Transcript
MISA SERIES Premium Range Modular Cool or Freezer Room Italian designed, premium polyurethane modular cool storage management. Internal & external rounded corners for easy cleaning and food sanitation
Quick and easy assembly Ideal for high ambient temperatures Suitable for almost any location Adaptable to changing circumstances Options to suit
MISA integral Freeblock condensing unit locks into place in a matter of minutes
MISA high density MVS patented polyurethane panel system for better insulation
KLC-model
MISA insulated and reinforced galvanised MISA Drop-in unit
capable of a 4000 kg/m3 static load durability
Warranty 2 year protection* PSF0023
*excludes installation faults
Internal safety door opening and manual
MISA Series Modular Cool or Freezer Room System Freeblock
Power
Dimensions External W x D x H Internal W x D x H
3.07 3.68 4.06 4.87
FB 3G/6 FB 3G/6 FB 3G/6 FB 3G/6
1PH 1PH 1PH 1PH
1350 × 1350 × 2150 1350 × 1350 × 2550 1350 × 1750 × 2150 1350 × 1750 × 2550
1230 × 1230 × 2030 1230 × 1230 × 2430 1230 × 1630 × 2030 1230 × 1630 × 2430
09C 11C 13C 15C
5.39 6.45 6.71 8.04
FB 7G/6 FB 7G/6 FB 13G/6 FB 13G/6
1PH 1PH 1PH 1PH
1750 × 1750 × 2150 1750 × 1750 × 2550 1750 × 2150 × 2150 1750 × 2150 × 2550
1630 × 1630 × 2030 1630 × 1630 × 2430 1630 × 2030 × 2030 1630 × 2030 × 2430
KLC 3C F 2M-6 KLC 3C F 2.4M-6 KLC 4C F 2M-6 KLC 4C F 2.4M-6
17C 19C 21C 23C
8.37 10.01 10.05 11.99
FB 13G/6 FB 13G/6 FB 16G/6 FB 16G/6
1PH 1PH 1PH 1PH
2150 × 2150 × 2150 2150 × 2150 × 2550 2630 × 2150 × 2150 2630 × 2150 × 2550
2030 × 2030 × 2030 2030 × 2030 × 2430 2430 × 2030 × 2030 2430 × 2030 × 2430
KLC 4D F 2M-6 KLC 4D F 2.4M-6 KLC 5D F 2M-6 KLC 5D F 2.4M-6
25C 27C 29C 31C
11.99 14.34 13.95 16.71
FB 16G/6 FB 20G/6 FB 20G/6 FB 20G/6
1PH 3PH 3PH 3PH
2550 × 2550 × 2150 2550 × 2550 × 2550 2950 × 2550 × 2150 2950 × 2550 × 2550
2430 × 2430 × 2030 2430 × 2430 × 2430 2830 × 2430 × 2030 2830 × 2430 × 2430
KLC 5E F 2M-6 KLC 5E F 2.4M-6 KLC 6E F 2M-6 KLC 6E F 2.4M-6
33C 35C 37C 39C
16.25 19.46 18.56 22.21
FB 20G/6 FB 26G/6 FB 26G/6 FB 26G/6
3PH 3PH 3PH 3PH
2950 × 2950 × 2150 2950 × 2950 × 2550 3350 × 2950 × 2150 3350 × 2950 × 2550
2830 × 2830 × 2030 2830 × 2830 × 2430 3230 × 2830 × 2030 3230 × 2830 × 2430
SKOPE Reference
CBM2 Internal
KLC 1A F 2M-6 KLC 1A F 2.4M-6 KLC 2A F 2M-6 KLC 2A F 2.4M-6
01C 03C 05C 07C
KLC 2B F 2M-6 KLC 2B F 2.4M-6 KLC 3B F 2M-6 KLC 3B F 2.4M-6
MODEL
• • •
Floor
Utilise an existing insulated concrete oor by using a high density ‘U’ channel for and sealing walls (cool rooms only) MISA insulated and reinforced galvanised steel roll in oor system with anti-slip coating. It is recommended that all single phase units are to be on a 20A circuit.
Freezer Rooms
• • •
MODEL
SKOPE Reference
CBM2 Internal
KLC 1A N 2M KLC 1A N 2.4M KLC 2A N 2M KLC 2A N 2.4M
101F 102F 103F 104F
KLC 2B N 2M KLC 2B N 2.4M KLC 3B N 2M KLC 3B N 2.4M
Floor
Dimensions External W x D x H Internal W x D x H
Freeblock
Power
3.07 3.68 4.06 4.87
FB 6N/10 FB 6N/10 FB 6N/10 FB 6N/10
1PH 1PH 1PH 1PH
1430 × 1430 × 2230 1430 × 1430 × 2630 1430 × 1830 × 2230 1430 × 1830 × 2630
1230 × 1230 × 2030 1230 × 1230 × 2430 1230 × 1630 × 2030 1230 × 1630 × 2430
105F 106F 107F 108F
5.39 6.45 6.71 8.04
FB 6N/10 FB 13N/10 FB 13N/10 FB 13N/10
1PH 1PH 1PH 1PH
1830 × 1830 × 2230 1830 × 1830 × 2630 1830 × 2230 × 2230 1830 × 2230 × 2630
1630 × 1630 × 2030 1630 × 1630 × 2430 1630 × 2030 × 2030 1630 × 2030 × 2430
KLC 3C N 2M KLC 3C N 2.4M KLC 4C N 2M KLC 4C N 2.4M
109F 110F 111F 112F
8.37 10.01 10.05 11.99
FB 13N/10 FB 13N/10 FB 20N/10 FB 20N/10
1PH 1PH 3PH 3PH
2230 × 2230 × 2230 2230 × 2230 × 2630 2630 × 2230 × 2230 2630 × 2230 × 2630
2030 × 2030 × 2030 2030 × 2030 × 2430 2430 × 2030 × 2030 2430 × 2030 × 2430
KLC 4D N 2M KLC 4D N 2.4M KLC 5D N 2M KLC 5D N 2.4M
113F 114F 115F 116F
11.99 14.34 13.95 16.71
FB 20N/10 FB 20N/10 FB 20N/10 FB 20N/10
3PH 3PH 3PH 3PH
2630 × 2630 × 2230 2630 × 2630 × 2630 3030 × 2630 × 2230 3030 × 2630 × 2630
2430 × 2430 × 2030 2430 × 2430 × 2430 2830 × 2430 × 2030 2830 × 2430 × 2430
KLC 5E N 2M KLC 5E N 2.4M KLC 6E N 2M KLC 6E N 2.4M
117F 118F 119F 120F
16.25 19.46 18.56 22.21
FB 20N/10 FB 28N/10 FB 28N/10 FB 28N/10
3PH 3PH 3PH 3PH
3030 × 3030 × 2230 3030 × 3030 × 2630 3430 × 3030 × 2230 3430 × 3030 × 2630
2830 × 2830 × 2030 2830 × 2830 × 2430 3230 × 2830 × 2030 3230 × 2830 × 2430
requirements KLC 100mm thickness allows exibility in either Cool or Freezer room size; available in 400mm size increments to suit MISA’s patented “fast twin hook CAMLOCK system requires no sealants, so rooms can be easily assembled and disassembled. Please contact your local SKOPE representative for full details.
*Excludes installation faults AUS 1800 121 535 / NZ 0800 947 5673. Copyright © SKOPE Industries Limited. All rights reserved. SKOPE Industries Ltd reserves the right to alter specifications without notice. Visit www.skope.com for the most recent specification documents.