MODEL: R1M-D1 PC Recorders R1M Series
PACKAGE INCLUDES... • PC Recorder Software CD
PC RECORDER (contact output, 32 points) Functions & Features • Industrial recorder on PC • 32-point open collector outputs • Easy system expansion via Modbus RTU • Recorded data exportable to spreadsheet applications • CE marking
175 (6.89)
GENERAL SPECIFICATIONS Connection Power input, transmission: Euro type connector terminal RS-232-C: 9-pin D-sub connector (male) (Lock screw No. 4-40 UNC) I/O: M3 screw terminals or FCN type connector Isolation: RS-232-C or RS-485 to output to power Node address setting: Rotary switch; 1 – F (15 nodes) RUN indicator LED: Green light blinks in normal conditions.
COMMUNICATION 40 (1.57)
Baud rate: 38.4 kbps Communication: Half-duplex, asynchronous, no procedure Protocol: Modbus RTU ■ RS-232-C Standard: Conforms to RS-232-C, EIA Transmission distance: 10 meters max. ■ RS-485 Standard: Conforms to RS-485, EIA Transmission distance: 500 meters max. Transmission media: Shielded twisted-pair cable (CPEV-S 0.9 dia.)
115 (4.53) mm (inch)
MODEL: R1M-D1[1]-[2]/MSR ORDERING INFORMATION • Code number: R1M-D1[1]-[2]/MSR Specify a code from below for each [1] and [2] (e.g. R1M-D1T-M2/MSR)
OUTPUT SPECIFICATIONS
[1] FIELD TERMINAL TYPE T: M3 screw terminals C1: FCN type connector (No CE conformance)
[2] POWER INPUT AC Power M2: 100 – 240 V AC (Operational voltage range 85 – 264 V, 47 – 66 Hz) DC Power R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.)
Output: Open collector, 32 points Commons: All negatives Sampling rate: 50 msec. Rating: 24 V DC @ 50 mA (resistive load) Saturation voltage: 1.6 V DC For use with inductive loads, external protection of contact and noise quenching is recommended.
INSTALLATION
PC Recorder Software Package /MSR: With
Power consumption •AC: Approx. 10 VA •DC: Approx. 7 W Operating temperature: -5 to +60°C (23 to 140°F) Operating humidity: 30 to 90 %RH (non-condensing) Mounting: Surface or DIN rail Weight: 400 g (0.88 lbs)
RELATED PRODUCTS
PERFORMANCE
• Connector terminal block (model: CNT) • Special cable (model: FCN32)
Multi-transmission time: 5 msec. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 2000 V AC @ 1 minute (RS-232-C or RS485 to output to power to ground)
OPTIONS
http://www.m-system.co.jp/
R1M-D1 SPECIFICATIONS
ES-5658 Rev.14 Page 1/5
MODEL: R1M-D1 STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) EMI EN 61000-6-4: 2007 EMS EN 61000-6-2: 2005 Low Voltage Directive (2006/95/EC) EN 61010-1: 2001 Installation Category II Pollution Degree 2 RS-232-C/RS-485 or output to power: Reinforced insulation (300 V) RS-232-C/RS-485 to output: Basic insulation (300 V)
PC RECORDER SOFTWARE PC Recorder Software Package (model: MSRPAC-2010) is included with purchases of this model. Refer to the MSRPAC-2010 data sheet for the contents of the package and the requirements for the PC to be prepared by the user.
EXTERNAL VIEW Power Terminals
RS-485 Connector
RS-232-C 9-pin Connector
Node Address Setting Rotary SW
RUN Indicator LED
Configurator Jack
■ RS-232-C INTERFACE 1
5
6
9
ABBR. PIN NO. BA (SD) 2 BB (RD) 3 AB (SG) 5 CB (CS) 7 CA (RS) 8 1 4 6 9
EXPLANATION OF FUNCTION Transmitted Data Received Data Signal Common Clear to Send Request to Send Not Used. DO NOT connect. Connecting may cause malfunctions.
http://www.m-system.co.jp/
R1M-D1 SPECIFICATIONS
ES-5658 Rev.14 Page 2/5
MODEL: R1M-D1 MODBUS WIRING CONNECTION
RS-232-C
CONNECTOR
R1M
RS-485
T1 T2 T3 T4
RS-485
R1M
R1M
T1 T2 T3 T4
*1
T1 T2 T3 T4
*1
2
FG * *1. Internal terminating resistor is used when the device is at the end of a transmission line. *2. Install shielded cables to all sections and ground them at single point.
CONNECTION DIAGRAM Note: In order to improve EMC performance, bond the FG terminal to ground. Caution: FG terminal is NOT a protective conductor terminal.
ch.1 A1 ch.2 A2
CN1
Output Circuit
■ M3 SCREW TERMINALS ch.1 1 ch.2 2
ch.3 A3
ch.3
ch.4 A4
ch.4
ch.5 A5
ch.5
ch.6 A6
ch.6
ch.7 A7
ch.7
ch.8 A8
ch.8
ch.9 A9
COM (–)
ch.10 A10
ch.9
ch.11 A11
ch.10
ch.12 A12
ch.11
ch.13 A13
ch.12
ch.14 A14
ch.13
ch.15 A15
ch.14
ch.16 A16
ch.15
B1 COM (–) : B16
COM (–)
ch.16 ch.17 ch.18
CN2
ch.17 A1
ch.19
ch.18 A2
ch.20
ch.19 A3
ch.21
ch.20 A4
ch.22
ch.21 A5
ch.23
ch.22 A6
ch.24
ch.23 A7
COM (–)
ch.24 A8
ch.25
ch.25 A9
ch.26
ch.26 A10
ch.27
ch.27 A11
ch.28
ch.28 A12
ch.29
ch.29 A13
ch.30
ch.30 A14
ch.31
ch.31 A15
ch.32
ch.32 A16
COM (–)
COM (–)
B1 : B16
http://www.m-system.co.jp/
3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36
Output Circuit
Input Circuit
Term. Resist.
Power Circuit
D-SUB CONNECTOR
■ FCN TYPE CONNECTOR
RS-232C
Shielded Twisted-pair Cable To Other PC Recorders
T1 T2 T3 T4
+ –
T5 T6 T7
U (+) POWER V (–)
Jumper*
FG
* When the device is located at the end of a transmission line via twisted-pair cable, (when there is no cross-wiring), close across the terminal T2 – T3 with the attached jumper pin (or with a leadwire). When the device is not at the end, remove the jumper pin.
R1M-D1 SPECIFICATIONS
ES-5658 Rev.14 Page 3/5
MODEL: R1M-D1 EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) ■ M3 SCREW TERMINALS
10 (.39)
175 (6.89) 165 (6.50)
15.5 (.61) 3–5 (.20) dia. MTG HOLES T5 T6 T7
105 (4.13)
104 (4.09)
46 (1.81)
T1 T2 T3 T4
DIN RAIL 35 mm wide 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18
14 (.55)
19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 35
3 (.12)
163 (6.42)
40 (1.57)
[6 (.24)]
FOR WALL MOUNT. 6.2 (.24) 36–M3 I/O TERMINALS
■ FCN TYPE CONNECTOR
10 (.39)
175 (6.89)
40 (1.57) 15.5 (.61)
165 (6.50) 3–5 (.20) dia. MTG HOLES T5 T6 T7
A1
B1
105 (4.13)
Connector Pin Assignment
104 (4.09)
46 (1.81)
T1 T2 T3 T4
DIN RAIL 35 mm wide CN1
CN2
14 (.55)
See Caution below
3 (.12)
163 (6.42) 40 (1.57) FCN TYPE I/O CONNECTOR
Caution: DO NOT APPLY EXCESSIVE FORCE onto the connector. The connector may be destroyed.
A16 B16
http://www.m-system.co.jp/
[6 (.24)]
FOR WALL MOUNT.
R1M-D1 SPECIFICATIONS
ES-5658 Rev.14 Page 4/5
MODEL: R1M-D1 SYSTEM CONFIGURATION EXAMPLES
RS-232-C RS-232-C/RS-485 Converter (model: R2K-1) RS-485 TC/DC Inputs (model: R1M-GH)
Contact Inputs (model: R1M-A1)
Contact Outputs (model: R1M-D1)
When the cable distance between the PC and the R1Ms is long, insert an RS-232-C/RS-485 Converter for isolation.
Specifications are subject to change without notice.
http://www.m-system.co.jp/
R1M-D1 SPECIFICATIONS
ES-5658 Rev.14 Page 5/5