Preview only show first 10 pages with watermark. For full document please download

Model 354n

   EMBED


Share

Transcript

Controllers Model 354N Universal Loop Controller Introduction Features & Benefits Multiple loop capability provides control, logic, and sequencing functions to accommodate comprehensive process control needs Graphical configuration program allows use of function block and ladder logic languages in a control strategy configuration Scalable hardware minimizes initial costs, while providing for easy future expansion 2 Factory Configured Options (FCOs) minimize configuration time and expense Standard DB9/M connector provides easy connection to a PC for configuration, operation, monitoring, and troubleshooting RS485 Modbus network provides easy connection to a workstation via a multi-drop network for configuration, operation, monitoring, and troubleshooting Optional local faceplate provides full monitoring and controller configuration capabilities The ability to connect to the Local Instrument Link (LIL) in place of the MODBUS network provides higher speed and peer-to-peer communication Password protection provides individual security for various plant personnel LonWorks® digital fieldbus provides flexible I/O expansion and reduced wiring costs for continuous and discrete variables Coated circuit boards ensure reliable operation and environmental integrity Removable Real Time Clock/Configuration Board (RTC/ CB) option minimizes maintenance and complexity via a simple board replacement technique that stores a complete copy of the control strategy configuration Description The Model 354N Universal Loop Controller, a stand-alone, microprocessor-based industrial controller designed for use in a broad range of applications, is a wall-mounted version of the Model 353 Process Automation Controller. As such, it can function as a simple single-loop controller or as a multiloop controller providing complete control and logic for a small unit batch or continuous process. Moreover, the Model 354N’s fieldbus and networking options enable it to function as an integral element in a plantwide control system. 2.10 Each of the Model 354N’s configured loops can have a virtual operator faceplate for monitoring from the optional local faceplate, a local flat panel PC, or plant workstation. Station events, such as alarms and actions, are mapped to the controller network to enable the local PC or workstation to provide alarm and event management consistent with the local faceplate. Loop pushbuttons also provide dual operation from the faceplate or the operator PC. This product consistency allows the local faceplate to afford full backup monitoring and configuration capabilities in case of a network or PC failure. The Model 354N’s pre-configured library of FCOs enables selection of common basic controller types for quick field configuration and set-up. A large selection of reusable function blocks enable simple changes to FCOs or the design of a custom control strategy to meet a variety of process control applications. The Graphical 353 Configuration software accommodates configuration design, downloading, uploading, and on-line monitoring capabilities for improved management of control configurations. In addition, sequencer/ logic loops can be configured and monitored on-line in ladder logic format for those more familiar with this language. Controllers Model 354N Universal Loop Controller Technical data Specifications Analog Input, Universal (isolated) Electrical & Environmental Power Requirements Thermocouple: J, K, T, E, S, R, B & N RTD: DIN 43760, US (NBS126), JIS C-1604 Slidewire: 500-5000 Ohms: 0-5000 Millivolt: -19.5 to 78 mVdc I/O Expander Board: Qty 2 25 Watts, 40 VA (max.) Digital/Frequency Input, Universal (isolated) 2-Wire Transmitter Power Frequency Range: 0 to 25,000 Hz Minimum Operating Frequency: 0.05 Hz ON Voltage: 4-30 Vdc OFF Voltage: 0-1 Vdc Input Current: <5 mA @ 30 Vdc I/O Expander Board: Qty 2 Power Supply Standard: 120/240 Vac (85 to 264 Vac); 47 to 63 Hz Voltage: 25 Vdc ±3V Current: 120 mA, short circuit protected Hazardous Area Approvals Pending CSA (NRTL): Class I, Div. 2, Groups A, B, C & D CE (Consult Siemens for current approvals) Ambient Temperature Range Operating: 32 to 122°F (0 to 50°C) Storage: -40 to 185°F (-40 to 85°C) 2 Outputs Analog Outputs (non-isolated) Climate Conditions - IEC654-1 4-20 mA into 800 ohms (max.) MPU Controller Board: Qty 2 I/O Expander Board: Qty 1 Class B3 - Standard Mounting Digital Outputs (non-isolated) Electrostatic Discharge IEC 801-3 Open Collector Transistor (emitter @ station common) Load Voltage: 30Vdc (maximum) Load Current: 100 mA (maximum) Off State Leakage Current: <200 mA @ 30 Vdc MPU Controller Board: Qty 2 Electrical Transients Relay Outputs (SPDT) IEC 801-4 Contact Rating: 5A @ 120 Vac, 2.5 A Resistive Load @ 230Vac Minimum Current: 100 mA @ 10 mVdc150 mA @ 50 mVac I/O Expander Board: Qty 2 IEC 801-2 RFI Protection Net Weight Controller: 4.5 lbs (2 kg) Faceplate: 0.3 lbs (0.14 kg) Heat Dissipation 80 BTU/Hr. Scan Time Optional Boards Local I/O Expander LonWorks Remote I/O Bus Local Instrument Link Network Real Time Clock/ Configuration Board Varies with configuration: 20 msec (minimum) Standard Configuration Inputs Analog Inputs (non-isolated) 1-5 Vdc, 4-20 mA with included 250 resistor MPU Controller Board: Qty 3 I/O Expander Board: Qty 1 Nine of the most common control strategies have been stored in a built-in library and can be selected with a single push-button entry. These control strategies, which can be customized to accommodate individual needs, are: Single-Loop Controller with Tracking Setpoint Digital Inputs (isolated) Single-Loop Controller with Fixed Setpoint 0-1 Vdc OFF, 15-30 Vdc ON MPU Controller Board: Qty 3 I/O Expander Board: Qty 1 Ratio Set Controller with Operator Setpoint Limits Single-Loop Controller with Operator Setpoint Limits Cascade Loop Controller Cascade Loop Controller with Operator Setpoint Limits Ethernet Set Controller with Tracking Setpoint External Setpoint with Fixed Setpoint Dual Loop controller 2.11 Controllers Model 354N Universal Loop Controller Technical data Function Blocks Control strategies within the Moore 354N are configured using the following function blocks, which are stored in memory. The total number and type of I/O function blocks available in the Moore 354N depend on the installed hardware, and when available, can be used as needed within a configured loop. Loop function blocks can be used in the quantities indicated within each loop. Each configured loop can contain one operator display block & one controller block*. 2 Station Hardware I/O AIN1-4 - Analog Input AINU1-2 - Analog Input Universal AOUT1-3 - Analog Output DIN1-4 - Digital Input DINU1-2 - Digital Input, Universal DOUT1-2 - Digital Output ROUT1-2 - Relay Output LIL Peer To Peer Global Data I/O AIL01-99 - Analog Input_LIL AOL01-99 - Analog Output_LIL DIL01-99 - Discrete Input_LIL DOL01-99 - Discrete Output_LIL Lonworks Remote I/O AIP01-25 - Analog Input lev_Percent AOP01-25 - Analog Output lev_Percent DID1-6 - Digital Input lev_Discrete,16 Chan. DOD1-6 - Digital Output lev Discrete,16 Chan. DIS1-6 - Digital Input_State DOS1-6 - Digital Output State Loop Function Blocks A/M - Auto/Manual ACS01-99 - ARC Cosine ADD01-99 - Addition AGA3 - Orifice Metering of Natural Gas AGA7 - Measurement of Gas by Turbine Meters AGA8 - Compressibility Factors of Natural Gas ALARM - Alarm AND01-99 - AND Logic ASN01-99 - ARC Sine ATD01-05 - Analog Trend Display ATN01-09 - Arc Tangent BATOT - Batch Totalizer BATSW - Batch Switch BIAS - Bias CHR01-99 - Characterizer CMP01-99 - Comparator COS01-99 - Cosine DAM01-99 - Deviation Amplifier DIV01-99 - Division DNC01-99 - Divide by N Counter DTM01-99 - Dead Time Table DYT01-99 - Delay Timer E/I - External/Internal Transfer ESL - Event Sequence Logger EXP01-99 - Natural Exponentiation EXT01-99 - Exponentiation FTG01-99 - Falling Edge Trigger GB01-99 - Gain & Bias HLD01-99 - Hold ID* - ID Controller LL01-99 - Lead/Lag 2.12 LMT01-99 LN01-99 LOG01-99 MTH01-99 MUL01-99 NND01-99 NOR01-99 NOT01-99 ODC* ODS* ONOFF* - Limit Natural Logarithm Logarithm Base 10 Math Multiplication NAND Logic NOR Logic NOT Logic Operator Display for Controllers Operator Display for Sequencers ON OFF Controller ODA - Operator Display for Analog ODD - Operator Display for Discrete ODP - Operator Display for Pushbutton OR01-99 ORSL OST01-99 PB1SW PB2SW PB3SW PCOM PD* PID* PIDAG* PRSEQ QHD01-99 RATIO RCT01-99 RLM01-99 ROT01-99 RSF01-99 RTG01-99 SCL01-99 SEL01-99 SETPT SIN01-99 SPLIM SRF01-99 SRT01-99 SUB01-99 TAN01-99 TH01-99 TSW01-99 TOT01-99 XOR01-99 - OR Logic Override Selector One Shot Timer PB1 Switch PB2 Switch PB3 Switch Phase Communication PD Controller PID Controller PIDAG Controller Program Sequencer Quickset Hold Ratio Repeat Cycle Timer Rate Limiter Retentive On Timer RS Flip-Flop Rising Edge Trigger Scaler Signal Selector Setpoint Sine Setpoint Limit SR Flip-Flop Square Root Subtraction Tangent Track & Hold Transfer Switch Totalizer Exclusive OR Logic Accessories Graphical Configuration Software (P/N 15939-74 Vx.xx1, Consult Siemens for latest version) Windows® 95/NTTM software for configuration of the Model 354N and creation of the function block diagram. Configurations can be transferred using the built-in front panel connector, the Modbus network, or the LIL network connection. Transmitter Power Supply (P/N 15124-1) - Acopian Model B24G210M24 Vdc 2.0 Amp Power Supply. Blank Filler Panel (P/N 15738-168) - Blank unit panel for uniform control room appearance when panel includes space for future controllers. Loop Identification Card - Custom printed loop identification for flipdown access door. Up to 5 lines with 24 characters per line can be specified. Permanent Instrument Tag - Stainless steel instrument tag permanently attached to the Moore 353 casing. Two lines with up to 15 characters per line can be specified. 1) x.xx specifies the software’s revision number. This will be defined by Siemens as the latest version. Controllers Model 354N Universal Loop Controller Ordering data Model Number Universal Loop Controller Power Requirements • 120/240 Vac (90-250 Vac), 47-63 Hz Local Faceplate Display • Not Required • Fixed Analog & Digital Displays - Direct Mounted1 • Fixed Analog & Digital Displays - Remote Mounted1 Expander I/O Board • Not Required • Local I/O Expander (T/C, RTD, Frequency, Relay, ...) Option Board A-1 (Remote I/O Comm) • Not Required • LonWorks Protocol Option Board A-2 • Not Required Option Board B-1 (Network Comm) • Not Required • Local Instrument Link (LIL) Removable Configuration Board • Not Required • RTC/CB Modification Options • Not Required • Controller Modified as detailed in order BOM Reserved for Future Use • Reserved for Future Use Design Level • Design Level A Electrical Approval • Not Required • CSA (NRTL) Class I, Div. 2, Groups A, B, C & D • CE + CSA (NRTL) Class I, Div. 2, Groups A, B, C & D2 Order No. 354N■■■■ - ■■■■■■■ ▲▲▲▲ ▲▲▲▲▲▲▲ 1 N D R 2 N 1 N L N N L N T N X N A N J E 1) Required with Lonworks I/O. 2) Check Siemens for latest availability. 2.13 Controllers Model 354N Universal Loop Controller Dimensional drawings Mounting Dimensions 2 Controller and Controller Mounting Tray Dimensions 2.14