Preview only show first 10 pages with watermark. For full document please download

Modulys Rm From 1500 To 9000 Va For 19” Rack Applications Single-phase Ups

   EMBED


Share

Transcript

MODULYS RM Single-phase UPS from 1500 to 9000 VA for 19” rack applications The solution for > Computer networks > Telecommunications mod 029 B > LAN / WAN networks A 19” rack solution” Modular back-up time • The Mod-RM series enables the UPS and all the protected equipment (HUB, server, back-up units, etc.) to be integrated into a single 19” rack. These modules are prewired so that connection is easier, simplifying installation. • In the same way, the spaces available enable the Mod-Battery to be added to increase back-up time. An adaptable system • Mod-RM has been specifically designed for usage up to 9 kVA, which requires a combination of reliability and adaptability. • The free slots in each model enable the Mod-Power to be added to provide redundancy for the system or to increase the power. 28 General Catalogue 2012 - 2013 System upgrades • Units bought separately (Mod-TW or Mod-RK) can be installed at a later date in a Mod-System, fulfilling your needs for modularity and redundancy. MODULYS RM from 1500 to 9000 VA Single-phase UPS An adaptable system VA Range For your needs from 1500 to 9000 VA Back-up time (minutes)(1) 10 20 30 40 50 60 70 80 90 100 110 120 130 1500 3000 4500 MO MO DUL YS (1) Max BUT @ 75% load Model Mod-Power Battery pack Mod-RM 315 1 x 1500 VA 1 Technical data 1500 1050 Model Mod-Power Battery pack Mod-RM 330 1 x 3000 VA 2 • Separate bypass input. 3000 2100 1/1 230 V ± 20% (up to -30% at 70% nominal load) 50/60 Hz ± 10% > 0.99 / 6% 230 V ± 3% (adjustable 208/220/240 V) 50/60 Hz ± 2% (± 0.1% autonomous frequency) 110% for 1 minute, 130% for 10 seconds, 200% for 5 cycles 3:1 Electrical options • Temperature sensor. Standard communication features • 2 slots for communication options. • MODBUS/JBUS RTU. Communication options • Dry-contact interfaces. • Remote mimic panel. • NET VISION: professional WEB/SNMP interface for UPS monitoring and shutdown management of several operating systems. voltage selected ± 15% frequency selected ± 2% up to 91% 97% from 0 °C up to +40 °C (from 15 °C to 25 °C for maximum battery life) 0% - 90% without condensation 1000 m without derating (max. 3000 m) Mod-System Dimensions W x D x H Weight Degree of protection Acoustic level at 1 m (ISO 3746) Heat dissipation Input connections Output connections STANDARDS Safety EMC Performance Product declaration dcg_84083 DUL YS Standard electrical features MODULYS RM Mod-Power Sn [VA] Pn [W]  Input / output INPUT Rated voltage Voltage tolerance Rated frequency Frequency tolerance Power factor / THDI OUTPUT Rated voltage Voltage tolerance Rated frequency Frequency tolerance Overload Crest factor BYPASS Rated voltage Voltage tolerance Rated frequency Frequency tolerance EFFICIENCY Online mode Eco Mode ENVIRONMENT Operating ambient temperature Relative humidity Maximum altitude DUL YS mod 069 A Standard BUT Maximum BUT MO DUL YS mod 068 A mod 078 A 9000 MO 3 slots 19" x 550 mm x 12U 57 kg (Mod-RM 315), 68 kg (Mod-RM 330) IP20 < 52 dBA 780 W terminals terminals + 2 x IEC 320 C19 (16 A) EN 62040-1 IEC 62040-2 EN 62040-3 CE VALID FOR FRANCE VALID FOR ITALY ISO 9001 FM 28237 www.socomec.com General Catalogue 2012 - 2013 Non contractual document. ISO14001 EMS 553476 © 2012, Socomec SA. All rights reserved. 29