Preview only show first 10 pages with watermark. For full document please download

Memoright Stm-25 Series Datasheet 20120829

   EMBED


Share

Transcript

ia l Multi-Temp SATA SSD 2.5” on fid en t STM-25 SATAII-3.0 Gb/s up to UDMA6/PIO4 Commercial & Semi-industrial M em or ig ht c Temperature Grade Revision: 1.0 Memoright Corp. Date: August 9F,535, Zhong2012 Zheng Rd, Xin Dian Dist., Memoright reserves the right to change products or specifications without notice. Revision: 1.0 New Taipei City, Taiwan QuadLife-18 series datasheet 20120816.doc Page 1 of 27 STM-25 Multi-Temp SATA Solid State Drive 2.5” – STM-25 Series 16Gbytes~512Gbytes 1. Features Form Factor  2.5” SATA solid State Drive (SSD)  100.2 mm x 69.85 mm 9.5 mm  Totally compliant to standard SATA hard disk drive  7+15 pin (SATA power) SATA connector  Highly integrated controller for NAND Flash memory Supported max. to UDMA6  Supported max. to PIO mode 4.  MLC NAND Flash ECC   BCH 16/24 bits ECC ig   ht c  High Performance or  16~512 GB (MLC NAND Flash)  Up to 600 MB/s burst transfer rate in SATAIII, 6 GB/sec  Sustained Read Performance: up to 240 MB/s  Sustained Write Performance: up to 200 MB/s High Reliability em  on fid en t Available Capacities M  ia l   MTBF > 2,100,000 hours  Endurance: > 3 years sequential write (for a half drive’s capacity write per day)  Dynamic, static and active balanced wear-leveling strategy  Bad-Block Management  S.M.A.R.T support Temperature Ranges   ℃ Commercial Temperature Range: 0℃ ℃ ~+70℃ Semi-industrial Temperature Range: -20℃ ℃ ~+70℃ ℃ Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 2 of 27 STM-25 2. Contents Features...................................................................................................................................................... 2 2. 3. Contents .................................................................................................................................................. 3 Ordering Information............................................................................................................................ 4 3.1 Part Number Decoder .......................................................................................................................... 5 4. General Description.............................................................................................................................. 6 4.1 Physical Description.................................................................................................................... 6 4.2 System Performance .................................................................................................................. 7 4.3 Environmental Specifications .................................................................................................... 8 4.4 Reliability ...................................................................................................................................... 9 4.5 Physical Dimensions................................................................................................................... 9 4.6 CHS Parameter ........................................................................................................................... 9 4.7 Drive Geometry............................................................................................................................ 9 Functional Block Diagram ................................................................................................................ 10 6. 7. M 9. em or ig 8. Physical Dimension Diagram........................................................................................................... 11 Electrical Interface .............................................................................................................................. 12 7.1 Electrical Description ................................................................................................................ 12 Feature Descriptions .......................................................................................................................... 14 8.1 Wear Leveling ............................................................................................................................ 14 8.2 Bad Block Management ........................................................................................................... 14 8.3 Endurance .................................................................................................................................. 14 8.4 ECC ............................................................................................................................................. 14 8.5 Unrecoverable Read Errors ..................................................................................................... 14 8.6 Standards Compliance ............................................................................................................. 14 Supported ATA Commands ...................................................................................................................... 15 ht c 5. on fid en t ia l 1. 9.1 ATA Command Specifications ................................................................................................. 16 10. Memoright SSD Marking Information.............................................................................................. 26 10.1Top View.......................................................................................................................................... 26 11. Contact Information ................................................................................................................................... 27 Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 3 of 27 STM-25 3. Ordering Information The following Table 1 lists the part No. for Memoright STM-25 series SSDs. Table 1: Commercial temperature product list Flash Type Form Factor MRSAJ6C016GC125C00 16 GB* MLC 2.5” MRSAJ6C032GC125C00 32 GB* MLC 2.5” MRSAJ6C064GC125C00 64 GB* MLC 2.5” MRSAJ6C128GC225C00 128 GB* MLC 2.5” MRSAJ6C256GCA25C00 256 GB* MLC 2.5” MRSAJ6C256GC325C00 256 GB* MLC 2.5” MRSAJ6C512GC725C00 512 GB* MLC MRSAJ6C512GCH25C00 512 GB* Table 2: Semi-industrial temperature product list Capacity ia 2.5” MLC 2.5” Flash Type Form Factor MLC 2.5” 16 GB* MRSAJ6C032GC125S00 32 GB* MLC 2.5” MRSAJ6C064GC125S00 64 GB* MLC 2.5” MRSAJ6C128GC225S00 128 GB* MLC 2.5” MRSAJ6C256GCA25S00 256 GB* MLC 2.5” 256 GB* MLC 2.5” 512 GB* MLC 2.5” 512 GB* MLC 2.5” MRSAJ6C512GC725S00 or M MRSAJ6C512GCH25S00 em MRSAJ6C256GC325S00 ht c MRSAJ6C016GC125S00 ig Part Number l Capacity on fid en t Part Number * 1 GB=1,000,000,000 Bytes For latest ordering information, please consult Memoright’s sales representatives or check on our website: http://www.memoright.com Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 4 of 27 STM-25 3.1 Part Number Decoder MR S A J6C 2 1 **** C* 25 C 00 3 4 5 6 7 00: Standard MR: Memoright SAJ6C: STM-25 Series on fid en t ia l 25: 2.5” Form Factor Capacity Temperature Option C: Commercial (0℃~70℃) S: Semi-industrial (-20℃~70℃) M em or ig ht c 016G: 16 GB 032G: 32 GB 064G: 64 GB 128G: 128 GB 256G: 256 GB 512G: 512 GB Flash Type: MLC Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 5 of 27 STM-25 4. General Description The Memoright STM-25 series SSD provides you ultimate performance and ultra-high reliability over traditional hard disk drive by achieving up to 240 MB/s/200 MB/s sequential read/write rate and integrated protection technologies such as bad block management, wear-leveling. The above-mentioned features made Memoright STM-25 series SSD the best solution for various consumer electronics and industrial applications. For reliability, Memeoright STM-25 series SSD integrates dynamic, static and active (inactive) balanced wear leveling technology to ensure an equal usage of the Flash memory cells to extend the SSD life time. Moreover, it provides features such as Enhanced ECC algorithm, bad block management algorithm and MTBF> >2,100,000 hours to assure overall reliability. Physical Description or ig 4.1 ht c on fid en t ia l Memoright STM-25 series SSD consists solely of semiconductor devices, which means it doesn’t have any mechanical part such as platter (disk), motor and suspension as traditional hard disk drive. Its characteristics such as high performance, capacity, reliability, ruggedness, low power consumption and small form factor make it the best storage solution not only for portable computing devices such as Tablet PC and UMPC but also for industrial application with extreme environment and increased MTBF requirements. Due to Memoright STM-25 series’ SATA interface and 2.5” form factor, it is the best solution to replace traditional 2.5” HDD. M em The important component of Memoright STM-25 SSD includes a Flash controller and NAND Flash memory modules. The controller works with a host system to allow data to be written to and read from the Flash memory modules through a (SATA) interface. The SSD is offered in a 2.5” form factor with a SATA connector. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. QuadLife-18 series datasheet 20120816.doc Revision: 1.0 Page 6 of 27 STM-25 4.2 System Performance Table 3: System Performance Table Unit Data transfer Rate (SATA burst (3 GB/s) 300 MB/s Sustained Sequential Read Rate 16 GB 100* MB/s Sustained Sequential Read Rate 32 GB 173* MB/s Sustained Sequential Read Rate 64 GB 210* MB/s Sustained Sequential Read Rate 128 GB 230* MB/s Sustained Sequential Read Rate 256 GB 240* MB/s Sustained Sequential Read Rate 512 GB 230* MB/s Sustained Sequential Write Rate 16 GB 25* MB/s Sustained Sequential Write Rate 32 GB 45* MB/s Sustained Sequential Write Rate 64 GB 100* Sustained Sequential Write Rate 128 GB Sustained Sequential Write Rate 256 GB Sustained Sequential Write Rate 512 GB 4KB Random Read IOPS 16 GB 4KB Random Read IOPS 32 GB 4KB Random Read IOPS l Max. MB/s MB/s 200* MB/s 200* MB/s 4,500 IOPS 12,000 IOPS 64 GB 4,400 IOPS 4KB Random Read IOPS 128 GB 11,000 IOPS 4KB Random Read IOPS 256 GB 10,000 IOPS 512 GB 9,000 IOPS 16 GB 120 IOPS 4KB Random Write IOPS 32 GB 600 IOPS 4KB Random Write IOPS 64 GB 750 IOPS 4KB Random Write IOPS 128 GB 600 IOPS 4KB Random Write IOPS 256 GB 2,700 IOPS 4KB Random Write IOPS 512 GB 4,200 IOPS M em 4KB Random Write IOPS or 4KB Random Read IOPS ht c 120* ig on fid en t ia System Performance *1 GB=1024 Mega Bytes Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 7 of 27 STM-25 4.3 Environmental Specifications 4.3.1 Recommended Operating Conditions Table 4: Recommended Operating Conditions Parameter Value 0℃ to 70℃ Commercial Operating Temperature -20℃ to 70℃ Semi-industrial Operating Temperature Temperature Gradient (℃ per hour max, non-condensing) 20℃ (operating) Temperature Gradient (℃ per hour max, non-condensing) 30℃ (non-operating) Power Supply Voltage Range ia l 3.3V DC ± 5% on fid en t 4.3.2 Power Consumption (*) Table 5: Power Consumption Current/Power Consumption Input Current (Max.) Continue Read Power (Average) Unit 2 (Transient) <3 A W <3 W <800 mW <800 mW ht c Continue Write Power (Average) 3.3V Idle Mode Power (Average) Standby Mode Power (Average) or ig * All values are tested under room temperature 25℃ @ 5V. The power consumption may vary depends on different platform, OS, BIOS & test tools. em 4.3.3 Recommended Storage Conditions Table 6: Recommended Storage Conditions M Parameter Commercial & Semi-industrial Storage Temperature Value -40℃ to 85℃ 4.3.4 Shock, Vibration and Humidity Table 7: Shock, Vibration and Humidity Parameter Value Humidity (non-condensing) 5%~95% (Operating) Relative Humidity Gradient 30% per hour max Vibration Shock (Operating) Shock (Non-Operating) Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan 10G (Peak, 10~2000Hz) 50G, (0.5ms duration, half sine wave) 1500G, (0.5ms duration, half sine wave) Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 8 of 27 STM-25 4.4 Reliability Table 8: Reliability Parameter Mean Time Between Failures (MTBF) Value > 2,100,000 hours (Calculation mode: Data Reliability Telcordia SR-332 Issue 1 Method 1, Case 1) <1 Non-Recoverable Error per 1014 bits Read Data Retention 10 years ia l Physical Dimensions 4.5 on fid en t Physical Dimensions Length Width Thickness CHS Parameter Unformatted Capacity or em 512 GB* M 256 GB* 69.85 mm 9.5 mm Bytes per Sector 29,323,728 512 58,626,288 512 117,231,408 512 234,441,648 512 468,862,128 512 937,703088 512 ig 32 GB* 128 GB* mm Guaranteed Sectors 16 GB* 64 GB* 100.5 ht c 4.6 Unit *1GB=1,000,000,000 Bytes 4.7 Drive Geometry Capacity Default Cylinders Default Heads Default Sectors 16 GB* 29091 16 63 32 GB* 58161 16 63 64 GB* 116301 16 63 128 GB* 232581 16 63 256 GB* 465141 16 63 512 GB* TBD TBD TBD Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 9 of 27 STM-25 5. Functional Block Diagram M em or ig ht c on fid en t ia l Figure 1: Functional Block Diagram Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 10 of 27 STM-25 6. Physical Dimension Diagram Width Thickness M Length em Physical Dimensions or ig ht c on fid en t ia l Figure 2: Physical Dimension Diagram Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Unit 100.2 mm 69.85 mm 9,5 mm Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 11 of 27 STM-25 7. Electrical Interface 7.1 Electrical Description The drive uses the industry-standard Serial ATA interface that supports 1616-bit data transfers. It supports programmed input/output (PIO) modes 0–4; Ultra DMA modes 0–6. The drive also supports the use of the IORDY signal to provide reliable high-speed data transfers. For detailed information about the Serial ATA interface, refer to the draft of AT Attachment with Packet Interface Extension (ATA/ATAPI-7), NCITS T13 1410D, subsequently referred to as the Draft ATA-7 Standard. For detailed information about the Serial ATA interface, refer to the draft of ia l AT Attachment with Packet Interface Extension (ATA/ATAPI-7), NCITS T13 1410D, subsequently referred to as the Draft ATA-7 Standard. The connector on Memoright SATA STM-25 Series SSD is on fid en t divided into a signal Segment and a power Segment. The following tables summarize the signals on the SATA interface connector. For a detailed description of these signals, refer to the Draft ATA-7 Standard. Please see following Figure and table for for signal and power pin assignment. M em or ig ht c Figure 3 SATA pin Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 12 of 27 STM-25 Table 9 Pin Assignment and description for Signal and Power pins Signal Name Description S1 Ground Second Mate S2 R+ +Differential Receive Signal S3 R- -Differential Receive Signal S4 Ground Second Mate S5 T- -Differential Transmit Signal S6 T+ +Differential Transmit Signal S7 Ground Second Mate Pin Name Signal Name Description P1, P2,P3 V3.3 3.3V Power P4 Ground First Mate P5 Ground P6 Ground Second Mate P7 V5 5V power, pre-charge, second Mate P8 V5 5V power P9 V5 5V power ig P11 P12 Second Mate Ground Second Mate Reserved Reserved Ground First Mate V12 12V Power(Not used) V12 12V Power(Not used) V12 12V Power(Not used) M em or P13 P15 ia on fid en t ht c P10 P14 l Pin Name Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 13 of 27 STM-25 8. Feature Descriptions 8.1 Wear Leveling For extending SSD’s life time, a sophisticated wear leveling technology is important. Memoright STM-25 series provides dynamic, static (initiative) balanced wear leveling strategy. The dynamic wear leveling algorithm ensures that erase/write cycles can be evenly distributed across all flash memory block locations to prevent excessive writes to the same physical flash memory location. 8.2 Bad Block Management Memorigt STM-25 series SSD provides bad block management function with a certain number of reserved blocks. When a user data block fails, a reserved block will replace the failed block. The ia Endurance on fid en t 8.3 l replacement of bad block is transparent to user. The endurance of the SSD is > 3years sequential write (for a half drive’s capacity write per day). 8.4 ECC Unrecoverable Read Errors ig 8.5 ht c The SSD provides Enhanced ECC algorithm which reduces error rate and enforces write endurance at the same time. The ECC recovery is up to 55bits correctable per 512-bytes sector. Standards Compliance em 8.6 or The unrecoverable read errors are less than 1 error per 1014 bits read. M Memoright STM-25 SSD complies with following standards. FCC CE RoHS Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 14 of 27 STM-25 9. Supported ATA Commands Memoright STM-25 series SSD supports ATA commends that is shown as following table. For details of the ATA command, please refer to the Draft ATA-8 Standard. Table 10 Supported ATA Commands Command Name Code PARAMETERS USED SC SN CY DR HD FT E5h X X X O X X EXECUTE DIAGNOSTICS 90h X X X O X X FLUSH CACHE E7h X X X O O X IDENTIFY DEVICE ECh X X X O X X IDLE E3h O X X O X X IDLE IMMEDIATE E1h X X O X X INITIALIZE DEVICE PARAMETERS 91h O X X O O X READ DMA C8h or C9h O O O O O X READ MULTIPLE C4h O O O O O X READ SECTOR(S) 20h or 21h O O O O O X READ VERIFY SECTOR(S) 40h or 41h O O O O O X 10h X X X O X X 7xh X X O O O X EFh O X X O X O C6h O X X O X X E6h X X X O X X B0h X X O O X O E2h X X X O X X STANDBY IMMEDIATE E0h X X X O X X WRITE DMA CAh or CBh O O O O O X WRITE MULTIPLE C5h O O O O O X WRITE SECTOR(S) 30h or 31h O O O O O X SEEK ig SET FEATURES em SLEEP M S.M.A.R.T. STANDBY or SET MULTIPLE MODE ia X on fid en t ht c RECALIBRATE l CHECK POWER MODE Note: O = Valid, X = Don't care SC = Sector Count Register SN = Sector Number Register CY = Cylinder Low/High Register DR = DEVICE SELECT Bit (DEVICE/HEAD Register Bit 4) HD = HEAD SELECT Bit (DEVICE/HEAD Register Bit 3-0) FT = Features Register Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 15 of 27 STM-25 9.1 ATA Command Specifications • Check POWER MODE (E5h) The host can use this command to determine the current power management mode. • EXECUTE DIAGNOSITICS (90h) This command performs the internal diagnostic tests implemented by the drive. See ERROR register for diagnostic codes. • FLUSH CACHE (E7h) on fid en t ia l This command is used by the host to request the device to flush the write cache. If there is data in the write cache, that data shall be written to the media. The BSY bit shall remain set to one until all data has been successfully written or an error occurs. • ht c IDENTIFY DEVICE (ECh) This commands read out 512Bytes of drive parameter information. Parameter Information consists of the arrangement and value as shown in the following table. This command enables the host to receive the Identify Drive Information from the device. M em or ig The following commands contain drive-specific features that may not be included in the Draft ATA-7 Standard. F/V = Fixed/variable content F = the content of the word is fixed and does not change. For removable media devices, these values may change when media is removed or changed. V = the contents of the word is variable and may change depending on the state of the device or the commands executed by the device. X = the content of the word may be fixed or variable. Table 11 IDENTIFY DEVICE returned data Word Value F/V Description General configuration bit-significant information: F 15 0 = ATA device 140 0040h X Retired 8 F 7 1 = removable media device X 6 Obsolete X 5-3 Retired F 2 Reserved Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 16 of 27 STM-25 Word Value F/V Description X 1 Retired F 0 Reserved XXXXh X Number of logical cylinders 2 C837h V Specific configuration 3 00XXh X Number of logical heads 4-5 XXXXh X Retired 6 XXXXh X Number of logical sector per logical track 7-8 XXXXh V Reserved for assignment by the CompactFlash_ Association 9 000Eh X Retired 10-19 XXXXh F Serial number (20 ASCII characters) 20-21 XXXXh X Retired 22 003Fh X Obsolete 23-26 XXXXh F Firmware revision (8 ASCII characters) 27-46 XXXXh F Model number (40 ASCII characters) on fid en t ia l 1 15F 80h 8 8000h 7-0 00h = Reserved F 48 4000h F ht c F 01h = Maximum number of 1 sectors on READ/WRITE MULTIPLE commands Reserved ig 47 or Capabilities 15- Reserved for the IDENTIFY PACKET DEVICE command. 14 F 13 em F 1 = Standby timer values as specified in this standard are supported 49 M 0 = Standby timer values shall be managed by the device F 12 Reserved for the IDENTIFY PACKET DEVICE command. F 11 1 = IORDY supported 2F00h 0 = IORDY may be supported F 10 1 = IORDY may be disabled F 9 1 = LBA supported F 8 1 = DMA supported. X 7-0 Retired Capabilities 50 4000h F 15 Shall be cleared to zero. F 14 Shall be set to one. 13F Reserved. 2 Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 17 of 27 STM-25 Word Value F/V Description X 1 F 0 Obsolete Shall be set to one to indicate a device specific Standby timer value minimum. 15PIO data transfer cycle timing mode 51 0280h X 8 7-0 Reserved 52 0000h X Obsolete 15- F Reserved 3 1 = the fields reported in word 88 are valid F 2 0 = the fields reported in word 88 are not valid 1 = the fields reported in words 70:64 are valid F 1 on fid en t 0 = the fields reported in words 70:64 are not valid l 0007h ia 53 1 = the fields reported in words 58:54 are valid X 0 0 = the fields reported in words 58:54 are not valid XXXXh X Number of current cylinders 55 00XXh X Number of current heads 56 XXXXh X Number of current sector per track 57-58 XXXXh X Current capacity in sectors 15- Reserved or 9 0000h V 8 1 = Multiple sector setting is valid em 59 ig F ht c 54 xxh = Setting for number of sectors that shall be transferred per interrupt on V 60-61 XXXXh F 62 0000h X F M 7-0 R/W Multiple command Total number of user addressable sectors Obsolete 15- Reserved 11 1 = Multiword DMA mode 2 is selected V 10 0 = Multiword DMA mode 2 is not selected 63 0007h 1 = Multiword DMA mode 1 is selected V 9 0 = Multiword DMA mode 1 is not selected 1 = Multiword DMA mode 0 is selected V 8 0 = Multiword DMA mode 0 is not selected F 7-3 Reserved Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 18 of 27 STM-25 Word Value F/V Description F 2 1 = Multiword DMA mode 2 and below are supported F 1 1 = Multiword DMA mode 1 and below are supported F 0 1 = Multiword DMA mode 0 is supported 15F 64 Reserved 8 0003h F 7-0 Advanced PIO modes supported 0078h F Minimum Multiword DMA transfer cycle time per word 66 0078h F Manufacturer’s recommended Multiword DMA transfer cycle time 67 0078h F Minimum PIO transfer cycle time without flow control 68 0078h F Minimum PIO transfer cycle time with IORDY flow control 69-79 0000h F Reserved (for future command overlap and queuing) ia l 65 81 0021h 14 Reserved for ATA/ATAPI-14 F 13 Reserved for ATA/ATAPI-13 F 12 Reserved for ATA/ATAPI-12 F 11 Reserved for ATA/ATAPI-11 F 10 Reserved for ATA/ATAPI-10 F 9 Reserved for ATA/ATAPI-9 F 8 Reserved for ATA/ATAPI-8 F 7 1 = supports ATA/ATAPI-7 F 6 1 = supports ATA/ATAPI-6 F 5 1 = supports ATA/ATAPI-5 F 4 1 = supports ATA/ATAPI-4 F 3 Obsolete X 2 Obsolete X 1 Obsolete F 0 Reserved F or ig ht c F em 01FEh 15 Reserved M 80 F on fid en t Major version number 0000h or FFFFh = device does not report version Minor version number Command set supported. 82 0068h X 15 Obsolete F 14 1 = NOP command supported F 13 1 = READ BUFFER command supported F 12 1 = WRITE BUFFER command supported X 11 Obsolete F 10 1 = Host Protected Area feature set supported Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 19 of 27 STM-25 Word Value F/V Description F 9 1 = DEVICE RESET command supported F 8 1 = SERVICE interrupt supported F 7 1 = release interrupt supported F 6 1 = look-ahead supported F 5 1 = write cache supported F 4 Shall be cleared to zero to indicate that the PACKET Command feature set is not supported. 3 1 = mandatory Power Management feature set supported F 2 1 = Removable Media feature set supported F 1 0 = Security Mode feature set unsupported F 0 1 = S.M.A.R.T. feature set supported F 15 Shall be cleared to zero F 14 Shall be set to one F 13- Reserved ia 1 = SET MAX security extension supported F 7 Reserved F 6 1 = SET FEATURES subcommand required to spinup after power-up F 5 1 = Power-Up In Standby feature set supported F 4 1 = Removable Media Status Notification feature set supported F 3 1 = Advanced Power Management feature set supported F 2 1 = CFA feature set supported F 1 1 = READ/WRITE DMA QUEUED supported F 0 1 = DOWNLOAD MICROCODE command supported or ig 8 em 5000h F M 83 ht c 9 on fid en t Command sets supported. l F Command set/feature supported extension. 84 F 15 Shall be cleared to zero F 14 4000h Shall be set to one 13F Reserved 2 F 1 1 = S.M.A.R.T. self-test supported F 0 1 = S.M.A.R.T. error logging supported Command set/feature enabled. 85 0008h X 15 Obsolete F 14 1 = NOP command enabled Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 20 of 27 STM-25 Word Value F/V Description F 13 1 = READ BUFFER command enabled F 12 1 = WRITE BUFFER command enabled X 11 Obsolete V 10 1 = Host Protected Area feature set enabled F 9 1 = DEVICE RESET command enabled V 8 1 = SERVICE interrupt enabled V 7 1 = release interrupt enabled V 6 1 = look-ahead enabled V 5 1 = write cache enabled F 4 Shall be cleared to zero to indicate that the PACKET Command feature set is 3 1 = Power Management feature set enabled F 2 1 = Removable Media feature set enabled V 1 1 = Security Mode feature set enabled V 0 1 = S.M.A.R.T. feature set enabled Command set/feature enabled. 15Reserved ht c F 9 8 1 = SET MAX security extension enabled by SET MAX SET PASSWORD F 7 See Address Offset Reserved Area Boot, INCITS TR27:2001 F 6 1 = SET FEATURES subcommand required to spin-up after power-up V 5 1 = Power-Up In Standby feature set enabled V 4 1 = Removable Media Status Notification feature set enabled V 3-1 1 = Advanced Power Management feature set enabled F 0 ig F em or 5000h M 86 on fid en t F ia l not supported. 1 = DOWNLOAD MICROCODE command supported Command set/feature default. 87 F 15 Shall be cleared to zero F 14 Shall be set to one F 13- Reserved 4000h 2 F 1 1 = S.M.A.R.T. self-test supported F 0 1 = S.M.A.R.T. error logging supported 15- Reserved 88 13 203Fh V 12 1 = Ultra DMA mode 4 is selected Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 21 of 27 STM-25 Word Value F/V Description 0 = Ultra DMA mode 4 is not selected 1 = Ultra DMA mode 3 is selected V 11 0 = Ultra DMA mode 3 is not selected 1 = Ultra DMA mode 2 is selected V 10 0 = Ultra DMA mode 2 is not selected 1 = Ultra DMA mode 1 is selected V 9 0 = Ultra DMA mode 1 is not selected 1 = Ultra DMA mode 0 is selected V 8 F 4 1 = Ultra DMA mode 4 and below are supported F 3 1 = Ultra DMA mode 3 and below are supported F 2 1 = Ultra DMA mode 2 and below are supported F 1 1 = Ultra DMA mode 1 and below are supported F 0 1 = Ultra DMA mode 0 is supported ia 7-5 Reserved on fid en t F l 0 = Ultra DMA mode 0 is not selected 0000h F Time required for security erase unit completion 90 0000h F Time required for Enhanced security erase completion 91 0000h V Current advanced power management value 92 0000h V Master Password Revision Code 93 0000h X Hardware reset result 94-126 0000h V Reserved or ig ht c 89 15F Reserved M 2 127 em Removable Media Status Notification feature set support 00 = Removable Media Status Notification feature set not supported 0000h 01 = Removable Media Status Notification feature supported F 1-0 10 = Reserved 11 = Reserved Security status 15F Reserved 9 V 128 8 Security level 0 = High, 1 = Maximum 0001h F 7-6 Reserved F 5 1 = Enhanced security erase supported V 4 1 = Security count expired V 3 1 = Security frozen Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 22 of 27 STM-25 Word Value F/V Description V 2 1 = Security locked V 1 1 = Security enabled F 0 0 = Security unsupported 129-159 0000h X Vendor specific 160-254 0000h X Reserved Integrity word 255 15- Checksum 0000h X 8 ia l 7-0 Signature IDLE (E3h) This command causes the device to set BSY, enter the Idle mode, clear BSY and generate an interrupt. If sector count is non-zero, the automatic power down mode is enabled. If the sector count iszero, the automatic power mode is disabled. • IDLE IMMEDIATE (E1h) This command causes the device to set BSY, enter the Idle(Read) mode, clear BSY and generate an interrupt. • INITIALIZE DEVICE PARAMETERS (91h) This command enables the host to set the number of sectors per track and the number of tracks per heads. • READ DMA (C8h) Read data from sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value. A sector count of zero requests 256 sectors. • READ MULTIPLE (C4h) This command performs similarly to the Read Sectors command. Interrupts are not generated on each sector, but on the transfer of a block which contains the number of sectors defined by a Set Multiple command. • READ SECTOR(S) (20h/21h) This command reads 1 to 256 sectors as specified in the Sector Count register from sectors which is set by Sector number register. A sector count of the requests 256 sectors. The transfer beings specified in the Sector Number register. M em or ig ht c on fid en t • Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 23 of 27 STM-25 READ VERIFY SECTOR(S) (40h/41h) This command verifies one or more sectors on the drive by transferring data from the flash media to the data buffer in the drive and verifying that the ECC is correct. This command is identical to the Read Sectors command, except that DRQ is never set and no data is transferred to the host. • RECALIBRATE (10h) The current drive performs no processing if it receives this command. It is supported for backward compatibility with previous devices. • SEEK (7xh) This command is effectively a NOP command to the device although it does perform a range check. • SET FEATURES (EFh) This command set parameter to Features register and set drive’s operation. For transfer mode, on fid en t ia l • Table 12 Featured register and valid operating mode ht c parameter is set to Sector Count register. This command is used by the host to establish or select certain features. Function 02h Enable write cache 03h Set transfer mode based on value in Sector Count register. 55h Disable read look-ahead feature 82h Disable write cache AAh Enable read look-ahead feature M em or ig Value • SET MULTIPLE MODE (C6h) This command enables the device to perform READ MULTIPLE and WRITE MULTIPLE operations and establishes the block count for these commands. • SLEEP (E6h) This command causes the device to set BSY, enter the Sleep mode, clear BSY and generate an interrupt. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 24 of 27 STM-25 S.M.A.R.T. Function Set (B0h) Performs different processing required for predicting device failures, according to the subcommand specified in the Features register. If the Features register contains an unsupported value, the Aborted Command error is returned. If the S.M.A.R.T. function is disabled, any subcommand other than S.M.A.R.T. ENABLE OPERATIONS results in the Aborted Command error. • STANDBY (E2h) This command causes the device to set BSY, enter the Sleep mode (which corresponds to the ATA“Standby” Mode), clear BSY and return the interrupt immediately. • STANDBY IMMEDIATE (E0h) This command causes the drive to set BSY, enter the Sleep mode (which corresponds to the ATA “Standby” Mode), clear BSY and return the interrupt immediately. • WRITE DMA (CAh) Write data to sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value. • WRITE MULTIPLE (C5h) This command is similar to the Write Sectors command. Interrupts are not presented on each sector, but on the transfer of a block which contains the number of sectors defined by Set Multiple command. • WRITE SECTOR(S) (30h/31h) Write data to a specified number of sectors (1 to 256, as specified with the Sector Count register) from the specified address. Specify “00h” to write 256 sectors. M em or ig ht c on fid en t ia l • Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 25 of 27 STM-25 10. Memoright SSD Marking Information ht c ig or M em 10.1.1 Label Content  Memoright Logo  CE Logo  FCC Logo  WEEE Logo  RoHS (pb-free) Logo  Warranty Warning  BSMI Logo on fid en t ia l 10.1Top View Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 26 of 27 STM-25 11. Contact Information Memoright Worldwide Headquarters General Support +886-2-2218-3789 Xindian Dist., New Taipei Fax +886-2-2218-5155 City 231, Taiwan E-mail [email protected] on fid en t ia l 9F, 535, Zhongzheng Rd, ht c DISCLAIMER OF LIABILITY Memoright Corp. reserves the right to make changes to specifications and product descriptions such as but not limited ig to numbers, parameters and other technical information contained herein without notice. Please contact Memoright or Corp. to obtain the latest specifications. Memoright Corp. grants no warranty with respect to this datasheet, explicit or implied, and is not liable for direct or indirect damages. Some states do not grant the exclusion of incidental damages em and as such this statement may not be valid in such states. The provisions of the datasheet do not convey to the others M purchaser of the device any license under any patent right or other intellectual property right of Memoright Corp. or COPYRIGHT NOTICE Copyright © 2012 by Memoright Corp. All rights reserved. Information contained in this document, including but not limited to any instructions, descriptions and product specifications, is considered proprietary and confidential to Memoright Corp. and shall not be modified, used, copied, reproduced or disclosed in whole or in part, in any form or by any means, electronic or mechanical, for any purpose, without the written consent of Memoright Corp. Memoright Corp. 9F,535, Zhong Zheng Rd, Xin Dian Dist., New Taipei City, Taiwan Memoright reserves the right to change products or specifications without notice. Revision: 1.0 Page 27 of 27