Preview only show first 10 pages with watermark. For full document please download

Model: 12hrl200 Stored Energy Solutions For A

   EMBED


Share

Transcript

stored energy solutions for a demanding world HRL Series Model: 12HRL200 The HRL range of VRLA batteries with 12+ years design life is perfectly suited to any application which requires a high rate current over a short period. In particular they are ideal for IDC and UPS systems thanks to their optimized performance and a patented post seal design. Meanwhile with excellent uniform battery performance, long deign life wide usage temperature range, HRL series are suit for high ambient temperature. 208mm(8.19inch) 211mm(8.31inch) Dimensions-mm[inch] 138mm(5.43inch) 230mm(9.06inch) Specifications Battery Model 12HRL200 Nominal Voltage 12V Rated Capacity 200 W/cell(15 minute rate, 1.75 V/cell) and 55Ah(10 hr to 1.80V/cell) @25 OC (77 OF ) Typical Weight 17.5kg Internal Resistance Approx 8.0mΩ Operation(maximum): Operation(recommended): Temperature Ranges Storage: -40 OC to 55 OC( -40 OF to 131 OF) O O O O 15 C to 25 C( 59 F to 77 F) -20 OC to 40 OC( -4 OF to 104 OF) O Float Voltage O 2.27V/cell@25 C (77 F ) Recommended Maximum Charging Current Limit 15A Equalize and Cycle Serivice 2.35V~2.40V@25 OC (77 OF ) The residual capacity is above 87% after 90 days storage(25 OC /77 OF ) Self Discharge Terminal M6 Female Terminal Hardware Torque 10 ± 1.0Nm Container Material ABS (V0 optional) Constant Current Discharge Characteristics Units: Amperes (25 O C, 77 OF) End voltage per cell 5min 10min 15min 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 1.90V 171 160 155 150 143 134 102 135 127 123 118 110 104 78.1 118 114 110 106 103 97.5 70.4 20min 92.3 86.9 84.6 80.6 78.0 75.2 63.8 30min 66.3 63.9 62.8 60.5 57.9 56.0 49.4 Discharge Data with Constant Power End voltage per cell 5min 10min 15min 20min 1.60V 1.67V 1.70V 1.75V 1.80V 1.85V 1.90V 301 284 277 271 262 252 187 242 232 226 217 207 198 150 216 210 206 200 194 188 144 170 162 158 153 148 145 119 30min 123 120 118 115 111 108 92.2 40min 53.3 52.2 51.2 50.1 49.0 48.2 40.0 50min 43.5 42.2 41.4 40.5 40.1 39.2 34.1 1h 36.6 36.2 35.9 35.5 34.1 33.3 30.2 2h 21.2 21.0 20.8 20.6 20.2 19.2 18.2 3h 14.3 14.1 14.0 13.9 13.6 13.4 12.3 4h 5h 6h 8h 10h 11.6 11.5 11.4 11.3 10.9 10.7 9.57 9.74 9.68 9.57 9.46 9.13 8.69 8.03 8.36 8.31 8.25 8.09 7.98 7.54 6.82 6.68 6.57 6.51 6.40 6.34 6.05 5.66 5.83 5.76 5.72 5.64 5.50 5.23 4.88 O O Units:Watts per cell (25 C, 77 F) 40min 93.8 92.8 91.7 90.6 90.0 89.6 74.7 Copyright Narada Power Source Co.,ltd. www.naradapower.com 50min 76.9 75.8 74.7 73.7 74.2 73.1 64.1 1h 65.2 64.5 64.0 63.0 62.0 60.0 57.2 2h 38.6 38.4 38.1 38.6 38.0 36.1 34.4 3h 26.2 26.1 25.9 26.1 25.5 25.2 23.4 4h 5h 6h 8h 10h 21.5 21.3 21.3 21.0 20.5 20.3 18.2 18.1 18.1 17.9 17.9 17.3 16.6 15.4 15.7 15.6 15.5 15.4 15.2 14.4 13.0 12.5 12.4 12.3 12.2 12.1 11.6 10.9 11.0 11.0 10.9 10.8 10.5 10.1 9.50 stored energy solutions for a demanding world HRL Series Model: 12HRL200 Terminal Voltage(V) Vs. Discharge Time (25O C, 77OF) Discharge Voltage(V) 13 12 11 0.05CA 0.25CA 0.6CA 1CA 9 Charge Characteristic (%) (CA) (V) Constant Charge At 0.20CA-14.4V(25℃) 120 Charge Charge Capacity 14 Voltage 100 0.1CA 10 Ch arge Curr ent Char ge Volt ag e Ch arge Capac ity Battery Voltage Vs.Charge Time 80 0.20 60 0.15 40 0.10 20 0.05 13 100%Charge 8 0 2 6 12 30 60 3 Min 10 20 h 0 12 50%Charge 11 Charge Current 0 0 2 4 6 8 10 12 Time(hour) Relationship of OCV Vs. State of Charge Capacity Retention Characteristic 13.5 100 12.0 75 O O 10 C(50 F) 50 O 40 C(104 OF) 30 OC(86 OF) 3 9 O O 20 C(68 F) 25 11.5 11.0 0 10 20 30 40 50 60 70 80 90 6 12 15 100 Remained Capacity(%) Charging Procedures 18 21 24 27 Storage Time(month) Discharge Current VS. Discharge Voltage Charge Voltage (V/Cell) Application Cycle Temperature O 25 C Set Point Allowable Range 2.40 2.35~2.45 Max. Charge Current 15A Standby O 25 C 2.27 Final Discharge Voltage V/Cell Discharge Current (A) 1.80 10A≥I 1.70 10A50A 2.23~2.27 Zhejiang Narada power source Co., Ltd. Add:Building A, No.822 Wen'er West Road, Zhejiang, China Tel: (86 571)56975980 Fax:(86 571)56975955 Email: [email protected] Website: www.naradapower.com 12HRL200-02-EN(OB) January 2016 Subject to revision without prior notice.E.&.O.E. 12.5 Capacity(%) OCV (V) 13.0