Transcript
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
Most I & T Corporation Solid State Disk JM series Product Specification V1.0
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 1
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
Contents: 1.
Product Information ......................................................... 3
2.
System Features .............................................................. 3
3.
Specifications ................................................................... 3
4.
Block Diagram .................................................................. 5
5.
Pin Assignments .............................................................. 5 5.1. 5.2.
Serial ATA ................................................................................................. 5 Mini USB................................................................................................... 6
6.
Dimension ......................................................................... 7
7.
Electrical Specifications .................................................. 8 7.1. 7.2. 7.3. 7.4. 7.5. 7.6. 7.7.
Absolute Maximum Rating ..................................................................... 8 Recommended Power Supply Operation Conditions ........................... 8 Power Supply DC Characteristics (SATA Idle Mode) .......................... 9 Recommended Power Supply Operation Conditions ........................... 9 Recommended External Clock Source Conditions ............................... 9 Power Supply DC Characteristics (SATA Idle mode)........................ 10 I/O DC Characteristics .......................................................................... 10
8.
Command Descriptions ................................................. 10
9.
Barcode Description ...................................................... 22
10.
Order Information ........................................................... 22
11.
Part Number Decoder .................................................... 23
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 2
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
1. Product Information The Solid State Disk is a single chip, interface include Serial ATA (7+15pins) port and Mini USB. Data swap between different Interfaces can be done very efficiency by DMA without CPU involvement. Based on the efficient architecture, The Afaya JM series Solid State Disk can provide the best performance. It is provide higher bandwidth for flash memory access. It also provides the embedded hardware error correction code (ECC), wear leveling, and bad block management technology in the chip.
2. System Features
Fully compatible with devices and OS that support the SATAⅡ 3.0Gbps standard Supports BCH ECC 8 bits or 15bits in 512 bytes.
Max Capacity supported: 256GByte. Integrated 1-port USB2.0, 1-port SATA II and 8-channel Flash controller. Reliable wear-leveling algorithm to ensure the best of flash endurance. Auto Standby and Sleep Mode supported. Supports dynamic power management. Capacity supported: 32GB、64GB、128GB and 256GB(unformatted).
3. Specifications Compatibility
Serial ATA 2.0 Specification
Flash Technology NAND Type Flash Memory Base Form Factor
Horizontal Type in Rightwards
Connector Types
Standard 7+15pins female Serial ATA connector Standard Mini 5-pin female USB connector
System Performance Data Transfer Mode Sequential Read
Serial ATA
Mini USB
SLC Type
170 Mbytes/sec Max.
30 Mbytes/sec Max.
MLC Type
145 Mbytes/sec Max.
30 Mbytes/sec Max.
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 3
盛光科技股份有限公司 Most I & T Corporation Sequential Write Access Time
SUD-25JM Specification
SLC Type
140 Mbytes/sec Max.
25 Mbytes/sec Max.
MLC Type
90 Mbytes/sec Max.
25 Mbytes/sec Max.
0.2ms
Environmental Specification Standard Temperature Wide Temperature Vibration
Operation
0ºC ~ +70ºC
Non-operation
-20ºC ~ +80ºC
Operation
-40ºC ~ +85ºC
Non-operation
-50ºC ~ +95ºC
Operation max
20 G
Non-operation max
20 G
Humidity
5~95% non-condensing
Shock
1500 G
Reliability MTBF
> 1,000,000 hours
Error Correction Code
BCH8 can correct up to 8 random error bits within 512 data bytes.
Endurance(SLC)
Greater than 1,000,000 cycles logically contributed by Wear-leveling and advanced bad sector management algorithms
Endurance(MLC)
Greater than 100,000 cycles logically contributed by Wear-leveling and advanced bad sector management algorithms
Data Reliability
< 1 non-recoverable error in 1014 bits read
Data Retention
10 years
Power Consumption Power Voltage
+5V ± 10%
Read
550mA
Write
500mA
Sleep Mode
210mA
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 4
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
4. Block Diagram
5. Pin Assignments
Power Segment
Signal Segment
5.1. Serial ATA Pin Name Number
Type
S1
GND
2nd mate
S2
A+
S3
A-
S4
GND
S5
B-
S6
B+
S7
GND
2nd mate
P1
V33
3.3 V power
P2
V33
3.3 V power
P3
V33
3.3 V power, pre-charge, 2nd mate
P4
GND
1st mate
P5
GND
2nd mate
Differential signal pair A 2nd mate Differential signal pair B
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 5
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
P6
GND
2nd mate
P7
V5
5 V power, pre-charge, 2nd mate
P8
V5
5 V power
P9
V5
5 V power
P10
GND
2nd mate
P11
1. The pin corresponding to P11 in the backplane receptacle connector is also reserved Reserved 2. The corresponding pin to be mated with P11 in the power cable receptacle connector shall always be grounded
P12
GND
1st mate
P13
V12
12 V power, pre-charge, 2nd mate
P14
V12
12 V power
P15
V12
12 V power
5.2. Mini USB Pin Number
Name
1
VCC
2
D-
3
D+
4
ID
5
Type POWER The pairs are used to transmit Address, Data and Command.
GND Ground
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 6
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
Note: The comments on the mating sequence in forward table apply to the case of backplane blind mate connector only. In this case, the mating sequences are: (1) The pre-charge power pins and the other ground pins (2) The signal pins and the rest of the power pins.
6. Dimension
2.5 inch Form Factor Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 7
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
7. Electrical Specifications 7.1. Absolute Maximum Rating Symbol
Parameter
Condition MIN TYP
MAX
Unit
AVDDH
Analog power supply
-0.5
6
V
DVDD
Digital I/O power supply
-0.5
6
V
-0.4
DVDD+0.4 V
-55
140
VI(D)
Digital I/O input voltage
TSTORAGE Storage temperature
℃
7.2. Recommended Power Supply Operation Conditions Symbol PV33 D1V8
Parameter
Condition
Operation digital power supply
ASV33 ASV18
Operation analog power supply
AVDDH
MIN TYP MAX Unit 3.0
3.3
3.6
V
1.85
1.9
2.0
V
3.0
3.3
3.6
V
1.85
1.9
2.0
V
3.0
3.3
3.6
V
TA
Ambient operation temperature
For commercial spec.
0
70
℃
TA
Ambient operation temperature
For industry spec
-40
85
℃
TJ
Junction temperature
0
125
℃
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 8
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
7.3. Power Supply DC Characteristics (SATA Idle Mode) Parameter
Symbol
Min
Max
Unit
AVDDH
-0.5
6
V
Digital I/O power supply
DVDD
-0.5
6
V
Digital I/O input voltage
VI(D)
-0.4
DVDD+0.4
V
TSTORAGE
-55
140
℃
Analog power supply
Storage temperature
Condition
7.4. Recommended Power Supply Operation Conditions Parameter
Symbol
Operation digital power supply
Operation analog power supply
Condition
Min
Typica Ma Uni l x t
PV33
3
3.3
3.6
V
D1V8
1.85
1.9
2
V
ASV33
3
3.3
3.6
V
ASV18
0
70
V
AVDD H
-40
85
V
Ambient operation temperature
TA
For commercial spec.
Ambient operation temperature
TA
For industry spec.
Junction temperature
TJ
125 ℃
0
℃ ℃
7.5. Recommended External Clock Source Conditions Parameter
Symbol Condition
Min
External reference clock
Typical
Max
30
Clock Duty Cycle
45
50
Unit MHZ
55
%
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 9
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
7.6. Power Supply DC Characteristics (SATA Idle mode) Parameter
Symbol Condition
Typical Max
Unit
IPV33
3.3V
6
ma
IDV18
1.9V
94
ma
IAVDDH
3.3V
34
ma
IASV33
3.3V
2
ma
IASV18
1.9V
120
ma
Digital power supply USB Analog Power Supply
Min
SATA Analog Power Supply
7.7. I/O DC Characteristics Parameter
Symbol Condition
Min
Typical
Max
Unit
Input low voltage
VIL
0.8
V
Input high voltage
VIH
2
Output low voltage
VOL
0
0.4
V
Output high voltage
VOH
2.6
3.6
V
V
8. Command Descriptions This table with the following paragraphs summarizes the ATA command set.
Command Table PARAMETERS USED
Command Name
Code
CHECK POWER MODE
E5h
X
X
X
O
X
X
EXECUTE DIAGNOSTICS
90h
X
X
X
O
X
X
FLUSH CACHE
E7h
X
X
X
O
O
X
IDENTIFY DEVICE
Ech
X
X
X
O
X
X
IDLE
E3h
O
X
X
O
X
X
IDLE IMMEDIATE
E1h
X
X
X
O
X
X
INITIALIZE DEVICE PARAMETERS
91h
O
X
X
O
O
X
C8h or C9h O
O
O
O
O
X
READ DMA
SC SN CY DR
HD FT
READ MULTIPLE
C4h
O
O
O
O
O
X
READ SECTOR(S)
20h or 21h
O
O
O
O
O
X
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 10
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
READ VERIFY SECTOR(S)
40h or 41h
O
O
O
O
O
X
RECALIBRATE
10h
X
X
X
O
X
X
SECURITY DISABLE PASSWORD
F6h
X
X
X
O
X
X
SECURITY ERASE PREPARE
F3h
X
X
X
O
X
X
SECURITY ERASE UNIT
F4h
X
X
X
O
X
X
SECURITY FREEZE LOCK
F5h
X
X
X
O
X
X
SECURITY SET PASSWORD
F1h
X
X
X
O
X
X
SECURITY UNLOCK
F2h
X
X
X
O
X
X
SEEK
7xh
X
X
O
O
O
X
SET FEATURES
Efh
O
X
X
O
X
O
SET MULTIPLE MODE
C6h
O
X
X
O
X
X
SLEEP
E6h
X
X
X
O
X
X
SMART
B0h
X
X
O
O
X
O
STANDBY
E2h
X
X
X
O
X
X
STANDBY IMMEDIATE
E0h
X
X
X
O
X
X
CAh or CBh O
O
O
O
O
X
WRITE DMA WRITE MULTIPLE
C5h
O
O
O
O
O
X
WRITE SECTOR(S)
30h or 31h
O
O
O
O
O
X
Note: O = Valid, X = Don't care SC = Sector Count Register SN = Sector Number Register CY = Cylinder Low/High Register DR = DEVICE SELECT Bit (DEVICE/HEAD Register Bit 4) HD = HEAD SELECT Bit (DEVICE/HEAD Register Bit 3-0) FT = Features Register Word
Value
F/V Description General configuration bit-significant information:
0
1
0040h
F
15
X
14-8 Retired
F
7
X
6 Obsolete
X
5-3 Retired
F
2 Reserved
X
1 Retired
F
0 Reserved
XXXXh X
0 = ATA device 1 = removable media device
Number of logical cylinders
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 11
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
2
C837h
V
Specific configuration
3
00XXh
X
Number of logical heads
4-5
XXXXh X
Retired
6
XXXXh X
Number of logical sector per logical track
7-8
XXXXh V
9
000Eh
10-19
XXXXh F
Serial number (20 ASCII characters)
20-21
XXXXh X
Retired
22
003Fh
Obsolete
23-26
XXXXh F
Firmware revision (8 ASCII characters)
27-46
XXXXh F
Model number (40 ASCII characters)
47
8000h
X
X
Reserved for assignment by the CompactFlash_ Association Retired
F
15-8 80h
F
7-0 00h = Reserved
F
01h = Maximum number of 1 sectors on READ/WRITE MULTIPLE commands
48
4000h
F
Reserved Capabilities
F
15-14 Reserved for the IDENTIFY PACKET DEVICE command.
F
13
1 = Standby timer values as specified in this standard
are supported 0 = Standby timer values shall be managed by the device 49
2F00h
F
12 Reserved for the IDENTIFY PACKET DEVICE command.
F
11
1 = IORDY supported 0 = IORDY may be supported
F
10
1 = IORDY may be disabled
F
9
1 = LBA supported
F
8
1 = DMA supported.
X
7-0 Retired Capabilities
50
4000h
F
15 Shall be cleared to zero.
F
14 Shall be set to one.
F
13-2 Reserved.
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 12
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
X
1
Obsolete
F
0
Shall be set to one to indicate a device specific Standby
timer value minimum. 51
0280h
X
15-8 PIO data transfer cycle timing mode 7-0 Reserved
52
0000h
X
Obsolete
F
15-3 Reserved
F
2
1 = the fields reported in word 88 are valid 0 = the fields reported in word 88 are not valid
53
0007h
F
1
1 = the fields reported in words 70:64 are valid 0 = the fields reported in words 70:64 are not valid
X
0
1 = the fields reported in words 58:54 are valid 0 = the fields reported in words 58:54 are not valid
54
XXXXh X
Number of current cylinders
55
00XXh
Number of current heads
56
XXXXh X
Number of current sector per track
57-58
XXXXh X
Current capacity in sectors
59
0000h
60-61
XXXXh F
Total number of user addressable sectors
62
0000h
X
Obsolete
F
15-11 Reserved
V
10
X
F
15-9 Reserved
V
8 1 = Multiple sector setting is valid
0 = Multiword DMA mode 2 is not selected
V V
9
0007h
F
8
0003h
65
0078h
1 = Multiword DMA mode 0 is selected 0 = Multiword DMA mode 0 is not selected
F
64
1 = Multiword DMA mode 1 is selected 0 = Multiword DMA mode 1 is not selected
F 63
1 = Multiword DMA mode 2 is selected
F
7-3 Reserved
F
2
1 = Multiword DMA mode 2 and below are supported
F
1
1 = Multiword DMA mode 1 and below are supported
F
0
1 = Multiword DMA mode 0 is supported
F
15-8 Reserved
F
7-0 Advanced PIO modes supported
F
Minimum Multiword DMA transfer cycle time per word
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 13
盛光科技股份有限公司 Most I & T Corporation 66
0078h
F
67
0078h
F
68
0078h
F
69-79
0000h
F
SUD-25JM Specification
Manufacturer’s recommended Multiword DMA transfer cycle time Minimum PIO transfer cycle time without flow control Minimum PIO transfer cycle time with IORDY flow control Reserved (for future command overlap and queuing) Major version number 0000h or FFFFh = device does not report version
80
81
01FEh
0021h
F
15
Reserved
F
14
Reserved for ATA/ATAPI-14
F
13
Reserved for ATA/ATAPI-13
F
12
Reserved for ATA/ATAPI-12
F
11
Reserved for ATA/ATAPI-11
F
10
Reserved for ATA/ATAPI-10
F
9
Reserved for ATA/ATAPI-9
F
8
Reserved for ATA/ATAPI-8
F
7
1 = supports ATA/ATAPI-7
F
6
1 = supports ATA/ATAPI-6
F
5
1 = supports ATA/ATAPI-5
F
4
1 = supports ATA/ATAPI-4
F
3
Obsolete
X
2
Obsolete
X
1
Obsolete
F
0
Reserved
F
Minor version number Command set supported.
82
0068h
X
15
Obsolete
F
14
1 = NOP command supported
F
13
1 = READ BUFFER command supported
F
12
1 = WRITE BUFFER command supported
F
11
Obsolete
F
10
1 = Host Protected Area feature set supported
F
9
1 = DEVICE RESET command supported
F
8
1 = SERVICE interrupt supported
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 14
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
F
7
1 = release interrupt supported
F
6
1 = look-ahead supported
F
5
1 = write cache supported
F
4
Shall be cleared to zero to indicate that the PACKET Command feature set is not supported.
F
3
1 = mandatory Power Management feature set supported
F
2
1 = Removable Media feature set supported
F
1
1 = Security Mode feature set supported
F
0
1 = SMART feature set supported
Command sets supported.
83
5000h
F
15 Shall be cleared to zero
F
14 Shall be set to one
F
13-9 Reserved
F
8
1 = SET MAX security extension supported
F
7
Reserved
F
6
1 = SET FEATURES subcommand required to spinup after power-up
F
5
1 = Power-Up In Standby feature set supported
F
4
1 = Removable Media Status Notification feature set supported
F
3
1 = Advanced Power Management feature set supported
F
2
1 = CFA feature set supported
F
1
1 = READ/WRITE DMA QUEUED supported
F
0
1 = DOWNLOAD MICROCODE command supported
Command set/feature supported extension.
84
85
4000h
0008h
F
15 Shall be cleared to zero
F
14 Shall be set to one
F
13-2 Reserved
F
1
1 = SMART self-test supported
F
0
1 = SMART error logging supported
X
Command set/feature enabled.
F
15 Obsolete
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 15
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
F
14
1 = NOP command enabled
F
13
1 = READ BUFFER command enabled
F
12
1 = WRITE BUFFER command enabled
X
11
Obsolete
V
10
1 = Host Protected Area feature set enabled
F
9
1 = DEVICE RESET command enabled
V
8
1 = SERVICE interrupt enabled
V
7
1 = release interrupt enabled
V
6
1 = look-ahead enabled
V
5
1 = write cache enabled
F
4
Shall be cleared to zero to indicate that the PACKET Command feature set is not supported.
F
3
1 = Power Management feature set enabled
F
2
1 = Removable Media feature set enabled
V
1
1 = Security Mode feature set enabled
V
0
1 = SMART feature set enabled
Command set/feature enabled. F
15-9
F
8
Reserved
1 = SET MAX security extension enabled by SET MAX SET PASSWORD
F
7
See Address Offset Reserved Area Boot, INCITS TR27:2001
86
5000h
F
6
1 = SET FEATURES subcommand required to spin-up after power-up
V
5
1 = Power-Up In Standby feature set enabled
V
4
1 = Removable Media Status Notification feature set enabled
V
3-1
1 = Advanced Power Management feature set enabled
F
0
1 = DOWNLOAD MICROCODE command supported
Command set/feature default. 87
4000h
F
15 Shall be cleared to zero
F
14 Shall be set to one
F
13-2 Reserved
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 16
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
F
1
1 = SMART self-test supported
F
0
1 = SMART error logging supported
V
15-13
V
12
Reserved
1 = Ultra DMA mode 4 is selected 0 = Ultra DMA mode 4 is not selected
V
11
1 = Ultra DMA mode 3 is selected 0 = Ultra DMA mode 3 is not selected
V
10
1 = Ultra DMA mode 2 is selected 0 = Ultra DMA mode 2 is not selected
F 88
9
1 = Ultra DMA mode 1 is selected 0 = Ultra DMA mode 1 is not selected
203Fh F
8
1 = Ultra DMA mode 0 is selected 0 = Ultra DMA mode 0 is not selected
F
7-5
Reserved
F
4
1 = Ultra DMA mode 4 and below are supported
F
3
1 = Ultra DMA mode3 and below are supported
F
2
1 = Ultra DMA mode 2 and below are supported
F
1
1 = Ultra DMA mode 1 and below are supported
F
0
1 = Ultra DMA mode 0 is supported
89
0000h
F
Time required for security erase unit completion
90
0000h
F
Time required for Enhanced security erase completion
91
0000h
V
Current advanced power management value
92
0000h
V
Master Password Revision Code
93
0000h
X
Hardware reset result
94-126
0000h
V
Reserved Removable Media Status Notification feature set support
127
0000h
F
15-2 Reserved
F
1-0
00 = Removable Media Status Notification feature set not supported 01 = Removable Media Status Notification feature supported 10 = Reserved 11 = Reserved
128
0001h
Security status
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 17
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
129-159
0000h
X
Vendor specific
160-254
0000h
X
Reserved
255
0000h
X
Integrity word 15-8 Checksum 7-0 Signature
Key: F/V = Fixed/variable content F = the content of the word is fixed and does not change. For removable media devices, these values may change when media is removed or changed. V = the contents of the word is X = the content of the word may be fixed or variable.
IDLE (E3h) This command causes the device to set BSY, enter the Idle mode, clear BSY and generate an interrupt. If sector count is non-zero, the automatic power down mode is enabled. If the sector count is zero, the automatic power mode is disabled. IDLE IMMEDIATE (E1h) This command causes the device to set BSY, enter the Idle(Read) mode, clear BSY and generate an interrupt. INITIALIZE DEVICE PARAMETERS (91h) This command enables the host to set the number of sectors per track and the number of tracks per heads. READ DMA (C8h) Reads data from sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value. A sector count of zero requests 256 sectors. READ MULTIPLE (C4h) This command performs similarly to the Read Sectors command. Interrupts are not generated on each sector, but on the transfer of a block which contains the number of sectors defined by a Set Multiple command. READ SECTOR(S) (20h/21h) This command reads 1 to 256 sectors as specified in the Sector Count register from sectors which is set by Sector number register. A sector count of 0 requests 256 sectors. The transfer beings specified in the Sector Number register. Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 18
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
READ VERIFY SECTOR(S) (40h/41h) This command verifies one or more sectors on the drive by transferring data from the flash media to the data buffer in the drive and verifying that the ECC is correct. This command is identical to the Read Sectors command, except that DRQ is never set and no data is transferred to the host. RECALIBRATE (10h) The current drive performs no processing if it receives this command. It is supported for backward compatibility with previousdevices. SECURITY DISABLE PASSWORD (F6h) Disables any previously set user password and cancels the lock. The host transfers 512 bytes of data, as shown in the following table, to the drive. The transferred data contains a user or master password, which the drive compares with the saved password. If they match, the drive cancels the lock. The master password is still saved. It is re-enabled by issuing the SECURITY SET PASSWORD command to re-set a user password. SECURITY ERASE PREPARE (F3h) This command shall be issued immediately before the Security Erase Unit command to enable erasing and unlocking. This command prevents accidental loss of data on the drive. SECURITY ERASE UNIT (F4h) The host uses this command to transfer 512 bytes of data, as shown in the following table, to the drive. The transferred data contains a user or master password, which the drive compares with the saved password. If they match, the drive deletes user data, disables the user password, and cancels the lock. The master password is still saved. It is re-enabled by issuing the SECURITY SET PASSWORD command to re-set a user password. SECURITY FREEZE LOCK (F5h) Causes the drive to enter Frozen mode. Once this command has been executed, the following commands to update a lock result in the Aborted Command error: • SECURITY SET PASSWORD Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 19
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
• SECURITY UNLOCK • SECURITY DISABLE PASSWORD • SECURITY ERASE PREPARE • SECURITY ERASE UNIT The drive exits from Frozen mode upon a power-off or hard reset. If the SECURITY FREEZE LOCK command is issued when the drive is placed in Frozen mode, the drive executes the command, staying in Frozen mode. SECURITY SET PASSWORD (F1h) This command set user password or master password. The host outputs sector data with PIO data-out protocol to indicate the information defined in the following table. SECURITY UNLOCK (F2h) This command disable LOCKED MODE of the device. This command transfers 512 bytes of data from the host with PIO data-out protocol. The following table defines the content of this information. SEEK (7xh) This command is effectively a NOP command to the device although it does perform a range check. SET FEATURES (EFh) This command set parameter to Features register and set drive’s operation. For transfer mode, parameter is set to Sector Count register. This command is used by the host to establish or select certain features. SET MULTIPLE MODE (C6h) This command enables the device to perform READ MULTIPLE and WRITE MULTIPLE operations and establishes the block count for these commands. SLEEP (E6h) This command causes the device to set BSY, enter the Sleep mode, clear BSY and generate an interrupt.
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 20
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
SMART Function Set (B0h) Performs different processing required for predicting device failures, according to the subcommand specified in the Features register. If the Features register contains an unsupported value, the Aborted Command error is returned. If the SMART function is disabled, any subcommand other than SMART ENABLE OPERATIONS results in the Aborted Command error. STANDBY (E2h) This command causes the device to set BSY, enter the Sleep mode (which corresponds to the ATA“Standby” Mode), clear BSY and return the interrupt immediately. STANDBY IMMEDIATE (E0h) This command causes the drive to set BSY, enter the Sleep mode (which corresponds to the ATA “Standby” Mode), clear BSY and return the interrupt immediately. WRITE DMA (CAh) Write data to sectors during Ultra DMA and Multiword DMA transfer. Use the SET FEATURES command to specify the mode value. WRITE MULTIPLE (C5h) This command is similar to the Write Sectors command. Interrupts are not presented on each sector, but on the transfer of a block which contains the number of sectors defined by Set Multiple command. WRITE SECTOR(S) (30h/31h) Write data to a specified number of sectors (1 to 256, as specified with the Sector Count register) from the specified address. Specify “00h” to write 256 sectors.
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 21
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
9. Barcode Description
S U D 2 5 J M 1 2 8 G B P C A 081112S Part Number Manufacturing Data: YYMMDD Flash Type: S: SLC Type M: MLC Type
10. Order Information Part Number Capacity
Standard Temperature
32GB
SUD-25JM32GBCFX1
64GB
SUD-25JM64GBCFX1
128GB
SUD-25JM128GBCFX1
256GB
SUD-25JM256GBCFX1
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 22
盛光科技股份有限公司 Most I & T Corporation
SUD-25JM Specification
11. Part Number Decoder X1X2X3-X4X5X6X7X8X9X10X11X12-X13X14X15 X1X2X3: Product Name SUD: SATA USB Flash Disk X4X5: Connector Position 25: 2.5 inch form factor X6X7: Controller Chip JM: JMicron -JM602 X8X9X10X11X12: Product Capacity 032GB: 32G Byte 064GB: 64G Byte 128GB: 128G Byte 256GB:256G Byte X13:Pb Y: Pb P: Pb free X14: Operation Temperature I: Wide Temperature(-40℃~+85℃) C: Standard Temperature(0℃~+70℃) X15: Disk Mode A: Auto Detect Disk Mode
Tel: +886-2-28085085 Fax: +886-2-28085080 URL: www.afaya.com.tw Address: 5F, No. 27-10, Sec. 2, Jungjeng E. Rd., Danshuei Jen, Taipei, Taiwan Page 23