Transcript
MODULYS
®
Modular UPS from 1.5 up to 24 kVA FOR COMPUTER, TELECOM & INTERNET NETWORKS
THE BEST WAY TO GROW UPS
SOCOMEC GROUP SWITCHGEAR AND UPS
SOCOMEC, an independent manufacturer
Flexible
The SOCOMEC Group employs 1700 people and has a turnover in excess of € 190 million. Its core activities are the manufacture of electrical products and electronic equipment. The company has full industrial control in both of its specialist divisions, guaranteed by ISO 9001:2000 certification.
The extreme dynamism of today’s companies requires constructive state-of-the-art solutions. SOCOMEC SICON UPS offers its clients the total adaptability and flexibility of MODULYS for their various architectures and plants. The three power ratings available for each Mod-Power, the possibility to “migrate” from a Tower configuration (Mod-TW) to the 19” Rack (Mod-RK) and subsequently into the Mod-System, all contribute to make MODULYS the most flexible and reliable solution for the supply of protected power to your critical installations.
> The UPS that grows with your company
The wide range of models specifically designed to meet your requirements means that you can choose the one that is most suited to your needs, safe in the knowledge that adapting the UPS to your future power and back-up requirements will not be a problem.
Economical 3 factories in France, 2 factories in Italy
SOCOMEC SICON UPS: know-how Located in France and in Italy, SOCOMEC SICON UPS extends way beyond European borders. The company has based its strategy on two main policies: • total quality of its products and services • adaptability to specific customer needs
> The UPS that saves your money Investing only in the indispensable is finally a viable strategy. The totally modular nature of MODULYS means that your initial investment is safeguarded; not only can all the stand alone units be used in Tower or Rack versions, but they can also be housed inside the Mod-System, thus forming the foundation of your system. The real capability to increase power and back-up simply by adding modules is a guarantee that adapting the UPS to your company will truly be economical. Unnecessary expense is a thing of the past; your investment today will be the basis of your future growth.
Simple > The UPS that has everything, yet is easy to manage SOCOMEC SICON UPS offers a complete range of solutions suited to various IT, industrial and telecommunications configurations: • UPS from 300 VA to 4800 kVA • rectifier-chargers from 7.5 to 6000 A • DC/AC converters from 7.5 to 18 kVA • static transfer switch from 16 to 4800 A • harmonic compensators • 400Hz frequency converters
SOCOMEC also manufactures:
SOCOMEC SICON UPS are committed offering a UPS solution that is complete and has a wide variety of features, while at the same time ensuring that installation, use and maintenance are simpler than ever. The Mod-Power and the Mod-Battery units are “plug-ins”, while the communication cards are quick and easy to install.
Reliable > The UPS with the best technology MODULYS is synonymous with highly reliable technology. All control and monitoring functions are supported by fully digital circuitry, guaranteeing the highest possible operating reliability under all environmental conditions.
A range of Switching and Protection Systems. Future growth of the Group will also be fuelled by a second industrial activity independent of its UPS systems, i.e. low voltage industrial switches and protection systems. This Division designs and manufactures the widest range of: • load break switches • changeover switches • fuse protection • energy and control management • safety enclosures…
MODULYS is also characterized by the adoption of innovative solutions as yet unknown to its competitors. Each Mod-Power has in fact an internal controller. By adopting this architecture, each Mod-Power is able to operate independently, thus guaranteeing the total reliability of the whole system. If one ModPower is not working, this will have no effect on system operation, the module will simply be excluded from the system. The same concept of total independence also applies to the Mod-Battery units. If one Mod-Battery is not working, the power supply will not be interrupted.
For further information: www.socomec-sicon.com
For further information: www.modulys.com
MOD 024A
MODULYS ® The answer to all your needs > Do your needs change over time? MODULYS adapts easily to changes and to the growth of your system. SOCOMEC SICON UPS is the only company able to offer you power modules (Mod-Power) of 1.5, 3, 4.5 and 6 kVA, offering a complete family of products which, in the Tower, Rack and Mod-System versions, are easily combined to ensure the ideal configuration for your present and future power supply requirements.
> Does the protection have to be total? MODULYS is a modular UPS: the number of Mod-Power and Mod-Battery units can easily be increased to provide redundant operation, from N + 1 to N + X. In this way, total availability of the system is achieved (High Availability), even if one or more modules are inoperative.
> Does the protection have to be continuous? SOCOMEC SICON UPS has thought of this, too. In fact the Mod-Power and Mod-Battery units are of the Plug-in type, which can be replaced or inserted while the system is in operation (Hot swap). In this way, true continuity of power supplied to the load is achieved, without any interruption of service.
> Is it difficult to foresee your future needs? The modular configuration of MODULYS allows you to increase the number of Mod-Power and Mod-Battery units, thus increasing your uninterruptible power system’s power and back-up. In this way you can easily cope with future situations which you are not able to predict today.
Technology is the trademark of a great company. SOCOMEC SICON UPS can offer: > No single point of failure solutions
> Is space a scarce resource?
Each individual Mod-Power has its own integrated controller and automatic by-pass. In the Mod-System, this design is an additional guarantee since the load will be powered even if one of the Mod-Power is not working.
This is why MODULYS is the most compact UPS in its category. It really requires very little space to install it, whether in the stand-alone versions or in the numerous Mod-System configurations.
> Full digital control technology MODULYS is completely controlled by digital circuits. The use of digital circuits allows for greater precision and ensures stability over time of the operating parameters of the whole system.
> Top level communication solutions A full set of communication solutions makes the MODULYS range the most open UPS to communicate. It comes with RS232 serial interface as standard. It also offers a wide range of additional solutions to adapt to each customer environment: “Dry contact” relay board, NET VISION SNMP/web adapter and Advanced communication card, allowing for environmental control function and a second RS232/485 serial interface.
> On-line double conversion technology
MOD 023A
The most effective technology for protecting data from mains outage as well as other types of electrical failures. It’s VFI (Voltage Frequency independent) feature, means that the inverter which generates the output voltage permanently supplies the load. Continuity and stability of both the voltage and frequency is thus ensured, irrespective of the mains input.
> Energy management solutions • Power share plug: this is a standard socket dedicated to non-critical loads. It’s able to disconnect its load when a preset condition (relative to remaining back-up) occurs, to save battery back-up time for critical loads. • Eco mode: this operating mode has been designed to power noncritical loads, in order to reduce power consumption on the UPS. • Remote shut down to shut down the UPS from a remote station with NET VISION. • Frequency converter: the frequency converter allows for a 50 Hz input and a 60 Hz output, or vice versa. • Neutral arrangement: MODULYS is also compatible with IT earthing arrangement.
MODULYS UPS
Modular UPS from 1.5 up to 24 kVA for computer, telecom & internet networks
APPLI 033A
> UNIT FOR PROFESSIONAL APPLICATIONS The stand alone unit in Tower or Rack version is ideal for the protection of professional IT applications.
see page 4
APPLI 034A
> STANDARD 19” RACK APPLICATIONS The Mod-RM can easily be installed in your 19” cabinets, providing expanded power and back-up and, above all, redundancy.
see page 6
APPLI 031A
> MISSION CRITICAL APPLICATIONS Designed specifically to safeguard the most critical business applications, the Mod-MC is available in many different configurations designed for all available power ratings.
see page 8
> e-BUSINESS APPLICATIONS APPLI 034A
GROW
The Mod-EB is the solution for all the most complex IT applications (ISP, ASP, etc.).
see page 10
> EMERGENCY APPLICATIONS APPLI 010A
BEST WAY TO
The Mod-EM configurations are the ideal solution to protect all technological plants that need galvanic isolation transformers and lengthy back-up times.
see page 12
> TELECOM APPLICATIONS CORPO 011A
THE
®
The Mod-TC solution has been designed specifically to meet the requirements of telecom applications.
see page 14
MODULYS
®
THE BEST WAY TO GROW UPS
> WHY... make do with the usual UPS, if you can have more? The development of markets and of technology requires companies to make ever more rapid changes. What is valid today may no longer be so tomorrow. Always attentive to market demands, SOCOMEC SICON UPS today is proud to present MODULYS.
MODULYS is in fact totally modular: the wide range of solutions available and the capability to adapt them to your requirements make MODULYS a completely innovative system, designed to be fully integrated in all professional environments and to satisfy the most specific corporate applications.
> A CONCEPT... that keeps abreast of the times
GAMME 011A
MODULYS is flexible and reliable, because it is a “living” system, which models itself and takes shape around your requirements, both present and future.
The concept of evolution is the guiding force behind the MODULYS design philosophy, developped to be easily adaptable to the constant changes required by your loads. The Stand Alone units are available in both Tower (Mod-TW) and Rack (Mod-RK) configurations; but most importantly, the Mod-TW units can easily be converted into Mod-RK units, suitable for installation inside standard 19” cabinets, simply by using the appropriate Kit. This solution enables you to decide on the most appropriate use of your UPS at any time.
Mimic panel
MODULYS is not only a Stand Alone UPS, however: it is also available as a Mod-System in the RM, MC, EB, EM and TC versions, where modularity is synonymous with evolution.
Remote communication panel
Intelligent communication module
With MODULYS, an upgraded system can be built up, composed of the same modules as the Stand Alone units. This means that if today you buy a stand alone unit, tomorrow you could use the very same unit as the first “building brick” of your new Mod-System, making a substantial saving and at the same time spreading the costs over a period of time. As there are several different versions, designed specifically to meet the requirements of each type of application, the MODULYS system is able to satisfy your current needs for a protected power supply, while leaving open the possibility of future expansions thanks to power ratings from 1.5 up to 24 kVA.
Mod-Power
> TECHNOLOGY... that is ahead of the times
Strictly on line double conversion with DSP digital control, MODULYS is of course a redundant UPS, due to the adoption of Load Sharing Technology.
Battery pack MOD 028A
The high technological level of MODULYS can be seen in the materials and the design, which were inspired by aeronautics. It also stands out for being the first in the world in the field of Uninterruptible Power Systems to use hybrid component technology, which enhances the reliability of the power components.
Mod-Battery
The installation of N+1 Mod-Power modules thus always guarantees proper operation of the UPS.
2
3
MODULYS ® TW / RK
Stand Alone Units for professional applications
The only truly expandable single unit
Mod-TW 30 Mod-TW 45 Mod-TW 60
TOWER AND RACK VERSIONS FROM 3KVA TO 6KVA
(Tower versions)
Model
• Multimedia Systems
• HUB - Routers
• Local networks
• Medical-laboratory systems
Model
MOD 014A
MOD 014B
Mod-TW 30
Mod-RK 30
Mod-Power
1x3000VA
Mod-Power
1x3000VA
Battery pack
2
Battery pack
2
Compact and technologically advanced, MODULYS is the ideal solution for the protection of professional applications. Its extended back-up times, achieved via modular battery expansions, are particularly appreciated in IT environments.
MODULYS
MODULYS
MOD 051B
MOD 015A
The wide range of power available (3 - 4.5 - 6 kVA) enables this UPS to satisfy a vast number of requirements and to be the ideal platform for the construction of your future Mod-System. Any model can be converted from Tower version to Rack mounted, by using a simple kit.
MODULYS
Model
Power share plug. Right from the 3 kVA range entry point model, the Power share plug is available. This is a plug dedicated to the protection of non-critical loads that can be disconnected under certain conditions (for example, to extend back-up during battery operation for critical loads).
MOD 052B
(Rack versions)
MOD 013B
MOD 022A
Mod-RK 30 Mod-RK 45 Mod-RK 60
MOD 013A
MODULYS
Mod-TW 45
Model
Mod-RK 45
Mod-Power
1x4500VA
Mod-Power
1x4500VA
Battery pack
3
Battery pack
3
Furthermore, both the Mod-TW 45 / 60 and Mod-RK 45 / 60 are supplied with a functional LCD display as standard. Starting from 4.5kVA units (including furthermore all the Mod-System) a separate input for auxiliary mains is also available.
MODULYS
BACK-UP TIME 4
5
6
7
8
9
10
13
23
30
36
40
46
55
63
Expansions
Mod-Battery
Mod-Battery
MOD 018A
3
8
MOD 018A
2
/
MOD017A
1
Run time min
TLC 017A
MODULYS
3000VA Battery pack
4500VA Battery pack
1
2
3
4
5
6
7
8
9
10
11
12
Model
Run time min
/
/
8
12
18
23
27
31
35
39
42
46
Mod-Power
1x6000VA
Mod-Power
1x6000VA
Battery pack
4
Battery pack
4
Expansions
Mod-Battery
Mod-Battery
6000VA Battery pack
1
2
3
4
5
6
7
8
9
10
11
12
Run time min
/
/
/
8
11
14
19
23
26
29
31
35
Expansions
Mod-Battery
Mod-TW 60
Model
Mod-Battery
(at 75% of the load)
4
5
Mod-RK 60
MODULYS ® RM
Standard 19” Rack applications
Flexible and adaptable installation
Mod-RM315 Mod-RM330
FROM TOWER TO RACK MOUNTED As your requirements change, MODULYS changes with them. A simple Kit is all that is needed to transform Mod-Tower into Mod-Rack. The ideal solution if your UPS is a Mod-Tower and the evolution of your IT environment forces you to transfer all your IT equipment such as Servers, HUBs, UPS and so on, into 19” cabinets.
• Local networks
• Departmental protection
Moreover, the single units purchased as Mod-TW or Mod-RK can subsequently be installed in the Mod-System, supporting in this way your requirements for modularity, redundancy and flexibility.
The Mod-RM series enhances the flexibility of being able to integrate in a single 19” Rack both the UPS and all the protected devices (HUB, server, back-up units, etc.). The wirings are preset to simplify all connections. Redundancy, increased power or increased back-up can all be obtained with this special version of MODULYS. Mod-RM has been specifically designed for those uses up to 9 kVA that need a flexible and extremely reliable system. The availability of free slots in Mod-RM 315 and Mod-RM 330 enables the use of others Mod-Power of the same power to obtain system redundancy or to increase the system’s power.
MOD 031A
• LAN/WAN
MOD 029A
• Telecom equipment
EXPANDABLE FROM 1.5 KVA TO 9 KVA
The space available to insert the Battery pack allows the Mod-RM to sustain long periods of operating back-up, as shown in the back-up configuration on the previous page. MODULYS
MODULYS
MODULYS
Mod-RM 315
Mod-RM 330
Mod-Power
1x1500VA
1x3000VA
Battery pack
1
2
MOD 030A
TLC 028A
Model
MOD 012A
MODULYS
MOD 011A
The ease of managing these units is further enhanced by the availability of the NET VISION option. The SNMP/Web Manager IT enables control of the UPS via a simple Internet Web Browser or by using an NMS (Network Management Station).
7
MODULYS ® MC
Mission Critical applications Technology and modularity for professional uses
Mod-MC 415 Mod-MC 430 Mod-MC 645 Mod-MC 660 Mod-MC 660 six Mod-MC 960 Mod-MC 990 Mod-MC 912 six
EXPANDABLE FROM 1.5 KVA TO 6 KVA
MODULYS
MOD 010A
MODULYS
MODULYS
MOD 009A
MODULYS
Model
• Critical equipment
Mod-MC 415
Mod-MC 430
Mod-Power
1x1500VA
1x3000VA
Battery pack
1
2
• Chemical plants • EDP Centres MOD 032A
EXPANDABLE FROM 4.5 KVA TO 18 KVA
• Production plants • Mainframes • Data storage centres
MODULYS
MODULYS
MODULYS
MODULYS
MODULYS
MODULYS
Mod-MC 660
Mod-MC 660 six
1x4500VA
2x3000VA
1x6000VA
Battery pack
3
4
4
EXPANDABLE FROM 6 KVA TO 24 KVA
MODULYS
MODULYS
MODULYS
MODULYS
MODULYS
MODULYS
MODULYS
MODULYS
MOD 006A
Mod-MC 960, MC 990 and MC 912 six. These are certainly the most powerful and most expandable UPS units of the whole MC range. This configuration has been designed for users who require power and operating back-up. The NET VISION provided as standard with the units meets the requirements of those users who must have a 99.999 % guaranteed reliable service for all the critical uses they handle, as it allows for the remote management of the UPS. This enables the use of the e-SERVICE * program, which represents a further concrete advantage that SOCOMEC SICON UPS is able to offer its clients.
MODULYS
Model
MOD 005A
Mod-MC 645, MC 660 and MC 660 six. These advanced UPS units use higher power Mod-Power. The perfect combination of power and back-up makes this system the pivotal configuration of the whole range, while the high number of slots available allows for further expansion.
Mod-MC 645, MC 660, Mod-MC 990 and MC 912 six can also be installed with three-phase input power supply.
MOD 007A
Mod-MC 645
Mod-Power
MOD 005A
Mod-MC 415 and MC 430. Designed for users with low power needs but who want the possibility of having redundant operation, they use 1.5 and 3 kVA Mod-Power. With N+1 Mod-Power inserted, an extremely secure and economical redundant system can be obtained.
Model
MOD 008A
Available in three different Mod-Systems, with 4, 6 and 9 slots, MODULYS MC adapts perfectly to particularly strategic and sensitive, present and future corporate load protection requirements, where the need for total availability 24 hrs x 7 days makes the applications truly “Mission Critical”.
MOD 007A
MODULYS
Mod-MC 960
Mod-MC 990
Mod-MC 912 six
Mod-Power
2x3000VA
2x4500VA
2x6000VA
Battery pack
4
6
8
* for availability and the delivery arrangements of this service in your area, please contact your authorized SOCOMEC SICON UPS Representative.
8
9
MODULYS ® EB
e-Business applications Power and redundancy for advanced IT uses
EXPANDABLE FROM 9 KVA TO 24 KVA
Mod-EB 1290 Mod-EB 1212 six MODULYS
MODULYS
MODULYS
MODULYS
MODULYS
MODULYS
MOD 001A
• Server farms
MOD 001A
MOD 033A
• Internetworking equipment • ISP / ASP Model
• Call centres
Mod-EB 1290
EB 1212 six
Mod-Power
2x4500VA
2x6000VA
Battery pack
6
8
The “tailor-made” UPS. Genuinely powerful and high-performance, MODULYS EB fully meets the needs of the most demanding user. Data processing centres, ISPs and ASPs, Call Centres and other major IT users can rely on the MODULYS EB as the only system able to guarantee the continuity of the service they offer their clients. It is totally reliable and easy to manage and these make it the “tailor-made” UPS for the most powerful IT applications. The MODULYS EB is the most flexible system and most modular system in the entire range. There is a very large number of slots available with which to increase power and back-up, and also install several Mod-Power in order to provide system redundancy, while still maintaining lengthy back-up.
concept Unit SWAP MOD ULYS
e-SERVICE. Also available is the e-SERVICE* program, which enables the system to send e-mails autonomously to the local Service Centre to report any operating faults in real time. In this way, the local Service Centre will be able to react in the most appropriate way to resolve the problem, with notable advantages in terms of speed and efficiency of the service. Depending on customer requirements, this service can be used to configure a “preventative maintenance” true and proper: automatic control and advanced diagnostics of the various environmental and operating parameters can for example enable the Service Centre to carry out “hot swap” replacement of malfunctioning units, before the client has even had time to realize that there is a malfunction!
FAULT
Preventive maintenance
BAD USE
IC ST NO T AG R DI EPO R
Diagnostic report
e-mail
CIM local center
* for availability and the delivery arrangements of this service in your area, please contact your authorized SOCOMEC SICON UPS Representative
10
MOD ULYS
MOD ULYS
11
MOD 034A GB
The NET VISION, supplied as a standard, means the UPS can be monitored, programmed and controlled either by means of a simple Internet Web Browser or by using an NMS (Network Management Station) to handle the data via SNMP.
MODULYS ® TC
Telecom applications
Power and autonomy for telecommunications
Mod-TC 230 Mod-TC 245 Mod-TC 260 Mod-TC 360 Mod-TC 390
Battery charger MODULYS
UPS MODULYS
Additional slot for a second UPS Batteries with frontal access
MOD 004 A
MOD 046 A
MOD 047 A
• Telecom infrastructure • Network nodes • Radio links • Call centres • Mobile networks
AVAILABLE FROM 3 KVA TO 9 KVA
With its special architecture, specifically designed for the telecommunications sector, and the long back-up time guaranteed by its standard “Long Life” batteries, the Mod-TC is also the ideal solution for installations in remote unmanned places such as radio links, radio mobile stations for cellular phone networks, and GSM - GPRS - UMTS - repeaters.
Model Mod-RK Batterie (48V - 100Ah)
Mod-TC 230
Mod-TC 245
Mod-TC 260
1x3000VA
1x4500VA
1x6000VA
1
1
1
Battery charger
To guarantee constant and reliable operation, the 25 A battery charger provides rapid and stable recharging of 48 V – 100 Ah batteries after each intervention.
MODULYS
The five models we offer differ in the architectures applied to them.
MODULYS
ICM (Intelligent Communication Module) UPS
MODULYS
Mod-TC 2XX the stand alone solution constitute the ideal solution for applications that require high levels of autonomy (over 8 hours for the Mod-TC230), but which do not require increased power.
UPS MODULYS
Free slot for additional UPS
Mod-TC3XX the redundant modular system. With Mod-TC360 and Mod-TC390 you can count on a truly modular solution. Flexible, modular and redundant systems to which it is possible to add extra power modules in order to increase the available power or to obtain N+1 operating redundancy.
MOD 050 A
Batteries with frontal access
Model
Mod-TC 360
Mod-TC 390
2x3000VA
2x4500VA
2
2
Mod-Power Batterie (48V - 100Ah)
14
15
MODULYS ®
MODULYS ®
Plug-in battery and power modules
Available options
Mod-Power
NET VISION (SNMP/WEB manager)
MOD 038 A
1. Fans (number of fans depending on VA) 2. Parallel bus plug-in connection 3. IN/OUT plug-in connection 4. Battery plug-in connection 5. Dip switch for configuration
MOD 039 A
1
1
2
1 3
5
4
MOD 026A
MOD 020 A
With this card, the UPS can be monitored, programmed and controlled either by means of a simple Internet Web Browser or by using an NMS (Network Management Station) to handle the data via SNMP. Specific software modules allow client and server remote shutdown in the network of up to 40 nodes.
e-SERVICE*, enabled via NET VISION allows the system to send diagnostic messages automatically via e-mail to the local Service Centre to report UPS operating failures in real time. In this way, the Service Centre will be able to react in the fastest and most appropriate way to resolve the problem, with obvious advantages in terms of speed and efficiency of the service.
A
Rear view
Dry contact relay. card makes up to three outputs available for remote signals or controls.
The
advanced communication card offers both an environment control function (for example, for input from alarm systems) and a second RS232/485 serial interface.
Mod-Battery
Room temperature control: a sensor is available to keep the environmental temperature of an IT room under control; setting of overtemperature alarms for remote signals and control.
MOD 040 A
MOD 042 A
MOD 041 A
LCD Remote Communication Panel: The remote mimic panel is a
Battery pack
1. Battery plug-in connection 2. AC Supply for internal charger (plug-in)
MOD 043 A
2 1 Rear view
monitoring graphical device that can be used to monitor the UPS and display its main operating functions. Communication with the user can take place in various languages, including Russian and Chinese. It is possible to: - display the system’s operating status - check the status of the UPS by means of the LEDs - log all events on file.
Input/output isolation transformer allows the electrical safety operating level to be increased (failure on the line) in some environments or permits the neutral arrangements to be changed.
External manual by-pass allow on site maintenance operation on the UPS without interruption.
Distribution panel with IEC320 sockets. Available on the Mod-System only, allows the electrical distribution to be shared between various IEC320 sockets (the IT standard). This enables users to organize their electrical power supply from the UPS straight to the load.
* for availability and the delivery arrangements of this service in your area, please contact your authorized SOCOMEC SICON UPS representative.
16
MODULYS ® Technical data POWER Tecnology INPUT Nominal input voltage
1500VA/1050W
3000VA/2100W 4500VA/3150W VFI (Voltage and Frequency Independent) On line, double conversion
230V (1 ph) ± 20% (up to -30% @ 70% nominal load) 50/60Hz ± 10%
Frequency Power factor/THDI OUTPUT Output voltage (Vout) Output frequency (Fout) Automatic by-pass Overloads (mains mode) Efficiency AC/AC Crest factor STANDARDS Safety Performance & topology EMC standard Product certification Degree of protection ENVIRONMENTAL DATA Operating temperature
6000VA/4200W
230V (1 ph) or 400V (3 ph +N) ± 20% (up to -30% @ 70% nominal load) > 0.99/< 6%
230V (1 ph) ± 3% (settable for 208/220/240V) 50Hz or 60Hz ±2% (±0.1% in battery mode) Voltage selected ±15% - frequency selected ±2% (110% for one minute) (130% for 10 seconds) (200% for 5 cycles) 90% in On line mode 97% in ECO MODE 3:1 (EN) IEC 50091-1-1 (EN) IEC 62040-3 EN 50091-2 (level B)
EN 50091-2 (level A) CE IP 21 (complying with IEC 60529)
Relative humidity Maximum altitude (above see level) Acoustic noise (ISO 3746) Heat dissipation Watt / (BTU/hr) @ 100% load DIMENSIONS weight (batteries included) Dimensions (WxDxH) weight Mod-Tower Dimensions (WxDxH) weight Mod-Rack Dimensions (WxDxH) weight Mod-Power Mod-Tower / Mod-Rack CONNECTIONS Input Seperate auxiliary mains input Output Power share socket
0 +40°C (32-104°F); for best battery life from 15°C to 25°C (from 59°F to 77°F) 0 - 90% non-condensing 1000mt (3,300ft) without derating (maximum 3,000mt - 10,000ft) <50dB @ 1mt <52dB @ 1mt 260/(887) 350/(1195)
<45dB @ 1mt 145/(495)
131x460x450mm / 23kg 131x460x450mm / 35kg 3U - depth 460mm / 35kg 3U - depth 461mm / 31kg
2x(131x540x450mm) / 57kg 2x3U - depth 540mm / 57kg 2x3U - depth 461mm / 52kg
IEC 320 C20 (16A) N.A. IEC 320 C19 (16A) IEC 320 C13 (10A)
BACK-UP EXPANDABLE UP TO standard maximum in power in back-up VA min. min. VA min. 3000 8 65* 4500 8 52* 6000 8 35* 3000 8 65* 4500 8 52* 6000 8 35* 1500 8 120 4500 25 3000 8 65 9000 8 1500 8 180 6000 25 3000 8 110 6000 40 4500 8 100 13500 12 6000 8 65 12000 23 6000 8 65 18000 12 6000 8 100 12000 40 9000 8 60 18000 18 12000 8 40 24000 12 9000 8 100 18000 30 12000 8 65 24000 23 4500 60 160 4500 550* 6000 45 110 6000 410* 3000 110 420 3000 1200* 4500 60 270 4500 630* 6000 45 190 6000 480* 6000 110 / 9000 550* 9000 70 / 9000 330* Standards items / Accessories ( = standard, = optional) RS232/485 serial interface*** Relays for signalling contacts (4 contacts) Slots for comunication boards Dry contacts relay card (3 contacts) Advanced communication card NET VISION / Web/SNMP manager LCD Remote mimic panel Separate input for AUX mains (by-pass line) Galvanic isolation transformer Temperature sensor
520/(1774)
2x(131x540x450mm) / 65 kg 2x3U - depth 540mm / 65kg 2x3U - depth 461mm / 65kg
Terminals Terminals Terminals IEC 320 C13 (10A) Back-up @ 75% of load. Expansions of power and back-up for Mod-System in a single cabinet.
Stand alone
Mod-TW 30 Mod-TW 45 Mod-TW 60 Mod-RK 30 Mod-RK 45 Mod-RK 60 Mod-System Mod-RM 315 Mod-RM 330 Mod-MC 415 Mod-MC 430 Mod-MC 645 Mod-MC 660 Mod-MC 660 six Mod-MC 960 Mod-MC 990 Mod-MC 912 six Mod-EB 1290 Mod-EB 1212 six Mod-EM 245 Mod-EM 260 Mod-TC 230 Mod-TC 245 Mod-TC 260 Mod-TC 360 Mod-TC 390
-1
1
-** -**
-**
-
2
2
2
2
2
2
2
2
-
2
-
-
2
2
-
-
-
-
-
MODELS Frame
Mod-RM 3XX 3 slots
Mod-MC 4XX 4 slots
Mod-MC 6XX 6 slots
Mod-MC 9XX 9 slots
Mod-EB 12XX 12 slots
Mod-EM 2XX specific
Mod-TC 2XX specific
Mod-TC 3XX specific
Dimensions (WxDxH)(mm)
19”x550x12U
550x625x760
550x625x1026
550x625x1425
550x625x1824
600x600x1425
600x600x1425
600x600x1425
7200
4000
ENVIROMENTAL DATA Acoustic noise Heat dissipation max (BTU/hr)
52dB @ 1 mt 2700
60dB @ 1 mt 1800
5400
7200
55dB @ 1 mt
60dB @ 1 mt 4000
* Autonomy achievable with additional cabinets including battery charger. ** Available only on Mod-TW 45/60 and Mod-RK 45/60. *** RS485 available on 4500, 6000 VA and Mod-System.
5000
IN EUROPE
IN ASIA
BELGIUM
INDIA
Schaatsstraat, 30 rue du Patinage B - 1190 Bruxelles Tel. +32 (0)2 340 02 34 - Fax +32 (0)2 346 16 69
[email protected]
Atma Ram Mansion 1/21 Asaf Ali Road IN - New Dehli - 110 002 Tel. +91 11 23234411 - Fax +91 1123232639
[email protected]
FRANCE 95, rue Pierre Grange F - 94132 Fontenay-sous-Bois Cedex Tel. +33 (0)1 45 14 63 90 - Fax +33 (0)1 48 77 31 12
[email protected]
GERMANY Heppenheimerstraße 57 D - 68309 Mannheim Tel. +49 (0) 621 7168 40 - Fax +49 (0) 621 7168 444
[email protected]
ITALY Viale Tolstoi, 73 - Zivido 20098 San Giuliano Milanese (MI) Tel. +39 02 98 242 942 - Fax +39 02 98 240 723
[email protected]
SINGAPORE 25 Tagore Lane, # 01-02 Singapore Godown SG - 787 602 Singapore Tel. +65 6 554-0900 - Fax +65 6 458-7377
[email protected]
COUV 108 A
Socomec Sicon UPS worldwide:
THAILAND 17/178 Prachachuen Road Tungsonghong, Laksi TH - 10210 Bangkok Tel. +66 2 503 92 43 - Fax +66 2 503 99 23
[email protected]
NETHERLANDS Bergveste 2F NL - 3992De Houten Tel. +31 (0)30 63 71 504 - Fax +31 (0)30 63 72 166
[email protected]
SLOVENIA Savlje 89 SI - 1000 Ljubljana Tel. +386 1 5807 860 - Fax +386 1 5611 173
[email protected]
SPAIN C/Nord, 22 Pol. Ind. Buvisa E - 08329 Teià (Barcelona) Tel. +34 93540 7575 - Fax +34 93540 7576
[email protected] Units 401/402 Cirencester Business Park Love Lane Cirencester Gloucestershire GL7 1YG Tel. +44 1285 644 444 - Fax +44 1285 644 414
[email protected]
HEAD OFFICE SOCOMEC GROUP SWITCHING PROTECTION AND UPS S.A. capital 10 923 800 € - R.C. Strasbourg 548500 149 B SOCOMEC SICON UPS Strasbourg 11, route de Strasbourg - B.P. 50 - F-67230 Huttenheim - FRANCE Tel. +33 (0)3 88 57 45 45 - Fax +33 (0)3 88 74 07 90
[email protected] SOCOMEC SICON UPS Vicenza Via della Tecnica, 1 - I - 36030 Villaverla - ITALIE Tel. +39 0445 359 111 - Fax +39 0445 359 222
[email protected]
www.socomec-sicon.com
SITES EN FRANCE
SITES EN ITALIE
ISO 9001: 2000 FM 28237
This document is not a specification. SOCOMEC SICON UPS reserves the right to make any changes to data without prior notice.
SALES AND MARKETING MANAGEMENT SOCOMEC SICON UPS Paris 95, rue Pierre Grange F-94132 Fontenay-sous-Bois Cedex - FRANCE Tel. +33 (0)1 45 14 63 90 Fax +33 (0)1 48 77 31 12
[email protected]
Réf. DOC 34093 - 09/04 - Photos : Martin Bernhart - Réalisation : SOCOMEC Service Communication
UNITED KINGDOM