O
O
O
O
O
X
10h
X
X
X
O
X
X
7xh
X
X
O
O
O
X
EFh
O
X
X
O
X
O
C6h
O
X
X
O
X
X
E6h
X
X
X
O
X
X
B0h
X
X
O
O
X
O
E2h
X
X
X
O
X
X
STANDBY IMMEDIATE
E0h
X
X
X
O
X
X
WRITE DMA
CAh or CBh
O
O
O
O
O
X
WRITE MULTIPLE
C5h
O
O
O
O
O
X
WRITE SECTOR(S)
30h or 31h
O
O
O
O
O
X
SEEK
ig
SET FEATURES
em
SLEEP
M
S.M.A.R.T. STANDBY
or
SET MULTIPLE MODE
ia X
on fid en t
ht c
RECALIBRATE
l
CHECK POWER MODE
Note: O = Valid, X = Don't care SC = Sector Count Register SN = Sector Number Register CY = Cylinder Low/High Register DR = DEVICE SELECT Bit (DEVICE/HEAD Register Bit 4) HD = HEAD SELECT Bit (DEVICE/HEAD Register Bit 3-0) FT = Features Register Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 15 of 27
STM-25 9.1
ATA Command Specifications
•
Check POWER MODE (E5h) The host can use this command to determine the current power management mode.
•
EXECUTE DIAGNOSITICS (90h) This command performs the internal diagnostic tests implemented by the drive. See ERROR register for diagnostic codes.
•
FLUSH CACHE (E7h)
on fid en t
ia
l
This command is used by the host to request the device to flush the write cache. If there is data in the write cache, that data shall be written to the media. The BSY bit shall remain set to one until all data has been successfully written or an error occurs. •
ht c
IDENTIFY DEVICE (ECh) This commands read out 512Bytes of drive parameter information. Parameter Information consists of the arrangement and value as shown in the following table. This command enables the host to receive the Identify Drive Information from the device.
M
em
or
ig
The following commands contain drive-specific features that may not be included in the Draft ATA-7 Standard. F/V = Fixed/variable content F = the content of the word is fixed and does not change. For removable media devices, these values may change when media is removed or changed. V = the contents of the word is variable and may change depending on the state of the device or the commands executed by the device. X = the content of the word may be fixed or variable. Table 11 IDENTIFY DEVICE returned data
Word Value F/V
Description General configuration bit-significant information:
F
15
0 = ATA device
140
0040h
X
Retired 8
F
7
1 = removable media device
X
6
Obsolete
X
5-3 Retired
F
2
Reserved
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 16 of 27
STM-25 Word Value F/V
Description
X
1
Retired
F
0
Reserved
XXXXh
X
Number of logical cylinders
2
C837h
V
Specific configuration
3
00XXh
X
Number of logical heads
4-5
XXXXh
X
Retired
6
XXXXh
X
Number of logical sector per logical track
7-8
XXXXh
V
Reserved for assignment by the CompactFlash_ Association
9
000Eh
X
Retired
10-19
XXXXh
F
Serial number (20 ASCII characters)
20-21
XXXXh
X
Retired
22
003Fh
X
Obsolete
23-26
XXXXh
F
Firmware revision (8 ASCII characters)
27-46
XXXXh
F
Model number (40 ASCII characters)
on fid en t
ia
l
1
15F
80h 8
8000h 7-0 00h = Reserved
F 48
4000h
F
ht c
F
01h = Maximum number of 1 sectors on READ/WRITE MULTIPLE commands Reserved
ig
47
or
Capabilities 15-
Reserved for the IDENTIFY PACKET DEVICE command. 14
F
13
em
F
1 = Standby timer values as specified in this standard are supported
49
M
0 = Standby timer values shall be managed by the device
F
12
Reserved for the IDENTIFY PACKET DEVICE command.
F
11
1 = IORDY supported
2F00h 0 = IORDY may be supported F
10
1 = IORDY may be disabled
F
9
1 = LBA supported
F
8
1 = DMA supported.
X
7-0 Retired Capabilities
50
4000h
F
15
Shall be cleared to zero.
F
14
Shall be set to one.
13F
Reserved. 2
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 17 of 27
STM-25 Word Value F/V
Description
X
1
F
0
Obsolete Shall be set to one to indicate a device specific Standby timer value minimum.
15PIO data transfer cycle timing mode 51
0280h
X
8 7-0 Reserved
52
0000h
X
Obsolete 15-
F
Reserved 3 1 = the fields reported in word 88 are valid
F
2 0 = the fields reported in word 88 are not valid 1 = the fields reported in words 70:64 are valid
F
1
on fid en t
0 = the fields reported in words 70:64 are not valid
l
0007h
ia
53
1 = the fields reported in words 58:54 are valid X
0
0 = the fields reported in words 58:54 are not valid XXXXh
X
Number of current cylinders
55
00XXh
X
Number of current heads
56
XXXXh
X
Number of current sector per track
57-58
XXXXh
X
Current capacity in sectors
15- Reserved
or
9 0000h V
8
1 = Multiple sector setting is valid
em
59
ig
F
ht c
54
xxh = Setting for number of sectors that shall be transferred per interrupt on V 60-61
XXXXh
F
62
0000h
X
F
M
7-0 R/W Multiple command Total number of user addressable sectors Obsolete
15- Reserved 11 1 = Multiword DMA mode 2 is selected
V
10 0 = Multiword DMA mode 2 is not selected
63
0007h
1 = Multiword DMA mode 1 is selected V
9 0 = Multiword DMA mode 1 is not selected 1 = Multiword DMA mode 0 is selected
V
8 0 = Multiword DMA mode 0 is not selected
F
7-3 Reserved
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 18 of 27
STM-25 Word Value F/V
Description
F
2
1 = Multiword DMA mode 2 and below are supported
F
1
1 = Multiword DMA mode 1 and below are supported
F
0
1 = Multiword DMA mode 0 is supported
15F 64
Reserved 8
0003h F
7-0 Advanced PIO modes supported
0078h
F
Minimum Multiword DMA transfer cycle time per word
66
0078h
F
Manufacturer’s recommended Multiword DMA transfer cycle time
67
0078h
F
Minimum PIO transfer cycle time without flow control
68
0078h
F
Minimum PIO transfer cycle time with IORDY flow control
69-79
0000h
F
Reserved (for future command overlap and queuing)
ia
l
65
81
0021h
14 Reserved for ATA/ATAPI-14
F
13
Reserved for ATA/ATAPI-13
F
12
Reserved for ATA/ATAPI-12
F
11
Reserved for ATA/ATAPI-11
F
10
Reserved for ATA/ATAPI-10
F
9
Reserved for ATA/ATAPI-9
F
8
Reserved for ATA/ATAPI-8
F
7
1 = supports ATA/ATAPI-7
F
6
1 = supports ATA/ATAPI-6
F
5
1 = supports ATA/ATAPI-5
F
4
1 = supports ATA/ATAPI-4
F
3
Obsolete
X
2
Obsolete
X
1
Obsolete
F
0
Reserved
F
or
ig
ht c
F
em
01FEh
15 Reserved
M
80
F
on fid en t
Major version number 0000h or FFFFh = device does not report version
Minor version number Command set supported.
82
0068h
X
15 Obsolete
F
14 1 = NOP command supported
F
13 1 = READ BUFFER command supported
F
12 1 = WRITE BUFFER command supported
X
11 Obsolete
F
10 1 = Host Protected Area feature set supported
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 19 of 27
STM-25 Word Value F/V
Description
F
9
1 = DEVICE RESET command supported
F
8
1 = SERVICE interrupt supported
F
7
1 = release interrupt supported
F
6
1 = look-ahead supported
F
5
1 = write cache supported
F
4
Shall be cleared to zero to indicate that the PACKET Command feature set is not supported. 3
1 = mandatory Power Management feature set supported
F
2
1 = Removable Media feature set supported
F
1
0 = Security Mode feature set unsupported
F
0
1 = S.M.A.R.T. feature set supported
F
15
Shall be cleared to zero
F
14
Shall be set to one
F
13- Reserved
ia
1 = SET MAX security extension supported
F
7
Reserved
F
6
1 = SET FEATURES subcommand required to spinup after power-up
F
5
1 = Power-Up In Standby feature set supported
F
4
1 = Removable Media Status Notification feature set supported
F
3
1 = Advanced Power Management feature set supported
F
2
1 = CFA feature set supported
F
1
1 = READ/WRITE DMA QUEUED supported
F
0
1 = DOWNLOAD MICROCODE command supported
or
ig
8
em
5000h
F
M
83
ht c
9
on fid en t
Command sets supported.
l
F
Command set/feature supported extension.
84
F
15 Shall be cleared to zero
F
14
4000h
Shall be set to one
13F
Reserved 2
F
1
1 = S.M.A.R.T. self-test supported
F
0
1 = S.M.A.R.T. error logging supported
Command set/feature enabled. 85
0008h
X
15
Obsolete
F
14
1 = NOP command enabled
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 20 of 27
STM-25 Word Value F/V
Description
F
13
1 = READ BUFFER command enabled
F
12
1 = WRITE BUFFER command enabled
X
11
Obsolete
V
10
1 = Host Protected Area feature set enabled
F
9
1 = DEVICE RESET command enabled
V
8
1 = SERVICE interrupt enabled
V
7
1 = release interrupt enabled
V
6
1 = look-ahead enabled
V
5
1 = write cache enabled
F
4
Shall be cleared to zero to indicate that the PACKET Command feature set is
3
1 = Power Management feature set enabled
F
2
1 = Removable Media feature set enabled
V
1
1 = Security Mode feature set enabled
V
0
1 = S.M.A.R.T. feature set enabled
Command set/feature enabled. 15Reserved
ht c
F 9 8
1 = SET MAX security extension enabled by SET MAX SET PASSWORD
F
7
See Address Offset Reserved Area Boot, INCITS TR27:2001
F
6
1 = SET FEATURES subcommand required to spin-up after power-up
V
5
1 = Power-Up In Standby feature set enabled
V
4
1 = Removable Media Status Notification feature set enabled
V
3-1 1 = Advanced Power Management feature set enabled
F
0
ig
F
em
or
5000h
M
86
on fid en t
F
ia
l
not supported.
1 = DOWNLOAD MICROCODE command supported
Command set/feature default.
87
F
15
Shall be cleared to zero
F
14
Shall be set to one
F
13- Reserved
4000h 2 F
1
1 = S.M.A.R.T. self-test supported
F
0
1 = S.M.A.R.T. error logging supported
15-
Reserved 88
13
203Fh V
12
1 = Ultra DMA mode 4 is selected
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 21 of 27
STM-25 Word Value F/V
Description 0 = Ultra DMA mode 4 is not selected 1 = Ultra DMA mode 3 is selected
V
11 0 = Ultra DMA mode 3 is not selected 1 = Ultra DMA mode 2 is selected
V
10 0 = Ultra DMA mode 2 is not selected 1 = Ultra DMA mode 1 is selected
V
9 0 = Ultra DMA mode 1 is not selected 1 = Ultra DMA mode 0 is selected
V
8
F
4
1 = Ultra DMA mode 4 and below are supported
F
3
1 = Ultra DMA mode 3 and below are supported
F
2
1 = Ultra DMA mode 2 and below are supported
F
1
1 = Ultra DMA mode 1 and below are supported
F
0
1 = Ultra DMA mode 0 is supported
ia
7-5 Reserved
on fid en t
F
l
0 = Ultra DMA mode 0 is not selected
0000h
F
Time required for security erase unit completion
90
0000h
F
Time required for Enhanced security erase completion
91
0000h
V
Current advanced power management value
92
0000h
V
Master Password Revision Code
93
0000h
X
Hardware reset result
94-126
0000h
V
Reserved
or
ig
ht c
89
15F
Reserved
M
2 127
em
Removable Media Status Notification feature set support
00 = Removable Media Status Notification feature set not supported
0000h
01 = Removable Media Status Notification feature supported F 1-0 10 = Reserved 11 = Reserved Security status 15F
Reserved 9
V 128
8
Security level 0 = High, 1 = Maximum
0001h F
7-6 Reserved
F
5
1 = Enhanced security erase supported
V
4
1 = Security count expired
V
3
1 = Security frozen
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 22 of 27
STM-25 Word Value F/V
Description
V
2
1 = Security locked
V
1
1 = Security enabled
F
0
0 = Security unsupported
129-159 0000h
X
Vendor specific
160-254 0000h
X
Reserved Integrity word
255
15- Checksum 0000h
X
8
ia
l
7-0 Signature
IDLE (E3h) This command causes the device to set BSY, enter the Idle mode, clear BSY and generate an interrupt. If sector count is non-zero, the automatic power down mode is enabled. If the sector count iszero, the automatic power mode is disabled.
•
IDLE IMMEDIATE (E1h) This command causes the device to set BSY, enter the Idle(Read) mode, clear BSY and generate an interrupt.
•
INITIALIZE DEVICE PARAMETERS (91h) This command enables the host to set the number of sectors per track and the number of tracks per heads.
•
READ DMA (C8h) Read data from sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value. A sector count of zero requests 256 sectors.
•
READ MULTIPLE (C4h) This command performs similarly to the Read Sectors command. Interrupts are not generated on each sector, but on the transfer of a block which contains the number of sectors defined by a Set Multiple command.
•
READ SECTOR(S) (20h/21h) This command reads 1 to 256 sectors as specified in the Sector Count register from sectors which is set by Sector number register. A sector count of the requests 256 sectors. The transfer beings specified in the Sector Number register.
M
em
or
ig
ht c
on fid en t
•
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 23 of 27
STM-25 READ VERIFY SECTOR(S) (40h/41h) This command verifies one or more sectors on the drive by transferring data from the flash media to the data buffer in the drive and verifying that the ECC is correct. This command is identical to the Read Sectors command, except that DRQ is never set and no data is transferred to the host.
•
RECALIBRATE (10h) The current drive performs no processing if it receives this command. It is supported for backward compatibility with previous devices.
•
SEEK (7xh) This command is effectively a NOP command to the device although it does perform a range check.
•
SET FEATURES (EFh) This command set parameter to Features register and set drive’s operation. For transfer mode,
on fid en t
ia
l
•
Table 12 Featured register and valid operating mode
ht c
parameter is set to Sector Count register. This command is used by the host to establish or select certain features.
Function
02h
Enable write cache
03h
Set transfer mode based on value in Sector Count register.
55h
Disable read look-ahead feature
82h
Disable write cache
AAh
Enable read look-ahead feature
M
em
or
ig
Value
•
SET MULTIPLE MODE (C6h) This command enables the device to perform READ MULTIPLE and WRITE MULTIPLE operations and establishes the block count for these commands.
•
SLEEP (E6h) This command causes the device to set BSY, enter the Sleep mode, clear BSY and generate an interrupt.
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 24 of 27
STM-25 S.M.A.R.T. Function Set (B0h) Performs different processing required for predicting device failures, according to the subcommand specified in the Features register. If the Features register contains an unsupported value, the Aborted Command error is returned. If the S.M.A.R.T. function is disabled, any subcommand other than S.M.A.R.T. ENABLE OPERATIONS results in the Aborted Command error.
•
STANDBY (E2h) This command causes the device to set BSY, enter the Sleep mode (which corresponds to the ATA“Standby” Mode), clear BSY and return the interrupt immediately.
•
STANDBY IMMEDIATE (E0h) This command causes the drive to set BSY, enter the Sleep mode (which corresponds to the ATA “Standby” Mode), clear BSY and return the interrupt immediately.
•
WRITE DMA (CAh) Write data to sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value.
•
WRITE MULTIPLE (C5h) This command is similar to the Write Sectors command. Interrupts are not presented on each sector, but on the transfer of a block which contains the number of sectors defined by Set Multiple command.
•
WRITE SECTOR(S) (30h/31h) Write data to a specified number of sectors (1 to 256, as specified with the Sector Count register) from the specified address. Specify “00h” to write 256 sectors.
M
em
or
ig
ht c
on fid en t
ia
l
•
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 25 of 27
STM-25 10. Memoright SSD Marking Information
ht c ig or
M
em
10.1.1 Label Content Memoright Logo CE Logo FCC Logo WEEE Logo RoHS (pb-free) Logo Warranty Warning BSMI Logo
on fid en t
ia
l
10.1Top View
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 26 of 27
STM-25 11. Contact Information Memoright Worldwide Headquarters General Support
+886-2-2218-3789
Xindian Dist., New Taipei
Fax
+886-2-2218-5155
City 231, Taiwan
E-mail
[email protected]
on fid en t
ia
l
9F, 535, Zhongzheng Rd,
ht c
DISCLAIMER OF LIABILITY
Memoright Corp. reserves the right to make changes to specifications and product descriptions such as but not limited
ig
to numbers, parameters and other technical information contained herein without notice. Please contact Memoright
or
Corp. to obtain the latest specifications. Memoright Corp. grants no warranty with respect to this datasheet, explicit or implied, and is not liable for direct or indirect damages. Some states do not grant the exclusion of incidental damages
em
and as such this statement may not be valid in such states. The provisions of the datasheet do not convey to the
others
M
purchaser of the device any license under any patent right or other intellectual property right of Memoright Corp. or
COPYRIGHT NOTICE Copyright © 2012 by Memoright Corp. All rights reserved. Information contained in this document, including but not limited to any instructions, descriptions and product specifications, is considered proprietary and confidential to Memoright Corp. and shall not be modified, used, copied, reproduced or disclosed in whole or in part, in any form or by any means, electronic or mechanical, for any purpose, without the written consent of Memoright Corp.
Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan
Memoright reserves the right to change products or specifications without notice.
Revision: 1.0
Page 27 of 27