Transcript
PVAZ172NPbF Microelectronic Power IC ®
HEXFET Power MOSFET Photovoltaic Relay Single-Pole, Normally-Open, 0-60V AC, 1.0A
General Description The PVAZ172N Photovoltaic Relay is a single-pole, normally open solid state relay that can replace electromechanical relays used for general purpose switching of DC and AC loads. It utilizes International Rectifier’s HEXFET power MOSFETs as the output switches, driven by an integrated circuit photovoltaic generator of novel construction. The output switch is controlled by radiation from a GaAlAs light emitting diode (LED) which is optically isolated from the photovoltaic generator. These units overcome the limitations of both electromechanical and reed relays by offering the solid-state advantages of high sensitivity, miniaturization, no contact bounce, long operational life, insensitivity to external magnetic fields, shock and vibration, and high reliability inherent with solid state technology. They are ideally suited for switching high currents or low level signals without distortion or injection of electrical noise. These relays are packaged in 8-pin, molded DIP packages and available with either thru-hole or surface-mount (“gull-wing”) leads, in plastic shipping tubes.
Features
500mΩ On-Resistance Bounce-Free Operation 1.0 Amp capacity 4,000 VRMS I/O Isolation Solid-State Reliability UL recognized ESD Tolerance: 4000V Human Body Model 500V Machine Model
Applications
Portable Electronics
Programmable Logic Controllers
Part Identification
Computers and Peripheral Devices
PVAZ172NPbF
Audio Equipment
Power Supplies and Power Distribution
Instrumentation
PVAZ172NSPbF surface-mount (gull-wing) PVAZ172NS-TPbF surface-mount tape and reel
thru-hole
(HEXFET is the registered trademark for International Rectifier Power MOSFETs) 1
www.irf.com © 2015 International Rectifier
Submit Datasheet Feedback
April 29, 2015
PVAZ172NPbF
Electrical Specifications (-40°C ≤ TA ≤ =+85°C unless otherwise specified) INPUT CHARACTERISTICS
Limits
Units
Min. Control Current (see figures 1 and 2)
10
mA
Max. Control Current for Off-State Resistance @ TA=+25°C
0.4
mA
5.0 to 25
mA
6.0
V
Control Current Range (Caution: Current limit input LED, see figure 6) Maximum Reverse Voltage
OUTPUT CHARACTERISTICS Operating Voltage Range
0 to 60
V(AC peak)
Maximum Load Current 40° C (see figures 1 and 2)
1.0
A (DC)
Maximum Pulsed Load Current @TA=+25°C (100 ms @ 10% duty cycle)
2.4
A (AC peak)
Maximum Turn-On Time @TA=+25°C (see figure 7)
2.0
ms
0.5
ms
500
mΩ
For 500mA, 50VDC Load, 10mA Control Maximum Turn-Off Time @TA=+25°C (see figure 7) For 500mA, 50VDC Load, 10mA Control Maximum On State Resistance @TA=+25°C(pulsed) (See figure 4) 1.0A Load, 10mA Control Minimum Off State Resistance @TA=+25°C @ 48 VDC (see figure 5)
108
Ohms
Minimum Off-State dv/dt
1000
V/µs
Output Capacitance (see figure 9)
150
pF @ 50 VDC
Limits
Units
4000
V(RMS)
GENERAL CHARACTERISTICS Dielectric Strength, Input-Output 1012 @T
Insulation Resistance, Input-Output , 90 VDC
A=+25°C
Capacitance, Input-Output Lead Temperature (1.6mm below seating plane) for 10 seconds Ambient Temperature Range:
- 50% RH
1.0
Ω pF
+260
°C
Operating
-40 to +85
°C
Storage
-40 to +100
°C
International Rectifier does not recommend the use of this product in aerospace, avionics, military or life support applications. Users of this International Rectifier product in such applications assume all risks of such use and indemnify International Rectifier against all damages resulting from such use.
2
www.irf.com © 2015 International Rectifier
Submit Datasheet Feedback
April 29, 2015
PVAZ172NPbF
Wiring Diagrams:
Anode
2
+
8
2
8
3
5
Drain
+ Cathode
3
5
Drain
Schematic
Electromechanical Analogy
1.25
1.2 ILED = 10mA
1.0
1.00
+25 deg. C
0.8 ILED = 5mA (Typical)
0.75
0.6 0.50
0.4 +60 deg. C 0.25
0.2
+85 deg. C
+40 deg. C
0
0
20
40
60
0
100
80
1
2
3
4
5
LED Control Current (mA)
Ambient Temperature (deg. C)
Figure 1. Current Derating Curves
Figure 2. Typical Control Current Requirements
500
1.2
+40 deg. C +60 deg. C
1.0
400 +85 deg. C
0.8
300
+25 deg. C
0.6
200
0.4
ILED = 10mA 100
0.2
0 0
0.1
0.2
0.3
0.4
0.5
Vds (V)
Figure 3. Typical On-Characteristics
3
www.irf.com © 2015 International Rectifier
0 -40
-20
0
20
40
60
80
100
Ambient Temperature (deg. C)
Figure 4. Typical On-Resistance
Submit Datasheet Feedback
April 29, 2015
PVAZ172NPbF
100
CAUTION: provide current limiting so that 25 mA maximum steadystate control current rating is not exceeded
30
deg. C limit
TYPICAL
4
0.3
0.1 -35
8
Max . device and
1.0
12
Min. device and +85
3.0
-40 deg. C limit
16 10
Input Current (mA)
Id-off/Id-off 25 deg. C
20
-15
5
25
45
65
85
0
105
0
Ambient Temperature (deg. C)
0.5
1.0
1.5
2.0
LED Forward Voltage Drop (Volts DC)
Figure 6. Input Characteristics (Current Controlled)
Figure 5. Typical Normalized Off-State Leakage
20
10 I LED
ton
90%
toff
5
tdly I D 10% tdly
3
20
50
100
200
500
ton
t off
1000 2000
Delay Time (microseconds)
Figure 7. Typical Delay Times
Figure 8. Delay Time Definitions 600
450
300
150
0 0
10
20
30
40
50
Vds, Drain to Source Voltage (V)
Figure 9. Typical Output Capacitance 4
www.irf.com © 2015 International Rectifier
Submit Datasheet Feedback
April 29, 2015
PVAZ172NPbF Case Outline
01-2013
00 (MS-001AB)
01-2019
00
Note: For the most current drawing please refer to IR website at: http://www.irf.com/package/
5
www.irf.com © 2015 International Rectifier
Submit Datasheet Feedback
April 29, 2015
PVAZ172NPbF
Qualification information† Qualification level Moisture Sensitivity Level RoHS compliant
Industrial †† (per JEDEC JESD47I guidelines) PVAZ172NPbF N/A PVAZ172NSPbF MSL4 PVAZ172NS-TPbF (per JEDEC J-STD-020E & JEDEC J-STD-033C ††) Yes
† Qualification standards can be found at International Rectifier’s web site: http://www.irf.com/product-info/reliability †† Applicable version of JEDEC standard at the time of product release
Revision History Date 4/29/2015
Comments • Added Qualification Information Table on page 6 • Updated data sheet with new IR corporate template
IR WORLD HEADQUARTERS: 101 N. Sepulveda Blvd., El Segundo, California 90245, USA Data and specifications subject to change without notice To contact International Rectifier, please visit http://www.irf.com/whoto-call/ 6
www.irf.com © 2015 International Rectifier
Submit Datasheet Feedback
April 29, 2015