Transcript
Model TC8116
8 or 16 Channel Multi-Interface Fiber Optic Multiplexer • Mix or Match Field-Interchangeable Interfaces: RS-232, RS-422, RS-485, TTL, & Dry Contact Relays • Data Rates up to 38.4 Kbps* • Built-In Power Redundancy • Optional Optical Redundancy • Local Dry Contact Relay Alarm • Built-In Test Signal Generator
TC8116S Standalone/Wallmount Unit
• Local & Remote Loopback • Multimode or Single Mode (850/1300/1550nm) • Hardened Temperature Version (optional)
TC8116R PC Card Unit with 1U High Card Cage Note - Front panels/LEDs may differ depending upon electrical interface configuration.
T
he TC8116 is an 8 or 16 Channel fiber optic multiplexer with interchangeable interfaces and built-in power redundancy. Optic redundancy is optional. It supports data rates up to 38.4 Kbps.* Distances up to 80 Km are possible. The TC8116 is available in four configurations: • 8-Channel Async • 8-Channel Sync or Async w/Control • 16-Channel Async • 16-Channel Sync or Async w/Control Interfaces include RS-232, RS-422, TTL, RS-485 and Dry Contact Relay. Synchronous versions must be RS-232. Electrical interfaces are modular and interchangeable in 4-channel increments at any time-before or after installation. Because different interfaces can be mixed in 4-channel increments, a wide variety of interface combinations are available. Diagnostics are extensive and include DIP switches for Local & Remote Loopback, a Test Signal Generator, an Electrical Signal Polarity Inverter, and other application configuration switches. Each unit also provides multiple LEDs for Alarm, Power, Vcc, Optic Signal Status, and Tx & Rx LEDs for each channel.
Applications The TC8116 Fiber Optic Multiplexer provides a flexible, inexpensive method for connecting async/sync terminals, printers, and status collecting devices. It is also used in harsh environments where EMI/RFI interference, ground loops and lightning conditions may exist.
The built-in test signal generator verifies both device and fiber optic link operation. No other test equipment is required for link and device verification. The TC8116 is compatible with all types and sizes of multimode (850/1300nm) or single mode (1300/1550nm) fiber optic cable. Fiber optic connectors are ST or FC. Electrical connectors are RJ-11. Power is 12VDC (standard) or 24VDC, -48VDC, or 115/230VAC with an external power cube. A hardened temperature version (-20°C to 70°C), Model TC8116T, is also available. *Contact factory for higher requirements/availability
TC Communications, Inc. 17881 Cartwright Rd. Irvine, CA 92614 U.S.A. Tel: (949) 852-1972, Fax: (949) 852-1948 Sales: (800) 569-4736 Web Site: www.tccomm.com E-mail:
[email protected]
TC8116
TC8116
RS-485
RS-485
Server
SCADA HOST
RS-232
RTU/PLC
RS-232
Up to 80km, Single Mode Multimode or Single Mode Fiber Optic Cables
Dry Contact Detectors TC1900
Dry Contact Detectors
RS-232
RS-232
TC1900
2-wire Telephone
2-wire Telephone
Typical Point-to-Point Application Using TC8116 Multi-Interface Fiber Optic Multiplexers
RS-232 Virtual Connection
RS-422/485 Virtual Connection
(connect two Async, Async w/Control, or Sync devices) To User’s Device
TC8116 RJ-11 Tx Data Rx Data
RTS (or Tx CLK) CTS (or Rx CLK) FRAME GND SIGNAL GND
Fiber Cable
5
TC8116 RJ-11 5
4
4
3
3
2
2
1
1
6
6
Data Rates (per channel)* ..................................up to 38.4 Kbps
Channel Capacity Async ........................................8 or 16 Sync (RS-232 only) ...................8 or 16
Optical Transmitter..........................LED/ELED Receiver...............................PIN Diode Wavelength ................................850/1300nm MM ...............................1300/1550nm SM Fiber Optic Connectors ..................................ST, Optional FC Loss Budget* - 850/1300/1550nm Multimode @ 62.5/125μm .........15dB Single Mode @ 9/125μm...........20dB
Visual Indicators Channel Status (each ch.) .........Tx, Rx System.............PWR A, PWR B, VccA, .........................................VccB, ALM Optic .......SYNC, RxA, RxB, USE RxA, ...USE RxB, OPTIC TxB, OPTIC RxB
System 9
Bit Error Rate ............1 in 10 or better
Tx Data
To User’s Device
To User’s Device
Rx Data
(connect two Async devices) TC8116 RJ-11
Fiber Cable
TC8116 RJ-11
To User’s Device
(Send Data) SD 2
2 SD (Send Data)
(Send Data) SD 5
5 SD (Send Data)
RTS (or Tx CLK)
(Receive Data) RD 3
3 RD (Receive Data)
CTS (or Rx CLK)
(Receive Data) RD 4
4 RD (Receive Data)
FRAME GND SIGNAL GND
FRAME GND 1
1 FRAME GND
SIGNAL GND 6
6 SIGNAL GND
Electrical
®
Connector ......................RJ11 Female Interface (standard) ................RS-232 Interface (optional)............................... TTL, 2 or 4-wire RS-485, RS-422 and Dry Contact Relay, or any combination*
Alarm Dry Contact...................Normal OPEN
Power Standard ..................12VDC @400mA Optional ...............24VDC, -48VDC, or .........115/230VAC w/ ext power cube
Temperature Operating ......................-10°C to 50°C Hi-Temp (optional).........-20°C to 70°C Storage .........................-40°C to 90°C Humidity ............95% non-condensing
Physical (Standalone Unit) Height..........................(6.71 cm) 2.64" Width.........................(18.13 cm) 7.14" Depth.........................(24.89 cm) 9.80" Weight...........................(1.36 kg) 3 lbs *Contact factory for higher requirements/availabilityt
Note - Information contained in this data sheet is subject to change without prior notice. 010B
#1045959
TC Communications, Inc. 17881 Cartwright Road Irvine, CA 92614 U.S.A. Factory Tel: (949) 852-1972 Fax: (949) 852-1948 Sales Office U.S.A. Domestic International (800) 569-4736 (949) 852-1973 Web Site: www.tccomm.com E-mail:
[email protected] 8/09