Transcript
PRODUCT INTRODUCTION
MP1590B Network Performance Tester
ANRITSU CORPORATION
CONFIDENTIAL
Copyright 2004 by ANRITSU CORPORATION The contents of this manual shall not be disclosed in any way or reproduced in any media without the express written permission of Anritsu Corporation.
1
MBP-1SG040119-01
MP1590B Network Performance Tester Product Introduction
Anritsu 2nd Edition
1 / 30
What’s MP1590B? MP1590A - New! New!-- MU150101A 2.5G/2.6G 2.5G/2.6G EoS EoS Unit Unit MD1230A MU120101A/112A 10/100M Ethernet module module MD1230A MU120102A/112A Gigabit Ethernet module
• OTN, SONET/SDH • Jitter • PDH, DSn
MD1230A MU120118A 10Gigabit Ethernet module
EoS Virtual Concatenation
LCAS Next Generation Network
MP1590B 2 / 30
1
Features • Support Next-Generation Network measurement • Support both OTN/SDH/SONET measurement and Ethernet / IP measurement simultaneously • Support Ethernet modules of MD1230A • Support Jitter measurement • Support All units and functions of MP1590A
3 / 30
Next Generation Unit MU150101A
• • • • • • •
Bit rate: PDH, DSn, SONET/SDH (STM-0 to 16, OC1 to 48), OTU1 EoS measurement (F-GFP, LEX, LAPS(X.86))-155M/622M/2.5G Encapsulation (PPP, CiscoHDLC, MAPOS, Bulk) Virtual Concatenation LCAS measurement 256MB EoS/Ethernet frame capture Jitter measurement
4 / 30
2
EoS Measurement Example
GbE 1 GbE
GFP
2.5G SONET/SDH
NextGeneration
ADM
MP1590B
5 / 30
EoS - application Encapsulation Test EoS OC3/12/48, OC3/12/48, STM-1/4/16 STM-1/4/16 VT1.5/2, VCVT1.5/2, STS1/3, STS1/3, VC11/12/3/4 GFP-F, LAPS, GFP-F, LAPS, LEX 11/12/3/4
Ethernet frame
MP1590B
Ethernet frame
• Check encapsulation functions • Check throughput via Ethernet to EoS to Ethernet • Check error/alarm both Ethernet and SONET/SDH simultaneously
6 / 30
3
EoS- application Packet BER Test
F-GFP OC-48c/STM-16c OC-48c/STM-16c GbE GbE ** 22
Add/Drop MUX
Tx in SONET/SDH side 1
PRBS
2
PRBS
3
PRBS
4
PRBS
OH Payload
Rx in Ethernet side 3
PRBS
2
PRBS
1
PRBS
• Check PRBS errors • Check sequence numbers • Check frame loss
7 / 30
EoS - Frame Setting F-GFP Header Structure Setting Payload FCS switch Excluding ‘100’ Client Type
NULL, Linear Ring, ,,, Extension header is programmable
Ethernet Header Structure Setting
8 / 30
4
EoS - Real Time Counters / GFP Counters Transmitted GFP Frame Transmitted GFP Byte Received GFP Frame Received GFP Byte GFP FCS Error GFP uncorrectable cHEC GFP correctable cHEC GFP uncorrectable tHEC GFP correctable tHEC GFP eHEC Error Client Loss of Signal Frame Client Loss of Signal Interval
Client Loss of Sync Frame Client Loss of Sync Interval Server Signal Fail Interval
ØOver 40 SONET/SDH Counters ØOver 60 IP/Ethernet Counters
9 / 30
EoS - Capture and Decode EoS frame Capture and decode
GFP Header Information
Ethernet Header Information
10 / 30
5
Virtual concatenation - Mapping Structure Mapping structure for virtual concatenation Support both High order(VC3/4, STS1/3) and Low order(VC11/12,VT1.5/2) STM-16 STM -16
AUG AUG
STM-4 STM -4
AU4 AU4
VC4-Xv VC4-Xv
C4 C4
AU3 AU3
VC3-Xv VC3-Xv
C3 C3
VC12-Xv VC12-X v
C12 C12
VC11-Xv VC11-X v
C11 C11
STM-1 STM -1
SHD mode STS-48 STS-48 STS-12 STS-12 STS-3 STS-3
STS-3 STS-3
STS3c STS3c SPE SPE
STS3cSPE-Xv STS3cSPE-Xv
STS3cSPE STS3cSPE
STS1c STS1c SPE SPE
STS1cSPE-Xv STS1cSPE-Xv
STS1cSPE STS1cSPE
VT2SPE-Xv VT2SPE-Xv
VT2SPE VT2SPE
VT1.5-Xv VT1.5-Xv
VT1.5SPE VT1.5SPE
SONET mode
11 / 30
Virtual concatenation - VCAT member configuration Member setting for virtual concatenation group The member configuration of the transmitter side and receiver side can be set individually. It is possible to set channel position and SQ of VCAT members. Path
Size
STS-3c / VC
1 to 16
STS-1 / VC3(AU) 1 to 48 VT2 / VC12
1 to 63
VT1.5 / VC11
1 to 64
12 / 30
6
Virtual concatenation - Error Analysis Detect errors of all virtual concatenation groups MP1590B can analyze and display errors and VC group members. Complete data summary and VC group analysis is provided on one screen.
13 / 30
LCAS Function LCAS Function Ø Negotiation ON/OFF Ø LCAS Error/Alarm Addition VCAT-LOM,1stMFI,2ndMFI,MFI,SQM,GID,CRC8,CRC3
Ø LCAS Error/Alarm Counter VCAT-LOM,1stMFI,2ndMFI,MFI,SQM,GID,CRC8,CRC3
Ø LCAS Generator Ø LCAS Monitor Ø LCAS Capture Ø It is able to set the value for MST and RS-Ack These are transmitted according to both the received information and the setting condition when Negotiation is ON. These are transmitted according to the setting conditions when Negotiation is OFF.
14 / 30
7
LCAS - generator LCAS generator It is able to generate up to 64 LCAS scheme. The scheme test can be performed easily by graphically screen.
15 / 30
LCAS - monitor LCAS monitor Using the LCAS Monitoring, the translated status of all of the VCG members and all of the MST can be shown on a screen simultaneously.
16 / 30
8
LCAS - capture LCAS capture Capture up to 64 sequence of LCAS scheme. It is able to analyze the time scale of the scheme easily by simply reviewing the display time of the each sequence.
17 / 30
Ethernet module Ethernet Module Support Ethernet modules of MD1230A. It is possible to use OTN/SONET/SDH module and Ethernet modules simultaneously or independently. Standard Module
Advanced Protocol Module
MU120101A 10M/100M Ethernet Module
MU120111A 10/100M Ethernet Module
MU120102A Gigabit Ethernet Module
MU120112A Gigabit Ethernet Module
MU120118A 10Gigabit Ethernet Module
18 / 30
9
Performance Test Performance Test Support Ethernet and POS performance test DUT
•• •• •• •• •• •• ••
Throughput Throughput Latency Latency Variable Variable Packet Packet Counters Counters VLAN VLAN MPLS MPLS IPv6 IPv6 Short Short and and Jumbo Jumbo Frames Frames
MP1590B 10M/100M, Gigabit , 10Gigabit Ethernet STM1 to 16, OC3 to OC48 POS
19 / 30
Automatic Test Automatic Test Ethernet I/F Module support Automatic test according to RFC2544. After click “start button”, it measures automatically and show the result as a graph Ø Throughput Ø Latency Ø Frame Loss Rate
One click operation
Ø Back to Back Frames Ø System Recovery Ø Reset
EoS Unit doesn’t support this function. 20 / 30
10
QoS Test QoS Test Ethernet modules have 8 QoS counters. It is possible to check the performance of priority control. Network
Frames with various priorities QoS screen monitors 8 priority levels simultaneously
21 / 30
Ethernet BER Test Packet BER Test (Option-11) Check BER and sequence for data field of each packet • Packet BER • Sequence check • Packet Loss
Test pattern and sequence number in data field of frames
Unframed BER Test Check BER for all area of packet • • • • • •
All0, All1 User 16bits PRBS23 PRBS31 CRPAT CJPAT
Unframe Pattern Data
WDM line
With IFG 01101001010 01101001010 01101001010 01101001010
22 / 30
11
Software options Software options Support the following software options that are the same as MD1230. X = available
Option
10M/100M
Name
MU120 101A
Option-07
OSPF Protocol
Option-08 Option-09
MPLS(LDP/CR-LDP) Protocol MPLS(RSVP) Protocol
Option-10
RFC2889 Benchmarking Test
Option-11
Packet BER Test
Option-12
IPv6 Expansion
Option-13
XENPAK Test
Option-14
IGAP Protocol
Option-16
Link Fault Signaling
GbE
MU120 111A
MU120 102A
MU120 112A
X X
X X
X X X X
X X X X
X X
X
10GbE
EoS
MU120 118A
MU150 101A
X
X X X X X
23 / 30
Unit configuration Interface slots Slot1
or
Slot2
MU150100A (1.5M to 10.7G)
MU150101A (1.5M to 2.6G)
Slot3
Optical Tx Unit
or
Ethernet Module
Slot4
Optical Rx Unit
or
Ethernet Module
Slot5
Jitter Unit
or
Ethernet Module
Slot6
Jitter Unit
or
Ethernet Module
24 / 30
12
Unit configuration Configuration Example MP1590B
10/10.7G with Jitter Slot1 Slot2
Slot2 Slot3 Slot4 Slot5 Slot6
Ethernet modules can be installed on slot 3,4,5 and 6
Slot2
MU150100A
Optical Tx Unit
Slot3
Optical Tx Unit
Slot4
Optical Rx Unit
Slot4
Optical Rx Unit
Slot6
Slot1
Slot1
Slot3 Slot5
Ethernet Only
MU150100A
10/10.7G
Jitter Unit
Slot5 Slot6
Don’t insert Ethernet module Ethernet modules can be installed on slot 5 and 6 2.5/2.6G with Jitter 2.5/2.6G Slot1 Slot2
MU150101A
Slot1 Slot2
Slot3
Slot3
Slot4
Slot4
Slot5 Slot6
Jitter Unit
Ethernet modules can be installed on slot 3 and 4
MU150101A
Slot5 Slot6
Ethernet modules can be installed on slot 3,4,5 and 6
25 / 30
OTN / SONET/SDH OTN, SONET/SDH MP1590B support all functions and modules of MP1590A Ø Ø Ø Ø Ø Ø Ø
ITU-T G.709 OTN measurement OTN, SONET/SDH overhead setting and monitoring Arbitrary concatenation Error analysis (error performance) Through mode Clock/frame synchronization signal output External optical input function
26 / 30
13
Jitter Jitter MP1590B support all function of MP1590A Ø Ø Ø
Jitter Tolerance Jitter Transfer Jitter Generation
27 / 30
Other functions Operation mode MP1590B has 2 operation mode to operate easily and efficiently for Ethernet and OTN/SONET/SDH. OTN/SONET/SDH mode
EOS mode
28 / 30
14
Model Name - Option Model
Option
Name
Model
Option
Name
MP1590B
-01
RS232C
MU150101A
-01
Wavelength 1.31um
-02
GPIB
-02
Wavelength 1.55um
-03
LAN
-03
Wavelength 1.31/1.55um
-07
OSPF Protocol
-04
Optical output power adjustable
-08
MPLS(LDP/CR-LDP) Protocol
-05
OTU1
-09
MPLS(RSVP) Protocol
-06
GFP-F/LEX/LAPS
-10
RFC2889 Benchmarking Test
-07
POS
-11
Packet BER Test
-11
HO Virtual Concatenation
-12
IPv6 Expansion
-12
LO Virtual Concatenation
-13
XENPAK Test
-13
LCAS
-14
IGAP Protocol
-38
ST Connecter
-16
Link Fault Signaling
-39
DIN Connecter
MU150100A
-30
High-accuracy Jitter measurement
-40
SC Connecter
-90
Three year warranty
-90
Three year warranty
-09
Insert/Extract
29 / 30
Thank you very much!!
30 / 30
15
MP1590B PRODUCT INTRODUCTION
Confidential
Specifications are subject to change without notice.
ANRITSU CORPORATION 1800 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan Phone: +81-46-223-1111 Fax: +81-46-296-1264
• U.S.A.
ANRITSU COMPANY TX OFFICE SALES AND SERVICE
1155 East Collins Blvd., Richardson, TX 75081, U.S.A. Toll Free: 1-800-ANRITSU (267-4878) Phone: +1- 972-644-1777 Fax: +1-972-644-3416
• Canada
ANRITSU ELECTRONICS LTD.
700 Silver Seven Road, Suite 120, Kanata, ON K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006
• Brasil
ANRITSU ELETRÔNICA LTDA.
Praca Amadeu Amaral, 27 - 1 andar 01327-010 - Paraiso, Sao Paulo, Brazil Phone: +55-11-3283-2511 Fax: +55-11-3886940
• U.K.
ANRITSU LTD.
200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K. Phone: +44-1582-433280 Fax: +44-1582-731303
Printed on 100% Recycled Paper
• Germany
• Hong Kong ANRITSU COMPANY LTD.
Grafenberger Allee 54-56, 40237 Düsseldorf, Germany Phone: +49-211-96855-0 Fax: +49-211-96855-55
Suite 923, 9/F., Chinachem Golden Plaza, 77 Mody Road, Tsimshatsui East, Kowloon, Hong Kong, China Phone: +852-2301-4980 Fax: +852-2301-3545
ANRITSU GmbH
• France
ANRITSU S.A.
9, Avenue du Québec Z.A. de Courtabœuf 91951 Les Ulis Cedex, France Phone: +33-1-60-92-15-50 Fax: +33-1-64-46-10-65
• Italy ANRITSU S.p.A.
Via Elio Vittorini, 129, 00144 Roma EUR, Italy Phone: +39-06-509-9711 Fax: +39-06-502-2425
• Sweden
ANRITSU AB
• P. R. China ANRITSU COMPANY LTD. Beijing Representative Office
Room 1515, Beijing Fortune Building, No. 5 North Road, the East 3rd Ring Road, Chao-Yang District Beijing 100004, P.R. China Phone: +86-10-6590-9230
• Korea ANRITSU CORPORATION
8F Hyun Juk Bldg. 832-41, Yeoksam-dong, Kangnam-ku, Seoul, 135-080, Korea Phone: +82-2-553-6603 Fax: +82-2-553-6604
Borgafjordsgatan 13 164 40 Kista, Sweden Phone: +46-853470700 Fax: +46-853470730
• Australia ANRITSU PTY LTD.
ANRITSU PTE LTD.
Unit 3/170 Forster Road Mt. Waverley, Victoria, 3149, Australia Phone: +61-3-9558-8177 Fax: +61-3-9558-8255
• Singapore
10, Hoe Chiang Road #07-01/02, Keppel Towers, Singapore 089315 Phone: +65-6282-2400 Fax: +65-6282-2533
• Taiwan ANRITSU COMPANY INC.
7F, No. 316, Sec. 1, NeiHu Rd., Taipei, Taiwan Phone: +886-2-8751-1816 Fax: +886-2-8751-1817
No.MP1590B-E-I-1-(2.00)
040602
Printed in Japan 2004-9 AKD