Mini Wall mount product specifications
Document details Release date document: January 2015 Document version: 1.0 Document status: Final version Document number: D010.072014.1.0
Product Specifications
Notes regarding this document No part of this document including the software described in it may be reproduced, transmitted, transcribed, stored in a database system or translated without the express written permission of SpeeQ. Documentation kept by the enduser for backup purposes is excluded from the above mentioned. • All products and corporate names mentioned in this document may be registered trademarks or copyrights of their respective companies. They are used here for indicative purposes only. • The information contained in this document has been carefully checked for accuracy, however no guarantee is given with respect to the correctness. SpeeQ accepts no responsibility or liability for any errors or inaccuracies that may appear in this document or the products and/or software described in it. • Specifications and information contained in this document are subject to change at any time without notice.
D010.072014.1.0
Page 2 of 11
Product Specifications
Contents 1. General description .........................................................................................................................................................4 2. Specifications and panel information ..............................................................................................................................6 3. System specifications ....................................................................................................................................................10
D010.072014.1.0
Page 3 of 11
Product Specifications
1. General description About EvaQ EvaQ is a certified voice alarm evacuation system. A typical EvaQ Mini system consists of 4 different components. The Wall mount control unit with a build in power supply, a control panel, end of line units or isolators and loudspeakers are the key elements for a functional EvaQ Mini system.
EvaQ Mini wall mount cabinet The EvaQ mini wall mount cabinet contains all the intelligence needed to drive the system. It is the technological hub of the EvaQ Mini system setup and contains the primary power supply. Audio sources, control panels and smart interfaces can be linked directly to the wall mount cabinet. Smart electronics in the control unit process the audio signals, offer a digital memory for predefined texts and alarm audio signals. Every single wall mount cabinet contains one or more amplifier modules to feed amplified signals to the connected speakers. A backup amplifier is included in each system unit. The unit drives 4 or 6 zones and can either handle up to six loops or up to twelve feeder lines. By linking more wall units to each other a scalable and decentralized system setup is established. This helps to reduce the amount of loudspeaker cable within large sites. The Wall mount unit can be equipped with or without a build-in control panel and work with prioritized additional control panels to create maximum flexibility to control larger sites.
D010.072014.1.0
Page 4 of 11
Product Specifications
Wall mount system configuration A basic wall mount system starts with 600W/100Vac output power that can be divided over 4 to 6 loudspeaker zones (groups) depending on the chosen configuration. Each amplifier in the EvaQ system is capable of generating an output power of 5 – 600Watt. By placing additional amplifiers more amplification power is made available to the loudspeaker zones. The primary power supply in the single cabinet is capable of driving 1200W of amplification power. By application of a power extension cabinet, an additional power supply is available to provide the single cabinet system with an additional 1200W output power. The EvaQ wall mount concept works with a simple 3 step power scale up:
single cabinet EvaQ Wall mount System configuration
Single cabinet with power expansion cabinet
basic
step 1
step 2
step 3
Available zones
6
6
4
6
Applied number of amplifiers 5-600W
1
2
4
6
Standard backup amplifier 5-600W
1
1
1
1
Primary power supply 1200W
1
1
Secondary power supply 1200W Available maximum output power
600W
1200W
1
1
1
1
2400W
2400W
Next to the power scale up, the system can be set into 3 type of field cable configurations using a matrix card. Each system needs to have one matrix card to be fully operational: • • •
A matrix card for loop configuration, up to 6 loops per cabinet (and use of isolators) A matrix card for feeder line configuration, up to 12 lines per cabinet (and use of end of line units) A matrix card for A/B line configuration, up to 12 outputs (use of A/B switch and A/B loudspeakers)
Wall mount control panel For Wall mount units with a build-in control panel all paging and evacuations can be managed from the wall unit itself. To access the control panel simply use the key to open the first cabinet door. The control buttons on the panel provide flexibility in control. They can be configured to control single zone outputs or groups of zone outputs for larger building parts. Text labels can be added to specify the detailed function of each button. All control activities and system statuses are visualized by power efficient LED indications on the panel.
D010.072014.1.0
Page 5 of 11
Product Specifications
2. Specifications and panel information
2 levels of access: user level and authorized technician level
Front view of a single cabinet
Air flow exit
detachable mounting strips
Cable entry
Back side view of a single cabinet
D010.072014.1.0
Page 6 of 11
Product Specifications
Detailed view of the control panel on the cabinet
Front panel system indications Control status
Normal Active state
Remark
Operation Evacuation System status
Green
normal operation evacuation active general error (this unit or other units, control panel, canbus) communication error microcontroller hips on motherboard microphone error control panel error error fire panel interface fan error, control panel power error, fuse error backup amplifier error battery error 230Vac error, power supply error amplifier active evacuation active memory indication: evacuation by fire panel loop interruption / ground error end of line unit amplifier error error on other connected system(s) or can bus fault ground error loop cable / cable to end of line unit
Red *3 Yellow *1*4
Microcontroller
Yellow *1*4
Mic. Panel operation
Yellow *1 Yellow *2 Yellow *1 Yellow *1 Yellow *1 Yellow *1 Yellow *2 Green *2 Red Red *2 Yellow *1 Yellow *2 Yellow Yellow *1
Fire panel status Fuse Backup amplifier Power Amplifier 1 - 6
Loop status (amplifier 1 - 8) Error sub system Ground
D010.072014.1.0
Page 7 of 11
Product Specifications
Front panel zone selection and operation indications Control status
Normal Active state
Remark
Operation (small led)
Green
zone selection is in normal operation Error(s) in internal canbus loop General error (on this control panel, External canbus, or other units) Announcement possible in selected zones one or more zones occupied by other panel (overruling of an announcement from another control panel only possible for a panel that is configured as “ master”) Active evacuation initiated this by other EvaQ System or EvaQ panel Zone/function selection active Zone selection active Active evacuation in selected zone
Control error (small led)
Green*1/2/3 Yellow *4
Free / occupied (small led)
Red Red *4
General Alarm (small led)
Red
Configurable Button P1-4 Configurable Button 1-8
blue blue Red
*1: led blinking frequency = 0,25 Hz (once per four seconds) *2: led blinking frequency = 0,50 Hz (once per two seconds) *3: led blinking frequency = 1 Hz (once per second) *4: if both leds are active and the rest are off: system is in watchdog mode; the system is overloaded or overheated
Control Buttons All buttons are activated via single touch, only otherwise when mentioned Start Evacuation Manual evacuation start (in selected zones). Stop Evacuation Stop of an initiated evacuation with “start evacuation” button. Buzzer reset In case of a system error this button resets buzzer signal for 10 minutes Reset zone selection Reset of manual (pre)selected zones Panel lamp test Activation of all panel led’s for functional inspection, as long as button pressed Announce Activation of an announcement in selected zones, via microphone, as long as button pressed Sel. all zones Simultaneous selection of all panel zones at once P1-4 Activation or selection of function under button P1 to P4 Zone 01 – 08 Selection of zone 1 to 8 (the 6 amplified outputs can be programmed in individual and/or combined groups) Reset loop fault In case of a line fault in a loop system this button resets buzzer signal for 10 minutes Front panel microphone Push to Talk (PTT) button control for making announcements in selected zones
D010.072014.1.0
Page 8 of 11
Product Specifications
Illustration of a system configuration with a single cabinet and an added expansion unit
Duo cabinet dimensions: 700 mm (Width) x 1440 mm (Height) x 35 mm (Depth)
D010.072014.1.0
Page 9 of 11
Product Specifications
3. System specifications General
- Dimensions single wall cabinet (H x W x D) : 720 x 700 x 350 mm - Factory specified ambient temperature for normal operation: 10 - 25°C - Weight: Housing 43 kg without batteries, 65 kg max. with batteries and amplifiers - Number of battery positions in cabinet: 4 x 24Ah/ 4 x 38Ah - Maximum power consumption basic wall mount version: 230VAc / 1300W - Color: RAL9001 - Amplifiers: (6 maximum) + 1 Back Up - Amplifier power per amplifier: 10-600 Watts - Number of zones: 6 (standard configuration) - Number of loops per unit: 6 max. (Loop system configuration) - number of lines per unit: 12 max. (Feeder line configuration) - Number of line in A/B configuration: 12max. (A/B configuration) - Maximum amplifier power per loop: 600 Watts rms - Maximum amplifier power per line (end of line): 300 Watts rms - Maximum amplifier power in Normal operation : 600-2400 Watts rms - Class D amplifiers - Protection: Short circuit, DC failure, overload, thermal overload. - Temperature monitoring - THD : 0.01 % in Normal mode - THD : 0.69 % in Battery mode - DSP Sample rate 24bit, 48kHz. - DA/AD conversion 24bit Delta Sigma converters - SNR: >100dB - Sound Chip Evacuation messages: 44.1kHz / mono 16bit - 32 Mb message memory (up to 16 minutes of audio storage)
Interfaces
- Network interface type (x3) : Canbus IS011898 - Maximum number connected system cabinets : 32 - interconnection between units: UTP (standard) or Fiber (converters needed) - protection - USB 3.0 programming input on system and power supply (proprietary programming tool)
Inputs audio
- 6 x 0 dB(V) (line input, nominal level - Maximum level : 2 Vtt (peak, per line input) - Impedance (electric balanced) : 9k Ω
Outputs
- 8 x Relay: N.O./N.C. including Watchdog max. 24Vdc/500mA
Inputs
- 8 x Guarded input max. 5Vdc (for connection to fire panel) - 8 x Digital inputs 8-30Vdc <2,5mA
Power Expansion
- Dimensions power expansion wall cabinet (H x W x D) : 720 x 700 x 350 mm - Weight: 43 kg without batteries, 65 kg max. with batteries. - maximum power consumption: 230Vac / 1300W - Additional amplifier output power 1200W max. (available by application of additional amplifiers in the single wall cabinet)
Certification
- EN54-4, EN54-16 certificate scheduled Q1 2015 (certification is pending).
D010.072014.1.0
Page 10 of 11
Product Specifications
System parts and articles EvaQ Mini Wall Mount Article number
Article description
Article information
1250-1
Wall mount EvaQ 600W, 6 zone
Wall mount unit 1/6, control panel, 1.2KW PSU included
1250-2
Wall mount EvaQ 1200W, 6 zone
Wall mount unit 2/6, control panel, 1.2KW PSU included
1250-4
Wall mount EvaQ 2400W, 4 zone
1250-6
Wall mount EvaQ 2400W, 6 zone
1255-1
Wall mount EvaQ 600W, 6 zone without panel
Wall mount unit 4/4, control panel, 1.2KW PSU (Note: 1,2KW PSU power extension unit needs to be added) Wall mount unit 6/6, control panel, 1.2KW PSU + 1,2KW PSU power extension unit needs to be added Wall mount unit 1/6, 1.2KW PSU included
1255-2 1255-4S
Wall mount EvaQ 1200W, 6 zone without panel Wall mount EvaQ 2400W, 4 zone without panel
1255-6S
Wall mount EvaQ 2400W, 6 zone without panel
Wall mount unit 2/6, 1.2KW PSU included Wall mount unit 4/4, 1.2KW PSU + 1,2KW PSU power extension unit included Wall mount unit 6/6, 1.2KW PSU + 1,2KW PSU power extension unit included
Other system parts 2250-1
Power extension Unit Wall mount 1200 Watt
Wall mount unit, 1.2KW PSU, closed door for use in combination with a wall mount EvaQ system cabinet
1901-1
Loop isolator matrix card for system
Loop isolator Matrix Card ( only in combination with wall mount system)
1902-1
End of line matrix card for system
End of Line module Matrix Card ( only in combination with wall mount system)
1903-1
A/B line matrix card for system
A/B switch Card ( only in combination with wall mount system and A/B switch)
5504-1 5506-1 5509-1
A/B Switch 3 zone (6 Outputs) A/B Switch 6 zone (12 Outputs) A/B Switch housing
8651-1 8660-1
Connector Set System (incl. keys for front and side) USB 3.0 Programmer for EvaQ mini Wall mount unit
D010.072014.1.0
Page 11 of 11