Preview only show first 10 pages with watermark. For full document please download

Mirror Optic Pir Installation Instructions

   EMBED


Share

Transcript

AP669 Ceiling Mount Detector Installation Instructions 9 1 8 2 7 1 3 6 1 8 2 7 3 6 4 1   2   3   4   5   6   7   8   9  10 3 O N 1 2 O N 1 2 3 4 4 1 2 3 4 5 6 7 8 9 10 ñ + NC C NO ALARM TAMPER 5 OPERATION: 7 ñ15V 3 3 7 8 9 1 2 in. 6 4 5 5 4 5 2 CURRENT: 6 mA NOM. ALARM: 11 mA MAX MADE IN THE NETHERLANDS 9 8 4 6 4 EV669 SPARE 7 2 3 7 3 5 8 2 1 6 An arrow inside the mounting plate & sensor module indicates the always active direction. 7 9 Shaded area shunted when switch 3 is ìONî position. 5 30' 30' Figure 2 Figure 1 Mounting Instructions Selecting a Mounting location • Lift off mounting plate (1) as shown in Figure 1. Fasten the mounting plate to the ceiling in the required position using mounting holes (2). Install the detector so that the expected movement of an intruder will be across the fields of view. This is the direction best suited for PIR detectors. The detection pattern can be adjusted by up to ±15° (max 30°) by rotation of the mounting plate prior to tightening the screws. • Strip outer jacket approximately 2 inches (50mm) and pull it through the cable entry hole (3) and strain relief. • Wire the detector and select the appropriate processing options as shown in Figure 3 and replace the sensor module (6). • To mount the sensor module to the mounting plate use the screw (7) which is placed for transport in the mounting plate. The curtain directions 1-9 clockwise (8), are indicated in the mounting plate. (Curtain number 5 is the center curtain.) Avoid possible false alarm sources such as: • Direct sunlight onto the detector. • Heat/cold sources in a field of view (heaters, air conditioning, radiators, etc.). • Moving objects in the field of view (fans, pets, etc.). Increasing mounting heights beyond the specified range will reduce sensitivity. Connection and Programming 1 2 ñ + Switch 1: Programming the LED ON OFF LED enabled LED disabled 5 6 7 8 NC C NO ALARM TAMPER 9 10 SPARE ON 1 2 3 Enables Bi-curtain processing designed for harsh environment. Provides the standard 4D processing. Switch 3: Programming the detection pattern ON OFF 4 Figure 3 Switch 2: Programming the processing ON OFF 3 Switch Description On Off 1 LED enable LED on LED off 2 Processing 3 Detection pattern Provides a 180° field of view for special applications. Gives the normal 360° field of view. Note: An arrow in the mounting plate (4) (see Figure 1 and Figure 2) and inside the sensor module shows the always active coverage pattern. The coverage pattern opposite to the arrow can be disabled by setting switch 3 in the “ON” position. Access to the Mirror Inside the Sensor Module Masking Coverage Patterns 360° Field of View 1 & 9 Mounting Height 8—16 ft 60° 1.8 ft 12 3 456 7 89 2 & 8 20° 1.8 ft 3 & 7 Selecting the Coverage Patterns For example, see Figure 4 for mirror curtain coverage pattern corresponding to curtain 4 and 8 masked. 180° 5.4 ft This access is only required when masking individual curtains. Undo the screw (5) and open the sensor module (6) (see Figure 1). The two mirrors are accessible now. Mask the appropriate mirror curtains with the adhesive labels provided and reassemble the sensor module. Bi-curtain Standard-4D 48° 1.8 ft 1 9 8 1.8 ft 2 7 3 6 5 48° 4 & 6 90° 5 4 30' shaded area is shunted when switch 3 is ON Figure 4 Mounting Height Application Note When increased mounting heights are used outside the specified mounting height range of 8 - 16 ft (2.4 - 4.8m), sensitivity will be reduced. Specifications Input power ............................................................... 12 or 24V (7–28V) Alarm time ............................................................................ min 2.5 sec. Peak to peak ripple ...................................................... 2V max. (at 12V) Tamper output ................................................................. 100 mA at 28 V Current consumption Temperature limit ............................... 0°F to +131°F (–18°C to +55°C) Normal operation .................................................... 11 mA (at 12V) Relative humidity .................................................................... max. 93% Alarm ............................................................. 13 mA max. (at 12V) Size ................................. 5.43 in. dia. x 2.68 in. (138mm dia. x 68 mm) Specified mounting height ..................................... 8 – 16 ft (2.4 - 4.8m) Weight ................................................................................... 4.25 ounces Target speed range ............................................ min. 0.9 – max. 12.0 ft/s Number of curtains .............................................................................. 18 Alarm output ....................................................... 50 mA at 28 V Form C Max. detection range ................. 60 ft (18m) diameter, 30 ft (9m) radius Listings ..................................................................................... C-UL US 33Ω g GE Security GE Security 12345 SW Leveton Drive Tualatin, OR 97062 503-692-4052 USA & Canada: 800-547-2556 Tech Support 800-648-7424 FaxBack: 800-483-2495 www.ge-security.com 14012 Rev C 03/04