Modbus Ethernet Opc Server Overview Supported Devices: Features:

   EMBED


Share

Transcript

Modbus Ethernet OPC Server Overview Kepware's 32 bit Modbus Ethernet device driver works in conjunction with our OPC Server KEPServerEX, to provide data exchange between OPC Clients and Modbus Ethernet protocol compliant PLCs. Kepware's implementation of Modbus Ethernet supports master and slave operations simultaneously. The slave mode allows the server to receive data by exception from other Modbus Ethernet devices. KEPServerEX automatically optimizes your data acquisition based on client demand. Data integrity is ensured with our extensive error handling. The Modbus Ethernet driver now offers direct integration with Modicon Concept and ProWORX programming packages. If you are using either of these packages you will be able to directly import the tags used in your PLC application directly into KEPServerEX. This time saving step makes all of the relevant PLC data available to your OPC client applications instantly. This driver is part of the Modicon Modbus Communications Suite. Purchasing either the Modbus RTU serial, Modbus RTU Slave serial, Modbus ASCII serial, Modbus Plus SA85, or the Modbus Ethernet TCP driver entitles you to all five drivers. Supported Devices: Device Note Modbus Ethernet n/a Mailbox Consult your Modicon Documentation on the MSTR instruction for sending unsolicited requests to the Modbus Ethernet driver. Fluenta FGM n/a Roxar RFM n/a Features: Specific Features ƒ Automatic Tag Database Generation. ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ Supports Multiple PLCs via IP addressing. Supports Modicon Ethernet to Modbus Plus bridging. Supports Multiple or Single socket usage for better gateway resource management. Supports Tag import from Concept and ProWORX programming packages. Supports Memory Accesses to 65535. Hex Addressing Support (0-FFFF). User Definable Read Block Sizes. Adjustable Address Base ( 0 or 1 ). Word Order Swapping for Floating Point and Longs. 0xxxx - Output Coils, 1xxxx - Input Coils, 3xxxx - Internal Registers, 4xxxx - Holding Registers. All data types and arrays are supported. General Features General ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ ƒ Multi-threaded design ensures optimum performance Supports up to 16 concurrant serial port and PC card configurations Full Time On-line operation allows on the fly changes Build Diagnostic system with protocol display OPC Diagnostic feature provides a real-time and historical view of OPC events that occur between any OPC client and the server. Modem support included on all Serial port drivers CSV file import and export of Server tags for easy configuration on large projects Supports running as a Windows service Supports direct scaling of device data which allows raw device data to be converted to engineering units for OPC client applications Online full-time Includes a built-in User Manager that allows complete control over what types of functionality each individual user can access Allows the user to specifically select a NIC card for use with any Ethernet driver or serial driver running in Ethernet Encapsulation mode. OPC ƒ ƒ ƒ ƒ Supports OPC 1.0 Data Access Specifications Supports OPC 2.05a Data Access Specifications Supports OPC 3.0 Data Access Specifications Includes OPC 2.0 Automation Interface and comprehensive Visual Basic examples DDE ƒ ƒ ƒ ƒ AdvancedDDE supports RSView32 and Cimplicity FastDDE and SuiteLink Support Wonderware FactorySuite 2000 CF-Text supports all DDE aware applications NetDDE supports shared network access to device data Required Software and Hardware Supported Operating Systems ƒ ƒ ƒ Windows NT Windows 2000 Windows Server 2003 ƒ Windows XP PC Hardware Minimum ƒ ƒ ƒ 400 Mhz Pentium CPU 128 Megs of RAM 100 Megs of Free Hard Drive Space Recommended ƒ ƒ ƒ 600 Mhz Pentium CPU 512 Megs ofRAM 100 Megs of Free Hard Drive Space Hardware Requirements ƒ For Device and Hardware Requirements see the Devices table. Communications Protocol: ƒ Modbus Ethernet