Preview only show first 10 pages with watermark. For full document please download

Menu Map Sheet 

   EMBED


Share

Transcript

321-56867-21A Sep. 2009 Menu Map Sheet Press or menu option. For details on the organization of the menu settings and the method of operation of the menu, see "3. MENU SETTINGS" (^ page 40). STAND POURING Press [MENU/ENTER]. P.77 General weighing mode Refers to a page in the instruction manual. Press The default settings (settings when the menu is reset) to confirm. WIN|.U WIN- WIN-.U WindowsDirect communication function APL.FUNC PCS SAMPLE Item number ~ PERCENT SAMPLE 100% reference Piece counting Percentage weighing OPTION FORMULA TOOLS Other functions WIN| WIN|.U WIN- WIN-.U P.111 WindowsDirect communication function APL.PRN P.111 Press [PRINT] for 3 sec. Application output AUTO.PRN LD. . LD.UL. LD. .Z LD.UL.Z LD.OK. Auto print function P.71 Zero tracking function Application function mode Weight display P.77 Pouring mode WIN| Z.TRC Press to proceed to the next menu option. Data Output Menu Main Menu Weight display Press to return to the previous menu option. (Pressing for around 3 seconds during menu operation returns you to the weighing mode.) to search for the TARGT TG.VAL CHECK.W OVR.RNG HI.LIM LO.LIM UND.RNG Checkweighing mode PARAM.W SEQ.PRN Continuous output function P.96 Output timing change function PRINT.F COMM.SET Target value Communication settings Permissible range Checkweighing range upper limit Pass range upper limit Pass range lower limit FAST BAND System POINT Decimal point indication Zero or negative value MODE.1 MODE.2 MODE.3 MODE.4 MODE.5 Key operation 0.5D 1D 10D 50D 100D 1000D P.129 P.126 Standard settings (MODE1 - MODE5) MODE.U BPS Baud rate P.80 P.79 PARITY Parity B. 300 B. 600 B.1200 B.2400 B.4800 B.9600 B. 19.2K B. 38.4K [300] P.NONE P.ODD P.EVEN None S. 1 S. 2 1 bit HS.OFF HS.HW HS.SW H.S.TIM None [600] [1200] [2400] P.127 [4800] [9600] [19.2 K] [38.4 K] P.127 Odd Even PERIOD Period STOP P.42 AUTO.OFF Auto power-off BC.LIT Backlight (TXB series only) Stop bit HAND.SHK Handshake P.138 P.140 AUTO SEM.AUTO DF. DF. DF. DF. D.FORM Weighing mode OFF display Data format P.139 MANU 1 2 3 4 P.127 2 bits Hardware Software P.127 Timer Data format 1 Data format 2 Data format 3 Data format 4 P.128 DF.FRE All segments lit D. HEAD Head byte D. LEN Data length Free format BAL.ID Balance ID P.69 PASS.WRD Password P.141 COND.OUT Menu settings output P.53 Menu reset P.51 RESET P.108 No filter COMMA START 50% SOON User-specified settings Comma Start display RET.50 On OK Fast Stability detection range SYSTEM P.104 Checkweighing range lower limit Stability mark RET. 0 Zero return judgment On -0Ld MANU NO.FIL P.92 Specific percentage reference STB.MK Weighing parameters Z.RET On 0Ld P.106 P.102 LM.VAL On -Ld P.87 Formulation Target mode On Ld DELIM CR LF CR+LF COMMA Delimiter CR LF CR+LF Comma WIN| P.128 WIN|.U WindowsDirect communication function WIN- Unit setting menu Weight display Press [UNIT] for 3 sec. UNIT- g g UNIT- mg #1 UNIT- kg #2 UNIT- ct Calibration menu P.83 Other units cannot be selected in some countries due to legal restrictions. #1: mg cannot be selected on models whose minimum indication is 10 mg or greater. #2: kg cannot be selected on the TWC***L and TXC***L. UNIT-U CONV.K User-specified units Minimum indication MIN.D Conversion factors P.84 P.85 CAL.EXE Weight display Calibration E.CAL E.TEST I.CAL I.TEST Press [CAL] for 3 sec. GLP.OUT P.CAL WIN-.U Zero / tare menu Span calibration using an external weight Calibration check using an external weight Span calibration using the internal weight (TW series only) Calibration check using the internal weight (TW series only) P.57 P.62 Weight display P.56 P.60 GLP output function P.142 Calibration of the internal weight (TW series only) P.64 Press [O/T] for 3 sec. Z.TRC Zero tracking function P.71 A.TARE Auto tare function P.74 A.ZERO Auto zero function P.72 TARE.F SOON Zero / tare timing change function P.75 Operation Control Panel Operation keys Display panel Key No. 5 [MENU/ENTER] 6㨇UNIT㨉 6 [UNIT] Press Once and Release Press and Hold for About 3 Seconds 1 [BREAK] Switches between the operation and standby modes 2 [CAL] Performs calibration Enters the calibration menu 3 [O/T] Tares the balance (setting it to zero) Opens the zero / tare menu [PRINT] Outputs the weight reading to a peripheral device (printer or PC) Opens the data output menu 4 - Menu operation keys 7 7㨇FUNC㨉 [FUNC] 2 㨇CAL㨉 1 㨇BREAK㨉 3 㨇O/T㨉 4 㨇PRINT㨉 Operation keys With the TXB series, Menu operation keys is provided. Display panel 1 b No. 1 Display c 3 d e 4 f 5 g 6 h i 7 j Name Battery symbol 8 9 k 0 l m a n Description See: Lit when the weight reading is stable. Also lit when the option currently set in menu setting is displayed. ^ P.33 Press and Hold for About 3 Seconds Displays the main menu Shows the menu displayed last 6 [UNIT] • In the weighing mode: Used to select the unit • When piece counting: Displays the unit weight • When performing percentage weighing: Displays the reference weight • In the weighing mode: Opens the unit setting menu • When piece counting: Used to select the item number • When performing percentage weighing: Used to select the percentage reference 7 [FUNC] Switches between the weighing mode and the application function mode Selects the minimum number of displayed digits 8 [Res] The response of the display is increased. - 9 [Stb] The stability of the display is increased. - No. 2 Press Once and Release [MENU/ENTER] 5 9㨇Stb㨉 9 [Stb] 8㨇Res㨉 8 [Res] ∗1 Key No. ∗1 Display Name Description See: 9 Auto print symbol Lit when the Auto Print function is set. ^ P.108 0 Win symbol Lit when the WindowsDirect communication function has been set. ^ P.112 a Communication symbol Indicates that data is being exchanged with an external device. b Comparator symbol When the comparator function (Checkweighing) has been set, indicates the comparison judgment. ^ P.102 c Stability mark Lit when the weight reading is stable. Lit when the option currently set in menu setting is displayed. ^ P.48 ^ P.79 d Minus symbol Lit when the weight reading is negative. e Ready symbol Lit during the standby mode (TX series only). Also, during weighing, lit to indicate the ready to weigh status, for example when using the formulation function. ^ P.43 ^ P.96 f Number symbol Lit when it is possible to enter numerical values. ^ P.49 g Hold symbol Lit when a value that is not the real-time weight reading (for example the indication of the unit weight in piece counting) is displayed. ^ P.90 ^ P.95 h Net weight symbol Indicates that the weight reading displayed in mixing measurement (formulation) is the net weight of the current component with the weight of the container and prior components. Also indicates that a measuring operation is in progress. ^ P.97 i Gross weight symbol Indicates that the weight reading displayed in mixing measurement (formulation) is the total weight of all of the components of the mixture with the weight of the container subtracted. ^ P.97 - - 2 Zero tracking symbol Lit when the zero tracking function is set ON. ^ P.71 3 Weight symbol This symbol is lit during calibration. ^ P.57 ^ P.62 j Item number indication Shows the item number in the piece counting mode. ^ P.90 4 Easy setting indicator Indicates what level the response and stability are currently set to. ^ P.78 k Inverse triangle symbol ^ P.50 5 Pouring symbol Lit when the pouring mode is set. ^ P.77 When this symbol is lit when changing the position of the decimal point in the conversion factor with the user-specified units, numerical values can be entered without a decimal point. Formulation symbol Lit during mixing measurement (formulation) operations. ^ P.96 l Piece counting symbol Lit while the piece counting mode is in effect. 6 ^ P.90 7 Menu lock symbol Lit while the menu is locked. ^ P.52 m Specific percentage weighing symbol Lit when the specific percentage reference has been set for percentage weighing. ^ P.94 8 Menu operation key symbol During menu operation, indicates which of the menu operation keys can be used. ^ P.47 n Percentage weighing symbol Lit during percentage weighing. ^ P.95