Transcript
8000HO04146 10/2004 North Andover, MA USA
Data Bulletin
MODICON® COMPACT™ ASBDAP208 RELAY OUTPUT MODULE General Description
The ASBDAP208 is a eight point relay output module. It utilizes logic signals within the controller to activate eight individually isolated, normally open relay contacts. Source voltage for any output load may be 24…154VDC or 24…250VAC. The ASBDAP208 module supports up to 2A continuous (4A instantaneous) at 120/230VAC or 24VDC, up to 1A continuous (0.6A L/R = 20ms) at 60VDC, and up to 0.3A continuous (0.15A L/R = 3ms) at 140VDC. Note: L is load inductance in henries and R is resistance in ohms. This module requires power from an external 24VDC source to support the relay driver (even if all the outputs use AC power). The ASBDAP208 can be installed in any slot in any ASHDTA20x backplane. It operates off the 5V supply voltage provided through a bus connection at the back of the module, along with a user-supplied 24VDC external power source. The ASBDAP208 has nine LED's. One green LED opposite terminal screw 1 indicates the presence of relay coil voltage when ON. Eight red LED's opposite terminal screws 3, 5, 7, 9, 14, 16, 18 and 20 indicate when ON that the relay coils are energized at outputs 1…8, respectively and suggest that the contact is closed and the load is energized. These LED's are in parallel with the coils, not the load. Wiring Diagram and Simplified Schematic for Output Module:
Backplanes are ordered separately. ASHDTA200 ASHDTA201 ASHDTA202
5 slots, primary (CPU) 5 slots 2 slots
8000DB04146
Modicon Compact ASBDAP208 Relay Output Module Top of Cabinet
Specifications 100 mm (3.9 in)
130 mm (5.07 in)
127 mm (5 in)
130 mm (5.07 in)
130 mm (5.07 in)
Module Type
8 Relay outputs
Output Voltage Ranges
24 … 154VDC, 24 … 250VAC
Operating Mode
Normally OPEN
Response Time (in ms)
10 ms (typical)
Wetting Current
5 mA for closed contacts
Leakage
1 mA
Internal Protective Circuitry
68Ω + 15nF in parallel with each contact
Overload Protection
Should be provided externally
Channel to Bus Isolation
500 V
Bus Current Required
<60 mA typical
Power Dissipation
2.0 W
Storage Temperature
-40 to +85 degrees C
Operating Temperature
0 to 60 degrees C
Relative Humidity
0 … 93% Non-condensing @ 60 degrees C
Weight
0.52 lb (240 g)
Electromagnetic Susceptibility
27 … 500 MHz, 10 V/m (Radiated)
Agency Approvals
UL508, CSA22.2 No.142, FM Class 1 Div 2, VDE 0160
Software Support
Concept™, ProWORX®
IO Map
1 output word
External Power Current
150 mA max @ 24VDC
127 mm (5 in)
130 mm (5.07 in)
Schneider Electric USA One High Street North Andover, MA 01845-2699 1-800-468-5342 For detailed technical documentation visit: www.us.telemecanique.com
This document, and the information contained herein, is to be used exclusively by system integrators and consulting engineers for the sole purpose of specifying Schneider Electric products or for submitting related documentation in support of engineering project proposals. This information is not intended for use in system design, implementation or installation. No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material. © 2004 Schneider Electric All Rights Reserved
2