Preview only show first 10 pages with watermark. For full document please download

Microscopes For Environmental Applications

   EMBED


Share

Transcript

Microscopes for Environmental Applications Limnology Plant Science Entomology Pathology Aquatic Assessment Soil Science Chlorophyll Dissection HOSKIN SCIENTIFIC LTD. www.hoskin.ca  dĂďůĞŽĨŽŶƚĞŶƚƐ   ^ƚĞƌĞŽŽŽŵDŝĐƌŽƐĐŽƉĞƐ^Dϰϰϱͬ^DϰϲϬ  ŝŽůŽŐŝĐĂůDŝĐƌŽƐĐŽƉĞĐůŝƉƐĞϭϬϬ  ŝŽůŽŐŝĐĂůDŝĐƌŽƐĐŽƉĞĐůŝƉƐĞϮϬϬ  ^ƚĞƌĞŽƐĐŽƉŝĐDŝĐƌŽƐĐŽƉĞ^Dϳϰϱͬϳϰϱd  ^ƚĞƌĞŽƐĐŽƉŝĐŽŽŵDŝĐƌŽƐĐŽƉĞƐ^DϭϬϬϬͬ^DϴϬϬ   ^ŚƵƚƚůĞƉŝdžWͲϰϬϬZWŽƌƚĂďůĞŝŐŝƚĂůDŝĐƌŽƐĐŽƉĞ  ϱ  ϳ  ϵ  ϭϭ  ϭϯ  ϭϱ    ǁǁǁ͘ŚŽƐŬŝŶ͘ĐĂ  Twin zooming objective optical system Type 8x ~ 35x (4x ~ 70x by replacing eyepiece and/or aux iliary obje c tive le ns ) 7x ~ 30x (3.5x ∼60x by replacing eyepiece and/or aux iliary obje c tive le ns ) Eyepiece SM 10xB eyepieces (F.N. 21), SM 15xB eyepieces (F.N.14), SM 20xB eyepieces (F.N. 12) Zoom range Auxiliary objective lens 0 . 8 x ~ 3 . 5 x (Zoom ratio: 4 . 4 : 1 ) AL0.5x, 0.7x (optional) Working distance Eyepiece inclination 0 . 7 x ~ 3 x (Zoom ratio: 4 . 3 : 1 ) Optical system 45 º 60 º True erect image, 12 º inner bevel, independent adjustment of right and left eyepieces, and 54 to 75mm interpupillary adjustment Weight (Zooming body) Approx. 1.0kg Dimensions Combination with the LED Stand Combination with the LED Stand 160 160 E.P 325 120 ∼225 120 ∼225 350.5 350.5 E.P 0°∼5 5° 0°∼5 5° 200 325 200 325 366 Speci cations and equipment are subject to change without any notice or obligation on the part of the manufacturer. December 0072 ©2007 NIKON CORPORATION Biological Microscope ECLIPSE E100 Biological Microscope Specifications Optical system CFI optical system Magnification 40 –1500x Illumination 6V-20W halogen lamp, FL (field lens) unit, lamp changeable by removing the field lens unit Coarse and fine focusing Coaxial coarse/fine focusing with cross roller guide incorporated, 22mm coarse/fine focusing range, Coarse motion: 37.7mm/rotation, Fine motion: 0.2mm/rotation with 2µm scale increments, Coarse motion torque adjustable Eyepiece tube Eyepiece lens (with rubber eye guard) Condenser E2-TB binocular tube (inclination: °, 360° 30 rotatable Siedentopf-type, interpupillary distance: –75mm) 47 E2-TF trinocular tube F (2-way, inclination:°,30 360° rotatable Siedentopf-type, interpupillary distance: –75mm) 47 E1-CFI 10x (F.O.V.: 18mm), CFI E 15x (F.O.V.: 12mm) Abbe condenser, NA 1.25 (aperture diaphragm with position guide marking for respective objectives), 33mm-diameter filters attachable (including standard blue filter) Nosepiece Quadruple click-stop, revolving mechanism with multiple ball bearings, elastic nosepiece grip-ring Dedicated objectives CFI BE Plan Achromat 4x (NA 0.1/W.D. 25mm), 10x (NA 0.25/W.D. 6.7mm), 20x (NA 0.4/W.D. 3.7mm), 40x5/W.D. (NA 0.60.6mm), 60x (NA 0.8/W.D. 0.24mm), 100x (NA 1.25/W.D. 0.14mm), DL 10x (NA 0.25/W.D. 6.7), DL 40x (NA 0.65/W.D. 0.6), DL 100x (NA 1.25/W.D. 0.14) Stage Double-plate rectangular mechanical stage, stage size: 155 (W) x 134 (D)mm, removal slide holder, travel area: 76(D)mm, (W) x 40 vernier provided Adjustable vertical condenser movement range: 10mm Substage Optional accessories Phase contrast attachment (dedicated Abbe condenser, sliders, objectives (10x, 40x, 100x), GIF filter, e centering phas telescope), object marker, darkfield ring unit, mirror unit, cord hanger, storage case 50W Power consumption Weight Approx. 7.3kg Unit: mm Dimensional Diagram 204.8 378 63 190 281 374 E.P. 145.2 237 111 150 235 Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. December 2009 ©2006-09 NIKON CORPORATION WARNING TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT. * Monitor images are simulated. Company names and product names appearing in this brochure are their registered trademarks or trademarks. Biological Microscope Eclipse E200-F (model with field diaphragm) Eclipse E200 Dimensional Diagram 206.4 381.7 (When PD is 64mm.) 411.4 (Eyepoint height when PD is 64mm.) 315 407.4 (Minimum microscope height) 191.3 414.6 (When PD is 64mm.) 101.5 226.8 105 188.5 247.7 Unit: mm Optical system Eyepiece tube Eyepiece Photo lens Nosepiece focusing Stage Objectives WARNING Parfocal distance: 60mm 40–1500X for observation 8–500X for 35mm photomicrography E2-TB Binocular tube, E2-TF Trinocular tube Siedentopf type (Inclination: 30°, Interpupillary distance: 47-75 mm, 360° rotatable) C-TE Ergonomic Binocular Tube (inclination: 1030º, extension: 40mm) CFI E 10X (F.O.V.: 20mm), CFI E 15X (F.O.V.: 12mm) PLI projection lens: 2X, 2.5X, 4X, 5X Quadruple nosepiece, reversed type Fine: 0.2mm per rotation, Coarse: 37.7mm per rotation, Minimum reading: 2 microns on left-side adjustable, Refocusing system incorporated in stage, Stage handle and focusing knob are at equal distance from the operator Rectangular 216 x 150 mm surface stage mounted on the main body. Cross travel 78 x 54 mm using low-positioned X/Y coaxial control knob CFI E Plan Achromat 4X N.A. 0.10 (W.D. 30mm) CFI E Plan Achromat 10X N.A. 0.25 (W.D. 0.7mm) Condenser CFI E Plan Achromat 40X N.A. 0.65 (W.D. 0.65mm) CFI E Plan Achromat 100X Oil N.A. 1.25 (W.D. 0.23mm) As an option, CFI Achromat DL and other higher-grade CFI60 objectives can be used E2 Abbe condenser N.A. 1.25; leaf-type aperture diaphragm with position guide markings for respective CFI E Plan objectives Optional condensers: E2 Phase condenser N.A. 1.25; leaf-type aperture diaphragm with position guide markings for respective CFI Achromat DL objectives C-C Achromat Condenser Achromat Swing-out Condenser Illumination system Intermediate attachment * C-C Phase Contrast Condenser 6V-20W halogen bulb, 6V-30W halogen bulb Compliant with multi-voltage (100V-240V) head (face-to-face and side-by-side types), Drawing tube, Eye level riser * Maximum intermediate space 50mm TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT. on the part of the manufacturer. March 2010 n ©2000-10 NIKON CORPORATION 0 8-541-45 84 Stereoscopic Microscope SMZ745/745T Nikon's stereoscopic microscope with 7.5x zoom and 115 mm working distance ! a superior model in this category 7.5x zoom: extremely high zoom range The SMZ745/745T boasts a 7.5x zoom that incorporates the Greenough optical system. The zoom range of 0.67x to 5x provides a broad observation range. Trinocular optical head is ideal for monitoring and digital imaging (SMZ745T only) The SMZ745T incorporates an optical path switching lever that enables easy switchover between eyepiece and camera. Nikon Digital Sight series camera can be attached. Superior 115 mm working distance As well as high zoom ratio and magnification, the SMZ745/745T offers a long 115 mm working distance. Optical path switching lever Working distance: 115 mm With Digital Sight series camera for microscopes Three “A” design The airtight, anti-mold, anti-electrostatic design makes the SMZ745 suitable for use in a range of working environments. * The SMZ745T has an anti-mold, antielectrostatic design. Specifications SMZ745 SMZ745T Optical system Greenough optical system Total magnification 3.35-300x (depending on eyepiece and auxiliary objective used) Vertical tube Built-in C-mount 0.55x magnification lens (F.N. 11), compatible with 2/3 in. or smaller CCD Eyepiece tube Fixed type Eyepiece inclination 45 ° Interpupillary distance adjustment 52-75 mm Eyepieces (with diopter adjustment) C-W 10xB (F.N. 22), C-W 15x (F.N. 16), C-W 20x (F.N. 12.5), C-W 30x (F.N. 7) Zoom range 0.67-5x Zoom ratio 7.5:1 Auxiliary objectives G-AL 0.5x (W.D. 211 mm), G-AL 0.7x (W.D. 150 mm), G-AL 1.5x (W.D. 61 mm), G-AL 2x (W.D. 43.5 mm) Working distance 115 mm (standard) Weight 1.55 kg (SMZ745), 1.8 kg (SMZ745T) F.N.: Field Number System diagrams Rubber Eyeguard SM Opal & Black Acrylic Plate Horn-shaped Eyeguard C-FC Crosshairs C-FM Micrometer SMZ Glass Plate ESD Plate C-W 10xB C-W 15x C-W 20x C-W 30x C-POL Polarizer SMZ745 8 5 C-mount Camera SM-S4L 4" x 4" Stage L SMZ745T 8 C-TRS Tilting Stage 8-segment LED SMZ645 Adapter G-AL 0.5x G-ICIL Coaxial Episcopic Illuminator G-AL 1.5x G-AL 0.7x Circular Floating Stage 2 7 C-FLED LED for Fiber Illuminator 8-segment LED Ring Light CYN-E1 C-FIR Ring Fiber Light Guide C-FID Bifurcated Fiber Light Guide C-POL Analyzer SM-LW61Ji C-FRL Fluorescent C-FPS Fluorescent LED Illuminator Ring Lamp 8 W Ring Illuminator 2 3 C-ER Extension Ring Adapter for 0.5x Objectives 2 3 4 2 3 C-FMAN Focusing Mount AN C-GSP180 Glass Plate 180 mm C-ASP180 Opal & Black Acrylic Plate 180 mm Halogen Light for Fiber Illuminator (12 V-100 W halogen) 2 3 4 C-S4A 4" x 4" Stage Adapter G-AL 2x C-SSL Dia-sliding Stage C-FMC Focusing Mount C 6 5 6 7 7 8 C-FMBN Focusing Mount BN 1 C-LEDS Hybrid LED Stand with built-in epi/diascopic illuminator C-PS/C-PSC Plain Stands (C-PSC is not compatible with digital imaging) C-DS Diascopic Stand S C-EP Extension Pillar (used with auxiliary objectives 0.5x, 0.7x) C-DS 33 mm NCB11 1 6 V-20 W Halogen Lamp, C-DSLS with reflector Illuminator Articulated Arm 2 3 6 7 Universal Table Stand US-3 G-US2 Universal Table Stand 2 G-US1 Universal Table Stand 1 5 6 7 2 C-DSS Diascopic Stand C-DSD Diascopic Stand 6 V-30 W Halogen Lamp 164 5 6 7 2 2 5 6 7 XN (TN) Transformer 2 6 V-10 W Halogen Lamp Light Guide C-DSDF Fiber-optic for Fiber-optic Diascopic Stand Diascopic Stand 6 V-30 W (included with stand) Halogen Lamp C-BD Diascopic Bright/ Darkfield Stand 6 V-30 W Halogen Lamp 164 150 140 G-EIA Articulated Supporting Arm 3 4 45 SMZ745 WARNING TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT. Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. January 2011 ©2011 NIKON CORPORATION 305 325 292 SMZ745T Ø60 135 135 159 W.D.=115 325 Ø60 26 292 26 159 W.D.=115 385 389 45° Dimensional diagrams 5 6 7 2 C-PS160 Plain Stand 2 G-LS Illuminator 305 (Unit: mm) N.B. Export of the products* in this catalog is controlled under the Japanese Foreign Exchange and Foreign Trade Law. Appropriate export procedure shall be required in case of export from Japan. *Products: Hardware and its technical information (including software) * Monitor images are simulated. En Stereoscopic Zoom Microscopes SMZ1000/SMZ800 Stereoscopic Zoom Microscopes Specifications 199 (7.8) 332.5 (13.1) 54.5 (2.1) 217 (8.5) 298 (11.7) φ60 (2.4) 339 (13.3) Unit: mm (in) SMZ800 Eyepoint level (interpupillary distance: 64 mm/2.5 in.) 159 (6.3) 292 (11.5) 130 (5.1) 325.5 (12.8) 199 (7.8) φ 60 (2.4) 135 (5.3) 139 (5.5) 78 (3.1) 52 (2.0) 120 (4.7) C-W10XA (F.N. 22), C-W15X (F.N. 16), C-W20X (F.N. 12.5), C-W30X (F.N. 7) 0.8X–8.0X 1X–6.3X 10 : 1 6. 3 : 1 P-Plan Apo 0.5X, 1X; P-ED Plan 1.5X, 2X; P-Plan 1X*; PAchro 0.5X; P-ERG Plan 1X ERGO* *Usable at zoom magnifications larger than 1X when mounted on SMZ1000. Working distance Please refer to the table on the previous page Illumination P-ICI2 Coaxial Episcopic Illuminator (12V-100W halogen) systems (Intermediate magnification is 1.5X.) G-LS 6V-10W Illuminator G-LS 6V-10W Illuminator (with Articulated Arm or G-EIA Articulated Supporting Arm) C-DSLS 6V-20W Illuminator (with Articulated Arm) C-FPS Fluorescent Ring Illuminator C-FIR Plastic Fiber-optic Ring Illuminator (12V-100W halogen) C-FID Plastic Fiber-optic Bifurcated Illuminator (12V-100W halogen) Stands C-PS Plain Focusing Stand C-PSC Compact Plain Focusing Stand C-DS Diascopic Stand S C-PS160 Plain Stand C-DSS Diascopic Stand C-DSD Diascopic Stand C-DSDF Fiber-optic Diascopic Stand C-BD Diascopic Bright/Darkfield Stand P-THS Teaching Head Stand Focusing mount C-FMC Focusing Mount C C-FMA Focusing Mount A C-FMB Focusing Mount B Photomicrographic/ Nikon Photomicrographic System FX-III Series or CCTV CCTV system camera can be attached through Beam Splitter and Adapter. Photo-tube beam-split ratio: please refer to the table on page 9. Power consumption Diascopic stands: 80W C-FPS115 Fluorescent Ring Illuminator: 24W C-FPS230 Fluorescent Ring Illuminator: 16W Fiber Transformer: 135W Note: For possible combinations of accessories, please refer to the system diagram on page 10. 408 (16.1) P-BT Standard Binocular, P-BTL Low Eye-level Binocular, P-BERG Tilting Binocular 20˚ (Standard Binocular and Low Eye-level Binocular), 0˚–30˚ (Tilting Binocular) 48–75mm (1.9–3.0 in.) 160 (6.3) 133 (5.2) 7.5X–525X 70 (2.8) 6X–540X 30 (1.2) Interpupillary distance adjustment Eyepieces (with diopter adjustment) Zoom range Zoom ratio Objectives Eyepoint level (interpupillary distance: 64 mm/2.5 in.) 139 (5.5) 397 (15.6) Eyepiece inclination SMZ1000 26.5 (1.0) Optical system Total magnification Varies depending on eyepiece and objective used. When coaxial episcopic illuminator is attached. Eyepiece tubes Dimensions SMZ1000 SMZ800 Parallel-optics zoom system 4X–480X 5X–378X 305 (12) Unit: mm (in) Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. April 2006. ©2000-06 NIKON CORPORATION WARNING TO ENSURE CORRECT USAGE, READ THE CORRESPONDING MANUALS CAREFULLY BEFORE USING YOUR EQUIPMENT. En ฀ ฀ A new era of microscopy: “Shuttle style.” ฀ ฀ Specifications Zoom Camera Head (P-400R) Effective pixels CCD Optics Working distance FOV Illumination Recording Shooting mode Exposure Aperture Approx. 1.98 megapixels CCD: 1/1.8" color CCD, total pixels approx. 2.11 megapixels Frame rate: 28fps (selectable 28fps (800x600) or 15fps (1600x1200) when connected to Motorized Focusing Stand) Magnification: 3x to 60x (magnification on built-in 2.7" monitor), 20x to 400x (magnification on dedicated 17" monitor), optical zoom ratio = 20:1 29mm Maximum diagonal field of view 20mm (16mm x 12mm) Light source: white LED Illumination method: Episcopic illumination from around the objective lens Illumination area: ø20mm, 4-segment ring LED (top/bottom/left/right) Storage media: SD memory card, SDHC memory card (max. 16GB) (selectable USB memory or FTP when connected to Motorized Focusing Stand) File format: TIFF (non-compressed), JPEG (3 compression levels) Recording pixels: 2M (1600x1200), 0.5M (800x600) Scene mode (Standard, Wafer/ IC chip, Metal Ceramic, Circuit Board, FPD), BSS (Best Shot Select), timer (2 seconds fixed), interval, 4 custom setting, with focus indicator Photometry method: Average photometry/peak-hold photometry Exposure control: Program AE/shutter preferred/manual exposure Exposure compensation: -2EV to +2EV in 1/3EV steps, camera gain and shutter speed can be set (manual exposure) AE lock function Resolution preferred mode/Depth-of-focus preferred mode Image compensation White balance LCD Monitor Image playback Image deletion Video output Connector Language Power supply Power consumption Battery operating time Charging time Tripod socket hole Dimensions Weight Usage environment Image quality adjustment: Saturation/hue/contrast/sharpness/color effect Shading correction: Factory setting (switchable On/Off can be switched) Manual setting (adjustable red/blue gain can be adjusted) 2.7" TFT color LCD, turned off automatically when connected to Motorized Focusing Stand Full-frame view, thumbnail view (9 frames), zoom view (scrollable) Quick delete, select image delete, folder delete, card format NTSC/PAL Video output, capture input (ø3.5mm stereo mini jack), dedicated connector for stand Japanese/English Li-ion Rechargeable Battery/AC adapter/Motorized Focusing Stand (when connected to Motorized Focusing Stand) Battery: P-Li01 P-Li-ion Rechargeable Battery AC adapter: AC adapter EA1050E-120 (optional) Auto power save: 30sec./1min./5min./10min./20min. 24VA Approx. 90 minutes (battery life at maximum power consumption by maximum LED brightness) Approx. 4 hours (when no charge rema ins) 1/4-inch (ISO 1222) Approx. 96(W)x142(H)x228(D)mm Approx. 900g (excluding battery and SD card) Temperature: 0 to +40ºC Humidity: 60% RH max. (no condensation) Motorized Focusing Stand (P-MFSC) Stroke Stage Image Edit Direct Printing Z axis stroke: 150mm (upward 148mm, downward 2mm), upper and lower limit can be adjusted 3x2 Stage/Sliding Stage/Tilting Stage EDF: Still image display, 3D image display (with ShuttlePix Editor) Halation prevention: Live display (max. 5fps, 1280x960, 800x600) High dynamic range: Still image display (1280x960/800x600) Calibration: Zoom magnification conversion/user-registerd calibration Measurement function: Distance between 2 points, point-to-line distance, distance between center points of 2 circles, angle, circle, area, pitch Annotation: Count marking, text input, pen drawing, straight line, scale indication, cross-hairs, grid, XY scale, XY measurement Supported printer: PictBridge printer Connector Power consumption Dimensions Weight Usage environment Camera head IF : for connection to P-400R Video output: DVI-I LAN: 10Base-T/100Base−TX USB host: USB2.0 A connector x2 (for connection to USB mouse/ USB memory/ dedicated monitor) USB device: USB2.0 B connector x1 ( for connection to PC) Japanese/English Built-in, AC100-240V 50/60Hz Auto power save: OFF/1 to 99min. 140VA Approx. 280(W)x450(H)x404(D)mm Approx. 9kg Temperature: 0 to +40ºC Humidity: 60% RH max. (no condensation) Power supply Power consumption Dimensions Weight Usage environment AC100-240V 50/60Hz 140VA Approx. 390(W)x371(H)x180(D)mm Approx. 7kg Temperature: 0 to +40ºC Humidity: 60% RH max. (no condensation) Language Power supply Touch Panel Monitor (P-TPM) Display size Resolution Connector 17.0" (display area 333.9mm x 270.3mm) SXGA (1280x1024) Image input: Digital input: DVI-D SXGA, video input: NTSC composite USB host: USB2.0 A connector x3 USB device: USB2.0 B connector x1 http://www.nikon.com/products/instruments/lineup/digital-microscope/shuttlepix/index.htm See the URL above for product details and download information regarding ShuttlePix Editor dedicated software. *Download of ShuttlePix Editor is limited to registered users of the product. Specifications and equipment are subject to change without any notice or obligation on the part of the manufacturer. October 2010 ©2010 NIKON CORPORATION N.B. Export of the products* in this catarog is controlled under the Japanese Foreign Exchange and Foreign Trade Law. Appropriate export procedure shall be required in case of export from Japan. *Products: Hardware and its technical information (including software) Hoskin Scientific Limited has been supplying testing and monitoring instruments since 1946. Although our range is broad, we focus on three major markets including: Geotechnical & Materials Testing Environmental Monitoring Test & Measurement Instrumentation Hoskin Scientific operates out of three offices within Canada: 3735 Myrtle Street, Burnaby, BC V5C 4E7 Phone (604) 872-7894 Fax (604) 872-0281 email [email protected] 4210 Morris Drive, Burlington, ON L7L 5L6 Phone (905) 333-5510 Fax (905) 333-4976 email [email protected] 300 Rue Stinson, Montreal, PQ H4N 2E7 Phone (514) 735-5267 Fax (514) 735-3454 email [email protected]