w w w. m g e u p s . c o m Standard Features ◗ When used with standard system, EX RT Transformer Module provides isolated and Step-down 120/208/ 240 Vac outputs. ◗ Multiple Output receptacles: 120/208/240 Vac. E X RT Transformer Installation and User Manual 86-86000-03 AO EX RT Transformer STEP 1 EX RT Transformer Unpacking and Parts Check EX RT Transformer Box Contents Tower Stand Extenders EX RT Transformer Installation and User Manual Stabilizer Bracket (4 screws included) STEP 2 EX RT Transformer Tower Configuration Tower Configuration of Standard System with Transformer Module 5 Transformer Power Module EX EXB Battery Modules T 11 R T 11 R Power Module Transformer Battery Module (up to 6) 3 4 3 4 4 4 2 1 2 1 2 EX RT Transformer Installation 86-86000-03 AO Installation and User Manual STEP 3 Rack Configuration (Requires optional Rail Kits 86001, 86002) See System Installation and User Manual for details. A. Stack-up sequence in Rack configuration Prepare the power module front panel logo and LCD display for rack orientation. Apply to all modules. (Power Module shown.) 1. EX RT Transformer (Top) former EX RT Trans 1 RT EX 1 EX m www.mgeups.co 11 OFF RT 2. POWER MODULE (upper, EX 5/7/11 RT) ON OFF www.mgeups.com m www.mgeups.co ON EX 11 RT ON OFF m www.mgeups.co FINISHED PANEL (rack orientation) EX 11 OFF RT 1 www.mgeups.co 4. BATTERY MODULE (bottom, EXB 5/7/11 RT) ON www.mgeups.com 1 3. BATTERY MODULE (lower, EXB 5/7/11 RT) former EX RT Trans m former EX RT Trans 2 2 1 RT EX 1 m www.mgeups.co m www.mgeups.co 3 ON OFF 3 (Shown with power module and 2 battery modules) B. Rack Installation 1 1. Attach both rails to rear and front of rack chassis with supplied screws. 1 1 3. Install Front Mounting Brackets to each side of the transformer Module. 1 3 2 2. Attach rails together with provided wing nuts. 4 3 4 4. Use caution when sliding unit into rack mount, secure unit to rack with supplied screws. (For this step, it is possible to adjust the position of both front mounting brackets.) 86-86000-03 AO EX RT Transformer Installation 3 EX RT Transformer STEP 4 Systems Connections EX RT Transformer, Power Module and Battery Module Connections A. System Connections with Transformer Battery Module EXB 5/7/11RT Battery Detection Cable 3 Power Module EX 5/7/11 RT Battery Power Cable Transformer Module EX RT 2 Transformer Main Output Circuit Breaker Power Module Connector 4 Battery Module Circuit Breaker 1 Follow connection diagram for appropriate input/output voltages. AC Normal INPUT Transformer OUTPUT TO LOAD 4 (*) Power Module Circuit Breaker 1. Check that the battery circuit breaker is OFF (“0”) position. 2. Connect the battery power cable to the connectors of the power and battery modules, 3. Connect the battery detection cable between connectors of the power and battery modules. 4. Turn on battery module circuit breaker, power module circuit breaker and XFMR Main Output Circuit Breaker. Connection Diagram (bottom of Transformer I/O Box) L3 L2 208Vac 240Vac L1 Lb Ld N 120Vac 120Vac 208Vac 240Vac AC Input Lc AC Output La Transformer Module Terminal block capacity: maximum 4 AWG solid or stranded wire on transformer module. (*) Input/Output Box Terminal Block capacity: maximum 4 AWG, 6 AWG solid or stranded wire on EX 11RT, and EX 5/7 RT respectively. See System Installation and User Manual for initial start-up procedures. 4 EX RT Transformer Installation 86-86000-03 AO www.mgeups.com Contact MGE United States MGE UPS SYSTEMS 1660 Scenic Ave. Costa Mesa, CA 92626 Tel: (714) 557-1636 (800) 523-0142 Fax: (714) 557-9788 email: [email protected] www: mgeups.com Canada MGE UPS SYSTEMS #9, 2789 Thamesgate Drive Mississauga, ON L4T 4E8 Tel: (905) 672-0990 (877) 672-0990 Fax: (905) 672-7667 email: [email protected] www: mgeups.com Latin America and Other International MGE UPS SYSTEMS 1660 Scenic Ave. Costa Mesa, CA 92626 Tel: (714) 513-7831 (800) 523-0142 ext. 7831 Fax: (714) 434-0199 email: [email protected] www: mgeups.com 1 6 6 0 S c e n i c Ave n u e, C o s t a M e s a , C a l i fo r n i a 9 2 6 2 6 • ( 7 1 4 ) 5 5 7 - 1 6 3 6