Preview only show first 10 pages with watermark. For full document please download

Mfl67452409 Svc-parts Lmu540hv 20140911080003

   EMBED


Share

Transcript

Internal Use Only http://biz.lgservice.com Multi Air Conditioner SVC MANUAL(Exploded View) MODEL : A8UW54GFA0 [LMU540HV] CAUTION Before Servicing the unit, read the safety precautions in General SVC manual. Only for authorized service personnel. 1. Specification Btu/h Class Btu/h Btu/h kW kW kBbu/h.W Non Ducted Mixed Ducted V , Ø , Hz A A A A No. x AWG A8UW54GFA0 [LMU540HV] 54,000 14,000 ~ 52,500 ~ 63,200 15,467 ~ 58,000 ~ 64,000 1.0 ~ 5.10 ~ 5.86 1.49 ~ 5.34 ~ 6.19 10.3 / 3.2 18.4 / 8.7 17.1 / 8.7 15.8 / 8.7 208/230, 1, 60 4.6 ~ 23.7 ~ 27.2 6.9 ~ 24.8 ~ 28.7 3C x 4.0 No. x AWG 4C x 18 kBtu/h EA EA mm inch kg (lbs) Model x No. W x No. g (oz) m (ft) g/m (oz/ft) cc x No. m3/min(ft3/min) x No. W x No. dB(A) dB(A) dB(A) mm(inch) x No. mm(inch) x No. m (ft) m (ft) m (ft) m (ft) m (ft) m (ft) ℃ DB (℉ DB) ℃ WB (℉ WB) 73 8 2 Warm Gray 950 × 1380 × 330 37.4 x 54.3 x 13.0 97(213.8) Twin Rotary GPT442MAA x 1 BLDC 4,000 (at 60Hz) x 1 R410A 4,400 (155.2) 40 (131.2) 20 (0.22) Electronic Expansion Valve FVC68D 1,300 x 1 (2 x 32 x 14) x2 Propeller 60 x 2 BLDC 124.2 x 2 53 54 69 Ø 9.52 (3/8) Ø 19.05 (3/4) 145 (475.7) 55 (180.4) 90 (295.3) 15 (49.2) 30 (98.4) 15 (49.2) -10 (14.0) ~ 48 (118.4) -18 (-0.4) ~ 18 (64.4) Model Name Capacity Capacity Power Input Cooling Heating Cooling Heating Nominal Min.~Rated~Max. Min.~Rated~Max. Min.~Rated~Max. Min.~Rated~Max. EER / COP SEER / SCOP Power Supply Running Current Starting Current Wiring Connections Combination Cooling Heating Cooling Heating Power Supply Cable (included Earth) Power and Communication Cable (included Earth) Sum of Indoor Units Capacity Number of Indoor Units Number of BD Units Min.~Rated~Max. Min.~Rated~Max. Max. Max. Outdoor ~ BD unit Casing Color WxHxD WxHxD Dimensions Net Weight Compressor Refrigerant Refrigerant Oil Heat Exchanger Fan Fan Motor Sound Pressure Level Sound Power Level Piping Connections Piping Length Maximum Height Difference Operation Range (Outdoor Temperature) Type Model Motor type Motor Output Type Precharged Amount Chargeless-Pipe Length Additional Charging Volume Control Type Charged volume (Row x Column x Fins per inch) x No. Type Air Flow Rate Type Output Cooling Heating Cooling Liquid Gas Total Piping Main Piping Total Branch Piping Each Branch Piping Outdoor Unit ~ Indoor Unit Indoor Unit ~ Indoor Unit Cooling Heating Rated Rated Rated Outer Dia. Outer Dia. Max. Max. Max. Max. Max. Max. Min. ~ Max. Min. ~ Max. Note: 1. All data are based on the following conditions: - Cooling Temperature : Indoor 27°C(80.6°F) DB / 19°C(66.2°F) WB Outdoor 35°C(95°F) DB / 24°C(75.2°F) WB - Heating Temperature : Indoor 20°C(68°F) DB / 15°C(59°F) WB Outdoor 7°C(44.6°F) DB / 6°C(42.8°F) WB - Piping Length : Interconnected Pipe Length = 5m - Difference Limit of Elevation (Outdoor ~ Indoor Unit) is Zero. Copyright ©2012 LG Electronics. Inc. All right reserved. Only for training and service purposes 2. Wiring cable size must comply with the applicable local and national code. 3. Due to our policy of innovation some specifications may be changed without notification. 4. Sound Level Values are measured at Anechoic chamber. Therefore, these values can be increased(maximum 3dB(A)) owing to ambient conditions during opration. -2- LGE Internal Use Only 2. List of Functions & Accessory 2.1 List of Functions Category Reliability Convenience CAC Network Function Function Defrost / Deicing High Pressure Switch Low Pressure Switch Phase protection Restart Delay (3-minutes) Self Diagnosis soft start Test Function Auto operation(Artificial intelligence) Wiring Error Check Night Quiet Mode Peak Control Mode Lock Forced Operation Auto Restart Operation Central control(LGAP) Dry contact PDI(Power Distribution Indicator) PI485 A8UW54GFA0 [LMU540HV] O X X O O O O O O O O O O O O O O O O Note : O : Applied, X : Not applied * Option : Model name & price are different according to options, and assembled in factory with main unit. Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package. 2.2 List of Accessory Device Central Controller BNU (Building Network Unit) Installation Simple Controller Function controller Function Scheduler AC Ez AC Smart ll Option Kit (SD card type) ACP(Advanced Control Platform) AC Manager PI485 DO(Digital Output) Kit LONWORKS Gateway BACnet Gateway Y branch Header branch Air Guide BD Unit ODU Dry Contact Low Ambient Kit Copyright ©2012 LG Electronics. Inc. All right reserved. Only for training and service purposes -3- A8UW54GFA0 [LMU540HV] PQCSB101S0 PQCSB101S0 + PQCSC101S0 PQCSB101S0 + PQCSD130A0 PQCSZ250S0 PQCSW320A1E PQCSE341A0 / PQCSE342A0 PQCPA11A0E / PQCPB11A0E PQCSS520A0E PMNFP14A0/PMNFP14A1 PQNFP00T0 PQNFB16A1 PQNFB17B0 PMBL5620 PMBL1203F0 X PMBD3620, PMBD3630, PMBD3640 O O (Logical operation) LGE Internal Use Only 3. Piping Diagrams Outdoor Unit Inlet Air Temperature Thermistor Condenser Out Temperature Thermistor Condenser Mid Temperature Thermistor Ø9.52 Flare Connection Strainer M Strainer Electronic Expansion Valve Pressure Sensor Ø19.05 Flare Connection Fusible Plug Hotgas Valve Suction Temperature Thermistor 4 way Valve Discharge Temperature Thermistor Accumulator Inverter Compressor : Cooling : Heating PCB Connector Description CN-TH1 Air / Cond Out CN-TH2 Suction / Discharge CN-TH3 Cond Mid CN-P/SENSOR(H) Pressure Sensor CN-EEV-MAIN Electronic Expansion Valve CN-HOTGAS Hotgas Valve Copyright ©2012 LG Electronics. Inc. All right reserved. Only for training and service purposes -4- LGE Internal Use Only 4. Wiring Diagrams MAIN PCB INVERTER PCB CN-485/DRY CN(L) CN_EEV_MAIN CN(N) CN-HOTGAS CN-COM CN-MOTOR1 CN_JIG_PC CN_CENTRAL CN_TH1 CN_4WAY CN-MAIN CN-MOTOR2 CN_TH2 CN_TH3 CN-P/SENSOR (H) CN_WRITER CN_FLASH WCN_P(N) CN_POWER WCN_P(L) CN_COMM CN_POWER Copyright ©2012 LG Electronics. Inc. All right reserved. Only for training and service purposes -5- LGE Internal Use Only 5. Exploded View 549610 554031A 237204 552111 435300 552115 559010 546810A 352111 546810B 559010 435512 554031B 554160 649950 55211G 263230C Air / Cond-Out 552200 268711D Cond-Mid 263230A 437212 548490 661400 W6200 237205 552117 268711C W52240 W0FZZ W6640B 237202 263230B 349480 Suction / Discharge pipe 552116 W6640A 561410D 552202 561410A 435301 447910 165010 Pressure sensor 148000 135500 552560 552203A W6631 552203B 554160 435513 137213 550140A 349480 430410 152503 437211 435301 550140B Location No. PCB Connector Description Housing Color 263230C CN-TH1 Air / Cond Out White 263230B CN-TH2 Suction / Discharge Red 263230A CN-TH3 Cond Mid Blue 165010A CN-P/SENSOR(H) Pressure Sensor Red Copyright ©2012 LG Electronics. Inc. All right reserved. Only for training and service purposes -6- LGE Internal Use Only P/NO : MFL67452409 JULY, 2012