Preview only show first 10 pages with watermark. For full document please download

Mmp-10

   EMBED


Share

Transcript

MMP-10 INSTRUCTION MANUAL Multiplexer Quality Cinema Products Ultra★Stereo Labs, Inc. • 181 Bonetti Drive San Luis Obispo, CA 993401 Telephone 805.549.0161 • e-mail [email protected] MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. Limited Warranty ★★★★★ Ultra★Stereo Labs , Inc. warrants that the MMP-10 will be free from defects in material and workmanship under normal usage for a period of ninety (90) days after its purchase new from an authorized dealer. Our obligation under this warranty is limited to repairing or replacing any product or component which we are satisfied does not conform with the foregoing warranty and which is returned to our factory, freight paid, or serviced by one of our authorized contractors. The foregoing Warranty is exclusive and in lieu of all other warranties, whether expressed or implied. Such warranty shall not apply to any product or component (A) repaired or altered by anyone other than Ultra★Stereo Labs or an authorized service contractor; (B) tampered with or altered in any way or subjected to misuse, negligence or accident or (C) which has been improperly connected, installed or adjusted otherwise than in accordance with Ultra★Stereo Labs instruction. This warranty does not cover damage to surface finishes, normal wear, or failure resulting from abuse. Rev 110598 -2- MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. Table of Contents Features ................................................... 4 How It Works ........................................... 5 Initial Calibration ..................................... 6 Setup Procedure ....................................... 7 Microphone Placement ............................ 8 Microphone Mounting ............................. 9 Low Battery Indicator ............................... 9 Remote Switch Circuits .......................... 10 Specifications ......................................... 11 Please record the following information for your records: Model: ___________________ Serial Number: ___________ Date of Purchase: __________ Purchased from: __________ -3- MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. MMP-10 Features 1 Four laboratory grade test microphones. Each microphone is calibrated with its multiplexer to insure utmost accuracy. 1 2 PUSH PUSH SWITCH CRAFT PUSH SWITCH CRAFT SWITCH CRAFT PUSH SWITCH CRAFT (Top View) Individual microphone selection or sequential scan. Adjustable scan rate. Blinking low battery indicator. Overall output level adjust. Works with any audio spectrum analyzer. Small diameter, lightweight umbilical cable from the multiplexer to your analyzer. 2 Theater microphone seat mounts included. Rugged construction. Mic.1 Mic.2 Mic.3 Mic.4 Power Low Battery Indicator M icrophone M ultiplexer MMP-10B Quality Cinema Products (Front View) -4- MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. How It Works The MMP-10 contains four high quality microphone preamplifiers, followed by an adjustable switching circuit. Microphone signals are routed through the unit in several different configurations. On powerup, only microphone one is amplified and routed through the MMP-10 to your analyzer. The remote switch at the analyzer end of the MMP-10 cable permits selection of other microphones. Pressing the switch once selects microphone two. Press it again and microphone three is selected; once more and microphone four is selected. Pressing it once again starts automatic scan mode, which cycles through all four microphones, one at a time. Pressing it one more time resets the MMP-10 to microphone one. Typical analyzer equipment is shipped with only a single microphone. The MMP-10 allows you to expand your equipment to four microphones. [Such multi-microphone measurement techniques achieve far superior acoustical results in auditoriums due to the averaging effect.] LED Displays On/Off Output Micr. Inputs Low Battery Indicator PUSH PUSH PUSH PUSH M icrophone M ultiplexer Quality Cinema Products MMP-10B SWITCH CRAFT MMP-10 Front SWITCH CRAFT SWITCH CRAFT SWITCH CRAFT MMP-10 Top -5- MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. Initial Calibration The first time you use your new MMP-10, you should set the output level to match the single microphone supplied with your analyzer. To accomplish this find a suitable location and set up your analyzer with its own microphone. Using pink noise through the sound system, adjust the amplifier level to produce a normal display (85 dbC). Next disconnect the analyzer microphone and connect the MMP-10 (with its four microphones) to the analyzer. Open the MMP-10 back cover. Select microphone one and adjust the overall potentiometer R# 45 inside the MMP-10 to achieve the same level on your analyzer display as measured with the analyzer microphone. Verify that the remaining three microphones have the same reading. (Note: it is not necessary to adjust individual trim potentiometers, R10, R20, R30, R40, as these are adjusted at the factory.) Switch the MMP-10 to scan mode and observe the display of all four microphones. Different analyzers will integrate this switched signal in various ways. Adjust the scan rate potentiometer, R60, to achieve a smooth stable display. If the timing is too slow, the display will bounce. Level R49 R51 R50 R48 R56 R57 C16 4 + P R32 D5 R12 D3 C17 R62 34184 4052 C20 C15 U7 4520 C33 C32 R2 C35 R23 R24 R25 R26 R13 R14 R15 R16 U2 C18 R63 U8 C1 1 D2 C12 C7 R33 R34 R35 R36 R44 R42 R43 R41 C24 R55 R61 D1 R54 + P R1 R39 R29 R38 R37 R28 R27 MIC4 R40 MIC3 U6 C13 C8 C9 R5 R6 C27 C3 R19 MIC2 C10 R9 R8 R18 R17 C14 R30 C2 R3 R4 U1 C19 U4 - C6 2 C28 R54 R52 R53 C26 + P R22 D4 U3 R55 U9 - R11 R45 9v C23 C11 3 C21 OUT Acme Battery Corp. Steekingdesert, New Mexico. - R21 R55 R47 R46 R54 C22 C29 4011 B1 + P R31 34184 - R7 R20 MIC1 U5 C31 C25 C4 C5 R10 FREQ C30 4011 - 34184 E OUT S1 R64 4011 + C34 R60 MIC MULTIPLEXER MMP-10B USL, INC. TARZANA, CA R58 R59 Micr. Trims Freq. Scan -6- MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. Setup Procedure Locate the MMP-10 approximately 2/3 back from the screen, off axis of the center speaker, usually between the center speaker and the right speaker to allow for viewing from the booth. Place microphone one at this position. Place the remaining mics. in a diamond pattern within the central area of the room. The microphones should be positioned horizontally with the microphone’s screen facing up, toward the ceiling (Figure2). Insert the microphone connectors into the appropriate jacks on the MMP-10. Connect the audio cable to the MMP-10 and switch the unit on. The red LED for microphone one will be on. Be sure to position the MMP-10 so you can view the LED display from the booth. Plug the other end (i.e. momentary switch side) of the audio cable into your analyzer up in the projection booth. Switch on Pink Noise. Your MMP-10 wakes up with microphone one selected. Verify you have a signal from microphone one on your analyzer. Select microphone two, three then four to verify operation. Select multiplex mode (indicated by the LEDs flashing in order: red, green, green green) and set your analyzer to the proper level and commence room equalization. The multiplexer has been designed to allow for easy room averaging with a small but accurate four microphone multiplexer system. Room equalization using only one microphone is not recommended due to room modes. Using four microphones and MMP-10 multiplexer will allow for the best sound for the greatest number of seats in the room. Remote control of the MMP-10 is achieved by using a momentary in-line push button located on the audio cable plugged into your analyzer. Pressing the button located on this cable cycles the MMP-10 through five states: Microphone 1, microphone 2, microphone 3, microphone 4 and multiplex (scan) mode. -7- MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. Ideal Microphone Placement 2 4 1 3 Mic.1 Mic.2 Mic.3 Mic.4 Power Low Battery Indicator Projector M icrophone M ultiplexer Quality Cinema Products MMP-10B To Analyzer MMP-10B Figure 1 The microphones should be placed in the listening environment as shown above (Figure 1). Variations may apply depending upon size and shape of the auditorium but a diamond formation is best for overall sound field measurement. -8- MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. Mounting the Microphone Microphone mounting: Microphone Mount the microphone to the telescoping stand as shown (Figure 2) and place the stands in the desired locations (Figure 3) in the theater or other venue. Clip Microphone Telescoping Stand Telescoping Stand Figure 2 Seat Mounting Figure 3 Low Battery Indicator Low battery voltage can cause the unit to not switch properly, and may cause measurement errors. To avoid this, the MMP-10 incorporates a low battery sensing circuit. When the battery voltage drops too low, the unit will reset to microphone one, and the red LED will blink. Replace the battery with a standard 9V alkaline battery. -9- MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. Remote Switch Circuits A 3–pin female cord plug with a momentary on/off switch is a standard item in the MMP-10S kit. This switch cord will work with most balanced input analyzers. 3 PIN SWITCH CIRCUIT Pin 2 (+) To MMP-10 33µf NP 1k 100k 390Ω Pin 1 (Gnd) 100k 390Ω Pin 3 (-) 33µf NP 1k MMP Adapters The MMP-10 output is a 3–pin female XLR connector. Included is an adapter to a 3–pin male XLR connector (MMP-ADS). Other adapters are available to convert to almost any analyzer or sound processor: Model # Connector Type For Use With MMP-ADS 3–pin XLR (male) Audio Control, Gold Line, Abacus ARTA-160, Clark Techniq, HP-8050 MMP-AD1 6–pin XLR (female) Ivie 30, Ivie PC-40 MMP-AD2 3–pin Mini-XLR (male) Abacus ARTA-80 MMP-AD5 1/8" Stereo Phone Plug Dolby CP-500 - 10 - MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. Specifications (1K ohm load on each leg of the balanced output) Nominal microphone input level: -54 dB (2mv) Maximum output level: -27 dBV (43mV) adjustable Output impedance: 2K ohms Number of microphone channels: 4 Individual microphone channel adjustment range: 9dB Microphone scan rate: 7 to 21 Hz adjustable Power source: 9 volt battery Current drain: Approx. 20 ma. Meets CE Approval Standards Factory Settings (1K ohm load on each leg of the balanced output) Output level: 15mV (-36 dB) Microphone scan rate: 10Hz - 11 - MMP-10 INSTRUCTION MANUAL ULTRA★STEREO LABS, INC. Ultra★Stereo Labs, Inc. 181 Bonetti Drive San Luis Obispo, CA 93401 USA Telephone 805.549.0161 FAX 805.549.0163 e-mail [email protected] - 12 - Quality Cinema Products © 1996, 1998 Ultra★Stereo Labs, Inc. San Luis Obispo, CA, USA. All Rights Reserved