Preview only show first 10 pages with watermark. For full document please download

Midspan Power Over Ethernet Controller User

   EMBED


Share

Transcript

ADCP-92-055 Issue 6 January 2006 Midspan Power over Ethernet Controller User Manual 19621-B 1355330 Rev A ADCP-92-055 • Issue 6 • January 2006 • Preface COPYRIGHT © 2006, ADC Telecommunications, Inc. All Rights Reserved Printed in the U.S.A. REVISION HISTORY ISSUE DATE 1 08/2004 REASON FOR CHANGE 2 09/2004 Update UL mark requirements 3 11/2004 Change to redundant power option. 4 02/2005 Update mounting information 5 09/2005 Add grounding information and Dual Compliant information. 6 01/2006 Add 1000Base-T model Original release. LIST OF CHANGES The technical changes incorporated into this issue are listed below. PAGE IDENTIFIER All --- DESCRIPTION OF CHANGE 1000Base-T product information TRADEMARK INFORMATION ADC and ADC Telecommunications are registered trademarks of ADC Telecommunications, Inc. Telcordia is a registered trademark of Telcordia Technologies, Inc. DISCLAIMER OF LIABILITY Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC’s Technical Assistance Center at 1-800-366-3891, extension 73475 (in U.S.A. or Canada) or 952-917-3475 (outside U.S.A. and Canada), or by e-mail to [email protected]. ADC Telecommunications, Inc. P.O. Box 1101, Minneapolis, Minnesota 55440-1101 In U.S.A. and Canada: 1-800-366-3891 Outside U.S.A. and Canada: (952) 938-8080 Fax: (952) 917-1717 Page ii ADCP-92-055 • Issue 6 • January 2006 • Preface TABLE OF CONTENTS Content Page ABOUT THIS MANUAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Related Publications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v ADMONISHMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v GENERAL SAFETY PRECAUTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi FCC COMPLIANCE STATEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vi LIST OF ACRONYMS AND ABBREVIATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii 1 2 INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.1 Power over Ethernet Midspan Controller Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.2 Power over Ethernet Front View Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1.3 LEDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 1.4 Power over Ethernet Rear View Detail . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 INSTALLING THE POWER OVER ETHERNET CHASSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.2 Rack Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2.3 AC Power Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2.4 Chassis Ground . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3 POWERING UP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 4 ETHERNET CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 5 4.1 Data & Power Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 4.2 Data Ports . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 COMMUNICATION/DAISY-CHAIN PORTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 5.1 Com IN Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 5.2 Com OUT Port . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 6 MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 7 SPECIFICATIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 8 REPLACING POWER SUPPLY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 9 OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 10 TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 11 SNMP – WEB MANAGEMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19 12 CUSTOMER INFORMATION AND ASSISTANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 9.1 Start Up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15 Page iii © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 • Preface TABLE OF CONTENTS Content Page Blank Page iv © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 • Preface ABOUT THIS MANUAL ADC’s Midspan Power over Ethernet (PoE) Controller eliminates the need to run power for IP telephones, wireless LAN Access Points, webcams and other Powered Data Terminal Equipment (PDTE) at the end of the LAN line, without modifing existing Ethernet infrastructure. Installers need to run only a single Ethernet Cat 5, 5E, or 6 cable to carry both power and data to each device. This allows greater flexibility in locating of network devices and significantly decreases installation costs in many cases. ADC’s Midspan Power over Ethernet (PoE) Controller is IEEE802.3af compliant. ADC’s Midspan Power over Ethernet (PoE) Controller is designed for use within a building not for use with a MAN (Metropolitan Area Network). To assure continued operation in the unlikely chance that a power supply should fail the Midspan Power over Ethernet (PoE) Controller is available with an optional redundant power supply. RELATED PUBLICATIONS Alternate translations of the Midspan Power over Ethernet Controller User Manual are available on the ADC website for a copy go to http://www.adc.com/ and search for ADCP-92-055*. Title/Description ADCP Number Manuel d'utilisation pour contrôleur d'injecteur d'alimentation sur Ethernet Benutzerhandbuch für Midspan Power-over-Ethernet Steuerungen (PoE) Manual del Usuario para el Controlador Midspan de Alimentación sobre Ethernet (PoE) 92-055(F) 92-055(G) 92-055(S) Listed below are related manuals and their publication numbers. Copies of these publications can be ordered by contacting ADC Technical Assistance Center see Customer Information and Assistance on page 20 for contact information. Title/Description Power over Ethernet Communications Specification ADCP Number 92-066 ADMONISHMENTS Important safety admonishments are used throughout this manual to warn of possible hazards to persons or equipment. An admonishment identifies a possible hazard and then explains what may happen if the hazard is not avoided. The admonishments — in the form of Dangers, Warnings, and Cautions — must be followed at all times. These warnings are flagged by use of the triangular alert icon (seen below) and are listed in descending order of severity of injury or damage and likelihood of occurrence. Danger: Danger is used to indicate the presence of a hazard that will cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Page v © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 • Preface Warning: Warning is used to indicate the presence of a hazard that can cause severe personal injury, death, or substantial property damage if the hazard is not avoided. Caution: Caution is used to indicate the presence of a hazard that will or can cause minor personal injury or property damage if the hazard is not avoided. GENERAL SAFETY PRECAUTIONS Warning: Wet conditions increase the potential for receiving an electrical shock when installing or using electrically-powered equipment. To prevent electrical shock, never install or use electrical equipment in a wet location or during a lightning storm. CERTIFICATION The Midspan Ethernet Power over Controller has been tested and found to comply with the requirements of UL/EN 60950. The Midspan Power over Ethernet Controller has been tested and found to comply with all applicable EU Directives. FCC COMPLIANCE STATEMENT ADC’s Midspan Power over Ethernet Controller has been certified to comply with the requirements for class A computing devices per part 15 of the FCC regulations. Warning: This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause interference to radio communications. It has been tested and found to comply with limits for a Class A digital device pursuant to Subpart A of Part 15 of FCC Rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference to TV and radio reception in which case the user, at their own expense, will be required to take whatever measures may be required to correct the interference. This equipment does not exceed Class A limits for radio emission for digital apparatus, set out in the radio interference regulation of the authorization methods of Industry Canada. Operation in a residential area may cause unacceptable interference to TV and radio reception requiring the owner or operator to take whatever steps are necessary to correct the interference. Page vi © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 • Preface LIST OF ACRONYMS AND ABBREVIATIONS The acronyms and abbreviations used in this manual are detailed in the following list: 10BaseT 100BaseTX 1000BaseT AWG C CPU DCE DTE F LAN LED IP Mbps PD PDTE PoE PSE RU RX SNMP TX UTP 10 Mb/s Ethernet Interface, per IEEE-802.3 100 Mb/s Ethernet Interface, per IEEE-802.3 1000 Mb/s Ethernet Interface, per IEEE-802.3 American Wire Gauge Centigrade Central Processor Unit Data Communications Equipment Data Terminal Equipment Fahrenheit Local Area Network Light Emitting Diode Internet Protocol Megabits per second Powered Device Powered Data Terminal Equipment Power over Ethernet Power Sourcing Equipment Rack Unit Receive Simple Network Management Protocol Transmit Unshielded Twisted Pair Page vii © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 • Preface Blank Page viii © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 1 INTRODUCTION ADC’s PoE is not a data hub or switch. ADC’s PoE adds 48VDC to the pairs (4/5 and 7/8) of the Ethernet data path that is then fed to power devices. ADC’s PoE is designed for use with standard 10Base-T, 100Base-TX, or 1000Base-T Ethernet over 8-wire Cat 5, 5E, or 6 cable. ADC’s PoE Midspan Controller is available with 8-, 16-, or 24-ports. An optional CPU is available for use when SNMP is required. CPU card is hot-swappable allowing card to be inserted into a powered chassis. ADC’s PoE normally powers devices that are enabled for power over LAN or are equipped to receive power over Ethernet. These devices are called Powered Devices (PD) or Powered Data Terminal Equipment (PDTE). Devices not equipped to receive power over Ethernet must have local power. 1.1 Power over Ethernet Midspan Controller Features • • • • • • • • • • • 1.2 Supply power to remote Ethernet terminals Eliminates the need for AC power at remote Ethernet terminals Universal power input (100-240 VAC 50/60 Hz) 15.4 Watts (48 VDC) available to each port Optional SNMP management Redundant power supply option (Hot swappable) Up to five chassis may be daisy-chained together using a single IP address for SNMP communications Independent overload and short-circuit protection on each channel Individual port status indicators Standard 19-inch rack mounting (Optional extender brackets for 23-inch rack mounting) Replaceable AC-DC power supplies Power over Ethernet Front View Detail Data and power output ports are the upper ones as shown in Figure 1. Each PoE has 8, 16, or 24 data and power ports configured as Media Dependent Interface (MDI) non-crossover. These ports are designed to carry 10Base-T or 100Base-TX Ethernet data over the standard 2-wire pairs (RJ-45 pins 1/2 and 3/6) or 1000Base-T Ethernet data over all four pairs. DC power is carried over wire pairs (RJ-45 pins 4/5 and 7/8). Data input is through the lower ports as shown in Figure 1. All ports are designed to carry 10Base-T and 100Base-TX Ethernet data (TX/RX) over the standard 2-wire pairs (RJ-45 pins 1/2 and 3/6) or 1000Base-T Ethernet data over all four pairs. The Com IN port provides two functions. First it is used as a Console port for configuration of the CPU-SNMP linecard. Second it is used as the Com IN port for chassis daisy-chaining. This connector is an industry standard DB-9 receptacle. Com IN port may be used to obtain port status information when there is no CPU SNMP linecard installed. Com OUT port is an industry standard DB-9 plug used for chassis daisy-chaining only. Any combination of up to five PoE Chassis may be controlled using one IP address and one CPU. Page 1 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 Caution: ADC’s PoE Midspan Controller is not a repeater. The maximum distance from an Ethernet switch to Data Terminal Equipment (DTE) must not exceed 100 meters (328 ft.). DATA AND POWER PORTS 20154-A COM IN DATA PORTS PORT LEDs COM OUT POWER LED Figure 1. PoE Front View (Shown with redundant power supply) 1.3 LEDS LEDs on the front indicate status of the PoE and its ports. One bi-color (green/yellow) LED for each port provides port status. A green port status LED indicates that the network equipment has been identified as Power Over LAN enabled, is active, and sending power. A yellow port status LED indicates that the network equipment has been identified as Power over LAN enabled, but is not sending power. In the event that a piece of Ethernet equipment that is not Power Over LAN enabled is connected to the PoE (indicated by LED being off), the Ethernet equipment is unaffected because power is not being supplied. Table 1 contain ethernet status information as presented by the LED during normal operation. Table 1. Ethernet Port LED Indicators LED COLOR PORT LOAD CONDITIONS PORT VOLTAGE Off Non-compliant device attached, or unplugged port. Power to the port is off. No DC voltage is present on the spare pairs. Green Device at remote is plugged in. Continuous nominal DC voltage is present on the spare pairs. Yellow Compliant device at remote is plugged in. Device at remote is present but not powered. Flashing Yellow Compliant device at remote is plugged in. Power to compliant device is disabled by CPU. Page 2 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 A power LED on the front panel, indicated by ON, provides the PoE status. ON LED illuminating green indicates that PoE is powered and operating properly. ON LED illuminating red indicates a power supply fault. Table 2 contains PoE power information as presented by LEDs during normal operation. For LED troubleshooting information see Section 10, Troubleshooting. Table 2. Power LED Indicators LED COLOR POWER SUPPLY LEDS REMARKS FRONT LED Off Internal power supply unit is unplugged or faulty. Internal power supply voltage is too low or no AC input. Green Normal operating condition. Internal power supply voltage is within tolerance. Red Internal power supply problem. Power supply fault or built-in self-test failed. REAR LED 1.4 Green AC OK AC power supply is within tolerance. Amber O.T.P. Power supply exceeded maximum operating temperature. Power over Ethernet Rear View Detail An AC Power Receptacle and ON/OFF switch is part of each power supply located at the back of the chassis. If only one power supply is used a blank cover is used to cover the other slot when it is not in use. The PoE automatically adjusts its power setting to any supply voltage in the range 100 – 240VAC (50/60 Hz). A rear view of the PoE is shown on Figure 2. ON/OFF SWITCH ON/OFF SWITCH 20160-C GROUND STUD CPU LOCATION AC POWER IN Figure 2. PoE Rear View (Shown with redundant power supply) A slot in the back of the PoE is used for the optional Central Processing Unit (CPU). A blank cover is used to cover this slot when it is not in use. Page 3 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 2 2.1 INSTALLING THE POWER OVER ETHERNET CHASSIS Unpacking and Inspection Unpack and inspect the various components as follows: 1. Inspect the exterior of the shipping container(s) for evidence of rough handling that may have damaged the components in the container. 2. Unpack each container while carefully checking the contents for damage and verify with the packing slip. 3. If damage is found or parts are missing, file a claim with the commercial carrier and notify ADC Customer Service. Save the damaged cartons for inspection by the carrier. 4. Refer to Section 12, Customer Information and Assistance if you need to contact ADC. 5. Save all shipping containers for use if the equipment requires shipment at a future date. The following procedures provide the necessary instructions for installing and wiring a Power over Ethernet Chassis in an equipment rack. 2.2 Rack Installation Mounting brackets and mounting screws are shipped loose. Mounting brackets are positioned for 19-inch rack installation (Optional extender brackets available for 23-inch rack mounting.) Adjustable mounting brackets allow chassis to be installed flush with the equipment rack face or at a depth of two-inches. Do not obstruct ventilation vents on the chassis. Caution: When mounting the PoE chassis in the rack make sure mechanical loading is even to avoid a hazardous condition, such as loading heavy equipment in the rack unevenly. The rack should safely support the combined weight of all equipment installed in it. Warning: To prevent electrical shock, never install chassis in a wet location or during a lightning storm. Before making any connections verify that input power source is off (switch in the OFF position or AC plug removed). If PoE chassis is installed in a closed or multi-rack assembly, operating temperature of the rack environment may be greater than the ambient temperature. Install PoE chassis in an environment that is compatible with the maximum rated ambient temperature. See Section 7 Specifications. Caution: Installation of the PoE chassis in a rack without sufficient air flow may result in unsafe operation. Note: Install PoE chassis in the equipment rack so that forced air by the chassis does not compromise safe operation. This procedure provides instructions for installing the chassis in an EIA or WECO 19 or 23inch equipment rack. Check the work order to determine the chassis location in the rack and the mounting, flush or recessed. Page 4 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 1. Obtain the following tools and equipment: • Flat blade or Phillips screwdriver (type to match mounting screws) • Locate mounting hardware provided. 2. Determine what rack size is being used and what recess is required. Use four (8-32 x 0.375 inch screws and four formed washers) provided to attach wide side of mounting bracket to the chassis (wide side of brackets point to the rear of chassis and narrow side of the brackets are perpendicular to the sides of the chassis). See Figure 3. Torque these screws to approximately 7–8 pound-inches (0.8–0.9 Newton meters). If installing in a 23-inch rack the optional ADC extender bracket kit EB-17B is required between the mounting bracket and the rack. 8-32 x 0.375 IN. SCREWS (8 PLACES) FORMED WASHERS (8 PLACES) 20161-B MOUNTING BRACKET (2 PLACES) Figure 3. Chassis Mounting Bracket Installation 3. Locate the equipment rack mounting space that is specified for the chassis. Note: Total cable distance between switch and data terminal equipment should not exceed 100 meters (328 feet). 4. Place the chassis in the assigned mounting space and align the holes in the mounting brackets with the holes in the equipment rack. See Figure 4. 5. Secure chassis mounting brackets to equipment rack using the mounting hardware provided. Torque screws to approximately 27 pound-inches (3.1 Newton meters). Page 5 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 20155-A MOUNTING SCREWS (2 PLACES EACH SIDE) Figure 4. Installing Chassis 2.3 AC Power Connection Warning: Follow basic electricity safety measures when connecting the PoE to a power source. The PoE chassis should be grounded. Ensure that power source is connected to earth ground during normal use. Warning: This product relies on the building wiring and distribution panels for short-circuit (overcurrent) protection. Make sure circuit is fused per local practices and codes. Warning: When connecting the PoE to the supply circuit, be sure to check PoE nameplate ratings to avoid overloading circuits which may cause damage to over-current protection devices and supply wiring. Note: Be sure to maintain reliable earthing (grounding) for rack mounting equipment. Pay particular attention to supply connections. Verify that power switch on chassis is in the OFF position. Plug one end of power cord into chassis power receptacle and the other end into the AC outlet. Repeat this process, if a redundant power supply is installed in the chassis. 2.4 Chassis Ground Caution: When connecting the equipment to the power sources, check the equipment nameplate rating to avoid overloading circuits which may cause damage to over-current protection devices and supply wiring. Page 6 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 Warning: Follow basic electricity safety measures when connecting the chassis to a power source. The chassis should be grounded. Ensure that power source is connected to earth ground during normal use. This procedure establishes a ground connection between the chassis and the office ground connection. Frame ground termination (M4 screw) is provided on the chassis, for a frame ground connection, see Figure 5. This connection must be made in accordance with all local and national electrical codes. Be sure to maintain reliable earthing (grounding) for rack mounted equipment. Pay particular attention to supply connections. 1. Using AWG 16 (1.25mm) solid copper wire, connect one end of the ground wire to a ground stud on the chassis (shown in Figure 5). Torque ground nut to approximately 15 pound-inches (1.7 Newton meters). 2. To assure proper operation the Frame Ground stud should be connected to a good earth ground. There must be no switching or disconnecting devices in the grounding circuit conductor between the power source and the point of connection to the grounding electrode conductor. 3. Connect the other end of the ground wire to the office ground conductor. Ensure this connection is made using methods and hardware that meets all applicable local and national electrical codes. ON/OFF SWITCH ON/OFF SWITCH 20160-C GROUND STUD CPU LOCATION AC POWER IN Figure 5. Chassis Ground Location 3 POWERING UP Move on/off switch(es) to ON position. PoE powers up and internal fan begins operating. PoE then runs through a power-on self-test, which takes a few seconds. During self-test, all ports on the PoE are disabled and the front panel LEDs light in the following sequence: 1. ON LED lights (green). 2. All Port LEDs and the ON LED light for an LED test (green). Page 7 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 3. All Port LEDs light yellow and the ON LED lights green for an LED test. 4. ON LED lights green and remains lit. 5. All ports are enabled for normal operation and Ports are ready (see Section 1.3, LEDS). 4 ETHERNET CONNECTIONS All PoE front ports are configured as data through ports for all data wires. Be sure to use a standard Cat 5, 5E, or 6 cable including all 8 wires (4 pairs). 4.1 Data & Power Ports Using standard Cat 5, 5E, or 6 straight-through cable, connect cable leading to remote device to the corresponding Data & Power port. See Table 3 or Table 4 for Data & Power port pinout information. Table 3. 10/100BaseT & Power RJ-45 Pin-Outs PIN FUNCTION PIN FUNCTION 1 TX+ 2 TX– 3 RX+ 4 Positive V port 5 Positive V port 6 RX– 7 Negative V port 8 Negative V port Table 4. 1000BaseT & Power RJ-45 Pin-Outs PIN FUNCTION PIN FUNCTION 1 Bi-directional DA+ 2 Bi-directional DA– 3 Bi-directional DB+ 4 Bi-directional DC+ Positive V port 5 Bi-directional DC– Positive V port 6 Bi-directional DB– 7 Bi-directional DD+ Negative V port 8 Bi-directional DD– Negative V port Note: Be sure to connect each Data & Power port to the corresponding Data port. 4.2 Data Ports Using a standard Cat 5, 5E, or 6 cable, connect the cable leading from the Ethernet switch or hub to the Data port. See Table 5 or Table 6 for Data port pinout information. Page 8 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 Table 5. 10/100BaseT RJ-45 Pin-Outs PIN FUNCTION PIN FUNCTION 1 TX+ 2 TX– 3 RX+ 4 5 6 7 8 RX– Table 6. 1000BaseT RJ-45 Pin-Outs 5 PIN FUNCTION PIN FUNCTION 1 Bi-directional DA+ 2 Bi-directional DA– 3 Bi-directional DB+ 4 Bi-directional DC+ 5 Bi-directional DC– 6 Bi-directional DB– 7 Bi-directional DD+ 8 Bi-directional DD– COMMUNICATION/DAISY-CHAIN PORTS Com IN communications port on the front panel may be connected to a terminal or PC for local communications to the chassis. When more than one chassis are connected together all Com IN ports (chassis) after the first one become Com IN ports used to support the daisy-chain. 5.1 Com IN Port Figure 1 shows the Com IN port position on the chassis. Com IN port is a DB-9 receptacle style connector providing an RS-232 DCE interface for local communications. Pins two and three are used for data communications and pins one, six, and nine are used for chassis daisy chaining. When connecting a terminal to the COM IN port for local communications, use a DB9 straight through cable. When this port is connected to a terminal it is called a Console (CON) port. If the chassis is number two, three, four, or five in a daisy-chain this port is referred to as Com IN. This port does not support a modem. This port is used for local access to the chassis and is used to set the initial communication parameters. Shielded cable is recommended and the maximum cable length is 25 feet. A 1:1 cable is required to connect this port to the DTE com port of a PC. Pin out information is shown in Table 7 and Figure 6. Page 9 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 Table 7. Com IN (DCE) Pinouts PIN # FUNCTION PIN # FUNCTION 1 Daisy-Chain Id 0 – In 2 TXD 3 RXD 4 5 GND 6 Next Chassis Out 7 CTS 8 RTS 9 Daisy-Chain Id 1 – In 5 1 1 5 16235-A 9 6 6 9 10868-A 9-Pin Plug 9-Pin Receptacle Figure 6. 9-Pin D-Sub Connectors 5.2 Com OUT Port Figure 1 shows the Com OUT port position on the chassis. The CPU linecard provides an RS-232 DTE COM Out, daisy-chained communications port through a DB-9 plug style connector. Pins two and three are used for data communications and pins one, six, and nine are used for chassis daisy chaining. Shielded cable is recommended and the maximum cable length is 25 feet. Pin out information is shown in Table 8 and Figure 6. Table 8. Com OUT (DTE) Pinouts PIN # FUNCTION 1 Daisy-Chain Id 0 – Out 2 3 TXD 4 5 GND 6 7 9 PIN # FUNCTION RXD Next Chassis In 8 Daisy-Chain Id 1 – Out When configured with a CPU, the PoE chassis may be daisy-chained to four additional chassis using the Com IN and Com OUT port located on the chassis front. This allows a single IP address to be assigned to a total of five PoE chassis for network and SNMP access. Five chassis daisy-chained together are shown in Figure 7. Page 10 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 COM IN CPU SNMP LINECARD PRESENT COM OUT COM IN CPU SNMP LINECARD NOT PRESENT COM OUT COM IN CPU SNMP LINECARD NOT PRESENT COM OUT COM IN CPU SNMP LINECARD NOT PRESENT COM OUT COM IN CPU SNMP LINECARD NOT PRESENT 19632-A Figure 7. Daisy-Chain Configuration 6 MAINTENANCE Maintenance requirements for the ADC Power over Ethernet Midspan Controller covered in this manual are minimal, consisting merely of periodic cleaning. The outside of the chassis and components should be cleaned during routine office equipment maintenance. Care must be taken to prevent dust and dirt from getting into any of the Ethernet jacks. For any repairs, contact ADC field service at the telephone numbers listed in the Section 12, Customer Information and Assistance, of this manual. Page 11 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 7 SPECIFICATIONS Specifications for the chassis are listed in Table 9. Table 9. Power over Ethernet Chassis Specifications PARAMETER SPECIFICATION REMARKS Power Voltage 100 – 240 VAC nominal Input Current 3.75 A maximum at 120 VAC 1.85 A maximum at 240 VAC Fuse Size Fused per local practices and codes. Power Supply 8-Port 200 Watt 16- and 24-Port 400 Watt Environmental Operating Conditions +32°F to +104°F (0°C to +40°C) 5% to 85% RH Mechanical Dimensions D x W x H 15.97 in (40.6 cm) D 19.0 in (46.5 cm) W 1.73 in (4.4 cm) H See Figure 8. * Weight 13.34 lb. (6.1 kg.) with one power supply 16.6 lb. (7.5 kg.) with two power supplies Chassis without CPU Chassis without CPU * - Shown with mounting brackets installed for 19-inch rack mounting. Page 12 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 14.82 IN. (37.6 CM) 15.96 IN. (40.5 CM) 19.0 IN. (48.3 CM) 1.25 IN. (3.2 CM) 18.28 IN. (46.3 CM) 1.73 IN. (4.4 CM) 20162-B 1.0 IN. (2.5 CM) Figure 8. Chassis Dimensions 8 REPLACING POWER SUPPLY Warning: To prevent electrical shock, verify that input power source is off (switch in the OFF position or AC plug removed). In the event of a fan or power supply failure, the modular power supply may be removed from chassis for replacement. If chassis is equipped with redundant power supplies a failed power supply may be removed while PoE is in operation. If chassis is equipped with redundant power supplies, data transmissions through the PoE are not interrupted when the failed power supply is removed. Page 13 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 Replace power supply module as follows: 1. Move power switch to the OFF position. 2. Remove power cord. 3. Loosen the thumb screws on each end of the power supply module. See Figure 9. 4. Remove power supply module by pulling it straight out of the PoE chassis. 5. Carefully slide power supply module into the slot until the board edge connector mates completely with the power supply connector. If excessive resistance is felt, withdraw the module and check for obstructions and proper alignment. 20163-C POWER SUPPLY THUMB SCREW (2 PLACES) Figure 9. Power Supply Module Thumb Screws 6. Secure power supply module in place by tightening the retaining screws on the module. Be sure screws are properly threaded before tightening. 7. Insert plug into the receptacle on the rear of the power supply module. 8. Move power switch to the ON position. 9 OPERATION These instructions describe the user interface found on the COM IN serial port of the ADC PoE Midspan Controller with legacy support. Interface provides status information for all Ethernet ports and power supplies as well as alerts for any status changes. Legacy PoE equipment may require power pins to be reversed (crossed) to provide power over the span. ADC PoE Midspan Controller may be set to support IEEE-802.3af or legacy equipment through one or more ports. Page 14 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 9.1 Start Up The on-board PoE micro-controller features a minimum command-line interface over the serial DB-9 receptacle COM IN port. Chassis status may be viewed by connecting a computer or terminal to this port. Connect a VT-100-compatible host computer to the COM IN port. Set up communications with the chassis. A communications software program or terminal is required to communicate with PoE chassis. Use a DB9 straight through cable to connect the COM IN port to the host terminal or computer. Use a straight through cable, when connecting a terminal to the COM IN port for local communications. Communication parameters must be set to 9600 baud, 8 Data bits, 1 stop bits, no parity and no flow control. LED's indicate port and power status, see Section 1.3, LEDS for descriptions. Upon boot-up, the unit briefly sets all Ethernet port LEDs to yellow then green and displays the following over the COM IN port (See Figure 10.): Type '?' ‘TL’ 'Xnn' to to to to show status show usage test LED’s toggle power pins for Ethernet port n (01-24) Midspan PoE Injector Version 1.0.0 Build 1 (with Legacy) Boot loader v1.0.0 Build 1 Copyright (c)2004-2005 ADC PoE configuration found: #2 Cat#: POE-LEGACY P/S#1:A/C OK PALS400-2482--P/S#2:A/C OK PALS400-2482--- P/N:PROTOTYPE S/N:0002 Watts:400 S/N:LY1160 Rev:13 Watts:400 S/N:000636 Rev:ABO Ports: 1 2 3 4 5 6 7 8 Crossed: Class/Disabled/Legacy: L Powered: P Ports ON: 03/24 1 1 1 1 1 1 1 9 0 1 2 3 4 5 6 X Power consumption: 0008W 1 1 1 2 2 2 2 2 7 8 9 0 1 2 3 4 L P 2 P Up 0:07:54:10 Figure 10. Unit Status The first block of information briefly describes the user commands available over the COM IN port: • Type to refresh the midspan unit status, • Typing a question mark ‘?’ displays Help Menu, • The ‘TL’ command repeats the LEDs test performed upon boot-up (all port LEDs yellow then green) to verify all port LEDs, • The ‘Xnn’ command allows crossing of the power-over-Ethernet power pins of a port to support legacy equipment requiring this setting. The second block of information shows the midspan firmware version. The third block (starting at ‘Cat#’) shows: • The midspan inventory information (catalog number, part number and serial number), • For each power supply, its status and inventory information. Page 15 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 The fourth block of information shows PoE port status: • Port numbers from 1 to 24, • Crossover of the power-over-Ethernet power pins indicated by an ‘X’ for a port, • Port status: ‘D’ for disable, blank when no device is attached to the port, ‘L’ for a detected legacy PoE device at the port, the 802.3af power classification number (from 0 to 3) for 802.3af-compliant PoE devices detected at a port, or one of the following lowercase characters for error conditions causing the port to be left unpowered: ‘-’: non-PoE device attached, ‘b’: power budget exceeded, ‘e’: external voltage source applied to the PoE device, ‘f’: succession of overloads and underloads detected, ‘g’: discharged load detected, ‘h’: hardware fault, ‘o’: overload, ‘s’: short condition, ‘t’: over-temperature, ‘u’: underload, ‘?’ or ‘!’: unknown state for the port. • Power status: a ‘P’ is displayed for powered ports (with a corresponding green LED), while an asterisk ‘*’ is shown for ports with one of the error conditions listed above. The last block of information shows the number of ports powered, the ports wattage consumption, and midspan unit uptime. On the midspan unit status example shown Figure 10: • • • • • • Both power supplies are inserted and functioning correctly, PoE port 12 has its power pins crossed over, Ports 2 and 19 detected and are powering legacy PoE devices, Port 24 detected an 802.3af class 2 device and is powering it, 3 out of 24 ports are powered and consume 8 watts, The midspan unit has been up 7 hours, 54 minutes and 10 seconds. Power pins for port 12 were crossed with an ‘X12’ command issued over the COM IN port. The ‘Xnn’ command (where nn is the port number from 01 to 24) toggles the crossover setting of the PoE port power pins. Hence entering this command twice in a row for a particular port will place the power pins back to the original setting. Every time the crossover setting is changed for a port, it is saved in the permanent PoE configuration of the midspan unit and does not need to be entered again if the chassis is powered down. Page 16 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 The ADC PoE midspan unit also sends alerts over the COM IN port upon PoE port status changes, such as: - Port 24: ON [802.3af] - Port 02: ON [legacy] - Port 13: OFF 802.3af compliant device found and powered on port 24, Legacy PoE device found and powered on port 2, PoE device removed from port 13. The ADC PoE midspan unit sends alerts over the COM IN port upon power supplies status changes, such as: - Unit: ** Power supply #1 A/C FAILURE !! - Unit: ** Power supply #1 A/C restored A/C feed failure for supply #1, A/C feed restored for supply #1. The on-board PoE micro-controller controls and monitors only the local unit. It does not provide control or status for other midspan units that may be daisy-chained to it. In addition: • In a daisy-chain environment, only the first unit will feature this command-line (other units down in the daisy-chain have the command-line disabled). Use the optional CPU card in a daisy-chain environment to provide status and control for all daisy-chained units. • When optional CPU card is plugged in, it takes over the serial COM IN port from the on-board micro-controller. The command line interface is disabled. Refer to the CPU command manual. 10 TROUBLESHOOTING This section helps you locate problems related to the PoE setup and functionality. Troubleshooting provides a problem and possible resolutions to assist in locating minor operating problems. If the provided resolutions do not solve your problem, call ADC for further assistance. If you encounter problems, make sure: • • • • Power is applied to the chassis. An input Ethernet cable is connected to the Data port. An output Ethernet cable is connected to the Data & Power port. The input and output cable pairs are attached to corresponding ports. Table 10. Troubleshooting PROBLEM RESOLUTION PoE is plugged into a main AC outlet, but does not power up. Verify that a correct and functional AC power cord is used, including a good solid ground connection. Verify that AC outlet is supplying power (test with another device) and that voltage is between 100VAC and 240VAC (50Hz/60Hz). Reconnect PoE to AC outlet and verify the LEDs power up sequence. See Section 1.3, LEDS. PoE is plugged in and running, but fan is not working. Verify all fan openings in chassis are clear of any obstructions. If fan is not working, there may be an internal power supply fault. Replace power supply. Page 17 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 Table 10. Troubleshooting, continued PROBLEM RESOLUTION PoE operates, but AC LED is off. If internal fan is working, there is a possible internal circuitry fault. If fans are not working, there may be an internal power supply fault. Replace power supply. PoE has powered up and ON LED is red. Check self-test sequence. If LEDs light in the correct sequence, PoE is fully operational. If problem remains following self-test sequence, PoE self-test detected an internal fault. Contact ADC. Power supply is operating and rear LED is amber. Power supply has exceeded the maximum operating temperature and will shut down. • Verify all fan openings in chassis are clear of any obstructions. • If fan is not working, there may be an internal power supply fault. • If internal fan is working (that is, air flows in to the chassis or can be heard), there is a possible internal circuitry fault. Replace power supply. Port LED on one port is not lit and the corresponding remote device does not operate. PoE did not detect a connected remote device, therefore port is not providing power. Verify that: • Remote device is Power Over LAN enabled. • Verify that you are using a standard UTP Category 5, 5E, or 6 cable, including all 8 wires (4 pairs). • If an external splitter is in use, replace it with a new splitter. Discard faulty splitter. • Remote device is connected to the Data & Power port (upper RJ-45 connector). In addition, try to: • Re-connect the same remote device to a different port on the same unit. If it works, there is probably a faulty port or RJ-45 connection. • Bypass the long twisted pair cable and move remote device closer to PoE and connect to one of the ports using a short cable. If this works, most likely there is a faulty connection or short on the long cable, or a bad RJ-45 connection in the line. Try powering it up again and verify a correct power-up LED sequence. Page 18 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 Table 10. Troubleshooting, continued PROBLEM RESOLUTION Remote device operates, but there is no data link. Verify that: • Port LED on PoE front panel is lit continuously. • Data and Data & Power ports correspond. • Verify that you are using a standard UTP Category 5, 5E, or 6 cable, including all 8 wires (4 pairs), and is 100m or less in length between switch and remote device. • PoE is connected to a switch or hub with a good RJ-45 patch cord connection. In addition, try to: • Bypass the long twisted pair cable and move remote device closer to PoE and connect to one of the ports using a short cable. If this works, most likely there is a faulty connection or short on the long cable, or a bad RJ-45 connection along the line. • Connect a different remote device to the port. If this works and link is established, there is probably a faulty data link in the remote device. • Re-connect remote device to a different Data & Power port and remember to move the Data port of the switch or hub accordingly. If this works, there is probably a faulty Data & Power or Data port in the PoE or a bad RJ-45 connection. One of the ports is powering a remote device without turning Port LED on. Re-connect remote device to a different Data & Power port. If the LED turns on, there is a fault in the previous output port (probably a faulty LED). Is it safe to keep PoE running while the rear LED is Amber? Yes, this condition is safe for a short period of time. 11 SNMP – WEB MANAGEMENT Use of optional CPU linecard provides a 10/100Base-T Ethernet connection through a RJ-45 jack. Page 19 © 2006, ADC Telecommunications, Inc. ADCP-92-055 • Issue 6 • January 2006 12 CUSTOMER INFORMATION AND ASSISTANCE PHONE: EUROPE Sales Administration: +32-2-712-65 00 Technical Assistance: +32-2-712-65 42 EUROPEAN TOLL FREE NUMBERS Germany: 0180 2232923 UK: 0800 960236 Spain: 900 983291 France: 0800 914032 Italy: 0800 782374 U.S.A. OR CANADA Sales: 1-800-366-3891 Extension 73000 Technical Assistance: 1-800-366-3891 Connectivity Extension 73475 Wireless Extension 73476 ASIA/PACIFIC Sales Administration: +65-6294-9948 Technical Assistance: +65-6393-0739 ELSEWHERE Sales Administration: +1-952-938-8080 Technical Assistance: +1-952-917-3475 WRITE: ADC TELECOMMUNICATIONS, INC PO BOX 1101, MINNEAPOLIS, MN 55440-1101, USA ADC TELECOMMUNICATIONS (S'PORE) PTE. LTD. 100 BEACH ROAD, #18-01, SHAW TOWERS. SINGAPORE 189702. ADC EUROPEAN CUSTOMER SERVICE, INC BELGICASTRAAT 2, 1930 ZAVENTEM, BELGIUM PRODUCT INFORMATION AND TECHNICAL ASSISTANCE: [email protected] [email protected] [email protected] 13944-M [email protected] Contents herein are current as of the date of publication. ADC reserves the right to change the contents without prior notice. In no event shall ADC be liable for any damages resulting from loss of data, loss of use, or loss of profits and ADC further disclaims any and all liability for indirect, incidental, special, consequential or other similar damages. This disclaimer of liability applies to all products, publications and services during and after the warranty period. This publication may be verified at any time by contacting ADC's Technical Assistance Center. © 2006, ADC Telecommunications, Inc. All Rights Reserved Printed in U.S.A. Page 20