Preview only show first 10 pages with watermark. For full document please download

Merit Series Cr-3835r/l Appliance Specifications ™

   EMBED


Share

Transcript

MERIT™ SERIES CR-3835R/L Appliance Specifications 17 1/2" (445mm) 17 1/2" (445mm) 40 1/2" (1029mm) 40 1/2" (1029mm) 32 7/8" 21" (835mm) (533m) 37 3/8" (949mm) 38 5/8" (981mm) 42 3/4" (1086mm) 6" (152mm) 32 7/8" (835mm) Left Corner Opening 10" (254mm) 35" (889mm) 10" (254mm) 10" (254mm) 15" (381mm) 40 1/4" (1022mm) 24" (610mm) 19 7/8" (505mm) 10 1/2" (267mm) Top View Part Number P/N 015014 P/N 015013 40 1/4" (1022mm) 7 1/2 (191mm) 42 3/4" (1086mm) Model CR-3835R CR-3835L 38 5/8" (981mm) 42 3/4" (1086mm) 6" (152mm) Right Corner Opening 10" (254mm) 37 3/8" (949mm) 21" (533m) Weight 210 lbs. 210 lbs. Open End Closed End Note: All specifications, ratings and dimensions are subject to change without notice. Fireplace Finishes Mantels And Trim Hearth Extensions & Wall Shields Combustible mantels and trim may be installed 12" (305 mm) above the fireplace opening as per NFPA 211; Section 7-2.3.3. and the Mantel limitation diagram. If a mantel is of a noncombustible material, it is exempt from these requirements as long as it does not interfere with the installation or operation of glass doors. A hearth extension must be installed with all fireplaces. It is to protect the floor in front of the fireplace from both radiant heat and sparks. When installed in an outside corner, the hearth extension must extend 12” beyond the front extension opening and 8” beyond the side opening. When installed in an inside corner, the hearth extension must extend to the wall. In all cases, the heath extension must extend 20” beyond the black metal fireplace facing into the room. Header 12" Max. 1 1/2" If Less Than 12" (305mm) Wall Shield Required 40" (1016mm) Combustible Mantel and Trim 12"* Min. Spacer 8 3/8"* Finished Wall Fireplace Opening Typical Installation *Both Of These Dimensions Must Be At Least 18” When An Unvented Gas Log Set Rated At 26,000 BTU Or Higher Is Used. (Maximum 40,000 BTU) 40" (1016mm) Wall Shield Not Required On This Wall Wall Shield Metal Safety Strip 20" (508mm) 20" (508mm) Inside Corner NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 775,621M Rev. A 04/07 MERIT™ SERIES CR-3835R/L Framing Specifications Note: All framing dimensions calculated for ¹⁄₂" dry wall at the appliance face. If sheathing the chase or finishing with other thickness materials, calculations will need to be made. Typical Installation Chimney And Termination Back Wall of Chase/Encloslure Including Finishing Materials if any Note: No Wall Shield Required On This Wall D Rough Framing Face (Unfinished Shown) C 8" Max. (203mm) 11 ⁷⁄₈" (302mm) 45° 8" (203mm) Min. To Protected Side Wall CCEK W.H.I. Approved (Required In Canada) Note: Combustible Materials May Be Placed In Shaded Area. Inside Corner Using Outside Air Framing Dimensions Back Wall of Chase/Encloslure Including Finishing Materials if any A 42 5/8" (1082 mm) B 40 5/8" (1032 mm) C 24" (610 mm) D 34 7/8" (866 mm) C A Rough Framing Face (Unfinished Shown) Outside Combustion Air Kit (Optional) Outside Corner B B A Header Ceiling Framing A D C C Framing Dimensions for Ceiling Framing Without False Header Roof Framing Flue Type A B FTF8 Vertical at 2" 16 1/2" 16 1/2" FTF10 Vertical at 1" 17" 17" FTF10 Vertical at 2" 19" 19" FTF8 Offset 30° at 2" 16 1/2" 27" FTF10 Offset 30° at 1" 17" 26" FTF10 Offset 30° At 2" 19" 28" Framing Dimensions for Roof Pitch FTF8 at 2" FTF10 at 1" FTF10 at 2" C D* C D* C D* 0/12 16 1/2" 16 1/2" 17" 17" 19" 19" 6/12 16 1/2" 19" 17" 19" 19" 21" 12 /12 16 1/2" 23 1/2" 17" 24" 19" 26" *Perpendicular to roof ridge Note: For millimeters multiply by 25.4. NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE. 775,621M Rev. A 04/07