Transcript
TURNING AIR INTO SOLUTIONS.
MIXED FLOW FANS MODEL QSL (Standard) | QSLR (Restaurant) | QSLSH (Smoke and Heat)
CATALOGUE M1060 April 2015
MIXED FLOW FANS
Models
QSL | QSLR | QSLSH Benefits of Mixed Flow Fans
Twin City Fan Model QSL Mixed Flow Fan combines the benefits of axial flow and centrifugal flow fans. The QSL has the advantage of the compact design and straight-through airflow as well as the preferred acoustic characteristics and high pressure capability. QSL fans offer superior air and sound performance and the AMCA certified rating seal for air and sound.
Energy Savings
Mixed flow fans offer the economy of operation with a higher and broader efficiency range. The lower operating speed for a given performance provides longer and more reliable operation.
Ultra Quiet
The AMCA Certified Ratings for Air and Sound applies to both inlet and outlet sound power levels. The table below displays sound and static efficiency differences between performance points for a comparable tubular centrifugal fan and a vane axial fan.
QSL Mixed Flow Fan, Outlet View
Static Efficiency (%)
Sound LwA (dB)
Performance
Size
QSL
TSL
TCVA
QSL
TSL
TCVA
2.35 m3/sec @ 250 Pa
QSL 245
70
55
61
72
77
79 82
4.72 m /sec @ 250 Pa
QSL 330
70
63
63
72
81
11.80 m3/sec @ 750 Pa
QSL 402
72
68
65
86
92
98
23.60 m3/sec @ 1500 Pa
QSL 490
71
69
64
95
102
112
3
Mixed Flow Models QSL – Available in both direct drive and belt driven.
The QSL mounts both vertically and horizontally, allowing for numerous applications with multiple mounting arrangements. Sizes range from 150 - 730 and performance ranges from 0.6 to 75 m3/sec. Model QSL is UL/CUL 705 listed.
QSLR – Model QSLR is similar to the QSL but is specifically designed for exhausting grease-laden air from kitchens, restaurants and cooking and dishwasher hoods. Model QSLR is UL/CUL 762 listed for the exhaust of grease-laden air. QSLSH – Model QSLSH is specifically designed for
Application
Mixed flow fans are becoming a popular choice on many air supply, return, general and grease-laden exhaust and laboratory exhaust applications in the HVAC industry for both constant or variable air volume systems. The efficiency and sound characteristics of the mixed flow fans are often desired in buildings such as hospitals, libraries, theaters, and general offices. The Twin City Fan heavy-duty construction of QSL fans also make them suitable for many industrial applications handling ambient air. Applications involving fumes, spray booth exhaust, particulate, heavy moisture content, or high temperature should be discussed with the factory for possible product modifications.
smoke control applications. UL/CUL listed for smoke control systems for 250°C for 4 hours or 525°C for 15 minutes. Twin City Fan & Blower certifies that the Models QSL, QSLR and QSLSH Mixed Flow Fans shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. See Catalogue 1061 for sound ratings.
2
TWIN CITY FAN - CATALOGUE M1060
Model QSL is available with the UL/CUL 705 listing for electrical, File No. E158680. Model QSLR is UL/CUL 762 listed for the exhaust of grease-laden air as standard, File No. MH-25478. Model QSLSH is UL/CUL listed for Smoke Control Systems as standard, File No. MH-29313, 250°C for 4 hours and 525°C for 15 minutes.
CONSTRUCTION FEATURES
Housings
All fans are constructed of heavy-gauge steel and continuously welded for strength and rigidity. All QSL fans are provided with punched inlet and outlet flanges as standard.
Impeller
The QSL impeller is designed with true aerofoil (double surface - hollow) die-formed, continuously-welded blades for a stable air performance throughout the operating range. The impeller is statically and dynamically balanced prior to assembly and rechecked for balance after assembly by Twin City Fan & Blower.
QSL Impeller
Belt Guard
Totally enclosed, sealed belt guard is standard on Model QSL. Totally enclosed, non-sealed belt guard is standard on Models QSLR and QSLSH.
Inner Cylinder
The inner tube is rigidly constructed to support the shaft and bearings. The removable discharge cone provides full access to the shaft, bearings, and fan sheave. It is strongly recommended that an access door be provided in the ductwork adjacent to the discharge end of the fan for such service.
Bearings
Standard bearings are selected to exceed the L-10 life of 40,000 hours at the maximum operating speed.
Drives
V-belt drives or direct drive fans with motors and drives mounted by Twin City Fan Companies are test run as a complete assembly and rechecked for balance.
Straightening Vanes
Straightening vanes convert tangential velocity pressure into useful static pressure, reducing turbulence and increasing efficiency. Extensive testing of various shapes and locations has resulted in the most efficient aerodynamic design of the straightening vanes.
Extended Lube Lines
Allow for ease of lubrication on all sizes.
Motor Mounting Platform
A heavy-duty motor mounting platform pivots to offer easy and positive adjustment of belt tension. The motor mounting platform is offered in eight standard locations to allow for motor accessibility and space requirements.
Shaft
Shaft diameter sized so that maximum operating speed does not exceed 70% of first critical speed.
EASY ACCESS DESIGNS Clamshell Design
Two clamshell style doors swing open wide to provide complete access to the interior of the fan for maintenance or cleaning without removal of ductwork. Heavy duty hinges, positive locking latches, and a full gasket provides a complete seal when doors are closed. An access door provides access to the bearings. Available on all fan sizes, typically vertical mount.
Swing-out Design
Provides full access to the impeller and inner casing. The entire impeller/shaft/bearing assembly is mounted on a large swing-out door. Ideal for systems requiring frequent cleaning without removal of ductwork. Swingout construction is available for vertical mounting only. Available on sizes 182 and larger.
WWW.TCF.COM
3
MOUNTING CONFIGURATIONS
Horizontal Construction
Vertical Construction
Horizontal construction is available in sizes 150 to 730.
Vertical construction is available in sizes 150 to 542. Consult factory for larger sizes.
Horizontal Base Mounted (HBM) — Support legs are provided at each end of the fan for floor mounting.
Floor or Ceiling Mounted (VUI/VUO/VDI/VDO) — Four vertical brackets are welded to either end of the fan housing. Bracket location is determined by airflow direction and support details (see drawing below).
Horizontal Ceiling Hung (HCH) — For duct mounted fans, four suspension clips are welded to the fan casing to allow ceiling suspension using rod hangers.
Roof Mounted (VRM) — A curb cap provides weathertight seal for roof curb mounted fans. A discharge cap and weather cover are also available for the up-blast style roof ventilator.
Horizontal (HOR) — For mounting configurations where support legs and suspension clips are not required.
Vertical (VUN/VDN) — For mounting configurations where support brackets are not required.
Discharge Arrangements A H
HCH Horizontal Ceiling Hung
A B
G
C
HBM Horizontal Base Mounted
H G
D
F
B C
HOR Horizontal No Mounting Brackets
E NOTE: Horizontal motor positions shown from oulet end.
↑
AIRFLOW
↑
VRM Vertical Roof Mounted
↑
AIRFLOW
AIRFLOW
AIRFLOW
↓
AIRFLOW
VUI Vertical Discharge Up, Floor Mount Support Brackets On Inlet
VUO Vertical Discharge Up,Ceiling Hung Support Brackets On Outlet
VDI Vertical Discharge Down, Ceiling Hung Support Brackets On Inlet
VDO Vertical Discharge Down, Floor Mount Support Brackets On Outlet
↓
Available Discharges by Model
↑
AIRFLOW
AIRFLOW
↓
VUN Vertical Up No Brackets
4
VDN Vertical Down No Brackets
TWIN CITY FAN - CATALOGUE M1060
QSL
QSLSH
QSLR
HBM
HBM
HBM
HCH
HCH
HCH
HOR
HOR
HOR
VDI
N/A
N/A
VDN
N/A
N/A
VDO
N/A
N/A
VUI
VUI
VUI
VUN
VUN
VUN
VUO
VUO
VUO
VRM
VRM
VRM
OPTIONS/ACCESSORIES
Belt Tube
A belt tube encloses the belts and drive components, protecting them from the airstream.
Support Legs — Horizontal Flow
For horizontal flow with floor mounting, support legs are welded to the fan flange with bolt holes aligned for connection of ductwork.
Support Legs — Vertical Flow
For vertical flow with either floor or ceiling mounting, support legs are welded to the fan housing for four-point support.
Suspension Clips
Support Legs, Horizontal
Support Legs, Vertical
Suspension Clips, Horizontal
Discharge Cap
Curb Cap
Shaft Seal
Inlet/Outlet Screens
Companion Flange
For horizontal flow with ceiling mounting, four clips of formed angle are welded to the fan housing for suspension via tie rods to the ceiling support structure.
Inlet and Outlet Screens
Safety screening can be provided for installation in the fan inlet or fan outlet.
Discharge Cap
Discharge caps are designed for vertical, rooftop discharge with butterfly type dampers to seal out the weather when the fan is shut off.
Curb Cap
Attached to the fan’s flange for curb mounting.
Shaft Seal
To limit the air entering the inner cylinder and avoid contact of airstream contaminants with the bearings and V-belt drive. Consists of a Teflon wear pad/plate and a rubber check-seal at the impeller end of the inner cylinder. Please note that a shaft seal does not make the inner cylinder gas tight.
Weather Cover
For outdoor installations, the weather cover completely encloses the motor and V-belt drive from the elements. Provided with slots for ventilation. Weather covers are available for either horizontal or vertical flow fans.
Companion Flanges
Flanges are rolled angle rings, drilled to match the fan’s inlet or outlet flange.
Spark-Resistant Construction
Various grades of spark resistance are as dictated by AMCA: Types A, B, and C (for ATEX, please enquire). Spark resistant construction requires the addition of a sealed belt tube.
Vibration Isolation
Spring or rubber-in-shear isolators as an option. Spring isolators can be provided for floor mount or ceiling hung orientation.
Seismic Certification
Models QSL, QSLR and QSLSH have been seismically tested and certified with the California Office of Statewide Health, Planning and Development (OSHPD) per OSP0271-10. Seismic certification is limited to certain product options and configurations.
WWW.TCF.COM
5
QSLR/QSLSH FANS
QSLR Restaurant Fans
QSLSH Smoke & Heat Fans
Model QSLR is CULUS 762 listed for exhaust of greaseladen air. QSLR is licensed to bear the AMCA certified ratings seal for sound and air performance.
Model QSLSH is CULUS 705 listed and CULUS listed for smoke control systems for 250°C for 4 hours or 525°C for 15 minutes. Vertical roof mounted configuration, with discharge cap, meets UL 793 Snow Load Test requirements for butterfly dampers. QSLSH is licensed to bear the AMCA certified ratings seal for sound and air performance.
Twin City Fan Companies offers a specially modified version of the QSL fan designated as "QSLR" (Mixed Flow Restaurant Exhaust) for exhausting grease-laden air from kitchens, restaurants, cooking and dishwasher hoods. QSLR is available in sizes 150 to 730.
The QSLR fan is available in all configurations with the exception of vertical down (VDN, VDO and VDI).
Standard Product Features
• Belt guard, totally enclosed, ventilated (weather cover for VRM) • Belt tube, sealed • Two cleanout doors located 180° apart (90° from motor) • 50 mm drain located 180° from motor (lowest point for horizontal) vertical at the funnel • Cooling fins on impeller • Housing sealed with Hi-Temp caulk
Twin City Fan Companies offers a specially modified version of the QSL fan designated as "QSLSH" (Mixed Flow Smoke and Heat Exhaust) for smoke control applications where temperatures can reach 525°C. QSLSH is available in sizes 150 to 730.
The QSLSH fan is available in all configurations with the exception of vertical down (VDN, VDO and VDI).
Standard Product Features • • • • • •
Belt guard, ventilated (weather cover for VRM) Belt tube, sealed Two-groove drive minimum w/2.0 SF Cooling fins on impeller Stack cap with fusible link (for VRM) Continuously welded housing
DISCHARGE CAP (OPTIONAL)
AIR FLOW
(2) CLEANOUT DOORS 90 FROM MOTOR 180 FROM EACH OTHER (STANDARD ON QSLR ONLY) O
O
2“ GREASE DRAIN 180 FROM MOTOR (STANDARD ON QSLR ONLY)
WEATHER COVER (STANDARD)
O
GREASE BOX (OPTIONAL ON QSLR ONLY)
6
TWIN CITY FAN - CATALOGUE M1060
CURB CAP (OPTIONAL)
CURB BASE (OPTIONAL)
OPTIONS & ARRANGEMENTS
Insulated Enclosure
To further reduce case radiated sound and motor noise, an optional Insulated Enclosure is available. The enclosure consists of a box with 50 mm thick, dual density fiberglass. Consult the factory for dimensions and sound reduction values.
AIR FLOW
Arrangement 4 (Direct Drive)
Where space constraints require the use of a complete "in line" fan or the desire is for a simple, dependable fan with minimum maintenance requirements, the direct drive Arrangement 4 QSL is available. Constructed with the fan impeller mounted directly on the motor shaft, this fan provides premium efficiency with minimal obstructions in the airstream. The use of a variable frequency drive (VFD) may be necessary for some applications.
AIR FLOW
FAN SIZE
Arrangement 3
Where space is a premium, the QSL arrangement 3 is available to shorten the overall fan length. The table on the right shows the overall savings in length versus an arrangement 9 fan.
182 200 222 245 270 300 330 365 402 445 490 542
ARR. 3 OVERALL LENGTH (TA) 679 732 784 862 927 1038 1141 1256 1379 1500 1627 1813
LENGTH SAVINGS (mm) 181 213 235 264 313 348 379 430 475 556 633 695
AIR FLOW
WWW.TCF.COM
7
ENGINEERING DATA
Table 1. Maximum RPM, Impeller Weights, and WR2 (moment of inertia in kg-m2) FAN SIZE 150 165 182 200 222 245 270 300 330 365 402 445 490 542 600 660 730
MAX. RPM 2721 2483 2232 2027 1839 1655 1505 1360 1234 1116 1013 915 828 752 680 615 558
CLASS I WEIGHT kg 10.9 14.5 17.3 21.8 25.9 31.4 37.3 63.6 75.9 106 147 179 217 269 325 394 484
WR2 (kg-m2) 0.23 0.34 0.51 0.84 1.22 1.90 2.78 5.61 8.30 13.5 24.8 37.2 55.7 81.5 122 183 270
MAX. RPM 3558 3247 2918 2650 2405 2165 1968 1779 1613 1459 1325 1197 1082 984 890 804 730
CLASS II WEIGHT kg 12.7 16.4 20.0 23.6 28.2 34.1 40.9 68.2 81.4 112 147 179 217 269 325 394 484
Table 2. Bare Fan Weights (kg)
WR2 (kg-m2) 0.30 0.43 0.63 0.97 1.43 2.19 3.20 6.11 9.06 14.6 24.8 37.2 55.7 81.5 122 183 270
ARRANGEMENT 9
FAN SIZE
CLASS I
CLASS II
150 165 182 200 222 245 270 300 330 365 402 445 490 542 600 660 730
76 92 98 117 138 167 197 300 365 463 606 725 906 1138 1366 1764 2145
80 96 103 121 143 171 205 314 373 476 617 740 913 1153 1379 1809 2163
2400
2800
3500
4500
75.62 0.939 0.864 0.772 0.746 0.699 0.647 0.587
71.91 0.893 0.822 0.735 0.71 0.664 0.615 0.558
65.76 0.816 0.752 0.672 0.649 0.608 0.563 0.51
57.73 0.717 0.66 0.59 0.57 0.533 0.494 0.448
Table 3. Temperature and Altitude Density Ratios AIR TEMP °C -40 -20 10 20 40 65 100
0
300
600
900
101.32 1.258 1.158 1.035 1 0.936 0.867 0.786
97.77 1.214 1.117 0.999 0.965 0.903 0.837 0.758
94.32 1.171 1.078 0.963 0.931 0.871 0.807 0.732
90.97 1.129 1.04 0.929 0.898 0.84 0.778 0.706
ALTITUDE IN METRES ABOVE SEA LEVEL 1200 1500 1750 2000 BAROMETRIC PRESSURE IN kPa 87.71 84.55 81.99 79.49 1.089 1.05 1.018 0.987 1.002 0.966 0.937 0.909 0.896 0.864 0.838 0.812 0.866 0.835 0.809 0.785 0.81 0.781 0.757 0.734 0.751 0.724 0.702 0.68 0.68 0.656 0.636 0.617
Table 5. Minimum m3/sec Required to Open Discharge Cap
Table 4. Bearing Specifications FAN SIZE 150 165 182 200 222 245 270 300 330 365 402 445 490 542 600 660 730
CLASS I SHAFT DIA. mm.) 25 25 25 30 30 38 38 38 42 50 50 50 55 60 70 75 75
CLASS II
HORIZ.
VERT.
SDB SDB SDB SDB SDB SDB SDB HDB HDB HDB HDB HDB HDB HDB HDB HDB HDB
SDB SDB SDB SDB SDB SDB SDB HDB HDB HDB RB RB RB RB — — —
SHAFT DIA. (mm.) 30 38 38 38 38 42 42 50 55 55 55 65 65 70 75 90 100
HORIZ.
VERT.
SDB SDB HDB HDB HDB HDB HDB HDB HDB RB RB RB RB RB RB RB RB
SDB SDB HDB HDB HDB HDB RB RB RB RB RB RB RB RB — — —
NOTES: 1. BEARINGS CODES: SDB — Standard-Duty Ball such as Dodge SCAH or SKF SY Series HDB — Heavy-Duty Ball such as Dodge SCMAH or SKF SYM Series RB — Roller Bearing such as Dodge S2000 or SKF SYR Series 2. Standard bearings are selected to exceed L-10 life of 40,000 hours at the maximum operating speed.
8
TWIN CITY FAN - CATALOGUE M1060
FAN SIZE 150 165 182 200 222 245 270 300 330 365 402 445 490 542
m3/sec 0.5 0.8 1.2 1.7 1.7 2.2 3.1 3.6 4.1 5.3 7.5 7.5 9.9 12.6
PERFORMANCE CURVES QSL 150 10
3500 RPM 90
2,000
A Lw
7 2850 RPM
1,500
85
5
A Lw
2500 RPM 1,000
A Lw
2000 RPM
1450 RPM
2.2kW
A
Lw
1.5kW 1.1kW
200
Lw
0.75kW
A
0.7
400
70
1
3kW
A Lw
1.5
4kW 75
2
PF - Fan Total Pressure (Pa)
600
65
960 RPM 150
0.55kW 60 A
Lw
0.5 100
0.25kW
%
A
Eff
.
Lw ff. .E
0.18kW
Pk
0.3
80
0.37kW
55
720 RPM 64
%
60
68
Eff .
0.2 %
40
56
PF - Fan Total Pressure (in W.G.)
5.5kW
80
800
3
0.2
0.4
0.7
0.5
1
2
0.7
0.6
3
1
5
0.8
1
qv - Flow (m³ / sec) 7
10
20
1.5
30
Pd - Fan Velocity Pressure (Pa) 1.5
2
3
qv - Flow (CFM) (in Thousands)
2
50
4
70
5
100
200
7
Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
9
PERFORMANCE CURVES QSL 165
2,000
2850 RPM
7 1,500
90
2500 RPM
A Lw
5 85 A Lw
1,000 2000 RPM 800
3
80 A Lw
A Lw
2.2kW
A
Lw
960 RPM
200
1.1kW A
60 A
Lw
0.55kW
720 RPM .
0.37kW .E
ff.
64
%
Eff
100
Pk
80
%
0.25kW
68
0.3
1.5kW
0.75kW
150 0.5
3kW
Lw
0.7
400
70
1
4kW
1450 RPM 75
1.5
PF - Fan Total Pressure (Pa)
2
65
PF - Fan Total Pressure (in W.G.)
600
0.18kW
Eff
.
60
56
%
0.2 40 0.4
0.6
2
3
1
0.8
5
1.5
1
1.5
2
qv - Flow (m³ / sec) 7
10
20
30
Pd - Fan Velocity Pressure (Pa) 2
3
qv - Flow (CFM) (in Thousands)
4
50
5
70
100
7
Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7.
10
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES QSL 182 10
2850 RPM 2,000 90
2500 RPM
7
A Lw
1,500 5
2000 RPM 85
1,000
A Lw
800
3
1.5kW
200
1.1kW
A
Lw
PF - Fan Total Pressure (Pa)
2.2kW
A Lw
960 RPM
150
720 RPM
0.75kW Lw
0.55kW
A
55
100
0.37kW
A
Lw
0.25kW
%
Pk
0.2
0.18kW
ff.
%
Eff
.
60
.E
0.3
80 500 RPM 64
40
56 %
Eff
.
68
PF - Fan Total Pressure (in W.G.)
A Lw
3kW
60
0.5
4kW
65
0.7
400
70
1
5.5kW
75
1.5
1450 RPM
A Lw
2
7.5kW
80
600
0.1 20 0.4
0.6
1
2
1
0.8
3
1.5
1
5
1.5
2
4
qv - Flow (m³ / sec) 7
10
20
30
Pd - Fan Velocity Pressure (Pa) 2
3
5
qv - Flow (CFM) (in Thousands)
50
70
7
6
100
200
10
Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
11
PERFORMANCE CURVES QSL 200 10 2500 RPM
2,000 7
90
2000 RPM
5
A Lw
800
3
1450 RPM 80
4kW
960 RPM
3kW
A
Lw
2.2kW
200 720 RPM
1.5kW A
PF - Fan Total Pressure (Pa)
A Lw
400
Lw
0.7
5.5kW
70
1
1.1kW
150 60
0.75kW
A
Lw
0.5
0.55kW
100 500 RPM 80
55 Lw
0.37kW
.E
0.25kW
68 %
Pk
60
ff.
64
%
Eff
.
A
0.3
7.5kW
75
1.5
A Lw
600
65
PF - Fan Total Pressure (in W.G.)
85
1,000
2
A Lw
1,500
0.2
0.18kW
56
%
Eff .
40
0.6
0.8
2
1.5
1
3
1.5
2
4
qv - Flow (m³ / sec) 5
7
10
20
30
Pd - Fan Velocity Pressure (Pa)
2
3
5
qv - Flow (CFM) (in Thousands)
50
7
70
6
100
10
Fan Efficiency Grade = FEG 71 Notes: 1. 2. 3. 4. 5. 6. 7.
12
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES QSL 222
2,000 7
2000 RPM 1,500
5 85 A Lw
1,000
7.5kW
1450 RPM 800 80
3
A Lw
5.5kW A Lw
960 RPM
4kW 3kW
A
Lw
2.2kW
720 RPM
1.5kW
200
Lw
1.1kW
A
0.7
400
70
1
75
1.5
PF - Fan Total Pressure (Pa)
2
65
150 0.75kW
60 A
Lw
0.5
0.55kW
Eff
.
500 RPM 100 %
0.37kW . Eff
0.25kW
Pk .
0.3
80
69
60
74 %
0.18kW
%
Eff .
0.2 40
66
PF - Fan Total Pressure (in W.G.)
600
0.8
1
2
1.5
1.5
3
2
5
2
4
qv - Flow (m³ / sec) 7
10
20
30
Pd - Fan Velocity Pressure (Pa) 3
5
7
qv - Flow (CFM) (in Thousands)
6
50
70
100
10
Fan Efficiency Grade = FEG 75 Notes: 1. 2. 3. 4. 5. 6. 7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
13
PERFORMANCE CURVES QSL 245 10 2000 RPM
2,000 7
90 A Lw
1,500 5 85
1450 RPM
A Lw
960 RPM
A
Lw
400
4kW 3kW
A
720 RPM
2.2kW
200
1.5kW
A
Lw
0.7
1.1kW 60
150 500 RPM
A
Lw
0.75kW Eff
.
0.5
5.5kW
Lw
PF - Fan Total Pressure (Pa)
80
7.5kW
70
1
600
75
1.5
11kW
65
PF - Fan Total Pressure (in W.G.)
800
3
2
A Lw
1,000
%
100
Pk
80
%
0.37kW
75
0.3
.E
ff.
69
0.55kW
0.25kW
1
2
67 %
Eff .
60 1.5
3
2
2
5
3
7
qv - Flow (m³ / sec) 10
20
4
6
30
50
Pd - Fan Velocity Pressure (Pa) 5
7
qv - Flow (CFM) (in Thousands)
10
70
8
100
15
Fan Efficiency Grade = FEG 75 Notes: 1. 2. 3. 4. 5. 6. 7.
14
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES QSL 270
1,500
1450 RPM
5 1,000
85 A Lw
800
3
7.5kW 80
960 RPM
A Lw
5.5kW
A Lw
720 RPM
4kW
3kW
70 A
Lw
1
400
75
1.5
PF - Fan Total Pressure (Pa)
2
2.2kW
200
65 Lw
0.7
A
1.5kW
500 RPM
1.1kW
Eff
.
150
%
0.5
ff.
69
.E
0.75kW
Pk
100
75 %
0.55kW
%
Eff .
0.3
80
60
66
PF - Fan Total Pressure (in W.G.)
600
1
1.5
2
3
3
2
5
0.37kW
qv - Flow (m³ / sec) 7
10
4
6
20
Pd - Fan Velocity Pressure (Pa) 5
7
qv - Flow (CFM) (in Thousands)
30
10
50
8
70
100
15
Fan Efficiency Grade = FEG 75 Notes: 1. 2. 3. 4. 5. 6. 7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
15
PERFORMANCE CURVES QSL 300
2,000 7
1450 RPM 90
1,500
A Lw
5 1,000 85 A Lw
800
3
960 RPM 80
600
500 RPM
3kW
A
Lw
2.2kW
150
1.5kW 1.1kW
A
Lw
PF - Fan Total Pressure (Pa)
A Lw
200
100
0.75kW
55
PF - Fan Total Pressure (in W.G.)
A Lw
4kW
60
0.5
5.5kW
65
0.7
7.5kW
70
1
720 RPM
400
75
1.5
Lw
80
A
0.3
11kW
A Lw
2
0.55kW
300 RPM .
60
%
Eff
0.37kW
.E
ff.
69
0.2
Pk
0.25kW
75
%
40
66
%
Eff
.
0.18kW
0.1 20
1
1.5
1
2
3
2
3
4
qv - Flow (m³ / sec) 5
7
10
20
6
8
30
50
Pd - Fan Velocity Pressure (Pa) 5
7
10
qv - Flow (CFM) (in Thousands)
15
10
70
20
15
100
30
Fan Efficiency Grade = FEG 75 Notes: 1. 2. 3. 4. 5. 6. 7.
16
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES QSL 330
2,000
1450 RPM
7 1,500 90 A Lw
5 1,000 A Lw
3
75
400
A Lw
7.5kW 5.5kW
70 Lw
200
4kW
A
500 RPM
3kW A
Lw
PF - Fan Total Pressure (Pa)
11kW
2.2kW
150 60
0.5
1.5kW
A
Lw
1.1kW
100 55
0.75kW
Eff
.
A
Lw
0.55kW
%
0.3
300 RPM
80
69
Pk .
Eff
.
60 0.2
0.37kW
75 %
40 %
Eff .
0.25kW
66
PF - Fan Total Pressure (in W.G.)
720 RPM
65
0.7
15kW
A Lw
2
1
18.5kW
80
600
1.5
85
960 RPM
800
1
1.5
0.7
1
2
2
3
4
6
8
qv - Flow (m³ / sec) 3
5
7
10
20
30
Pd - Fan Velocity Pressure (Pa) 5
7
10
15
qv - Flow (CFM) (in Thousands)
10
50
20
15
70
100
20
200
30
Fan Efficiency Grade = FEG 75 Notes: 1. 2. 3. 4. 5. 6. 7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
17
PERFORMANCE CURVES QSL 365 10
1450 RPM 2,000 95
7
A Lw
1,500
37kW 90
5
A Lw A Lw A Lw
11kW
500 RPM
7.5kW Lw A
5.5kW
200
4kW A
3kW
150
2.2kW
60
0.5
A
Lw
300 RPM 100
1.1kW
Pk
.E
ff.
72
A
%
80
Lw
Eff
.
1.5kW 55
0.3
80
15kW
400
Lw
0.7
22kW 18.5kW
70
1
720 RPM
75
1.5
PF - Fan Total Pressure (Pa)
600
30kW
65
PF - Fan Total Pressure (in W.G.)
85
800
3
2
A Lw
960 RPM
1,000
0.75kW
76
%
60 0.2
Eff .
0.55kW 65 %
40
2
0.37kW
4
2
3
5
5
7
6
8
10
15
qv - Flow (m³ / sec) 7
10
20
30
50
Pd - Fan Velocity Pressure (Pa) 10
15
20
qv - Flow (CFM) (in Thousands)
70
30
100
20
200
300
50
Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7.
18
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES QSL 402
1,500
960 RPM
5 1,000
85
800
A Lw
3
720 RPM 600 80 A Lw
2
A
Lw
7.5kW
5.5kW
200 4kW
A
PF - Fan Total Pressure (Pa)
A Lw
11kW
Lw
0.7
500 RPM
70
1
400 75
1.5
65
150 3kW
300 RPM
60 Lw
0.5
Eff
.
A
2.2kW
%
100
.E
ff.
72
Pk
1.5kW
%
0.3
80
76
1.1kW
Eff .
60 0.75kW
65 %
PF - Fan Total Pressure (in W.G.)
15kW
0.2
0.55kW
40
4
3
7
6
5
7
10
8
qv - Flow (m³ / sec)
10
20
10
15
30
Pd - Fan Velocity Pressure (Pa) 15
20
qv - Flow (CFM) (in Thousands)
50
20
70
100
30
Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
19
PERFORMANCE CURVES QSL 445
2,000 7
960 RPM
1,500 5
90 A Lw
1,000 720 RPM A Lw
3
85
800 600
80
Lw A
300 RPM
150
4kW 3kW
A
100
2.2kW Lw
80
A
1.5kW
200 RPM
1.1kW
%
Eff
.
60
72
0.2
ff.
PF - Fan Total Pressure (Pa)
5.5kW
Lw
PF - Fan Total Pressure (in W.G.)
A Lw A Lw
7.5kW
200
55
0.3
11kW
60
0.5
15kW
65
0.7
18.5kW
70
1
22kW
500 RPM
400
75
1.5
A Lw
2
Pk
.E
0.75kW
%
40
Eff .
76
0.55kW
65 %
0.37kW
0.1
0.25kW
20
2
4
1
2
5
7
3
6
8
10
15
qv - Flow (m³ / sec) 5
7
10
20
30
50
Pd - Fan Velocity Pressure (Pa) 10
15
20
qv - Flow (CFM) (in Thousands)
20
30
70
100
50
Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7.
20
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES QSL 490
2,000 7
960 RPM 95 A Lw
1,500 5 90
720 RPM
A Lw
1,000
45kW 85
800
A Lw
3
600
11kW A
Lw
200
7.5kW
300 RPM
5.5kW
A
PF - Fan Total Pressure (Pa)
A Lw A Lw
15kW
Lw
150
4kW 60
0.5
Lw
200 RPM
2.2kW
55 Eff
.
A
Lw
1.5kW
%
0.3
80
3kW
A
100
Pk
.E
60
ff.
72
1.1kW
%
0.2
76
0.75kW Eff
.
40 %
0.55kW
65
PF - Fan Total Pressure (in W.G.)
80
22kW 18.5kW
65
0.7
400
70
1
30kW
75
1.5
37kW
500 RPM
2
4
6
2
7
3
10
8
5
7
10
15
20
qv - Flow (m³ / sec) 10
20
30
Pd - Fan Velocity Pressure (Pa) 15
20
30
qv - Flow (CFM) (in Thousands)
50
70
100
50
70
Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
21
PERFORMANCE CURVES QSL 542 10
960 RPM 2,000
7 95 A Lw
1,500 720 RPM
5
75kW 90 A Lw
1,000 800
15kW
300 RPM
A
11kW
200 7.5kW
Lw
PF - Fan Total Pressure (Pa)
A Lw A Lw
22kW 18.5kW
Lw
0.7
30kW
400
70
1
45kW 37kW
75
1.5
A
150
5.5kW
0.5 60
4kW
Lw A
100 200 RPM Eff
.
3kW
%
80
2.2kW
Pk
.E
ff.
72
0.3
55kW
80
2
A Lw
500 RPM
600
65
PF - Fan Total Pressure (in W.G.)
85
3
%
60
76
1.5kW
0.2 Eff
.
1.1kW
65
%
40
4
2
6
8
3
5
10
15
0.75kW
10
7
15
qv - Flow (m³ / sec) 10
20
20
30
Pd - Fan Velocity Pressure (Pa) 20
30
qv - Flow (CFM) (in Thousands)
40
50
50
70
100
70
200
100
Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7.
22
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES QSL 600
2,000 7
720 RPM
1,500 5
90
800
500 RPM 85
3
A Lw
600
A Lw
200
11kW Lw
150
A
7.5kW
200 RPM
5.5kW A
PF - Fan Total Pressure (Pa)
A Lw
15kW
Lw
100
4kW
80
3kW
Lw A
150 RPM
2.2kW %
Eff
.
60
1.5kW
Pk
.E
0.2
ff.
72
1.1kW
%
40
76
Eff
.
0.75kW
65 %
PF - Fan Total Pressure (in W.G.)
A Lw
75
18.5kW
55
0.3
22kW
300 RPM
60
0.5
30kW
65
0.7
37kW
400
70
1
45kW
80
2 1.5
55kW
A Lw
1,000
0.1 20
4
6
1
8
2
10
3
15
0.55kW
10
5
15
qv - Flow (m³ / sec) 7
10
20
40
20
Pd - Fan Velocity Pressure (Pa) 20
30
qv - Flow (CFM) (in Thousands)
30
50
50
70
70
100
100
Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
23
PERFORMANCE CURVES QSL 660
2,000
720 RPM
7 95
1,500
A Lw
5
90kW 90
1,000
A Lw
500 RPM
800
3
85 A Lw
600
75
300 RPM
A Lw
30kW 22kW 18.5kW
A
Lw
0.7
37kW
70
1
200 200 RPM
11kW A
150
15kW
Lw
PF - Fan Total Pressure (Pa)
A Lw
1.5
45kW
400
65
PF - Fan Total Pressure (in W.G.)
55kW
80
2
75kW
7.5kW
0.5 60 A
150 RPM 80
.E
ff.
72
%
A
60
3kW
Lw
Eff
.
4kW 55
0.3
5.5kW
Lw
100
%
Pk
2.2kW
76
0.2
1.5kW Eff .
40
65
%
1.1kW
6
8
2
10
3
15
20
15
20
40
qv - Flow (m³ / sec)
5
7
10
20
30
Pd - Fan Velocity Pressure (Pa) 30
50
70
qv - Flow (CFM) (in Thousands)
50
60
70
100
100
Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7.
24
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
TWIN CITY FAN - CATALOGUE M1060
PERFORMANCE CURVES QSL 730 10
720 RPM 2,000
7 95
1,500
A Lw
5
500 RPM 132kW
90
1,000
A Lw
800
3
A Lw
55kW 45kW 37kW
Lw A
30kW 22kW
70
18.5kW
Lw
200
A
0.7
300 RPM
400
75
1
A Lw
1.5
90kW 75kW
80
2
PF - Fan Total Pressure (Pa)
600
200 RPM
15kW
150
65
11kW
A
Lw
0.5 7.5kW
60 A
Lw
100 150 RPM Eff
.
5.5kW
80
%
.E
ff.
4kW
Pk
0.3
72
3kW
%
60
76
0.2 Eff
.
2.2kW %
40
65
PF - Fan Total Pressure (in W.G.)
85
110kW
8
10
2
15
20
1.5kW
15
3
5
30
20
40
qv - Flow (m³ / sec) 7
10
20
30
Pd - Fan Velocity Pressure (Pa) 50
70
qv - Flow (CFM) (in Thousands)
60
50
100
70
80
100
150
Fan Efficiency Grade = FEG 80 Notes: 1. 2. 3. 4. 5. 6. 7.
Performance certified is for Installation Type B & D: Free or ducted inlet, ducted outlet. Power rating (kW) does not include transmission losses. Performance ratings do not include the effects of appurtenances (accessories). The sound power level ratings shown are in decibels, referred to 10 E-12 watts calculated per AMCA Standard 301. Values shown are for inlet LwiA sound power levels for Installation Type B: Free inlet, ducted outlet. Ratings do not include the effects of duct end correction. The A-weighted sound ratings shown have been calculated per AMCA Standard 301.
WWW.TCF.COM
25
DIMENSIONAL DATA Horizontal
MOTOR "FR" MAX. FRAME
CB
INSIDE
DIA.
CA FLOW
"TH" HSG. GAGE
LOC. A MC MAX
FLANGE
ROTATION
CC O.D.
AIR
B.C.
DUCT
SEALED BELT GUARD STD EXCEPT FOR SPARK RESISTANT CONSTRUCTION
"NH" NUMBER OF "DH" DIA. HOLES ON "CB" DIA. B.C. EQUALLY SPACED STRADDLING CENTER LINE
"SD" DIA. SHAFT
TA
OUTLET END
TYPE "QSL" HORIZONTAL DISCHARGE A
BB D
BD
BN
BE
F
38.1
M
BF
M
HCH
HORIZONTAL BASE MOUNTED
D E
SUSPENSION CLIPS
FOUR "BM" DIA. CLIP HOLES
G
HBM
C
G
SUPPORT LEGS FOUR "BH" DIA. MTG. HOLES
B
H
MOTOR LOCATION VIEWED FROM OUTLET END
HORIZONTAL CEILING HUNG
SIZE
BB
BD
BE
BF
BH
BM
BN
BT
CA
CB
CC
D
DH
FR
G
M
MC
NH
150 165 182 200 222 245 270 300 330 365 405 445 490 542 600 660 730
25 25 38 38 38 38 38 38 38 51 51 51 51 51 64 64 64
655 727 785 868 945 1049 1164 1309 1445 1584 1753 1954 2159 2406 2635 2924 3244
27 27 27 27 33 33 33 33 33 40 43 43 43 62 62 62 62
652 724 807 890 954 1059 1173 1318 1455 1607 1769 1970 2175 2384 2638 2927 3247
11 11 11 14 14 14 14 14 14 21 21 21 21 21 21 27 27
14 14 14 14 14 21 21 21 21 21 21 21 21 27 27 27 27
597 657 705 765 842 921 1007 1111 1216 1335 1462 1610 1764 1945 2169 2376 2615
165 165 165 184 203 227 248 278 305 337 375 413 457 505 562 616 683
514 567 627 687 764 842 927 1030 1134 1254 1381 1529 1683 1864 2062 2268 2508
562 619 679 740 816 892 978 1096 1200 1321 1461 1607 1762 1956 2153 2359 2651
594 654 711 770 848 924 1010 1140 1245 1365 1518 1664 1819 2026 2223 2429 2721
356 381 406 457 508 533 584 635 686 737 838 914 991 1092 1194 1321 1448
14 18 18 21 21 21 21 21 21 21 21 21 21 21 21 21 21
132M 132M 160L 160L 160L 180L 180L 200L 200L 225M 225M 250M 250M 280M 280M 280M 280M
594 654 711 770 848 924 1010 1140 1245 1365 1518 1664 1819 2026 2223 2429 2721
259 286 318 347 386 424 467 532 584 645 721 794 871 975 1073 1178 1322
654 706 875 919 956 960 1071 1146 1183 1308 1518 1580 1719 1818 1993 2102 2229
8 8 12 12 12 12 12 16 16 16 16 16 24 24 24 24 24
SD CL I CL II 25 30 25 35 25 35 30 35 30 35 35 42 35 42 35 50 42 55 50 55 50 55 50 65 55 65 65 70 70 75 75 90 75 100
TA
TH
706 778 861 944 1021 1125 1240 1385 1521 1686 1854 2055 2260 2507 2762 3051 3372
10 10 12 12 12 12 12 10 10 10 10 10 10 10 10 10 10
QSL-AC1000023E QSLR-AC1001672A QSLSH-AC1001666B
DIMENSIONS ARE SUBJECT TO CHANGE. CERTIFIED DRAWINGS AVAILABLE ON REQUEST.
26
TWIN CITY FAN - CATALOGUE M1060
DIMENSIONAL DATA Vertical
O.D.
CC CB
DIA. INSIDE
CA
FLANGE B.C.
“BT” BELT TUBE WIDTH
DUCT
38.1
(4) 14.224 DIA. MTG. HOLES
NOTE 1 BL
101.6 45ø 50.8
"SD" DIA. SHAFT TA
NOTE 1
ROTATION
MOTOR "FR" MAX. FRAME
"TH" HOUSING GAGE SUPPORT LEGS FOUR PLACES (NOTE 2)
45ø
"NH" NUMBER OF "DH" DIA. HOLES ON "CB" DIA. B.C. EQUALLY SPACED STRADDLING CENTER LINE
AIR FLOW
MC MAX
VIEWED FROM OUTLET END TYPE "QSL" VERTICAL UP DISCHARGE WITH FLOOR MOUNT SUPPORT LEGS
AIR FLOW
AIR FLOW
VUI
AIR FLOW NOTES: 1. One locking collar and impeller hub cap included to prevent shifting of components. 2. Support legs shown are provided as an accessory.
AIR FLOW
DISCHARGE UP FLOOR MOUNT
UP VUO DISCHARGE CEILING HUNG
VDI
DISCH. DOWN CEILING HUNG
DOWN VDO DISCH. FLOOR MOUNT
SIZE
BL
BT
CA
CB
CC
DH
FR
MC
NH
150 165 182 200 222 245 270 300 330 365 402 445 490 542
645 710 838 899 965 1051 1137 1267 1372 1492 1645 1791 1946 2153
165 165 165 184 203 227 248 278 305 337 375 413 457 505
514 567 627 687 764 842 927 1030 1134 1254 1381 1529 1683 1864
562 619 679 740 816 892 978 1096 1200 1321 1461 1607 1762 1956
594 654 711 770 848 924 1010 1140 1245 1365 1518 1664 1819 2026
14 18 18 21 21 21 21 21 21 21 21 21 21 21
132M 132M 160L 160L 160L 180L 180L 200L 200L 225M 225M 250M 250M 280M
654 704 875 919 956 962 1071 1146 1183 1308 1518 1580 1719 1816
8 8 12 12 12 12 12 16 16 16 16 16 24 24
SD CLI 25 25 25 30 30 35 35 35 42 50 50 50 55 65
CLII 30 35 35 35 35 42 42 50 55 55 55 65 65 70
TA
TH
705 771 861 945 1021 1125 1240 1386 1521 1686 1854 2056 2235 2507
10 10 12 12 12 12 12 10 10 10 10 10 10 10
QSL-AC1000024F QSLR-AC1001675B QSLSH-AC1001667C
DIMENSIONS ARE SUBJECT TO CHANGE. CERTIFIED DRAWINGS AVAILABLE ON REQUEST.
WWW.TCF.COM
27
DIMENSIONAL DATA Vertical Roof "NH" NUMBER OF "DH" DIA. HOLES ON "CB" DIA. B.C. EQUALLY SPACED STRADDLING CENTER LINE
O.D. DISCH. CAP CG
"A"
DISCHARGE CAP
O.D.
AIR FLOW
DUCT
"SD" DIA. SHAFT "BT" BELT TUBE WIDTH
CA
NOTE 1 CH
INSIDE
FLANGE
CK
CC
"A"
TA NOTE 1
25.4 MC MAX
"TH" HOUSING GAGE
VIEW "A" - "A" W/O DISCHARGE CAP
MOTOR "FR" MAX. FRAME
CJ
CURB CAP
69.85
CD
50.8
O.D. HSG
CE
INSIDE SQ.
TYPE "QSL" VERTICAL DISCHARGE WITH DISCHARGE CAP AND CURB CAP NOTES: 1. One locking collar and impeller hub cap included to prevent shifting of components. 2. Discharge cap and curb cap are optional accessories.
SIZE
BL
BT
CA
CB
CC
CD
CE
CG
CH
CJ
CK
DH
FR
MC
NH
150 165 182 200 222 245 270 300 330 365 402 445 490 542
645 710 838 899 965 1051 1137 1267 1372 1492 1645 1791 1946 2153
165 165 165 184 203 227 248 278 305 337 375 413 457 505
514 567 627 687 764 842 927 1030 1134 1254 1381 1529 1683 1864
562 619 679 740 816 892 978 1096 1200 1321 1461 1607 1762 1956
594 654 711 770 848 924 1010 1140 1245 1365 1518 1664 1819 2026
521 573 632 692 768 846 932 1037 1140 1261 1388 1535 1689 1870
695 784 886 949 1026 1102 1187 1295 1400 1521 1648 1769 1981 2254
762 813 864 1016 1016 1168 1168 1346 1499 1524 1702 1854 2032 2197
1238 1395 1486 1649 1726 1913 2034 2268 2480 2645 2896 3186 3505 4002
152 160 168 171 171 178 184 197 197 197 203 216 229 235
381 457 457 533 533 610 610 686 762 762 838 914 1016 1261
14 18 18 21 21 21 21 21 21 21 21 21 21 21
132M 132M 160L 160L 160L 180L 180L 200L 200L 225M 225M 250M 250M 280M
654 704 875 919 956 962 1071 1146 1183 1308 1518 1580 1719 1816
8 8 12 12 12 12 12 16 16 16 16 16 24 24
SD CLI 25 25 25 30 30 35 35 35 42 50 50 50 55 65
CLII 30 35 35 35 35 42 42 50 55 55 55 65 65 70
TA
TH
705 771 861 945 1021 1125 1240 1386 1521 1686 1854 2056 2235 2507
10 10 12 12 12 12 12 10 10 10 10 10 10 10
QSL-AC1000567B QSLR-AC1001673B QSLSH-AC1001674B
DIMENSIONS ARE SUBJECT TO CHANGE. CERTIFIED DRAWINGS AVAILABLE ON REQUEST.
28
TWIN CITY FAN - CATALOGUE M1060
TYPICAL SPECIFICATIONS
Model QSL
Fans shall be Type QSL (standard mixed flow) of the non-overloading design, as manufactured by Twin City Fan Companies. PERFORMANCE — Performance ratings shall conform to AMCA Standard 205 (fan efficiency grade), 211 (air performance) and 311 (sound performance). Fans shall be tested in accordance with ANSI/AMCA Standard 210 (air performance) and 300 (sound performance) in an AMCA accredited laboratory. Fans shall be licensed to bear the AMCA certified ratings seal for both sound and air, and fan efficiency grade (FEG). Sound certification shall apply to both inlet and outlet sound power levels. Fans shall be designed for maximum efficiency. Fans shall have a sharply rising pressure characteristic extending through the operating range and continuing to rise well beyond the efficiency peak to assure quiet and stable operation under all conditions. Power characteristics shall be truly self-limiting and shall reach a peak in the normal selection area. Model QSL shall be available UL 705 listed. Fans shall bear a permanently attached nameplate displaying model and serial number of the unit for future identification. HOUSING — Housings shall be cylindrical and welded steel throughout. Inlets shall be fully streamlined. Housings shall be suitably braced to prevent vibration or pulsation. Totally enclosed belt guard shall enclose motor sheave and V-belt drives. Punched inlet and outlet flanges shall be equipped for duct mounting. Extended lube lines shall be provided for ease of lubrication. Model QSL shall include bolted access door for inspection and maintenance of impeller. IMPELLER — Fan impellers shall have die-formed hollow aerofoil blades designed for maximum efficiency, and quiet and stable operation. Blades shall be continuously welded to the back plate and impeller cone. Impellers shall be statically and dynamically balanced and the complete fan assembly including motor and drive shall be test balanced at or near the operating speed at the factory prior to shipment. SHAFT — Shafts shall be AISI 1040 or 1045 hot rolled steel, accurately turned, ground, polished, and ring gauged for accuracy. Shafts shall be sized for the first critical speed of at least 1.43 times the maximum speed. BEARINGS — Bearings shall be heavy duty, grease lubricated, anti-friction ball or roller, self-aligning, pillow block type and selected for a minimum L-10 life of 40,000 hours at the maximum fan RPM. Bearings shall be equipped with extended lubrication lines with grease fittings outside of the fan housing. DRIVE — Motor sheaves shall be cast iron, variable pitch on applications 7.5 kW and smaller, and fixed pitch on 11 kW and larger. INLET VANES — Inlet vanes, where specified, shall be of the nested design. Inlet vanes shall be designed for economical, stable, and efficient air volume control at partial load conditions. FINISH AND COATING — The entire fan assembly, excluding the shaft, shall be thoroughly degreased and de-burred before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminum components shall be unpainted. FACTORY RUN TEST — All fans with motors and drives mounted by Twin City Fan & Blower shall be completely assembled and test run as a unit at the specified operating speed prior to shipment. Each impeller shall be statically and dynamically balanced in accordance with ANSI/AMCA 204-96 “Balance Quality and Vibration Levels for Fans” to Fan Application Category BV-3, Balance Quality Grade G6.3. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy shall be available upon request. GUARANTEE — The manufacturer shall guarantee the workmanship and materials for its QSL Mixed Flow Fans for at least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first.
WWW.TCF.COM
29
TYPICAL SPECIFICATIONS
Model
QSLR
Fans shall be Type QSLR (restaurant) of the non-overloading design, as manufactured by Twin City Fan Companies. PERFORMANCE — Performance ratings shall conform to AMCA Standard 205 (fan efficiency grade), 211 (air performance) and 311 (sound performance). Fans shall be tested in accordance with ANSI/AMCA Standard 210 (air performance) and 300 (sound performance) in an AMCA accredited laboratory. Fans shall be licensed to bear the AMCA certified ratings seal for both sound and air, and fan efficiency grade (FEG). Sound certification shall apply to both inlet and outlet sound power levels. Fans shall be designed for maximum efficiency. Fans shall have a sharply rising pressure characteristic extending through the operating range and continuing to rise well beyond the efficiency peak to assure quiet and stable operation under all conditions. Power characteristics shall be truly self-limiting and shall reach a peak in the normal selection area. Model QSLR shall be UL 762 listed for the exhaust of grease-laden air. Fans shall bear a permanently attached nameplate displaying model and serial number of the unit for future identification. HOUSING — Housings shall be cylindrical and welded steel throughout. Inlets shall be fully streamlined. Housings shall be suitably braced to prevent vibration or pulsation. Totally enclosed belt guard shall enclose motor sheave and V-belt drives. Punched inlet and outlet flanges shall be equipped for duct mounting. Extended lube lines shall be provided for ease of lubrication. Model QSLR shall include a belt tube, 2 impeller cleanout doors (located 180° apart) for inspection and maintenance of the impeller and a 2" drain. IMPELLER — Fan impellers shall have die-formed hollow aerofoil blades designed for maximum efficiency, and quiet and stable operation. Blades shall be continuously welded to the back plate and impeller cone. Impellers shall be statically and dynamically balanced and the complete fan assembly including motor and drive shall be test balanced at or near the operating speed at the factory prior to shipment. Impellers on model QSLR shall have cooling fins to draw cool air over shaft and bearings. SHAFT — Shafts shall be AISI 1040 or 1045 hot rolled steel, accurately turned, ground, polished, and ring gauged for accuracy. Shafts shall be sized for the first critical speed of at least 1.43 times the maximum speed. BEARINGS — Bearings shall be heavy duty, grease lubricated, anti-friction ball or roller, self-aligning, pillow block type and selected for a minimum L-10 life of 40,000 hours at the maximum fan RPM. Bearings shall be equipped with extended lubrication lines with grease fittings outside of the fan housing. DRIVE — Motor sheaves shall be cast iron, variable pitch on applications 7.5 kW and smaller, and fixed pitch on 11 kW and larger. INLET VANES — Inlet vanes, where specified, shall be of the nested design. Inlet vanes shall be designed for economical, stable, and efficient air volume control at partial load conditions. FINISH AND COATING — The entire fan assembly, excluding the shaft, shall be thoroughly degreased and de-burred before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminum components shall be unpainted. FACTORY RUN TEST — All fans with motors and drives mounted by Twin City Fan & Blower shall be completely assembled and test run as a unit at the specified operating speed prior to shipment. Each impeller shall be statically and dynamically balanced in accordance with ANSI/AMCA 204-96 “Balance Quality and Vibration Levels for Fans” to Fan Application Category BV-3, Balance Quality Grade G6.3. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy shall be available upon request. GUARANTEE — The manufacturer shall guarantee the workmanship and materials for its QSLR Mixed Flow Fans for at least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first.
30
TWIN CITY FAN - CATALOGUE M1060
TYPICAL SPECIFICATIONS
Model QSLSH
Fans shall be Type QSLSH (smoke and heat) of the non-overloading design, as manufactured by Twin City Fan Companies. PERFORMANCE — Performance ratings shall conform to AMCA Standard 205 (fan efficiency grade), 211 (air performance) and 311 (sound performance). Fans shall be tested in accordance with ANSI/AMCA Standard 210 (air performance) and 300 (sound performance) in an AMCA accredited laboratory. Fans shall be licensed to bear the AMCA certified ratings seal for both sound and air, and fan efficiency grade (FEG). Sound certification shall apply to both inlet and outlet sound power levels. Fans shall be designed for maximum efficiency. Fans shall have a sharply rising pressure characteristic extending through the operating range and continuing to rise well beyond the efficiency peak to assure quiet and stable operation under all conditions. Power characteristics shall be truly self-limiting and shall reach a peak in the normal selection area. Model QSLSH shall be UL listed for Smoke Control Systems ((250°C for 4 hours and 525°C for 15 minutes). Fans shall bear a permanently attached nameplate displaying model and serial number of the unit for future identification. HOUSING — Housings shall be cylindrical and welded steel throughout. Inlets shall be fully streamlined. Housings shall be suitably braced to prevent vibration or pulsation. Totally enclosed belt guard shall enclose motor sheave and V-belt drives. Punched inlet and outlet flanges shall be equipped for duct mounting. Extended lube lines shall be provided for ease of lubrication. Model QSLSH shall include a belt tube for the protection of belts and drive components from the airstream and bolted access door. IMPELLER — Fan impellers shall have die-formed hollow aerofoil blades designed for maximum efficiency, and quiet and stable operation. Blades shall be continuously welded to the back plate and impeller cone. Impellers shall be statically and dynamically balanced and the complete fan assembly including motor and drive shall be test balanced at or near the operating speed at the factory prior to shipment. Impellers on model and QSLSH shall have cooling fins to draw cool air over shaft and bearings. SHAFT — Shafts shall be AISI 1040 or 1045 hot rolled steel, accurately turned, ground, polished, and ring gauged for accuracy. Shafts shall be sized for the first critical speed of at least 1.43 times the maximum speed. BEARINGS — Bearings shall be heavy duty, grease lubricated, anti-friction ball or roller, self-aligning, pillow block type and selected for a minimum L-10 life of 40,000 hours at the maximum fan RPM. Bearings shall be equipped with extended lubrication lines with grease fittings outside of the fan housing. DRIVE — Motor sheaves shall be cast iron, variable pitch on applications 7.5 kW and smaller, and fixed pitch on 11 kW and larger. Model QSLSH shall be equipped with a two-groove drive minimum. INLET VANES — Inlet vanes, where specified, shall be of the nested design. Inlet vanes shall be designed for economical, stable, and efficient air volume control at partial load conditions. FINISH AND COATING — The entire fan assembly, excluding the shaft, shall be thoroughly degreased and de-burred before application of a rust-preventative primer. After the fan is completely assembled, a finish coat of paint shall be applied to the entire assembly. The fan shaft shall be coated with a petroleum-based rust protectant. Aluminum components shall be unpainted. FACTORY RUN TEST — All fans with motors and drives mounted by Twin City Fan & Blower shall be completely assembled and test run as a unit at the specified operating speed prior to shipment. Each impeller shall be statically and dynamically balanced in accordance with ANSI/AMCA 204-96 “Balance Quality and Vibration Levels for Fans” to Fan Application Category BV-3, Balance Quality Grade G6.3. Balance readings shall be taken by electronic type equipment in the axial, vertical, and horizontal directions on each of the bearings. Records shall be maintained and a written copy shall be available upon request. GUARANTEE — The manufacturer shall guarantee the workmanship and materials for its QSLSH Mixed Flow Fans for at least one (1) year from startup or eighteen (18) months from shipment, whichever occurs first.
WWW.TCF.COM
31
INDUSTRIAL & COMMERCIAL FANS Centrifugal Fans | Utility Sets | Plenum & Plug Fans | Inline Centrifugal Fans Mixed Flow Fans | Tubeaxial & Vaneaxial Fans | Propeller Wall Fans | Propeller Roof Ventilators Centrifugal Roof & Wall Exhausters | Ceiling Ventilators | Gravity Ventilators | Duct Blowers Radial Bladed Fans | Radial Tip Fans | High Efficiency Industrial Fans | Pressure Blowers Laboratory Exhaust Fans | Filtered Supply Fans | Mancoolers | Fiberglass Fans | Custom Fans
TWIN CITY FAN & BLOWER | WWW.TCF.COM 5959 Trenton Lane N | Minneapolis, MN 55442 | Phone: 763-551-7600 | Fax: 763-551-7601
©2015 Twin City Fan Companies, Ltd., Minneapolis, MN. All rights reserved. Catalog images cover the general appearance of Twin City Fan & Blower products at the time of publication and we reserve the right to make changes in design and construction at any time without notice.