Transcript
2-wire series
Model D250 Fisheye door station with Proximity Reader
USER MANUAL
RF CARD
DT607/ID/FE-S1
RF CARD
DT607/ID/FE-S3
RF CARD
DT607/ID/FE-S2
RF CARD
DT607A/ID-S4
RF CARD
RF CARD
DT607/ID/FE-S4
DT607F/ID/FE-S4
• Please read this manual carefully to ensure safe and correct operation • Keep this manual well for future reference
CONTENTS PARTS AND FUNCTIONS...................................................................................... 3 Part Names............................................................................................................. 3 Mounting.................................................................................................................. 4 BASIC FUNCTIONS............................................................................................... 6 Unlock Operations................................................................................................... 6 Fisheye Camera...................................................................................................... 6 External Motion Detection....................................................................................... 6 SETUP INSTRUCTIONS......................................................................................... 7 Functions Setting Up............................................................................................... 7 Setting Door Station Address.................................................................................. 8 Setting Door Station Calling Mode.......................................................................... 8 Setting Camera Resolution.................................................................................... 10 Setting Unlock Mode.............................................................................................. 10 Setting Unlock Time............................................................................................... 11 Setting Nameplate Illumination Mode..................................................................... 11 Setting Night View LED Illumination Mode............................................................. 12 Setting Ring-back Tone.......................................................................................... 12 Setting Image Display Mode.................................................................................. 13 Registering ID Card................................................................................................ 14 WIRING.................................................................................................................. 17 Connecting Electric Lock........................................................................................ 17 Connecting Basic One-to-one................................................................................ 18 Connecting Multi Door Stations.............................................................................. 18 Connecting Multi Monitors...................................................................................... 19 APPENDIX............................................................................................................. 21 Precautions............................................................................................................ 21 Specification........................................................................................................... 21 Cables and Requirments........................................................................................ 22
PARTS AND FUNCTIONS
Parts Surface mounted
[10]
[11]
[1] [9]
[12]
[2] [3]
[8] [7] [6]
[4]
[13] [5]
Flush mounted [14]
[11] [1] [9]
[2]
[12]
[3] [8] [7] [4] [6]
[13]
[5]
[1] Microphone
[5] Nameplate
[10] Rain cover
[2] UNLOCK indicator
[6] Front panel
[11] Mounting hook
[3] Call indicator
[7] Speaker
[12] Connection port
[4] Call button
[8] Night view LED
[13] Screw hole
[9] Camera lens
[14] Mounting box
-3-
PARTS AND FUNCTIONS
Mounting The installation height is suggested to 145~160cm
Surface mounted 1
2 Rain cover Main unit
3 The distance between the top of main unit and rain cover should be not less than 3mm. Rain cover
4
5
≥3mm
Main unit
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
1. Connect the cable 2. Drill holes in the wall to match the size of screw stoppers, then attach the rain cover and main unit to the wall. The distance between the top of main unit and rain cover should be not less than 3mm 3. Install the name plate 4. Attach the front panel to the main unit 5. Use the special screwdriver and the screws to fix the panel
Flush mounted 1
2
3
4
5
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
AcDbMLeader (ACDB_MLEADER_CLASS)
1. Drill a hole in the wall to match the size of mounting box, then install the mounting box 2. Loosen the high screws to install the name plate 3. Connect the cable 4. Attach the front panel to the mounting box,then use the special screwdriver and the screws to fix the panel 5. Finish the installation * The camera angle view of surface mount model may be less than 1700 -4-
PARTS AND FUNCTIONS Terminal description
Lock Control Jumper
1 2 3
+12V GND PIR
PIR Motion Detector Connect Port
SPL S+ L1 L2
Main Connect Port
Lock Control Jumper: To set the type of lock Motion Detector Connect Port: To connect external PIR motion detector Main Connect Port: To connect the bus line and the electric lock • L1,L2: Connect to the bus line, no polarity • PL: External lock power input, connect to the power positive (power +) • S+: Lock power(+) output • S-: Lock power(-) output, connect to the power(-) input of lock (only when using the door station to power the lock
-5-
BASIC FUNCTIONS
Unlock Operations Unlocking with Proximity Fob/Card When registered user fob/card has been shown to the proximity Reader, the UNLOCK indicator lights up, the buzzer sounds, and the electric lock is unlocked • Authorized user fob/card will make one beep sound,and the UNLOCK indicator will lights up • Unauthorized user fob/card will make 3 beep sounds
Fisheye Camera Please note that this function requires the monitor with fisheye function to support.
Standard door station angle
The angle of view is 170 0 Image can be zoomed as well
DT607
170 degree fisheye camera
External Motion Detection The door station is equipped with a terminal to connect external PIR motion detector If motion is detected, the door station will turn security light on
12V GND PIR Motion detector
-6-
SETUP INSTRUCTIONS
Functions Setting Up This section explains the settings of each function,please refer to the following table To perform the settings for the function you want,you should remove front cover. Please refer to the sketch Each setting will be indicated by lighting up of the LED indicators and by the sounding of the buzzer
LED_UNLOCK LED_TALK KEY_SET KEY_4
LED_NAME
KEY_3 KEY_2
RF CARD
KEY_1
Order
Settings
Setting range
Default value
1
Door station address
0~3
0
Standard/Group calling mode
Standard calling mode
High/Low
High
2 3
Door station calling mode Camera resolution
4
Unlock mode
0:opened/1:closed
0:opened
5
Unlock time
01 to 99 seconds
1 seconds
On/Off/Auto
On
On/Off/Auto
Auto
6
7
Nameplate illumination mode Night view LED illumination mode
Ring once 8
Ring tone
Ring continuously
Ring once
No ring tone Alternate switching mode 9
Image display mode
Zoom mode
Alternate switching mode
Full screen mode
-7-
SETUP INSTRUCTIONS
Door Station Address Setting 4 addresses can be assigned. The address can be modified either before or after installation Default address is 0. To change the address, please follow the steps: ID=0, for 1st door station
ID=1, for 2nd door station
ID=2, for 3rd door station
In standby press KEY_SET button once
Press KEY_1 button to set the first door station
UNLOCK Indicator:OFF TALK Indicator:OFF
Press KEY_2 button to set the second door station
Press KEY_3 button to set the third door station
ID=3, for4th door station
Buzzer
Beep+, Beep
Press KEY_4 button to set the fourth door station
UNLOCK Indicator:OFF TALK Indicator:OFF
UNLOCK Indicator:OFF TALK Indicator:OFF
UNLOCK Indicator:OFF TALK Indicator:OFF
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Buzzer
Buzzer
Buzzer
Beep+
Beep,Beep
Beep,Beep,Beep
Beep,Beep,Beep,Beep
• Press KEY_SET button to go into programming mode and change the address of door station by pressing KEY1~4 • The LED_NAME indicator will blink until exit out programming mode • No activity for 10 seconds will exit programming mode automatically • Or press KEY_SET button four times to exit programming mode manually
Setting Door Station Calling Mode There are two calling modes available: Standard calling mode and Group calling mode Please know that the door station supplied in Standard calling mode by default
-8-
SETUP INSTRUCTIONS Each call button will respond different addresses when set in different calling mode
1.Standard calling mode (Address range 01-04 )
Call button A: call the monitor with address 01 Call button B: call the monitor with address 02 RF CARD
RF CARD
A
B A
Call button C: call the monitor with address 03 Call button D: call the monitor with address 04
2.Group calling mode
RF CARD
C B A
RF CARD
Call button A: Call all monitors in group address
D C B A
from 00~15 (one of the monitor should be set to 00) Call button B,C,D: Call all monitors in group address from 16~31 (one of the monitor should be set to 16)
To change this setting, please follow the steps: In standby press KEY_SET button twice
Press KEY_1 button to activate Standard calling mode for door station
Press KEY_1 button again to activate Group calling mode for door station
UNLOCK Indicator:OFF TALK Indicator:ON
UNLOCK Indicator:OFF TALK Indicator:ON
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Buzzer
Buzzer
Beep+, Beep
Beep+
Beep, Beep
Press KEY_1
• If setting mode has not been exited, you can change the calling mode by pressing KEY1 circularly. • The LED_NAME indicator will blink all the time until exit out the setting mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • In this step,press KEY_SET button three times to exit out the setting mode manually.
-9-
SETUP INSTRUCTIONS
Camera Resolution Setting High resolution of the camera is default. To change from High Resolution to Low Resolution, please follow the steps:
In standby press KEY_SET button twice
Press KEY_2 button to set the camera to High resolution
Press KEY_2 button again to set the camera to Low resolution
UNLOCK Indicator:OFF TALK Indicator:ON
UNLOCK Indicator:OFF TALK Indicator:ON
UNLOCK Indicator:OFF TALK Indicator:ON
Buzzer
Buzzer
Buzzer
Beep+, Beep
Beep+
Beep, Beep
Press KEY_2
• If setting mode has not been exited, you can change the camera resolution by pressing KEY2 circularly. • The LED_NAME indicator will blink all the time until exit out the setting mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • In this step,press KEY_SET button three times to exit out the setting mode manually.
Unlock Mode Setting 2 unlock modes are available: Normally Opened and Normally Closed Normally opened is default. To change the setting, please follow the steps: Press KEY_1 button to set the unlock mode to Normally opened
Press KEY_1 button again to set the unlock mode to Normally closed
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Buzzer
Buzzer
In standby press KEY_SET button three times
Beep+, Beep
Beep+
Beep, Beep
Press KEY_1
• If setting mode has not been exited, you can change the unlock mode by pressing KEY1 circularly. • The LED_NAME indicator will blink all the time until exit out the setting mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • In this step,press KEY_SET button twice to exit out the setting mode manually.
-10-
SETUP INSTRUCTIONS
Unlock Time Setting Default unlocking time is 1s. It can be changed to desired time. Available setting range is 1s~99sec. Please, follow the steps: In standby press KEY_SET button three times
Press and hold KEY_2 The time you holding down is the new unlocking time
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Beep+, Beep
Buzzer
Beep,Beep. .
• When entering time delayed setting, the buzzer sound one time every second. • The LED_NAME indicator will blink all the time until exit out the setting mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • In this step,press KEY_SET button twice to exit out the setting mode manually.
Nameplate Illumination Mode Setting There are 3 illumination modes for nameplate indicator, Normally on,Normally off and Auto. Normally on is default, to change the setting, please follow the steps: In standby mode, press KEY_SET button three times.
Press KEY_3 button to set the nameplate illumination mode to Normally on.
Press KEY_3 button again to set the nameplate illumination mode to Normally off.
Press KEY_3 button again and again to set the nameplate illumination mode to Auto.
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Buzzer
Buzzer
Buzzer
Beep+, Beep
Beep+
Beep, Beep
Beep, Beep,Beep
Press KEY_3
• If setting mode has not been exited, you can change the nameplate illumination mode by pressing KEY3 circularly. • The LED_NAME indicator will blink all the time until exit out the setting mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • In this step,press KEY_SET button twice to exit out the setting mode manually.
-11-
SETUP INSTRUCTIONS
Setting Night View LED Illumination Mode There are 3 working modes for night view LED indicator, Normally on,Normally off and Auto. Auto is default, to change the setting, please follow the steps: Press KEY_4 button to set the night view LED mode to Normally on.
Press KEY_4 button again to set the night view LED mode to Normally off.
Press KEY_4 button again and again to set the night view LED mode to Auto.
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:OFF
Buzzer
Buzzer
Buzzer
Buzzer
In standby mode, press KEY_SET button three times.
Beep+, Beep
Beep+
Beep, Beep
Beep, Beep,Beep
Press KEY_4
• If setting mode has not been exited, you can change the night view LED illumination mode by pressing KEY4 circularly. • The LED_NAME indicator will blink all the time until exit out the setting mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • In this step,press KEY_SET button twice to exit out the setting mode manually.
Ring Tone Setting If allow ring-back tone, press the call button to call monitor, a ring-back call tone can be heard from door station. There are 3 ring-back call tones, Ringing one time,Ringing continuously and No ring-back tone. Ringing one time is default, to change the setting, please follow the steps: In standby mode, press KEY_SET button four times.
Press KEY_1 button to set the ring-back call tone ringing one time.
Press KEY_1 button again to set the ring-back call tone ringing continuously.
Press KEY_1 button again and again to close ring-back call tone.
UNLOCK Indicator:ON TALK Indicator:ON
UNLOCK Indicator:ON TALK Indicator:ON
UNLOCK Indicator:ON TALK Indicator:ON
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Buzzer
Buzzer
Buzzer
Beep+, Beep
Beep+
Beep, Beep
Beep, Beep,Beep
Press KEY_1
• If setting mode has not been exited, you can change the ring-back tone by pressing KEY1 circularly. • The LED_NAME indicator will blink all the time until exit out the setting mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • In this step,press KEY_SET button once to exit out the setting mode manually. -12-
en mode in cycle.
SETUP INSTRUCTIONS
Setting Image Display Mode Please know that this setting is only effective for monitors which does not support manual operation for pan-tilt.
When the monitor being called When door station calls monitor,the image will be displayed on screen,there are 3 modes for image displayed, Alternate switching mode,Zoom mode and Full screen mode. Alternate switching mode: when the monitor being called, switch at regular time(5s) between Full screen and Zoom image. Zoom mode: when the monitor being called, the image will be displayed on full screen for 5 seconds, then switch to Zoom image. Full screen mode: when the monitor being called, the image will be always displayed on Full screen. Alternate switching mode is default, to change the setting, please follow the steps: Press KEY_2 button to set the image display mode to Cycle switching.
Press KEY_2 button again to set the image display mode to Zoom mode.
UNLOCK Indicator:ON TALK Indicator:ON
UNLOCK Indicator:ON TALK Indicator:ON
UNLOCK Indicator:ON TALK Indicator:ON
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Buzzer
Buzzer
Buzzer
In standby mode, press KEY_SET button four times.
Beep+, Beep
Beep+
Beep, Beep
Press KEY_2 button again and again to set the image display mode to Full screen.
Beep, Beep,Beep
Press KEY_2
• If setting mode has not been exited, you can change the image display mode by pressing KEY2 circularly. • The LED_NAME indicator will blink all the time until exit out the setting mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • In this step,press KEY_SET button once to exit out the setting mode manually.
When answering the call When answering the call, the image switching reminder can be activated or forbidden. If set to activated mode, the image switching reminder will be different for different image display mode. Alternate switching mode: When answering the call, image switching reminder is not effective. Zoom mode: When answering the call, the image will be displayed on full screen for 5 seconds, then switch to Zoom image to remind to enter talking status. -13-
SETUP INSTRUCTIONS Full screen mode: When answering the call, the image will be displayed on Zoom mode for 5 seconds, then switch to Full screen to remind to enter talking status. If set to forbidden mode, there is no image switching reminder at any image display mode. Activated is default, to change the setting, please follow the steps: In standby mode, press KEY_SET button four times.
Press KEY_3 button to activate image switching when answering the call.
Press KEY_3 button again to forbid image switching when answering the call.
UNLOCK Indicator:ON TALK Indicator:ON
UNLOCK Indicator:ON TALK Indicator:ON
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Buzzer
Buzzer
Beep+, Beep
Beep+
Beep, Beep
Press KEY_3
• If setting mode has not been exited, you can change the image display mode by pressing KEY3 circularly. • The LED_NAME indicator will blink all the time until exit out the setting mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • In this step,press KEY_SET button once to exit out the setting mode manually.
Registering ID Card • Up to 320 user cards can be registered by the door station. • Easy management with LED status and sound hints. • There are two master cards, one MASTER CARD ADD card and one MASTER CARD DELETE card, When registered new master cards, the old master cards are invalid automatically. • Card reading distance is less than 3cm. • The master cards are necessary when you add or delete user cards. Please keep it well for future use. • EM card, 125kHz.
Authorizing master cards: By default,there are two master cards marked MASTER CARD ADD and MASTER CARD DELETE ,but you should know that the master card can be authorized by users at any time. That means any two user cards can be authorized to master cards,When registered new master cards, the old master cards will be invalid automatically. -14-
SETUP INSTRUCTIONS
Press KEY_2 button.
Show the first card to ID card window, set the card of MASTER CARD ADD.
Show the second card to ID card window, set the card of MASTER CARD DELETE.
UNLOCK Indicator:OFF TALK Indicator:OFF
UNLOCK Indicator:Blink one time TALK Indicator:OFF
UNLOCK Indicator:Blink two times TALK Indicator:OFF
UNLOCK Indicator:Blink three times TALK Indicator:OFF
Buzzer
Buzzer
Buzzer
Buzzer
When power on in 10s,press and hold on KEY_SET button for 3s.
Beep+, Beep
Beep+
Beep,Beep
Beep,Beep,Beep
• The LED_NAME indicator will always blink until exit out the master card authorized mode. • If without any operation in 10 seconds, it will exit out setting mode automatically. • It will exit out setting mode automatically after showing these two cards,the UNLOCK&TALK indicator will be turned off.
Switching Access Control: The access can be controlled by door station or DT-ACC,so it’s available to switch the access function. Show the master card of MASTER CARD DELETE again to switch as a door station access control. UNLOCK Indicator:OFF TALK Indicator:OFF
Show the master card of MASTER CARD ADD to ID card window in standby.
Show the master card of MASTER CARD DELETE to ID card window.
UNLOCK Indicator:OFF TALK Indicator:ON
UNLOCK Indicator:ON TALK Indicator:ON
Buzzer
Buzzer
Beep+, Beep
Beep+, Beep
Buzzer
Beep+
Show the master card of MASTER CARD DELETE again to switch to DT-ACC controlled. UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Beep+,Beep
• If without any operation in 10 seconds, it will exit out setting mode automatically. • If current access is controlled by door station, next access switching setting is controlled by DT-ACC.
-15-
SETUP INSTRUCTIONS
Adding User Cards: Show the master card of MASTER CARD ADD to ID card window in standby.
Show user cards to be added in sequence.
Show the master card of MASTER CARD ADD again to exit.
UNLOCK Indicator:OFF TALK Indicator:ON
UNLOCK Indicator:OFF TALK Indicator:Blink one time
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Buzzer
Buzzer
Beep+, Beep
Beep+
Beep, Beep+
• If without any operation in 10 seconds, it will exit out setting mode automatically. • To add user card, the access must be controlled by door station.
Deleting User Cards: Show the master card of MASTER CARD DELETE to ID card window in standby.
Show user cards to be deleted in sequence.
Show the master card of MASTER CARD DELETE again to exit.
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:Blink one time TALK Indicator:OFF
UNLOCK Indicator:OFF TALK Indicator:OFF
Buzzer
Buzzer
Buzzer
Beep+, Beep
Beep+
Beep, Beep+
• .If without any operation in 10 seconds, it will exit out setting mode automatically. • To add user card, the access must be controlled by door station.
Initializing Access (delete all user cards): Show the master card of MASTER CARD DELETE to ID card window in standby.
Show the master card of MASTER CARD ADD to ID card window.
Show the master card of MASTER CARD ADD again, format is activated.
UNLOCK Indicator:ON TALK Indicator:OFF
UNLOCK Indicator:ON TALK Indicator:ON
UNLOCK Indicator:Blink for some time TALK Indicator:Blink for some time
Buzzer
Buzzer
Buzzer
Beep+, Beep
Beep+, Beep
Beep
• If without any operation in 10 seconds, it will exit out setting mode automatically. • To add user card, the access must be controlled by door station. • At step3, the UNLOCK & TALK indicator will blink all time until formatting is finished. • When formatting is finished, UNLOCK & TALK indicator will be turned off and sound “ Beep+ ”, and exit out setting mode automatically. -16-
WIRING
Connecting Electric Lock Door Lock Controlled with Internal Power 1 2 3
1.Electric Power-on-to-unlock type should be used 2.The door lock is limited to 12V, and holding current must be less than 250mA
Jumper position on 2&3
L1
L2
PL
S+
S-
3.The jumper should be placed in position 2 and 3 before connecting 4. Unlocking is not timed from Exit Button(EB)
* EB
LOCK
5.The Unlock Mode must be set to 0 (default)
Door Lock Controlled with Dry Contact 1.The external power supply must be used according to the lock specs
1 2 3
2.The inside relay contact is restricted to 230Vac 1A or 24Vdc 1A 3.The jumper must be taken off before connecting
Take off the jumper
L1
L2
PL
S+
S-
4.Setup the Unlock Mode according to different lock types • Power-on-to-unlock type:Unlock Mode=0 (default)
POWER SUPPLY
• Power-off-to-unlock type:Unlock Mode=1
LOCK
* 2nd lock connection is possible with additional DT-RLC Lock Control Interface
-17-
WIRING
1-Monitor Kit Connection ID=0
AC~
Code=1, DIP6=on
100~240VAC PC6A RF CARD
BUS(IM) BUS(DS)
L1 L2 PL S+ S-
L1 L2
DIP Switches ON
DIP
123456
+
• The door station default is Standard mode. Button will call monitor with User Code 1
Connecting Multiple Door Stations 1st door station ID=0
RF CARD
L1 L2 PL S+ S-
2nd door station ID=1
RF CARD
3rd door station ID=2
4th door station ID=3
RF CARD
L1 L2 PL S+ S-
RF CARD
L1 L2 PL S+ S-
L1 L2 PL S+ S-
To monitors
AC~
100~240VAC A B C D DBC4A1
PC6A
OFF BUS(IM) BUS(DS)
ON
Impedance switch
• Max.4 door stations can be connected to the system • Ensure to set the correct address for each door station. Refer to page 8 for more details about door stations address setting -18-
WIRING
Connecting Multiple Monitors via daisy chain Basic IN-OUT Wiring in Standard Mode
Code=1, DIP6=on (Slave 3)
Code=1, DIP6=off (Slave 2)
• The door station is also compatible with other monitors which are provided by our company. • Please set door station into group calling mode if there is more than 4 monitors in villa(Refer to Page 9) • Distributor is unnecessary in full audio system, and IN-OUT mode is recommended. • For the last monitor connected to the system, DIP6 should set to ON.
Code=1, DIP6=off (Slave 1)
Code=1, DIP6=off (Master) AC~
100~240VAC SCU
PC6A
GSM
TPS
QSW
BUS(IM) BUS(DS)
Optional functional module SCU camera module(max.4) GSM module(mobile phone transfer) TPS module(PBX transfer) QSW image quad splitter module
RF CARD
ID=0 -19-
WIRING Star Topology Wiring With DBC4A1 in Standard Mode
Impedance switch
Code=2,DIP6=on
Code=3,DIP6=on
Code=4,DIP6=on
OFF ON
A B C D
DBC4A1
Code=1,DIP6=on
AC~
100~240VAC
BDU
PC6A
RLC
DBC4A1
BUS(IM) BUS(DS)
Optional functional module BDU bus amplifier module RLC staircase light controller module DBC4A1 2/4 inputs branch distributor
RF CARD
ID=0 • The door station is also compatible with other monitors which are provided by our company. • It can be extended 3 slave monitors for each monitor.(Better use with extra distributor for the extension) -20-
APPENDIX
Precautions • Please clean the unit with soft cotton cloth, don't use the organic impregnant or chemical clean agent. If necessary, please use a little pure water or dilute soap water to clean the dust. • The unit is weather resistant. However do not spray high pressure water on access control keypad directly. Excessive moisture may cause problems with the unit. • You must use the right adaptor which is supplied by the manufacture or approved by the manufacture. • Pay attention to the high voltage inside the products, please refer service only to a trained and qualified professional.
Specification Power supply:
DC 24V
Power consumption:
Standby 0.8W; Working 3W
Camera lens:
Color CMOS, 2.0 Mega pixel 1/2.7’’ fisheye camera,1700 wide angle
Lock Power supply:
12Vdc, 280mA(Internal Power);
Number of relay circuits:
2(the second lock need external device to support)
Mounting:
Surface wall-mount / flush mount
Working temperature:
-20ºC ~ +55ºC
Protection: IP54 Material:
Zinc alloy panel(surface mounted) Stainless steel panel(flush mounted)
Wiring: 2 wires, non-polarity Dimension: 176(H)×90(W)×27(D)mm(surface mounted) 220(H)×119(W)×52(D)mm(flush mounted)
-21-
APPENDIX
Cables and Requirments The maximum distance of the wiring is limited in the DT system. Using different cables may also affect the maximum distance which the system can reach.
Basic IN-OUT Wiring Mode
Cable and distance(unit:m) Cable Usage
B
PC6A
A
RF CARD
-22-
A
B
B
≤2 IM
≤16 IM
Twisted cable 2x0.75mm2
60
100
40
Twisted cable 2x1mm2
80
120
60
APPENDIX Star Topology Wiring Mode With DBC4A1
2 DBC4A1
B
2
C
PC6A
Cable and distance(unit:m)
A
Cable Usage
A
B
C
Twisted cable 2x0.75mm2
60
60
30
Twisted cable 2x1mm2
80
80
40
RF CARD
-23-
The design and specifications can be changed without notice to the user. Right to interpret and copyright of this manual are preserved.