Preview only show first 10 pages with watermark. For full document please download

Model De-1 Front:cutsheet Template.qxd

   EMBED


Share

Transcript

MODEL DE-1 DELAYED EGRESS STATION OUTSTANDING FEATURES          COMPLIES WITH NPFA 101 LIFE SAFETY CODE, BOCA, SBC AND UBC MOUNTED ON DOUBLE GANG STAINLESS STEEL WALLPLATE OPERATES ON 12 OR 24 VOLTS DC 2 SECOND NUISANCE DELAY KEYSWITCH RESET AND RE-LOCK, OPTIONAL AUTO RESET S.P.D.T. INSTANT CONTACTS FOR REMOTE ALARM SIGNAL S.P.D.T. TIMED CONTACTS FOR UN-LOCKING DOOR COUNTDOWN BUZZER AND FLASHING LAMP DURING TIMING MODE LIFETIME WARRANTY ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE P.O. BOX 280 DEER PARK, NY 11729 1 631 586-4220 1 800 645-5538 WWW.ALARMCONTROLS.COM EMAIL [email protected] MODEL DE-1 DELAYED EGRESS STATION DELAYED EGRESS OPERATION THS MICRO-CONTROLLER BASED UNIT WILL PROVIDE AN EFFECTIVE MEANS OF LOCKING AN EXIT DOOR WHILE STILL PROVIDING EGRESS DURING AN EMERGENCY. PUSHING THE TWO INCH SQUARE BUTTON ON THE DE-1 WILL START THE IRREVOCABLE EXIT TIME.THERE IS A TWO SECOND NUISANCE FEATURE REQUIRING THE BUTTON TO BE PUSHED AND HELD BEFORE THE TIMER WILL START, AT THIS TIME, THE ALARM RELAY WILL BE ENERGIZED AND THE SOUNDER AND LIGHT WILL TURN ON. AT THE END OF THE ADJUSTABLE DELAY TIME, (2 TO 30 SEC.), THE LOCK RELAY IS ENERGIZED ALLOWING THE EXIT DOOR TO UN-LOCK. THE ALARM RELAY, LOCK RELAY, SOUNDER AND LIGHT WILL REMAIN ON UNTIL RESET WITH THE MOMENTARY KEYSWITCH.THERE IS AN OPTIONAL AUTO RESET FEATURE WHICH WILL ALLOW THE EXIT DOOR TO RE-LOCK. DURING THE DELAY PERIOD THE SOUNDER AND LIGHT WILL PULSE AT A DEGRADING RATE SPECIFICATIONS INPUT VOLTAGE: 12 TO 24 VDC CURRENT: 200 MA. MAXIMUM DELAY TIME: 2 TO 30 SECONDS, ADJUSTABLE NUISANCE TIMER: 2 SECONDS FIXED OUTPUTS: S.P.D.T. ALARM RELAY, S.P.D.T. LOCK RELAY CONTACT RATING: 5 AMP. @ 35 VDC BUZZER SOUND LEVEL: 85db @ 3 FEET, 2900 HZ ALARM CONTROLS CORPORATION “QUALITY SECURITY EQUIPMENT SINCE 1971” 19 BRANDYWINE DRIVE, P.O. BOX 280, DEER PARK, NEW YORK 1 800 645-5538 631 586-4220 FAX 631 586-6500 EMAIL: [email protected] WWW.ALARMCONTROLS.COM MODEL DE-1 DELAYED EGRESS STATION WIRING INSTRUCTIONS DELAYED EGRESS OPERATION THIS MICRO-CONTROLLER BASED UNIT WILL PROVIDE AN EFFECTIVE MEANS OF LOCKING AN EXIT DOOR WHILE STILL PROVIDING EGRESS DURING AN EMERGENCY. PUSHING THE SQUARE GREEN BUTTON ON THE DE-1 WILL START THE IRREVOCABLE EXIT TIME. THERE IS A TWO SECOND NUISANCE FEATURE REQUIRING THE BUTTON TO BE PUSHED AND HELD BEFORE THE TIMER WILL START. AT THIS TIME, THE ALARM RELAY WILL BE ENERGIZED AND THE SOUNDER AND LIGHT WILL TURN ON. AT THE END OF THE ADJUSTABLE TIME DELAY, (2 TO 30 SEC.), THE LOCK RELAY IS ENERGIZED ALLOWING THE EXIT DOOR TO UN-LOCK. THE ALARM RELAY, LOCK RELAY, SOUNDER AND LIGHT WILL REMAIN ON UNTIL RESET WITH THE KEYSWITCH. THERE IS AN OPTIONAL AUTO RESET FEATURE WHICH WILL ALLOW THE EXIT DOOR TO RE-LOCK. DURING THE DELAY PERIOD THE SOUNDER AND LIGHT WILL PULSE AT A DEGRADING RATE INDICATING WHEN THE EXIT DOOR WILL UN-LOCK. POWER INPUT 12/24 VDC RED LEAD: BLACK LEAD: POSITIVE NEGATIVE LOCK RELAY VIOLET LEAD: GREEN LEAD: BLUE LEAD: NORMALLY-OPEN COMMON NORMALLY-CLOSED ALARM RELAY ORANGE LEAD: WHITE LEAD: YELLOW LEAD: NORMALLY-OPEN COMMON NORMALLY-CLOSED SPECIFICATIONS INPUT VOLTAGE: CURRENT DRAW: DELAY TIME: NUISANCE TIMER: OUTPUTS: CONTACT RATING: BUZZER SOUND LEVEL: LAMP: 12 TO 24 VOLTS DC 200 MILLIAMPERES MAXIMUM TWO TO 30 SECONDS. ADJUSTABLE TWO SECONDS FIXED S.P.D.T. ALARM RELAY & LOCK RELAY 5 AMPERES @ 35 VDC 85db @ 3 FEET, 2900 Hz HIGH BRIGHTNESS LED ALARM CONTROLS CORPORATION 19 BRANDYWINE DRIVE DEER PARK, NEW YORK 11729 800 645-5538