Transcript
GPS350 Installation & Configuration Quick Reference Guide
MicroMax GPS350 Installation and Configuration Derating Table Ambient Temperature Celsius
Fahrenheit
Interruption Cycle 0.8 s ON - 0.2 s OFF
4 s ON - 1 s OFF
25 ⁰C
77 ⁰F
60 A
80 A
35 ⁰C
95 ⁰F
60 A
80 A
45 ⁰C
113 ⁰F
58 A
78 A
55 ⁰C
131 ⁰F
49 A
66 A
65 ⁰C
149 ⁰F
38 A
51 A
Required Tools Voltmeter
Optional Tools Windows® Laptop PC Bullhorn® Tools configuration software USB to mini-USB cable
CAUTION: Metal relay casing on the MicroMax GPS350 will get hot. Allow 5 - 10 minutes after interruption stops before handling the unit.
CAUTION: Do not connect the MicroMax GPS350 to primary power.
WARNING: Before beginning any wiring to the MicroMax GPS350, ensure that power has been turned off at the rectifier.
Installing the Equipment The following procedures are general steps for a typical installation. For specific instructions, see the MicroMax GPS300 & GPS350 User Guide (part no. 122204-000) available from your website account under the Help menu.
(Continued) © 2016-2017 American Innovations,
1 of 4
Part No. 122207-000, Rev. 1
MicroMax GPS350 Installation and Configuration Quick Reference Guide
1
Locate Power Source for MicroMax GPS350 1 Determine how to power the MicroMax GPS350 using one of the following sources:
Quick Reference Guide
a With power turned on to the rectifier, use a voltmeter to locate a power source across any two available AC taps. The MicroMax GPS350 requires 8 - 42 V AC. b A 120 V AC convenience outlet with the 12 V DC wall adapter.
POWER DEVICE WITH: FINE/COARSE TAPS 8 V - 42 V AC OR 12 V DC WALL ADAPTER
c A DC source, such as a 10 - 60 V DC battery. 2 Turn off rectifier power.
OR BATTERY 10 V - 60 V DC
2
Connect Relay to Rectifier 1 To interrupt the AC power:
2 To interrupt the DC power:
a Remove the tap change bar from the taps.
NOTE: These connections are not polarity sensitive. a Disconnect the DC output cable. Then connect one of the MicroMax GPS350 relay cables to output. GPS350 Relay Connected to Rectifier Positive Output
Tap Change Bar
b Slide shrink wrap tube (provided) onto the second MicroMax GPS350 relay cable.
b Connect the two MicroMax GPS350 relay wires to the taps. NOTE: Connect relay wires to the same taps that were connected by the change bar.
c Connect the MicroMax GPS350 relay cable to the DC output cable using available hardware.
GPS350 Relay Cable & DC Output Cable
d Wrap assembly with shrink wrap to prevent equipment shorting. GPS350 Relay Cable & DC Output Cable Wrapped
GPS350 Relay Connected to Rectifier AC
(Continued)
CAUTION: Do not connect the MicroMax GPS350 to primary power.
January 2017
2 of 4
Part No. 122207-000, Rev. 2
MicroMax GPS350 Installation and Configuration Quick Reference Guide
3
Connect Power Cable
Power
1 Connect Power Cable to MicroMax GPS350 Power connection.
Power Cable
GPS350 Power Connection
2 OPTIONAL: If external relay is used, connect relay control or coil to Power Cable OUTPUT. Be sure to observe proper polarity, especially if a flyback diode is present on a mercury relay coil.
Power Cable OUTPUT
3 Connect red/white twisted wire cable to INPUT connection on Power Cable. Then clip alligator clips to rectifier AC taps. Voltage range is 8 - 42 V AC. Alligator Clips on Rectifier Taps
4
Twisted Wire Cable Connected to Power Cable
Connect GPS Antenna Cable to MicroMax GPS350 1 Connect GPS antenna cable to MicroMax GPS350 GPS Antenna connection.
GPS Antenna
2 Place GPS antenna outside of rectifier in an area with a clear view of the sky. GPS Antenna
GPS350 GPS Antenna Connection
(Continued)
WARNING: Ensure that the antenna connection does not come into contact with any conductive surface of the rectifier. © 2016-2017 American Innovations,
3 of 4
Part No. 122207-000, Rev. 2
5
MicroMax GPS350 Installation and Configuration Quick Reference Guide
Program MicroMax GPS350 The following procedures are general steps for programming the GPS350 using the unit keypad. For instructions on programming the unit with Bullhorn Tools, refer to the online help available from the Bullhorn Tools Help menu or to the MicroMax GPS300 & GPS350 User Guide. 1 Power on the rectifier. 2 Press 3 Use
to view GPS information. and
12:01:03 02/25 1:Interrupt
to change display contrast.
4 OPTIONAL: From the main menu, press run Test Mode. Press
to
to return to main menu.
2:GPS
3:Interference
4:Options
:Test
MicroMax GPS350 Main Menu
5 Press to set up an Interruption program OR to set up an Interference program. 6 For Interruption, enter a number between 1 and 9 for the program number. a Press to select interruption schedule - Daily, Continuous, or Start/Stop. b Use and to move through fields; use keypad to change settings. c Press
# 5 On 12.0 Off 03.0 Start 06:00 01/01/14 Stop
Change:
a Press to access a list of Options and then to view or edit Switch and Int. Cycle options. b To change settings, move the cursor to the option and press .
/
Set:
Interruption Program
to begin program.
7 For Interruption Output Parameters:
18:00 12/31/99
Switch: Norm Closed Int. Cycle: ON/OFF Move:
Change:
Done:
Cancel:PREV Out Parameters
8 For Interference: a Use
and
to move through fields. Use
keypad to change settings.
#10 On 13.0 Off 05.0
b Press
to select type of interruption.
Delay 002.0
c Press
to select interruption schedule - Daily,
Unit #07/10 Next:
Cycle Time 0088s
Continuous, or Start/Stop. d Use
and
Interference Program
to move through fields. Use
keypad to change settings. e Press
to begin program.
9 Close and lock the clear cover on the MicroMax GPS350. Place interrupter inside the rectifier.
January 2017
4 of 4
Part No. 122207-000, Rev. 2