Preview only show first 10 pages with watermark. For full document please download

Mitsubishi Electric Pefy-wp Vms1

   EMBED


Share

Transcript

Air-Conditioners 2013 TECHNICAL & SERVICE MANUAL Models PEFY-WP15VMS1-E PEFY-WP20VMS1-E PEFY-WP25VMS1-E PEFY-WP32VMS1-E PEFY-WP40VMS1-E PEFY-WP50VMS1-E Safety Precautions Read before installation and performing electrical work ŒThoroughly read the following safety precautions prior to installation. ŒObserve these safety precautions for your safety. ŒThis equipment may have adverse effects on the equipment on the same power supply system. ŒContact the local power authority before connecting to the system. Symbol explanations WARNING This symbol indicates that failure to follow the instructions exactly as stated poses the risk of serious injury or death. CAUTION This symbol indicates that failure to follow the instructions exactly as stated poses the risk of serious injury or damage to the unit. Indicates an action that must be avoided. Indicates important instructions. Indicates a parts that requires grounding. Indicates that caution must be taken with rotating parts. (This symbol is on the main unit label.) Indicates that the parts that are marked with this symbol pose a risk of electric shock. (This symbol is on the main unit label.) WARNING Carefully read the labels affixed to the main unit. WARNING Do not use refrigerant other than the type indicated in the manuals provided with the unit and on the nameplate. Only use accessories (i.e., air cleaners, humidifiers, electric heaters) recommended by Mitsubishi Electric. Doing so may cause the unit or pipes to burst, or result in explosion or fire during use, during repair, or at the time of disposal of the unit. It may also be in violation of applicable laws. MITSUBISHI ELECTRIC CORPORATION cannot be held responsible for malfunctions or accidents resulting from the use of the wrong type of refrigerant. Do not make any modifications or alterations to the unit. Consult your dealer for repair. Improper repair may result in water leakage, electric shock, or fire. Do not touch the heat exchanger fins with bare hands. Ask your dealer or a qualified technician to install the unit. The fins are sharp and pose a risk of cuts. Improper installation by the user may result in water leakage, electric shock, or fire. Properly install the unit according to the instructions in the Installation Manual. Properly install the unit on a surface that can withstand its weight. Improper installation may result in water leakage, electric shock, or fire. Unit installed on an unstable surface may fall and cause injury. Only use specified cables. Securely connect each cable so that the terminals do not carry the weight of the cable. Have all electrical work performed by an authorized electrician according to the local regulations and the instructions in this manual. Use a dedicated circuit. Improperly connected cables may produce heat and start a fire. Insufficient power supply capacity or improper installation of the unit may result in malfunctions of the unit, electric shock, or fire. Take appropriate safety measures against wind gusts and earthquakes to prevent the unit from toppling over. Improper installation may cause the unit to topple over and cause injury or damage to the unit. HWE12090 i GB WARNING Keep electrical parts away from water. After completing the service work, check for a refrigerant leak. Wet electrical parts pose a risk of electric shock, smoke, or fire. If leaked refrigerant is exposed to a heat source, such as a fan heater, stove, or electric grill, toxic gases will be generated. Securely attach the control box cover. If the cover is not installed properly, dust or water may infiltrate and pose a risk of electric shock, smoke, or fire. Do not try to defeat the safety features of the unit. Only use the type of refrigerant that is indicated on the unit when installing or relocating the unit. Forced operation of the pressure switch or the temperature switch by defeating the safety features for these devices, or the use of accessories other than the ones that are recommended by Mitsubishi Electric may result in smoke, fire, or explosion. Infiltration of any other types of refrigerant or air into the unit may adversely affect the refrigerant cycle and may cause the pipes to burst or explode. Consult your dealer for proper disposal method. Consult your dealer or a qualified technician when moving or reinstalling the unit. Improper installation may result in water leakage, electric shock, or fire. Precautions for handling units for use with water CAUTION Do not use the existing water piping. Only use water. Store the piping materials indoors, and keep both ends of the pipes sealed until immediately before installation. Keep the joints wrapped in plastic bags. If dust or dirt enters the water circuit, it may damage the heat exchanger and cause water leakage. Only use clean water as a refrigerant. The use of water outside the specification may damage the refrigerant circuit. HWE12090 ii GB CONTENTS I Features [1] Features.................................................................................................................................... 1 II Components and Functions [1] Components and Functions...................................................................................................... 2 III Specfications [1] Specifications............................................................................................................................ 3 1.Specfications .......................................................................................................................... 3 2.Electrical component specifications........................................................................................ 5 IV Outlines and Dimensions [1] Outlines and Dimensions.......................................................................................................... 6 V Wiring Diagram [1] Wiring Diagram ......................................................................................................................... 8 VI Refrigerant System Diagram [1] Refrigerant system diagram.................................................................................................... 10 VII Troubleshooting [1] Troubleshooting ...................................................................................................................... 11 1.Check methods..................................................................................................................... 11 2.DC fan motor (fan motor/indoor control board)..................................................................... 13 3.Address switch setting .......................................................................................................... 14 4.Voltage test points on the control board ............................................................................... 15 5.Dipswitch setting (Factory setting)........................................................................................ 16 6.Instructions for debris removal operation.............................................................................. 18 7.Instructions for the air vent operation ................................................................................... 18 VIII Disassembly Procedure [1] Disassembly Procedure.......................................................................................................... 19 1.Control box ........................................................................................................................... 19 2.Thermistor (Intake air) .......................................................................................................... 20 3.Drainpan ............................................................................................................................... 21 4.Thermistor (Water outlet) (Water inlet) ................................................................................. 22 5.Fan and fan motor ................................................................................................................ 23 6.Bearing ................................................................................................................................. 24 7.Heat exchanger .................................................................................................................... 25 8.Drain pump ........................................................................................................................... 26 9.Float Switch .......................................................................................................................... 27 HWE12090 GB [ I Features ] I Features [1] Features Model Cooling capacity/Heating capacity kW HWE12090 PEFY-WP15VMS1-E 1.7/1.9 PEFY-WP20VMS1-E 2.2/2.5 PEFY-WP25VMS1-E 2.8/3.2 PEFY-WP32VMS1-E 3.6/4.0 PEFY-WP40VMS1-E 4.5/5.0 PEFY-WP50VMS1-E 5.6/6.3 -1- GB [ II Components and Functions ] II Components and Functions [1] Components and Functions 1. Indoor (Main) Unit (A) (A) Air (A) HWE12090 -2- GB [ III Specfications ] III Specfications [1] Specifications 1. Specfications Model PEFYWP15VMS1-E Power supply Cooling capacity Voltage V 220-240 Frequency Hz 50/60 *1 Current consumption *2 1.7 2.2 2.8 kW 1.9 2.5 3.2 Cooling kW 0.050 0.051 0.060 Heating kW 0.030 0.031 0.040 Cooling A 0.44 0.49 0.51 Heating A 0.33 0.38 0.40 External finish (Munsel No.) Dimensions Galvanized Height mm 200 Width mm 790 Depth mm 700 kg Net weight 19 Heat exchanger Fan Motor Type Sirocco fan x 2 Airflow rate (Low-Mid-High) m3/min 5.0-6.0-7.0 5.5-6.5-8.0 5.5-7.0-9.0 External static pressure Pa 5/15/35/50 5/15/35/50 5/15/35/50 Output kW 0.096 PP Honeycomb fabric (washable) Inlet in Rc3/4 screw Outlet in Rc3/4 screw Drain pipe dimensions Operating noise (Low-Mid-High) 20 Cross fin (Aluminium fin and cupper tube) Air filter Diameter of water pipe PEFYWP25VMS1-E kW Heating capacity *1 Power consumption *2 PEFYWP20VMS1-E mm [in.] 5Pa dB (A) O.D. 32 [1-1/4] 22-24-26 22-25-28 23-25-29 15Pa 22-24-28 22-25-29 24-26-30 35Pa 24-26-29 25-27-30 25-28-31 50Pa 24-27-30 25-28-32 25-29-33 *1 Indoor temperature: 27°CDB/19°CWB (81°FDB/66°FWB Outdoor temperature: 35°CDB (95°FDB) Indoor temperature: 20°CDB (68°FDB) Outdoor temperature: 7°CDB/6°CWB (45°FDB/43°FWB) *2 The external static pressure is set to 15Pa at factory shipment. HWE12090 -3- GB [ III Specfications ] Model PEFY-WP32VMS1-E Power supply Voltage V 220-240 Frequency Hz 50/60 Cooling capacity *1 Heating capacity Current consumption 3.6 4.5 5.6 kW 4.0 5.0 6.3 Cooling kW 0.071 0.090 0.090 Heating kW 0.051 0.070 0.070 Cooling A 0.61 0.73 0.77 Heating A 0.50 0.62 0.66 External finish (Munsel No.) Dimensions Galvanized Height mm Width mm Depth mm Net weight 200 990 Motor kg 25 Type Sirocco fan x 3 3/min Sirocco fan x 4 Airflow rate (Low-Mid-High) m 8.0-9.5-11.0 9.5-11.0-13.0 12.0-14.0-16.5 External static pressure Pa 5/15/35/50 5/15/35/50 5/15/35/50 Output kW 0.096 PP Honeycomb fabric (washable) Inlet in Rc3/4 screw Outlet in Rc3/4 screw Drain pipe dimensions Operating noise (Low-Mid-High) 27 Cross fin (Aluminium fin and cupper tube) Air filter Diameter of water pipe 1190 700 Heat exchanger Fan PEFY-WP50VMS1-E kW *1 Power consumption PEFY-WP40VMS1-E mm [in.] 5Pa dB (A) O.D. 32 [1-1/4] 26-29-32 29-31-34 29-32-35 15Pa 28-30-33 30-32-35 30-33-36 35Pa 30-32-35 31-34-37 31-35-39 50Pa 31-33-36 32-34-38 32-36-40 *1 Indoor temperature: 27°CDB/19°CWB (81°FDB/66°FWB Outdoor temperature: 35°CDB (95°FDB) Indoor temperature: 20°CDB (68°FDB) Outdoor temperature: 7°CDB/6°CWB (45°FDB/43°FWB) HWE12090 -4- GB [ III Specfications ] 2. Electrical component specifications Component Symbol Room temperature thermistor TH21 Water inlet pipe thermistor TH22 Water outlet pipe thermistor TH23 Fuse FUSE PEFYWP15VMS1-E , 10°C/9.6k , 20°C/6.3k , 25°C/5.4k , 30°C/4.3k , 40°C/3.0k Resistance 0°C/15k , 10°C/9.6k , 20°C/6.3k , 25°C/5.4k , 30°C/4.3k , 40°C/3.0k Resistance 0°C/15k , 10°C/9.6k , 20°C/6.3k , 25°C/5.4k , 30°C/4.3k , 40°C/3.0k 250V 6.3A 8-pole, Output 96W SIC-70CW-D8114-1 Power supply terminal block TB2 Transmission terminal block TB5 TB15 Symbol Room temperature thermistor TH21 Water inlet pipe thermistor TH22 Water outlet pipe thermistor TH23 Fuse FUSE Fan motor ) 330V 30A (1, 2), (M1, M2, S) 250V 20A Open/short detection Initial contact resistance 500 m PEFY-WP32VMS1-E or less PEFY-WP40VMS1-E PEFY-WP50VMS1-E Resistance 0°C/15k , 10°C/9.6k , 20°C/6.3k , 25°C/5.4k , 30°C/4.3k , 40°C/3.0k Resistance 0°C/15k , 10°C/9.6k , 20°C/6.3k , 25°C/5.4k , 30°C/4.3k , 40°C/3.0k Resistance 0°C/15k , 10°C/9.6k , 20°C/6.3k , 25°C/5.4k , 30°C/4.3k , 40°C/3.0k 250V 6.3A 8-pole, Output 96W SIC-70CW-D896-2 Power supply terminal block TB2 Transmission terminal block TB5 TB15 HWE12090 (L, N, DS Component Drain float switch PEFYWP25VMS1-E Resistance 0°C/15k Fan motor Drain float switch PEFYWP20VMS1-E DS (L, N, ) 330V 30A (1, 2), (M1, M2, S) 250V 20A Open/short detection Initial contact resistance 500 m -5- or less GB 25 A 2×E-ø2.9 2 Water pipe(To HBC unit) Rc3/4 screw 57 B C D 9 1000 1060 H 7 11 70 270 860 800 9 G 116 270 5 49 660 600 F 7 E 10 23 10 Air outlet 100 2×2-ø2.9 1 Water pipe(From HBC unit) Rc3/4 screw PEFY-WP15VMS1-E PEFY-WP20VMS1-E 700 752 798 660 PEFY-WP25VMS1-E PEFY-WP32VMS1-E 900 952 998 860 PEFY-WP40VMS1-E PEFY-WP50VMS1-E 1100 1152 1198 1060 Model D (Duct) 20 100×(E-1)=F 30 150(Duct) 23 25 64 102 -6100 900 700 500 J 24 20 16 K 790 M 1239 1190 1039 990 839 L A 90 M Control box Suspension bolt hole 4-14×30 Slot C L (To HBC unit) 2 Watetr pipe Rc3/4 screw (From HBC unit) 1 Water pipe Terminal bed(Transmission) Terminal bed(Power source) Drain pump Drain pipe(O.D.ø32) (Spontaneous draining) Drain pipe (O.D.ø32) 700 677 625(Suspension bolt pitch) Air inlet B (Suspension bolt pitch) 23 88 100×H=J 88 20 12 G 37 (Actual length) 65 -100 100 157.5 Knockout hole ø27 (Transmission wiring) 37 Drain hose (I.D. 32) Less than 300mm Knockout hole ø27 (Power source wiring) K-ø2.9 Air filter 100 HWE12090 20 12 Note 10 Provide an access door for maintenance at the bottom. 48 (B) 170 Space required for service and maintenance. 200 (A) Less than 550mm 15 [ IV Outlines and Dimensions ] IV Outlines and Dimensions [1] Outlines and Dimensions 1. PEFY-WP15, 20, 25, 32, 40, 50VMS1-E Unit : mm 1 Use M10 screw for the suspension bolt (field supply). 2 Keep the service space for the maintenance at the bottom. 3 This chart indicates for PEFY-WP32, 40VMS1-E models, which has 3 fans. PEFY-WP15, 20, 25VMS1-E models have 2 fans. PEFY-WP50VMS1-E models have 4 fans. 4 In case an inlet duct is used, remove the air filter (supply with the unit), then install the filter (field supply) at suction side. GB Fig.3 B Fig.1 A Electric box Ceiling Ceiling Intake air Ceiling beam Min.300mm Model N P Q R PEFY-WP15VMS1-E PEFY-WP20VMS1-E 700 50~150 800 1300 PEFY-WP25VMS1-E PEFY-WP32VMS1-E 900 150~250 1000 1500 PEFY-WP40VMS1-E PEFY-WP50VMS1-E 1100 250~350 1200 1700 Access door 3 Supply air Access door 2 (450×450) Electric box Intake air Ceiling beam Access door 2 (450×450) Min.10mm Supply air Min.10mm 50 50~150 700 450 Maintenance access space 100~200 Min.300mm Fig.4 (Viewed from the direction of the arrow B) 777 Access door 3 Bottom of indoor unit Electric box Access door 1 (450×450) 475 100~200 Min.300mm Maintenance access space 450 Fig.2 (Viewed from the direction of the arrow A) 450 Bottom of indoor unit Access door 1 (450×450) Electric box 475 700 (2) When a space of less than 300mm is available below the unit between the unit and the ceiling. (At least 20mm of space should be left below the unit as shown in Fig.3.) ·Create access door 1 diagonally below the electric box and access door 3 below the unit as shown in Fig.4. or ·Create access door 4 below the electric box and the unit as shown in Fig.5. (1) When a space of 300mm or more is available below the unit between the unit and the ceiling. (Fig.1) ·Create access door 1 and 2 (450x450mm each) as shown in Fig.2. (Access door 2 is not required if enough space is available below the unit for a maintenance worker to work in.) Min.20mm P 450 Q 450 N 450 N 50 -7- R 777 Access door 4 Bottom of indoor unit Electric box 700 Fig.5 (Viewed from the direction of the arrow B) 50 Min.300mm N HWE12090 Maintenance access space 50 [Maintenance access space] Secure enough access space to allow for the maintenance, inspection, and replacement of the motor, fan, drain pump, heat exchanger, and electric box in one of the following ways. Select an installation site for the indoor unit so that its maintenance access space will not be obstructed by beams or other objects. [ IV Outlines and Dimensions ] Unit : mm GB HWE12090 -8- 6 5 4 2 3 8 7 6 5 4 9 0 1 2 3 EF0 12 D 3 C 4 B 5 A 9 876 CN43 4 3 2 1 SW14 (Connection No.) SWC SWA SWB SW12 SW11 (10ths digit) (1s digit) 8 7 SW1 9 0 1 A. B. CN82 8 7 6 5 4 3 2 1 CN32 1 2 TB15 TO OUTDOOR UNIT TO MA REMOTE BC CONTROLLER CONTROLLER REMOTE CONTROLLER TB5 M1 M2 S(SHIELD) CN51 LED2 CN41 1 CN42 (Red) CN81 (Red) (Green) CN52 1 CN3A (Blue) 3 1 2 3 4 1 2 3 4 5 6 7 8 t° TH22 TH23 FS 1 2 3 4 1 2 3 4 t° CN4F 8 ON SWE OFF SW3 CN44 CN100 4 5 1 2 3 4 5 IT terminal *A CN27 (Red) CN90 SW4 t° LED1 CN20 (Red) TH21 1 2 ZNR01 U 1 M 1~ 3 (Blue) 5 1 CNP X1 3 Drainpump FUSE 1 TB2 L N L1 3 CN51 CN100 4 5 8 1 1 CN100 (Green) CN52 4 5 1 2 3 4 5 1 2 3 4 5 1 IT terminal (PAC-IT52AD-E) IT terminal (PAC-IT51AD-E) POWER SUPPLY ~220, 230, 240V 50, 60Hz BREAKER (16A) FUSE (16A) PULL BOX TO NEXT INDOOR UNIT L1: only PEFY-WP50VMS1-E In connecting optional IT terminal, use either CN51 or CN52 which is not connected. Be careful for connector colors. *A NOTE: Symbols used in wiring diagram above are, (HEAVY DOTTED LINE):FIELD WIRING (THIN DOTTED LINE) :OPTIONAL PARTS Fan motor MS 3~ 7 6 5 4 CNMF U CN2M (Blue) ZNR02 DSA 2 1 DC310~340V Rectify circuit SW2 CND (Black) I. B. INSIDE SECTION OF CONTROL BOX 8 [ V Wiring Diagram ] V Wiring Diagram [1] Wiring Diagram 1. PEFY-WP15, 20, 25, 32, 40, 50VMS1-E GB [ V Wiring Diagram ] Table.1 SYMBOL EXPLANATION SYMBOL NAME SYMBOL NAME SYMBOL NAME I.B. Indoor control board CN32 Connector (Remote switch) SW3 (I.B.) Switch (function setting) A.B. Address board CN41 Connector (HA terminal-A) SW4 (I.B.) Switch (function setting) TB2 Power supply terminal block CN51 Connector (Centralized control) SWE (I.B.) Connector (emergency operation) TB5 Transmission terminal block CN52 Connector (Remote display) SW1 (A.B.) Switch (function setting) TB15 Transmission terminal block CN90 Connector (Wireless) SW11 (A.B.) Switch (For setting the 1's digit in the address) FUSE Fuse AC 250V 6.3A CN100 Connector (IT terminal) SW12 (A.B.) Switch (For setting the 10's digit in the address) Float switch SW14 (A.B.) Switch (connection No.setting) ZNR01, 02 Varistor FS DSA Arrester TH21 Thermistor (inlet air) SWA (A.B.) Switch (static pressure setting) X1 Aux. relay TH22 Thermistor (water in) SWB (A.B.) Switch (function setting) L1 AC reactor (Power factor improvement) TH23 Thermistor (water out) SWC (A.B.) Switch (static pressure setting) Connector (Damper) SW2 (I.B.) Switch (capacity code setting) CN27 Note 1 Wiring to TB2, TB5, and TB15 indicated by the double-dashed lines is on-site work. 2 HWE12090 terminal block, connector. -9- GB [ VI Refrigerant System Diagram ] VI Refrigerant System Diagram [1] Refrigerant system diagram (G) (A) (B) (D) (E) (C) (F) (H) (A) Water outlet thermistor TH23 (B) Water outlet (C) Water inlet (D) Screw connections (E) Water inlet thermistor TH22 (F) Heat exchanger (G) Manual air purge valve (H) Room temperature thermistor TH21 Capacity PEFY-WP15, 20, 25, 32, 40, 50VMS1-E Water outlet Rc3/4 screw Water inlet Rc3/4 screw HWE12090 - 10 - GB [ VII Troubleshooting ] VII Troubleshooting [1] Troubleshooting 1. Check methods 1. Component and check points (1) Thermistor ŒRoom temperature thermistor (TH21) ŒWater inlet thermistor (TH22) ŒWater outlet thermistor (TH23) Disconnect the connector and measure the resistance between terminals with a tester. (Ambient temperature 10°C - 30°C) Normal 4.3k Abnormal - 9.6k Open or short (Refer to the thermistor characteristic graph below.) 1) Thermistor characteristic graph Low-temperature thermistor ŒRoom temperature thermistor (TH21) ŒWater inlet pipe thermistor (TH22) ŒWater outlet pipe thermistor (TH23) ŒDrain sensor (DS) 50 ŒThermistor R0 = 15 k 3% ŒMultiplier of B = 3480 k 2% 0°C 10°C 20°C 25°C 30°C 40°C 1 273+t 1 )} 273 30 (B) Rt = 15 exp { 3480( 40 15k 9.6k 6.3k 5.2k 4.3k 3.0k 20 (A) Temperature (°C) (B) Resistance (k ) 10 0 -20 -10 0 10 20 30 40 50 (A) (2) Fan motor (CNMF) Refer to the page on "DC fan motor (fan motor/indoor control board)." (3) Drain-up mechanism Measure the resistance between the terminals with a tester. (coil temperature 20°C) Normal Abnormal 1 3 HWE12090 340 Open or short - 11 - GB [ VII Troubleshooting ] (4) Drain float switch (CN4F) Disconnect the connector, and measure the resistance between terminals with a tester. (A) 1 2 3 4 (B) (C) (A) Moving part (B) Switch (C) Magnet (A) HWE12090 Position of the moving part Normal Abnormal Up Short (any position but short) Down Open (any position but open) - 12 - GB [ VII Troubleshooting ] 2. DC fan motor (fan motor/indoor control board) 1. CAUTION ŒA high voltage is applied to the connector for connection to the fan motor (CNMF). ŒDo not unplug the connector CNMF with the unit energized to avoid damage to the indoor control board and fan motor. 2. Troubleshooting ŒSymptom: Indoor unit fan does not run. Check fan motor connector contact (CNMF). Is the fan motor connector (CNMF) fully inserted? No Fix the connection. Yes Check the power supply. Measure the voltage at the indoor control board. 310 - 340VDC (same with the voltage between fan connector 1 (+) and 4(-)) Power supply voltage VDC 15VDC (same with the voltage between fan connector 5 (+) and 4(-)) 1 - 6.5VDC (same with the voltage between fan connector 6 (+) and 4(-)) [Values for Vsp are the values that are measured with the fan motor in operation. Vsp is 0V when the fan motor is stopped.] Is the voltage within the normal range? No Replace the indoor control board. Yes Check the fan motor position thermistor signal. Get the motor to make a full rotation or more, and measure the voltage at the test point VFG. (same with the voltage between fan connector 7 (+) and 4(-)) Are 0VDC and 15VDC displayed alternately? No Replace the motor. Yes Replace the indoor control board. HWE12090 - 13 - GB [ VII Troubleshooting ] 3. Address switch setting Make sure that power to the unit is turned off. (A) (B) ON OFF ON OFF 2 1 (A) Indoor unit control board (B) Factory setting (all models) 1. When using an ME remote controller, set the address with the rotary switches (SW11, SW12). ŒAddress setting is not required when the unit remote controller is used. On-site address setting is required for the indoor units to run. 2. Address settings vary in different systems. Refer to the section on address setting in the outdoor unit installation manual. 3. Address is set with a combination of SW12 (10's digit) and SW11 (1's digit). To set the address to "3," set SW12 to "0" and SW11 to "3." To set the address to "25," set SW 12 to "2" and SW 11 to "5." HWE12090 - 14 - GB [ VII Troubleshooting ] 4. Voltage test points on the control board 1. PEFY-P15, 20, 25, 32, 40, 50, 63VMS1(L)-E Fuse CND CNP С25(*1) CNMF C951(*1) Fuse Fuse(AC 250V 6.3A) CND Power supply voltage (220 240VAC) CN2M For M-NET transmission cable connection (24 - 30VDC) SWE Emergency operation SW2 Capacity setting SW4 Function setting CN42 For address board connection SW3 Function setting CN81 For address board connection CN32 Remote start/stop adapter CN3A For MA remote controller cable connection (10 - 13 VDC (Between 1 and 3.)) CN52 Remote display PC941(*1) CN51 CN2M CN41 JAMA standard HA terminal A CN44 Thermistor (water inlet/water outlet temperature) CN4F Float thermistor CN20 Thermistor (Inlet temperature) CN3C Indoor-outdoor transmission (0 - 24VDC) LED1 SWE SW2 CN3C CN20 SW4 CN42 CN4F CNMF Fan motor output 1 - 4: 310 - 340 VDC 5 - 4: 15 VDC 6 - 4: 0 - 6.5 VDC 7 - 4: Stop 0 or 15 VDC Run 7.5 VDC (0 - 15 pulse) CNP SW3 CN44 CN81 CN41 CN32 CN51 CN52 LED2 CN3A HWE12090 Centralized control Drain-up mechanism output (200VAC) (*1) VFG Voltage on the (-) side of PC941 and C25 (Same with the voltage between 7 (+) and 4 (-) of CNMF) VCC Voltage between the C25 pins 15 VDC (Same with the voltage between 5 (+) and 4 (-) of CNMF) Vsp Voltage between the C951 pins 0VDC (with the fan stopped) 1 - 6.5VDC (with the fan in operation) (Same with the voltage between 6 (+) and 4 (-) of CNMF) CN60 - 15 - GB [ VII Troubleshooting ] 5. Dipswitch setting (Factory setting) 1. Function setting (1) SW1 Switch position Function Switch setting ON OFF 1 Active Thermistor (Intake air thermistor) Built-in thermistor on the remote controller Indoor unit 2 Filter clogging detection Available Unavailable 3 Filter life 2500 hr 100 hr 4 Outdoor air intake Enabled Disabled 5 Remote display Thermo-ON signal Fan output 6 Humidifier operation During heating mode During heating operation 7 Fan speed Low Very low 8 Fan speed at heating Thermo-OFF Preset fan speed Follows the setting of SW1-7 9 Auto restart after power failure Enabled Disabled 10 Power start/stop Enabled Disabled 1) Adress board Factory setting (2) SW3 Switch position Function Switch setting ON 1 Unit type Cooling only OFF Heat pump 2 - - - 3 - - - 4 - - - 5 - - - 6 - - - 7 - - - 8 Heating 4-deg up Disabled Enabled 1) Indoor control board Dipswitch settings must be made while the unit is stopped. Factory setting HWE12090 - 16 - GB [ VII Troubleshooting ] 2. Capacity code setting (1) SW2 1) Indoor control board Dipswitch settings must be made while the unit is stopped. Factory setting The switches are set to correspond to the unit capacity. PEFY-WP15VMS1-E PEFY-WP20VMS1-E PEFY-WP40VMS1-E PEFY-WP50VMS1-E PEFY-WP25VMS1-E PEFY-WP32VMS1-E 3. Model setting (1) SW4 1) Indoor control board Dipswitch settings must be made while the unit is stopped. Factory setting Note: Changes made to the dipswitches SW1, SW2, and SW3 will become effective when the unit comes to a stop (remote controller off). There is no need to power cycle the unit. 4. External static pressure (1) SWA, SWC 1) Address board All models 5Pa 15Pa 3 3 2 2 1 1 1 1 SWA SWC SWA SWC 2 2 35Pa 50Pa 3 2 1 1 SWA SWC 3 2 1 1 SWA SWC 2 Factory setting 2 3 2 1 SWA (A) (B) 2 1 SWC (A) Option (B) Standard Note: Changes that are made to the dipswitches SWA and SWC immediately become effective regardless of the unit's operation status (RUN/STOP) or the remote controller status (ON/OFF). 5. 1's and 10's digits (1) SW11, SW12 (Rotary switch) The use of a network remote controller (PAR-F27MEA) requires address setting. 1) Address board Address settings must be made while the unit is stopped. Factory setting HWE12090 - 17 - GB [ VII Troubleshooting ] 6. Connection No. setting (1) SW14 (Rotary switch) This switch is used when the unit connected to an R2 series of outdoor unit. 1) Address board Factory setting Note: Changes to the dipswitches SW11, SW12, SW14, and SW15 must be made while the unit is stopped and the remote controller is OFF. 6. Instructions for debris removal operation Details are described in section [9] “Instructions for debris removal operation” under chapter IX Troubleshooting in the Service Handbook for the HBC. Refer to the figure below for the position of the air vent valve on the indoor unit. A A Air vent valve 7. Instructions for the air vent operation Details are described in section [9] “Instructions for debris removal operation” under chapter IX Troubleshooting in the Service Handbook for the HBC. Refer to the figure below for the position of the air vent valve on the indoor unit. A A Air vent valve HWE12090 - 18 - GB [ VIII Disassembly Procedure ] VIII Disassembly Procedure [1] Disassembly Procedure 1. Control box Exercise caution when removing heavy parts. 1. Removing the control box cover (1) Remove the two fixing screws on the cover (A) to remove it. (A) Fig.1 Fig.2 HWE12090 - 19 - GB [ VIII Disassembly Procedure ] 2. Thermistor (Intake air) Exercise caution when removing heavy parts. 1. Remove the control box cover according to the procedure in section 1. 2. Remove the thermistor. (1) Remove the two fixing screws on the metal base (B) to remove it. (B) Fig.3 (2) Pull out the thermistor holder (C) and thermistor (D) on the control box. P63 model only (C), (D) Fig.4 HWE12090 - 20 - GB [ VIII Disassembly Procedure ] 3. Drainpan Exercise caution when removing heavy parts. 1. Removing the filter and the bottom plate (1) Push down the tab on the filter, and pull out the filter in the direction of the arrow 1. (2) Remove the fixing screws on the bottom plate (D), (E) to remove it. (a) (a) (a) (a) (D) (E) Fig.5 2. Removing the drainpan (1) Pull out the drain pan in the direction of the arrow 1. Fig.6 Note ŒDrain the water out of the drain pan before removing it. ŒTo avoid dew condensation, use insulated screws in the places marked with circles in Figure 7. (a) (E) Fig.7 (a) HWE12090 - 21 - Insulation material GB [ VIII Disassembly Procedure ] 4. Thermistor (Water outlet) (Water inlet) Exercise caution when removing heavy parts. 1. Remove the drain pan according to the procedure in section 3. 2. Removing the Heat exchanger cover (1) Remove the four fixing screws on the heat exchanger cover (F) to remove it. HEX (F) Fig.8 3. Removing the thermistor (1) Remove the thermistor (G) from the thermistor holder (H) on the copper tube. Thermistor size Water in: ø8mm Water out: ø6mm (G) (H) Fig.9 HWE12090 - 22 - GB [ VIII Disassembly Procedure ] 5. Fan and fan motor Exercise caution when removing heavy parts. 1. Removing the filter and the bottom plate (1) Push down the tab on the filter, and pull out the filter in the direction of the arrow 1. (2) Remove the fixing screws on the bottom plate (J) to remove it. (a) (a) (a) (a) (J) Fig.10 (a) Tab 2. Removing the punching metal (1) Remove the two fixing screws on the punching metal (K) to remove it. (a) 3. Removing the fan casing (bottom half) (1) Squeeze the tabs on the fan casing to remove it in the direction of arrow 2. (K) Fig.11 4. (1) 5. (1) Removing the motor cable Remove the motor cable threw the rubber bush. Removing the fan motor and the Sirocco fan Remove the two motor fixing screws to remove the motor and the Sirocco fan in the direction of arrow 3. Fig.12 (2) Remove the four fan case fixing screws to take the top half of the fan casing off. Fig.13 HWE12090 - 23 - GB [ VIII Disassembly Procedure ] 6. Bearing P40, P50, P63 models only. Exercise caution when removing heavy parts. 1. Removeing the bearing (1) Remove the two fixing screws on the bearing cover (M) to remove it. (M) Fig.14 (2) Remove the two bearing retainer screws to remove the bearing. Fig.15 HWE12090 - 24 - GB [ VIII Disassembly Procedure ] 7. Heat exchanger Exercise caution when removing heavy parts. 1. Remove the drain pan according to the procedure in section 3. 2. Remove the heat exchanger cover according to the procedure in section 4 2. 3. Removing the cover (1) Remove the two fixing screws on the cover (T) to remove it. (T) Fig.16 (T) Pipe support plate 4. Removing the Heat exchanger (1) Remove the fixing screws on the heat exchanger (S) to remove it. (S) Fig.17 HWE12090 - 25 - GB [ VIII Disassembly Procedure ] 8. Drain pump Exercise caution when removing heavy parts. 1. Remove the drain pan according to the procedure in section 3. 2. Removing the air-vent pipe (1) Remove the air-vent pipe (a) from the cable strap (b). (b) (a) Fig.18 3. Removing the drain pump (1) Remove the four screws that are holding the drain pump and the float switch in place. Fig.19 HWE12090 - 26 - GB [ VIII Disassembly Procedure ] 9. Float Switch Exercise caution when removing heavy parts. 1. Remove the drain pan according to the procedure in section 3. 2. Removing the air-vent pipe (1) Remove the air-vent pipe (a) from the cable strap (b). (b) (a) Fig.20 3. Removing the drain pump (1) Remove the four screws that are holding the drain pump and the float switch in place. Fig.21 4. Removing the float switch (1) Remove the two screws that are holding the float switch in place. Fig.22 HWE12090 - 27 - GB Feb. 2013 HWE12090 Printed in Japan New publication, effective Feb. 2013 Specifications subject to change without notice