Preview only show first 10 pages with watermark. For full document please download

Model: R3-rs8a Remote I/o R3 Series Rtd Input Module

   EMBED


Share

Transcript

MODEL: R3-RS8A Linearization: Standard RUN indicator: Bi-color (red/green) LED; Red when the bus A operates normally; Green when the bus B operates normally; Amber when both buses operate normally. ERR indicator: Bi-color (red/green) LED; Red with the burnout; Green in normal operating conditions. Remote I/O R3 Series RTD INPUT MODULE (8 points, isolated) 27.5 (1.08) INPUT SPECIFICATIONS 130 (5.12) Maximum leadwire resistance: 10 Ω per wire Sensing current: ≤ 1 mA Temperature range RTD 109 (4.29) mm (inch) Pt 100 (JIS ’97, IEC) Pt 100 (JIS ’89) JPt 100 (JIS ’89) RTD MODEL: R3-RS8A[1][2] Pt 100 (JIS ’97, IEC) Pt 100 (JIS ’89) JPt 100 (JIS ’89) ORDERING INFORMATION • Code number: R3-RS8A[1][2] Specify a code from below for each [1], [2] (e.g. R3-RS8AW/CE) Conformance Range °C -20 to +100 -20 to +100 -20 to +100 Conformance Range °F -4 to +212 -4 to +212 -4 to +212 Burnout Values °C × 100 -24000, +32767 -24000, +32767 -23600, +32767 Burnout Values °F × 10 -4000, +16520 -4000, +16520 -3928, +10400 INSTALLATION NO. OF CHANNELS Operating temperature: -10 to +55°C (14 to 131°F) Operating humidity: 30 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R3-BSx) Weight: 250 g (0.55 lbs) 8: 8 [1] COMMUNICATION MODE S: Single W: Dual PERFORMANCE [2] OPTIONS STANDARDS & APPROVALS blank: Without CE /CE: CE marking GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R3-BSx) Input: M3 screw terminals (torque 0.5 N·m) Power supply: Via the base (model: R3-BSx) Screw terminal: Nickel-plated steel Isolation: Input 1 to input 2 to input 3 to input 4 to input 5 to input 6 to input 7 to input 8 to internal power Sensor type: Selectable with the side DIP SW (Independent types selectable per group of 4 channels.) Temperature unit: °C or °F selectable with the side DIP SW Conversion rate: Selectable with the side DIP SW Burnout detection: Upscale or downscale selectable with the side DIP SW http://www.m-system.co.jp/ Conversion accuracy: ±0.2°C or ±0.4°F Conversion rate: 250 msec. or 1 sec. selectable Data range °C: Engineering unit value × 100 (integer) °F: Engineering unit value × 10 (integer) Data allocation: 8 Current consumption: 100 mA Temp. coefficient: ±0.015 %/°C (±0.008 %/°F) Resolution: 0.03°C (0.1°F) Burnout response time: ≤ 2 sec. Insulation resistance: ≥ 100 MΩ with 500 V DC Dielectric strength: 1000 V AC @ 1 minute (input 1 to input 2 to input 3 to input 4 to input 5 to input 6 to input 7 to input 8 to internal power) 2000 V AC @ 1 minute (power input to FG; isolated on the power supply module) STANDARDS & APPROVALS CE conformity: EMC Directive (2004/108/EC) R3-RS8A SPECIFICATIONS ES-8407 Rev.2 Page 1/4 MODEL: R3-RS8A EMI EN 61000-6-4: 2007 EMS EN 61000-6-2: 2005 EXTERNAL VIEW ■ SIDE VIEW ■ FRONT VIEW RUN LED 15 ERR LED 16 17 18 SW1 1 2 3 4 5 6 7 8 SW2 1 2 3 4 5 6 7 8 ON Input 1-4 (SW1) or Input 5-8 (SW2) 19 SW3 RTD 1 2 3 4 ON 20 Burnout Temp. Unit Conv. Rate 21 22 23 24 25 26 ON 27 28 1 2 3 4 5 6 7 8 9 10 11 12 13 14 EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) 27.5 (1.08) 109 (4.29) POSITIONING GUIDE 16 17 18 130 (5.12) 19 20 21 22 23 24 25 26 27 28 http://www.m-system.co.jp/ 1 2 3 4 5 6 7 28–M3 SCREW 8 9 10 11 12 6.2 (.24) 15 13 14 TERMINAL COVER R3-RS8A SPECIFICATIONS ES-8407 Rev.2 Page 2/4 MODEL: R3-RS8A SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM RUN LED ERR LED DIP SW Input Circuit INPUT 1 A 4 B US CO NNE CTOR RTD B 5 13 B 6 A 1 B 2 B 3 Input Circuit RTD INPUT 2 A 7 B 8 B 9 A 10 B 11 B 12 A 15 B 16 B 17 A 18 B 19 B 20 A 21 B 22 B 23 27 28 Input Circuit RTD INPUT 8 14 Input Circuit RTD INPUT 7 INTERNAL POWER Input Circuit RTD INPUT 6 BUS B* Input Circuit RTD INPUT 5 BUS A Input Circuit RTD INPUT 4 Control Circuit Input Circuit RTD INPUT 3 Communication Circuit A 24 B 25 B 26 *For dual redundant communication. • Unused Input Channels Close across the unused input terminals with a resistor as shown below and set the DIP switch for an RTD. The resistance value must match the RTD type (100 Ω for Pt 100). INPUT 1 INPUT 2 INPUT 3 INPUT 4 1 4 7 10 2 5 8 11 3 6 9 12 INPUT 5 INPUT 6 INPUT 7 INPUT 8 15 18 21 24 16 19 22 25 17 20 23 26 http://www.m-system.co.jp/ Unused channels left open are equal to the burnout, which turns the red ERR LED on and sets a burnout flag at the PLC or the host device. Unused channels can be specified and set so on the PC Configurator Software (model: R3CON) without needing to connect resistors at the field terminals. R3-RS8A SPECIFICATIONS ES-8407 Rev.2 Page 3/4 MODEL: R3-RS8A Specifications are subject to change without notice. http://www.m-system.co.jp/ R3-RS8A SPECIFICATIONS ES-8407 Rev.2 Page 4/4