Twin zooming objective optical system
Type
8x ~ 35x (4x ~ 70x by replacing eyepiece and/or aux iliary obje c tive le ns )
7x ~ 30x (3.5x ∼60x by replacing eyepiece and/or aux iliary obje c tive le ns )
Eyepiece
SM 10xB eyepieces (F.N. 21), SM 15xB eyepieces (F.N.14), SM 20xB eyepieces (F.N. 12)
Zoom range Auxiliary objective lens
0 . 8 x ~ 3 . 5 x (Zoom ratio: 4 . 4 : 1 ) AL0.5x, 0.7x (optional)
Working distance Eyepiece inclination
0 . 7 x ~ 3 x (Zoom ratio: 4 . 3 : 1 )
Optical system
45 º 60 º True erect image, 12 º inner bevel, independent adjustment of right and left eyepieces, and 54 to 75mm interpupillary adjustment
Weight (Zooming body)
Approx. 1.0kg
Dimensions Combination with the LED Stand
Combination with the LED Stand
160
160 E.P
325
120 ∼225
120 ∼225
350.5
350.5
E.P
0°∼5 5°
0°∼5
5°
200
325
200
325
366
Speci cations and equipment are subject to change without any notice or obligation on the part of the manufacturer. December 0072 ©2007 NIKON CORPORATION
Biological Microscope ECLIPSE E100
Biological Microscope
Specifications Optical system
CFI optical system
Magnification 40 –1500x Illumination 6V-20W halogen lamp, FL (field lens) unit, lamp changeable by removing the field lens unit Coarse and fine focusing Coaxial coarse/fine focusing with cross roller guide incorporated, 22mm coarse/fine focusing range, Coarse motion: 37.7mm/rotation, Fine motion: 0.2mm/rotation with 2µm scale increments, Coarse motion torque adjustable Eyepiece tube Eyepiece lens (with rubber eye guard) Condenser
E2-TB binocular tube (inclination: °, 360° 30 rotatable Siedentopf-type, interpupillary distance: –75mm) 47 E2-TF trinocular tube F (2-way, inclination:°,30 360° rotatable Siedentopf-type, interpupillary distance: –75mm) 47 E1-CFI 10x (F.O.V.: 18mm), CFI E 15x (F.O.V.: 12mm) Abbe condenser, NA 1.25 (aperture diaphragm with position guide marking for respective objectives), 33mm-diameter filters attachable (including standard blue filter)
Nosepiece
Quadruple click-stop, revolving mechanism with multiple ball bearings, elastic nosepiece grip-ring
Dedicated objectives
CFI BE Plan Achromat 4x (NA 0.1/W.D. 25mm), 10x (NA 0.25/W.D. 6.7mm), 20x (NA 0.4/W.D. 3.7mm), 40x5/W.D. (NA 0.60.6mm), 60x (NA 0.8/W.D. 0.24mm), 100x (NA 1.25/W.D. 0.14mm), DL 10x (NA 0.25/W.D. 6.7), DL 40x (NA 0.65/W.D. 0.6), DL 100x (NA 1.25/W.D. 0.14)
Stage
Double-plate rectangular mechanical stage, stage size: 155 (W) x 134 (D)mm, removal slide holder, travel area: 76(D)mm, (W) x 40 vernier provided Adjustable vertical condenser movement range: 10mm
Substage Optional accessories
Phase contrast attachment (dedicated Abbe condenser, sliders, objectives (10x, 40x, 100x), GIF filter, e centering phas telescope), object marker, darkfield ring unit, mirror unit, cord hanger, storage case 50W
Power consumption Weight
Approx. 7.3kg Unit: mm
Dimensional Diagram 204.8
378
63
190
281
374
E.P.
145.2 237
111 150 235
Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. December 2009 ©2006-09 NIKON CORPORATION WARNING
TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT.
* Monitor images are simulated. Company names and product names appearing in this brochure are their registered trademarks or trademarks.
Biological Microscope
Eclipse E200-F (model with field diaphragm)
Eclipse E200
Dimensional Diagram 206.4
381.7 (When PD is 64mm.)
411.4 (Eyepoint height when PD is 64mm.)
315
407.4 (Minimum microscope height)
191.3
414.6 (When PD is 64mm.)
101.5
226.8 105 188.5
247.7
Unit: mm
Optical system
Eyepiece tube
Eyepiece Photo lens Nosepiece focusing
Stage
Objectives
WARNING
Parfocal distance: 60mm 40–1500X for observation 8–500X for 35mm photomicrography E2-TB Binocular tube, E2-TF Trinocular tube Siedentopf type (Inclination: 30°, Interpupillary distance: 47-75 mm, 360° rotatable) C-TE Ergonomic Binocular Tube (inclination: 1030º, extension: 40mm) CFI E 10X (F.O.V.: 20mm), CFI E 15X (F.O.V.: 12mm) PLI projection lens: 2X, 2.5X, 4X, 5X Quadruple nosepiece, reversed type Fine: 0.2mm per rotation, Coarse: 37.7mm per rotation, Minimum reading: 2 microns on left-side adjustable, Refocusing system incorporated in stage, Stage handle and focusing knob are at equal distance from the operator Rectangular 216 x 150 mm surface stage mounted on the main body. Cross travel 78 x 54 mm using low-positioned X/Y coaxial control knob CFI E Plan Achromat 4X N.A. 0.10 (W.D. 30mm) CFI E Plan Achromat 10X N.A. 0.25 (W.D. 0.7mm)
Condenser
CFI E Plan Achromat 40X N.A. 0.65 (W.D. 0.65mm) CFI E Plan Achromat 100X Oil N.A. 1.25 (W.D. 0.23mm) As an option, CFI Achromat DL and other higher-grade CFI60 objectives can be used E2 Abbe condenser N.A. 1.25; leaf-type aperture diaphragm with position guide markings for respective CFI E Plan objectives Optional condensers: E2 Phase condenser N.A. 1.25; leaf-type aperture diaphragm with position guide markings for respective CFI Achromat DL objectives C-C Achromat Condenser Achromat Swing-out Condenser
Illumination system Intermediate attachment *
C-C Phase Contrast Condenser 6V-20W halogen bulb, 6V-30W halogen bulb Compliant with multi-voltage (100V-240V) head (face-to-face and side-by-side types), Drawing tube, Eye level riser * Maximum intermediate space 50mm
TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT.
on the part of the manufacturer. March 2010
n ©2000-10 NIKON CORPORATION
0 8-541-45 84
Stereoscopic Microscope SMZ745/745T
Nikon's stereoscopic microscope with 7.5x zoom and 115 mm working distance ! a superior model in this category 7.5x zoom: extremely high zoom range The SMZ745/745T boasts a 7.5x zoom that incorporates the Greenough optical system. The zoom range of 0.67x to 5x provides a broad observation range.
Trinocular optical head is ideal for monitoring and digital imaging (SMZ745T only) The SMZ745T incorporates an optical path switching lever that enables easy switchover between eyepiece and camera. Nikon Digital Sight series camera can be attached.
Superior 115 mm working distance As well as high zoom ratio and magnification, the SMZ745/745T offers a long 115 mm working distance.
Optical path switching lever
Working distance: 115 mm
With Digital Sight series camera for microscopes
Three “A” design The airtight, anti-mold, anti-electrostatic design makes the SMZ745 suitable for use in a range of working environments. * The SMZ745T has an anti-mold, antielectrostatic design.
Specifications
SMZ745
SMZ745T
Optical system
Greenough optical system
Total magnification
3.35-300x (depending on eyepiece and auxiliary objective used)
Vertical tube
Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD
Eyepiece tube
Fixed type
Eyepiece inclination
45 °
Interpupillary distance adjustment
52-75 mm
Eyepieces (with diopter adjustment)
C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7)
Zoom range
0.67-5x
Zoom ratio
7.5:1
Auxiliary objectives
G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm)
Working distance
115 mm (standard)
Weight
1.55 kg (SMZ745), 1.8 kg (SMZ745T)
F.N.: Field Number
System diagrams
Rubber Eyeguard SM Opal & Black Acrylic Plate
Horn-shaped Eyeguard C-FC Crosshairs
C-FM Micrometer
SMZ Glass Plate
ESD Plate
C-W 10xB C-W 15x C-W 20x C-W 30x C-POL Polarizer
SMZ745
8
5
C-mount Camera
SM-S4L 4" x 4" Stage L
SMZ745T
8
C-TRS Tilting Stage 8-segment LED SMZ645 Adapter
G-AL 0.5x
G-ICIL Coaxial Episcopic Illuminator
G-AL 1.5x
G-AL 0.7x
Circular Floating Stage 2
7
C-FLED LED for Fiber Illuminator 8-segment LED Ring Light CYN-E1
C-FIR Ring Fiber Light Guide
C-FID Bifurcated Fiber Light Guide
C-POL Analyzer SM-LW61Ji C-FRL Fluorescent C-FPS Fluorescent LED Illuminator Ring Lamp 8 W Ring Illuminator
2 3
C-ER Extension Ring Adapter for 0.5x Objectives
2 3 4
2 3 C-FMAN Focusing Mount AN
C-GSP180 Glass Plate 180 mm
C-ASP180 Opal & Black Acrylic Plate 180 mm
Halogen Light for Fiber Illuminator (12 V-100 W halogen)
2 3 4
C-S4A 4" x 4" Stage Adapter
G-AL 2x
C-SSL Dia-sliding Stage
C-FMC Focusing Mount C
6
5 6 7 7 8 C-FMBN Focusing Mount BN
1 C-LEDS Hybrid LED Stand with built-in epi/diascopic illuminator
C-PS/C-PSC Plain Stands (C-PSC is not compatible with digital imaging)
C-DS Diascopic Stand S
C-EP Extension Pillar (used with auxiliary objectives 0.5x, 0.7x)
C-DS 33 mm NCB11
1
6 V-20 W Halogen Lamp, C-DSLS with reflector Illuminator Articulated Arm
2 3 6 7
Universal Table Stand US-3
G-US2 Universal Table Stand 2
G-US1 Universal Table Stand 1
5 6 7
2
C-DSS Diascopic Stand
C-DSD Diascopic Stand
6 V-30 W Halogen Lamp
164
5 6 7
2
2
5 6 7
XN (TN) Transformer
2
6 V-10 W Halogen Lamp
Light Guide C-DSDF Fiber-optic for Fiber-optic Diascopic Stand Diascopic Stand 6 V-30 W (included with stand) Halogen Lamp
C-BD Diascopic Bright/ Darkfield Stand
6 V-30 W Halogen Lamp
164
150
140
G-EIA Articulated Supporting Arm
3 4
45
SMZ745
WARNING
TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT.
Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. January 2011 ©2011 NIKON CORPORATION
305
325
292
SMZ745T
Ø60 135
135
159
W.D.=115
325
Ø60
26
292
26
159
W.D.=115
385
389
45°
Dimensional diagrams
5 6 7
2
C-PS160 Plain Stand
2
G-LS Illuminator
305
(Unit: mm)
N.B. Export of the products* in this catalog is controlled under the Japanese Foreign Exchange and Foreign Trade Law. Appropriate export procedure shall be required in case of export from Japan. *Products: Hardware and its technical information (including software) * Monitor images are simulated.
En
Stereoscopic Zoom Microscopes SMZ1000/SMZ800
Stereoscopic Zoom Microscopes
Specifications
199 (7.8)
332.5 (13.1)
54.5 (2.1)
217 (8.5) 298 (11.7)
φ60 (2.4)
339 (13.3)
Unit: mm (in)
SMZ800 Eyepoint level (interpupillary distance: 64 mm/2.5 in.)
159 (6.3)
292 (11.5)
130 (5.1)
325.5 (12.8)
199 (7.8)
φ 60 (2.4)
135 (5.3)
139 (5.5)
78 (3.1) 52 (2.0) 120 (4.7)
C-W10XA (F.N. 22), C-W15X (F.N. 16), C-W20X (F.N. 12.5), C-W30X (F.N. 7) 0.8X–8.0X 1X–6.3X 10 : 1 6. 3 : 1 P-Plan Apo 0.5X, 1X; P-ED Plan 1.5X, 2X; P-Plan 1X*; PAchro 0.5X; P-ERG Plan 1X ERGO* *Usable at zoom magnifications larger than 1X when mounted on SMZ1000. Working distance Please refer to the table on the previous page Illumination P-ICI2 Coaxial Episcopic Illuminator (12V-100W halogen) systems (Intermediate magnification is 1.5X.) G-LS 6V-10W Illuminator G-LS 6V-10W Illuminator (with Articulated Arm or G-EIA Articulated Supporting Arm) C-DSLS 6V-20W Illuminator (with Articulated Arm) C-FPS Fluorescent Ring Illuminator C-FIR Plastic Fiber-optic Ring Illuminator (12V-100W halogen) C-FID Plastic Fiber-optic Bifurcated Illuminator (12V-100W halogen) Stands C-PS Plain Focusing Stand C-PSC Compact Plain Focusing Stand C-DS Diascopic Stand S C-PS160 Plain Stand C-DSS Diascopic Stand C-DSD Diascopic Stand C-DSDF Fiber-optic Diascopic Stand C-BD Diascopic Bright/Darkfield Stand P-THS Teaching Head Stand Focusing mount C-FMC Focusing Mount C C-FMA Focusing Mount A C-FMB Focusing Mount B Photomicrographic/ Nikon Photomicrographic System FX-III Series or CCTV CCTV system camera can be attached through Beam Splitter and Adapter. Photo-tube beam-split ratio: please refer to the table on page 9. Power consumption Diascopic stands: 80W C-FPS115 Fluorescent Ring Illuminator: 24W C-FPS230 Fluorescent Ring Illuminator: 16W Fiber Transformer: 135W Note: For possible combinations of accessories, please refer to the system diagram on page 10.
408 (16.1)
P-BT Standard Binocular, P-BTL Low Eye-level Binocular, P-BERG Tilting Binocular 20˚ (Standard Binocular and Low Eye-level Binocular), 0˚–30˚ (Tilting Binocular) 48–75mm (1.9–3.0 in.)
160 (6.3)
133 (5.2)
7.5X–525X
70 (2.8)
6X–540X
30 (1.2)
Interpupillary distance adjustment Eyepieces (with diopter adjustment) Zoom range Zoom ratio Objectives
Eyepoint level (interpupillary distance: 64 mm/2.5 in.) 139 (5.5)
397 (15.6)
Eyepiece inclination
SMZ1000
26.5 (1.0)
Optical system Total magnification Varies depending on eyepiece and objective used. When coaxial episcopic illuminator is attached. Eyepiece tubes
Dimensions SMZ1000 SMZ800 Parallel-optics zoom system 4X–480X 5X–378X
305 (12)
Unit: mm (in)
Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. April 2006. ©2000-06 NIKON CORPORATION
WARNING
TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT.
En
A new era of microscopy: “Shuttle style.”
Specifications Zoom Camera Head (P-400R) Effective pixels CCD
Optics Working distance FOV Illumination
Recording
Shooting mode
Exposure
Aperture
Approx. 1.98 megapixels CCD: 1/1.8" color CCD, total pixels approx. 2.11 megapixels Frame rate: 28fps (selectable 28fps (800x600) or 15fps (1600x1200) when connected to Motorized Focusing Stand) Magnification: 3x to 60x (magnification on built-in 2.7" monitor), 20x to 400x (magnification on dedicated 17" monitor), optical zoom ratio = 20:1 29mm Maximum diagonal field of view 20mm (16mm x 12mm) Light source: white LED Illumination method: Episcopic illumination from around the objective lens Illumination area: ø20mm, 4-segment ring LED (top/bottom/left/right) Storage media: SD memory card, SDHC memory card (max. 16GB) (selectable USB memory or FTP when connected to Motorized Focusing Stand) File format: TIFF (non-compressed), JPEG (3 compression levels) Recording pixels: 2M (1600x1200), 0.5M (800x600) Scene mode (Standard, Wafer/ IC chip, Metal Ceramic, Circuit Board, FPD), BSS (Best Shot Select), timer (2 seconds fixed), interval, 4 custom setting, with focus indicator Photometry method: Average photometry/peak-hold photometry Exposure control: Program AE/shutter preferred/manual exposure Exposure compensation: -2EV to +2EV in 1/3EV steps, camera gain and shutter speed can be set (manual exposure) AE lock function Resolution preferred mode/Depth-of-focus preferred mode
Image compensation White balance LCD Monitor Image playback Image deletion Video output Connector Language Power supply
Power consumption Battery operating time Charging time Tripod socket hole Dimensions Weight Usage environment
Image quality adjustment: Saturation/hue/contrast/sharpness/color effect Shading correction: Factory setting (switchable On/Off can be switched) Manual setting (adjustable red/blue gain can be adjusted) 2.7" TFT color LCD, turned off automatically when connected to Motorized Focusing Stand Full-frame view, thumbnail view (9 frames), zoom view (scrollable) Quick delete, select image delete, folder delete, card format NTSC/PAL Video output, capture input (ø3.5mm stereo mini jack), dedicated connector for stand Japanese/English Li-ion Rechargeable Battery/AC adapter/Motorized Focusing Stand (when connected to Motorized Focusing Stand) Battery: P-Li01 P-Li-ion Rechargeable Battery AC adapter: AC adapter EA1050E-120 (optional) Auto power save: 30sec./1min./5min./10min./20min. 24VA Approx. 90 minutes (battery life at maximum power consumption by maximum LED brightness) Approx. 4 hours (when no charge rema ins) 1/4-inch (ISO 1222) Approx. 96(W)x142(H)x228(D)mm Approx. 900g (excluding battery and SD card) Temperature: 0 to +40ºC Humidity: 60% RH max. (no condensation)
Motorized Focusing Stand (P-MFSC) Stroke Stage Image Edit
Direct Printing
Z axis stroke: 150mm (upward 148mm, downward 2mm), upper and lower limit can be adjusted 3x2 Stage/Sliding Stage/Tilting Stage EDF: Still image display, 3D image display (with ShuttlePix Editor) Halation prevention: Live display (max. 5fps, 1280x960, 800x600) High dynamic range: Still image display (1280x960/800x600) Calibration: Zoom magnification conversion/user-registerd calibration Measurement function: Distance between 2 points, point-to-line distance, distance between center points of 2 circles, angle, circle, area, pitch Annotation: Count marking, text input, pen drawing, straight line, scale indication, cross-hairs, grid, XY scale, XY measurement Supported printer: PictBridge printer
Connector
Power consumption Dimensions Weight Usage environment
Camera head IF : for connection to P-400R Video output: DVI-I LAN: 10Base-T/100Base−TX USB host: USB2.0 A connector x2 (for connection to USB mouse/ USB memory/ dedicated monitor) USB device: USB2.0 B connector x1 ( for connection to PC) Japanese/English Built-in, AC100-240V 50/60Hz Auto power save: OFF/1 to 99min. 140VA Approx. 280(W)x450(H)x404(D)mm Approx. 9kg Temperature: 0 to +40ºC Humidity: 60% RH max. (no condensation)
Power supply Power consumption Dimensions Weight Usage environment
AC100-240V 50/60Hz 140VA Approx. 390(W)x371(H)x180(D)mm Approx. 7kg Temperature: 0 to +40ºC Humidity: 60% RH max. (no condensation)
Language Power supply
Touch Panel Monitor (P-TPM) Display size Resolution Connector
17.0" (display area 333.9mm x 270.3mm) SXGA (1280x1024) Image input: Digital input: DVI-D SXGA, video input: NTSC composite USB host: USB2.0 A connector x3 USB device: USB2.0 B connector x1
http://www.nikon.com/products/instruments/lineup/digital-microscope/shuttlepix/index.htm See the URL above for product details and download information regarding ShuttlePix Editor dedicated software. *Download of ShuttlePix Editor is limited to registered users of the product.
Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. October 2010 ©2010 NIKON CORPORATION N.B. Export of the products* in this catarog is controlled under the Japanese Foreign Exchange and Foreign Trade Law. Appropriate export procedure shall be required in case of export from Japan. *Products: Hardware and its technical information (including software)
Hoskin Scientific Limited has been supplying testing and monitoring instruments since 1946. Although our range is broad, we focus on three major markets including: Geotechnical & Materials Testing Environmental Monitoring Test & Measurement Instrumentation Hoskin Scientific operates out of three offices within Canada: 3735 Myrtle Street, Burnaby, BC V5C 4E7 Phone (604) 872-7894 Fax (604) 872-0281 email
[email protected] 4210 Morris Drive, Burlington, ON L7L 5L6 Phone (905) 333-5510 Fax (905) 333-4976 email
[email protected] 300 Rue Stinson, Montreal, PQ H4N 2E7 Phone (514) 735-5267 Fax (514) 735-3454 email
[email protected]