Tripp Lite 1111 West 35th Street Chicago, IL 60609 USA Telephone: +(773) 869 1234 E-mail:
[email protected]
Model #: SUINT1000RTXL2UA SmartOnline UPS System - True online power for mission critical applications Highlights 1000VA online, double conversion 2U rack/tower UPS Zero transfer time, on-line, double-conversion and economy-mode operation supported HID-compliant USB and enhanced serial communications ports with SNMPWEBCARD accessory slot Maintains 200/208/220/230/240V +/-2% output during overvoltages to 277V and brownouts as low as 130V 6 outlets (IEC-320 C13) Fault tolerant auto-bypass 2 year warranty
Description 1000VA online, double-conversion UPS system for critical server, network and telecommunications equipment. 2U rackmount form factor with an installed depth of only 13.5 in (34.3 cm). Expandable battery runtime with optional external battery packs: BP24V15RT2U, BP24V28-2U (maximum of 1 per UPS) or BP24V70-3U (multiple battery packs can be daisy-chained). Full-time sine wave 200, 208, 220, 230 or 240V +/-2% output. Uninterruptible Power Supply (UPS) continuously converts raw incoming AC power to DC, then re-converts output back to completely regulated, filtered AC output. Corrects brownouts as low as 130V and overvoltages as high as 275V without draining battery power. IEC-320-C14 inlet input connection; IEC-320-C13 output receptacles. Network-grade AC surge and noise suppression. Zero transfer time between AC and battery operation. Highly efficient operation in optional Economy Mode setting, saving BTU heat output and energy costs. Network management interfaces support simultaneous communications via USB port, DB9 serial port and SNMPWEBCARD slot. HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X. Supports simultaneous detailed monitoring of equipment load levels, self-test data and utility power conditions via all 3 communications interfaces. Includes PowerAlert monitoring software and complete cabling. Emergency Power Off (EPO) interface. 3-stage metered current monitoring and battery charge status LEDs. LED display panel easily rotates for more convenient viewing in rackmount or tower configurations. Data-line surge suppression for dialup, DSL or Ethernet network connection. Utility power and voltage regulation LEDs. Audible alarm. Self-test. Fault-tolerant auto bypass mode. 4-post rackmount accessories included; optional 2-9USTAND tower stand kit and 2POSTRMKITWM 2-post rack & wall-mount accessories available. Field-replaceable, hot-swappable internal batteries and external battery packs. Attractive all-black color scheme. 2-year warranty; extended warranty and service contracts available. Applications Ideal for protection of critical equipment in server rooms, internetworking closets and telecommunications systems in rackmount or tower applications. Common applications include corporate or departmental servers, workstations, hubs, routers, bridges, CAD/CAM workstations, concentrators, IP telephony and traditional PBX switching systems. Package Includes SUINT1000RTXL2Ua Rack/Tower UPS System PowerAlert Software and Cabling
4-Post Rackmount Installation Hardware and Adjustable-Depth Mounting Rails Warranty Information and Owner's Manual
Features True online, double-conversion power conditioning offers network-grade pure sine wave AC power for critical fileservers, internetworking equipment and other sensitive electronics Maintains output within 2% of selectable 200/208/220/230/240V at 50/60Hz (+/-0.05Hz) Neutralizes hard-to-solve problems like frequency variations, fast electrical impulses, harmonics and other power problems not addressed by other UPS types Zero transfer time, on-line, double-conversion and economy-mode operation supported Versatile rack/tower format requires only 2 rack spaces (2U) in rackmount applications Maintains AC output at near perfect levels even during extended-duration brownouts as low as 130V and overvoltages to 275V without using battery power. (For loads under 70%, brownout support extends to 130V; for loads over 70%, brownout support extends to 160V) During power failures, internal batteries support connected equipment for 12 minutes at half load (500VA / 400W) and 4 minutes at full load (1000VA / 800W) Battery backup runtime is expandable with the addition of external 2U or 3U rack/tower battery packs (Part Number BP24V15RT2U, BP24V28-2U or BP24V70-3U) Built-in USB port, DB9 serial port and SNMPWEBCARD slot are simultaneously addressable and support comprehensive network management features; USB and DB9 serial cables included Included PowerAlert software offers unattended shutdown, remote monitoring and control of UPS system and connected equipment Optional SNMPWEBCARD enables remote monitoring and UPS control via SNMP, Web browser or telnet (Part Number: SNMPWEBCARD) HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X Includes 6 UPS supported IEC-320-C13 output receptacles and two C13 to C14 interconnection cables (additional interconnection cables available - Part Number P004-006) Fault-tolerant auto bypass maintains continuous utility output to connected equipment, even in cases where the UPS is overloaded or suffers an internal failure that requires service Compatible with Tripp Lite's WatchDog software Front panel LEDs and audible alarm offer notification of power conditions and full UPS status information Optional tower stands allow vertical tower configuration (Part Number 2-9USTAND) Built-in Emergency Power Off (EPO) interface with cable From the same product family as Tripp Lite's SmartOnline SU2200RT2U, named "Editor's Choice" by PC Magazine 2-year manufacturer's product warranty
Specifications SYSTEM OVERVIEW Voltage compatibility
200, 208, 220, 230, 240V (selectable)
Frequency compatibility
50/60 Hz auto-sensing
OUTPUT Output VA
1000
Output watts
800
Output nominal voltage
200, 208, 220, 230, 240V (selectable)
Output voltage regulation
Full time sine wave output within 2% of selected nominal, 5% max THD
Output frequency regulation
Output locked to 50/60Hz +/-0.05Hz
Outlet quantity / type
6 IEC-320-C13
Overload protection
8A input breaker
INPUT
Maximum input amps
5.1 (200V)/ 4.9 (208V)/ 4.6 (220V)/ 4.4 (230V)/ 4.2A (240V) max
Input connection type
IEC-320-C14 inlet
Input cord length
Unit is packed with two IEC-320-C14 to C13 interconnection cables (6 ft / 1.8 m and 10 ft / 3 m). Additional 6 ft / 1.8 m interconnection cables available - Part Number P004-006.
Recommended Electrical Service
Input must be capable of providing 5 amps at 200-240V AC nominal levels when used to full capacity
BATTERY Full load runtime
Internal batteries = 4 min. (1000VA)
Half load runtime
Internal batteries = 12 min. (500VA)
Expandable battery runtime
Extended runtime available with optional BP24V15RT2U, BP24V28-2U (limit of one per UPS) or BP24V70-3U (multi-pack compatible) external battery packs
DC system voltage
24V DC
Typical battery lifespan
3-6 years typical
Battery recharge rate
Recharges internal batteries to 80% in 6 hours or less
Replacement Battery Cartridge
RBC92-2U
VOLTAGE REGULATION Voltage regulation description
Online, double-conversion process gives this UPS system the ability to maintain output voltage within +/-2% of selected nominal voltage at all times
Overvoltage correction
Maintains continuous operation without using battery power during overvoltage conditions as high as 275V AC, decreasing output to within +/-2% of selected nominal voltage
Brownout correction
Maintains continuous operation without using battery power during brownout / undervoltage conditions as low as 130V AC, increasing output to within +/-2% of selected nominal voltage (brownout correction goes as low as 160V for loads above 70%)
Severe brownout correction
At load levels less than 70% (under 700VA / 560 watts), UPS maintains continuous output during undervoltages to 130V AC, increasing output within 2% of selected nominal
LEDS ALARMS & SWITCHES Front panel LEDs
LED STATUS DISPLAY: line power (green), online (green), bypass (yellow), on battery (green), overload (red), battery low (yellow) - 4 LED LOAD / BATTERY LEVEL DISPLAY (100%, 75%, 50%, 25%). LED display panel rotates for more convenient viewing in rackmount or tower configurations.
Alarms
Multi-function audible alarm uses distinctive patterns to notify user of operating conditions: backup operation (2 seconds on / 0.5 seconds off), low battery warning (1.25 seconds on / 0.5 seconds off), overload (sounds continuously), UPS fault (4.2 seconds on / 1 second off), input voltage out of frequency (2.1 seconds on / 0.14 seconds off) and high input voltage (2.1 seconds on 0.07 seconds off)
Switches
Includes power off/on switch to enable system turn-on (press ON switch), UPS battery test (press ON switch during normal AC operation), buzzer silence (press ON switch during battery operation) and OFF (press OFF switch) - all switch functions require that the switch be pressed and held for longer than 2 seconds, but less than 4 seconds
SURGE / NOISE SUPPRESSION AC surge suppression
1225 joules
AC suppression response time
Instantaneous
Dataline suppression
Set of 8-wire RJ-style interface jacks offer surge suppression for network ethernet or TEL/DSL connection. Pins 1,2,3 and 6 offer ethernet protection starting at 7.5V and the center two wires, pins 4 & 5, offer TEL/DSL line suppression starting at 260V
EMI / RFI AC noise suppression
Yes
PHYSICAL Shipping weight (lbs)
40.3
Shipping weight (kg)
18.3
Shipping Dimensions (HWD/in)
8.75 x 23.75 x 20.25
Shipping Dimensions (HWD/cm)
22.2 x 60.3 x 51.4
Unit weight (lbs)
28
Unit weight (kg)
12.7
Unit Dimensions (HWD/in)
3.5 x 17.5 x 13.5
Unit Dimensions (HWD/cm)
8.9 x 44.5 x 34.3
Material of construction
Steel housing
Form factors supported
Rack (2U), tower with optional 2-9USTAND tower stand kit
Cooling method
Built-in cooling fan
Battery Access
User-replaceable, hot-swappable batteries
ENVIRONMENTAL Relative Humidity
0 to 95%, non-condensing
Storage Temperature
+5 to +122 degrees Fahrenheit
Operating Temperature
+32 to +104 degrees Fahrenheit
Line mode BTU/hr. (Max.)
442.8
Battery mode BTU/hr. (Max.)
442.8
COMMUNICATIONS Network monitoring port
Includes USB port and DB9 serial port (RS-232 or contact closure). HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X.
Software and cabling included
Includes PowerAlert software CD-ROM and complete cabling
SNMP compatibility
Includes slot for optional SNMPWEBCARD accessory
WatchDog compatibility
Compatible with Tripp Lite's Watchdog software to restore operation to locked equipment through automatic soft reboot of application / OS or hard power off/on reboot of connected equipment - ideal for unattended kiosk applications
LINE / BATTERY TRANSFER Transfer time from line power to battery mode
Zero transfer time, online UPS continuously converts incoming AC to DC, then back to AC. When commercial power is interrupted, UPS maintains continuous pure sine wave output from battery reserves with absolutely no disruption in output AC power.
Low voltage transfer to battery power
Maintains continuous operation during undervoltages as low as 130V (160V at load levels over 70%). Below the switchover point, output is supported from battery-derived AC power.
High voltage transfer to battery power
Maintains continuous operation without using battery power during overvoltages to 275V. Above the switchover point, output is supported from battery-derived AC power.
SPECIAL FEATURES EPO port
Supports "Emergency Power Off" via dedicated built-in EPO jack
Cold Start
Inverter can be "cold started" to enable temporary AC output during a power failure
Appearance
All-metal black housing with black plastic front panel
BATTERY PACK ACCESSORY (optional) Battery Pack Accessory (optional)
BP24V15RT2U, BP24V28-2U (limit of one per UPS) or BP24V70-3U (multi-pack compatible) external battery packs
CERTIFICATIONS Certifications
Tested to CE, SASO, RoHS
WARRANTY Product Warranty Period
2 Years
Related Items External Battery Packs BP24V28-2U
BP24V28-2U - External Battery Pack for UPS System
Qty: [optional]
BP24V70-3U
BP24V70-3U - External Battery Pack for UPS System
Qty: [optional]
BP24V15RT2U
BP24V15RT2U - External Battery Pack for UPS System
Qty: [optional]
More information, including related products, owner's manuals, and additional technical specifications, can be found online at www.tripplite.com/en/products/model.cfm?txtModelID=3983.