Mi 3100_naslovna.cdr

   EMBED


Share

Transcript

EurotestEASI MI 3100 Lightweight and Compact Electrical Installation Tester MATRIX dot LCD Effective bright information. Back-lit display. Jogger interface TOUCH electrode with MEM User friendly. MEM HELP Evaluation of the results. PASS or FAIL. Help menu with connection diagrams. Innovative Instruments Designed with You in Mind ring g u s a Me shootin ble Trou e s t i n g T CE conformity: EN 61010-1; EN 61326 Functional conformity: EN/IEC 60364; EN 61557; BS 7671; CEI 64.8; HD 384; VDE 0413 Continuity test • Clear, fast and easy access - user friendly interface. • Checking, testing and evaluating safety conditions with PASS/ FAIL evaluation ON-LINE. • Maintenance and troubleshooting. • Building and constructing. • Small, compact, robust and highly protected. 200mA Insulation test Complete RCD RCD - TRIP LOCK Line/Fault Loop HV AUTO Ipsc evaluator Patent pending R World’s first. Earth resistance Rs Loop Test and voltage drop calculation www.metrel.si impedance and Ipsc Main Features Help Help menus with short guide and graphical circuits are enclosed to all the instrument's functions. Complete needed information is just one press on HELP button away. Continuity test Continuity testing - Carried out at standardized both polarities 200 mA test and allows automatic nulling of test leads. Electronically protected against in-correct connection. Complete RCD analysis Insulation test Insulation test - 100 V, 250 V, 500 V and 1000 V DC. Reads up to 1000 MOhm to provide early indication of faults. Electronically protected against in-correct connection. • Continuity test Complete RCD analysis - RCD’s trip out time and trip out current as single or automatic 6-step test: 0°x1/2, 180°x1/2, 0°x1, 180°x1, 0°x 5, 180°x 5 for type A and AC. Built in PASS bands for fast evaluation of results. • Insulation test 100 V, 250 V, 500 V and 1000 V PCC3 PCC1 L1 L2 L3 N PE switched off mains voltage • RCD test /Earth resistance Rs Loop Test and voltage drop calculation L1 L2 L3 N PE closed switches PE/L3 N prolongation lead MPEC disconnected loads Ro PCC2 L/L 1 N/L2 RE PE L 115/230/440V 55V/63V TN/TT/IT low-voltage system support. Reduced low-voltage system support. Multi Voltage Monitor - ON LINE Three voltmeters on a display for permanent monitoring present voltages between lines, neutral and PE conductors. For Single and Three phase systems. Multi Voltage System Support - The instrument is designed to fully support TT/TN and IT systems for standard low voltage and reduced low voltage systems. Cross-matrix testing - Simultaneous testing of all possible values of Fault Loops, Isc and Rs loop test on both polarities enabled on IT system as well as on 55 V / 65 V reduced low-voltage systems. Phase Rotation - Testing of phase sequences with voltage monitor between phases. PE Test Probe - Tests for the presence of voltage on PE conductors (faults, L and PE reversed, ...). Long life charger pack. Auto Power OFF. Multi-language support. Rechargeable NiMH batteries1.2 V, up to 2500 mAh or standard 1.5 V alkaline batteries can be used. Automatic switch off the tester helps saving the batteries. On screen information with help menus as well as front panel labels are available in many languages. CAT III 600V Line/Fault Loop impedance and Isc Automatically calculating Ipsc with custom adjusted safety factor. A built in table of Fuse characteristics allows the instrument to indicate a Pass or Fail! Another Worlds first in instrument testing! RCD - TRIP LOCK FUSE base with characteristics. BUILT-IN. Fuse table with characteristics built inside instrument. RCD - TRIP LOCK Rs Loop Test - Allows for fast and accurate non trip loop testing in the presence of any RCD. Also allows a readout of touch voltage levels. • Line/Loop test N Ro RE PE Evaluation of results with safety factor of Isc. Custom selectable. L/L1 L/ L1 L1 L2 L3 N PE N/L2 L1 L2 L3 N PE PE/L3 • Phase rotation / Voltage L option A 1110 N/L2 result 1.2.3 Technical specification Order Information Insulation resistance (EN 61557-2) Meas. ranges (MW): Nominal voltages: Measuring current: Short-circuit current: 0.000 ¸ 199.9; Acc. ±(5 % of r. + 3 dig.), UN=100 Vb, 250 Vb 0.000 ¸ 199.9; Acc. ±(2 % of r. + 3 dig.), UN= 500 Vb, 1000 Vb 200 ¸ 999; Acc. ±(10 % of r.), UN= 500 Vb, 1000 Vb 100 V, 250 V, 500 V, 1 kV (b) min.1 mAb at RN=UN ´1 kW/V <3 mAb Standard set Ordering No. MI 3100 Continuity R Low W (EN 61557-4) Meas. ranges (W): Test current: Open-circuit voltage: 0.00 ¸ 19.99; Acc. ±(3% of r. + 3 dig.) 20.0 ¸ 99.9, 100 ¸ 1999; Acc. ±(5% of r.) min. ±200 mAb at 2 W 6.5 Vb ¸ 9.0 Vb Continuity 7mA Meas. ranges (W): Test current: Open-circuit voltage: 0.0 W ¸ 99.9, 100 ¸ 1999; Acc. ±(5% of r. + 3 dig.) max. 8.5 mA b 6.5 Vb ¸ 9.0 Vb Line resistance RL-N(L) (EN 61557-3) Meas. ranges (W): IPSC: Nominal voltage: 0.00 ¸ 19.99, 20 ¸ 99.9, 100 ¸ 1999; Acc. ±(5% of r. + 5 dig.) 0.00 A ¸ 24.4 kA 100 V ¸ 440 V / 45 Hz ¸ 65 Hz Fault loop resistance RL-PE (EN 61557-3) Meas. ranges (W): IPFC: Nominal voltage: 0.00 ¸ 19.99, 20 ¸ 99.9, 100 ¸ 1999; Acc. ±(5% of r. + 5 dig.) 0.00 A: ¸ 24.4 kA 100 V ¸ 264 V / 45 Hz ¸ 65 Hz Voltage, frequency Meas. range (V): Meas. range (f): 0 ¸ 440 V; Acc. ±(2 % of r. + 2 dig.) On-line voltage monitor in all measurement functions 45 Hz ¸ 65 Hz; Acc. ±(0.1 % of r. + 1dig.) Phase rotation (EN 61557-7) Results displayed: Nominal voltage: 1.2.3 or 2.1.3 100 V ¸ 440 V / 45 Hz ¸ 65 Hz - Instrument - Tip commander with two function key - Schuko-plug test cable - Test cable Universal connection 3 x 1.5 m - Test tip, blue - Test tip, black - Test tip, green - Alligator clip, 3 pcs - Soft carrying neck belt - Soft carrying bag - NiMh battery pack - Battery Charger - Instruction manual - short - Declaration of conformity - Product verification data - CD with … s kom ali s cim? Optional Accessories RCD (EN 61557-6) Meas. range (IDN): Nominal voltage: 10 mA, 30 mA, 100 mA, 300 mA, 500 mA, 1000 mA 100 V ¸ 264 V / 45 Hz ¸ 65 Hz Contact voltage UC Meas. ranges (V:): 0.0 ¸ 9.9, Acc. (-0 % / +10 % of r. + 2 dig.) 10 ¸ 99.9, Acc. (-0 % / +10 % of r.) RS: 0.00 W ¸ 10.00 kW, (RS=UC / IDN) Fault loop resistance R L: 0.00 W ¸ 1999 kW Tripping time Non-delayed (time-delayed) RCDs ´1: 0 ms ¸ 300 ms (500 ms) ´2: 0 ms ¸ 150 ms (200 ms) ´5: 0 ms ¸ 40 ms (150 ms), UC: 0.0 V ¸ 100.0 V A 1111 A 1110 Tripping current Multiplier: A 1027 ID: 0.2 ´ IDN ¸ 1.1 ´ IDN AC (¸1.5 ´ IDN A) tD: 0 ms ¸ 300 ms, UC: 0.0 V:: ¸ 100.0 V:: ´0.5, ´1, ´2, ´5 General Power supply voltage Charger supply unit Overvoltage category Plug commander - overvoltage category (optional) Protection classification Pollution degree Protection degree Display Dimensions (w x h x d) Weight (with batteries) Working temperature range 9 VDC (6 x 1.5 V battery cells or accus, size AA) 12 V ÷ 15 V CAT III / 600 V CAT III / 300 V double insulation 2 IP 42 128 x 64 dots matrix display with backlight (230 x 103 x 115) mm 1,32 kg 0 OC ¸ 40 OC Measurement and Regulation Equipment Manufacturers, Ljubljanska 77, SI-1354 Horjul Tel.: +386 1 75 58 200; Fax: +386 1 75 49 226 http://www.metrel.si; E-mail: [email protected] A 1001 A 1111 A 1110 A 1001 A 1154 A 1153 A 1027 Distributor: A 1153 Three phse adapter Three phase cable Plug commander Test lead, blue, 4 m Test lead, blue, 20 m Test lead, blue, 50 m A 1154