Transcript
QHC
Modular Chassis LED High-Bay Product Information Project Name
Type
Catalog Number
Date
SPECIFICATIONS Features • • • • • • • • • • • •
Single 135W fixture directly replaces a 400W HID and equivalent systems. Modular design allows multiple chassis configurations for higher wattage applications. Ideal one-for-one replacement of conventional HID high-bay systems. IP66 applications standard, with sensor fixture is IP65 rated. Provides controlled uniform light distribution with acrylic optics without color shift. Aisle optics deliver superior vertical illumination. Long-life LEDs at L95 (95% lumen maintenance) at 60,000 hours reduce life cycle maintenance costs. Choice of four lumen packages and dimming option available. Rigid durable housing & solid state light engine are resistant to vibration. Up to 114 lumens per watt. Simple three step installation: hang gripple, snap gripple hook hangers to fixture & plug-in/wire fixture. Made In USA. Meets ARRA & Buy American requirements.
Construction • • • • • • • •
Lightweight cast aluminum post powder coated housing Integral thermistor circuit prevents over heating of LED system Modular LED light engine. Certain airborne contaminants can diminish integrity of acrylic. Consult factory for chemical compatibility. Replaceable driver door allows for quick driver maintenance Optional integral sensor provides enhanced energy savings Optional cast aluminum top box for power connections Weight: 19 lbs.
Certifications • • • • •
Application
Electrical • • • • • • • • •
CSA listed for U.S. & Canada. Tested to UL 1598 & UL 8750 standards. Luminaires bear appropriate listing labels. Adheres to LM79, LM80 and TM21 industry standards. DesignLights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org.
• Suitable for use with most wired or wireless lighting control systems • Target opportunities include: • Manufacturing • Freezers • Warehouses • Storage • Shipping • High-Bay • Outdoor • Low-Bay
Input Voltage Range: 100-277 VAC Nom. (90-305 V Min/Max) Frequency: 50/60 Hz Nom. (47-63 Hz Min/Max) Power Factor: >0.90 @ full load, 100V through 277V Inrush Current: < 65 Amps max @ 230 VAC, cold start 25ºC (135W) Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Temperature (110º) & Short Circuit with self-recovery Compliant to FCC Part 15 requirements for EMI/RFI emissions NEC/CEC compliant ballast disconnect is standard. Standard surge protection: ANSI Std. C62.41.2 Category A (10 kV)
Warranty
• Five-year warranty. (Terms and Conditions Apply)
CERTIFICATION IP65
IP65
CERTIFIED
CERTIFIED
LED Product Partner
ORDERING INFORMATION – MODEL QHC LED
High-Bay
VOLTAGE
–
DRIVER CURRENT
36C 36 Chip1
700 700mA
48C 48 Chip1 Board
UL 120-277 VAC
1
347 347 VAC 480 480 VAC
–
QTY OF LED CHIPS Board
60C 60 Chip
2
Board
1
–
–
OPTICS
AAO Asymmetrical Aisle Optics
OAO Open Area
COLOR TEMP 51K 5100
120C 120 Chip3 Board
180C 180 Chip3 FOOTNOTES
EXAMPLE QHC-UL-60C-700-51K-AAO-10GYSH
IP65 CERTIFIED
–
Board
Non DLC with AAO & NAO optics. 2 Non DLC with NAO optics. 3 Non DLC. 4 HBA only. IP65 rated. 5 Sensor programming module sold separately, FSIR-100. 6 Contact factory for additional cord & mounting options. Page 1/6 - Revised 09/30/14
Optics
LBO Low-Bay Optics
NAO Narrow Aisle Optics1
– OCC SENSOR
– CORD PLUG 6
WH Wet Location
C8 8' Cord,
WL Wet Location
C8/ 8' Cord L715 & Plug
High-Bay Sensor4 Low-Bay Sensor4
DH-WH Digital Dimming, Wet Location High-Bay Sensor, WS5
DH-WL Digital Dimming, Wet Location Low-Bay Sensor, WS5
No Plug
(L7-15P)
C8/515 8' Cord &
Plug (515P)
PQC15 15' Cord/
OTHER 10GYSH 10' Gripple Y SnapHook Hangers
QTB QHC Quick
Top Box for Power Connectors
JP Job Pack
Quick Connect
DB-WH Digital Bi-Level, Wet Location High-Bay Sensor, HBA
DB-WL Digital Bi-Level, Wet Location Low-Bay Sensor, HBA
© 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com
QHC
Modular Chassis LED High-Bay PHOTOMETRIC DATA - AAO DISTRIBUTION Test: L09124201 Test Date: 09/20/12
PHOTOMETRIC DATA: QHC-UL-60C-700-51K-AAO All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA
INDOOR CANDELA PLOT
ZONAL LUMEN SUMMARY 90
QHC-UL-60C-700-51K-AAO LED150W-053-C2800-M-D 1.00 LED 12484 132 Suspended N.A. 0° = 0.92 90° = 0.60 Length: 0.69 Width: 0.69 Height: 0.00
RCR
50 119 104 93 83 76 69 64 59 55 51 48
10 119 97 81 70 62 55 50 45 42 38 36
70 116 106 98 91 84 79 74 69 65 62 58
25 44 59 81 96 100
70
60
7835
AVG. LUMINANCE (Candela/Sq. M.) 50
10
20
30
0.0
40
0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ 70
30 119 100 87 76 68 61 56 51 47 44 41
%Fixt
N.A. N.A. N.A. N.A. N.A. N.A.
5224
80 70 119 109 101 93 87 81 76 71 67 63 60
%Lamp
3105 5504 7318 10101 11956 12483
80
COEFFICIENTS OF UTILIZATION (%) RC
Lumens
0-20 0-30 0-40 0-60 0-80 0-90
2612
10447 0
RW 0 1 2 3 4 5 6 7 8 9 10
Zone
Average Luminance Angle
Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet
50 116 102 91 82 74 68 63 58 54 50 47
50 30 116 98 85 75 67 61 55 51 47 43 40
10 116 95 80 70 61 55 50 45 42 38 36
50 111 98 88 79 72 66 61 57 53 49 46
30 111 95 83 73 66 59 54 50 46 43 40
0 10 111 92 78 68 61 54 49 45 41 38 36
0 100 84 73 64 57 51 47 43 39 36 34
25
45
0 10446 10446 10446 5 10138 10022 9837 10 9318 9923 9817 15 8262 9429 9112 20 7830 8966 8073 25 6801 7615 5900 30 6121 6777 4604 35 5038 5283 2684 40 4239 3742 2334 45 3516 3162 1388 55 2924 2076 956 65 1802 1224 682 75 495 703 544 85 219 326 246
65
90
10446 9609 9170 7611 5873 3381 2210 1054 882 824 729 657 464 272
10446 9497 8893 6594 4074 2050 1494 915 833 749 717 592 407 284
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
OPERATING ENVIRONMENT Proposed System
Min Temp
Max Temp
QHC-UL-36C
-30°C/-22°F
45°C/113°F
QHC-UL-48C
-30°C/-22°F
45°C/113°F
QHC-UL-60C
-30°C/-22°F
45°C/113°F
QHC-UL-120C
-30°C/-22°F
45°C/113°F
QHC-UL-180C
-30°C/-22°F
45°C/113°F
Application Notes
1. Application temperatures are provided to ensure the longevity and performance of the driver and LEDs. 2. Results are based off the In-Situ Temperature Measurement Test (ISTMT) along with the drivers' temperature and life curves. 3. Precision-Paragon [P2]'s 5 year warranty assumes operation at the maximum ambient temperature range. 4. Must mount fixture a minimum of 24" below ceiling.
LUMEN PACKAGE OPTIONS - AAO DISTRIBUTION Proposed System
Light Source Quantity & Type
CRI
CCT
Lumens Per Fixture
Input Watts
Lumens Per Watt
QHC-UL-36C
1
QHC 87W
70
5100K
7,547
87
87
QHC-UL-48C
1
QHC 115W
70
5100K
10,357
115
90
QHC-UL-60C
1
QHC 135W
70
5100K
12,483
131
95
QHC-UL-120C
1
QHC 270W
70
5100K
24,966
262
95
QHC-UL-180C
1
QHC 405W
70
5100K
37,449
393
95
*Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards. Page 2/6 - Revised 09/30/14
© 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com
QHC
Modular Chassis LED High-Bay PHOTOMETRIC DATA - OAO DISTRIBUTION Test: L02134304R01 Test Date: 03/07/13
PHOTOMETRIC DATA: QHC-UL-60C-700-51K-OAO All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA
INDOOR CANDELA PLOT
ZONAL LUMEN SUMMARY 90
QHC-UL-60C-700-51K-OAO LED150W-053-C2800-M-D 1.00 LED 15137 133 Suspended N.A. 0° = 1.00 90° = 1.00 Length: 0.69 Width: 0.69 Height: 0.00
60
8108
AVG. LUMINANCE (Candela/Sq. M.) 50
10
20
RCR
70 30 119 105 93 83 75 67 61 55 51 46 43
10 119 103 89 78 69 62 55 50 46 42 38
70 116 109 102 95 89 83 78 73 68 64 60
22 44 66 98 99 100
70
80 50 119 108 98 90 82 74 68 63 58 54 50
%Fixt
N.A. N.A. N.A. N.A. N.A. N.A.
5406
30
0.0
40
COEFFICIENTS OF UTILIZATION (%) 70 119 112 105 98 91 85 79 74 69 65 61
%Lamp
3387 6681 9955 14769 15057 15137
80
0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ RC
Lumens
0-20 0-30 0-40 0-60 0-80 0-90
2703
10811 0
RW 0 1 2 3 4 5 6 7 8 9 10
Zone
Average Luminance Angle
Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet
50 116 106 97 88 80 73 67 62 57 53 49
50 30 116 104 92 82 74 67 60 55 50 46 43
10 116 101 88 78 69 61 55 50 45 42 38
50 111 102 93 85 78 71 66 61 56 52 48
30 111 100 90 80 72 65 59 54 50 46 42
0 10 111 98 86 76 68 61 55 50 45 41 38
0 100 90 81 72 65 58 52 47 43 39 36
25
45
65
0 10804 10804 10804 10804 5 10619 10614 10615 10614 10 10054 10174 10153 10061 15 9033 9034 9052 9057 20 8426 8400 8386 8423 25 7614 7550 7502 7571 30 7131 7043 6981 7062 35 5917 5841 5719 5771 40 5556 5292 5068 5153 45 3455 3450 3330 3457 55 214 215 221 218 65 173 145 147 147 75 78 77 70 76 85 46 48 47 47
90 10804 10617 10064 9058 8458 7643 7145 5808 5378 3526 215 182 77 46
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
OPERATING ENVIRONMENT Proposed System
Min Temp
Max Temp
QHC-UL-36C
-30°C/-22°F
45°C/113°F
QHC-UL-48C
-30°C/-22°F
45°C/113°F
QHC-UL-60C
-30°C/-22°F
45°C/113°F
QHC-UL-120C
-30°C/-22°F
45°C/113°F
QHC-UL-180C
-30°C/-22°F
45°C/113°F
Application Notes
1. Application temperatures are provided to ensure the longevity and performance of the driver and LEDs. 2. Results are based off the In-Situ Temperature Measurement Test (ISTMT) along with the drivers' temperature and life curves. 3. Precision-Paragon [P2]'s 5 year warranty assumes operation at the maximum ambient temperature range. 4. Must mount fixture a minimum of 24" below ceiling.
LUMEN PACKAGE OPTIONS - OAO DISTRIBUTION Proposed System
Light Source Quantity & Type
CRI
CCT
Lumens Per Fixture
Input Watts
Lumens Per Watt
QHC-UL-36C
1
QHC 87W
70
5100K
9,947
87
114
QHC-UL-48C
1
QHC 115W
70
5100K
13,057
115
114
QHC-UL-60C
1
QHC 135W
70
5100K
15,137
133
114
QHC-UL-120C
1
QHC 270W
70
5100K
30,272
266
114
QHC-UL-180C
1
QHC 405W
70
5100K
45,410
399
114
*Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards. Page 3/6 - Revised 09/30/14
© 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com
QHC
Modular Chassis LED High-Bay PHOTOMETRIC DATA - LBO DISTRIBUTION Test: L03131102 Test Date: 03/05/13
PHOTOMETRIC DATA: QHC-UL-60C-700-51K-LBO All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA
ZONAL LUMEN SUMMARY 90
QHC-UL-60C-700-51K-LBO LED150W-053-C2800-M-D 1.00 LED 15150 134 Suspended N.A. 0° = 2.76 90° = 2.30 Length: 0.78 Width: 0.78 Height: 0.00
60
4214
AVG. LUMINANCE (Candela/Sq. M.)
50
10
20
30
RCR
70 30 119 90 69 54 44 37 31 27 24 21 19
10 119 85 61 46 35 28 23 20 17 15 13
70 116 100 87 77 68 62 56 52 48 45 42
4 10 18 48 95 100
2809
80 50 119 97 79 65 56 48 42 38 34 31 28
%Fixt
N.A. N.A. N.A. N.A. N.A. N.A.
70
40
COEFFICIENTS OF UTILIZATION (%) 70 119 104 90 80 71 64 58 54 50 46 43
%Lamp
649 1511 2742 7195 14404 15150
80
0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _
RC
Lumens
0-20 0-30 0-40 0-60 0-80 0-90
1405
5618 0
RW 0 1 2 3 4 5 6 7 8 9 10
Zone
Average Luminance Angle
Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet
INDOOR CANDELA PLOT
50 116 94 77 64 54 47 41 37 33 30 27
50 30 116 88 68 53 43 36 31 27 23 21 19
10 116 83 60 45 35 28 23 20 17 15 13
50 111 90 73 60 51 44 39 35 32 29 26
30 111 85 65 51 42 35 30 26 23 20 18
0 10 111 80 59 44 35 28 23 19 17 14 13
0 100 73 53 40 31 24 20 17 14 12 11
0 5 10 15 20 25 30 35 40 45 55 65 75 85
0.0
25
45
65
90
1858 1844 1807 1741 1795 2031 2169 2604 2845 3173 4775 5024 1223 134
1858 1842 1826 1749 1832 2047 2194 2666 2929 3220 3847 5610 1924 96
1858 1843 1829 1762 1846 2089 2248 2697 3004 3290 3727 4342 772 56
1858 1849 1929 1785 1860 2031 2157 2614 2899 3190 3786 4699 1367 80
1858 1855 1934 1801 1859 2036 2153 2564 2782 3058 4158 3637 840 104
RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance
OPERATING ENVIRONMENT Proposed System
Min Temp
Max Temp
QHC-UL-36C
-30°C/-22°F
45°C/113°F
QHC-UL-48C
-30°C/-22°F
45°C/113°F
QHC-UL-60C
-30°C/-22°F
45°C/113°F
QHC-UL-120C
-30°C/-22°F
45°C/113°F
QHC-UL-180C
-30°C/-22°F
45°C/113°F
Application Notes
1. Application temperatures are provided to ensure the longevity and performance of the driver and LEDs. 2. Results are based off the In-Situ Temperature Measurement Test (ISTMT) along with the drivers' temperature and life curves. 3. Precision-Paragon [P2]'s 5 year warranty assumes operation at the maximum ambient temperature range. 4. Must mount fixture a minimum of 24" below ceiling.
LUMEN PACKAGE OPTIONS - LBO DISTRIBUTION Proposed System
Light Source Quantity & Type
CRI
CCT
Lumens Per Fixture
Input Watts
Lumens Per Watt
QHC-UL-36C
1
QHC 87W
70
5100K
9,847
87
113
QHC-UL-48C
1
QHC 115W
70
5100K
12,957
115
113
QHC-UL-60C
1
QHC 135W
70
5100K
15,150
134
113
QHC-UL-120C
1
QHC 270W
70
5100K
30,300
268
113
QHC-UL-180C
1
QHC 405W
70
5100K
45,450
402
113
*Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards. Page 4/6 - Revised 09/30/14
© 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com
QHC
Modular Chassis LED High-Bay PROJECTED LUMEN MAINTENANCE Operating Hours
0
10,000
20,000
25,000
35,000
50,000
60,000
75,000
100,000
Lumen Maintenance Factor
1.00
0.99
0.981
0.98
0.98
0.97
0.97
0.96
0.95
LUMENS VS. AMBIENT TEMPERATURE Ambient °C Ambient °F Lumen Multiplier -15 -7 2 10 18 27 35 43 52 60
5 20 35 50 65 80 95 110 125 140
1.11 1.09 1.07 1.05 1.02 1.00 0.96 0.92 0.87 0.71
FIXTURE DIMENSIONS 18.24
12.63
9.45
3.00
5.11
7.03
REMOVABLE DRIVER ACCESS
Hinge Disconnect
Features 1. Two point opening 2. Hinged for safety 3. Ease of driver maintenance
Driver Surge protector
QHC QUICK TOP BOX Ø .704
(Designed for ½" cord grips/connectors)
2.100
3.496
5.996
Fixture mounted junction box for wiring direct to luminaire.
Page 5/6 - Revised 09/30/14
© 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com
QHC
Modular Chassis LED High-Bay MODULAR CHASSIS QHC-UL-180C (405 WATT)
QHC-UL-120C (270 WATT)
*Images N.T.S.
Page 6/6 - Revised 09/30/14
© 2014 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Tel [West Coast] 714.386.5550 [Midwest] 715.381.2971 [East Coast] 352.692.5900 / Website www.P-2.com