Transcript
MicroSquare
Installation Instructions, Pendant aircraft cable mount Page 1 of 4 Aircraft 1. Install ceiling-level mounting components. 2. Hang end caps from the aircraft cable at both ends of the row. 3. Hang joiners (where applicable for multiple-luminaire rows). Figure B 4. Trim excess aircraft cable. 5. Attach the first luminaire to the end cap. Secure with set screws (provided). 6. Continue to install the remaining luminaires in the same row (where applicable) 7. Snap the non-powered end cap to the luminaire at the end of the row. A Secure with set screws (provided). Figure A 8. Level entire row. 9. Tighten all set screws. 10. Connect power cord from the powered end cap into the j-box in the ceiling in accordance with the local and national electrical code. Figure C
Top view
B
B Bottom view
A
C
C
Set screw Set screw
Aircraft cable
Cable gripper
3.75" Hang clip
Hang clip
Figure A
© 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice.
IS_MicroSquare 03/13
Male plug End cap
Figure B
Figure C
2"
Cross section view
MicroSquare
Installation Instructions, Pendant pipe mount Page 2 of 4 Pendant Pipe 1. Install ceiling-level mounting components 2. Thread end cap pendant assemblies into mounting swivel ball. Feed power wires up into the pendant pipe at j-box location. Ensure all exposed conductors remain covered with fiberglass sleeve. Figure A 3. Thread joiners (where applicable for multiple luminaire rows) into mounting A swivel ball. Figure B 4. Attach the first luminaire to the end cap. Secure with set screws (provided) 5. Continue to install the remaining luminaires in the same row (where applicable) 6. Snap the non-powered end cap to the luminaire at the end of the row. Secure with set screws (provided). Figure C 7. Level entire row by supporting luminaire and rotating the mounting swivel ball 8. Tighten all set screws 9. Connect power conductors from theC pendant pipe into the j-box in the ceiling in accordance with the local and national electrical code
Top view
B
B Bottom view
A
C
Set screw
Set screw
Non-powered pendant pipe
Powered pendant pipe
Power conductors covered with fiberglass sleeve
3.75"
Male plug End cap
Figure A
© 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires IS_MicroSquare 03/13
Figure B
Figure C
2"
Cross section view
MicroSquare
Installation Instructions, Wall mount Page 3 of 4 Wall Mount 1. Determine vertical location of luminaires. Draw a reference line on the wall, corresponding to the lower edge of the luminaire. Figure A 2. Install wall brackets as follows, Figure B: a. Vertically, the bottom of wall brackets to be ¾” above the reference line b. Horizontally, the wall brackets to be installed between 4” and 12” from the end of luminaires and approximately every 48” inrun. Note: Wall brackets must be secured to structure (e.g. studs or cross-braces) 3. Route power cord from the end cap through J-box cover (provided by others) and complete the electrical connection in accordance with the local and national electrical code. Figure C 4. Lift and hang the first luminaire on the wall brackets. 5. Hang remaining luminaires, securing together with set screws provided. Figure D 6. Level luminaires using the wall bracket Tilt Screws, and secure using the wall bracket Lock Screws. Figure E 7. Attach end caps to both ends. Tighten using set screws provided.
4" to 12" from end or joint
Top view
Reference line (bottom of fixtures)
Front view Figure A
Lock screw Tilt screw
Bottom mounting brackets to be 3/4" above reference line.
Attach brackets to wall (screws by others)
Figure B
Figure E
Wall
Power feed from wall
2"
3.75"
J-box (by others)
Connect wires inside J-box End cap male end with power cord
Figure C
© 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com/luminaires IS_MicroSquare 03/13
J-box cover (by others)
Figure D
MicroSquare
Installation Instructions, Surface mount Page 4 of 4 Surface Mount 1. Attach T-bar clips at the mounting locations. At the power drop location, install J-box (by others) using hardware and components provided. Figure A 2. Install the first mounting bracket. Do not fully tighten the nut. 3. Install the first fixture by engaging one end into the mounting bracket. Tilt the other end of fixture up. Figure B 4. Install the second mounting bracket to hold the fixture up on both ends. Do not fully tighten the nut. Figure C 5. Continue to install the remaining fixtures as above. 6. Install the end caps. 7. Feed the power cord of power-end cap through the J-box fitting into the J-box and make the electrical connection in accordance with the local and national electrical code. Figure D 8. Once completed row is hanging, tighten the mount bracket nuts to level the row. 9. Push the fixtures flush together and tighten the set screws. Figure E
Figure B
Figure C
J-box mount strap T-Bar clip
Mount bracket
J-box fitting
Mount bracket nut
2"
Figure A
© 2013 Koninklijke Philips Electronics N.V. All rights reserved. Specifications are subject to change without notice. IS_MicroSquare 03/13
Set screw
3.75" Power-End end cap
Figure D
Figure E
Philips Lighting Company 200 Franklin Square Drive Somerset, NJ 08873 Phone: 855-486-2216
Philips Lighting Company 281 Hillmount Road Markham ON, Canada L6C 2S3 Phone: 855-486-2216
www.philips.com/luminaires