Preview only show first 10 pages with watermark. For full document please download

Menuselect Control Service Guide

   EMBED


Share

Transcript

Menuselect BC20 Control Service Guide To Access the following menus, press the MAINT button Use the rotation of the knob to select Menu Items and press the knob in to select an item. Also use the knob rotation or the number keys as needed to modify values and press the knob to enter the new values. 1|Page Manager Programming: Code = 6647 If needed Item Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Description Copy RCP (Recipes) From USB Copy RCP (Recipes) To USB Copy HACCP to USB Date (mm/dd/yyyy) Time (24Hr) Auto Start Manager Passcode Recipe Passcode Temperature Unit Cool Down Temp Temp Display Rate (mm:ss) Input Response Time (mm:ss) Setback Time (hh:mm) Ready Beep Cook Done Beeper Pause (3x only if enabled) Cook Cool Fan enable Restore Manual Remote Beeper RCP Cook Mode SW Boiler Set Temp Preheat Boiler Set Temp Cook Delime Fill Time (mm:ss) Delime Interval (30,60 or 90 Hrs) Flush Interval (hours) Prime Delime Pump Exit Default Setting BC20G Off No No F 100F 00:00 00:10 00:00 On No Yes No Yes Yes 185F 212F 01:00 30Hr 24Hr Factory Programming: Code = 3228 If needed Item Number 1 2 3 4 5 6 7 8 Description Copy FCT From USB Copy FCT To USB Appliance Type Boiler Enable Temperature Unit Min Hot Air Temp Max Hot Air Temp Min Steam Temp Default Setting BC20G Gas Yes F 140F 500F 85F 2|Page 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Max Steam Temp Max Core Probe Temp Upper Hot Air Hys Lower Hot Air Hys Upper Steam Hys Lower Steam Hys Upper Ready Band Lower Ready Band Cavity Probe Offset Core Probe Offset Setback Temp Combi Setback Temp Steam Max Steam Demand Time SCK Address Factory Passcode ? Service Passcode ? Exit 225F 350F 2F 2F 2F 2F 25F 10F 0F -2F 300F 180F 20:00 30 Yes Yes Service: Code = 7378 if Needed 1. Counters Item Number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 Count Description Heat Fan Speed Low Fan Speed High Steam Valve Cook Done Cooling Fan Hot Air Hot Air Enable Door Core Probe Delime Valve Boiler Heat Fill Valve Drain Valve Delime Total Delime Delay Delime Cancel Flush Total Flush Delay 3|Page 20 21 22 23 24 2. Clear Counters (No/Yes) 3. Error Log Item Number 1 2 3 4 5 6 4. Clear Error Log (No/Yes) 5. Diagnostic Output Diagnostic Key (momentary) TEMP COMBI RETHERM PROG ESC TIME HOT AIR PROBE MAINT 5 8 6. Diagnostic Input Diagnostic Key TEMP COMBI RETHERM PROG STEAM STEAM ON DEMAND 4 7 7. Exit Delime 1 Flush Cancel HACCP to USB RCP From USB RCT to USB Exit Error Log Cavity Probe Error Cavity High Temp Error Cooling Fan Probe Error Fan Error Boiler Probe Error Exit Diagnostic Output Heat Fan Speed High Fan Speed Low Fill Cooling Fan Cook Done Delime Boiler Heat Drain Hot Air Hot Air Enable Diagnostic Input Fan Error Door Cavity Probe Temp Cool Fan Probe Temp Water Hi Level Switch Water Lo Level Switch Core Probe Temp Boiler Probe Temp Start Delime (Yes/No) 4|Page 2 3 4 Delime Interval (hours) Next Delime (hh:mm) Exit 1 2 3 4 Start Flush (Yes/No) Flush Interval (hours) Next Flush (hh:mm) Exit Flush Exit Below are the Error Codes the control can display and their meaning: Code Meaning Delime Error Water Level Switch Delime Error Boiler Temp Flush Error Water Level Switch Cooling Fan Probe Error Fan Error Com Error Cavity Probe Error Cavity High Temp Error The water level switches did not change in 15 minutes during a Delime sequence while draining or filling. The Boiler probe did not reach 185F within 15 minutes during a Delime sequence. The water level switches did not change in 15 minutes during a Flush sequence while draining or filling. The cooling fan probe reads less than 32F or greater than 575F. The Drive At Speed signal is missing for 15 Seconds. The control lost signals from the relay board for 3 seconds. The cavity probe reads less than 32F or greater than 575F. The cavity probe reads greater than 565F for Gas or 650F for electric OR reads 150F above the cavity set temperature. The cavity probe temperature does not raise 1F in 5 minutes during a call for cavity heat. The boiler probe reads greater than 250F. No Heat Error Boiler High Temp Error Boiler Hi Limit Switch Boiler Probe Error Water Level Error The boiler manual reset high limit tripped and is sending a signal to the relay board. It trips at 248F. The boiler probe reads less than 32F or greater than 575F. The water high level switch does not open after 15 minutes of filling during any time that is not delime or flushing. 5|Page