Preview only show first 10 pages with watermark. For full document please download

Modular Chassis Led High-bay - Precision

   EMBED


Share

Transcript

QHC Modular Chassis LED High-Bay Product Information Project Name Type Catalog Number Date SPECIFICATIONS Features • • • • • • • • • • • • Single 135W fixture directly replaces a 400W HID and equivalent systems. Modular design allows multiple chassis configurations for higher wattage applications. Ideal one-for-one replacement of conventional HID high-bay systems. IP66 applications standard, with sensor fixture is IP65 rated. Provides controlled uniform light distribution with acrylic optics without color shift. Aisle optics deliver superior vertical illumination. Long-life LEDs at L95 (95% lumen maintenance) at 60,000 hours reduce life cycle maintenance costs. Choice of four lumen packages and dimming option available. Rigid durable housing & solid state light engine are resistant to vibration. Up to 114 lumens per watt. Simple three step installation: hang gripple, snap gripple hook hangers to fixture & plug-in/wire fixture. Made In USA. Meets ARRA & Buy American requirements. Construction • • • • • • • • Lightweight cast aluminum post powder coated housing Integral thermistor circuit prevents over heating of LED system Modular LED light engine. Certain airborne contaminants can diminish integrity of acrylic. Consult factory for chemical compatibility. Replaceable driver door allows for quick driver maintenance Optional integral sensor provides enhanced energy savings Optional cast aluminum top box for power connections Weight: 19 lbs. Certifications • • • • • Application Electrical • • • • • • • • • CSA listed for U.S. & Canada. Tested to UL 1598 & UL 8750 standards. Luminaires bear appropriate listing labels. Adheres to LM79, LM80 and TM21 industry standards. DesignLights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org. • Suitable for use with most wired or wireless lighting control systems • Target opportunities include: • Manufacturing • Freezers • Warehouses • Storage • Shipping • High-Bay • Outdoor • Low-Bay Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max) Frequency: 50/60 Hz Nom. (47-63 Hz Min/Max) Power Factor: >0.90 @ full load, 100V through 277V Inrush Current: < 65 Amps max @ 230 VAC, cold start 25ºC (135W) Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Temperature (110º) & Short Circuit with self-recovery Compliant to FCC Part 15 requirements for EMI/RFI emissions NEC/CEC compliant ballast disconnect is standard. Standard surge protection: ANSI Std. C62.41.2 Category A (10 kV) Warranty • Five-year warranty. (Terms and Conditions Apply) CERTIFICATION IP65 IP65 CERTIFIED CERTIFIED LED Product Partner ORDERING INFORMATION – MODEL QHC LED High-Bay VOLTAGE – DRIVER CURRENT 36C 36 Chip1 700 700mA 48C 48 Chip1 Board UL 120-277 VAC 1 347 347 VAC 480 480 VAC – QTY OF LED CHIPS Board 60C 60 Chip 2 Board 1 – – OPTICS AAO Asymmetrical Aisle Optics OAO Open Area COLOR TEMP 51K 5100 120C 120 Chip3 Board 180C 180 Chip3 FOOTNOTES EXAMPLE QHC-UL-60C-700-51K-AAO-10GYSH IP65 CERTIFIED – Board Non DLC with AAO & NAO optics. 2 Non DLC with NAO optics. 3 Non DLC. 4 HBA only. IP65 rated. 5 Sensor programming module sold separately, FSIR-100. 6 Contact factory for additional cord & mounting options. Page 1/6 - Revised 09/30/14 Optics LBO Low-Bay Optics NAO Narrow Aisle Optics1 – OCC SENSOR – CORD PLUG 6 WH Wet Location C8 8' Cord, WL Wet Location C8/ 8' Cord L715 & Plug High-Bay Sensor4 Low-Bay Sensor4 DH-WH Digital Dimming, Wet Location High-Bay Sensor, WS5 DH-WL Digital Dimming, Wet Location Low-Bay Sensor, WS5 No Plug (L7-15P) C8/515 8' Cord & Plug (515P) PQC15 15' Cord/ OTHER 10GYSH 10' Gripple Y SnapHook Hangers QTB QHC Quick Top Box for Power Connectors JP Job Pack Quick Connect DB-WH Digital Bi-Level, Wet Location High-Bay Sensor, HBA DB-WL Digital Bi-Level, Wet Location Low-Bay Sensor, HBA © 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com QHC Modular Chassis LED High-Bay PHOTOMETRIC DATA - AAO DISTRIBUTION Test: L09124201 Test Date: 09/20/12 PHOTOMETRIC DATA: QHC-UL-60C-700-51K-AAO All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA INDOOR CANDELA PLOT ZONAL LUMEN SUMMARY 90 QHC-UL-60C-700-51K-AAO LED150W-053-C2800-M-D 1.00 LED 12484 132 Suspended N.A. 0° = 0.92 90° = 0.60 Length: 0.69 Width: 0.69 Height: 0.00 RCR 50 119 104 93 83 76 69 64 59 55 51 48 10 119 97 81 70 62 55 50 45 42 38 36 70 116 106 98 91 84 79 74 69 65 62 58 25 44 59 81 96 100 70 60 7835 AVG. LUMINANCE (Candela/Sq. M.) 50 10 20 30 0.0 40 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ 70 30 119 100 87 76 68 61 56 51 47 44 41 %Fixt N.A. N.A. N.A. N.A. N.A. N.A. 5224 80 70 119 109 101 93 87 81 76 71 67 63 60 %Lamp 3105 5504 7318 10101 11956 12483 80 COEFFICIENTS OF UTILIZATION (%) RC Lumens 0-20 0-30 0-40 0-60 0-80 0-90 2612 10447 0 RW 0 1 2 3 4 5 6 7 8 9 10 Zone Average Luminance Angle Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet 50 116 102 91 82 74 68 63 58 54 50 47 50 30 116 98 85 75 67 61 55 51 47 43 40 10 116 95 80 70 61 55 50 45 42 38 36 50 111 98 88 79 72 66 61 57 53 49 46 30 111 95 83 73 66 59 54 50 46 43 40 0 10 111 92 78 68 61 54 49 45 41 38 36 0 100 84 73 64 57 51 47 43 39 36 34 25 45 0 10446 10446 10446 5 10138 10022 9837 10 9318 9923 9817 15 8262 9429 9112 20 7830 8966 8073 25 6801 7615 5900 30 6121 6777 4604 35 5038 5283 2684 40 4239 3742 2334 45 3516 3162 1388 55 2924 2076 956 65 1802 1224 682 75 495 703 544 85 219 326 246 65 90 10446 9609 9170 7611 5873 3381 2210 1054 882 824 729 657 464 272 10446 9497 8893 6594 4074 2050 1494 915 833 749 717 592 407 284 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance OPERATING ENVIRONMENT Proposed System Min Temp Max Temp QHC-UL-36C -30°C/-22°F 45°C/113°F QHC-UL-48C -30°C/-22°F 45°C/113°F QHC-UL-60C -30°C/-22°F 45°C/113°F QHC-UL-120C -30°C/-22°F 45°C/113°F QHC-UL-180C -30°C/-22°F 45°C/113°F Application Notes 1. Application temperatures are provided to ensure the longevity and performance of the driver and LEDs. 2. Results are based off the In-Situ Temperature Measurement Test (ISTMT) along with the drivers' temperature and life curves. 3. Precision-Paragon [P2]'s 5 year warranty assumes operation at the maximum ambient temperature range. 4. Must mount fixture a minimum of 24" below ceiling. LUMEN PACKAGE OPTIONS - AAO DISTRIBUTION Proposed System Light Source Quantity & Type CRI CCT Lumens Per Fixture Input Watts Lumens Per Watt QHC-UL-36C 1 QHC 87W 70 5100K 7,547 87 87 QHC-UL-48C 1 QHC 115W 70 5100K 10,357 115 90 QHC-UL-60C 1 QHC 135W 70 5100K 12,483 131 95 QHC-UL-120C 1 QHC 270W 70 5100K 24,966 262 95 QHC-UL-180C 1 QHC 405W 70 5100K 37,449 393 95 *Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards. Page 2/6 - Revised 09/30/14 © 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com QHC Modular Chassis LED High-Bay PHOTOMETRIC DATA - OAO DISTRIBUTION Test: L02134304R01 Test Date: 03/07/13 PHOTOMETRIC DATA: QHC-UL-60C-700-51K-OAO All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA INDOOR CANDELA PLOT ZONAL LUMEN SUMMARY 90 QHC-UL-60C-700-51K-OAO LED150W-053-C2800-M-D 1.00 LED 15137 133 Suspended N.A. 0° = 1.00 90° = 1.00 Length: 0.69 Width: 0.69 Height: 0.00 60 8108 AVG. LUMINANCE (Candela/Sq. M.) 50 10 20 RCR 70 30 119 105 93 83 75 67 61 55 51 46 43 10 119 103 89 78 69 62 55 50 46 42 38 70 116 109 102 95 89 83 78 73 68 64 60 22 44 66 98 99 100 70 80 50 119 108 98 90 82 74 68 63 58 54 50 %Fixt N.A. N.A. N.A. N.A. N.A. N.A. 5406 30 0.0 40 COEFFICIENTS OF UTILIZATION (%) 70 119 112 105 98 91 85 79 74 69 65 61 %Lamp 3387 6681 9955 14769 15057 15137 80 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ RC Lumens 0-20 0-30 0-40 0-60 0-80 0-90 2703 10811 0 RW 0 1 2 3 4 5 6 7 8 9 10 Zone Average Luminance Angle Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet 50 116 106 97 88 80 73 67 62 57 53 49 50 30 116 104 92 82 74 67 60 55 50 46 43 10 116 101 88 78 69 61 55 50 45 42 38 50 111 102 93 85 78 71 66 61 56 52 48 30 111 100 90 80 72 65 59 54 50 46 42 0 10 111 98 86 76 68 61 55 50 45 41 38 0 100 90 81 72 65 58 52 47 43 39 36 25 45 65 0 10804 10804 10804 10804 5 10619 10614 10615 10614 10 10054 10174 10153 10061 15 9033 9034 9052 9057 20 8426 8400 8386 8423 25 7614 7550 7502 7571 30 7131 7043 6981 7062 35 5917 5841 5719 5771 40 5556 5292 5068 5153 45 3455 3450 3330 3457 55 214 215 221 218 65 173 145 147 147 75 78 77 70 76 85 46 48 47 47 90 10804 10617 10064 9058 8458 7643 7145 5808 5378 3526 215 182 77 46 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance OPERATING ENVIRONMENT Proposed System Min Temp Max Temp QHC-UL-36C -30°C/-22°F 45°C/113°F QHC-UL-48C -30°C/-22°F 45°C/113°F QHC-UL-60C -30°C/-22°F 45°C/113°F QHC-UL-120C -30°C/-22°F 45°C/113°F QHC-UL-180C -30°C/-22°F 45°C/113°F Application Notes 1. Application temperatures are provided to ensure the longevity and performance of the driver and LEDs. 2. Results are based off the In-Situ Temperature Measurement Test (ISTMT) along with the drivers' temperature and life curves. 3. Precision-Paragon [P2]'s 5 year warranty assumes operation at the maximum ambient temperature range. 4. Must mount fixture a minimum of 24" below ceiling. LUMEN PACKAGE OPTIONS - OAO DISTRIBUTION Proposed System Light Source Quantity & Type CRI CCT Lumens Per Fixture Input Watts Lumens Per Watt QHC-UL-36C 1 QHC 87W 70 5100K 9,947 87 114 QHC-UL-48C 1 QHC 115W 70 5100K 13,057 115 114 QHC-UL-60C 1 QHC 135W 70 5100K 15,137 133 114 QHC-UL-120C 1 QHC 270W 70 5100K 30,272 266 114 QHC-UL-180C 1 QHC 405W 70 5100K 45,410 399 114 *Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards. Page 3/6 - Revised 09/30/14 © 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com QHC Modular Chassis LED High-Bay PHOTOMETRIC DATA - LBO DISTRIBUTION Test: L03131102 Test Date: 03/05/13 PHOTOMETRIC DATA: QHC-UL-60C-700-51K-LBO All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA ZONAL LUMEN SUMMARY 90 QHC-UL-60C-700-51K-LBO LED150W-053-C2800-M-D 1.00 LED 15150 134 Suspended N.A. 0° = 2.76 90° = 2.30 Length: 0.78 Width: 0.78 Height: 0.00 60 4214 AVG. LUMINANCE (Candela/Sq. M.) 50 10 20 30 RCR 70 30 119 90 69 54 44 37 31 27 24 21 19 10 119 85 61 46 35 28 23 20 17 15 13 70 116 100 87 77 68 62 56 52 48 45 42 4 10 18 48 95 100 2809 80 50 119 97 79 65 56 48 42 38 34 31 28 %Fixt N.A. N.A. N.A. N.A. N.A. N.A. 70 40 COEFFICIENTS OF UTILIZATION (%) 70 119 104 90 80 71 64 58 54 50 46 43 %Lamp 649 1511 2742 7195 14404 15150 80 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ RC Lumens 0-20 0-30 0-40 0-60 0-80 0-90 1405 5618 0 RW 0 1 2 3 4 5 6 7 8 9 10 Zone Average Luminance Angle Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet INDOOR CANDELA PLOT 50 116 94 77 64 54 47 41 37 33 30 27 50 30 116 88 68 53 43 36 31 27 23 21 19 10 116 83 60 45 35 28 23 20 17 15 13 50 111 90 73 60 51 44 39 35 32 29 26 30 111 85 65 51 42 35 30 26 23 20 18 0 10 111 80 59 44 35 28 23 19 17 14 13 0 100 73 53 40 31 24 20 17 14 12 11 0 5 10 15 20 25 30 35 40 45 55 65 75 85 0.0 25 45 65 90 1858 1844 1807 1741 1795 2031 2169 2604 2845 3173 4775 5024 1223 134 1858 1842 1826 1749 1832 2047 2194 2666 2929 3220 3847 5610 1924 96 1858 1843 1829 1762 1846 2089 2248 2697 3004 3290 3727 4342 772 56 1858 1849 1929 1785 1860 2031 2157 2614 2899 3190 3786 4699 1367 80 1858 1855 1934 1801 1859 2036 2153 2564 2782 3058 4158 3637 840 104 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance OPERATING ENVIRONMENT Proposed System Min Temp Max Temp QHC-UL-36C -30°C/-22°F 45°C/113°F QHC-UL-48C -30°C/-22°F 45°C/113°F QHC-UL-60C -30°C/-22°F 45°C/113°F QHC-UL-120C -30°C/-22°F 45°C/113°F QHC-UL-180C -30°C/-22°F 45°C/113°F Application Notes 1. Application temperatures are provided to ensure the longevity and performance of the driver and LEDs. 2. Results are based off the In-Situ Temperature Measurement Test (ISTMT) along with the drivers' temperature and life curves. 3. Precision-Paragon [P2]'s 5 year warranty assumes operation at the maximum ambient temperature range. 4. Must mount fixture a minimum of 24" below ceiling. LUMEN PACKAGE OPTIONS - LBO DISTRIBUTION Proposed System Light Source Quantity & Type CRI CCT Lumens Per Fixture Input Watts Lumens Per Watt QHC-UL-36C 1 QHC 87W 70 5100K 9,847 87 113 QHC-UL-48C 1 QHC 115W 70 5100K 12,957 115 113 QHC-UL-60C 1 QHC 135W 70 5100K 15,150 134 113 QHC-UL-120C 1 QHC 270W 70 5100K 30,300 268 113 QHC-UL-180C 1 QHC 405W 70 5100K 45,450 402 113 *Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards. Page 4/6 - Revised 09/30/14 © 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com QHC Modular Chassis LED High-Bay PROJECTED LUMEN MAINTENANCE Operating Hours 0 10,000 20,000 25,000 35,000 50,000 60,000 75,000 100,000 Lumen Maintenance Factor 1.00 0.99 0.981 0.98 0.98 0.97 0.97 0.96 0.95 LUMENS VS. AMBIENT TEMPERATURE Ambient °C Ambient °F Lumen Multiplier -15 -7 2 10 18 27 35 43 52 60 5 20 35 50 65 80 95 110 125 140 1.11 1.09 1.07 1.05 1.02 1.00 0.96 0.92 0.87 0.71 FIXTURE DIMENSIONS 18.24 12.63 9.45 3.00 5.11 7.03 REMOVABLE DRIVER ACCESS Hinge Disconnect Features 1. Two point opening 2. Hinged for safety 3. Ease of driver maintenance Driver Surge protector QHC QUICK TOP BOX Ø .704 (Designed for ½" cord grips/connectors) 2.100 3.496 5.996 Fixture mounted junction box for wiring direct to luminaire. Page 5/6 - Revised 09/30/14 © 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com QHC Modular Chassis LED High-Bay MODULAR CHASSIS QHC-UL-180C (405 WATT) QHC-UL-120C (270 WATT) *Images N.T.S. Page 6/6 - Revised 09/30/14 © 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com