Transcript
1.25Gbps 20km LC BIDI SFP Transceiver Rev. A1, Apr.11 2015
SGE20-D4C-35/53 Features ◆ Up to 1.25Gbps Data rate ◆ 1550nm DFB Laser and PIN photo detector for SGE20-D4C-53 ◆ 1310nm FP Laser and PIN photo detector for SGE20-D4C-35 ◆ Simplex LC receptacle optical interface compliant ◆ Single +3.3V power supply ◆ Hot-pluggable ◆ AC coupling of LVPECL signals ◆ International Class1 laser safety certified ◆ Operating temperature range: Commercial:0℃~+70℃ ◆ RoHS Compliant ◆ DDMI function available with internally calibrated mode
Application ◆ Gigabit Ethernet ◆ Gigabit Fiber Channel ◆ Switch to switch interface ◆ Switched backplane applications
Standard ◆ Compliant with SFP MSA (INF-8074i) ◆ Compliant with SFF-8472 ◆ Compatible with IEEE802.3ah 2004
www.mnc-tek.com
Page 1 of 11
东莞铭普光磁股份有限公司 Dongguan Mentech Optical & Magnetic Co., Ltd.
1.25Gbps 20km LC BIDI SFP Transceiver Rev. A1, Apr.11 2015
Specification: Absolute Maximum Ratings Parameter
Symbol
Min
Max
Unit
Storage temperature
TS
-40
85
℃
Power Supply Voltage
Vcc
-0.5
+4
V
Relative Humidity
RH
5
95
%
Recommended Operating Conditions Parameter Operating Case Temperature(Industry) Power Supply Voltage
Symbol
Min
Tc
-40
Vcc
3.135
Supply Current
Icc
Typical
3.3
Data Rate
Max
Unit
85
℃
3.465
V
300
mA
1.25
Fiber Length 9/125μm core SMF
Gbps -
km
Max
Unit
Notes
400
2400
mV
600
1200
mV
Voh
2
Vcc
V
LVTTL
Vol
0
0.8
V
LVTTL
Voh
2
Vcc
V
LVTTL
Vol
0
0.8
V
LVTTL
Voh
2
Vcc
V
LVTTL
Vol
0
0.8
V
LVTTL
Max
Unit
Notes
-3
dBm
-
20
Electrical Characteristics Parameter Transmitter differential input voltage Receiver differential output Voltage Transmit Fault (TX_Fault) Loss of Signal (LOS) TX Disable
Symbol
Min
Typical
Optical transmitter Characteristics Parameter
Symbol
Min
Launched Power (avg.)
Pout
-8
Operating Wavelength Range
λc
www.mnc-tek.com
Typical
1270
1310
1355
1500
1550
1580
SGE20-D4C-35 nm SGE20-D4C-53 Page 2 of 11
东莞铭普光磁股份有限公司 Dongguan Mentech Optical & Magnetic Co., Ltd.
1.25Gbps 20km LC BIDI SFP Transceiver Rev. A1, Apr.11 2015 Spectral Width
FP
4
∆λ
nm
DFB
1 Side Mode Suppression Ratio
SMSR
30
dB
DFB
Extinction Ratio
ER
9
dB
2
Relative Intensity Noise
RIN
-120
Return Loss Tolerance
12
dB/Hz dB
Total Jitter
Tj
0.284
UI
2
Optical Rise/Fall Time
Tris/Tfall
260
Ps
3
Transmitter and Dispersion Penalty
TDP
1
dB
Optical Tx Output disable
Pdis
-45
dBm
Output Eye Diagram
Complies with IEEE802.3z eye masks when filtered Optical receiver Characteristics
Parameter
Symbol
Receiver Sensitivity
S
Wavelength Range
λc
Min
Typical
LOS
Unit
Notes
-23
dBm
4
1500
1580
1270
1355
Receiver Reflectance Optical Power Input Overload
Max
-12 Pin-max
Optical Dessert
Pd
Optical Assert
Pa
LOS hysteresis
0.5 -24 -35 0.5
5
nm
SGE20-D4C-35 SGE20-D4C-53
dB dBm
4
dBm
4
dB
5
Note1. The supply current is SFP module’s working current. Note2: For the measurements, the device was driven with 1.25Gbps data pattern with 2 7-1 PRBS payload Note3. Optical transition time is the time interval required for the rising or falling edge of an optical pulse to transition between the 20% and 80% amplitudes relative to the logical 1 and 0 levels Note4. Measured with a PRBS 2 7-1 test pattern, @1.25Gbps, EX=10dB, BER<10 -12 Note5. The LOS Hysteresis to minimize ―chatter‖ on the output line. In principle, Hysteresis alone does not guarantee chatter-free operation
Digital Diagnostic Monitoring Information Parameter
Accuracy
Calibration
Note
Temperature
±3°C
internal
-5~75
Voltage
±3%
internal
Vcc=3.3V±5%
Bias Current
±10%
internal
Specified by normal value
TX Power
±2dB
internal
-9~-3dBm
RX Power
±3dB
internal
-24~0dBm
www.mnc-tek.com
Page 3 of 11
东莞铭普光磁股份有限公司 Dongguan Mentech Optical & Magnetic Co., Ltd.
1.25Gbps 20km LC BIDI SFP Transceiver Rev. A1, Apr.11 2015
Pin Description
As Viewed Through Top of Board
Pin 1
Name VeeT
Function/Description Transmitter Ground
Engage-ment 1
order
2 3
TX Fault TX Disable
Transmitter Fault Indication Transmitter Disable-Module disables on high or open
3 3
1 2
4
MOD-DEF2
Module Definition 2-Two wire serial ID interface
3
3
5 6
MOD-DEF1 MOD-DEF0
Module Definition 1-Two wire serial ID interface Module Definition 0-Two wire serial ID interface
3 3
3 3
7 8
Rate Select LOS
Not Connected Loss of Signal
3 3
4
9
VeeR
Receiver Ground
1
10
VeeR
Receiver Ground
1
11
VeeR
Receiver Ground
1
12
RD-
Inverse Received Data out
3
5
13
RD+
Received Data out
3
5
14
VeeR
Receiver Ground
1
15
VccR
Receiver Power —— +3.3V±5%
2
6
16
VccT
Transmitter Power —— +3.3 V±5%
2
6
17
VeeT
Transmitter Ground
1
www.mnc-tek.com
Page 4 of 11
东莞铭普光磁股份有限公司 Dongguan Mentech Optical & Magnetic Co., Ltd.
1.25Gbps 20km LC BIDI SFP Transceiver Rev. A1, Apr.11 2015 18
TD+
Transmitter Data In
3
7
19
TD-
Inverse Transmitter Data In
3
7
20
VeeT
Transmitter Ground
1
Note1. TX Fault is open collector/drain output which should be pulled up externally with a 4.7K – 10KΩ resistor on the host board to supply 1000V for SFI
(ESD) to the Electrical Pins
Method 3015.7
Electrostatic Discharge (ESD) Immunity
IEC61000-4-2
Electromagnetic
CISPR22 ITE Class B FCC Class B
Interference (EMI)
CENELEC EN55022 VCCI Class 1
Immunity
IEC61000-4-3 FDA 21CFR 1040.10 and
Eye Safety
www.mnc-tek.com
1040.11 EN (IEC) 60825-1,2
pins, >2000V
for other pins.)
Class 2(>4.0kV)
Comply with standard
Comply with standard Compatible with Class I laser Product
Page 10 of 11
东莞铭普光磁股份有限公司 Dongguan Mentech Optical & Magnetic Co., Ltd.
1.25Gbps 20km LC BIDI SFP Transceiver Rev. A1, Apr.11 2015
Ordering information Specifications Part. No
Pack
Rate (Gbps)
SGE20-D4C-35
SFP
1.25
SGE20-D4C-53
SFP
1.25
www.mnc-tek.com
Tx Po (nm) (dbm) 1310 FP 1550 DFB
RX
Sen (dbm)
Temp (℃)
Reach (KM)
DDM
-8~-3
PIN
<-23
0~+70
20
Y
-8~-3
PIN
<-23
0~+70
20
Y
Page 11 of 11