Preview only show first 10 pages with watermark. For full document please download

Molex

   EMBED


Share

Transcript

InfiniBand FDR/EDR I/O’s Up to 2 .5 x the Data Rate Jay Neer Strategic g Product Manager g Industry Standards Molex Backwards Compatible Copper & Optical Next Generation InfiniBand I/O Connectors -An overview of the new connector solutions that enable InfiniBand to more than double its data rate while maintaining backwards compatibility. compatibility. - InfiniBand is capitalizing on the highest data rate, rate, highest density, multi multi--purpose I/O’s to provide high performance, performance, flexible solutions to providers and end users. InfiniBand Road Map Latest Rev InfiniBand FDR & EDR Interconnect Road Map Overview - Both 4x & 12x InfiniBand I/O’s are replaced with new enhanced I/O solutions that enable up to 2.5x the data rate for both direct attach copper and optical cabling solutions - Breakout cables provide transitions between 12x and 4x ports. - Adapter cables enable connection back to SDR/DDR/QDR systems. Multiple Sourcing Strategy • Molex and Tyco Electronics have joined to provide next-generation next generation I/O solutions to the connector marketplace. • The 4 channel zQSFP and 12 channel zCXP are a part of that agreement. • Molex and TE will bring these products to market, and support continuing development of the SI, EMI and Thermal solutions required • Molex and TE will offer RAND terms as required zQSFP+ I/O - 4 Channel, 25Gbps/Channel 4 x 25 = 100Gbps Current QDR Ecosystem Shipping: -Single SMT Connector -Single Cage -Ganged Ganged Cages -Stacked, Ganged Cages -Light Pipe Options -Thermal Options -EMI Solution Options -Direct Attach Copper Cables -Copper SFP+ Breakout Cables -Copper Loopbacks -12 12 Fiber MTP Optical Cables -Optical LC Breakout Cables -Optical Loopbacks zQSFP+ Family of Products - 10G/QDR - SFF-8436 - QSFP+ - InfiniBand Architecture Annex 5, Also Ethernet IEEE 802.3ba and SAS 2.1 New zQSFP+ 25G/EDR Specifications: SFF-8661, 8662, 8663 Integrated Stacked & Ganged Connector Solutions Optical Loopback Single and Ganged Cages - Belly to Belly Solutions Optional Cage with Solid Top Optional Heat Sink & Light Pipe Solutions Active Optical Cable 38 ckt iPassTM Connector (same as PCI Express 4x) Passive Optical Cable Pluggable Optical Module Copper Loopback Gasket or Spring finger EMI Solutions Direct Attach Copper Cable Passive and Active zQSFP+ SMT Connector • • • • • • Same mating interface = backwards compatible to existing QSFP+ cable solutions Same PCB SMT pad geometry as QSFP+ Connector and cage depth dimension increased by 2.2mm – enables insert molded wafer solution top and bottom. Support for single, ganged, and belly to belly applications Stacked versions are also possible, QDR QSFP+ style now available Fi ld proven - leverages Field l manufacturing f t i experience i f from QDR QSFP+ QSFP Insert Molded Arrays zQSFP+ Cabling Solutions zQSFP to zQSFP zQSFP+ zQSFP+ 4 x 10Gb/s = 40Gb/s - Industry standard 12 fiber MTP connector - Round bulk cable - improved cable management within a rack - 3mm diameter cable for short runs - 4.5mm diameter for runs up to 25 meters - Utilizes exterior 4 fibers on each side of a 12 fiber ribbon cable; zCXP to zQSFP+ 12 x 10Gb/s > (3) 40Gb/s zQSFP+ Performance zQSFP+ IBTA specification RFP Objective Molex /TE zQSFP+ SMT IL -1.4dB @ 14GHz -0.9dB RL -12dB up to 14GHz -14dB CM conversion -24dB up to 14GHz -40dB ICN 3mV 1.6mV MDNEXT 1mV (rms) 0.5mV MDFEXT 2 8 V (rms) 2.8mV ( ) 15 V 1.5mV zQSFP+ Development / Compliance / Test Boards - Module Compliance Board (MCB) - (1) Req’d if testing with Loopbacks - (2) Req’d if testing with Cables - Host Compliance p Board ((HCB)) zQSFP+ Comparison to IBTA RFP RFP Requirement Legacy Inter-mate Data Rate Interface Width Contact Reliability Thermal management Width – 21/22mm pitch Height g – 18mm w/HS / Depth – 80mm Robustness Belly to Belly zQSFP+ Molex/TE Yes Yes – based on simulation 38 Ckt – current QSFP+ Same as current product Yes – see zCXP Conforms – 19mm to 21mm Conforms – 9.76mm cage g Conforms – 60.8 mm overall Same as current product Yes zQSFP+ Form Factor Applications Mellanox HBA’s Shown zQSFP+ Form Factor Applications Mellanox Switches Shown zCXP+ I/O - 12 Channel, 25Gbps/Channel 12 x 25 = 300Gbps • InfiniBand Architecture Annex 6 • FDR/14Gbps & EDR/25Gbps Infrastructure remains backwards plug compatible with the current 10G infrastructure Current QDR Ecosystem Shipping: - Single Integrated Connector - Single Integrated B2B Connector - Single Integrated Stacked (2x1) Connector - Single Vertical Integrated Connector - 12x Optical p Pluggable gg Modules - Light Pipe Options - Thermal Solution Options - EMI Solution Options - Passive & Active 12x Copper Cables - Copper & Optical QSFP+ Breakout Cables - Copper & Optical SFP+ Breakout Cables -Copper & Optical Loopbacks - 24 Fiber MTP Optical Cables zCXP Family of Products Passive & Active Copper Cables - 12x CXP to 12x CXP - 12x CXP to (3) 4x QSFP+ - 12x CXP to (3) 4x MicroGiga 84 Contact iPass+TM Integrated Connector - Press-fit pins to system board - Integrated Guide / Cage - ((4)) screws attach Guide to Board from the bottom Pull to Release De-Latching Thermal Solutions - Application Specific Optical Pluggable Modules & Cables - Standard MPO Optical Connectors - 12x CXP to 12x CXP - 12x CXp p to (3) ( ) 4x QSFP+ Q - 2x12 Standard MPO Ribbon Cable zCXP Compliant Pin Connector Single Port w/out Top Cover Die cast floor created in zCXP to enable lower thermal heatsink (not shown) Access area to Top and Bottom of Plug Clip-on Cover w/vent holes Standard Heat Sinks Optional & Application Dependent - Can be extended to the rear or to the sides - Can be square or round pins or fins - Heights g based on application pp zCXP Belly 2 Belly Solution Connector C t llength th extended t d d tto provide id clearance l ffor th the second footprint in-line behind the standard footprint Design enables heat sinks on top of both connectors, optimizes thermal design and panel density 55 22 55.22 75 22 75.22 zCXP Copper Cables Passive & Active Solutions CXP / CXP (1) 12x cable (2) 6x cables (3) 4x cables zCXP Optical Cables & Pluggable Modules Active Solutions zCXP / zCXP Active Optical Cables Pluggable Optical Module w/ Passive Optical Cable Assembly CXP / QSFP Breakout zCXP Performance zCXP IBTA specification IL RL CM conversion Requirement -1.4dB @ 14GHz -12dB up to 14GHz -24dB up to 14GHz Molex/TE zCXP -1.2 dB -12 dB -28 dB ICN MDNEXT MDFEXT 3mV 1mV (rms) 2.8mV (rms) 3.6 mV 2.6 mV 2.6 mV zCXP Thermal Analysis - Dual Heat Sink - zCXP p provides for additional lower heatsink • 6 watts transferred at 700 lfm with 15 15.0 0 Degree C rise • Interface modeled with 10% line-to-line (0 gap) - 0.05 gap remaining area zCXP Development / Compliance / Test Boards MCB - Module Compliance Board (MCB) - (1) Req’d if testing with HCB - (2) Req’d if testing with Cables HCB - - Host Compliance Board (HCB) zCXP Comparison to IBTA RFP RFP Requirement R i t Legacy Inter-mate Data Rate Interface Width Contact Reliability Thermal management Width –27 mm pitch Height – 18mm (with heat sink) Depth – 80mm Robustness Belly to Belly zCXP CXP Yes Yes – based on simulation 84 Ckt, same as current CXP Same as current product Yes Conforms – 27 mm, single Conforms – 11.7 mm cage Conforms – 53.22 mm overall Same as current product Yes zCXP Application/Density Overview Supports both Copper & Optical Solutions Line Card / 1U Solutions Single Integrated Connectors (16) Ports /side Standard PCI Card ((3)) Ports 16 12 8 16x/12x/8x Wide Integrated Connectors Single Vertical Integrated Connector (16) Ports/row Belly-to-Belly Integrated Connectors (16) Ports /side 32 ports total Blades Integrated Connectors (8) Ports/side (16) Ports total Stacked Integrated Connectors (32) Ports one side Voltaire Director Level Hardware CXP Front I/O’s QSFP R QSFP+ Rear I/O’ I/O’s Oracle Super Computer Cabled Demo - Cable Management - Very Important for Large Installations InfiniBand - The Highest Density I/O Solutions Bandwidth RJ-45 48 Channels 480 Gb/s SFP+ 48 Channels 480 Gb/s SFP+ 48 Channels SFP Ch l 480 Gb/s MicroGiga 112 Ch. 1120Gb/s iPass 128 Channels 1280 Gb/s zQSFP+ 144 Channels 3600 Gb/s MicroGiga – 192 Ch. 960 Gb/s zCXP – 384 Channels 9600 Gb/s