Transcript
CHANNEL SAFETY SYSTEMS
t: 0845 884 7000 | w: www.channelsafety.co.uk
™
Security lighting range from Channel Safety Systems CHANNEL SAFETY SYSTEMS Petersfield Business Park Bedford Road Petersfield Hampshire GU32 3QA INSTRUCTION MANUAL - Issue 1 - 02/2014
t: 0845 884 7000 f: 0845 884 6000
e:
[email protected] w: www.channelsafety.co.uk
INSTRUCTION MANUAL
| 1
CHANNEL SAFETY SYSTEMS
t: 0845 884 7000 | w: www.channelsafety.co.uk
INSTRUCTIONS Each MotionPro Floodlight utilises passive infrared technology to detect heat radiation of moving objects such as people & vehicles. On activation the lamp will illuminate for a the chosen time period, an integral adjustable daylight sensor ensures night-only operation.
The MotionPro unit comes complete with:•
Luminaire c/w PIR Sensor unit.
•
Instruction manual. Please keep safe for future reference.
•
Accessory Pack.
Tools & Parts Needed For Installation •
Suitable drill & bits.
•
Terminal or Electricians screwdriver
•
Large slotted/Phillips screwdriver
•
Wire cutters/strippers
This product has glass front, care must be taken when installing or handling to prevent personal injury or damage to the unit. This light fitting must be installed by a competent person in accordance with the current building & IEE wiring regulations. Ensure that the electrical supply is correctly isolated by use of the appropriate safe isolation method. This Unit is for outdoor use only and must be mounted on suitable rigid & strong non-flammable surface. It is not designed to be used as a portable light. This product should be installed using suitably sized and strong fixings. The surface on which it is to be installed on should be strong enough to support the weight of the light. This product can be installed on surfaces with normal flammability (wood, plasterboard, masonry). It is not suitable to be installed on, or near highly flammable surfaces. Do not install on surfaces which are damp, or electrically conductive. The light should be positioned so that there is at least 500mm between the front of the fitting and any illuminated surface. This product is designed for permanent connection to a suitably protected fixed wiring installation. Do not carry or lift the floodlight by the mains supply cable. Only clean the light fitting with a soft dry cloth, do not use chemical or abrasive cleaning materials. The unit can get hot during use. Ensure the unit has cooled before handling. Ensure adequate ventilation space is allowed between the unit and any object above, in front or to either side of the unit. Suggested space is 0.5m above, 0.3m to either side & 1.0m in front. This unit should be installed by a qualified electrician.
Selecting The Location The motion sensor has a number of detection zones, at various vertical and horizontal angles. The maximum range is 12m. The detection angle is 120° When moving heat source crosses one of these zones it will activate the sensor. Careful positioning of the sensor will be required to ensure optimum performance. The sensor is more sensitive to movement ACROSS its field of vision than to movement directly TOWARDS. Therefore position the unit so that the sensor looks ACROSS the likely approach path. Avoid positioning the sensor where there are any sources of heat in the detection area(extractor fans, tumble dryer exhausts etc.). Reflective surfaces (ie pools of water or white-painted walls) and overhanging branches may cause false activation under extreme conditions.
INSTRUCTION MANUAL - Issue 1 - 02/2014
| 2
CHANNEL SAFETY SYSTEMS
t: 0845 884 7000 | w: www.channelsafety.co.uk
INSTALLATION 1.
Remove the wiring box cover.
2.
The unit is suitable for connection to a 230 V ac 50Hz supply. A 3-core round flexible cable of 1.0²mm/1.5²mm gauge is used. A means to isolate the unit should be installed to switch the power to the unit ON & OFF. This allows the sensor to be easily switched off when not required or for maintenance purposes.
3.
Remove the fixing bracket from the unit and mark the position of the fitting holes using the wall bracket as a template.
4.
Drill the holes. Insert the rawl plugs into the holes. Fix the bracket to the wall.
5.
Ensure the electrical supply is SWITCHED OFF
6. • • •
Connect the cable (SUPPLIED) to the electrical supply. Ensure a suitable junction box is used. NEUTRAL (Blue) N EARTH (Green/Yellow) LIVE (Brown) L
7.
Ensure that the connections are secure.
8.
Fix the floodlight to the bracket.
PIR SENSOR ADJUSTMENT To ensure adequate coverage the unit can be set up to allow a walk test to be carried out in normal day light.
Light sensitivity adjustment
INSTRUCTION MANUAL - Issue 1 - 02/2014
Operation duration adjustment
| 3
CHANNEL SAFETY SYSTEMS
t: 0845 884 7000 | w: www.channelsafety.co.uk
TESTING Walk Test Procedure The sensor will rotate from left to right, and tilt forward or backward. Adjust the sensor to point in the required direction. The unit can be set up in daylight or at night. Set the time adjustment to minimum (fully clockwise). Set the daylight sensor to maximum (fully anti clockwise) Turn the power to the unit on. The lamp will illuminate after approximately 30 seconds. This indicates the unit is correctly installed. After approximately 5-10 seconds the light will turn off. The unit is now in Test Mode. Light sensitivity adjustment Operation duration adjustment
Test Mode The lamp will now illuminate for approximately 5 seconds every time movement is detected. Walk around the area you require the unit to cover, each time the unit is triggered the light will illuminate for the set time. Stand still, or leave the field of coverage and the light will extinguish. If the detection area does not meet your requirements, adjust the sensor head accordingly.
Automatic Operation The unit timer is reset each time it senses movement. Therefore it will only extinguish after the set time once no movement has been detected. Adjust the time and day light sensor controls to meet your requirement. On time - Min: 5 second - Max: 6 minutes Light - Min: 3 lux – Max: 2000 Lux To set the light level set the control to the mid position, this equate to a ‘dusk’ level. Check the unit each evening. If the unit is starting to operate too early (i.e. when it is quite light) adjust the control slightly clockwise. If the unit starts to operate too late (i.e. when it is very dark). Adjust the control slightly anti -clockwise. Continue to adjust until the unit operates as desired.
INSTRUCTION MANUAL - Issue 1 - 02/2014
| 4
CHANNEL SAFETY SYSTEMS
t: 0845 884 7000 | w: www.channelsafety.co.uk
LAMP REPLACEMENT This luminaire uses a sealed LED lamp and is maintenance free. No lamp replacement is required.
Disposal At the end of the working life of the light or if you wish to upgrade or replace the unit it is essential that the correct disposal method is used. Please check with your supplier or local authority for the options available. Channel Safety Systems Limited are registered under the ‘WEEE Directive’ (Waste from Electrical and Electronic Equipment), our registration number is WEE/ JK0060TU
Assistance If you require assistance or the light becomes defective, please return it to where you purchased it. Alternatively you can call our helpline for advice. Please note the Helpline can only give product advice, not site specific advice.
INSTRUCTION MANUAL - Issue 1 - 02/2014
| 5
CHANNEL SAFETY SYSTEMS
t: 0845 884 7000 | w: www.channelsafety.co.uk
PASSIVE INFRARED MOTION DETECTOR The MP/PIR/BK PIR detector is used to automatically control lighting equipment. It detects heat movement within a given ‘field of view’. It has a wide field of view which can be adjusted in both the vertical and the horizontal planes. The detector incorporates an built in adjustable daylight sensor and adjustable timer. SPECIFICATION Power Source
220-240V/AC
Detection Range
140o
Power Frequency
50Hz
Working Temperature Ambient Light Working Humidity Time Delay
Installation Height Power Consumption Rated Load
Detection of movement Detection range IP Rating
-20 ~ +40oC 3-2000 Lux (Adjustable) <93%RH Min: 10 sec ± 3 sec Max: 7 min ± 2 min 1.8m~2.5m 0.45W 1200W (incandescent lamp) 300W (energy-saving lamp) 0.6~1.5m/s 12m max (<24oC) IP44
INSTRUCTION MANUAL - Issue 1 - 02/2014
| 6
CHANNEL SAFETY SYSTEMS
t: 0845 884 7000 | w: www.channelsafety.co.uk
OPERATION The MP/PIR/BK PIR detector can be adjusted to operate at variable light levels, from full daylight to less than 3 LUX. The MP/PIR/BK PIR detector has a variable timer which is adjustable from10 second to 7 minutes. Each time the detector is triggered the timer resets and starts the time period again. This ensures that the light is on no matter how long a moving person or vehicle is in the field of view.
Best sensitivity is across the field of view, objects which move towards the detector will be detected less quickly.
INSTRUCTION MANUAL - Issue 1 - 02/2014
| 7
CHANNEL SAFETY SYSTEMS
t: 0845 884 7000 | w: www.channelsafety.co.uk
PASSIVE INFRARED MOTION DETECTOR INSTALLATION Installation should be carried out by a qualified electrician. • • • • • •
Ensure the power is off and correctly isolated. Remove the screw from the bottom of the unit (a) Choose the cable entry points, rear or bottom entry. Fix the base to a suitable surface at the required location. Connect the power & load. Fix PIR back on to the base
INSTRUCTION MANUAL - Issue 1 - 02/2014
| 8
CHANNEL SAFETY SYSTEMS
t: 0845 884 7000 | w: www.channelsafety.co.uk
ADJUSTMENT AND TESTING
•
Turn the timer switch clockwise to the minimum setting (about 10 seconds).
•
Turn the lux level switch clockwise to the maximum light level (sun symbol).
•
Apply power. The unit takes about 30 seconds to ‘warm up’. The LED indicator and the load light(s) will operate.
•
After this period the LED indicator & load light(s) will extinguish
•
If there is no movement in the field of view the light will not illuminate until the PIR is triggered.
•
To test the ‘field of view’ area, walk out of range and then walk across the ‘field of view’. Once the unit is triggered the light will illuminate for approximately 10 seconds (once movement has stopped). Adjust the detection head as required for best coverage.
•
Once the unit is adjusted for coverage adjust the time setting by turning the time switch anti-clockwise. To accurately adjust the timer, simply trigger the unit and time the ‘light on’ time. Adjust according to your requirements.
•
To adjust the lux (light level) at which the unit will operate, turn the lux switch anti-clockwise to the mid point. Wait until the required level of darkness and attempt to trigger the unit. If it fails to operate, adjust accordingly. The minimum setting is 3 lux which is almost total darkness. Be aware of other light sources such as street lighting which may affect the ambient lighting levels.
Please note: • Avoid installing the PIR detector near sources of heat or cold air such as air conditioning units, boilers, flues etc. • Ensure clear ‘field of view’. • Ensure the PIR coverage is not affected by moving objects such as parked vehicles, doors, shutters, trees etc.
INSTRUCTION MANUAL - Issue 1 - 02/2014
| 9
CHANNEL SAFETY SYSTEMS Petersfield Business Park Bedford Road Petersfield Hampshire GU32 3QA
t: 0845 884 7000 f: 0845 884 6000
e:
[email protected] w: www.channelsafety.co.uk
INSTRUCTION MANUAL