Preview only show first 10 pages with watermark. For full document please download

Mp1590b - Cloudfront.net

   EMBED


Share

Transcript

PRODUCT INTRODUCTION MP1590B Network Performance Tester ANRITSU CORPORATION CONFIDENTIAL Copyright  2004 by ANRITSU CORPORATION The contents of this manual shall not be disclosed in any way or reproduced in any media without the express written permission of Anritsu Corporation. 1 MBP-1SG040119-01 MP1590B Network Performance Tester Product Introduction Anritsu 2nd Edition 1 / 30 What’s MP1590B? MP1590A - New! New!-- MU150101A 2.5G/2.6G 2.5G/2.6G EoS EoS Unit Unit MD1230A MU120101A/112A 10/100M Ethernet module module MD1230A MU120102A/112A Gigabit Ethernet module • OTN, SONET/SDH • Jitter • PDH, DSn MD1230A MU120118A 10Gigabit Ethernet module EoS Virtual Concatenation LCAS Next Generation Network MP1590B 2 / 30 1 Features • Support Next-Generation Network measurement • Support both OTN/SDH/SONET measurement and Ethernet / IP measurement simultaneously • Support Ethernet modules of MD1230A • Support Jitter measurement • Support All units and functions of MP1590A 3 / 30 Next Generation Unit MU150101A • • • • • • • Bit rate: PDH, DSn, SONET/SDH (STM-0 to 16, OC1 to 48), OTU1 EoS measurement (F-GFP, LEX, LAPS(X.86))-155M/622M/2.5G Encapsulation (PPP, CiscoHDLC, MAPOS, Bulk) Virtual Concatenation LCAS measurement 256MB EoS/Ethernet frame capture Jitter measurement 4 / 30 2 EoS Measurement Example GbE 1 GbE GFP 2.5G SONET/SDH NextGeneration ADM MP1590B 5 / 30 EoS - application Encapsulation Test EoS OC3/12/48, OC3/12/48, STM-1/4/16 STM-1/4/16 VT1.5/2, VCVT1.5/2, STS1/3, STS1/3, VC11/12/3/4 GFP-F, LAPS, GFP-F, LAPS, LEX 11/12/3/4 Ethernet frame MP1590B Ethernet frame • Check encapsulation functions • Check throughput via Ethernet to EoS to Ethernet • Check error/alarm both Ethernet and SONET/SDH simultaneously 6 / 30 3 EoS- application Packet BER Test F-GFP OC-48c/STM-16c OC-48c/STM-16c GbE GbE ** 22 Add/Drop MUX Tx in SONET/SDH side 1 PRBS 2 PRBS 3 PRBS 4 PRBS OH Payload Rx in Ethernet side 3 PRBS 2 PRBS 1 PRBS • Check PRBS errors • Check sequence numbers • Check frame loss 7 / 30 EoS - Frame Setting F-GFP Header Structure Setting Payload FCS switch Excluding ‘100’ Client Type NULL, Linear Ring, ,,, Extension header is programmable Ethernet Header Structure Setting 8 / 30 4 EoS - Real Time Counters / GFP Counters Transmitted GFP Frame Transmitted GFP Byte Received GFP Frame Received GFP Byte GFP FCS Error GFP uncorrectable cHEC GFP correctable cHEC GFP uncorrectable tHEC GFP correctable tHEC GFP eHEC Error Client Loss of Signal Frame Client Loss of Signal Interval Client Loss of Sync Frame Client Loss of Sync Interval Server Signal Fail Interval ØOver 40 SONET/SDH Counters ØOver 60 IP/Ethernet Counters 9 / 30 EoS - Capture and Decode EoS frame Capture and decode GFP Header Information Ethernet Header Information 10 / 30 5 Virtual concatenation - Mapping Structure Mapping structure for virtual concatenation Support both High order(VC3/4, STS1/3) and Low order(VC11/12,VT1.5/2) STM-16 STM -16 AUG AUG STM-4 STM -4 AU4 AU4 VC4-Xv VC4-Xv C4 C4 AU3 AU3 VC3-Xv VC3-Xv C3 C3 VC12-Xv VC12-X v C12 C12 VC11-Xv VC11-X v C11 C11 STM-1 STM -1 SHD mode STS-48 STS-48 STS-12 STS-12 STS-3 STS-3 STS-3 STS-3 STS3c STS3c SPE SPE STS3cSPE-Xv STS3cSPE-Xv STS3cSPE STS3cSPE STS1c STS1c SPE SPE STS1cSPE-Xv STS1cSPE-Xv STS1cSPE STS1cSPE VT2SPE-Xv VT2SPE-Xv VT2SPE VT2SPE VT1.5-Xv VT1.5-Xv VT1.5SPE VT1.5SPE SONET mode 11 / 30 Virtual concatenation - VCAT member configuration Member setting for virtual concatenation group The member configuration of the transmitter side and receiver side can be set individually. It is possible to set channel position and SQ of VCAT members. Path Size STS-3c / VC 1 to 16 STS-1 / VC3(AU) 1 to 48 VT2 / VC12 1 to 63 VT1.5 / VC11 1 to 64 12 / 30 6 Virtual concatenation - Error Analysis Detect errors of all virtual concatenation groups MP1590B can analyze and display errors and VC group members. Complete data summary and VC group analysis is provided on one screen. 13 / 30 LCAS Function LCAS Function Ø Negotiation ON/OFF Ø LCAS Error/Alarm Addition VCAT-LOM,1stMFI,2ndMFI,MFI,SQM,GID,CRC8,CRC3 Ø LCAS Error/Alarm Counter VCAT-LOM,1stMFI,2ndMFI,MFI,SQM,GID,CRC8,CRC3 Ø LCAS Generator Ø LCAS Monitor Ø LCAS Capture Ø It is able to set the value for MST and RS-Ack These are transmitted according to both the received information and the setting condition when Negotiation is ON. These are transmitted according to the setting conditions when Negotiation is OFF. 14 / 30 7 LCAS - generator LCAS generator It is able to generate up to 64 LCAS scheme. The scheme test can be performed easily by graphically screen. 15 / 30 LCAS - monitor LCAS monitor Using the LCAS Monitoring, the translated status of all of the VCG members and all of the MST can be shown on a screen simultaneously. 16 / 30 8 LCAS - capture LCAS capture Capture up to 64 sequence of LCAS scheme. It is able to analyze the time scale of the scheme easily by simply reviewing the display time of the each sequence. 17 / 30 Ethernet module Ethernet Module Support Ethernet modules of MD1230A. It is possible to use OTN/SONET/SDH module and Ethernet modules simultaneously or independently. Standard Module Advanced Protocol Module MU120101A 10M/100M Ethernet Module MU120111A 10/100M Ethernet Module MU120102A Gigabit Ethernet Module MU120112A Gigabit Ethernet Module MU120118A 10Gigabit Ethernet Module 18 / 30 9 Performance Test Performance Test Support Ethernet and POS performance test DUT •• •• •• •• •• •• •• Throughput Throughput Latency Latency Variable Variable Packet Packet Counters Counters VLAN VLAN MPLS MPLS IPv6 IPv6 Short Short and and Jumbo Jumbo Frames Frames MP1590B 10M/100M, Gigabit , 10Gigabit Ethernet STM1 to 16, OC3 to OC48 POS 19 / 30 Automatic Test Automatic Test Ethernet I/F Module support Automatic test according to RFC2544. After click “start button”, it measures automatically and show the result as a graph Ø Throughput Ø Latency Ø Frame Loss Rate One click operation Ø Back to Back Frames Ø System Recovery Ø Reset EoS Unit doesn’t support this function. 20 / 30 10 QoS Test QoS Test Ethernet modules have 8 QoS counters. It is possible to check the performance of priority control. Network Frames with various priorities QoS screen monitors 8 priority levels simultaneously 21 / 30 Ethernet BER Test Packet BER Test (Option-11) Check BER and sequence for data field of each packet • Packet BER • Sequence check • Packet Loss Test pattern and sequence number in data field of frames Unframed BER Test Check BER for all area of packet • • • • • • All0, All1 User 16bits PRBS23 PRBS31 CRPAT CJPAT Unframe Pattern Data WDM line With IFG 01101001010 01101001010 01101001010 01101001010 22 / 30 11 Software options Software options Support the following software options that are the same as MD1230. X = available Option 10M/100M Name MU120 101A Option-07 OSPF Protocol Option-08 Option-09 MPLS(LDP/CR-LDP) Protocol MPLS(RSVP) Protocol Option-10 RFC2889 Benchmarking Test Option-11 Packet BER Test Option-12 IPv6 Expansion Option-13 XENPAK Test Option-14 IGAP Protocol Option-16 Link Fault Signaling GbE MU120 111A MU120 102A MU120 112A X X X X X X X X X X X X X X X 10GbE EoS MU120 118A MU150 101A X X X X X X 23 / 30 Unit configuration Interface slots Slot1 or Slot2 MU150100A (1.5M to 10.7G) MU150101A (1.5M to 2.6G) Slot3 Optical Tx Unit or Ethernet Module Slot4 Optical Rx Unit or Ethernet Module Slot5 Jitter Unit or Ethernet Module Slot6 Jitter Unit or Ethernet Module 24 / 30 12 Unit configuration Configuration Example MP1590B 10/10.7G with Jitter Slot1 Slot2 Slot2 Slot3 Slot4 Slot5 Slot6 Ethernet modules can be installed on slot 3,4,5 and 6 Slot2 MU150100A Optical Tx Unit Slot3 Optical Tx Unit Slot4 Optical Rx Unit Slot4 Optical Rx Unit Slot6 Slot1 Slot1 Slot3 Slot5 Ethernet Only MU150100A 10/10.7G Jitter Unit Slot5 Slot6 Don’t insert Ethernet module Ethernet modules can be installed on slot 5 and 6 2.5/2.6G with Jitter 2.5/2.6G Slot1 Slot2 MU150101A Slot1 Slot2 Slot3 Slot3 Slot4 Slot4 Slot5 Slot6 Jitter Unit Ethernet modules can be installed on slot 3 and 4 MU150101A Slot5 Slot6 Ethernet modules can be installed on slot 3,4,5 and 6 25 / 30 OTN / SONET/SDH OTN, SONET/SDH MP1590B support all functions and modules of MP1590A Ø Ø Ø Ø Ø Ø Ø ITU-T G.709 OTN measurement OTN, SONET/SDH overhead setting and monitoring Arbitrary concatenation Error analysis (error performance) Through mode Clock/frame synchronization signal output External optical input function 26 / 30 13 Jitter Jitter MP1590B support all function of MP1590A Ø Ø Ø Jitter Tolerance Jitter Transfer Jitter Generation 27 / 30 Other functions Operation mode MP1590B has 2 operation mode to operate easily and efficiently for Ethernet and OTN/SONET/SDH. OTN/SONET/SDH mode EOS mode 28 / 30 14 Model Name - Option Model Option Name Model Option Name MP1590B -01 RS232C MU150101A -01 Wavelength 1.31um -02 GPIB -02 Wavelength 1.55um -03 LAN -03 Wavelength 1.31/1.55um -07 OSPF Protocol -04 Optical output power adjustable -08 MPLS(LDP/CR-LDP) Protocol -05 OTU1 -09 MPLS(RSVP) Protocol -06 GFP-F/LEX/LAPS -10 RFC2889 Benchmarking Test -07 POS -11 Packet BER Test -11 HO Virtual Concatenation -12 IPv6 Expansion -12 LO Virtual Concatenation -13 XENPAK Test -13 LCAS -14 IGAP Protocol -38 ST Connecter -16 Link Fault Signaling -39 DIN Connecter MU150100A -30 High-accuracy Jitter measurement -40 SC Connecter -90 Three year warranty -90 Three year warranty -09 Insert/Extract 29 / 30 Thank you very much!! 30 / 30 15 MP1590B PRODUCT INTRODUCTION Confidential Specifications are subject to change without notice. ANRITSU CORPORATION 1800 Onna, Atsugi-shi, Kanagawa, 243-8555 Japan Phone: +81-46-223-1111 Fax: +81-46-296-1264 • U.S.A. ANRITSU COMPANY TX OFFICE SALES AND SERVICE 1155 East Collins Blvd., Richardson, TX 75081, U.S.A. Toll Free: 1-800-ANRITSU (267-4878) Phone: +1- 972-644-1777 Fax: +1-972-644-3416 • Canada ANRITSU ELECTRONICS LTD. 700 Silver Seven Road, Suite 120, Kanata, ON K2V 1C3, Canada Phone: +1-613-591-2003 Fax: +1-613-591-1006 • Brasil ANRITSU ELETRÔNICA LTDA. Praca Amadeu Amaral, 27 - 1 andar 01327-010 - Paraiso, Sao Paulo, Brazil Phone: +55-11-3283-2511 Fax: +55-11-3886940 • U.K. ANRITSU LTD. 200 Capability Green, Luton, Bedfordshire LU1 3LU, U.K. Phone: +44-1582-433280 Fax: +44-1582-731303 Printed on 100% Recycled Paper • Germany • Hong Kong ANRITSU COMPANY LTD. Grafenberger Allee 54-56, 40237 Düsseldorf, Germany Phone: +49-211-96855-0 Fax: +49-211-96855-55 Suite 923, 9/F., Chinachem Golden Plaza, 77 Mody Road, Tsimshatsui East, Kowloon, Hong Kong, China Phone: +852-2301-4980 Fax: +852-2301-3545 ANRITSU GmbH • France ANRITSU S.A. 9, Avenue du Québec Z.A. de Courtabœuf 91951 Les Ulis Cedex, France Phone: +33-1-60-92-15-50 Fax: +33-1-64-46-10-65 • Italy ANRITSU S.p.A. Via Elio Vittorini, 129, 00144 Roma EUR, Italy Phone: +39-06-509-9711 Fax: +39-06-502-2425 • Sweden ANRITSU AB • P. R. China ANRITSU COMPANY LTD. Beijing Representative Office Room 1515, Beijing Fortune Building, No. 5 North Road, the East 3rd Ring Road, Chao-Yang District Beijing 100004, P.R. China Phone: +86-10-6590-9230 • Korea ANRITSU CORPORATION 8F Hyun Juk Bldg. 832-41, Yeoksam-dong, Kangnam-ku, Seoul, 135-080, Korea Phone: +82-2-553-6603 Fax: +82-2-553-6604 Borgafjordsgatan 13 164 40 Kista, Sweden Phone: +46-853470700 Fax: +46-853470730 • Australia ANRITSU PTY LTD. ANRITSU PTE LTD. Unit 3/170 Forster Road Mt. Waverley, Victoria, 3149, Australia Phone: +61-3-9558-8177 Fax: +61-3-9558-8255 • Singapore 10, Hoe Chiang Road #07-01/02, Keppel Towers, Singapore 089315 Phone: +65-6282-2400 Fax: +65-6282-2533 • Taiwan ANRITSU COMPANY INC. 7F, No. 316, Sec. 1, NeiHu Rd., Taipei, Taiwan Phone: +886-2-8751-1816 Fax: +886-2-8751-1817 No.MP1590B-E-I-1-(2.00) 040602 Printed in Japan 2004-9 AKD