Preview only show first 10 pages with watermark. For full document please download

Ms-1221 Ver : 0.b - Kythuatphancung.com

   EMBED


Share

Transcript

5 4 MS-1221 VER : 0.B 3 2006/09/05 2 1 Merom 478 Page 3,4 D C B 01 : BLOCK DIAGRAM 02 : PLATFORM 03 : Merom-1 CPU (HOST BUS) 04 : Merom-2 CPU (POWER/GND) 05 : 965GM-1 (HOST) 06 : 965GM-2 (DMI / VGA) 07 : 965GM-3 (DDR) 08 : 965GM-4 (Power-1) 09 : 965GM-5 (Power-2) 10 : 965GM-6 (GND) 11 : DDR2_SODIMM0 12 : DDR2_SODIMM1 13 : DDR2_Termination 14 : SDVO- SiI1390 15 : CLOCK GEN (ICS9LP505-1) 16 : VGA, LVDS ,BL 17 : ICH8M-1 (CPU/IDE/Azalia) 18 : ICH8M-2 (PCI/USB/PCIE/DMI) 19 : ICH8M-3 (SM BUS/GPIO) 20 : ICH8M-4 (POWER/GND) 21 : ENE3910( KBC ) & BIOS 22 : HDD,CDROM,CIR,USB CONN. 23 : Card Reader (MR510) 24 : PCIE LAN (RTL 8111B) 25 : MINI_PCIE, LED, SW 26 : NEWCARD, MDC, TPM, FAN 27 : AZALIA CODEC(ALC883) 28 : Audio Amp. & Jacks 29 : M_Battery Select 30 : M_Battery Charger 31 : M_System Power 32 : DDR2 RAM POWER, +1.25V 33 : M_VTT, +1.5V 34 : M_CPU power 35 : M_Graphics Core 36 : Screw / EMI 37 : Non-Footprint for BOM 38 : KBC_CTR_PWR_BD 39 : Power Sequency 40 : Change History +3V +5V TPS51120 DC JACK & Selector Page 31 VTT(1.05V) +1_5VRUN Page 29 HOST LVDS Page 16 HDMI SiI1390 Page 14 +1_8VDIMM SMDDR_VTERM NORTH BRIDGE RGB SC486 Dual Channel DDRII 533/667 MHZ INTEL Crestline 965GM 1299 SDVO Page 14 D Page 33 SYS POWER Page 16 CRT Page 32 OZ813 FSB 667/800 LVDS +1_25VRUN APL5913 Dual Channel DDRII 533/667 MHZ Page 32 DDR-SODIMM0 Page 11 CPU POWER ISL6262A DDR-SODIMM1 Page 12 Page 34 Page 5 ~ 10 CHARGER MAX 1772 DMI Interface MINI PCIE Conn. x2 Page 25 EXPRESS CARD Page 26 C Page 30 PATA Graphics Core ISL6263 DVD/CDROM Page 22 Page 35 PCIE-LAN RTL8111B Page 24 SD/MMC/MS 3 IN 1 CARD MR510 Page 23 Internal SPK MIC Earphone SPDIF Out Internal MIC SATA SOUTH BRIDGE PCI-EXPRESS PCI BUS HDD Page 22 INTEL USB1.1/2.0 ICH8M 676 ALC883H Azalia Connectors Page 27 Page 17 ~ 20 MDC Mini_PCIE New_CARD Bluetooth Fingerprint B USB 0,2,6 USB 1 Page 22 Page 22 USB 3,5 Page 25 USB 9 USB 7 USB 4 Page 26 Page 22 Page 22 Page 26 LPC BUS Page 28 Camera LPC DUBUG TPM 1.2 Page 26 Page 21 KBC ENE 3910 Page 21 TP & KB Page 21 ISA BIOS Page 21 14MHZ CRYSTAL 133/166MHZ CLK GEN CK505 HOST A 100MHZ PC IE 14MHZ SB A ICS9LP505-1 Page 15 33MHZ PCI MSI CORPORATION Title BLOCK DIAGRAM Size C Date: 5 [email protected] GRATIS - FOR FREE 4 3 2 Document Number Rev 0B MS-1221 Wednesday, September 06, 2006 1 Sheet 1 of 41 5 4 3 2 1 Voltage Rails Voltage D Description Control Signal PWR_SRC AC ADAPTER OR BATTERY IN VHCORE Core Voltage for Processor VR_ON VTT 1.05 rail for Processor & 965GM I/O RUN_ON +1_5VRUN 1.5V switched power rail (off in S3-S5) RUN_ON +2_5VRUN 2.5V powe rail for CH7315A (off in S3-S5) +3VRUN +3VRUN 3.3V switched power rail (off in S3-S5) RUN_ON +5VRUN 5.0V switched power rail (off in S3-S5) RUN_ON 0.9V DDR Termination voltage (off in S4-S5) DIMM_ON 1.8V power rail DDR (off in S4-S5) DIMM_ON SMDDR_VTERM +1_8VDIMM D C C +3VSUS 3.3V power rail (off in S4-S5) SUS_ON +5VSUS 5.0V power rail (off in S4-S5) SUS_ON +3VALW 3.3V always on power rail PWR_SRC +5VALW 5.0V always on power rail PWR_SRC ADD5V 5.0V Power rail Audio codec(off in S3-S5) +5VRUN +1_25VRUN 1.25V LDO power rail (off in S3-S5) RUN_ON +VGFX_CORE Graphic core of GMCH switched power rail (off in S3-S5) GFX_VR_EN B B POWER STATES SIGNAL SLP_S3# SLP_S4# SLP_S5# +V*ALWAYS +V*SUS +V*RUN Clocks HIGH HIGH HIGH ON ON ON ON S1M(Power On Suspend) HIGH HIGH HIGH ON ON ON LOW STATE S0( Full ON) S3( Suspend to RAM) LOW HIGH HIGH ON ON OFF OFF S4( Suspend to Disk) LOW LOW HIGH ON OFF OFF OFF S5 / Soft OFF LOW LOW LOW ON OFF OFF OFF Note : WHEN AC MODE , System turn on then high +V*SUS will always keep A A MSI CORPORATION Title PLATFORM Size Document Number Custom Date: 5 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 2 of 41 A B 5 5 D E H_A#[35:3] H_A#[35:3] 5 C H_RS#[2:0] H_RS#[2:0] H_REQ#[4:0] H_REQ#[4:0] 1 1 VTT U26A H_ADSTB#1 H_A20M# H_FERR# H_IGNNE# A6 A5 C4 17 17 17 17 H_STPCLK# H_INTR H_NMI H_SMI# D5 C6 B4 A3 3 TP63 TP61 TP46 TP53 TP54 TP51 TP45 TP92 TP59 TP68 RSVD_01 RSVD_02 RSVD_03 RSVD_04 RSVD_05 RSVD_06 RSVD_07 RSVD_08 RSVD_09 RSVD_10 M4 N5 T2 V3 B2 C3 D2 D22 D3 F6 A20M# FERR# IGNNE# F1 D20 B3 H_DEFER# H_DRDY# H_DBSY# 5 5 5 H_BREQ# 5 R217 56R0402 5 HTMS R183 39R0402 HTDI R182 150R1%0402 PREQ# R181 56R0402 H_PROCHOT# R218 56R0402 HTCK R185 27R0402 HTRST# R190 680R0402 PROCHOT# THERMDA THERMDC THERMTRIP# H_RS#0 H_RS#1 H_RS#2 H_INIT# 17 H_LOCK# 5 H_CPURST# 5 H_TRDY# G6 E4 H_HIT# H_HITM# AD4 AD3 AD1 AC4 AC2 AC1 AC5 AA6 AB3 AB5 AB6 C20 5 5 5 5 5 5 5 H_D#0 H_D#1 H_D#2 H_D#3 H_D#4 H_D#5 H_D#6 H_D#7 H_D#8 H_D#9 H_D#10 H_D#11 H_D#12 H_D#13 H_D#14 H_D#15 H_D#16 H_D#17 H_D#18 H_D#19 H_D#20 H_D#21 H_D#22 H_D#23 H_D#24 H_D#25 H_D#26 H_D#27 H_D#28 H_D#29 H_D#30 H_D#31 R226 HTMS HTRST# 1KR1%0402 Within 0.5" R223 H_PROCHOT# THERMDA THERMDC D21 A24 B25 C7 5 5 5 2KR1%0402 BCLK[0] BCLK[1] GTLREF TEST1 TEST2 TEST3 TEST4 TEST5 TEST6 PM_THRMTRIP# 6,17 A22 A21 R220 CLK_CPU_BCLK 15 CLK_CPU_BCLK# 15 X_1KR0402 TP44 TP101 R221 C427 X_1KR0402 X_C0.1U10X0402 N22 K25 P26 R23 L23 M24 L22 M23 P25 P23 P22 T24 R24 L25 T25 N25 L26 M26 N24 H_DSTBN#1 H_DSTBP#1 H_DINV#1 TP98 H CLK E22 F24 E26 G22 F23 G25 E25 E23 K24 G24 J24 J23 H22 F26 K22 H23 J26 H26 H25 H_DSTBN#0 H_DSTBP#0 H_DINV#0 H_D#[63:0] VTT PREQ# HTCK HTDI 15 15 CPU_BSEL0 CPU_BSEL1 AD26 C23 D25 C24 AF26 AF1 A26 B22 B23 C21 CPU_BSEL2 TP89 D[0]# D[1]# D[2]# D[3]# D[4]# D[5]# D[6]# D[7]# D[8]# D[9]# D[10]# D[11]# D[12]# D[13]# D[14]# D[15]# DSTBN[0]# DSTBP[0]# DINV[0]# D[16]# D[17]# D[18]# D[19]# D[20]# D[21]# D[22]# D[23]# D[24]# D[25]# D[26]# D[27]# D[28]# D[29]# D[30]# D[31]# DSTBN[1]# DSTBP[1]# DINV[1]# GTLREF TEST1 TEST2 TEST3 TEST4 TEST5 TEST6 MISC D[32]# D[33]# D[34]# D[35]# D[36]# D[37]# D[38]# D[39]# D[40]# D[41]# D[42]# D[43]# D[44]# D[45]# D[46]# D[47]# DSTBN[2]# DSTBP[2]# DINV[2]# D[48]# D[49]# D[50]# D[51]# D[52]# D[53]# D[54]# D[55]# D[56]# D[57]# D[58]# D[59]# D[60]# D[61]# D[62]# D[63]# DSTBN[3]# DSTBP[3]# DINV[3]# COMP[0] COMP[1] COMP[2] COMP[3] DPRSTP# DPSLP# DPWR# PWRGOOD SLP# PSI# BSEL[0] BSEL[1] BSEL[2] AE24 AD24 AA21 AB22 AB21 AC26 AD20 AE22 AF23 AC25 AE21 AD21 AC22 AD23 AF22 AC23 AE25 AF24 AC20 H_D#48 H_D#49 H_D#50 H_D#51 H_D#52 H_D#53 H_D#54 H_D#55 H_D#56 H_D#57 H_D#58 H_D#59 H_D#60 H_D#61 H_D#62 H_D#63 R26 U26 AA1 Y1 COMP0 COMP1 COMP2 COMP3 H_D#[63:0] 5 H_DSTBN#2 5 H_DSTBP#2 5 H_DINV#2 5 2 H_D#[63:0] 5 H_DSTBN#3 5 H_DSTBP#3 5 H_DINV#3 5 E5 B5 D24 D6 D7 AE6 R225 R224 R186 R188 27.4R1% 54.9R1%0402 27.4R1% 54.9R1%0402 3 H_DPRSTP# 6,17,34 H_DPSLP# 17 H_DPWR# 5 H_PWRGD 17 H_CPUSLP# 5 PSI# 34 Cap close to thermal sensor +3VRUN +3VRUN +3VALW U28 1 R384 10KR0402 R385 D RSMRST# X_0R0402 Trace : 10/4/10 C434 2 C2200P50X0402 G 4 S THERMDC 3 4 VDD D+ DT_CRIT_A# SMBCLK SMBDATA ALERT# GND 8 SMB_CPU_CLK 7 SMB_CPU_DATA 6 THERMAL_INT# SMB_CPU_CLK SMB_CPU_DATA THERMAL_INT# Q28 21 21 21 SMB_CPU_CLK R379 2.2KR0402 SMB_CPU_DATA R381 2.2KR0402 THERMAL_INT# R24 MSI CORPORATION Title Merom-1 (HOST BUS) Close to CPU socket Size Document Number Custom Date: B C 4 10KR0402 5 C430 LM86CIMMXNOPB_MSOP8-RH C0.1U10X0402 N-2N7002_SOT23 [email protected] GRATIS - FOR FREE H_D#32 H_D#33 H_D#34 H_D#35 H_D#36 H_D#37 H_D#38 H_D#39 H_D#40 H_D#41 H_D#42 H_D#43 H_D#44 H_D#45 H_D#46 H_D#47 Within 0.5" 25mils Spacing COMP0,2 --> 18mils COMP1,3 --> 5mils THERMDA A Y22 AB24 V24 V26 V23 T22 U25 U23 Y25 W22 Y23 W24 W25 AA23 AA24 AB25 Y26 AA26 U22 ZIF-SOCK478_1.27pitch-RH ZIF-SOCK478_1.27pitch-RH 19,21 U26B H_D#[63:0] IERR# H4 C1 F3 F4 G3 G2 IERR# 5 THERMAL STPCLK# LINT0 LINT1 SMI# RSVD[01] RSVD[02] RSVD[03] RSVD[04] RSVD[05] RSVD[06] RSVD[07] RSVD[08] RSVD[09] RSVD[10] BPM[0]# BPM[1]# BPM[2]# BPM[3]# PRDY# PREQ# TCK TDI TDO TMS TRST# DBR# H5 F21 E1 5 5 DATA GRP 2 CONTROL HIT# HITM# A[17]# A[18]# A[19]# A[20]# A[21]# A[22]# A[23]# A[24]# A[25]# A[26]# A[27]# A[28]# A[29]# A[30]# A[31]# A[32]# A[33]# A[34]# A[35]# ADSTB[1]# ICH 17 17 17 LOCK# H_ADS# H_BNR# H_BPRI# DATA GRP 1 5 Y2 U5 R3 W6 U4 Y5 U1 R4 T5 T3 W2 W5 Y4 U2 V4 W3 AA4 AB2 AA3 V1 IERR# INIT# RESET# RS[0]# RS[1]# RS[2]# TRDY# REQ[0]# REQ[1]# REQ[2]# REQ[3]# REQ[4]# ADDR GROUP 1 H_A#17 H_A#18 H_A#19 H_A#20 H_A#21 H_A#22 H_A#23 H_A#24 H_A#25 H_A#26 H_A#27 H_A#28 H_A#29 H_A#30 H_A#31 H_A#32 H_A#33 H_A#34 H_A#35 BR0# H1 E2 G5 DATA GRP 3 2 DEFER# DRDY# DBSY# XDP/ITP SIGNALS K3 H2 K2 J3 L1 ADS# BNR# BPRI# RESERVED H_REQ#0 H_REQ#1 H_REQ#2 H_REQ#3 H_REQ#4 H_ADSTB#0 A[3]# A[4]# A[5]# A[6]# A[7]# A[8]# A[9]# A[10]# A[11]# A[12]# A[13]# A[14]# A[15]# A[16]# ADSTB[0]# DATA GRP 0 J4 L5 L4 K5 M3 N2 J1 N3 P5 P2 L2 P4 P1 R1 M1 ADDR GROUP 0 5 H_A#3 H_A#4 H_A#5 H_A#6 H_A#7 H_A#8 H_A#9 H_A#10 H_A#11 H_A#12 H_A#13 H_A#14 H_A#15 H_A#16 D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 3 of 41 A B C D E V_CORE C196 C194 C182 C402 C213 C171 C168 C403 C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH 1 1 U26D V_CORE V_CORE V_CORE U26C AB20 AB7 AC7 AC9 AC12 AC13 AC15 AC17 AC18 AD7 AD9 AD10 AD12 AD14 AD15 AD17 AD18 AE9 AE10 AE12 AE13 AE15 AE17 AE18 AE20 AF9 AF10 AF12 AF14 AF15 AF17 AF18 AF20 C407 C412 C419 C409 C165 C174 C195 C183 C197 C203 V_CORE C208 (2.5A) C188 C187 C173 C164 C202 C207 C406 C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH X_C22U6.3X50805-RH X_C22U6.3X50805-RH 3 Trace > 20 Place Cap close to pin +1_5VRUN (130mA) C428 34 34 34 34 34 34 34 C429 V_CORE C0.01U25X0402 C10U6.3X50805-1 VTT close to cpu socket R194 100R1%0402 VCCSENSE 34 VSSSENSE 34 C212 C210 Trace : 18/7/50 R195 C211 C162 C160 C163 1 CPU_VID0 CPU_VID1 CPU_VID2 CPU_VID3 CPU_VID4 CPU_VID5 CPU_VID6 C145 X_C220U2.5SP-LF 4 100R1%0402 Trace width = 18mils Trace spacing = 7mils other spacing = 50mils length matched within 25mils Place R close to CPU within 1" MSI CORPORATION Title Merom-2 (POWER/GND) Size Date: B C166 VTT Document Number Custom A C414 C22U6.3X50805-RH X_C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH X_C22U6.3X50805-RH ZIF-SOCK478_1.27pitch-RH . ZIF-SOCK478_1.27pitch-RH . C420 2 AF7 AE7 C415 2 AD6 AF5 AE5 AF4 AE3 AF3 AE2 C413 V_CORE G21 V6 J6 K6 M6 J21 K21 M21 N21 N6 R21 R6 T21 T6 V21 W21 B26 C26 C410 X_C22U6.3X50805-RH X_C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C22U6.3X50805-RH C0.1U10X0402 VCC[068] VCC[001] VCC[069] VCC[002] VCC[070] VCC[003] VCC[071] VCC[004] VCC[072] VCC[005] VCC[073] VCC[006] VCC[074] VCC[007] VCC[075] VCC[008] VCC[076] VCC[009] VCC[077] VCC[010] VCC[078] VCC[011] VCC[079] VCC[012] VCC[080] VCC[013] VCC[081] VCC[014] VCC[082] VCC[015] VCC[083] VCC[016] VCC[084] VCC[017] VCC[085] VCC[018] VCC[086] VCC[019] VCC[087] VCC[020] VCC[088] VCC[021] VCC[089] VCC[022] VCC[090] VCC[023] VCC[091] VCC[024] VCC[092] VCC[025] VCC[093] VCC[026] VCC[094] VCC[027] VCC[095] VCC[028] VCC[096] VCC[029] VCC[097] VCC[030] VCC[098] VCC[031] VCC[099] VCC[032] VCC[100] VCC[033] VCC[034] VCCP[01] VCC[035] VCCP[02] VCC[036] VCCP[03] VCC[037] VCCP[04] VCC[038] VCCP[05] VCC[039] VCCP[06] VCC[040] VCCP[07] VCC[041] VCCP[08] VCC[042] VCCP[09] VCC[043] VCCP[10] VCC[044] VCCP[11] VCC[045] VCCP[12] VCC[046] VCCP[13] VCC[047] VCCP[14] VCC[048] VCCP[15] VCC[049] VCCP[16] VCC[050] VCC[051] VCCA[01] VCC[052] VCCA[02] VCC[053] VCC[054] VID[0] VCC[055] VID[1] VCC[056] VID[2] VCC[057] VID[3] VCC[058] VID[4] VCC[059] VID[5] VCC[060] VID[6] VCC[061] VCC[062] VCC[063] VCC[064] VCCSENSE VCC[065] VCC[066] VCC[067] VSSSENSE C0.1U10X0402 A7 A9 A10 A12 A13 A15 A17 A18 A20 B7 B9 B10 B12 B14 B15 B17 B18 B20 C9 C10 C12 C13 C15 C17 C18 D9 D10 D12 D14 D15 D17 D18 E7 E9 E10 E12 E13 E15 E17 E18 E20 F7 F9 F10 F12 F14 F15 F17 F18 F20 AA7 AA9 AA10 AA12 AA13 AA15 AA17 AA18 AA20 AB9 AC10 AB10 AB12 AB14 AB15 AB17 AB18 C0.1U10X0402 (41A) C0.1U10X0402 P6 P21 P24 R2 R5 R22 R25 T1 T4 T23 T26 U3 U6 U21 U24 V2 V5 V22 V25 W1 W4 W23 W26 Y3 Y6 Y21 Y24 AA2 AA5 AA8 AA11 AA14 AA16 AA19 AA22 AA25 AB1 AB4 AB8 AB11 AB13 AB16 AB19 AB23 AB26 AC3 AC6 AC8 AC11 AC14 AC16 AC19 AC21 AC24 AD2 AD5 AD8 AD11 AD13 AD16 AD19 AD22 AD25 AE1 AE4 AE8 AE11 AE14 AE16 AE19 AE23 AE26 A2 AF6 AF8 AF11 AF13 AF16 AF19 AF21 A25 AF25 + 4 VSS[082] VSS[083] VSS[084] VSS[085] VSS[086] VSS[087] VSS[088] VSS[089] VSS[090] VSS[091] VSS[092] VSS[093] VSS[094] VSS[095] VSS[096] VSS[097] VSS[098] VSS[099] VSS[100] VSS[101] VSS[102] VSS[103] VSS[104] VSS[105] VSS[106] VSS[107] VSS[108] VSS[109] VSS[110] VSS[111] VSS[112] VSS[113] VSS[114] VSS[115] VSS[116] VSS[117] VSS[118] VSS[119] VSS[120] VSS[121] VSS[122] VSS[123] VSS[124] VSS[125] VSS[126] VSS[127] VSS[128] VSS[129] VSS[130] VSS[131] VSS[132] VSS[133] VSS[134] VSS[135] VSS[136] VSS[137] VSS[138] VSS[139] VSS[140] VSS[141] VSS[142] VSS[143] VSS[144] VSS[145] VSS[146] VSS[147] VSS[148] VSS[149] VSS[150] VSS[151] VSS[152] VSS[153] VSS[154] VSS[155] VSS[156] VSS[157] VSS[158] VSS[159] VSS[160] VSS[161] VSS[162] VSS[163] C0.1U10X0402 3 VSS[001] VSS[002] VSS[003] VSS[004] VSS[005] VSS[006] VSS[007] VSS[008] VSS[009] VSS[010] VSS[011] VSS[012] VSS[013] VSS[014] VSS[015] VSS[016] VSS[017] VSS[018] VSS[019] VSS[020] VSS[021] VSS[022] VSS[023] VSS[024] VSS[025] VSS[026] VSS[027] VSS[028] VSS[029] VSS[030] VSS[031] VSS[032] VSS[033] VSS[034] VSS[035] VSS[036] VSS[037] VSS[038] VSS[039] VSS[040] VSS[041] VSS[042] VSS[043] VSS[044] VSS[045] VSS[046] VSS[047] VSS[048] VSS[049] VSS[050] VSS[051] VSS[052] VSS[053] VSS[054] VSS[055] VSS[056] VSS[057] VSS[058] VSS[059] VSS[060] VSS[061] VSS[062] VSS[063] VSS[064] VSS[065] VSS[066] VSS[067] VSS[068] VSS[069] VSS[070] VSS[071] VSS[072] VSS[073] VSS[074] VSS[075] VSS[076] VSS[077] VSS[078] VSS[079] VSS[080] VSS[081] C0.1U10X0402 2 A4 A8 A11 A14 A16 A19 A23 AF2 B6 B8 B11 B13 B16 B19 B21 B24 C5 C8 C11 C14 C16 C19 C2 C22 C25 D1 D4 D8 D11 D13 D16 D19 D23 D26 E3 E6 E8 E11 E14 E16 E19 E21 E24 F5 F8 F11 F13 F16 F19 F2 F22 F25 G4 G1 G23 G26 H3 H6 H21 H24 J2 J5 J22 J25 K1 K4 K23 K26 L3 L6 L21 L24 M2 M5 M22 M25 N1 N4 N23 N26 P3 C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 4 of 41 A B C D U27A H_D#[63:0] H_D#0 H_D#1 H_D#2 H_D#3 H_D#4 H_D#5 H_D#6 H_D#7 H_D#8 H_D#9 H_D#10 H_D#11 H_D#12 H_D#13 H_D#14 H_D#15 H_D#16 H_D#17 H_D#18 H_D#19 H_D#20 H_D#21 H_D#22 H_D#23 H_D#24 H_D#25 H_D#26 H_D#27 H_D#28 H_D#29 H_D#30 H_D#31 H_D#32 H_D#33 H_D#34 H_D#35 H_D#36 H_D#37 H_D#38 H_D#39 H_D#40 H_D#41 H_D#42 H_D#43 H_D#44 H_D#45 H_D#46 H_D#47 H_D#48 H_D#49 H_D#50 H_D#51 H_D#52 H_D#53 H_D#54 H_D#55 H_D#56 H_D#57 H_D#58 H_D#59 H_D#60 H_D#61 H_D#62 H_D#63 1 VTT R366 221R1%0402 H_SWING R365 100R1%0402 C395 Place C0.1U10X0402 Cap close to pin 2 Trace : 8 mils H_RCOMP R367 24.9R1%0402 Trace to pin within 0.5" Spacing 25mils VTT R376 3 54.9R1%0402 H_SCOMP VTT E2 G2 G7 M6 H7 H3 G4 F3 N8 H2 M10 N12 N9 H5 P13 K9 M2 W10 Y8 V4 M3 J1 N5 N3 W6 W9 N2 Y7 Y9 P4 W3 N1 AD12 AE3 AD9 AC9 AC7 AC14 AD11 AC11 AB2 AD7 AB1 Y3 AC6 AE2 AC5 AG3 AJ9 AH8 AJ14 AE9 AE11 AH12 AJ5 AH5 AJ6 AE7 AJ7 AJ2 AE5 AJ3 AH2 AH13 H_D#_0 H_D#_1 H_D#_2 H_D#_3 H_D#_4 H_D#_5 H_D#_6 H_D#_7 H_D#_8 H_D#_9 H_D#_10 H_D#_11 H_D#_12 H_D#_13 H_D#_14 H_D#_15 H_D#_16 H_D#_17 H_D#_18 H_D#_19 H_D#_20 H_D#_21 H_D#_22 H_D#_23 H_D#_24 H_D#_25 H_D#_26 H_D#_27 H_D#_28 H_D#_29 H_D#_30 H_D#_31 H_D#_32 H_D#_33 H_D#_34 H_D#_35 H_D#_36 H_D#_37 H_D#_38 H_D#_39 H_D#_40 H_D#_41 H_D#_42 H_D#_43 H_D#_44 H_D#_45 H_D#_46 H_D#_47 H_D#_48 H_D#_49 H_D#_50 H_D#_51 H_D#_52 H_D#_53 H_D#_54 H_D#_55 H_D#_56 H_D#_57 H_D#_58 H_D#_59 H_D#_60 H_D#_61 H_D#_62 H_D#_63 H_A#_3 H_A#_4 H_A#_5 H_A#_6 H_A#_7 H_A#_8 H_A#_9 H_A#_10 H_A#_11 H_A#_12 H_A#_13 H_A#_14 H_A#_15 H_A#_16 H_A#_17 H_A#_18 H_A#_19 H_A#_20 H_A#_21 H_A#_22 H_A#_23 H_A#_24 H_A#_25 H_A#_26 H_A#_27 H_A#_28 H_A#_29 H_A#_30 H_A#_31 H_A#_32 H_A#_33 H_A#_34 H_A#_35 HOST 3 B3 C2 H_SCOMP H_SCOMP# W1 W2 54.9R1%0402 VTT H_SCOMP# 3 3 R359 H_CPURST# H_CPUSLP# B6 E5 H_DSTBN#_0 H_DSTBN#_1 H_DSTBN#_2 H_DSTBN#_3 H_DSTBP#_0 H_DSTBP#_1 H_DSTBP#_2 H_DSTBP#_3 H_SWING H_RCOMP H_REQ#_0 H_REQ#_1 H_REQ#_2 H_REQ#_3 H_REQ#_4 H_SCOMP H_SCOMP# H_CPURST# H_CPUSLP# H_RS#_0 H_RS#_1 H_RS#_2 1KR1%0402 4 H_AVREF R363 0R0402 H_DVREF B9 A9 H_A#3 H_A#4 H_A#5 H_A#6 H_A#7 H_A#8 H_A#9 H_A#10 H_A#11 H_A#12 H_A#13 H_A#14 H_A#15 H_A#16 H_A#17 H_A#18 H_A#19 H_A#20 H_A#21 H_A#22 H_A#23 H_A#24 H_A#25 H_A#26 H_A#27 H_A#28 H_A#29 H_A#30 H_A#31 H_A#32 H_A#33 H_A#34 H_A#35 G12 H17 G20 C8 E8 F12 D6 C10 AM5 AM7 H8 K7 E4 C6 G10 B7 H_A#[35:3] 1 2 H_ADS# 3 H_ADSTB#0 3 H_ADSTB#1 3 H_BNR# 3 H_BPRI# 3 H_BREQ# 3 H_DEFER# 3 H_DBSY# 3 CLK_MCH_BCLK 15 CLK_MCH_BCLK# 15 H_DPWR# 3 H_DRDY# 3 H_HIT# 3 H_HITM# 3 H_LOCK# 3 H_TRDY# 3 K5 L2 AD13 AE13 H_DINV#0 H_DINV#1 H_DINV#2 H_DINV#3 M7 K3 AD2 AH11 H_DSTBN#0 H_DSTBN#1 H_DSTBN#2 H_DSTBN#3 L7 K2 AC2 AJ10 H_DSTBP#0 H_DSTBP#1 H_DSTBP#2 H_DSTBP#3 M14 E13 A11 H13 B12 H_REQ#0 H_REQ#1 H_REQ#2 H_REQ#3 H_REQ#4 E12 D7 D8 H_RS#0 H_RS#1 H_RS#2 H_DINV#0 H_DINV#1 H_DINV#2 H_DINV#3 3 3 3 3 H_DSTBN#0 H_DSTBN#1 H_DSTBN#2 H_DSTBN#3 3 3 3 3 H_DSTBP#0 3 H_DSTBP#1 3 H_DSTBP#2 3 H_DSTBP#3 3 H_REQ#[4:0] 3 H_RS#[2:0] 2KR1%0402 C393 C0.1U10X0402 3 4 H_AVREF H_DVREF MSI CORPORATION CRESTLINE_1p0 R360 3 3 H_DINV#_0 H_DINV#_1 H_DINV#_2 H_DINV#_3 R375 H_SWING H_RCOMP H_ADS# H_ADSTB#_0 H_ADSTB#_1 H_BNR# H_BPRI# H_BREQ# H_DEFER# H_DBSY# HPLL_CLK HPLL_CLK# H_DPWR# H_DRDY# H_HIT# H_HITM# H_LOCK# H_TRDY# J13 B11 C11 M11 C15 F16 L13 G17 C14 K16 B13 L16 J17 B14 K19 P15 R17 B16 H20 L19 D17 M17 N16 J19 B18 E19 B17 B15 E17 C18 A19 B19 N19 E Place Cap close to pin Title Trace : 10 mils Size CRESTLINE-1 (HOST BUS) B Date: A [email protected] GRATIS - FOR FREE B C D Document Number Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 5 of 41 A B C D E +1_8VDIMM U27B SM_CKE_0 SM_CKE_1 SM_CKE_3 SM_CKE_4 SM_CS#_0 SM_CS#_1 SM_CS#_2 SM_CS#_3 SM_ODT_0 SM_ODT_1 SM_ODT_2 SM_ODT_3 SM_RCOMP SM_RCOMP# SM_RCOMP_VOH SM_RCOMP_VOL SM_VREF_0 SM_VREF_1 DPLL_REF_CLK DPLL_REF_CLK# DPLL_REF_SSCLK DPLL_REF_SSCLK# PEG_CLK PEG_CLK# CFG_8 CFG_9 TP69 TP55 CFG_12 CFG_13 TP73 CFG_16 TP72 TP71 R192 0R0402 R216 0R0402 R189 0R0402 PM_BMBUSY# G41 PM_DPRSTP#_R L39 PM_EXTTS#0 L36 PM_EXTTS#1 J36 NB_PWRGD AW49 NB_RST# AV20 PM_THRMTRIP# N20 DPRSLPVR_R G36 R193 R203 R199 10KR0402 10KR0402 10KR0402 CLK_MCH_OE# PM_EXTTS#0 PM_EXTTS#1 NC_1 NC_2 NC_3 NC_4 NC_5 NC_6 NC_7 NC_8 NC_9 NC_10 NC_11 NC_12 NC_13 NC_14 NC_15 NC_16 NC +3VRUN BJ51 BK51 BK50 BL50 BL49 BL3 BL2 BK1 BJ1 E1 A5 C51 B50 A50 A49 BK2 PM_BM_BUSY# PM_DPRSTP# PM_EXT_TS#_0 PM_EXT_TS#_1 PWROK RSTIN# THERMTRIP# DPRSLPVR PM 19 PM_BMBUSY# 3,17,34 H_DPRSTP# 11 PM_EXTTS#0 12 PM_EXTTS#1 19,34 IMVP_PWRGD 18 NB_RST# 3,17 PM_THRMTRIP# 19,34 PM_DPRSLPVR SM_RCOMP_VOH 11 11 12 12 R380 BE29 AY32 BD39 BG37 M_CKE0 M_CKE1 M_CKE3 M_CKE4 11,13 11,13 12,13 12,13 BG20 BK16 BG16 BE13 M_CS#0 M_CS#1 M_CS#2 M_CS#3 11,13 11,13 12,13 12,13 BH18 BJ15 BJ14 BE16 M_ODT0 M_ODT1 M_ODT2 M_ODT3 11,13 11,13 12,13 12,13 DMI_TXP_0 DMI_TXP_1 DMI_TXP_2 DMI_TXP_3 C425 C0.01U25X0402 C432 2.2U6.3X L_BKLT_CTRL TP57 TP50 L_CTRL_CLK L_CTRL_DATA R202 2.37KR1%0402 LVDS_IBG TP70 LVDS_VBG +1_8VDIMM Place Cap close to pin 16 LVDS_TXLCLK16 LVDS_TXLCLK+ TP48 TP58 R214 10KR1%0402 SM_VREF AR49 AW4 TP67 16 LVDS_DDC_CLK 16 LVDS_DDC_DATA 16 LVDS_VDD_EN 1KR0.1% J40 H39 E39 E40 C37 D35 K40 L41 L43 N41 N40 D46 C45 D44 E42 16 LVDS_TXL016 LVDS_TXL116 LVDS_TXL2- G51 E51 F49 16 LVDS_TXL0+ 16 LVDS_TXL1+ 16 LVDS_TXL2+ G50 E50 F48 Trace : 10 mils B42 C42 H48 H47 DREFCLK DREFCLK# DREFSSCLK DREFSSCLK# K44 K45 CLK_PCIE_3GPLL CLK_PCIE_3GPLL# AN47 AJ38 AN42 AN46 DMI_TXN0 DMI_TXN1 DMI_TXN2 DMI_TXN3 18 18 18 18 AM47 AJ39 AN41 AN45 DMI_TXP0 DMI_TXP1 DMI_TXP2 DMI_TXP3 18 18 18 18 AJ46 AJ41 AM40 AM44 DMI_RXN0 DMI_RXN1 DMI_RXN2 DMI_RXN3 18 18 18 18 AJ47 AJ42 AM39 AM43 DMI_RXP0 DMI_RXP1 DMI_RXP2 DMI_RXP3 18 18 18 18 C204 R215 C0.1U10X0402 C0.1U10X0402 15 15 15 15 10KR1%0402 15 15 +1_8VDIMM R187 R191 R184 Trace : 8 mils E35 A39 C38 B39 E36 GFX_VID_0 GFX_VID_1 GFX_VID_2 GFX_VID_3 GFX_VR_EN TP60 TP137 TP130 G44 B47 B45 TP64 TP139 TP136 E44 A47 A45 X_150R1%0402 X_150R1%0402 X_150R1%0402 MCH_TVA_DAC MCH_TVB_DAC MCH_TVC_DAC R377 E27 G27 K27 F27 J27 L27 20R1% SM_RCOMP SM_RCOMP# M35 P33 VCC_PEG L_BKLT_CTRL L_BKLT_EN L_CTRL_CLK L_CTRL_DATA L_DDC_CLK L_DDC_DATA L_VDD_EN LVDS_IBG LVDS_VBG LVDS_VREFH LVDS_VREFL LVDSA_CLK# LVDSA_CLK LVDSB_CLK# LVDSB_CLK LVDSA_DATA#_0 LVDSA_DATA#_1 LVDSA_DATA#_2 LVDSA_DATA_0 LVDSA_DATA_1 LVDSA_DATA_2 LVDSB_DATA#_0 LVDSB_DATA#_1 LVDSB_DATA#_2 LVDSB_DATA_0 LVDSB_DATA_1 LVDSB_DATA_2 TVA_DAC TVB_DAC TVC_DAC TVA_RTN TVB_RTN TVC_RTN TV_DCONSEL_0 TV_DCONSEL_1 20R1% 16 VGA_B_GM RG5 150R1%0402 16 VGA_G_GM RG4 150R1%0402 16 VGA_R_GM RG1 150R1%0402 35 35 35 35 35 16 VGA_CLK 16 VGA_DATA 16 VGA_HSYNC_GM 16 VGA_VSYNC_GM +1_25VRUN RG2 39R0402 RG3 39R0402 H32 G32 K29 J29 F29 E29 K33 G35 F33 C32 E33 CRT_BLUE CRT_BLUE# CRT_GREEN CRT_GREEN# CRT_RED CRT_RED# CRT_DDC_CLK CRT_DDC_DATA CRT_HSYNC CRT_TVO_IREF CRT_VSYNC R364 CL_CLK CL_DATA CL_PWROK CL_RST# CL_VREF AM49 AK50 AT43 AN49 AM50 CL_CLK0 CL_DATA0 MPWROK CL_RST#0 R213 1KR1%0402 19 19 19,21 19 SDVO_CTRL_CLK SDVO_CTRL_DATA CLK_REQ# ICH_SYNC# TEST_1 TEST_2 PEG_RX#_0 PEG_RX#_1 PEG_RX#_2 PEG_RX#_3 PEG_RX#_4 PEG_RX#_5 PEG_RX#_6 PEG_RX#_7 PEG_RX#_8 PEG_RX#_9 PEG_RX#_10 PEG_RX#_11 PEG_RX#_12 PEG_RX#_13 PEG_RX#_14 PEG_RX#_15 PEG_RX_0 PEG_RX_1 PEG_RX_2 PEG_RX_3 PEG_RX_4 PEG_RX_5 PEG_RX_6 PEG_RX_7 PEG_RX_8 PEG_RX_9 PEG_RX_10 PEG_RX_11 PEG_RX_12 PEG_RX_13 PEG_RX_14 PEG_RX_15 PEG_TX#_0 PEG_TX#_1 PEG_TX#_2 PEG_TX#_3 PEG_TX#_4 PEG_TX#_5 PEG_TX#_6 PEG_TX#_7 PEG_TX#_8 PEG_TX#_9 PEG_TX#_10 PEG_TX#_11 PEG_TX#_12 PEG_TX#_13 PEG_TX#_14 PEG_TX#_15 PEG_TX_0 PEG_TX_1 PEG_TX_2 PEG_TX_3 PEG_TX_4 PEG_TX_5 PEG_TX_6 PEG_TX_7 PEG_TX_8 PEG_TX_9 PEG_TX_10 PEG_TX_11 PEG_TX_12 PEG_TX_13 PEG_TX_14 PEG_TX_15 R373 N43 PEG_COMP M43 J51 L51 N47 T45 T50 U40 Y44 Y40 AB51 W49 AD44 AD40 AG46 AH49 AG45 AG41 J50 L50 M47 U44 T49 T41 W45 W41 AB50 Y48 AC45 AC41 AH47 AG49 AH45 AG42 NB_RXN1 NB_RXP1 24.9R1%0402 NB_RXN1 14 NB_RXP1 14 2 N45 U39 U47 N51 R50 T42 Y43 W46 W38 AD39 AC46 AC49 AC42 AH39 AE49 AH44 NB_TXN0 NB_TXN1 NB_TXN2 NB_TXN3 CG9 CG7 CG2 CG4 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 M45 T38 T46 N50 R51 U43 W42 Y47 Y39 AC38 AD47 AC50 AD43 AG39 AE50 AH43 NB_TXP0 NB_TXP1 NB_TXP2 NB_TXP3 CG6 CG8 CG3 CG5 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 SDVOB_RedSDVOB_GreenSDVOB_BlueSDVOB_Clk- 14 14 14 14 SDVOB_Red+ 14 SDVOB_Green+ 14 SDVOB_Blue+ 14 SDVOB_Clk+ 14 3 1.3KR0.1%0402 CRESTLINE_1p0 CL_VREF C198 C0.1U10X0402 H35 K36 G39 G40 PEG_COMPI PEG_COMPO R378 Trace within 0.5" GFX_VID_0 GFX_VID_1 GFX_VID_2 GFX_VID_3 GFX_VR_EN U27C 16 LVDS_BLON R212 392R1% Place Cap close to pin SDVO_CTRLCLK 14 SDVO_CTRLDATA 14 CLK_MCH_OE# 15 MCH_ICH_SYNC# 19 TEST_1 TEST_2 A37 R32 GFX_VID_[3:0]=0100 -->1.1845V CRESTLINE_1p0 4 1 Trace : 8 mils R382 SM_RCOMP_VOH SM_RCOMP_VOL BK31 BL31 C433 2.2U6.3X SM_RCOMP_VOL SM_RCOMP SM_RCOMP# BL15 BK14 C426 C0.01U25X0402 3.01KR1% VGA 3 CFG_19 CFG_20 DMI TP65 TP133 1KR0402 DMI_TXN_0 DMI_TXN_1 DMI_TXN_2 DMI_TXN_3 GRAPHICS VID CFG_5 CFG TP49 DMI_RXP_0 DMI_RXP_1 DMI_RXP_2 DMI_RXP_3 ME R204 CFG_0 CFG_1 CFG_2 CFG_3 CFG_4 CFG_5 CFG_6 CFG_7 CFG_8 CFG_9 CFG_10 CFG_11 CFG_12 CFG_13 CFG_14 CFG_15 CFG_16 CFG_17 CFG_18 CFG_19 CFG_20 MISC MCH_BSEL2 P27 N27 N24 C21 C23 F23 N23 G23 J20 C20 R24 L23 J23 E23 E20 K23 M20 M24 L32 N33 L35 M_CLK_DDR#0 M_CLK_DDR#1 M_CLK_DDR#3 M_CLK_DDR#4 Place Cap close to pin 1KR0.1% TV MCH_BSEL0 MCH_BSEL1 AW30 BA23 AW25 AW23 R383 11 11 12 12 C209 DMI_RXN_0 DMI_RXN_1 DMI_RXN_2 DMI_RXN_3 15 15 M_CLK_DDR0 M_CLK_DDR1 M_CLK_DDR3 M_CLK_DDR4 GRAPHICS MUXING RSVD20 RSVD21 RSVD22 RSVD23 RSVD24 RSVD25 RSVD26 RSVD27 RSVD28 RSVD29 RSVD30 RSVD31 RSVD32 RSVD33 RSVD34 RSVD35 RSVD36 RSVD37 RSVD38 RSVD39 RSVD40 RSVD41 RSVD42 RSVD43 RSVD44 RSVD45 SM_CK#_0 SM_CK#_1 SM_CK#_3 SM_CK#_4 AV29 BB23 BA25 AV23 PCI-EXPRESS 2 H10 B51 BJ20 BK22 BF19 BH20 BK18 BJ18 BF23 BG23 BC23 BD24 BJ29 BE24 BH39 AW20 BK20 C48 D47 B44 C44 A35 B37 B36 B34 C34 SM_CK_0 SM_CK_1 SM_CK_3 SM_CK_4 DDR M_A_A14 M_B_A14 RSVD20 RSVD21 RSVD22 RSVD23 RSVD24 RSVD25 RSVD26 RSVD27 RSVD28 RSVD29 RSVD30 RSVD31 RSVD32 RSVD33 RSVD34 RSVD35 RSVD36 RSVD37 RSVD38 RSVD39 RSVD40 RSVD41 RSVD42 RSVD43 RSVD44 RSVD45 RSVD1 RSVD2 RSVD3 RSVD4 RSVD5 RSVD6 RSVD7 RSVD8 RSVD9 RSVD10 RSVD11 RSVD12 RSVD13 RSVD14 LVDS 11,13 12,13 R229 R230 TP62 TP47 TP142 TP100 TP94 TP99 TP143 TP144 TP95 TP97 TP91 TP93 X_0R0402 X_0R0402 TP96 TP88 TP141 TP52 TP56 TP135 TP131 TP128 TP140 TP134 TP132 TP138 P36 P37 R35 N35 AR12 AR13 AM12 AN13 J12 AR37 AM36 AL36 AM37 D20 CLK 1 RSVD1 RSVD2 RSVD3 RSVD4 RSVD5 RSVD6 RSVD7 RSVD8 RSVD9 RSVD10 RSVD11 RSVD12 RSVD13 RSVD14 RSVD TP76 TP77 TP75 TP74 TP85 TP83 TP82 TP84 TP66 TP81 TP80 TP78 TP79 TP129 VTT R205 20KR0402-2 R362 0R0402 RN7 1 3 5 7 R179 8P4R-2.2KR 2 4 6 8 100KR0402 4 GFX_VID_1 GFX_VID_0 GFX_VID_2 GFX_VID_3 R180 +3VRUN 30KR0402 MSI CORPORATION Strapping Configulation CFG5 (Default=High) CFG9 (Default=High) CFG16 (Default=High) CFG19 (Default=Low) CFG20 (Default=Low) DMI*4 PCIE Graphics Lane: Normal Operation Dynamic ODT Enabled DMI Lane Reversal: Normal Operation Only SDVO or PCIE is operational Title GFX_VR_EN CRESTLINE-2 (DMI/VGA) Size Workaround : fixing "system may not boot". Date: A B C Document Number Custom D Rev 0B MS-1221 Wednesday, September 06, 2006 E Sheet 6 of 41 12 M_B_DQ[63:0] 3 SA_CAS# MEMORY A SA_DM_0 SA_DM_1 SA_DM_2 SA_DM_3 SA_DM_4 SA_DM_5 SA_DM_6 SA_DM_7 SYSTEM 2 SA_DQ_0 SA_DQ_1 SA_DQ_2 SA_DQ_3 SA_DQ_4 SA_DQ_5 SA_DQ_6 SA_DQ_7 SA_DQ_8 SA_DQ_9 SA_DQ_10 SA_DQ_11 SA_DQ_12 SA_DQ_13 SA_DQ_14 SA_DQ_15 SA_DQ_16 SA_DQ_17 SA_DQ_18 SA_DQ_19 SA_DQ_20 SA_DQ_21 SA_DQ_22 SA_DQ_23 SA_DQ_24 SA_DQ_25 SA_DQ_26 SA_DQ_27 SA_DQ_28 SA_DQ_29 SA_DQ_30 SA_DQ_31 SA_DQ_32 SA_DQ_33 SA_DQ_34 SA_DQ_35 SA_DQ_36 SA_DQ_37 SA_DQ_38 SA_DQ_39 SA_DQ_40 SA_DQ_41 SA_DQ_42 SA_DQ_43 SA_DQ_44 SA_DQ_45 SA_DQ_46 SA_DQ_47 SA_DQ_48 SA_DQ_49 SA_DQ_50 SA_DQ_51 SA_DQ_52 SA_DQ_53 SA_DQ_54 SA_DQ_55 SA_DQ_56 SA_DQ_57 SA_DQ_58 SA_DQ_59 SA_DQ_60 SA_DQ_61 SA_DQ_62 SA_DQ_63 SA_BS_0 SA_BS_1 SA_BS_2 DDR 1 AR43 AW44 BA45 AY46 AR41 AR45 AT42 AW47 BB45 BF48 BG47 BJ45 BB47 BG50 BH49 BE45 AW43 BE44 BG42 BE40 BF44 BH45 BG40 BF40 AR40 AW40 AT39 AW36 AW41 AY41 AV38 AT38 AV13 AT13 AW11 AV11 AU15 AT11 BA13 BA11 BE10 BD10 BD8 AY9 BG10 AW9 BD7 BB9 BB5 AY7 AT5 AT7 AY6 BB7 AR5 AR8 AR9 AN3 AM8 AN10 AT9 AN9 AM9 AN11 SA_DQS_0 SA_DQS_1 SA_DQS_2 SA_DQS_3 SA_DQS_4 SA_DQS_5 SA_DQS_6 SA_DQS_7 SA_DQS#_0 SA_DQS#_1 SA_DQS#_2 SA_DQS#_3 SA_DQS#_4 SA_DQS#_5 SA_DQS#_6 SA_DQS#_7 SA_MA_0 SA_MA_1 SA_MA_2 SA_MA_3 SA_MA_4 SA_MA_5 SA_MA_6 SA_MA_7 SA_MA_8 SA_MA_9 SA_MA_10 SA_MA_11 SA_MA_12 SA_MA_13 SA_RAS# SA_RCVEN# SA_WE# BB19 BK19 BF29 M_A_BS0 M_A_BS1 M_A_BS2 M_A_CAS# BL17 AT45 BD44 BD42 AW38 AW13 BG8 AY5 AN6 M_A_DM0 M_A_DM1 M_A_DM2 M_A_DM3 M_A_DM4 M_A_DM5 M_A_DM6 M_A_DM7 AT46 BE48 BB43 BC37 BB16 BH6 BB2 AP3 AT47 BD47 BC41 BA37 BA16 BH7 BC1 AP2 M_A_DQS0 M_A_DQS1 M_A_DQS2 M_A_DQS3 M_A_DQS4 M_A_DQS5 M_A_DQS6 M_A_DQS7 M_A_DQS#0 M_A_DQS#1 M_A_DQS#2 M_A_DQS#3 M_A_DQS#4 M_A_DQS#5 M_A_DQS#6 M_A_DQS#7 BJ19 BD20 BK27 BH28 BL24 BK28 BJ27 BJ25 BL28 BA28 BC19 BE28 BG30 BJ16 M_A_A0 M_A_A1 M_A_A2 M_A_A3 M_A_A4 M_A_A5 M_A_A6 M_A_A7 M_A_A8 M_A_A9 M_A_A10 M_A_A11 M_A_A12 M_A_A13 BE18 AY20 SA_RCVEN# 11,13 11,13 11,13 11,13 M_A_DM[7:0] 11 M_A_DQS[7:0] 11 M_A_DQS#[7:0] 11 M_A_A[13:0] M_A_RAS# 11,13 11,13 TP87 BA19 M_A_WE# 11,13 CRESTLINE_1p0 4 E U27E M_B_DQ0 M_B_DQ1 M_B_DQ2 M_B_DQ3 M_B_DQ4 M_B_DQ5 M_B_DQ6 M_B_DQ7 M_B_DQ8 M_B_DQ9 M_B_DQ10 M_B_DQ11 M_B_DQ12 M_B_DQ13 M_B_DQ14 M_B_DQ15 M_B_DQ16 M_B_DQ17 M_B_DQ18 M_B_DQ19 M_B_DQ20 M_B_DQ21 M_B_DQ22 M_B_DQ23 M_B_DQ24 M_B_DQ25 M_B_DQ26 M_B_DQ27 M_B_DQ28 M_B_DQ29 M_B_DQ30 M_B_DQ31 M_B_DQ32 M_B_DQ33 M_B_DQ34 M_B_DQ35 M_B_DQ36 M_B_DQ37 M_B_DQ38 M_B_DQ39 M_B_DQ40 M_B_DQ41 M_B_DQ42 M_B_DQ43 M_B_DQ44 M_B_DQ45 M_B_DQ46 M_B_DQ47 M_B_DQ48 M_B_DQ49 M_B_DQ50 M_B_DQ51 M_B_DQ52 M_B_DQ53 M_B_DQ54 M_B_DQ55 M_B_DQ56 M_B_DQ57 M_B_DQ58 M_B_DQ59 M_B_DQ60 M_B_DQ61 M_B_DQ62 M_B_DQ63 AP49 AR51 AW50 AW51 AN51 AN50 AV50 AV49 BA50 BB50 BA49 BE50 BA51 AY49 BF50 BF49 BJ50 BJ44 BJ43 BL43 BK47 BK49 BK43 BK42 BJ41 BL41 BJ37 BJ36 BK41 BJ40 BL35 BK37 BK13 BE11 BK11 BC11 BC13 BE12 BC12 BG12 BJ10 BL9 BK5 BL5 BK9 BK10 BJ8 BJ6 BF4 BH5 BG1 BC2 BK3 BE4 BD3 BJ2 BA3 BB3 AR1 AT3 AY2 AY3 AU2 AT2 SB_BS_0 SB_BS_1 SB_BS_2 SB_DQ_0 SB_DQ_1 SB_DQ_2 SB_DQ_3 SB_DQ_4 SB_DQ_5 SB_DQ_6 SB_DQ_7 SB_DQ_8 SB_DQ_9 SB_DQ_10 SB_DQ_11 SB_DQ_12 SB_DQ_13 SB_DQ_14 SB_DQ_15 SB_DQ_16 SB_DQ_17 SB_DQ_18 SB_DQ_19 SB_DQ_20 SB_DQ_21 SB_DQ_22 SB_DQ_23 SB_DQ_24 SB_DQ_25 SB_DQ_26 SB_DQ_27 SB_DQ_28 SB_DQ_29 SB_DQ_30 SB_DQ_31 SB_DQ_32 SB_DQ_33 SB_DQ_34 SB_DQ_35 SB_DQ_36 SB_DQ_37 SB_DQ_38 SB_DQ_39 SB_DQ_40 SB_DQ_41 SB_DQ_42 SB_DQ_43 SB_DQ_44 SB_DQ_45 SB_DQ_46 SB_DQ_47 SB_DQ_48 SB_DQ_49 SB_DQ_50 SB_DQ_51 SB_DQ_52 SB_DQ_53 SB_DQ_54 SB_DQ_55 SB_DQ_56 SB_DQ_57 SB_DQ_58 SB_DQ_59 SB_DQ_60 SB_DQ_61 SB_DQ_62 SB_DQ_63 SB_CAS# SB_DM_0 SB_DM_1 SB_DM_2 SB_DM_3 SB_DM_4 SB_DM_5 SB_DM_6 SB_DM_7 B U27D M_A_DQ0 M_A_DQ1 M_A_DQ2 M_A_DQ3 M_A_DQ4 M_A_DQ5 M_A_DQ6 M_A_DQ7 M_A_DQ8 M_A_DQ9 M_A_DQ10 M_A_DQ11 M_A_DQ12 M_A_DQ13 M_A_DQ14 M_A_DQ15 M_A_DQ16 M_A_DQ17 M_A_DQ18 M_A_DQ19 M_A_DQ20 M_A_DQ21 M_A_DQ22 M_A_DQ23 M_A_DQ24 M_A_DQ25 M_A_DQ26 M_A_DQ27 M_A_DQ28 M_A_DQ29 M_A_DQ30 M_A_DQ31 M_A_DQ32 M_A_DQ33 M_A_DQ34 M_A_DQ35 M_A_DQ36 M_A_DQ37 M_A_DQ38 M_A_DQ39 M_A_DQ40 M_A_DQ41 M_A_DQ42 M_A_DQ43 M_A_DQ44 M_A_DQ45 M_A_DQ46 M_A_DQ47 M_A_DQ48 M_A_DQ49 M_A_DQ50 M_A_DQ51 M_A_DQ52 M_A_DQ53 M_A_DQ54 M_A_DQ55 M_A_DQ56 M_A_DQ57 M_A_DQ58 M_A_DQ59 M_A_DQ60 M_A_DQ61 M_A_DQ62 M_A_DQ63 D MEMORY 11 M_A_DQ[63:0] C SYSTEM B DDR A SB_DQS_0 SB_DQS_1 SB_DQS_2 SB_DQS_3 SB_DQS_4 SB_DQS_5 SB_DQS_6 SB_DQS_7 SB_DQS#_0 SB_DQS#_1 SB_DQS#_2 SB_DQS#_3 SB_DQS#_4 SB_DQS#_5 SB_DQS#_6 SB_DQS#_7 SB_MA_0 SB_MA_1 SB_MA_2 SB_MA_3 SB_MA_4 SB_MA_5 SB_MA_6 SB_MA_7 SB_MA_8 SB_MA_9 SB_MA_10 SB_MA_11 SB_MA_12 SB_MA_13 SB_RAS# SB_RCVEN# SB_WE# AY17 BG18 BG36 BE17 AR50 BD49 BK45 BL39 BH12 BJ7 BF3 AW2 M_B_DM0 M_B_DM1 M_B_DM2 M_B_DM3 M_B_DM4 M_B_DM5 M_B_DM6 M_B_DM7 AT50 BD50 BK46 BK39 BJ12 BL7 BE2 AV2 AU50 BC50 BL45 BK38 BK12 BK7 BF2 AV3 M_B_DQS0 M_B_DQS1 M_B_DQS2 M_B_DQS3 M_B_DQS4 M_B_DQS5 M_B_DQS6 M_B_DQS7 M_B_DQS#0 M_B_DQS#1 M_B_DQS#2 M_B_DQS#3 M_B_DQS#4 M_B_DQS#5 M_B_DQS#6 M_B_DQS#7 BC18 BG28 BG25 AW17 BF25 BE25 BA29 BC28 AY28 BD37 BG17 BE37 BA39 BG13 M_B_A0 M_B_A1 M_B_A2 M_B_A3 M_B_A4 M_B_A5 M_B_A6 M_B_A7 M_B_A8 M_B_A9 M_B_A10 M_B_A11 M_B_A12 M_B_A13 M_B_BS0 M_B_BS1 M_B_BS2 M_B_CAS# 12,13 12,13 12,13 12,13 M_B_DM[7:0] 12 1 M_B_DQS[7:0] 12 M_B_DQS#[7:0] 12 M_B_A[13:0] 2 12,13 3 AV16 AY18 SB_RCVEN# M_B_RAS# 12,13 M_B_WE# 12,13 TP90 BC17 CRESTLINE_1p0 4 MSI CORPORATION Title CRESTLINE-3 (DDR) Size Document Number Custom Date: A [email protected] GRATIS - FOR FREE B C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 7 of 41 A B C D E VTT +VGFX_CORE 3 VCC_AXG_1 VCC_AXG_2 VCC_AXG_3 VCC_AXG_4 VCC_AXG_5 VCC_AXG_6 VCC_AXG_7 VCC_AXG_8 VCC_AXG_9 VCC_AXG_10 VCC_AXG_11 VCC_AXG_12 VCC_AXG_13 VCC_AXG_14 VCC_AXG_15 VCC_AXG_16 VCC_AXG_17 VCC_AXG_18 VCC_AXG_19 VCC_AXG_20 VCC_AXG_21 VCC_AXG_22 VCC_AXG_23 VCC_AXG_24 VCC_AXG_25 VCC_AXG_26 VCC_AXG_27 VCC_AXG_28 VCC_AXG_29 VCC_AXG_30 VCC_AXG_31 VCC_AXG_32 VCC_AXG_33 VCC_AXG_34 AW45 BC39 BE39 BD17 BD4 AW8 AT6 VCC_SM_LF1 VCC_SM_LF2 VCC_SM_LF3 VCC_SM_LF4 VCC_SM_LF5 VCC_SM_LF6 VCC_SM_LF7 C201 C0.1U10X0402 C177 C0.1U10X0402 C175 C0.1U10X0402 VSS NCTF VSS SCB C295 C151 C10U6.3X50805-1 C22U6.3X50805-RH C191 C170 C186 C176 C189 C0.22U6.3X50402 C0.22U6.3X50402 C178 C0.22U6.3X50402 C0.22U6.3X50402 C0.22U6.3X50402 +1_8VDIMM C232 C229 X_C220U2.5SP-LF C224 C10U6.3X50805-1 AL24 AL26 AL28 AM26 AM28 AM29 AM31 AM32 AM33 AP29 AP31 AP32 AP33 AL29 AL31 AL32 AR31 AR32 AR33 2 A3 B2 C1 BL1 BL51 A51 VSS_SCB1 VSS_SCB2 VSS_SCB3 VSS_SCB4 VSS_SCB5 VSS_SCB6 VTT VTT C0.22U6.3X50402 1 T27 T37 U24 U28 V31 V35 AA19 AB17 AB35 AD19 AD37 AF17 AF35 AK17 AM17 AM24 AP26 AP28 AR15 AR19 AR28 VSS_NCTF_1 VSS_NCTF_2 VSS_NCTF_3 VSS_NCTF_4 VSS_NCTF_5 VSS_NCTF_6 VSS_NCTF_7 VSS_NCTF_8 VSS_NCTF_9 VSS_NCTF_10 VSS_NCTF_11 VSS_NCTF_12 VSS_NCTF_13 VSS_NCTF_14 VSS_NCTF_15 VSS_NCTF_16 VSS_NCTF_17 VSS_NCTF_18 VSS_NCTF_19 VSS_NCTF_20 VSS_NCTF_21 POWER VCC_AXM_NCTF_1 VCC_AXM_NCTF_2 VCC_AXM_NCTF_3 VCC_AXM_NCTF_4 VCC_AXM_NCTF_5 VCC_AXM_NCTF_6 VCC_AXM_NCTF_7 VCC_AXM_NCTF_8 VCC_AXM_NCTF_9 VCC_AXM_NCTF_10 VCC_AXM_NCTF_11 VCC_AXM_NCTF_12 VCC_AXM_NCTF_13 VCC_AXM_NCTF_14 VCC_AXM_NCTF_15 VCC_AXM_NCTF_16 VCC_AXM_NCTF_17 VCC_AXM_NCTF_18 VCC_AXM_NCTF_19 VCC AXM X_C330U2-RH-1 VCC_NCTF_1 VCC_NCTF_2 VCC_NCTF_3 VCC_NCTF_4 VCC_NCTF_5 VCC_NCTF_6 VCC_NCTF_7 VCC_NCTF_8 VCC_NCTF_9 VCC_NCTF_10 VCC_NCTF_11 VCC_NCTF_12 VCC_NCTF_13 VCC_NCTF_14 VCC_NCTF_15 VCC_NCTF_16 VCC_NCTF_17 VCC_NCTF_18 VCC_NCTF_19 VCC_NCTF_20 VCC_NCTF_21 VCC_NCTF_22 VCC_NCTF_23 VCC_NCTF_24 VCC_NCTF_25 VCC_NCTF_26 VCC_NCTF_27 VCC_NCTF_28 VCC_NCTF_29 VCC_NCTF_30 VCC_NCTF_31 VCC_NCTF_32 VCC_NCTF_33 VCC_NCTF_34 VCC_NCTF_35 VCC_NCTF_36 VCC_NCTF_37 VCC_NCTF_38 VCC_NCTF_39 VCC_NCTF_40 VCC_NCTF_41 VCC_NCTF_42 VCC_NCTF_43 VCC_NCTF_44 VCC_NCTF_45 VCC_NCTF_46 VCC_NCTF_47 VCC_NCTF_48 VCC_NCTF_49 VCC_NCTF_50 VCC NCTF 1 2 C161 C1U10X + + 4 R20 T14 W13 W14 Y12 AA20 AA23 AA26 AA28 AB21 AB24 AB29 AC20 AC21 AC23 AC24 AC26 AC28 AC29 AD20 AD23 AD24 AD28 AF21 AF26 AA31 AH20 AH21 AH23 AH24 AH26 AD31 AJ20 AN14 C146 AB33 AB36 AB37 AC33 AC35 AC36 AD35 AD36 AF33 AF36 AH33 AH35 AH36 AH37 AJ33 AJ35 AK33 AK35 AK36 AK37 AD33 AJ36 AM35 AL33 AL35 AA33 AA35 AA36 AP35 AP36 AR35 AR36 Y32 Y33 Y35 Y36 Y37 T30 T34 T35 U29 U31 U32 U33 U35 U36 V32 V33 V36 V37 VCC AXM NCTF (7.7A) VCC GFX +VGFX_CORE +VGFX_CORE 1 VCC_SM_1 VCC_SM_2 VCC_SM_3 VCC_SM_4 VCC_SM_5 VCC_SM_6 VCC_SM_7 VCC_SM_8 VCC_SM_9 VCC_SM_10 VCC_SM_11 VCC_SM_12 VCC_SM_13 VCC_SM_14 VCC_SM_15 VCC_SM_16 VCC_SM_17 VCC_SM_18 VCC_SM_19 VCC_SM_20 VCC_SM_21 VCC_SM_22 VCC_SM_23 VCC_SM_24 VCC_SM_25 VCC_SM_26 VCC_SM_27 VCC_SM_28 VCC_SM_29 VCC_SM_30 VCC_SM_31 VCC_SM_32 VCC_SM_33 VCC_SM_34 VCC_SM_35 VCC_SM_36 2 2 POWER AU32 AU33 AU35 AV33 AW33 AW35 AY35 BA32 BA33 BA35 BB33 BC32 BC33 BC35 BD32 BD35 BE32 BE33 BE35 BF33 BF34 BG32 BG33 BG35 BH32 BH34 BH35 BJ32 BJ33 BJ34 BK32 BK33 BK34 BK35 BL33 AU30 VCC GFX NCTF (2.4A) C181 C179 C184 C0.22U6.3X50402 C0.1U10X0402 C0.22U6.3X50402 C220U2.5SP-LF 1 +1_8VDIMM U27F C206 2 VCC_13 T17 T18 T19 T21 T22 T23 T25 U15 U16 U17 U19 U20 U21 U23 U26 V16 V17 V19 V20 V21 V23 V24 Y15 Y16 Y17 Y19 Y20 Y21 Y23 Y24 Y26 Y28 Y29 AA16 AA17 AB16 AB19 AC16 AC17 AC19 AD15 AD16 AD17 AF16 AF19 AH15 AH16 AH17 AH19 AJ16 AJ17 AJ19 AK16 AK19 AL16 AL17 AL19 AL20 AL21 AL23 AM15 AM16 AM19 AM20 AM21 AM23 AP15 AP16 AP17 AP19 AP20 AP21 AP23 AP24 AR20 AR21 AR23 AR24 AR26 V26 V28 V29 Y31 VCC_AXG_NCTF_1 VCC_AXG_NCTF_2 VCC_AXG_NCTF_3 VCC_AXG_NCTF_4 VCC_AXG_NCTF_5 VCC_AXG_NCTF_6 VCC_AXG_NCTF_7 VCC_AXG_NCTF_8 VCC_AXG_NCTF_9 VCC_AXG_NCTF_10 VCC_AXG_NCTF_11 VCC_AXG_NCTF_12 VCC_AXG_NCTF_13 VCC_AXG_NCTF_14 VCC_AXG_NCTF_15 VCC_AXG_NCTF_16 VCC_AXG_NCTF_17 VCC_AXG_NCTF_18 VCC_AXG_NCTF_19 VCC_AXG_NCTF_20 VCC_AXG_NCTF_21 VCC_AXG_NCTF_22 VCC_AXG_NCTF_23 VCC_AXG_NCTF_24 VCC_AXG_NCTF_25 VCC_AXG_NCTF_26 VCC_AXG_NCTF_27 VCC_AXG_NCTF_28 VCC_AXG_NCTF_29 VCC_AXG_NCTF_30 VCC_AXG_NCTF_31 VCC_AXG_NCTF_32 VCC_AXG_NCTF_33 VCC_AXG_NCTF_34 VCC_AXG_NCTF_35 VCC_AXG_NCTF_36 VCC_AXG_NCTF_37 VCC_AXG_NCTF_38 VCC_AXG_NCTF_39 VCC_AXG_NCTF_40 VCC_AXG_NCTF_41 VCC_AXG_NCTF_42 VCC_AXG_NCTF_43 VCC_AXG_NCTF_44 VCC_AXG_NCTF_45 VCC_AXG_NCTF_46 VCC_AXG_NCTF_47 VCC_AXG_NCTF_48 VCC_AXG_NCTF_49 VCC_AXG_NCTF_50 VCC_AXG_NCTF_51 VCC_AXG_NCTF_52 VCC_AXG_NCTF_53 VCC_AXG_NCTF_54 VCC_AXG_NCTF_55 VCC_AXG_NCTF_56 VCC_AXG_NCTF_57 VCC_AXG_NCTF_58 VCC_AXG_NCTF_59 VCC_AXG_NCTF_60 VCC_AXG_NCTF_61 VCC_AXG_NCTF_62 VCC_AXG_NCTF_63 VCC_AXG_NCTF_64 VCC_AXG_NCTF_65 VCC_AXG_NCTF_66 VCC_AXG_NCTF_67 VCC_AXG_NCTF_68 VCC_AXG_NCTF_69 VCC_AXG_NCTF_70 VCC_AXG_NCTF_71 VCC_AXG_NCTF_72 VCC_AXG_NCTF_73 VCC_AXG_NCTF_74 VCC_AXG_NCTF_75 VCC_AXG_NCTF_76 VCC_AXG_NCTF_77 VCC_AXG_NCTF_78 VCC_AXG_NCTF_79 VCC_AXG_NCTF_80 VCC_AXG_NCTF_81 VCC_AXG_NCTF_82 VCC_AXG_NCTF_83 VCC SM LF R30 VCC CORE VTT VCC_1 VCC_2 VCC_3 VCC_5 VCC_4 VCC_6 VCC_7 VCC_8 VCC_9 VCC_10 VCC_11 VCC_12 + 1 U27G AT35 AT34 AH28 AC32 AC31 AK32 AJ31 AJ28 AH32 AH31 AH29 AF32 VCC SM (Ex- 1.3A) (1.2A) AT33 AT31 AK29 AK24 AK23 AJ26 AJ23 VCC_AXM_1 VCC_AXM_2 VCC_AXM_3 VCC_AXM_4 VCC_AXM_5 VCC_AXM_6 VCC_AXM_7 (540mA) 3 X_C10U6.3X50805-1 CRESTLINE_1p0 VCCSM_LF1 VCCSM_LF2 VCCSM_LF3 VCCSM_LF4 VCCSM_LF5 VCCSM_LF6 VCCSM_LF7 C214 C0.1U10X0402 C217 C0.1U10X0402 C219 C221 C215 C0.22U6.3X50402 C0.47U10X C0.22U6.3X50402 C218 C1U10X C216 C1U10X 4 MSI CORPORATION Title CRESTLINE-4 (POWER-1) CRESTLINE_1p0 Size Document Number Custom Date: A B C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 8 of 41 A B C D E VTT (850mA) +3VRUN U27H AL2 +1_25M_MPLL AM2 C392 X_C0.33U16Y +1_8VSUS_TXLVDS VCCA_HPLL VCCA_MPLL (10mA) A41 C148 +3VRUN B41 VCCA_LVDS VSSA_LVDS C1000P50X0402 (5mA) +1_25VRUN +1_25VRUN_DPLLA LG1 10U100m_0805 + 1 2 K50 K49 (40mA) C150 C0.1U10X0402 CG1 +1_25VRUN_PEGPLL U51 (100mA) +1_25VRUN AW18 AV19 AU19 AU18 AU17 2 C100U6.3POS CG11 C0.1U10X0402 +1_25VRUN_DPLLB LG2 C223 C22U6.3X50805-RH (40mA) + 1 10U100m_0805 CG10 CG12 C0.1U10X0402 AT22 AT21 AT19 AT18 AT17 AR17 AR16 +1_25VRUN L22 2 C100U6.3POS Cost down Cap C205 C0.1U10X0402 VCCA_SM_CK 200L500m_300-RH C225 C228 C222 C1U10X C1U10X C0.1U10X0402 BC29 BB29 +3VRUN_CRTDAC +1_25VRUN +1_25M_HPLL L38 C25 B25 C27 B27 B28 A28 (50mA) (120mA) 120L0.6A +1_5VRUN 3 C422 C416 C22U6.3X50805-RH C0.1U10X0402 (60mA) +1_25M_MPLL L36 M32 L29 C154 C155 +1_5VRUN_QDAC C0.1U10X0402 C0.022U16X0402-RH (150mA) N28 +1_25VRUN 120L0.6A (250mA) C421 C418 C22U6.3X50805-RH C0.1U10X0402 (100mA) C417 C0.1U10X0402 U48 +1_8VDIMM J41 H42 C400 C0.1U10X0402 +1_5VRUN AN2 +1_25VRUN_PEGPLL +1_5VRUN_QDAC (150mA) C156 C0.1U10X0402 L21 VTT VCCA_DPLLB VCCA_PEG_BG VSSA_PEG_BG VCCA_PEG_PLL VCCA_SM_1 VCCA_SM_2 VCCA_SM_3 VCCA_SM_4 VCCA_SM_5 VCCA_SM_7 VCCA_SM_8 VCCA_SM_9 VCCA_SM_10 VCCA_SM_11 VCCA_SM_NCTF_1 VCCA_SM_NCTF_2 VCCA_SM_CK_1 VCCA_SM_CK_2 VCCA_TVA_DAC_1 VCCA_TVA_DAC_2 VCCA_TVB_DAC_1 VCCA_TVB_DAC_2 VCCA_TVC_DAC_1 VCCA_TVC_DAC_2 VCCD_CRT VCCD_TVDAC VCCD_QDAC VCCD_HPLL VCCD_PEG_PLL VCCD_LVDS_1 VCCD_LVDS_2 VTT_1 VTT_2 VTT_3 VTT_4 VTT_5 VTT_6 VTT_7 VTT_8 VTT_9 VTT_10 VTT_11 VTT_12 VTT_13 VTT_14 VTT_15 VTT_16 VTT_17 VTT_18 VTT_19 VTT_20 VTT_21 VTT_22 VCC_AXD_1 VCC_AXD_2 VCC_AXD_3 VCC_AXD_4 VCC_AXD_5 VCC_AXD_6 VCC_AXD_NCTF POWER AXF +1_25M_HPLL VCC_AXF_1 VCC_AXF_2 VCC_AXF_3 VCC_DMI U13 U12 U11 U9 U8 U7 U5 U3 U2 U1 T13 T11 T10 T9 T7 T6 T5 T3 T2 R3 R2 R1 AT23 AU28 AU24 AT29 AT25 AT30 C169 C4.7U6.3X5-1 C180 C4.7U6.3X5-1 VCC_TX_LVDS C326 C157 C0.1U10X0402 C0.47U10X C0.1U10X0402 +1_25VRUN C199 C1U10X +1_25VRUN C200 C1U10X (200mA) +1_25VRUN 2 AR29 B23 B21 A21 C193 C0.1U10X0402 (350mA) +1_8VSUS_SM_CLK +1_8VDIMM L23 (100mA) AJ50 C431 BK24 BK23 BJ24 BJ23 1U500m_0805-RH C233 C0.1U10X0402 C10U6.3X50805-1 +1_8VSUS_TXLVDS +1_8VDIMM L20 (100mA) A43 +3VRUN C398 VCC_HV_1 VCC_HV_2 C340 1 (200mA) VCC_SM_CK_1 VCC_SM_CK_2 VCC_SM_CK_3 VCC_SM_CK_4 HV H49 C388 X_C0.1U10X0402 PEG X_APL5151-33BC-TRL_SOT23-5-LF C386 X_C10U10Y0805 VCCA_DPLLA C40 B40 C0.1U10X0402 C149 C147 C1000P50X0402 (100mA) 1U500m_0805-RH C10U6.3X50805-1 VTT VCC_PEG VCC_PEG_1 VCC_PEG_2 VCC_PEG_3 VCC_PEG_4 VCC_PEG_5 AD51 W50 W51 V49 V50 L35 3 (1.2A) C408 C405 91N1.5_1210-RH C22U6.3X50805-RH C0.1U10X0402 (250mA) VCC_RXR_DMI_1 VCC_RXR_DMI_2 VTTLF 4 BP SHDN# B49 AXD 3 X_180L1.5A GND VSSA_DAC_BG SM CK X_C1U10X C385 C389 C387 +1_25VRUN_DPLLA C10U6.3X50805-1 C0.022U16X0402-RH C0.1U10X0402 +1_25VRUN_DPLLB APL_P5 DMI 2 5 VOUT VCCA_DAC_BG PLL C390 L33 VIN APL_P4 1 B32 A LVDS 180L1.5A U25 A PEG A30 +5VRUN CRT L32 A SM +3VRUN_CRTDAC VCCA_CRT_DAC_1 VCCA_CRT_DAC_2 A CK +3VRUN 1 A33 B33 TV (80mA) C152 C0.1U10X0402 VCCSYNC D TV/CRT J32 LVDS (10mA) VTTLF1 VTTLF2 VTTLF3 AH50 AH51 A7 F2 AH1 VTTLF1 VTTLF2 VTTLF3 C411 C0.47U10X C396 C0.47U10X C391 C0.47U10X CRESTLINE_1p0 180L1.5A C153 C0.1U10X0402 C158 C167 C0.1U10X0402 C0.022U16X0402-RH 4 4 +1_25VRUN +1_25VRUN_PEGPLL Place close to NB VTT +3VRUN L34 A 220L2_50 C399 C401 C0.1U10X0402 D3 C MSI CORPORATION VCCGFOLLOW R210 X_S-RB551V-30_SOD323 Title X_10R0402 CRESTLINE-5 (POWER-2) C10U6.3X50805-1 Size Document Number Cust om Date: A [email protected] GRATIS - FOR FREE B C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 9 of 41 A B C D E U27I U27J A13 A15 A17 A24 AA21 AA24 AA29 AB20 AB23 AB26 AB28 AB31 AC10 AC13 AC3 AC39 AC43 AC47 AD1 AD21 AD26 AD29 AD3 AD41 AD45 AD49 AD5 AD50 AD8 AE10 AE14 AE6 AF20 AF23 AF24 AF31 AG2 AG38 AG43 AG47 AG50 AH3 AH40 AH41 AH7 AH9 AJ11 AJ13 AJ21 AJ24 AJ29 AJ32 AJ43 AJ45 AJ49 AK20 AK21 AK26 AK28 AK31 AK51 AL1 AM11 AM13 AM3 AM4 AM41 AM45 AN1 AN38 AN39 AN43 AN5 AN7 AP4 AP48 AP50 AR11 AR2 AR39 AR44 AR47 AR7 AT10 AT14 AT41 AT49 AU1 AU23 AU29 AU3 AU36 AU49 AU51 AV39 AV48 AW1 AW12 AW16 1 2 3 4 VSS_1 VSS_2 VSS_3 VSS_4 VSS_5 VSS_6 VSS_7 VSS_8 VSS_9 VSS_10 VSS_11 VSS_12 VSS_13 VSS_14 VSS_15 VSS_16 VSS_17 VSS_18 VSS_19 VSS_20 VSS_21 VSS_22 VSS_23 VSS_24 VSS_25 VSS_26 VSS_27 VSS_28 VSS_29 VSS_30 VSS_31 VSS_32 VSS_33 VSS_34 VSS_35 VSS_36 VSS_37 VSS_38 VSS_39 VSS_40 VSS_41 VSS_42 VSS_43 VSS_44 VSS_45 VSS_46 VSS_47 VSS_48 VSS_49 VSS_50 VSS_51 VSS_52 VSS_53 VSS_54 VSS_55 VSS_56 VSS_57 VSS_58 VSS_59 VSS_60 VSS_61 VSS_62 VSS_63 VSS_64 VSS_65 VSS_66 VSS_67 VSS_68 VSS_69 VSS_70 VSS_71 VSS_72 VSS_73 VSS_74 VSS_75 VSS_76 VSS_77 VSS_78 VSS_79 VSS_80 VSS_81 VSS_82 VSS_83 VSS_84 VSS_85 VSS_86 VSS_87 VSS_88 VSS_89 VSS_90 VSS_91 VSS_92 VSS_93 VSS_94 VSS_95 VSS_96 VSS_97 VSS_98 VSS_99 VSS_100 VSS_101 VSS_102 VSS_103 VSS_104 VSS_105 VSS_106 VSS_107 VSS_108 VSS_109 VSS_110 VSS_111 VSS_112 VSS_113 VSS_114 VSS_115 VSS_116 VSS_117 VSS_118 VSS_119 VSS_120 VSS_121 VSS_122 VSS_123 VSS_124 VSS_125 VSS_126 VSS_127 VSS_128 VSS_129 VSS_130 VSS_131 VSS_132 VSS_133 VSS_134 VSS_135 VSS_136 VSS_137 VSS_138 VSS_139 VSS_140 VSS_141 VSS_142 VSS_143 VSS_144 VSS_145 VSS_146 VSS_147 VSS_148 VSS_149 VSS_150 VSS_151 VSS_152 VSS_153 VSS_154 VSS_155 VSS_156 VSS_157 VSS_158 VSS_159 VSS_160 VSS_161 VSS_162 VSS_163 VSS_164 VSS_165 VSS_166 VSS_167 VSS_168 VSS_169 VSS_170 VSS_171 VSS_172 VSS_173 VSS_174 VSS_175 VSS_176 VSS_177 VSS_178 VSS_179 VSS_180 VSS_181 VSS_182 VSS_183 VSS_184 VSS_185 VSS_186 VSS_187 VSS_188 VSS_189 VSS_190 VSS_191 VSS_192 VSS_193 VSS_194 VSS_195 VSS_196 VSS_197 VSS_198 VSS AW24 AW29 AW32 AW5 AW7 AY10 AY24 AY37 AY42 AY43 AY45 AY47 AY50 B10 B20 B24 B29 B30 B35 B38 B43 B46 B5 B8 BA1 BA17 BA18 BA2 BA24 BB12 BB25 BB40 BB44 BB49 BB8 BC16 BC24 BC25 BC36 BC40 BC51 BD13 BD2 BD28 BD45 BD48 BD5 BE1 BE19 BE23 BE30 BE42 BE51 BE8 BF12 BF16 BF36 BG19 BG2 BG24 BG29 BG39 BG48 BG5 BG51 BH17 BH30 BH44 BH46 BH8 BJ11 BJ13 BJ38 BJ4 BJ42 BJ46 BK15 BK17 BK25 BK29 BK36 BK40 BK44 BK6 BK8 BL11 BL13 BL19 BL22 BL37 BL47 C12 C16 C19 C28 C29 C33 C36 C41 C46 C50 C7 D13 D24 D3 D32 D39 D45 D49 E10 E16 E24 E28 E32 E47 F19 F36 F4 F40 F50 G1 G13 G16 G19 G24 G28 G29 G33 G42 G45 G48 G8 H24 H28 H4 H45 J11 J16 J2 J24 J28 J33 J35 J39 K12 K47 K8 L1 L17 L20 L24 L28 L3 L33 L49 M28 M42 M46 M49 M5 M50 M9 N11 N14 N17 N29 N32 N36 N39 N44 N49 N7 P19 P2 P23 P3 P50 R49 T39 T43 T47 U41 U45 U50 V2 V3 VSS_199 VSS_200 VSS_201 VSS_202 VSS_203 VSS_204 VSS_205 VSS_206 VSS_207 VSS_208 VSS_209 VSS_210 VSS_211 VSS_212 VSS_213 VSS_214 VSS_215 VSS_216 VSS_217 VSS_218 VSS_219 VSS_220 VSS_221 VSS_222 VSS_223 VSS_224 VSS_225 VSS_226 VSS_227 VSS_228 VSS_229 VSS_230 VSS_231 VSS_232 VSS_233 VSS_234 VSS_235 VSS_236 VSS_237 VSS_238 VSS_239 VSS_240 VSS_241 VSS_242 VSS_243 VSS_287 VSS_288 VSS_289 VSS_290 VSS_291 VSS_292 VSS_293 VSS_294 VSS_295 VSS_296 VSS_297 VSS_298 VSS_299 VSS_300 VSS_301 VSS_302 VSS_303 VSS_304 VSS_305 VSS_306 VSS_307 VSS_308 VSS_309 VSS_310 VSS_311 VSS_312 VSS_313 W11 W39 W43 W47 W5 W7 Y13 Y2 Y41 Y45 Y49 Y5 Y50 Y11 P29 T29 T31 T33 R28 1 AA32 AB32 AD32 AF28 AF29 AT27 AV25 H50 2 VSS VSS_245 VSS_246 VSS_247 VSS_248 VSS_249 VSS_250 VSS_251 VSS_252 VSS_253 VSS_254 VSS_255 VSS_256 VSS_257 VSS_258 VSS_259 VSS_260 VSS_261 VSS_262 VSS_263 VSS_264 VSS_265 VSS_266 VSS_267 VSS_268 VSS_269 VSS_270 VSS_271 VSS_272 VSS_273 VSS_274 VSS_275 VSS_276 VSS_277 VSS_278 VSS_279 VSS_280 VSS_281 VSS_282 VSS_283 VSS_284 VSS_285 VSS_286 3 CRESTLINE_1p0 4 MSI CORPORATION Title CRESTLINE_1p0 CRESTLINE-6 (VSS) Size Document Number Custom Date: A B C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 10 E of 41 A 7 B C DIMM1A M_A_DQ[63:0] M _ A _ DQ0 M _ A _ DQ1 M _ A _ DQ2 M _ A _ DQ3 M _ A _ DQ4 M _ A _ DQ5 M _ A _ DQ6 M _ A _ DQ7 M _ A _ DQ8 M _ A _ DQ9 M_A_DQ10 M_A_DQ11 M_A_DQ12 M_A_DQ13 M_A_DQ14 M_A_DQ15 M_A_DQ16 M_A_DQ17 M_A_DQ18 M_A_DQ19 M_A_DQ20 M_A_DQ21 M_A_DQ22 M_A_DQ23 M_A_DQ24 M_A_DQ25 M_A_DQ26 M_A_DQ27 M_A_DQ28 M_A_DQ29 M_A_DQ30 M_A_DQ31 M_A_DQ32 M_A_DQ33 M_A_DQ34 M_A_DQ35 M_A_DQ36 M_A_DQ37 M_A_DQ38 M_A_DQ39 M_A_DQ40 M_A_DQ41 M_A_DQ42 M_A_DQ43 M_A_DQ44 M_A_DQ45 M_A_DQ46 M_A_DQ47 M_A_DQ48 M_A_DQ49 M_A_DQ50 M_A_DQ51 M_A_DQ52 M_A_DQ53 M_A_DQ54 M_A_DQ55 M_A_DQ56 M_A_DQ57 M_A_DQ58 M_A_DQ59 M_A_DQ60 M_A_DQ61 M_A_DQ62 M_A_DQ63 1 2 3 5 7 17 19 4 6 14 16 23 25 35 37 20 22 36 38 43 45 55 57 44 46 56 58 61 63 73 75 62 64 74 76 123 125 135 137 124 126 134 136 141 143 151 153 140 142 152 154 157 159 173 175 158 160 174 176 179 181 189 191 180 182 192 194 DQ0 DQ1 DQ2 DQ3 DQ4 DQ5 DQ6 DQ7 DQ8 DQ9 DQ10 DQ11 DQ12 DQ13 DQ14 DQ15 DQ16 DQ17 DQ18 DQ19 DQ20 DQ21 DQ22 DQ23 DQ24 DQ25 DQ26 DQ27 DQ28 DQ29 DQ30 DQ31 DQ32 DQ33 DQ34 DQ35 DQ36 DQ37 DQ38 DQ39 DQ40 DQ41 DQ42 DQ43 DQ44 DQ45 DQ46 DQ47 DQ48 DQ49 DQ50 DQ51 DQ52 DQ53 DQ54 DQ55 DQ56 DQ57 DQ58 DQ59 DQ60 DQ61 DQ62 DQ63 M_A_A[13:0] A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10/AP A11 A12 A13 A14 A15 A16_BA2 BA0 BA1 S0# S1# CK0 CK0# CK1 CK1# CKE0 CKE1 CAS# RAS# WE# SA0 SA1 SCL SDA ODT0 ODT1 DM0 DM1 DM2 DM3 DM4 DM5 DM6 DM7 DQS0 DQS1 DQS2 DQS3 DQS4 DQS5 DQS6 DQS7 DQS#0 DQS#1 DQS#2 DQS#3 DQS#4 DQS#5 DQS#6 DQS#7 102 101 100 99 98 97 94 92 93 91 105 90 89 116 86 84 85 107 106 110 115 30 32 164 166 79 80 113 108 109 198 200 197 195 M _ A _A0 M _ A _A1 M _ A _A2 M _ A _A3 M _ A _A4 M _ A _A5 M _ A _A6 M _ A _A7 M _ A _A8 M _ A _A9 M _ A _ A10 M _ A _ A11 M _ A _ A12 M _ A _ A13 M _ A _ A14 +1_8VDIMM 7,13 10 26 52 67 130 147 170 185 M _ A _DM0 M _ A _DM1 M _ A _DM2 M _ A _DM3 M _ A _DM4 M _ A _DM5 M _ A _DM6 M _ A _DM7 13 31 51 70 131 148 169 188 11 29 49 68 129 146 167 186 M _ A _ DQS0 M _ A _ DQS1 M _ A _ DQS2 M _ A _ DQS3 M _ A _ DQS4 M _ A _ DQS5 M _ A _ DQS6 M _ A _ DQS7 M _ A _ DQS#0 M _ A _ DQS#1 M _ A _ DQS#2 M _ A _ DQS#3 M _ A _ DQS#4 M _ A _ DQS#5 M _ A _ DQS#6 M _ A _ DQS#7 112 111 117 96 95 118 81 82 87 103 88 104 +3VRUN M _ A _A14 C244 C2.2U6.3Y 6,13 M _ A _BS0 7,13 M _ A _BS1 7,13 M_CS#0 6,13 M_CS#1 6,13 M_CLK_DDR0 6 M_CLK_DDR# 0 6 M_CLK_DDR1 6 M_CLK_DDR# 1 6 M_CKE0 6,13 M_CKE1 6,13 M _ A _ CAS# 7,13 M _ A _ RAS# 7,13 M _ A _ WE# 7,13 M _ O DT0 M _ O DT1 M_A_DM[7:0] C246 C0.1U10X0402 199 83 120 50 69 163 203 204 1 7,13 6 R236 P M _EXTTS#0 X _ 0 R0402 SMDDR_VREF SMDDR_VREF Trace : 10 mils C252 C2.2U6.3Y C245 C0.1U10X0402 R238 6,13 6,13 7 as close as SO-DIMM 10KR1%0402 SMDDR_VREF SA_SA0 R234 10KR0402 SA_SA1 R235 10KR0402 201 202 47 133 183 77 12 48 184 78 71 72 121 122 196 193 8 +1_8VDIMM S M B _ CLK_M2 12,15,19,36 S M B _ DATA_M2 12,15,19,36 114 119 E DIMM1B M _ A _BS2 SA_SA0 SA_SA1 D R237 C254 10KR1%0402 C0.1U10X0402 VDD1 VDD2 VDD3 VDD4 VDD5 VDD6 VDD7 VDD8 VDD9 VDD10 VDD11 VDD12 VDDSPD NC1 NC2 NC3 NC4 NCTEST NC5 NC6 VREF GND0 GND1 VSS1 VSS2 VSS3 VSS4 VSS5 VSS6 VSS7 VSS8 VSS9 VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 18 24 41 53 42 54 59 65 60 66 127 139 128 145 165 171 172 177 187 178 190 9 21 33 155 34 132 144 156 168 2 3 15 27 39 149 161 28 40 138 150 162 VSS16 VSS17 VSS18 VSS19 VSS20 VSS21 VSS22 VSS23 VSS24 VSS25 VSS26 VSS27 VSS28 VSS29 VSS30 VSS31 VSS32 VSS33 VSS34 VSS35 VSS36 VSS37 VSS38 VSS39 VSS40 VSS41 VSS42 VSS43 VSS44 VSS45 VSS46 VSS47 VSS48 VSS49 VSS50 VSS51 VSS52 VSS53 VSS54 VSS55 VSS56 VSS57 1 2 DIMM-200S_black-1 M_A_DQS[7:0] 7 Layout note: Place capacitors between and near DDR connector if possible. 3 +1_8VDIMM M_A_DQS#[7:0] 7 C460 C251 C439 C247 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 DIMM-200S_black-1 PC133 1 +1_8VDIMM + C231 C2.2U6.3Y C234 C2.2U6.3Y C463 C2.2U6.3Y C438 C2.2U6.3Y C248 C2.2U6.3Y 2 C220U2.5SP-L F 4 4 MSI CORPORATION T i tle DDR2 SODIMM 0 Size Document Number Custom Date: A [email protected] GRATIS - FOR FREE B C D Rev MS-1221 Wednesday, September 06, 2006 0B Sheet 11 E of 41 A 7 B C DIMMB1A M_B_DQ[63:0] M_B_DQ0 M_B_DQ1 M_B_DQ2 M_B_DQ3 M_B_DQ4 M_B_DQ5 M_B_DQ6 M_B_DQ7 M_B_DQ8 M_B_DQ9 M_B_DQ10 M_B_DQ11 M_B_DQ12 M_B_DQ13 M_B_DQ14 M_B_DQ15 M_B_DQ16 M_B_DQ17 M_B_DQ18 M_B_DQ19 M_B_DQ20 M_B_DQ21 M_B_DQ22 M_B_DQ23 M_B_DQ24 M_B_DQ25 M_B_DQ26 M_B_DQ27 M_B_DQ28 M_B_DQ29 M_B_DQ30 M_B_DQ31 M_B_DQ32 M_B_DQ33 M_B_DQ34 M_B_DQ35 M_B_DQ36 M_B_DQ37 M_B_DQ38 M_B_DQ39 M_B_DQ40 M_B_DQ41 M_B_DQ42 M_B_DQ43 M_B_DQ44 M_B_DQ45 M_B_DQ46 M_B_DQ47 M_B_DQ48 M_B_DQ49 M_B_DQ50 M_B_DQ51 M_B_DQ52 M_B_DQ53 M_B_DQ54 M_B_DQ55 M_B_DQ56 M_B_DQ57 M_B_DQ58 M_B_DQ59 M_B_DQ60 M_B_DQ61 M_B_DQ62 M_B_DQ63 1 2 3 5 7 17 19 4 6 14 16 23 25 35 37 20 22 36 38 43 45 55 57 44 46 56 58 61 63 73 75 62 64 74 76 123 125 135 137 124 126 134 136 141 143 151 153 140 142 152 154 157 159 173 175 158 160 174 176 179 181 189 191 180 182 192 194 DQ0 DQ1 DQ2 DQ3 DQ4 DQ5 DQ6 DQ7 DQ8 DQ9 DQ10 DQ11 DQ12 DQ13 DQ14 DQ15 DQ16 DQ17 DQ18 DQ19 DQ20 DQ21 DQ22 DQ23 DQ24 DQ25 DQ26 DQ27 DQ28 DQ29 DQ30 DQ31 DQ32 DQ33 DQ34 DQ35 DQ36 DQ37 DQ38 DQ39 DQ40 DQ41 DQ42 DQ43 DQ44 DQ45 DQ46 DQ47 DQ48 DQ49 DQ50 DQ51 DQ52 DQ53 DQ54 DQ55 DQ56 DQ57 DQ58 DQ59 DQ60 DQ61 DQ62 DQ63 M_B_A[13:0] A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10/AP A11 A12 A13 A14 A15 A16_BA2 BA0 BA1 S0# S1# CK0 CK0# CK1 CK1# CKE0 CKE1 CAS# RAS# WE# SA0 SA1 SCL SDA ODT0 ODT1 DM0 DM1 DM2 DM3 DM4 DM5 DM6 DM7 DQS0 DQS1 DQS2 DQS3 DQS4 DQS5 DQS6 DQS7 DQS#0 DQS#1 DQS#2 DQS#3 DQS#4 DQS#5 DQS#6 DQS#7 M_B_A0 M_B_A1 M_B_A2 M_B_A3 M_B_A4 M_B_A5 M_B_A6 M_B_A7 M_B_A8 M_B_A9 M_B_A10 M_B_A11 M_B_A12 M_B_A13 M_B_A14 102 101 100 99 98 97 94 92 93 91 105 90 89 116 86 84 85 107 106 110 115 30 32 164 166 79 80 113 108 109 198 200 197 195 SB_SA0 SB_SA1 10 26 52 67 130 147 170 185 M_B_DM0 M_B_DM1 M_B_DM2 M_B_DM3 M_B_DM4 M_B_DM5 M_B_DM6 M_B_DM7 13 31 51 70 131 148 169 188 11 29 49 68 129 146 167 186 M_B_DQS0 M_B_DQS1 M_B_DQS2 M_B_DQS3 M_B_DQS4 M_B_DQS5 M_B_DQS6 M_B_DQS7 M_B_DQS#0 M_B_DQS#1 M_B_DQS#2 M_B_DQS#3 M_B_DQS#4 M_B_DQS#5 M_B_DQS#6 M_B_DQS#7 E 7,13 +1_8VDIMM DIMMB1B 112 111 117 96 95 118 81 82 87 103 88 104 +3VRUN M_B_A14 6,13 M_B_BS2 7,13 C253 C2.2U6.3Y M_B_BS0 7,13 M_B_BS1 7,13 M_CS#2 6,13 M_CS#3 6,13 M_CLK_DDR3 6 M_CLK_DDR#3 6 M_CLK_DDR4 6 M_CLK_DDR#4 6 M_CKE3 6,13 M_CKE4 6,13 M_B_CAS# 7,13 M_B_RAS# 7,13 M_B_WE# 7,13 6 M_ODT2 M_ODT3 M_B_DM[7:0] C443 C0.1U10X0402 R241 PM_EXTTS#1 X_0R0402 SMDDR_VREF SMDDR_VREF Trace : 10 mils +3VRUN SMB_CLK_M2 11,15,19,36 SMB_DATA_M2 11,15,19,36 114 119 D SB_SA1 R394 10KR0402 SB_SA0 R395 10KR0402 C241 C2.2U6.3Y C243 C0.1U10X0402 199 83 120 50 69 163 203 204 1 201 202 47 133 183 77 12 48 184 78 71 72 121 122 196 193 8 6,13 6,13 7 Layout note: Place capacitors between and near DDR connector if possible. +1_8VDIMM VSS16 VSS17 VSS18 VSS19 VSS20 VSS21 VSS22 VSS23 VSS24 VSS25 VSS26 VSS27 VSS28 VSS29 VSS30 VSS31 VSS32 VSS33 VSS34 VSS35 VSS36 VSS37 VSS38 VSS39 VSS40 VSS41 VSS42 VSS43 VSS44 VSS45 VSS46 VSS47 VSS48 VSS49 VSS50 VSS51 VSS52 VSS53 VSS54 VSS55 VSS56 VSS57 VDD1 VDD2 VDD3 VDD4 VDD5 VDD6 VDD7 VDD8 VDD9 VDD10 VDD11 VDD12 VDDSPD NC1 NC2 NC3 NC4 NCTEST NC5 NC6 VREF GND0 GND1 VSS1 VSS2 VSS3 VSS4 VSS5 VSS6 VSS7 VSS8 VSS9 VSS10 VSS11 VSS12 VSS13 VSS14 VSS15 1 18 24 41 53 42 54 59 65 60 66 127 139 128 145 165 171 172 177 187 178 190 9 21 33 155 34 132 144 156 168 2 3 15 27 39 149 161 28 40 138 150 162 2 3 DIMM-200S_black M_B_DQS[7:0] 7 C451 C250 C448 C440 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 M_B_DQS#[7:0] 7 +1_8VDIMM C449 C2.2U6.3Y C461 C2.2U6.3Y C437 C2.2U6.3Y C249 C2.2U6.3Y C450 C2.2U6.3Y DIMM-200S_black 4 4 MSI CORPORATION Title DDR2 SODIMM 1 Size Document Number Custom Date: A B C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 12 of 41 A B M_A_A[13:0] M_B_A[13:0] C M_A_A[13:0] 7,11 M_B_A[13:0] 7,12 D E SMDDR_VTERM RNT5 1 SMDDR_VTERM RNT2 7,11 2 6,11 7,11 M_A_BS1 M_CKE0 M_A_BS2 RNT11 M_A_A8 M_A_A3 M_A_A5 M_A_A10 1 3 5 7 M_A_A2 M_A_A4 M_A_A0 M_A_BS1 8P4R-56R0402 RNT4 1 2 3 4 5 6 7 8 8P4R-56R0402 RNT8 1 2 M_B_A10 M_B_A1 3 4 5 6 M_B_A3 M_B_A5 7 8 M_CKE0 M_A_A12 M_A_BS2 M_A_A9 8P4R-56R0402 RNT1 1 2 3 4 5 6 7 8 8P4R-56R0402 RNT7 M_B_A9 1 2 M_B_A8 3 4 5 6 M_B_BS2 7 8 M_B_A12 2 4 6 8 1 3 5 7 8P4R-56R0402 M_B_A2 M_B_A4 M_B_A0 M_B_BS1 2 4 6 8 M_B_BS1 7,12 6,11 7,11 M_CS#0 M_A_RAS# 6,11 M_ODT0 7,11 7,11 6,11 6,11 6,12 M_A_BS0 M_A_CAS# M_CS#1 M_ODT1 M_CKE4 RNT12 M_CS#0 M_A_RAS# M_A_A13 M_ODT0 1 3 5 7 M_A_BS0 M_A_CAS# M_CS#1 M_ODT1 8P4R-56R0402 RNT3 1 2 3 4 5 6 7 8 8P4R-56R0402 RNT6 1 2 M_A_A6 M_A_A7 3 4 M_A_A11 5 6 M_CKE1 7 8 M_B_A6 M_B_A11 M_B_A7 M_CKE4 8P4R-56R0402 RNT10 1 2 3 4 5 6 7 8 8P4R-56R0402 RNT9 M_CS#3 1 2 M_B_CAS# 3 4 5 6 M_B_WE# M_B_BS0 7 8 8P4R-56R0402 8P4R-56R0402 2 4 6 8 1 3 5 7 2 4 6 8 M_CS#2 M_B_RAS# M_B_A13 M_ODT2 M_CS#2 M_B_RAS# 6,12 7,12 M_ODT2 6,12 M_CKE1 6,11 M_CS#3 M_B_CAS# M_B_WE# M_B_BS0 6,12 7,12 7,12 7,12 1 2 M_B_BS2 7,12 7,11 M_A_WE# M_A_WE# RT7 56R0402 R239 56R0402 M_CKE3 M_A_A1 R232 56R0402 R240 56R0402 M_ODT3 M_A_A14 R233 56R0402 R242 56R0402 M_B_A14 8P4R-56R0402 6,11 M_A_A14 SMDDR_VTERM M_CKE3 6,12 M_ODT3 6,12 M_B_A14 6,12 SMDDR_VTERM CT31 CT39 CT41 CT38 CT19 CT24 CT25 CT32 CT30 CT27 CT33 CT20 CT21 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 3 3 SMDDR_VTERM SMDDR_VTERM CT34 CT40 CT26 CT37 CT22 CT28 CT16 CT18 CT35 CT29 CT23 CT17 CT36 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 Layout note: Place one cap close to every 2 pullup resistors terminated to +SMDDR_VTERN. SMDDR_VTERM 4 C237 C240 C10U6.3X50805-1 C10U6.3X50805-1 Title DDR2 TREMINATION Size Document Number Custom Date: A [email protected] GRATIS - FOR FREE B 4 MSI CORPORATION C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 13 E of 41 5 4 3 2 1 +1_8VDIMM CLOSE TO CONNECTOR TX2+ R211 SiI1390 TMDS TX C192 C0.1U10X0402 300R1%0402 C134 C4.7U6.3X5-1 QP1 1 2 5 6 TX2TX1+ LAYOUT RULES: C185 C0.1U10X0402 300R1%0402 TX1TX0+ Avoid placing GND Copper or traces adjacent to TMD S Trace 31 C172 C0.1U10X0402 300R1%0402 TX0- 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 TXC+ R200 +5VRUN C159 C0.1U10X0402 300R1%0402 TXC+5VRUN HTP_TO_BUF R201 R196 2.2KR0402 2.2KR0402 HTP_FR_uC 392R1% SCLDDC SDADDC C0.1U10X0402 31 X_1KR0402 1 7 6 18 SDVO_RST# 6 SDVO_CTRLCLK 6 SDVO_CTRLDATA A1 8 PVCC1 PGND1 RESET# SDSCL SDSDA PVCC2 PGND2 LSCL/ASEL1/R2 LSDA/ASEL0/R1 LINT#/R0 WS/SYNC/R4 SPDIF/SDI/SD2/R3 TP_GND GND GND SGND SGND SPVCC SPGND C1000P50X0402 C0.1U10X0402 +1_8VRUN +3VRUN 17 16 C104 C115 C0.1U10X0402 C1U16Y L7 50 56 C57 C66 C53 C0.1U10X0402 L12 C1000P50X0402 C1U16Y +1_8VRUN SVCC L13 180L1.5A C76 65 41 45 53 59 62 C77 C86 MICROCONTROLLER +3VRUN 180L1.5A 63 C101 C98 C474 C12P50N0402 +3VRUN C1000P50X0402 R130 22R0402 11.0592MHz U31 LSDA LSCL U29 +3VRUN R86 22R0402 HDMI_HDA_SYNC 17 LOW 0x70 0X70=SDVO HIGH 0x72 0X74=SDVO HDA_SDIN2 1 15 14 R396 17 4 4 C50 X_C10P50N0402 300R1%0402 +3VRUN +3VRUN HDMI_HDA_SDOUT 17 HDMI_HDA_RST# 17 C477 X_C0.1U10X0402 R404 4.7KR0402 5 HTP_TO_BUF 2 HTP_TO_ uC HTP_FR_uC 4 2.5VSDA LVC1G125DBVR_SOT23-5-RH 2 316R1% C125 1KR1%0402 C0.1U10X0402 C114 R132 C1U16Y 5.6KR0402 TX_DDC_SCL TX_DDC_SDA LSCL LSDA +3VRUN 3 R163 X1 X2 PSEN- ALE/PROG- RST EA-/VPP 26 B 27 29 37 36 35 34 33 32 31 30 P3.0/RxD P0.0/A0 P3.1/TxD P0.1/A1 P0.2/A2 P3.2/INT0P0.3/A3 P3.3/INT1P3.4/T0 P0.4/A4 P3.5/T1 P0.5/A5 P0.6/A6 P3.6/WRP3.7/RDP0.7/A7 5 7 8 9 10 11 12 13 1390INT # R401 0R0402 LINT# 1 U33 +3VRUN R167 C10U10Y0805 R400 LVC1G125DBVR_SOT23-5-RH 0R 3 HDMI_HDA_BIT_CLK 17 I2C Address Sele ct (LA2) C486 C473 C12P50N0402 2 LOCAL I2C C0.1U10X0402 SDVO_RST# 1KR0402 (A1) C478 X_C0.1U10X0402 LINT# R77 SDVO I2C X_CMC-L02-9008014-T34 Y5 X_AT24C02B-10TU-1.8-RH STATE TX2+ X_CMC-L02-9008014-T34 SPVCC 5 8 7 6 5 L11 TX1+ C88 C1000P50X0402 C1000P50X0402 C0.1U10X0402 C0.1U10X0402 L16 TX2- 180L1.5A +3VRUN X_1KR0402 A0 VCC A1 WP A2 SCL VSSSDA X_CMC-L02-9008014-T34 +3VRUN PVCC2_1390 32 33 U15 1 2 3 4 X_CMC-L02-9008014-T34 180L1.5A TX1- C0.1U10X0402 ASDI C110 TX0+ +3VRUN R88 X_C0.1U10X0402 C L14 TXC- PVCC1_1390 C462 B L15 +3VRUN L17 2 C0.1U10X0402 34 64 TX01 180L1.5A 4 C83 3 18 24 30 C94 TXC+ 4 3 2 MCLK/BCLK TEST 43 44 40 42 TEST SDAROM SCLROM SD1/RST#/R8 SD0/SDO/R7 13 14 SCK/LA2 SD_PROM SC_PROM SVCC0 SVCC1 SDADDC SCLDDC 35 36 For 1390 : FLASH EEPROM WITH ADD2-N-1390_00.SPD +3VRUN 12 11 37 1KR0402 AVCC_1390 C70 21 27 A1 R140 SDADDC SCLDDC CLOSE TO CONNECTOR CLOSE TO CONNECTOR +3VRUN L6 1 R135 1KR1%0402 5 10 1 BAV99LT1_SOT23 38 R90 EXT_RES 2 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C10U10Y0805 X_C1000P50X0402 C0.1U10X0402 CONN-STAR TAKE19_black-RH H D MI_SMT_TypeII_NP_H6_18 N5I-19M0090-A10 D2 VCC +3VRUN 49 +5VRUN C69 2 E X T _RES OTPVCC OVCC SDC+ SDC- C112 4 20 19 AGND AGND AGND C71 3 60 61 SiI1390 SDB+ SDB- C C67 21 1 6 SDVOB_Clk+ 6 SDVOB_Clk- AVCC0 AVCC1 C64 C10U10Y0805 23 22 2 57 58 SDG+ SDG- 15KR0402 C65 C106 1 6 SDVOB_Blue+ 6 SDVOB_Blue- GND GND 9 15 48 38 +3VRUN 2 54 55 SDR+ SDR- R198 D C10U10Y0805 4 6 SDVOB_Green+ 6 SDVOB_Green- VCC0 VCC1 VCC2 VCC3 1KR0402 +1_8VRUN C120 3 51 52 R197 HTPLG SHELL1 D2+ D2 Shield D2D1+ D1 Shield D1D0+ D0 Shield D0CK+ CK Shield CKCE Remote NC DDC CLK DDC DATA GND G23 +5V G22 HP DET SHELL2 4 6 SDVOB_Red+ 6 SDVOB_Red- SDI+ SDI- X_0R0402 39 20 3 46 47 F3 +5VRUN 3 C62 C0.1U10X0402 R87 EXT_SWING SDVO_INT- TXC+ TXC- TX2+ TX2- SDVO_INT + 23 22 U11 TX0+ TX0- C63 26 25 F-SMD1206P050TF-15-RH NB_RXN1 TX1+ TX1- 6 EXT_SWING R80 NB_RXP1 29 28 6 N-SI3456BDV-T1-E3_TSOP 6-LF CON14 R206 Put these 4 resistors and 4 capacitors as close as possible to the TMDS output pins of the SiI1390 380mA 3 RUND 4 Route traces with 100 Ohm Differential Impedance D +1_8VRUN R208 SDVO_CTRLCLK R399 X_0R0402 P4.2/INT3# P4.3/INT2# P4.0 P4.1 16 SCLDDC 2.5VSCL Q31 D X_0R0402 18 19 20 21 22 23 24 25 R407 X_0R0402 FUTURE SPD UPGRADE R406 X_0R0402 39 6 17 28 G R166 R403 P2.0/A8 P2.1/A9 P2.2/A10 P2.3/A11 P2.4/A12 P2.5/A13 P2.6/A14 P2.7/A15 P1.0 P1.1 P1.2 P1.3 P1.4 P1.5 P1.6 P1.7 GND 1 R402 10KR0402 +3VRUN 40 41 42 43 44 1 2 3 S SST89V54RD2 316R1% 2 R162 C124 1KR1%0402 C0.1U10X0402 A RN13 C113 R131 C1U16Y 5.6KR0402 SDADDC Q30 D G A +3VRUN _N-FDV301N_SOT23 SDVO_CTRLDATA S 1 3 5 7 2 4 6 8 TX_DDC_SCL TX_DDC_SDA LSCL LSDA 1 _N-FDV301N_SOT23 8P4R-4.7KR0402 MSI CORPORATION Title SDVO- SiI1390 Size Document Number Custom Date: 5 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 1 Sheet 14 of 41 5 4 3 2 1 FSC Bit7 0 0 0 0 1 1 1 VDD_CK C373 C0.1U10X0402 C364 C0.1U10X0402 16 9 2 61 39 55 VDD_CK D C366 C0.1U10X0402 VDD_CLK_IO C378 C0.1U10X0402 12 20 26 45 36 49 IO_VOUT C363 C0.1U10X0402 48 C361 C0.1U10X0402 U12 VDD VDD48 VDDPCI VDDREF VDDSRC VDDCPU CPUCLKT0 CPUCLKC0 CPUCLKT1 CPUCLKC1 DOTC_96/SRCC0 DOTT_96/SRCT0 SRCCLKT1/SE1 SRCCLKC1/SE2 VIN SRCCLKT2/SATACL SRCCLKC2/SATACL VOUT C33P50N0402 PLL_XI SRCCLKT3/CR#_C SRCCLKC3/CR#_D 2 C79 Y2 14.31818MHZ20P_S-2 1 60 59 C33P50N0402 PLL_XO C78 C360 C4.7U6.3X5-1 SRCCLKT4 SRCCLKC4 X1 PCI_STOP#/SRCT5 CPU_STOP#/SRCC5 X2 D04-0100900-F07 H=1.3mm SRCCLKT6 SRCCLKC6 SRCCLKT7/CR#_F SRCCLKC7/CR#_E C 19 11,12,19,36 11,12,19,36 CLK_PWRGD 56 57 BSEL1 64 63 SMB_CLK_M2 SMB_DATA_M2 15 19 11 52 8 58 23 29 42 +3VRUN VDD_CK FB1 80L3_70_0805 R79 PCICLK0/CR#_A PCICLK1/CR#_B PCICLK2/LTE PCICLK3 PCICLK4/SRC5_EN GND GND GND48 GNDCPU GNDPCI GNDREF GNDSRC GNDSRC GNDSRC PCI_F5/ITP_EN USB_48MHZ/FSLA CLK_CPU_BCLK 3 CLK_CPU_BCLK# 3 51 50 MCHCLK MCHCLK# 33R0402 33R0402 R96 R97 CLK_MCH_BCLK 5 CLK_MCH_BCLK# 5 14 13 CK_DOT96# CK_DOT96 33R0402 33R0402 R159 R150 DREFCLK# DREFCLK 6 6 17 18 CK_PE_SRC1 CK_PE_SRC1# 33R0402 33R0402 R151 R152 DREFSSCLK DREFSSCLK# 6 6 21 22 CK_PE_SRC2 CK_PE_SRC2# 33R0402 33R0402 R153 R154 CLK_PCIE_SATA 17 CLK_PCIE_SATA# 17 24 25 CK_PE_SRC3 CK_PE_SRC3# 33R0402 33R0402 R147 R148 CLK_MINI0_PCIE 25 CLK_MINI0_PCIE- 25 27 28 CK_PE_SRC4 CK_PE_SRC4# 33R0402 33R0402 R155 R156 CLK_MINI1_PCIE 25 CLK_MINI1_PCIE- 25 38 37 CK_PE_SRC5 CK_PE_SRC5# 41 40 CK_PE_SRC6 CK_PE_SRC6# 33R0402 33R0402 R100 R101 CLK_PCIE_ICH 18 CLK_PCIE_ICH# 18 44 43 CK_PE_SRC7 CK_PE_SRC7# 33R0402 33R0402 R98 R99 CLK_PCIE_LAN 24 CLK_PCIE_LAN- 24 30 31 CK_PE_SRC9 CK_PE_SRC9# 33R0402 33R0402 R157 R149 CLK_NEW_CARD CLK_NEW_CARD- 33R0402 33R0402 R105 R104 CLK_PCIE_3GPLL 6 CLK_PCIE_3GPLL# 6 CK_PE_SRC10 CK_PE_SRC10# R102 R103 PM_STP_PCI# PM_STP_CPU# 0R0402 0R0402 D PM_STP_PCI# 19 PM_STP_CPU# 19 33 32 CR#H CR#G 475R1%0402 475R1%0402 R109 R158 CLK_MCH_OE# CLK_NEW_CARD_EN- 1 3 4 5 6 CR#A PCICLK1 PCICLK2 PCICLK3 PCICLK4 475R1%0402 33R0402 33R0402 33R0402 33R0402 R120 R133 R160 R141 R142 CLK_SATA_OE# 7 PCICLK5 33R0402 R146 PCLK_ICH 18 10 FSA 33R0402 R145 CLK_USB48 19 62 FSC 33R0402 R107 CLK_REF_ICH 19 C 26 26 CLK_MCH_OE# 6 CLK_NEW_CARD_EN- 26 CLK_SATA_OE# 19 LPC_TPM_CLK 26 LPC_DEBUG 21 LPC_EC_CLK 21 PCLK_CARD 23 R82 X_0R R144 For ICS9LPR501 33R0402 R94 R95 CPU MHz 266.66 133.33 200.00 166.66 333.33 100.00 400.00 ICS9LP505-1HGLF_TSSOP64-RH Q7 N-SST3904_SOT23 C54 X_C10P50N0402 B SRCCLKT11/CR#_H SRCCLKC11/CR#_G SCLK SDATA 33R0402 33R0402 34 35 SRCCLKT10 SRCCLKC10 FSLC/TST_SL/REF R71 15R0805 IO_VOUT SRCCLKT9 SRCCLKC9 CK_PWRGD/PD# FSLB/TEST_MODE CPUCLK CPUCLK# FSA Bit5 0 1 0 1 0 1 0 47 46 CPUT2_ITP/SRCT8 CPUC2_ITP/SRCC8 VDD96I/O VDDPLL3I/O VDDSRCI/O VDDSRCI/O VDDSRCI/O 54 53 FSB Bit6 0 0 1 1 0 0 1 VDD_CLK_IO 2.2KR0402 BSEL0 R108 10KR0402 B 0.8V PCICLK5 C377 C368 C376 C367 C49 C374 C375 C362 VDD_CK C0.1U10X0402 X_C10U10Y0805 C0.1U10X0402 C10U10Y0805 R165 R161 X_10KR0402 10KR0402 R164 R143 X_10KR0402 10KR0402 C0.1U10X0402 PCICLK4 C0.1U10X0402 C0.1U10X0402 For EMI reserve PULL-DOWN: pin46/47 as SRC8 pair LPC_DEBUG C128 X_C10P50N0402 LPC_EC_CLK C130 X_C10P50N0402 C0.1U10X0402 VDD_CK PULL-DOWN: pin37/38 as PCI_STOP# / CPU_STOP# PCLK_CARD C131 X_C10P50N0402 LPC_TPM_CLK C111 X_C10P50N0402 PCLK_ICH C132 X_C10P50N0402 CLK_USB48 C133 X_C10P50N0402 CLK_REF_ICH C80 X_C10P50N0402 PCICLK2 VDD_CK R168 10KR0402 3 3 CPU_BSEL0 CPU_BSEL1 R222 0R0402 BSEL0 R118 1KR0402 MCH_BSEL0 R219 0R0402 BSEL1 R93 1KR0402 MCH_BSEL1 R139 PULL-UP: No overclocking X_10KR0402 PIN# USAGE DESCRIPTION 1 CR#_A Control SRC2 pair 6 32 CR#_G Control SRC9 pair 6 33 CR#_H Control SRC10 pair A A N73-0200040-D02 H=1.42mm VTT SW2 1 2 4 3 BSEL0 BSEL1 R228 R227 MSI CORPORATION X_1KR0402 X_1KR0402 Title CLOCK Generator ( ICS9LP505-1 ) Size SW-DIP2S_black-NB Date: 5 [email protected] GRATIS - FOR FREE 4 Document Number Custom 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 15 of 41 5 4 +5VRUN 3 2 1 +5VRUN +5VRUN C0.1U10X0402 C13 D1 1 5 U2 1 5 U5 C0.1U10X0402 A C20 CRT5V S-BAS40WS_SOD323-RH CRT_HS 2 6 VGA_VSYNC_GM 4 CRT_VS _AHCT1G125DBVR_SOT23-5 CRT5V _AHCT1G125DBVR_SOT23-5 C3 C0.1U10X0402 3 R16 2.2KR0402 R15 2.2KR0402 R53 2.2KR0402 G 6 VGA_DATA CRT_DA R51 100R0402 CRT_CL R22 100R0402 CRT_HS CRT_VS R42 R26 33R0402 33R0402 D R58 150R1%0402 CRT_DA R45 150R1%0402 R32 150R1%0402 6 1 7 2 8 3 9 4 10 5 DDC2BD DDC2BC HSYN VSYN Q3 _N-BSS138_NL_SOT23-LF S LRED LGREEN LBLUE 60L500m_100 60L500m_100 60L500m_100 C32 C26 C14 C29 C8 C18 C10 C22P50N0402-1 C22P50N0402-1 C22P50N0402-1 C22P50N0402-1 C22P50N0402-1 C22P50N0402-1 C22P50N0402-1 C34 C21 C15 X_C22P50N0402-1 X_C22P50N0402-1 X_C22P50N0402-1 11 17 L4 L2 L1 VGA_R_GM VGA_G_GM VGA_B_GM 16 CON9 6 6 6 +3VRUN D 18 3 D 12 DDC2BD 13 HSYN 14 VSYN 15 DDC2BC 19 6 VGA_HSYNC_GM 4 C 2 CONN-VGA15F@_blue-RH-1 N59-15F0351-A10 SILM_DSUB_15PF_T +3VRUN C C R21 2.2KR0402 G Q2 _N-BSS138_NL_SOT23-LF 6 S VGA_CLK D +3VRUN CRT_CL PWR_SRC +3VRUN +3VSUS +3VRUN Q27 N-SI3456BDV-T1-E3_TSOP6-LF +3V_LCD +3V_LCD 6 5 2 1 3 D X_2.2KR0402 2.2KR0402 19 C0.1U10X0402 Q24 S G S LVDS_VDDEN# 6 6 LVDS_TXL0LVDS_TXL0+ 6 6 LVDS_TXL1LVDS_TXL1+ 6 6 LVDS_TXL2LVDS_TXL2+ 6 LVDS_TXLCLK6 LVDS_TXLCLK+ +3VRUN N-2N7002_SOT23 SOT23SGD_T +3VRUN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 PANEL_ID0 R302 47R1206 C0.01U25X0402 S R299 D DLVDS_VDDEN# C324 Q23 N-2N7002_SOT23 SOT23SGD_T G 6 LVDS_VDD_EN C323 C0.1U10X0402 B Q26 N-2N7002_SOT23 SOT23SGD_T G R304 JLCD1 C321 R310 100KR0402 C22U6.3X50805-RH R303 1MR0402 C317 4 R301 C0.1U10X0402 3 U22 2 1 C296 VDD GND VOUT 100KR0402 6 LVDS_DDC_CLK R286 10KR0402 LID- 6 LVDS_DDC_DATA LID- 21 C308 C1000P50X0402 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 PWR_SRC R297 2.2KR0402 R298 2.2KR0402 LVDS_DDC_CLK LVDS_DDC_DATA B CONN-LVDS20P_black-RH N5Q-20F0040-H21 LVC_D20SFYG APX9131AI-TRL_SOT23-3-RH +3VRUN I36-0913109-A30 +3VRUN L5 80L3_70_0805 +3VRUN R59 10KR0402 C42 C10U25X6S1206-RH C43 C47 C10U25X6S1206-RH C1000P50X0402 5 R54 X_0R0402 4 4 R52 U8 S08P5X_SC70 1 2 3 4 5 6 BL-ON 3 U6 S08P5X_SC70 A BL-ON 1 1 LVDS_BLON C322 C0.1U25Y 2 2 SB_BLON 6 LID- 21 3 19 5 A BR-AD-ADJ BR-AD-ADJ R56 100KR0402 MSI CORPORATION Title C39 C0.1U10X0402 X_100KR0402 CN4 VGA, LVDS ,BL _BH1X6_white-1.25pitch-NB C320 C0.1U10X0402 N32-1060170-H06 Size Document Number 53398_06 Custom MS-1221 Date: 5 4 3 2 Rev 0B Wednesday, September 06, 2006 Sheet 1 16 of 41 A B C119 C 2 Y4 2 RTCVCC R128 10MR1%0402 VTT 32.768KHZ12.5P_S-RH-2 R323 1 C15P50N0402 U9A RTCX1 RTCX2 C345 1 C352 C1U10X D_P1 AG25 AF24 R319 1MR0402 RTCRST# AF23 SM_INTRUDER# AD22 ICH_INTVRMEN LAN100_SLP AF25 AD21 C1U10X R325 R320 RTCVCC R318 332KR1% 332KR1% SM_INTRUDER# 1KR0402 B24 C21 B21 C22 4 RTC_P3 D22 1 2 CN3 BH1X2HBS_white-1.25pitch N32-1020290-H06 53398_02 D21 E20 C20 3 +1_5VRUN _BAT-CR2032 R309 RTCRST1 X_0R TP127 AH21 GLAN_COMPI D25 C25 RTCRST# 24.9R1%0402 HDA_BIT_CLK_ICH8 HDA_SYNC Within 0.5" with 10mils Trace 2 GLAN_DOCK# 27 CODEC_HDA_SDIN0 26 HDA_SDIN1 14 HDA_SDIN2 +3VRUN AJ16 AJ15 HDA_RST# AE14 HDA_SDIN3 AJ17 AH17 AH15 AD13 HDA_SDOUT AE13 GPIO33 HDA_DOCK_RST# AE10 AG14 SATA_ACTIVE# AF10 TP112 R335 8.2KR0402 30 GPIO33 22 22 22 22 22 SATA_ACTIVE# C3900P50X SATA0RXN C3900P50X SATA0RXP C3900P50X SATA0TXN C3900P50X SATA0TXP TP39 GPIO33 C89 C85 C97 C100 SATA0RXN_C SATA0RXP_C SATA0TXN_C SATA0TXP_C AF6 AF5 AH5 AH6 AG3 AG4 AJ4 AJ3 AF2 AF1 AE4 AE3 AB7 AC6 15 CLK_PCIE_SATA# 15 CLK_PCIE_SATA SATARBIAS 3 Trace <0.5" R113 AG1 AG2 FWH0/LAD0 FWH1/LAD1 FWH2/LAD2 FWH3/LAD3 RTCX1 RTCX2 RTCRST# FWH4/LFRAME# INTRUDER# RTC LPC C118 INTVRMEN LAN100_SLP LDRQ0# LDRQ1#/GPIO23 A20GATE A20M# GLAN_CLK LAN_RSTSYNC DPRSTP# DPSLP# LAN_RXD0 LAN_RXD1 LAN_RXD2 LAN / GLAN CPU RTCRST# 20KR0402-2 LAN_TXD0 LAN_TXD1 LAN_TXD2 FERR# CPUPWRGD/GPIO49 GLAN_DOCK#/GPIO13 GLAN_COMPI GLAN_COMPO IGNNE# INIT# INTR RCIN# NMI SMI# HDA_BIT_CLK HDA_SYNC STPCLK# HDA_RST# THRMTRIP# HDA_SDIN0 HDA_SDIN1 HDA_SDIN2 HDA_SDIN3 TP8 IHDA 3 S-BAT54C_SOT23 HDA_SDOUT DD0 DD1 DD2 DD3 DD4 DD5 DD6 DD7 DD8 DD9 DD10 DD11 DD12 DD13 DD14 DD15 HDA_DOCK_EN#/GPIO33 HDA_DOCK_RST#/GPIO34 SATALED# SATA0RXN SATA0RXP SATA0TXN SATA0TXP SATA1RXN SATA1RXP SATA1TXN SATA1TXP SATA IDE DT1 BAT1 E C15P50N0402 +3VALW 1 D SATA2RXN SATA2RXP SATA2TXN SATA2TXP DA0 DA1 DA2 DCS1# DCS3# SATA_CLKN SATA_CLKP DIOR# DIOW# DDACK# IDEIRQ IORDY DDREQ SATARBIAS# SATARBIAS E5 F5 G8 F6 LAD0 LAD1 LAD2 LAD3 LAD0 LAD1 LAD2 LAD3 C4 G9 E6 21,26 21,26 21,26 21,26 LPC_FRAME# LDRQ1# L_LDRQ0# TP108 R331 R338 X_56R0402 H_DPRSTP# H_DPSLP# 21,26 1 X_56R0402 H_DPRSTP# H_DPSLP# 3,6,34 3 21 VTT AF13 AG26 AF26 AE26 DPRSTP# DPSLP# H_A20GATE 21 H_A20M# 3 0R0402 H_DPRSTP# H_DPSLP# 0R0402 R336 R332 R327 56R0402 AD24 H_FERR# AG29 AF27 AE24 AC20 AH14 AD23 AG28 INIT# 3 H_IGNNE# R330 3 H_INTR KBRST# H_NMI 3 21 3 SMI# 0R0402 AE27 THRMTRIP# AA23 TP8 R334 H_STPCLK# 24.9R1%0402 H_INIT# 3 3 VTT R339 AA24 V1 U2 V3 T1 V4 T5 AB2 T6 T3 R2 T4 V6 V5 U1 V2 U6 H_PWRGD 0R0402 H_SMI# 3 R333 3 56R0402 PM_THRMTRIP# PM_THRMTRIP# 3,6 2 TP111 IDE_PDD[15:0] IDE_PDD0 IDE_PDD1 IDE_PDD2 IDE_PDD3 IDE_PDD4 IDE_PDD5 IDE_PDD6 IDE_PDD7 IDE_PDD8 IDE_PDD9 IDE_PDD10 IDE_PDD11 IDE_PDD12 IDE_PDD13 IDE_PDD14 IDE_PDD15 AA4 AA1 AB3 Y6 Y5 W4 W3 Y2 Y3 Y1 W5 IDE_PDA0 IDE_PDA1 IDE_PDA2 22 22 22 IDE_PDCS1# IDE_PDCS3# 22 22 IDE_PDIOR# IDE_PDIOW# IDE_PDDACK# INT_IRQ14 IDE_PIORDY IDE_PDDREQ 22 22 22 22 22 22 22 Place R close to ICH within 2" 3 ICH8M REV 1.0 24.9R1%0402 HDA_SYNC R348 33R0402 R354 33R0402 R351 33R0402 CODEC_HDA_SYNC HDA_SDOUT 27 MDC_HDA_SYNC 26 HDMI_HDA_SYNC 14 R350 33R0402 CODEC_HDA_SDOUT R355 33R0402 MDC_HDA_SDOUT 26 R349 33R0402 HDMI_HDA_SDOUT 14 C383 C379 C380 X_C33P50N0402 X_C33P50N0402 X_C33P50N0402 HDA_BIT_CLK_ICH8 4 R121 33R0402 CODEC_HDA_BITCLK R137 33R0402 MDC_HDA_BIT_CLK R134 C381 C384 X_C33P50N0402 X_C33P50N0402 27,36 27 CODEC_HDA_RST# HDMI_HDA_BIT_CLK C121 C129 C122 C382 X_C33P50N0402 CODEC_HDA_RST# R357 33R0402 MDC_HDA_RST# R358 33R0402 HDMI_HDA_RST# R356 33R0402 HDA_RST# 4 26 26 MDC_HDA_RST# 33R0402 27 14 14 HDMI_HDA_RST# MSI CORPORATION X_C33P50N0402 X_C33P50N0402 X_C33P50N0402 Title Place R close to ICH8 within ICH8M-1 (CPU/IDE/Azalia) 2" Size Document Number Custom Date: A [email protected] GRATIS - FOR FREE B C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 17 of 41 A B place Cap close to ICH8 within 250mils 24 24 24 24 PCIE_GLAN_RXN PCIE_GLAN_RXP PCIE_GLAN_TXN PCIE_GLAN_TXP 25 25 25 25 PCIE_MINI0_RXN PCIE_MINI0_RXP PCIE_MINI0_TXN PCIE_MINI0_TXP 25 25 25 25 PCIE_MINI1_RXN PCIE_MINI1_RXP PCIE_MINI1_TXN PCIE_MINI1_TXP C40 C41 C37 C33 C30 C28 C27 C23 C0.1U10X0402PETN1 C0.1U10X0402PETP1 C0.1U10X0402PETN2 C0.1U10X0402PETP2 M27 M26 L29 L28 C0.1U10X0402PETN3 C0.1U10X0402PETP3 K27 K26 J29 J28 C0.1U10X0402PETN4 C0.1U10X0402PETP4 H27 H26 G29 G28 F27 F26 E29 E28 D27 D26 C29 C28 +3VSUS 2 OC6# OC2# OC3# OC4# RN9 1 3 5 7 C23 B23 E22 8P4R-10KR0402 2 4 6 8 D23 F21 +3VSUS OC1# OC7# OC5# OC0# RN10 1 3 5 7 OC8# OC9# R326 R346 8P4R-10KR0402 2 4 6 8 OC0# OC1# OC2# OC3# OC4# OC5# OC6# OC7# OC8# OC9# D E U9D P27 P26 N29 N28 AJ19 AG16 AG15 AE15 AF15 AG17 AD12 AJ18 AD14 AH18 PERN1 PERP1 PETN1 PETP1 PCI-Express Direct Media Interface 1 PCIE_NEWCARD_RXN PCIE_NEWCARD_RXP PCIE_NEWCARD_TXN PCIE_NEWCARD_TXP PERN2 PERP2 PETN2 PETP2 PERN3 PERP3 PETN3 PETP3 PERN4 PERP4 PETN4 PETP4 PERN5 PERP5 PETN5 PETP5 DMI0RXN DMI0RXP DMI0TXN DMI0TXP DMI1RXN DMI1RXP DMI1TXN DMI1TXP DMI2RXN DMI2RXP DMI2TXN DMI2TXP DMI3RXN DMI3RXP DMI3TXN DMI3TXP DMI_CLKN DMI_CLKP DMI_ZCOMP DMI_IRCOMP PERN6/GLAN_RXN PERP6/GLAN_RXP PETN6/GLAN_TXN PETP6/GLAN_TXP SPI_CLK SPI_CS0# SPI_CS1# SPI 26 26 26 26 C SPI_MOSI SPI_MISO OC0# OC1#/GPIO40 OC2#/GPIO41 OC3#/GPIO42 OC4#/GPIO43 OC5#/GPIO29 OC6#/GPIO30 OC7#/GPIO31 OC8# OC9# USB USBP0N USBP0P USBP1N USBP1P USBP2N USBP2P USBP3N USBP3P USBP4N USBP4P USBP5N USBP5P USBP6N USBP6P USBP7N USBP7P USBP8N USBP8P USBP9N USBP9P USBRBIAS# USBRBIAS 10KR0402 10KR0402 V27 V26 U29 U28 DMI_RXN0 DMI_RXP0 DMI_TXN0 DMI_TXP0 Y27 Y26 W29 W28 AB26 AB25 AA29 AA28 AD27 AD26 AC29 AC28 T26 T25 F2 F3 DMI_RXN1 DMI_RXP1 DMI_TXN1 DMI_TXP1 6 6 6 6 DMI_RXN2 DMI_RXP2 DMI_TXN2 DMI_TXP2 6 6 6 6 DMI_RXN3 DMI_RXP3 DMI_TXN3 DMI_TXP3 6 6 6 6 23 PCI_AD[31:0] +1_5VRUN CLK_PCIE_ICH# 15 CLK_PCIE_ICH 15 R322 24.9R1%0402 Y23 Y24 G3 G2 H5 H4 H2 H1 J3 J2 K5 K4 K2 K1 L3 L2 M5 M4 M2 M1 N3 N2 6 6 6 6 DMI_ZCOMP USBP0N USBP0P USBP1N USBP1P USBP2N USBP2P USBP3N USBP3P USBP4N USBP4P USBP5N USBP5P USBP6N USBP6P USBP7N USBP7P USBP9N USBP9P USBP0N USBP0P USBP1N USBP1P USBP2N USBP2P USBP3N USBP3P USBP4N USBP4P USBP5N USBP5P USBP6N USBP6P USBP7N USBP7P 22Trace within 220.5" with 8mils 25 25 22 22 25 25 22 22 22 22 23 INT_PIRQA# 22 22 22 22 USBP9N USBP9P 26 26 U9B PCI_AD0 PCI_AD1 PCI_AD2 PCI_AD3 PCI_AD4 PCI_AD5 PCI_AD6 PCI_AD7 PCI_AD8 PCI_AD9 PCI_AD10 PCI_AD11 PCI_AD12 PCI_AD13 PCI_AD14 PCI_AD15 PCI_AD16 PCI_AD17 PCI_AD18 PCI_AD19 PCI_AD20 PCI_AD21 PCI_AD22 PCI_AD23 PCI_AD24 PCI_AD25 PCI_AD26 PCI_AD27 PCI_AD28 PCI_AD29 PCI_AD30 PCI_AD31 D20 E19 D19 A20 D17 A21 A19 C19 A18 B16 A12 E16 A14 G16 A15 B6 C11 A9 D11 B12 C12 D10 C7 F13 E11 E13 E12 D8 A6 E8 D6 A3 INT_PIRQA# INT_PIRQB# INT_PIRQC# INT_PIRQD# F9 B5 C5 A10 AD0 AD1 AD2 AD3 AD4 AD5 AD6 AD7 AD8 AD9 AD10 AD11 AD12 AD13 AD14 AD15 AD16 AD17 AD18 AD19 AD20 AD21 AD22 AD23 AD24 AD25 AD26 AD27 AD28 AD29 AD30 AD31 REQ0# GNT0# REQ1#/GPIO50 GNT1#/GPIO51 REQ2#/GPIO52 GNT2#/GPIO53 REQ3#/GPIO54 GNT3#/GPIO55 PCI C/BE0# C/BE1# C/BE2# C/BE3# IRDY# PAR PCIRST# DEVSEL# PERR# PLOCK# SERR# STOP# TRDY# FRAME# PLTRST# PCICLK PME# Interrupt I/F PIRQA# PIRQB# PIRQC# PIRQD# PIRQE#/GPIO2 PIRQF#/GPIO3 PIRQG#/GPIO4 PIRQH#/GPIO5 A4 D7 E18 C18 B19 F18 A11 C10 PCI_REQ#0 PCI_GNT#0 PCI_REQ#1 GNT1# PCI_REQ#2 GNT2# PCI_REQ#3 GNT3# 1 TP8 TP10 TP106 C17 E15 F16 E17 PCI_CBE#0 PCI_CBE#1 PCI_CBE#2 PCI_CBE#3 C8 D9 G6 D16 A7 B7 F10 C16 C9 A17 PCI_IRDY# PCI_PAR PCI_RST# R313 PCI_DEVSEL# PCI_PERR# PCI_LOCK# PCI_SERR# PCI_STOP# PCI_TRDY# PCI_FRAME# AG24 B10 G7 PLT_RST# PCLK_ICH PCI_PME# F8 G11 F12 B3 INT_PIRQE# INT_PIRQF# INT_PIRQG# INT_PIRQH# PCI_CBE#0 PCI_CBE#1 PCI_CBE#2 PCI_CBE#3 23 23 23 23 PCI_IRDY# 23 PCI_PAR 23 CARD_RST# 23 PCI_DEVSEL# 23 PCI_PERR# 23 0R0402 PCI_SERR# 23 PCI_STOP# 23 PCI_TRDY# 23 PCI_FRAME# 23 PCLK_ICH PCI_PME# 2 15 23 ICH8M REV 1.0 USBRBIAS ICH8M REV 1.0 R116 33R0402 R172 33R0402 R29 33R0402 R115 33R0402 R176 33R0402 R314 Trace <0.5" PLT_RST# 22.6R1%0402 3 +3VRUN 23 23 LPC_RST# 21,26 IDE1_RST# 22 3 MINIPCIE0_RST# 25 LAN_RST# 24 NB_RST# 6 +3VRUN +3VSUS 8P4R-8.2KR0402-1 PCI_REQ#3 2 INT_PIRQD# 4 6 PCI_PERR# INT_PIRQG# 8 RN5 1 3 5 7 8P4R-8.2KR0402-1 PCI_LOCK# 2 INT_PIRQB# 4 6 INT_PIRQC# INT_PIRQH# 8 RN1 1 3 5 7 8P4R-8.2KR0402-1 INT_PIRQF# 2 PCI_SERR# 4 PCI_REQ#0 6 8 RN2 1 3 5 7 8P4R-8.2KR0402-1 INT_PIRQE# 2 PCI_TRDY# 4 PCI_IRDY# 6 INT_PIRQA# 8 RN4 1 3 5 7 8P4R-8.2KR0402-1 2 PCI_FRAME# PCI_STOP# 4 PCI_DEVSEL# 6 8 C135 C0.1U10X0402 5 RN3 1 3 5 7 2 4 R308 8.2KR0402 PCI_REQ#1 R25 8.2KR0402 PCI_REQ#2 4 1 3 U16 S08P5X_SC70 RN8 1 3 5 7 2 4 6 8 SDVO_RST# 14 MINIPCIE1_RST# 25 NEWCARD_RST# 26 CODEC_RST# 27 8P4R-33R0402 4 MSI CORPORATION Title ICH8M-2 (PCI/USB/PCIE/DMI) Size Document Number Custom Date: A B C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 18 of 41 A B C D E +3VRUN R340 10KR0402 PM_BMBUSY# R76 10KR0402 CLK_SATA_OE# R129 10KR0402 SB_GPIO24 R324 10KR0402 R328 10KR0402 R337 10KR0402 P_CLKRUN# 100KR0402 AF17 LPCPD# PM_SYS_RESET F4 AD15 PM_BMBUSY# AG12 SMBALERT# AG22 STP_PCI#_R STP_CPU#_R AE20 AG18 P_CLKRUN# AH11 PCIE_WAKE# SIRQ PM_THRM# AE17 AF12 AC13 VR_PWRGD_CLKEN AJ20 26 IMVP_PWRGD LPCPD# 6 PM_BMBUSY# +3VSUS RN12 1 3 5 7 23,26 P_CLKRUN# 8P4R-10KR0402 2 4 6 8 SMBALERT# SMB_LINK_ALERT# SMLINK1 SMLINK0 R352 10KR0402 PM_SYS_RESET R110 2.2KR0402 SUS_SMBDATA 24,25,26 PCIE_WAKE# 21,23,26 SIRQ TP123 AJ22 TP7 2 R122 2.2KR0402 R347 10KR0402 PM_RI# R138 10KR0402 PM_BATLOW# SUS_SMBCLK R124 1KR0402 PCIE_WAKE# R312 10KR0402 PM_PWRBTN# R329 10KR0402 SB_BLON 21 KBSMI# 21 16 KBSCI# PANEL_ID0 16 TP38 TP114 TP118 SB_BLON TP121 TP126 TP115 15 CLK_SATA_OE# 6 MCH_ICH_SYNC# 27 R342 TP120 SPKR 0R0402 AJ8 AJ9 SB_GPIO6 AH9 AE16 SB_GPIO12 AC19 AG8 SB_GPIO17 AH12 AE11 SB_GPIO22 AG10 SB_GPIO27 AH25 SB_GPIO28 AD16 AG13 AF9 SB_GPIO38 MB_ID0 AJ11 MB_ID1 AD10 AD9 MCH_SYNC# AJ13 TP43 AJ21 TP3 RI# SUS_STAT#/LPCPD# SYS_RESET# SATA GPIO PM_RI# Clocks SIRQ SATA0GP/GPIO21 SATA1GP/GPIO19 SATA2GP/GPIO36 SATA3GP/GPIO37 CLK14 CLK48 SUSCLK SLP_S3# SLP_S4# SLP_S5# BMBUSY#/GPIO0 SMBALERT#/GPIO11 STP_PCI#/GPIO15 STP_CPU#/GPIO25 CLKRUN#/GPIO32 WAKE# SERIRQ THRM# VRMPWRGD TP7 TACH1/GPIO1 TACH2/GPIO6 TACH3/GPIO7 GPIO8 GPIO12 TACH0/GPIO17 GPIO18 GPIO20 SCLOCK/GPIO22 QRT_STATE0/GPIO27 QRT_STATE1/GPIO28 SATACLKREQ#/GPIO35 SLOAD/GPIO38 SDATAOUT0/GPIO39 SDATAOUT1/GPIO48 SPKR MCH_SYNC# TP3 ICH8M REV 1.0 SYS GPIO Power MGT R353 PM_THRM# SMBCLK SMBDATA LINKALERT# SMLINK0 SMLINK1 S4_STATE#/GPIO26 PWROK DPRSLPVR/GPIO16 BATLOW# PWRBTN# LAN_RST# RSMRST# CK_PWRGD CLPWROK SLP_M# MISC GPIO Controller Link 1 AJ26 AD19 AG21 AC17 AE19 SMB U9C SUS_SMBCLK SUS_SMBDATA SMB_LINK_ALERT# SMLINK0 SMLINK1 CL_CLK0 CL_CLK1 CL_DATA0 CL_DATA1 CL_VREF0 CL_VREF1 CL_RST# MEM_LED/GPIO24 ME_EC_ALERT/GPIO10 EC_ME_ALERT/GPIO14 WOL_EN/GPIO9 AJ12 AJ10 AF11 AG11 SATA1GP SATA3GP SATA2GP SATA0GP SATA0GP SATA1GP SATA2GP SATA3GP AG9 G5 D3 RN11 1 3 5 7 TP14 SUSCLK SLP_S3# SLP_S4# AH27 S4_STATE# AE23 PWROK_SB AJ14 DPRSLPVR AE21 PM_BATLOW# C2 PM_PWRBTN# AH20 SB_LAN_RST# AG27 RSM_RST# R345 R136 100R0402 100R0402 PM_SLP_S3# PM_SLP_S4# PM_SLP_S5# R344 0R0402 R343 IMVP_PWRGD 6,34 100R0402 PM_DPRSLPVR 6,34 PM_PWRBTN# 21 R126 10KR0402 R341 100R0402 E3 RSMRST# 3,21 CLK_PWRGD 15 MPWROK 6,21 2 TP41 SLP_M# F23 AE18 SB_CL_CLK0 TP117 R316 0R0402 CL_CLK1 F22 AF19 SB_CL_DATA0 TP124 CL_DATA1 R317 0R0402 D24 AH23 CL_VREF0_ICH CL_VREF1_ICH R127 0R0402 AJ27 AJ24 AF22 AG19 21 21 21 TP40 E1 AJ23 1 CLK_REF_ICH 15 CLK_USB48 15 AG23 AF21 AD18 AJ25 8P4R-100R0402 2 4 6 8 CL_CLK0 6 CL_DATA0 6 CL_RST#0 6 TP125 SB_CL_RST# SB_GPIO24 SB_GPIO10 SB_GPIO14 SB_GPIO9 TP42 TP116 TP122 +3VRUN +3VRUN 3 3 5 8/22 U13 2 34 VR_PWRGD_CLKEN# R307 3.24KR1% 4 VR_PWRGD_CLKEN 3 CL_VREF0_ICH LVC1G04_SOT23-5 R125 100KR0402 +3VRUN C327 R311 C0.1U10X0402 453R1% +3VRUN R119 2.2KR0402 G Q11 R70 25,26 SUS_SMBCLK R62 10KR0402 SUS_SMBCLK D +3VRUN _N-BSS138_NL_SOT23-LF S To NewCard, MiniCard X_10KR0402 SW1 SMB_CLK_M2 11,12,15,36 1 2 To DDR-SODIMM, CLK Gen. 4 3 MB_ID0 MB_ID1 R92 R106 100KR0402 100KR0402 +3VRUN X_SW-DIP2S_black-NB 4 4 15 PM_STP_PCI# A 15 PM_STP_CPU# DB6 S-RB551V-30_SOD323 C STP_PCI#_R C R114 2.2KR0402 STP_CPU#_R MSI CORPORATION G DB5 A X_S-RB551V-30_SOD323 25,26 SUS_SMBDATA SUS_SMBDATA D Title S ICH8M-3 (SM BUS/GPIO) SMB_DATA_M2 11,12,15,36 Size Q10 Custom _N-BSS138_NL_SOT23-LF A [email protected] GRATIS - FOR FREE B Document Number C Date: D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 19 of 41 A D E RTCVCC D8 C348 S-RB551V-30_SOD323 U9E U9F C0.1U10X0402 +3VSUS A +5VSUS R315 10R0402 D7 S-RB551V-30_SOD323 C V5REF_SUS C330 C0.1U10X0402 1 + C16 C338 C354 C100U6.3POS C491 C0.1U10X0402 C4.7U6.3X5-1 2 C0.1U10X0402 +1_5VRUN L31 1U500m_0805-RH C372 C371 C10U6.3X50805-1 C1U10X C353 AJ6 C333 AE7 AF7 AG7 AH7 AJ7 C1U10X +1_5VRUN AC10 AC9 3 C370 C490 C0.1U10X0402 AA5 AA6 C0.1U10X0402 G12 G17 H7 C337 AC7 AD7 C0.1U10X0402 D1 C350 +1_5VRUN C0.1U10X0402 F1 L6 L7 M6 M7 W23 VCCLAN1_05_1 VCCLAN1_05_2 TP107 TP109 F17 G18 F19 G20 +1_5VRUN A24 C0.1U10X0402 4 +3VRUN A26 A27 B26 B27 B28 B25 VCC3_3[07] VCC3_3[08] VCC3_3[09] VCC3_3[10] VCC3_3[11] VCC3_3[12] VCC3_3[13] VCC3_3[14] VCC3_3[15] VCC3_3[16] VCC3_3[17] VCC3_3[18] VCC3_3[19] VCC3_3[20] VCC3_3[21] VCC3_3[22] VCC3_3[23] VCC3_3[24] VCCSUSHDA VCC1_5_A[11] VCC1_5_A[12] VCCSUS1_05[1] VCCSUS1_05[2] VCC1_5_A[13] VCC1_5_A[14] VCCSUS1_5[1] VCC1_5_A[15] VCC1_5_A[16] VCC1_5_A[17] VCCSUS1_5[2] VCCSUS3_3[01] VCC1_5_A[18] VCC1_5_A[19] VCCUSBPLL VCC1_5_A[20] VCC1_5_A[21] VCC1_5_A[22] VCC1_5_A[23] VCC1_5_A[24] VCC1_5_A[25] VCCLAN1_05[1] VCCLAN1_05[2] VCCLAN3_3[1] VCCLAN3_3[2] VCCGLANPLL VCCGLAN1_5[1] VCCGLAN1_5[2] VCCGLAN1_5[3] VCCGLAN1_5[4] VCCGLAN1_5[5] GLAN POWER C5 VCC3_3[03] VCC3_3[04] VCC3_3[05] VCC3_3[06] VCCHDA USB CORE +3VRUN VCC1_5_A[06] VCC1_5_A[07] VCC1_5_A[08] VCC1_5_A[09] VCC1_5_A[10] VCC_DMI[1] VCC_DMI[2] VCC3_3[02] ATX AC1 AC2 AC3 AC4 AC5 VCCDMIPLL VCC3_3[01] VCCSATAPLL VCC1_5_A[01] VCC1_5_A[02] VCC1_5_A[03] VCC1_5_A[04] VCC1_5_A[05] VCC1_05[01] VCC1_05[02] VCC1_05[03] VCC1_05[04] VCC1_05[05] VCC1_05[06] VCC1_05[07] VCC1_05[08] VCC1_05[09] VCC1_05[10] VCC1_05[11] VCC1_05[12] VCC1_05[13] VCC1_05[14] VCC1_05[15] VCC1_05[16] VCC1_05[17] VCC1_05[18] VCC1_05[19] VCC1_05[20] VCC1_05[21] VCC1_05[22] VCC1_05[23] VCC1_05[24] VCC1_05[25] VCC1_05[26] VCC1_05[27] VCC1_05[28] V_CPU_IO[1] V_CPU_IO[2] ARX C1U10X VCC1_5_B[01] VCC1_5_B[02] VCC1_5_B[03] VCC1_5_B[04] VCC1_5_B[05] VCC1_5_B[06] VCC1_5_B[07] VCC1_5_B[08] VCC1_5_B[09] VCC1_5_B[10] VCC1_5_B[11] VCC1_5_B[12] VCC1_5_B[13] VCC1_5_B[14] VCC1_5_B[15] VCC1_5_B[16] VCC1_5_B[17] VCC1_5_B[18] VCC1_5_B[19] VCC1_5_B[20] VCC1_5_B[21] VCC1_5_B[22] VCC1_5_B[23] VCC1_5_B[24] VCC1_5_B[25] VCC1_5_B[26] VCC1_5_B[27] VCC1_5_B[28] VCC1_5_B[29] VCC1_5_B[30] VCC1_5_B[31] VCC1_5_B[32] VCC1_5_B[33] VCC1_5_B[34] VCC1_5_B[35] VCC1_5_B[36] VCC1_5_B[37] VCC1_5_B[38] VCC1_5_B[39] VCC1_5_B[40] VCC1_5_B[41] VCC1_5_B[42] VCC1_5_B[43] VCC1_5_B[44] VCC1_5_B[45] VCC1_5_B[46] VCCA3GP +1_5VRUN AA25 AA26 AA27 AB27 AB28 AB29 D28 D29 E25 E26 E27 F24 F25 G24 H23 H24 J23 J24 K24 K25 L23 L24 L25 M24 M25 N23 N24 N25 P24 P25 R24 R25 R26 R27 T23 T24 T27 T28 T29 U24 U25 V23 V24 V25 W25 Y25 V5REF_SUS CORE G4 V5REF[1] V5REF[2] VCCP_CORE A16 T7 IDE V5REF C347 1 VCCRTC PCI C AD25 VTT VCCPSUS C0.1U10X0402 VCCPUSB R321 100R0402 2 C +3VRUN A +5VRUN B VCCSUS3_3[02] VCCSUS3_3[03] VCCSUS3_3[04] VCCSUS3_3[05] VCCSUS3_3[06] VCCSUS3_3[07] VCCSUS3_3[08] VCCSUS3_3[09] VCCSUS3_3[10] VCCSUS3_3[11] VCCSUS3_3[12] VCCSUS3_3[13] VCCSUS3_3[14] VCCSUS3_3[15] VCCSUS3_3[16] VCCSUS3_3[17] VCCSUS3_3[18] VCCSUS3_3[19] VCCCL1_05 VCCCL1_5 VCCCL3_3[1] VCCCL3_3[2] A13 B13 C13 C14 D14 E14 F14 G14 L11 L12 L14 L16 L17 L18 M11 M18 P11 P18 T11 T18 U11 U18 V11 V12 V14 V16 V17 V18 C342 C349 C0.1U10X0402 A23 A5 AA2 AA7 A25 AB1 AB24 AC11 AC14 AC25 AC26 AC27 AD17 AD20 AD28 AD29 AD3 AD4 AD6 AE1 AE12 AE2 AE22 AD1 AE25 AE5 AE6 AE9 AF14 AF16 AF18 AF3 AF4 AG5 AG6 AH10 AH13 AH16 AH19 AH2 AF28 AH22 AH24 AH26 AH3 AH4 AH8 AJ5 B11 B14 B17 B2 B20 B22 B8 C24 C26 C27 C6 D12 D15 D18 D2 D4 E21 E24 E4 E9 F15 E23 F28 F29 F7 G1 E2 G10 G13 G19 G23 G25 G26 G27 H25 H28 H29 H3 H6 J1 J25 J26 J27 J4 J5 K23 K28 K29 K3 K6 C336 C0.1U10X0402 C10U6.3X50805-1 +1_5VRUN L9 VCCDMIPLL C46 1U500m_0805-RH C45 C0.1U10X0402 C10U6.3X50805-1 +1_25VRUN C84 C489 C0.1U10X0402 C22U6.3X50805-RH VTT R29 C344 AE28 AE29 C335 C332 C0.1U10X0402 C0.1U10X0402 C4.7U6.3X5-1 AC23 AC24 +3VRUN AF29 C331 AD2 C0.1U10X0402 C359 AC8 AD8 AE8 AF8 C0.1U10X0402 C91 C0.1U10X0402 AA3 U7 V7 W1 W6 W7 Y7 C325 C0.1U10X0402 A8 B15 B18 B4 B9 C15 D13 D5 E10 E7 F11 C329 C328 C346 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 +3VRUN C358 C0.1U10X0402 +3VSUS AC12 AD11 J6 AF20 VCCSUS1_05_1 VCCSUS1_05_2 TP18 TP119 AC16 VCCSUS1_5_1 TP113 J7 VCCSUS1_5_2 TP19 C355 C0.1U10X0402 +3VSUS C3 AC18 AC21 AC22 AG20 AH28 C357 C341 C0.1U10X0402 C0.1U10X0402 P6 P7 C1 N7 P1 P2 P3 P4 P5 R1 R3 R5 R6 C343 C4.7U6.3X5-1 G22 VCCCL1_05 TP110 A22 VCCCL1_5 TP11 VSS[001] VSS[002] VSS[003] VSS[004] VSS[005] VSS[006] VSS[007] VSS[008] VSS[009] VSS[010] VSS[011] VSS[012] VSS[013] VSS[014] VSS[015] VSS[016] VSS[017] VSS[018] VSS[019] VSS[020] VSS[021] VSS[022] VSS[023] VSS[024] VSS[025] VSS[026] VSS[027] VSS[028] VSS[029] VSS[030] VSS[031] VSS[032] VSS[033] VSS[034] VSS[035] VSS[036] VSS[037] VSS[038] VSS[039] VSS[040] VSS[041] VSS[042] VSS[043] VSS[044] VSS[045] VSS[046] VSS[047] VSS[048] VSS[049] VSS[050] VSS[051] VSS[052] VSS[053] VSS[054] VSS[055] VSS[056] VSS[057] VSS[058] VSS[059] VSS[060] VSS[061] VSS[062] VSS[063] VSS[064] VSS[065] VSS[066] VSS[067] VSS[068] VSS[069] VSS[070] VSS[071] VSS[072] VSS[073] VSS[074] VSS[075] VSS[076] VSS[077] VSS[078] VSS[079] VSS[080] VSS[081] VSS[082] VSS[083] VSS[084] VSS[085] VSS[086] VSS[087] VSS[088] VSS[089] VSS[090] VSS[091] VSS[092] VSS[093] VSS[094] VSS[095] VSS[096] VSS[097] VSS[098] VSS[099] VSS[100] VSS[101] VSS[102] VSS[103] VSS[104] VSS[105] VSS[106] VSS[107] VSS[108] VSS[109] VSS[110] VSS[111] VSS[112] VSS[113] VSS[114] VSS[115] VSS[116] VSS[117] VSS[118] VSS[119] VSS[120] VSS[121] VSS[122] VSS[123] VSS[124] VSS[125] VSS[126] VSS[127] VSS[128] VSS[129] VSS[130] VSS[131] VSS[132] VSS[133] VSS[134] VSS[135] VSS[136] VSS[137] VSS[138] VSS[139] VSS[140] VSS[141] VSS[142] VSS[143] VSS[144] VSS[145] VSS[146] VSS[147] VSS[148] VSS[149] VSS[150] VSS[151] VSS[152] VSS[153] VSS[154] VSS[155] VSS[156] VSS[157] VSS[158] VSS[159] VSS[160] VSS[161] VSS[162] VSS[163] VSS[164] VSS[165] VSS[166] VSS[167] VSS[168] VSS[169] VSS[170] VSS[171] VSS[172] VSS[173] VSS[174] VSS[175] VSS[176] VSS[177] VSS[178] VSS[179] VSS[180] VSS[181] VSS[182] VSS[183] VSS[184] VSS_NCTF[01] VSS_NCTF[02] VSS_NCTF[03] VSS_NCTF[04] VSS_NCTF[05] VSS_NCTF[06] VSS_NCTF[07] VSS_NCTF[08] VSS_NCTF[09] VSS_NCTF[10] VSS_NCTF[11] VSS_NCTF[12] K7 L1 L13 L15 L26 L27 L4 L5 M12 M13 M14 M15 M16 M17 M23 M28 M29 M3 N1 N11 N12 N13 N14 N15 N16 N17 N18 N26 N27 N4 N5 N6 P12 P13 P14 P15 P16 P17 P23 P28 P29 R11 R12 R13 R14 R15 R16 R17 R18 R28 R4 T12 T13 T14 T15 T16 T17 T2 U12 U13 U14 U15 U16 U17 U23 U26 U27 U3 U5 V13 V15 V28 V29 W2 W26 W27 Y28 Y29 Y4 AB4 AB23 AB5 AB6 AD5 U4 W24 1 2 3 A1 A2 A28 A29 AH1 AH29 AJ1 AJ2 AJ28 AJ29 B1 B29 ICH8M REV 1.0 4 +3VRUN F20 G21 VCCGLAN3_3 ICH8M REV 1.0 MSI CORPORATION Title ICH8M-4 (POWER/GND) Size Document Number Cus tom Date: A B C D Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet E 20 of 41 3 2 CON1 +3VALW +3VALW UB1 BH1X14HS_white-RH N32-1140060-M0 6 53398_14 EC_CLKRUN# TP25 +3VRUN RB11 17 17 R74 10KR0402 KBSMI# R75 10KR0402 KBSCI# RT4 10KR0402 H_A20GA TE RB7 10KR0402 KBRST# H_A20GA TE H_A20GA TE 19 PM_PWRBTN# 19 KBSCI# 19 KBSMI# C1U16Y Close to Pin19 S-RB551V-30_SOD323 KB_RESETC DB2 A S-RB551V-30_SOD323 KB_PWRBTC KBSCI# DB8 A S-RB551V-30_SOD323 KB_SCIC KBSMI# DB7 A S-RB551V-30_SOD323 KB_SMIC TP2 TP3 25 29,30 29 25 22 16 RB15 RNB1 1 3 5 7 B PWR_SWAC_INBAT_IN- PWR_SWAC_INBAT_IN- BT_WLAN_K- BT_WLAN_KCIR_DATA 49 50 51 52 53 56 57 58 59 60 61 64 65 66 67 68 153 154 2 26 29 30 44 76 172 176 TP28 LID- LID- 71 72 73 74 77 78 79 80 POWER & GND VCCA AGND SERIRQ LFRAME# LAD0 LAD1 LPC LAD2 LAD3 LCLK CLKRUN#/GPIO0C TP21 TP20 8P4R-10KR0402 391P81 2 VBAT 4 ICHG 6 INP 8 100KR0402 PRE_CHG RT6 100KR0402 ENCHG R23 100KR0402 RSMRST# 25 SEARCH/CAMERA_K31 +3VSUSPWROK TP4 TP15 30 PRE_CHG 29,30 ENCHG 25 WLAN_PWRON 29 AC_CT L 19 PM_SLP_S4# 19 PM_SLP_S5# 30 ENCHG_1P +5VRUN RB13 RT5 RB19 10KR0402 X_0R0402RUN_KBC KB_SMIPRE_CHG ENCHG WLAN_PWRON AC_CT L 0R0402 3 THERMAL_INT# 3,19 RSMRST# 31 SUS_ON 25 CAP_SENSOR_INT RSMRST# SUS_ON MAIL_KKB_PWRBT- TP7 TP_DATA TP_CLK TP_DATA TP_CLK C T 14 ENCHG_1P ENCHG_2P ENCHG_3P TP16 TP17 X_0R0402 RT3 RB18 391P81 VBAT ICHG INP NB_THRM_ALERTLM86_THRM_ALERT3910P89 3910P90 SEARCH/CAMERA_K+3VSUSPWROK 3G_TV_SWIE_KHW_STRAP_11 HW_STRAP_12 TP36 TP35 19 PM_SLP_S3# 31,32,33 RUN_ON 10KR0402 110 111 114 115 116 117 TP_CLK TP_DATA 8P4R-10KR0402 NB_THRM_ALERT2 LM86_THRM_ALERT4 3910P89 6 3910P90 8 RB16 TP_CLK1 TP_DATA1 81 82 83 84 87 88 89 90 28 27 175 8 11 12 20 21 22 48 62 63 69 70 75 109 118 119 148 149 155 156 162 168 XIO8CS#/GPIO18 XIO9CS#/GPIO19 XIOACS#/GPIO1A XIOBCS#/GPIO1B XIOCCS#/GPIO1C XIODCS#/GPIO1D XIOECS#/GPIO1E XIOFCS#/GPIO1F A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20/GPIO23 GPIO0B LRST#/GPIO2C KBRST#/GPIO03 GA20/GPIO02 ECSCI# ECRST# KSI0/GPIK0 KSI1/GPIK1 KSI2/GPIK2 KSI3/GPIK3 KSI4/GPIK4 KSI5/GPIK5 KSI6/GPIK6 KSI7/GPIK7 KSO0/GPOK0 KSO1/GPOK1 KSO2/GPOK2 KSO3/GPOK3 KSO4/GPOK4 KSO5/GPOK5 KSO6/GPOK6 KSO7/GPOK7 KSO8/GPOK8 KSO9/GPOK9 KSO10/GPOK10 KSO11/GPOK11 KSO12/GPOK12 KSO13/GPOK13 KSO14/GPOK14 KSO15/GPOK15 KSO16/GPOK16 KSO17/GPOK17 X-BUS KBC GPWU0 GPWU1 GPWU2 GPWU3 GPWU4 GPWU5 GPWU6/TIN1 GPWU7/TIN2/FANFB2 EC_CLKRUN# 10KR0402 RNB2 1 3 5 7 KBOUT 0 KBOUT 1 KBOUT 2 KBOUT 3 KBOUT 4 KBOUT 5 KBOUT 6 KBOUT 7 KBOUT 8 KBOUT 9 KBOUT10 KBOUT11 KBOUT12 KBOUT13 KBOUT14 KBOUT15 S-RB551V-30_SOD323 EC_A20GATE C DB1 PM_PWRBTN# A C KBIN0 KBIN1 KBIN2 KBIN3 KBIN4 KBIN5 KBIN6 KBIN7 A S-BAS40WS_SOD323-RH CB3 DB3 A KBRST# KBRST# 10KR0402 DB4 C 24 165 6 5 31 19 LPC_RST# KB_RESETEC_A20GATE KB_SCIEC_RST- 18,26 LPC_RST# +3VALW 7 9 15 14 13 10 18 25 VCC VCC VCC VCC VCC VCC VCC PSCLK1 PSDAT1 PSCLK2 PSDAT2 PSCLK3 PSDAT3 PS2 I/F AD0/GPIAD0 AD1/GPIAD1 AD2/GPIAD2 AD3/GPIAD3 AD4/GPIAD4 AD5/GPIAD5 AD6/GPIAD6 AD7/GPIAD7 GPIO0E GPIO0D TOUT2/GPIO2F GPIO04 GPIO05/FAN3PWM GPIO06/FANFB3 GPIO07 GPIO08 GPIO09 GPIO10 GPIO13 GPIO14 GPIO15 GPIO16 GPIO17 GPIO24 GPIO25 GPIO26 GPIO27 GPIO28 GPIO29 GPIO2A GPIO2B GPIO2D D0 D1 D2 D3 D4 D5 D6 D7 RD# WR# IOCS# MEMCS# SCL1 SDA1 SCL2 SDA2 SM-BUS PWM0/GPOW0 PWM1/GPOW1 PWM2/GPOW2/FAN1PWM PWM3/GPOW3 PWM4/GPOW4 PWM5/GPOW5 PWM6/GPOW6 PWM7/GPOW7/FAN2PWM FANFB1/TOUT1/GPIO2E CAPLOCK#/GPIO11 FNLOCK#/GPIO12 SCROLLLOCK#/GPIO0F NUMLOCK#/GPIO0A DA0/GPODA0 DA1/GPODA1 DA2/GPODA2 DA3/GPODA3 DA4/GPODA4 DA5/GPODA5 DA6/GPODA6 DA7/GPODA7 E51IT0/GPIO00 E51IT1/GPIO01 E51RXD/GPIO21/ISPCLK E51TXD/GPIO22/ISPDAT E51CS#/GPIO20/ISPEN_TP CB2 CB5 C0.1U10X0402 R81 CB6 C0.1U10X0402 EC_VCCA EC_AGND U50 85 86 91 92 93 94 97 98 LED_BATLOWLED_CHARGE- LED_BATLOW- 25 LED_CHARGE- 25 LED_ACPIBLUETOOTH_LEDLED_WLANDUAL_CELL_SW- EC_A0 EC_A1 EC_A2 EC_A3 EC_A4 EC_A5 EC_A6 EC_A7 EC_A8 EC_A9 EC_A10 EC_A11 EC_A12 EC_A13 EC_A14 EC_A15 EC_A16 EC_A17 EC_A18 EC_A19 LED_ACPI- 25 BLUETOOTH_LED- 25 LED_WLAN- 25 DUAL_CELL_SW- 25 8/22 124 125 126 127 128 131 132 133 143 142 135 134 130 129 121 120 113 112 104 103 108 EC_A0 EC_A1 EC_A2 EC_A3 EC_A4 EC_A5 EC_A6 EC_A7 EC_A8 EC_A9 EC_A10 EC_A11 EC_A12 EC_A13 EC_A14 EC_A15 EC_A16 EC_A17 EC_A18 EC_A19 EC_A20 138 139 140 141 144 145 146 147 150 151 152 173 EC_D0 EC_D1 EC_D2 EC_D3 EC_D4 EC_D5 EC_D6 EC_D7 EC_RDEC_WREC_CSMEM_CS- UT1 TP26 TP23 EC_A0 EC_A1 EC_A2 EC_A3 EC_A4 EC_A5 EC_A6 EC_A7 EC_A8 EC_A9 EC_A10 EC_A11 EC_A12 EC_A13 EC_A14 EC_A15 EC_A16 EC_A17 12 11 10 9 8 7 6 5 27 26 23 25 4 28 29 3 2 30 MEM_CSEC_RDEC_WR- 22 24 31 A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 CE# OE# WE# D0 D1 D2 D3 D4 D5 D6 D7 VPP 13 14 15 17 18 19 20 21 EC_D0 EC_D1 EC_D2 EC_D3 EC_D4 EC_D5 EC_D6 EC_D7 1 EC_A18 VCC 9 24 22 EC_WREC_RDMEM_CS- +3VALW 30 31 23 39 CT44 CT43 X_C0.1U10X0402 X_C10U10Y0805 1/3 TP1 BATCLK_M BATDATA_M SMB_CPU_CLK SMB_CPU_DATA 32 33 36 37 38 39 40 43 CAMERA_ON- 171 BT_PWR_ONBAT_LOW_T ONE LED_CAPVR_ON LED_SCRLED_NUM- 99 100 101 102 1 42 47 174 BR-AD-ADJ FAN_DA1 3 4 106 107 105 CAMERA_ON- 22 3G_POWER_ON- 25 TP30 BT_PWR_ON- 22 TP148 TP31 TP32 TP34 FAN_TACH1 54 55 41 23 M31-3904078-W03 BATCLK_M 29 BATDATA_M 29 SMB_CPU_CLK 3 SMB_CPU_DATA 3 C +3VALW FAN_TACH1 26 LED_CAPVR_ON LED_SCRLED_NUM- 25 34 25 25 HW_STRAP_10 RB2 2.2KR0402 BATDATA_M RB1 2.2KR0402 EC_A4 RB6 470KR0402 EC_A5 RB4 470KR0402 HW_STRAP_10 RB14 470KR0402 EC_A1 RB8 470KR0402 HW_STRAP_11 RB9 470KR0402 HW_STRAP_12 RB10 470KR0402 C95 +3VRUN U3 X_S08P5X_SC70 TP24 TP22 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 100KR0402 ALLSYSPG R38 X_0R R39 0R R36 0R R37 0R R40 0R +3VRUN R178 X_4.7KR0402 X_C1000P50X0402 X_C1000P50X0402 2 25 CAP_SENSOR_CLK B R33 RB3 0R0402 158 EC_XIN CT7 C18P50N0402 CONN-FPC25B_white-RH N5A-25F0070-A10 FPC_S25 1 32 EC_XOUT 1 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 2 DIMM_ON R44 160 KBOUT 0 KBOUT 1 KBOUT 2 KBIN0 KBIN1 KBIN2 KBIN3 KBOUT 3 KBOUT 4 KBIN4 KBIN5 KBIN6 KBIN7 KBOUT 5 KBOUT 6 KBOUT 7 KBOUT 8 KBOUT 9 KBOUT10 KBOUT11 KBOUT12 KBOUT13 KBOUT14 KBOUT15 +3VSUS X_C0.1U10X0402 4 X_0R0402 CON3 H/W Strap for ENE 3910 BR-AD-ADJ 16 TP29 FAN1_PWM 26 TP27 TP13 TP33 TP37 TP6 EC_ALLSYSPG DIMM_KBC RB5 BATCLK_M +3VALW 32.768KHZ12.5P_S-RH-2 PM_SLP_S4# 10 11 12 29 38 BIOS1 163 164 169 170 D04-0300800-T16 H=0.785mm RB17 VCC VCC D CT5 CT4 X_C0.1U10X0402 C10U10Y0805 16 GND PLCC-32P_brown PM_SLP_S3# DIMM_ON WE# OE# CE# EC_D0 EC_D1 EC_D2 EC_D3 EC_D4 EC_D5 EC_D6 EC_D7 X_SST ( SST39VF080-70-4C-EI) 8M FOR PBA FUNCTION RT2 0R0402 NC NC NC NC NC 25 26 27 28 32 33 34 35 +3VALW 32 10MR1%0402 RB12 A0 A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 GND GND KB910QF-C1-LF RUN_ON 21 20 19 18 17 16 15 14 8 7 36 6 5 4 3 2 1 40 13 37 D0 D1 D2 D3 D4 D5 D6 D7 W39L040P-70Z-RH 22 22 C T 15 8/22 PN: FOR ROHS N/A CLOCKS XCLKI C10U10Y0805 0R 95 96 YT1 A CB4 C0.1U10X0402 EC_AGND X_100KR0402 XCLKO CB1 C0.1U10X0402 26 X_10KR0402 SIRQ LPC_FRAME# LAD0 LAD1 LAD2 LAD3 LPC_EC_CLK 19,23,26 SIRQ 17,26 LPC_FRAME# 17,26 LAD0 17,26 LAD1 17,26 LAD2 17,26 LAD3 15 LPC_EC_CLK VCCBAT GND GND GND GND GND GND BATGND 27 RT1 17 35 46 122 137 167 159 G FWH_ID0 D +3VALW For SW Debug LB1 1 2 80L700m_200 EC_VCCA 16 34 45 123 136 157 166 S +1_8VSUS_PWRGD 32 VTT_PWRGD 33 +1_5VRUN_PWRGD 33 +1_25VRUN_PWRGD 32 MPWROK 6,19 Q13 BATCLK_M D X_N-BSS138_NL_SOT23-LF +3VRUN CT6 C18P50N0402 8/22 0R0402 R177 X_4.7KR0402 25 CAP_SENSOR_DATA S G +5VRUN +3VRUN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 161 5 17 L_LDRQ0# 15 LPC_DEBUG 1 2 3 4 5 6 7 8 9 10 11 12 13 14 3 LPC_FRAME# LAD3 LAD2 LAD1 LAD0 L_LDRQ0# LPC_DEBUG SIRQ LPC_RST# 1 26 4 27 5 A Q14 BATDATA_M D X_N-BSS138_NL_SOT23-LF MSI CORPORATION Title KBC/EC/uP (ENE3910-LFQP176) Size Document Number Custom Date: 5 [email protected] GRATIS - FOR FREE 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 1 Sheet 21 of 41 3 2 +5VRUN +3VRUN +5VRUN SATA HDD 0R0402 D S 0R0402 N5A-12F0130-M06 FPC_SD54548_1211 18 USBP0P R419 0R0402 L30 X_CMC-L02-9008014-T34 USB5V_B 6 7 _BH1X5#S_white-1.25pitch-1 N32-1050150-H06 53261_05 USB5V_B F2 C230 EC3 2 C227 1 EC2 2 C220 2 2 F-SMD1812P150TF-RH 1 USB CONNECTOR +3VRUN PATA CDROM/DVD 1 2 3 4 5 USBP0N_R USBP0P_R CONN-FPC12U_white-RH L18 X_CMC-L02-9008014-T34 +5VRUN C444 C140 1 USBP6P_R USBP6N_R C423 USBP2N L37 CMC-L02-9008014-T34 X_C10P50N0402 18 C435 5 1 2 3 4 C436 USBP6N X_C10P50N0402 L40 CMC-L02-9008014-T34 X_C10P50N0402 X_C10P50N0402 CONN-USBX1_black-RH-4 N53-04M0411-A10 17 5 USB3 1 2 3 4 6 C424 1 2 3 4 6 2 18 IDE_PDD[15:0] USBP6P C 6 1 2 3 4 USBP2P_R USBP2N_R IDE_PDD[15:0] C470P50X0402 C470P50X0402 1 C470P50X0402 USB2 3 U17 S08P5X_SC70 18 3 1 USBP2P 3 LED_HDD- 18 C10U10Y0805 17 1 SATA_ACTIVE# CD_ACTIVE# 4 C100U6.3Y1210-RH 2 5 R209 X_10KR0402 2 C100U6.3Y1210-RH 2 R207 10KR0402 4 C190 C0.1U10X0402 C 1 C470P50X0402 +3VRUN +3VRUN 25 R418 USBP0N C334 R421 Close to CON. 18 C339 X_C10P50N0402 USBP4P D CON10 X_C10P50N0402 18 Active High 14 G1 G2 M1 M2 CONN-SATA4_black-RH N5N-22F0080-A10 SATA_CON_22P C19 C0.1U10X0402 TP_DATA TP_CLK 14 G 21 CAMERA_ON- 13 1 GND GND GND GND GND S7 RX 21 21 13 C0.01U25X0402 Q6 N-2N7002_SOT23 SOT23SGD_T 1 S6 USBP4N_R USBP4P_R 1 2 3 4 5 6 7 8 9 10 11 12 1 SATA0RXP 0R0402 C51 C22U6.3X50805-RH 2 17 RX# R420 USBP4N 10KR0402 4 SATA0RXN GND 18 1 2 3 4 5 6 7 8 9 10 11 12 R69 5 17 S5 +5VRUN C52 +3VRUN CN1 C0.1U10X0402 5 S4 TX# _P-NDS352AP_SOT23 6 S3 +3V_CAMERA Q8 C136 C10U10Y0805 1 SATA0TXN P1 P2 P3 P4 P5 P6 P7 P8 P9 P10 P11 P12 P13 P14 P15 CAMERA +3VRUN 2 17 TX V33 V33 V33 GND GND GND V5 V5 V5 GND Reserved GND V12 V12 V12 C139 C0.1U10X0402 4 SATA0TXP GND Power Segment D 17 S2 Signal Segment S1 C123 C10U10Y0805 3 CON11 C22 C0.1U10X0402 8/22 FINGERPRINT & TOUCH PAD 2 C117 C36 C100U6.3Y1210-RH 1 4 4 3 5 CONN-USBX1_black-RH-4 N53-04M0411-A10 C394 C404 USBP7P +5VRUN R423 R417 0R0402 L39 X_CMC-L02-9008014-T34 5 18 10KR0402 8/22 G 21 BT_PWR_ON- C0.01U25X0402 Active High 2 1 3 2 1 C470P50X0402 2 USBP5P 4 1 _BH1X8S_white-1.25pitch Q33 N32-1080060-H06 N-2N7002_SOT23 53398_08 SOT23SGD_T 1 2 3 4 USBP5P_R USBP5N_R 18 R374 C100U6.3Y1210-RH DB9 X_ESD-IP4220 C137 USB1 1 2 3 4 C138 USBP5N L19 CMC-L02-9008014-T34 1KR0402 B 5 18 6 USBP5N 5 IDE_PDA2 17 IDE_PDCS3# 17 25 CHANNEL_CLK 25 CHANNEL_DATA USBP5P C127 C100U6.3Y1210-RH 2 17 EC1 1 USBP7N_R USBP7P_R 1 0R0402 4 IDE_PDDACK# R422 C470P50X0402 +5VRUN USBP7N C126 1 2 3 4 5 6 7 8 6 C397 F-SMD1812P150TF-RH CN6 +5VRUN C0.1U10X0402 C0.1U10X0402 1 C226 6 X_1KR0402 CD_SEL F1 BLUETOOTH IDE_PDDREQ 17 18 IDE_PDIOR# 17 USB5V_A 2 R372 IDE_PATADET IDE_PDA2 IDE_PDCS3# +5VRUN 3 +5VRUN IDE_PDDACK# USB5V_A 27 D +5VRUN CD_R IDE_PDD8 IDE_PDD9 IDE_PDD10 IDE_PDD11 IDE_PDD12 IDE_PDD13 IDE_PDD14 IDE_PDD15 IDE_PDDREQ IDE_PDIOR# S IDE_PDIOW# IDE_PIORDY INT_IRQ14 IDE_PDA1 IDE_PDA0 IDE_PDCS1# CD_R 2 17 17 17 17 17 17 IDE_PDIOW# IDE_PIORDY INT_IRQ14 IDE_PDA1 IDE_PDA0 IDE_PDCS1# CD_ACTIVE# 51 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 4 B 47R 1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 3 CD_L CDGND IDE1_RST# R361 IDE_PDD7 IDE_PDD6 IDE_PDD5 IDE_PDD4 IDE_PDD3 IDE_PDD2 IDE_PDD1 IDE_PDD0 CD_L CDGND IDE1_RST# 54 27 27 18 53 CN5 X_C10P50N0402 X_C10P50N0402 CONN-USBX1_black-RH-4 N53-04M0411-A10 CIR CONN-BTB50M#_lime/DIP-NB A PIN32:PDIAG PIN37:PASP PIN47:CABLE SELECT Low:Master NC or High:Slave +5VRUN N5C-50M0111-A10 CDROM50_AMP_1470277_1 +5VRUN +3VRUN INT_IRQ14 R370 8.2KR0402 R290 IDE_PIORDY R369 4.7KR0402 22R0402 IDE_PATADET R371 470KR0402 U23 3 C316 IDE_PDDREQ R368 X_100KR0402 2 A R283 10KR0402 VDD DATA GND GND C10U10Y0805 4 1 CIR_DATA 21 C309 MSI CORPORATION X_C22P50N0402-1 Title TSOP6238-TR D0B-0623800-V02 IR_Reciver_4P HDD,CDROM,CIR,USB CONN. Size Document Number Custom Date: 5 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 22 of 41 5 4 3 2 1 Close to chip +3VSUS_SOCKET SDDAT1 47KR0402 2 4 6 8 SDDAT2 SDDAT3 SDCMD SDDAT0 GRST# should connect to Power On reset if support S3 +3VSUS_SOCKET SUSPEND# 8P4R-47KR0402 RN17 1 2 3 4 5 6 7 8 MSBS Close to chip MMDAT6 MMDAT5 MS_CLK R49 22R0402 MSDATA1 MSDATA0 MSDATA2 MSDATA3 MSCLK 0R0402 CARD_RST# TP5 TP12 X_0R0402 R12 R11 8.2KR0402 SMCD# 47KR0402 MSINS# U4 MSDATA1 MSDATA0 MSDATA2 MSDATA3 8P4R-47KR0402 C Close to chip SD_CLK R65 SDDAT2 SDDAT3 SDCMD 22R0402 SDCLK SDDAT0 SDDAT1 +3VSUS_SOCKET 18 18 PCI_REQ#0 PCI_GNT#0 PCI_AD31 PCI_AD30 PCI_AD29 PCI_AD[31:0] PCI_AD28 PCI_AD27 PCI_AD26 PCI_AD25 PCI_AD24 18 PCI_AD20 R61 PCI_CBE#3 100R0402 IDSEL +3VCC XSDPWR33OZ NC GND_SD SDDAT2SMCLE SDDAT3SMDAT4 SDCMDSMALE SDCLKSMWEOZ SDDAT0SMDAT7 SDDAT1SMDAT0 VCC_SD NC NC NC NC NC PCIREQOZ PCIGNTIZ PCIAD31 PCIAD30 PCIAD29 VSS PCIAD28 PCIAD27 PCIAD26 PCIAD25 PCIAD24 PCICBE3Z PCIIDSELI VCC NC NC NC MFUNC6 R30 X_0R0402 P_CLKRUN# 19,26 MFUNC3 R27 0R0402 SIRQ 19,21,26 R14 X_0R0805 R13 0R0805 Q1 R6 47KR0402 MR510-A-RH MSBSOSMDAT1 MS_SMPWROZ MFUNC0 RIOUTZ_PMEOZ VSS PCIAD0 MSINSIZ SMCDIZ PCIAD1 PCIAD2 PCIAD3 PCIAD4 PCIAD5 PCIAD6 PCIAD7 VCC VSS NC NC NC NC NC PCICBE0Z PCIAD8 PCIAD9 PCIAD10 PCIAD11 VCC PCIAD12 PCIAD13 PCIAD14 PCIAD15 96 95 94 93 92 91 90 89 88 87 86 85 84 83 82 81 80 79 78 77 76 75 74 73 72 71 70 69 68 67 66 65 MSBS MSPWREN# MFUNC0 R9 0R0402 INT_PIRQA# 18 47KR0402 +3VCC PCI_PME# R10 18 PCI_AD0 MSINS# SMCD# PCI_AD1 PCI_AD2 PCI_AD3 PCI_AD4 PCI_AD5 PCI_AD6 PCI_AD7 C9 C10U10Y0805 R7 0R0402 Close to socket C457 C10U10Y0805 J18 SDCD# SDDAT1 SDDAT0 SD_CLK PCI_AD12 PCI_AD13 PCI_AD14 PCI_AD15 C454 C0.1U10X0402 C MSPWREN# +3VCC PCI_AD8 PCI_AD9 PCI_AD10 PCI_AD11 _P-NDS352AP_SOT23 SDPWREN33# PCI_CBE#0 +3VCC 18 SDCMD SDDAT3 SDDAT2 SDWP Close to socket 1 3 5 7 9 11 13 15 17 19 26 25 27 28 CD_SW SD_DAT1 SD_DAT0 SD_VSS SD_CLK SD_VDD SD_VSS SD_CMD SD_CD/SD_DAT3 SD_DAT2 SD_WP MS_VSS MS_BS MS_DAT1 MS_SDIO/DAT0 MS_DAT2 MS_INS MS_DAT3 MS_SCLK MS_VCC MS_VSS GND GND GND GND GND NP1 NP2 2 4 6 8 10 12 14 16 18 20 MSBS MSDATA1 MSDATA0 MSDATA2 MSINS# MSDATA3 MS_CLK 21 22 23 24 Close to socket B CONN-SD_MMC_MS CARD-RH-1 N58-20F0300-N40 MMC_MS_26P Close to socket 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 B 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 +3VSUS_SOCKET PCIAD23 PCIAD22 PCIAD21 PCIAD20 PCIRSTIZ PCICLKI PCIAD19 PCIAD18 SDCLKI VCC VSS NC NC PCIAD17 PCIAD16 PCICBE2Z PCIFRAMEZ NC NC VCC PCIIRDYZ PCITRDYZ PCIDEVSELZ PCISTOPZ PCIPERRZ PCISERROZ PCIPAR PCICBE1Z VSS NC NC NC SDPWREN33# +3VRUN +3VCC NC XPMPWR_ENIZ XPMPWR_O XPMPWR_VCC NC NC XSDCDIZ XSDWPISMWPDIZ VCC VSS XMSCLKOSMREOZ XMSDAT3BSMDAT3B XMSDAT2BSMDAT5B XMSDAT0BSMDAT2B XMSDAT1BSMDAT6B VCC_SD XMDAT5BSMWPOZ XMDAT6BSMBSYIZ XMFUNC7B GND_SD XSUSPENDIZ XMFUNC6B XMFUNC5B XMFUNC4B XGRSTIZ XMFUNC3B XMFUNC2B VCC XMFUNC1B XMDAT4B XMDAT7BSMCEOZ VSS RN14 2 4 6 8 +3VSUS C10P50N0402 47KR0402 47KR0402 128 127 126 125 124 123 122 121 120 119 118 117 116 115 114 113 112 111 110 109 108 107 106 105 104 103 102 101 100 99 98 97 SDCD# SDWP R55 R50 C10P50N0402 X_0R0805 SDCD# SDWP R57 C459 +3VSUS_SOCKET R60 TP9 +3VCC C469 +3VCC GRST# MFUNC3 MFUNC2 MMDAT7 MMDAT4 +3VCC 18 PCI_AD[31:0] R28 +3VCC 8P4R-47KR0402 1 3 5 7 D SUSPEND# MFUNC6 MFUNC5 D 8P4R-47KR0402 RN16 1 2 3 4 5 6 7 8 MMDAT5 MMDAT6 MFUNC7 +3VCC MMDAT4 MMDAT7 R67 RN15 1 3 5 7 +3VCC PCI_AD17 PCI_AD16 SDCD# SDDAT1 MSBS SDDAT0 CN9 7 5 3 1 X_8P4C-10P50N 8 6 4 2 MSDATA1 MSDATA0 MSDATA2 MSINS# CN8 7 5 3 1 X_8P4C-10P50N 8 6 4 2 MSDATA3 SDCMD SDDAT3 SDDAT2 CN7 7 5 3 1 X_8P4C-10P50N 8 6 4 2 SDWP C472 X_C10P50N0402 Y1 4 C12 VDD NC GND OUT 18 CARD_RST# 15 PCLK_CARD 1 R48 2 3 SDCLKI_R SDCLKI D05-2200100-K21 H=1.4mm C24 X_22R0402 X_OSC-50MHZ50_S X_C10P50N0402 X_C0.1U10X0402 PCI_AD19 PCI_AD18 SDCLKI PCI_AD23 PCI_AD22 PCI_AD21 PCI_AD20 For EMI reserve +3VCC +3VCC 18 PCI_CBE#2 18 PCI_FRAME# 18 PCI_IRDY# 18 PCI_TRDY# 18 PCI_DEVSEL# 18 PCI_STOP# 18 PCI_PERR# 18 PCI_SERR# 18 PCI_PAR 18 PCI_CBE#1 A A +3VCC MSI CORPORATION CT11 CT2 CT8 CT13 CT10 CT3 CT12 CT1 CT9 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 Title Card Reader (MR510) Size Document Number Custom Date: 5 [email protected] GRATIS - FOR FREE 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 23 of 41 5 4 C90 C27P50N-1 3 2 1 X_IN AVDD33 Y3 25MHZ20P_S-2 C93 D04-1001100-T16 H=1.3mm C27P50N-1 C87 C0.1U10X0402 X_OUT GVDD VDD33 C99 C1U16Y D U24 C103 C0.1U10X0402 C82 C0.1U10X0402 RSET C0.01U25X0402 C365 C0.01U25X0402 C369 C0.01U25X0402 MDI1MDI1+ AVDD33 MDI0+ MDI0AVDD18 MDI1+ MDI1MDI2+ MDI2MDI3+ MDI3DVDD15 VDD33 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 VCTRL18 AVDD33 MDIP0 MDIN0 AVDD18 MDIP1 MDIN1 AVDD18 MDIP2 MDIN2 AVDD18 MDIP3 MDIN3 AVDD18 VDD15 VDD33 C TCT1 TD1+ TD1TCT2 TD2+ TD2TCT3 TD3+ TD3TCT4 TD4+ TD4- RN6 MCT1 MX1+ MX1MCT2 MX2+ MX2MCT3 MX3+ MX3MCT4 MX4+ MX4- 24 23 22 21 20 19 18 17 16 15 14 13 1 3 5 7 MCT1 TRD3TRD3+ MCT2 TRD2TRD2+ MCT3 TRD1TRD1+ MCT4 TRD0TRD0+ 2 4 6 8 D 8P4R-75R0402 48 47 46 45 44 43 42 41 40 39 38 37 36 35 34 33 EESK EEDI VDD33 EEDO EECS C48 +3VRUN C0.1U10X0402 VDD33 R78 1KR0402 ISOLATER85 C59 15KR0402 C C0.1U10X0402 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 C102 C0.1U10X0402 RTL8111B-GR-RH MDI0MDI0+ 1 2 3 4 5 6 7 8 9 10 11 12 GST5009 LF-RH EESK EEDI VDD33 EEDO EECS VDD15 NC VDD15 NC NC VDD15 VDD33 ISOLATEB NC NC VDD15 NC NC LANWAKEB PERSTB VDD15 EVDD18 HSIP HSIN EGND REFCLK_P REFCLK_N EVDD18 HSOP HSON EGND VDD15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 CTRL18 U10 RSET VCTRL15 GVDD CKTAL2 CKTAL1 AVDD33 VDD15 LED0 LED1 LED2 LED3 VDD33 VDD15 NC NC VDD15 PAD 65 2.49KR1%0402 EVDD18 LAN_PEN1 LAN_PEP1 18 C356 MDI2MDI2+ R117 19,25,26 C0.01U25X0402 MDI3MDI3+ DVDD15 CTRL15 C105 C0.1U10X0402 C351 C72 C74 C0.1U10X0402 C0.1U10X0402 PCIE_GLAN_RXN PCIE_GLAN_RXP 18 18 PCIE_WAKE# CLK_PCIE_LANCLK_PCIE_LAN LAN_RST# 18 PCIE_GLAN_TXP 18 PCIE_GLAN_TXN CLK_PCIE_LANCLK_PCIE_LAN L10 300L700m_250_0805 CI60 C0.1U10X0402 CI58 C0.1U10X0402 CI48 C0.1U10X0402 15 15 CON13 R72 9 R73 X_10KR0402 VDD33 3.6KR0402 LAN_GND B EECS EESK EEDI EEDO Icc33=103mA 1 2 3 4 U7 CS SK DI DO VCC DC ORG GND 8 7 6 5 C61 N55-08F0250-A10 C0.1U10X0402 AT93C46-10SU-2.7-RH +3VSUS VDD33 300L700m_250_0805 LAN_RJ45_8P_SMT L8 C35 C31 C22U6.3X50805-RH C0.1U10X0402 B CONN-RJ45[B]_smd-RH AVDD33 L3 1 2 3 4 5 6 7 8 TRD3TRD3+ TRD1TRD2TRD2+ TRD1+ TRD0TRD0+ 10 LAN_GND VDD33 300L700m_250_0805 VDD33 AVDD18 3 VDD33 Q4 CTRL15 1 DVDD15 P-BCP69_SOT223 3 Icc15=367mA CTRL18 1 2 4 Q5 P-BCP69_SOT223 C107 C108 C109 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C55 C60 C58 2 4 C22U6.3X50805-RH C0.1U10X0402 C56 C75 C96 C0.1U10X0402 C0.1U10X0402 C73 C68 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 Icc18=198mA A C44 A C38 EVDD18 C10U10Y0805 C0.1U10X0402 R91 C81 0R0805 C4.7U10Y0805 MSI CORPORATION C92 C0.1U10X0402 Title PCIE LAN ( RTL 8111B ) Size LAN_GND Date: 5 4 Document Number Custom 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 24 of 41 5 4 3 1 3 5 7 9 11 13 15 15 CLK_MINI0_PC IE15 CLK_MINI0_PCIE D pin23,25==> Tx pin31,33==> Rx Library is changed. 9/12 WAKE# RSVD1 RSVD2 CLKREQ# GND1 REFCLKREFCLK+ GND2 2 4 6 8 10 12 14 16 +3.3V_1 GND7 +1.5V_1 RSVD13 RSVD14 RSVD15 RSVD16 RSVD17 LED5 WLAN CARD +1_5VRUN +5VRUN 18 PCIE_MINI0_RXN 18 PCIE_MINI0_RXP 18 PCIE_MINI0_TXN 18 PCIE_MINI0_TXP 53 55 56 RSVD3 RSVD4 GND3 PET_N0 PET_P0 GND4 GND5 PER_N0 PER_P0 GND6 RSVD5 RSVD6 RSVD7 RSVD8 RSVD9 RSVD10 RSVD11 RSVD12 C4 1 220R C25 C10U10Y0805 2 BLUETOOTH_LED- 21 LED6 +5VRUN C0.1U10X0402 R292 220R 1 2 LED_WLAN- 21 LED-G_20125 LED7 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 GND8 RSVD18 PERST# +3.3_AUX GND9 +1.5V_2 SMB_CLK SMB_DATA GND10 USB_DUSB_D+ GND11 LED_WWAN# LED_WLAN# LED_WPAN# +1.5V_3 GND12 +3.3V_2 +5VALW Active High WLAN_PWRON 21 MINIPCIE0_RST# 18 +3VSUS R416 220R 2 1 R415 220R 4 3 C11 SUS_SMBCLK 19,26 SUS_SMBDATA 19,26 USBP1N USBP1P C2.2U6.3Y LED_BATLOW- 21 LED8 +5VSUS R414 1 220R 18 18 2 LED_ACPI- ON : Normal ( Power ON ) OFF : S4/S5 state Flash : S3 state +3VRUN C6 C10U10Y0805 21 +5VRUN LED-O_20125 C7 D LED_CHARGE- 21 LED-GO_3025-RH +5VALW C313 C315 C2.2U6.3Y C2.2U6.3Y LED4 54 GNDM2 GNDM1 R293 LED-B_20125-RH-1 KEY 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 1 +3VRUN CON12 19,24,26 PCIE_WAKE# 22 CHANNEL_DATA 22 CHANNEL_CLK 2 C0.1U10X0402 +5VRUN R294 220R 1 NC1 NC2 2 LED_HDD- 22 LED_NUM- 21 LED_CAP- 21 LED_SCR- 21 LED-O_20125 SLOT-PCI52P_black-0.8pitch-RH LED3 C +5VRUN N11-0520020-SH4 MINI_PCI_SMT_52P R3 220R 1 2 C LED-O_20125 LED2 +5VRUN TV TUNER /3G CARD 1 3 5 7 9 11 13 15 15 CLK_MINI1_PC IE15 CLK_MINI1_PCIE pin23,25==> Tx pin31,33==> Rx Library is changed. 9/12 B 220R WAKE# RSVD1 RSVD2 CLKREQ# GND1 REFCLKREFCLK+ GND2 +3.3V_1 GND7 +1.5V_1 RSVD13 RSVD14 RSVD15 RSVD16 RSVD17 2 4 6 8 10 12 14 16 18 PCIE_MINI1_RXN 18 PCIE_MINI1_RXP 18 PCIE_MINI1_TXN 18 PCIE_MINI1_TXP +3VRUN R231 0R0402 For 3G module 53 55 56 RSVD3 RSVD4 GND3 PET_N0 PET_P0 GND4 GND5 PER_N0 PER_P0 GND6 RSVD5 RSVD6 RSVD7 RSVD8 RSVD9 RSVD10 RSVD11 RSVD12 GNDM1 GND8 RSVD18 PERST# +3.3_AUX GND9 +1.5V_2 SMB_CLK SMB_DATA GND10 USB_DUSB_D+ GND11 LED_WWAN# LED_WLAN# LED_WPAN# +1.5V_3 GND12 +3.3V_2 GNDM2 2 LED-O_20125 LED1 +5VRUN +1_5VRUN R1 220R 1 2 LED-O_20125 CON2 USIM_PWR USIM_DATA USIM_CLK USIM_RESET C455 C446 C10U10Y0805 C0.1U10X0402 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 21 21 21 21 Active High 3G_POWER_ON- 21 MINIPCIE1_RST# 18 +3VSUS USBP3N USBP3P BT_WLAN_KSEARCH/CAMER A_KDUAL_CELL_SWPWR_SW- LED_ACPI - 21 CAP_SENSOR _CLK 21 CAP_SENSOR_DATA 21 CAP_SENSOR_INT C447 SUS_SMBCLK 19,26 SUS_SMBDATA 19,26 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 +3VRUN KEY 17 19 21 23 25 27 29 31 33 35 37 39 41 43 45 47 49 51 1 +3VRUN CON17 19,24,26 PCIE_WAKE# R2 C2.2U6.3Y LED_NUMLED_CAPLED_SCR- 18 18 +5VSUS +5VRUN +3VALW +3VRUN 21 22 B CONN-FPC20U N5A-20F0140-A81 FPC_S20 C239 C456 C441 C144 C143 C142 C141 54 C10U10Y0805 X_C22U6.3X50805-RH NC1 NC2 C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 N11-0520020-SH4 MINI_PCI_SMT_52P USIM_PWR A USIM_RESET USIM_DATA USIM_CLK CD C1 C5 C2 C6 C3 C7 C0.1U10X0402 For EMI reserve J20 SLOT-PCI52P_black-0.8pitch-RH C0.1U10X0402 CN2 7 PWR_SW5 DUAL_CELL_SWSEARCH/CAMERA_K-3 1 BT_WLAN_K- 1 X_8P4C-10P50N 8 6 4 2 A 2 MSI CORPORATION X_CONN-FPC14U _ SIMCARD7 Title AGND MINI_PCIE, LED, SW Size For ESD request Custom Date: 5 [email protected] GRATIS - FOR FREE 4 3 Document Number 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 25 of 41 5 4 3 2 1 CON4 +3VRUN UB2 +3VSUS R388 X_10KR0402 3 4 D 5 6 +3VRUN 7 8 +3VRUN_CARD NEWCARD_PERST- 9 10 11 12 SMDATAI SYSRST# 23 OC# SHDN# 3.3VAUX_IN STBY# CLKEN 3.3VIN 3.3VAUX_OUT 3.3VIN 1.5VIN 3.3VOUT 1.5VIN 3.3VOUT 1.5VOUT PERST# 1.5VOUT NC +3VSUS CLKEN 22 15 18 PCIE_NEWCARD_RXP 18 PCIE_NEWCARD_RXN Q29 N-2N7002_SOT23 SOT23SGD_T G 20 15 CLK_NEW_CARD 15 CLK_NEW_CARD- +3VSUS_CARD TP147 +3VRUN_CARD 19 CLK_NEW_CARD CLK_NEW_CARDCPPENEWCARD_CLKREQ- NEWCARD_PERST18 +1_5VRUN +3VSUS_CARD 19,24,25 PCIE_WAKE# 17 +1_5VRUN_CARD 15 CPPE- R392 +3VSUS X_100KR0402 14 CPUSB- R391 X_100KR0402 19,25 SUS_SMBDATA 19,25 SUS_SMBCLK TPB1 TPB2 SUS_SMBDATA SUS_SMBCLK CONN_TP2 CONN_TP3 CPUSB18 18 13 SMCLKO PCIE_WAKE# +1_5VRUN_CARD 16 CPUSB# SMCLKI CLK_NEW_CARD_EN- 21 CPPE# GND 18 PCIE_NEWCARD_TXP 18 PCIE_NEWCARD_TXN 10KR0402 24 SMDATAO D 2 18 NEWCARD_RST# R387 S 1 28 30 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 USBP9P USBP9N +3VSUS_CARD +3VRUN C452 +3VRUN_CARD +1_5VRUN_CARD D CARDBUS-26P-RH-2 CARDBUS_S26 N5D-26F0060-SH4 +1_5VRUN C442 C0.1U10X0402 NEW CARD 31 1 29 27 _P2231-099_SSOP24 SSOP24 +3VSUS 32 C458 C255 C445 C0.1U10X0402 C2.2U6.3Y C2.2U6.3Y C453 C0.1U10X0402 C0.1U10X0402 C C CPU FAN MDC_HDA_RST- TP146 TP145 +3VSUS Q25 U1 21 MDC_HDA_BIT_CLK MDC_HDA_BIT_CLK FAN1_PWM C2 17 1 + 3 - LM321MFX 4 +3VRUN 2 2 4 6 8 10 12 1 2 5 6 RESERVED1 RESERVED2 3.3Vmain/aux GND GND AZALIA_BCLK GND GND GND GND 17 MDC_HDA_RST# GND AZALIA_SDO GND AZALIA_SYNC AZALIA_SDI AZALIA_RST# R300 3 10KR0402 N-SI3456BDV-T1-E3_TSOP6-LF 2 C0.1U10X0402 31 32 33 34 C1 1 MDC_HDA_SYNC 17 MDC_HDA_SYNC +5VRUN N5C-12F0020-SH4 btb_con_a31793970_12P_H5MM 4 1 3 5 7 9 11 MDC_HDA_SDOUT 17 MDC_HDA_SDOUT PWR_SRC CONN-BTB12F_white-RH CON16 5 MDC Conn ector C47P50N0402 FAN_TACH1 VCCFAN1 R386 HDA_SDIN1 33R0402 2 17 21 CON8 HDA_SDIN1_MDC CB8 1 R305 2 100KR0402 VCCFAN1 C318 1 2 3 C319 R306 X_C10P50N0402 C10U10Y0805 C0.1U10X0402 100KR0402 +3VSUS CB9 C0.01U25X0402 BH1X3#S_white-1pitch-RH N32-1030660-H06 BHEADSMD1X3_90 1 B B CT42 C10U10Y0805 TPM 1.2 U14 26 23 20 17 22 17,21 LAD0 17,21 LAD1 17,21 LAD2 17,21 LAD3 17,21 LPC_FRAME# 19,23 P_CLKRUN# 19,21,23 SIRQ 16 28 15 27 15 LPC_TPM_CLK 21 18,21 A LPC_RST# TPM_PD 9 8 7 R123 X_0R0402 2 1 LAD0 LAD1 LAD2 LAD3 LFRAME# LRESET# LPCPD# CLKRUN#/GPIO5 SERIRQ LCLK GPIO4 NC PP GPIO3 NC 3V_2 3V_3 NC GND3 NC GND2 GND1 NC NC GPIO2 GPIO1 NC VNC 6 +3VRUN 19 24 10 +3VRUN 5 18 25 11 4 R173 A 10KR0402 14 13 R169 12 3 19 0R0402 TPM_PD LPCPD# MSI CORPORATION Title ST19WP18-TPM-C B07-SD19W02-S10 NEWCARD, MDC, TPM, FAN +3VRUN Size Document Number Custom Date: 5 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 26 of 41 5 4 ADD5V 3 2 1 +5VRUN 28 10R0402 SPDIFO SPDIFO_R C464 C2.2U6.3Y X_10KR0402 AGND R248 17 CODEC_HDA_SDIN0 R246 PC_BEEP 1 10KR0402 CB7 C0.1U10X0402 CODEC_ACZ_SDIN0 33R0402 17 CODEC_HDA_SYNC 17 CODEC_HDA_RST# PC_BEEP X_C10P50N0402 12 SDATA_OUT BIT_CLK DVSS2 SDATA_IN DVDD2 SYNC RESET# C261 X_C1000P50X0402 13 1 8.2KR0402 AGND AGND C0.1U10X0402 C277 C0.1U10X0402 38 37 41 40 39 REALTEK ALC883 MIC2_VREFOUT_L LINE1_VREFOUT_L MIC1_VREFOUT_L PC_BEEP R247 C MIC1_VREFOUT_R LINE2_VREFOUT VREF SENSE A 2 SPKR C260 2 19 5 6 7 8 9 10 11 17 CODEC_HDA_SDOUT 17,36 CODEC_HDA_BITCLK C266 FRONT_OUT_R FRONT_OUT_L 36 35 34 SENSE B 33 DCVOL AVSS1 AVDD1 LINE1_L LINE1_R 28 SPEAKER_MUTE# DVDD1 GPIO0 GPIO1 DVSS1 AGND R284 ADD5V 10KR0402 32 31 MIC_VREFOUT_R 30 29 MIC2_VREFOUT_L 28 MIC_VREFOUT_L ED1 27 C487 C1000P50X0402 C273 C1000P50X0402 ESD-ECVAL100505E19300NBT-RH 1 2 AGND 03/21 For EMI 26 25 C306 ADD5V For EMI solution C310 C0.1U10X0402 C10U10Y0805 AGND C ALC883-LF-A2-RH 23 24 C0.01U25X0402 1 2 3 4 DEPOP_MUTE# SPEAKER_MUTE# G924-475T1Uf_SOT23-5-RH MIC1_L MIC1_R C465 FRONT_OUT_R FRONT_OUT_L 21 22 10KR0402 AVDD2 LINE1_VREFOUT_R R245 SURR_OUT_R JDREF SURR_OUT_L R243 CD_L CD_GND CD_R Power On/Down & S3 Line-out Jack IN 18 19 20 SPEAKER_MUTE# Normal keep High Normal keep High MIC2_L MIC2_R 1 2 3 DEPOP_MUTE# U20 Low (Mu te) 16 17 High (turn on) D AGND AGND VDD3V LINE2_L LINE2_R ISOLATION (ANALOG 5V) 20KR1%0402 ADD5V 14 15 AGND POWER GND D R266 48 47 46 45 44 43 42 5 R261 U30 SPDIFO SPDIFI / EAPD SIDE_SURR_R SIDE_SURR_L LFE_OUT CEN_OUT AVSS2 C0.1U10X0402 C10U10Y0805 C4700P25X0402 C0.1U10X0402 VIN C468 SHDN# C0.1U10X0402 C471 OUT C304 C284 BYP C305 4 Close to ALC883 AGND 28 VDD3V MIC_JD R249 20KR1%0402 R252 5.1KR1%0402 +3VRUN 28 L24 FRONT_JD 1 2 80L3_70_0805 C259 C258 C0.1U10X0402 C257 C10U10Y0805 C0.1U10X0402 To INT Speaker 36 LINE2_R 36 LINE2_L C271 28 LINEOUT_L_INT C274 28 LINEOUT_R_INT 36 INT_MIC POWER ISOLATION (CODEC 3V) MIC1_R C312 C4.7U10X50805-RH MIC_IN_R 28 MIC1_L C300 C4.7U10X50805-RH MIC_IN_L 28 CD_R_IN C294 C1U10X /R_CD_R R281 47KR0402 CD_GND C287 C1U10X /R_CDGND R273 47KR0402 CD_L_IN C285 C1U10X /R_CD_L R271 47KR0402 C1U10X LINE2_L C1U10X LINE2_R C278 C1U10X MIC2_L C281 C1U10X MIC2_R R280 R274 47KR0402 47KR0402 47KR0402 From Jack CD_R 22 CDGND 22 CD_L 22 R272 B B TONE & SPEAKER AGND PWR R270 1KR0402 For CD-ROM noise issue SYS_OFF D Q19 N-2N7002_SOT23 SOT23SGD_T 100KR0402 C282 C10U25X6S1206-RH G Q20 N-2N7002_SOT23 SOT23SGD_T D-S interchange S D G S DEPOP_MUTE# R255 R253 SYS_ON +5VALW R251 10KR0402 PWR 100KR0402 Q22 D FRONT_OUT_R D6 C A R256 10KR0402 G D5 A S 18 CODEC_RST# Q16 N-2N7002_SOT23 SOT23SGD_T +3VRUN 100KR0402 A R265 180KR0402 R244 D C264 C2.2U16Y0805 R267 S-BAS40WS_SOD323-RH PWR SPEAKER_MUTE# G 10KR0402 A MUTE 75R R288 75R D2 G2 S2 G1 S1 D1 Q21 S1 G1 S2 G2 D1 D2 LINEOUT_R 28 LINEOUT_L 28 NN-2N7002DW_SOT363-RH 28 SYS_OFF NN-2N7002DW_SOT363-RH D4 C SYS_ON S-BAS40WS_SOD323-RH Q15 N-2N7002_SOT23 SOT23SGD_T POWER ON/OFF/S3/S4 NOISE CONTROL A S PWR_SRC FRONT_OUT_L S-BAS40WS_SOD323-RH C R287 MSI CORPORATION Title AZALIA CODEC(ALC883) Close To Power Source Size Date: 5 [email protected] GRATIS - FOR FREE Document Number Cust om POWER ON/OFF/S3/S4 NOISE CONTROL 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 27 of 41 5 4 2 1 +5VRUN L41 +5V_AMP 1 2 80L3_70_0805 C467 C470 C10U10Y0805 C485 6 15 16 C466 C0.1U10X0402 C4700P25X0402 C0.1U10X0402 5 27 LINEOUT_L_INT 17 27 LINEOUT_R_INT AGND C483 C0.47U10X C484 RIN+ 7 LIN+ 9 RIN+ C0.47U10X LIN+ 10 BYPASS BYPASS +5V_AMP NC SHUTDOWN RIN+ 21 4 8 SPK_OUT_L+ SPK_OUT_L- CON6 R275 MIC_VREFOUT_R 12 19 MUTE_INTSPKR 21 300L300m_350 1 2 L28 /MIC_IN_R 4 3 6 27 MIC_IN_L 300L300m_350 1 2 L29 /MIC_IN_L 2 1 R282 MIC_VREFOUT_L 11 GND#11 13 GND 1 GND#1 20 GND#20 APA2031RI-TRL_TSSOP20-LF AGND R413 X_100KR0402 GAIN1 R409 100KR0402 R411 100KR0402 C302 C289 C288 AGND AGND X_100KR0402 GAIN0 C1000P50X0402 C1000P50X0402 AGND GAIN0 GAIN1 +3VRUN 11 9 8 7 10 6 5 1 0 21.6d B 1 1 4.3d B X X N-2N7002_SOT23 C479 1 27 LINEOUT_L 27 SPEAKER_MUTE# G C100U6.3PT 2 300L300m_350 EARPHONE_L C480 1 27 LINEOUT_R Q18 + Q17 G 15.6d B S 100KR0402 D 1 D 27 C100U6.3PT 2 1 R410 S FRONT_JD 2 L43 EARPHONE_R 2 L42 300L300m_350 C476 C475 C268 R405 22KR0402 22KR0402 C100P50N0402 C100P50N0402 C100P50N0402 C269 CONN-JACK_SPDIF9P-RH N58-09F0041-F02 SPDIF_MINI_JACK AGND SPDIF ON/OFF CONTROL AGND C 12 4 2 3 1 /EARPHONE_L /EARPHONE_R 1 N-2N7002_SOT23 FOR APA2031 27 SPDIFO GND VCC VIN C0.1U10X0402 0 (PINK) +3V_SPDIF + R250 GAIN0 GAIN1 10dB MIC Jack CON5 AGND 0 IOC-JACK-D08-S56 N54-06F0461-A10 AUDIO_JACK_6P_OB +3V_SPDIF PWR_SRC 0 C303 AGND C 6dB 8/23 2.2KR0402 C290 C301 D 5 MIC_JD MIC_IN_R BYPASS GAIN0 GAIN1 27 27 LIN+ Internal Speaker Amp R412 2.2KR0402 X_C1000P50X0402 GAIN0 GAIN1 7/14 AGND RIN+#17 SPK_OUT_R+ SPK_OUT_R- X_C1000P50X0402 2 3 LOUT+ LOUT- LIN- 18 14 X_C0.1U10X0402 C0.47U10X ROUT+ ROUT- X_C0.1U10X0402 C482 U32 PVDD#6 PVDD VDD 8 7 +5V_AMP D 3 SPDIF & LineOut Jack AGND AGND (BLACK) ADD5V R408 CE1 100KR0402 B D MUTE_INTSPKR G MUTE AGND B C481 X_C1U16Y S 27 Q32 N-2N7002_SOT23 SOT23SGD_T X_C0.1U10X0402 FRONT_JD (MUTE SPEAKER) AGND POWER ON/OFF/S3/S4 NOISE CONTROL CON15 1 2 3 4 5 SPK_OUT_RSPK_OUT_R+ SPK_OUT_L+ SPK_OUT_LC242 C238 C220P50N0402 C236 C220P50N0402 C220P50N0402 C220P50N0402 6 7 C235 _BH1X5#S_white-1.25pitch-1 N32-1050150-H06 53261_05 A A Internal Speaker Connector MSI CORPORATION Title Audio Amp. & Jacks Size Document Number Custom Date: 5 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 28 of 41 5 4 3 2 1 1: 2: 3: 4: 5: 6: +3VALW F or EMI, Bottom Side X_C2200P50X0402 1 2 3 PFL1 1 Diode : Is=4.2A 120L6_15_4532 2 X_C2200P50X0402 5 4 1 2 3 +DC_IN PC11 PC7 PQ7 100KR0402 P-AO4413_SOIC8 8 7 6 5 21 PC15 X_C0.1U50Y C0.47U25Y0805 PR16 240KR0402 PC32 PC31 C0.01U25X0402 C0.1U50Y 21 PC28 C10U25X6S1206-RH BATCLK_M BATDATA_M 21 PR21 BATCLK_M PR9 100R0402 BATDATA_M PR8 100R0402 CON7 PC8 PQ5 P-DTA114EKA_SOT23 47KR0402 S PR30 C 8/22 PC5 X_C10P50N0402 _Z-UDZ3.3B_SOD323-RH PQ10 N-2N7002_SOT23 G AC_CTL PC4 X_C0.1U25Y _Z-UDZ3.3B_SOD323-RH 21 +VBATA PD2 PD3 D C 1 2 3 4 5 6 BAT_IN- E B D DC_IN+ C PJ1 PR20 I=15A C PC150 N92-03M0131-A10 DCJACK_5 PWR-JACK3M_black-5.2pitch-NB A X_C0.1U50Y A PC149 4 D GND SMCLK SMDATA BT Thermal VBATA VBATA N93-06M0141-A10 PC14 PWR-6P_black-RH C0.1U25Y X_C10P50N0402 BAT_2MM_B21_103_T C 100KR0402 I=8A +3VALW PQ12A PP-AO4805_SO8-RH Diode : Is=2.6A C17 PR23 100KR0402 C1U16Y 7 8 SDC_IN+ 1 2 PR31 X_10KR0402 AC_OK 10KR0402 PR36 100KR0402 D D1 D2 PR35 PQ8 PQ13 X_N-2N7002_SOT23 G AC_IN- I=8A I=8A B Diode : Is=2.6A V_CHG Diode : Is=2.6A PQ12B PP-AO4805_SO8-RH 5 6 PWR_SRC 21,30 G2 S2 G1 S1 S NN-2N7002DW_SOT363-RH 3 PP-AO4805_SO8-RH 1 B Diode : Is=3A PQ6A PD4 7 8 A C PR38 10KR0402 PR37 C0.1U25Y +VBATA 2 4 ES3BB-13-F-RH PC30 100KR0402 I=8A 5 6 3 PWR_SRC CHG_BATT_N PP-AO4805_SO8-RH D Diode : Is=2.6A 4 PQ6B PQ15 PR40 G ENCHG 2KR0402 N-2N7002_SOT23 PR32 470KR0402 S 21,30 A A MSI CORPORATION Title Battery Select Size Document Number Custom Date: 5 [email protected] GRATIS - FOR FREE 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 29 of 41 5 4 3 2 1 Adapter= 90 W SDC_IN+ Adapter input voltage set 17.4 Voltage PR69 D D DC_IN+ 0.02R1%-RH PC62 PR92 PR93 MAX1772_ACIN 7.15KR1%0402 A 53.6KR1% PD8 S-RB751V-40_SOD323-RH PR62 4.7R PR63 4.7R MAX1772_LDO C C0.1U25Y C10U25X6S1206-RH PC66 C2200P50X0402 PC65 PC70 C1U25X0805 PC64 PC69 C0.47U25Y0805 C1U16Y PC75 C0.47U25Y0805 SDC_IN+ MAX1772_REF G2 S2 G1 S1 21 PRE_CHG 21 ENCHG_1P D2 PR111 1.54KR1%0402-LF D1 PR110 20.5KR1%0402-LF NN-2N7002DW_SOT363-RH 13 15 14 MAX1772_REFIN MAX1772_VCTL MAX1772_ICTL PR96 15KR1%0402-1 +3VALW 1 PR101 DCIN 26 DLOV 11 LX ACIN DLO 12 1 C S-RB751V-40_SOD323-RH PQ17 MAX1772_ICHG 10 MAX1772_IINP 28 MAX1772_CCV 7 MAX1772_CCI PR64 12KR0402 6 5 PGND 24 PR80 1 8 2 7 3 6 0R PL11 CH-15U3.6A-RH 23 4 5 RI12 X_2.2R 20 NN-SP8K10S_SOP8-RH ICHG CSIP CSIN IINP BATT CCV CCI CCS GND GND CSIP CSIN 19 18 PC90 PC93 PC78 PC83 C10U25X6S1206-RH C10U25X6S1206-RH C10U25X6S1206-RH CI89 X_C1000P50X0402 1R1% 1R1% X_C10U25X6S1206-RH 8 9 PC103 C0.1U25Y PC104 C0.1U25Y 3 4 PR112 PR113 PC102 C0.1U25Y 17 MAX1772EEI+_QSOP28-LF PU3 V_CHG PR108 0.05R1%XTRA-RH 21 ACOK CLS AC_IN- REF AC_IN- PC63 C0.1U25Y A C0.1U25Y DHI MAX1772_ACIN 80L6_30_0805 C15U25POS PD9 C 22 PC71 + PC89 C0.1U25Y PC86 PR98 10KR0402 PR87 12KR0402 16 2 25 REFIN VCTL ICTL 49.9KR1%0402 PC88 C0.1U25Y PC82 C2200P50X0402 C0.1U25Y CELLS LDO BST PR97 21,29 PC91 2 PR99 24.3KR1%0402 PR103 47.5KR1%0402 CSSP PR102 34KR1%0402 100KR1%0402 C 4S1P: Charge current set 1.5 Amp 4S2P: Charge current set 3 Amp Pre-charger: Charge current set 200mA PQ18 PR91 33R0402 CSSN 27 PL4 MAX1772_REF B PR84 10KR0402 B PC80 C0.01U25X0402 PC79 C0.01U25X0402 PC76 C1U16Y PC85 C1000P50X0402 +5VALW PR76 28.7KR1%0402-RH J T 1 X_NC EMI Solution PR116 10KR0402 PQ19 D D2 D1 PR74 20KR1%0402 PR65 42.2KR1%0402 MAX1772_ICTL NN-2N7002DW_SOT363-RH GPIO33 Q12 N-2N7002_SOT 23 SOT23SGD_T ENCHG-1P PRE_CHG X_0R0402 X_0R0402 X_0R0402 ENCHG X 1 1 Pre-charge 1 0 1 4S1P-Fast charge 0 0 1 4S2P-Fast charge X X 0 STOP CHARGE S ENCHG S1 G1 S2 G2 17 21,29 G SET Iin MAX = 4.2A Isource_max=Vcls/(20xRS1) Vcls=4.096(20K/(20K+28.7K))=1.682V Ichange=4.2A RI9 RI11 RI10 G P IO33 : DEFAULT=HIGH High =>65W A Low =>90W A MSI CORPORATION Title Battery Charger Size Document Number Custom Date: 5 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 1 Sheet 30 of 41 5 4 80L6_30_0805 PL1 2 1 +5VALW PR39 4.7R VIN PD5 3 PWR_SRC 3 PC18 C1U16Y S-RB717F_SOT323-RH SYS_PWR_SRC SYS_PWR_SRC PC34 C1U25X0805 D + PC151 PC27 PC26 PC13 PC22 C0.1U50Y C2200P50X0402 C0.1U50Y C2200P50X0402 2 C22U25-RH 2 1 1 D VREF2 0R0402 PR17 0R0402 8 7 6 5 4 3 2 1 PR22 PQ11 NN-SP8K10S_SOP8-RH 8 Current limit at 6A 7 +3VALW 2 PR33 4.7R 2 6 3 5 4 LL2 EN5 EN3 PGOOD2 EN2 VBST2 DRVH2 LL2 DRVL2 TPS51120RHBR_QFN32-RH SKIPSEL TONSEL PGOOD1 EN1 VBST1 DRVH1 LL1 DRVL1 SKIPSEL TONSEL 32 31 30 29 28 27 26 25 current limit 6A=(10uA*PR3009)/Rds_on(100C) PR3009~16.9K PQ3 NN-SP8K10S_SOP8-RH PR10 4.7R 1 8 2 7 Current limit at 6A PC10 C0.1U50Y LL1 3 6 4 5 +5VSUS PL6 CH-7U7.2A-RH G1 1 OUT5 2 GNDA 17 18 19 20 21 22 23 24 C0.1U10X0402 C 2 C220U6.3POS-1 VIN PR29 100KR0402 5 6 7 8 PR26 16.9KR1%0402 PC3 C0.1U10X0402 PQ4 3VLDO 4 3 2 1 +3VSUS PC19 C10U10Y0805 PC17 C10U10Y0805 +5VRUN +5VALW PC38 PC40 C4.7U10Y0805 21 SUS_ON PR15 2KR1%0402 1 2 PC9 X_C0.1U10X0402 VREF2 +5VALW PR24 240KR0402 PR43 RUND +3VALW +5VSUS +3VSUS 8/23 PR5 10KR0402 2 PD1 C PR6 10KR0402 D1 A S-BAS40WS_SOD323-RH +3VSUSPWROK PC2 C1U16Y B PR13 X_0R0402 21 PQ2 PR11 0R0402 PWR_SRC PR27 100KR0402 2 PWR_SRC 2 PWR_SRC PR7 100KR0402 PR2 33KR0402 1 1 PR25 33KR0402 RUND PR28 470KR0402 PQ9 SUS_ON S1 G1 S2 G2 S1 G1 S2 G2 21 PC1 C0.1U25X NN-2N7002DW_SOT363-RH 8/23 14 PR1 470KR0402 PQ1 PC21 C0.1U25X RUND D2 D1 D2 D1 SUSD NN-2N7002DW_SOT363-RH S1 G1 S2 G2 NN-2N7002DW_SOT363-RH PWR_SRC PR12 X_0R0402 TONSEL SKIPSEL 2 PR4 51KR1% SUS_ON PC16 C1000P50X0402 1 1 PC37 C0.1U25X D2 1 10KR0402 A RUND N-AO4422_SOIC8 CI22 X_C1000P50X0402 +3VRUN C4.7U10Y0805 PC20 C1U16Y PR19 4.7R 4 RI1 X_2.2R 3 2 1 CI32 X_C1000P50X0402 C PR18 16.9KR1%0402 RI2 X_2.2R SUSD B C220U6.3POS-1 C10U10Y0805 Rds(on)Max24mR(25C) PR14 100KR0402 V5FILT NN-APM7313KC-TRL_SO8 PQ14 2 + PC6 PC12 8 7 6 5 33 PC23 2 + PC29 PGND2 CS2 VREG3 V5FILT VREG5 VIN CS1 PGND1 1 1 1 PL7 CH-7U7.2A-RH 9 10 11 12 13 14 15 16 1 PC24 C0.1U50Y G2 PU1 VO2 COMP2 VFB2 GND VREF2 VFB1 COMP1 VO1 current limit 6A=(10uA*PR3008)/Rds_on PR3009~16.9K (100C) A 8/23 21,32,33 RUN_ON PR34 100KR0402 MSI CORPORATION PR3 100KR0402 Title SYSTEM POWER 3/5V Size Document Number Custom Date: 5 [email protected] GRATIS - FOR FREE 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 31 of 41 5 4 3 2 1 +5VSUS PR180 10R VCCA_VDDQ PC178 C1U16Y PC140 C4.7U10Y0805 D D PU7 VDDP1 VCCA 20 8 REF_VDDQ EN/PSV TON REF PR184 9 10R0402 PWR_SRC 21 PWR_SRC_VDDQ 2 PR179 750KR0402 PC173 C1000P50X0402 PWR_SRC_VDDQ PC137 24 PR161 0R0402 PC139 C0.1U50Y COMP PC176 DH 23 DH_VDDQ PR163 10 PC177 VTTS LX 22 0R PC143 C0.1U50Y 15 14 PC142 VTT VTT DL C10U10Y0805 PGND2 6.2KR1%0402 19 PR181 0R0402 11 PQ33 + + PC134 C0.1U50Y 1 2 C PC135 X_C220U2.5SP-LF RI15 X_2.2R 3 C1U16Y PR164 CI155 X_C1000P50X0402 Current limit at 8A for +1.8VSUS 10R0402 Rds(on)Max6.2mR(25C) PGOOD TP102 VTTEN FB 6 FB_VDDQ 1 PR185 2 10KR1%0402 Current limit 8A=(10uA*PR143)/Rds_on(100C) PR3009~6.2K 2 21,31,33 RUN_ON VDDQ 16 PC144 7 21 +1_8VSUS_PWRGD 4 DL_VDDQ PR183 100KR0402 VDDQS PC136 _C330U2.5POS-2 21 N-AO4410_SOIC8 +3VSUS PC141 C10U10Y0805 G6 2 PC148 C10U10Y0805 2 +1_8VDIMM PL14 _CH-1.5U10A-RH 1 2 3 1 ILIM C15U25POS 5 6 7 8 PR162 G7 C0.1U50Y N-AO4422_SOIC8 C0.1U50Y SMDDR_VTERM C2200P50X0402 LX_VDDQ C + PC174 PC172 PQ32 1 80L6_30_0805 4 C0.1U50Y PC147 C1U16Y SMDDR_VTERM 2 1 2 3 TP103 DIMM_ON PL5 VSSA BST PR165 10R0402 0R0402 1 PGND2 1 TP104 PR178 GND 2 4 18 1 17 PGND1 1 25 C1U16Y VDDP2 5 6 7 8 PC175 C10U10Y0805 C10U10Y0805 Current limit at 3.8A for SMDDR_VTERM PC145 PD13 S-RB751V-40_SOD323-RH C1U16Y C 12 PC146 VDDP2 A PC138 13 2 5 VDDQ SC486IMLTRT_MLPQ24 PC179 C39P50N0402 PR186 FB=1.5V PR182 X_100KR0402 1 49.9KR1%0402 B B +5VRUN +3VRUN PC132 +1_8VDIMM X_100KR0402 PU6 VIN VIN#9 7 21 +1_25VRUN_PWRGD VCNTL PR160 X_100KR0402 6 2 PR159 1 1 2 C1U16Y 8 5 PC131 C22U6.3X50805-RH 9 1 VOUT EN VOUT#3 2 4 3 PR158 36KR1%0402 PC129 C33P50N0402 +1_25VRUN PC130 C22U6.3X50805-RH 2 GND FB 3A G5 POK PR157 63.4KR1%0402 1 _APL5913KAC-TRL_SOP8-RH A A MSI CORPORATION Title DDR2 RAM POWER, +1.25V Size Document Number Custom Date: 5 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 32 of 41 5 4 3 2 1 PWR_SRC_VTT +5VSUS 813_VDDA PWR_SRC PC33 C2200P50X0402 D PC25 + PD6 S-RB717F_SOT323-RH PC35 C0.1U25Y PC36 C2200P50X0402 C15U25POS 1 813_DH2 813_CS1N 813_VSET1 +5VRUN VSET2 6 4 5 PC41 23 PC42 24 PQ16 NN-SP8K10S_SOP8-RH G3 1 2 PR44 51R1%0402 PR45 100KR1%0402 + PC48 C10U10Y0805 PC46 PC47 C1U16Y C0.1U25Y PR47 C 160KR1%0402 813_CS2P PC43 C4700P25X0402 813_CS2N +5VRUN PR48 124KR1% C1U16Y PWR_SRC_VTT 813_VSET2 PR52 PR50 X_1KR0402 1KR1%0402 Vout=Vref(105k+44.2k)/(124k+44.2k+105k) Vref=2.75V Vout=1.50V PC39 PR51 1KR0402 PR42 C1000P50X0402 9/04 PR54 PC45 C220U2.5SP-LF 813_VREF PR55 X_1KR0402 Vout=Vref(105k)/(124k+44.2k+105k) Vref=2.75V Vout=1.05V 22 PC52 C1000P50X0402 Current Limit at 6 Amp 813_LX2 813_VDDA PC50 PR58 105KR1% 3 +1_5VRUN_PWRGD 1 5 GNDA TSET VSET1 7 X_C1000P50X0402 2 CS2N ON/SKIP2 CS1N VDDA CS2P 21 2 X_2.2R +1_5VRUN 19 20 8 CI55 1 18 LDR2 BST2 17 15 GNDP 16 VDDP 14 CS1P VREF 25 PGD2 OZ813LP_QFN24 VIN 7 PGD1 4 C3300P50X0402 8 LX2 1 RI7 PL8 _CH-2.5U7.5A-RH C22P50N0402-1 813_CS1P PC57 HDR2 LX1 PC44 C0.1U25Y C4700P25X0402 I=18A Diode : Is=4.5A 9 813_DL2 HDR1 813_VREF 3 10 LDR1 13 BST1 11 PC58 127KR1%0402 PC54 813_LX1 VTT_PWRGD C4700P25X0402 PR57 4 12 C22P50N0402-1 PC56 X_C220U2.5SP-LF C PR60 100KR1%0402 2 PR59 51R1%0402 2 PC61 C1U16Y 813_DH1 ON/SKIP1 + PQ23 + PU2 4 X_2.2R PL9 _CH-1.5U10A-RH 1 1 PC55 _C330U2.5POS-2 PC53 C0.1U25Y 6 X_C1000P50X0402 VTT RI16 N-AO4410_SOIC8 3 8 3 2 7 2 1 6 1 5 CI195 PC156 C0.1U25Y PQ22 Current Limit at 10 Amp 813_DL1 I=9A Diode : Is=1.6A N-AO4422_SOIC8 8 7 6 5 2 PC157 C22U25-RH 2 + 2 1 C1U16Y C1U16Y 2 PC60 PL2 80L6_30_0805 PR61 10R 3 PWR_SRC_VTT 1 PC59 D 44.2KR1%0402 PR56 21,31,32 RUN_ON PR53 20KR1%0402 X_100KR0402 0R0402 PR49 X_100KR0402 PC49 813_VSET1 C0.1U25Y PC51 C1000P50X0402 B B PR41 RUN_ON 0R0402 +3VRUN +3VRUN EMI Solution RI4 RI5 RI3 X_0R0402 X_0R0402 X_0R0402 R89 PR46 X_100KR0402 X_100KR0402 +1_5VRUN_PWRGD 21 VTT_PWRGD VTT_PWRGD +1_5VRUN_PWRGD 21 A A J1 X_NC MSI CORPORATION Title +1_5VRUN , VTT POWER Size Document Number Cust om Date: 5 [email protected] GRATIS - FOR FREE 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 33 of 41 5 4 3 2 1 PWR_SRC 1 X_0R0402 X_0R0402 X_0R0402 PC171 C0.1U50Y +3VRUN PWR_SRC PC159 PC160 + C2200P50X0402 C15U25POS 2 RI13 RI17 RI14 N-AO4422_SOIC8 4 DH1_VCORE 1 D 1 2 3 2 DL1_VCORE V_CORE 4 PR177 X_2.2R 4 PC120 + PC112 + PD12 C330U2-RH-1 X_S-RB551V-30_SOD323 2 2 X_C330U2-RH-1 2 PC170 A PQ31 N-AO4410_SOIC8 A 1 2 3 PQ30 N-AO4410_SOIC8 1 2 3 VCORE_GND PC114 + C330U2-RH-1 VCORE_GND C C IMVP_PWRGD 6,19 PL13 CH-0.36U17A-RH 1 5 6 7 8 5 6 7 8 2 2 1 PR171 LX1_VCORE PC118 C0.1U25Y PC164 C0.1U25Y 2 PR134 X_21KR1% 1 +5VRUN 10R PQ29 N-AO4422_SOIC8 4 1 10R PR146 100KR0402 1 2 3 PR144 10R 1 PR170 D 5 6 7 8 PQ28 5 6 7 8 VCORE_GND 1 EMI Solution 40 0R0402 41 4 CPU_VID5 PR118 4 CPU_VID6 PR117 0R0402 43 21 VR_ON PR124 0R0402 44 499R1%0402 45 PR126 0R0402 46 PR127 0R0402CLK_EN# 47 3,6,17 H_DPRSTP# 19 VR_PWRGD_CLKEN# 0R0402 42 1 UGATE2 VID2 BOOT2 PR150 1.4KR1%0402 PHASE2 VID5 LGATE2 VID6 PGND2 VR_ON ISEN2 12 PR145 2KR1%0402 PR156 61.9KR1%0402-RH 11 23 VCORE_GND CLK_EN# 8 PR154 11.5KR1%0402 19 VSUM FB2 FB PC165 C0.22U16X 1 PQ24 N-AO4410_SOIC8 PC117 + C330U2-RH-1 C330U2-RH-1 X_C330U2-RH-1 X_C1000P50X0402 VSUM1 18 B 5 6 7 8 2 PR141 3.65KR1%0402 2 1 PR136 10KR0402 2 1 PR138 1R0402 17 DFB DROOP 16 VSEN RTN 15 PC116 C0.01U25X0402 PC113 + DH1_VCORE & DH2_VCORE LX1_VCORE & LX2_VCORE DL1_VCORE & DL2_VCORE Panasonic ERT-J1VR103J 14 VW PQ25 N-AO4410_SOIC8 PR172 2.61KR1%0402 PC166 C0.015U16X0402 COMP PC122 C47P50N0402 PC110 4 100 mil Trace list for layout PR174 11KR1%0402 VO PR168 X_2.2R + 4 PR176 10KRT-LF-2 9 V_CORE PD10 X_S-B340LA_SMA PC125 C1000P50X0402 25 VDIFF 4.42KR1%0402-RH 5 6 7 8 1 PR139 X_10KR0402 PC111 C0.22U16X OCSET PL12 CH-0.36U17A-RH 1 PC158 29 PC126 C0.033U25X 10 2 DL2_VCORE 30 DPRSTP# PC127 C390P50X PR155 28 DPRSLPVR VSUM B LX2_VCORE PC106 C0.22U16X VID4 NC 13 PR129 2.2R0402 26 VID3 PR149 1.82KR1%0402 PC121 C470P50X0402 PR131 X_21KR1% 2 48 3V3 VIN VID1 PC109 C4.7U10Y0805 0R 1 0R0402 PR119 PR135 PQ26 N-AO4422_SOIC8 4 C 2 PR120 CPU_VID4 27 VID0 4 Iocset*Roc=Iocp*Rdroop R 8 6 =Roc=55A*2.1m Ohms/10uA ~ 11.5K Where : R d r oop is Intel spec : -2.1m Ohms I ocp is desire over current I o c set is recommendation 10uA from Rbias 1 CPU_VID3 4 DH2_VCORE 1 C15U25POS 2 4 2 + 1 39 PVCC 31 C2200P50X0402 2 0R0402 +5VRUN SOFT PC162 C0.1U50Y C PR121 NTC PC108 C0.22U16X PC161 A CPU_VID2 PR128 1R1% PQ27 N-AO4422_SOIC8 PC169 1 2 3 4 24 VR_TT# 5 6 7 8 38 PR130 X_4.02KR1%0402 1 2 3 0R0402 33 1 2 3 PR122 Current Limit at 55Amp 32 5 6 7 8 PR123 CPU_VID1 PWR_SRC 1 2 3 CPU_VID0 ISEN1 1R0402 1 PC124 7 C0.015U16X0402 VCORE_GND 0R0402 37 PGND1 RBIAS PR133 2 6 LGATE1 PMON 10KR0402 2 5 PHASE1 PSI# PR132 1 4 4 PR125 1 2 PR148 147KR1%-RH 4 6,19 PM_DPRSLPVR 2 2 3 34 1 2 X_0R0402 C0.01U25X0402 1 2 VCORE_GND 0R0402 PR152 470KRT0402-LF-1 PC123 2 3.65KR1%0402 PC107 C0.22U16X PR151 VCORE_GND PR137 2.2R0402 VCORE_GND PR147 TP86 PR153 4.02KR1%0402 2 PR140 1 PC128 X_C1U16Y 36 1 0R 2 C PSI# VR_ON VSUM PR169 1 3 21 BOOT1 GND_T ISL6262ACRZ-T_QFN48-RH 35 1 For layout far distance UGATE1 GND PD11 X_S-B340LA_SMA 2 49 Throttling temp. 105 degree C PU5 PGOOD 21 VDD PC163 C1U16Y 20 22 X_C1000P50X0402 J16 X_NC VCORE_GND PR175 1KR1%0402 PC168 C0.22U16X C lose to Phase 1 Inductor VCORE_GND PR173 3.6KR1%0402 PC167 ISL6262_VO C180P50N0402 PC115 C0.01U25X0402 R d r oop2=[N*Rdroop/(DCR*G)-1]*Rin R 5 2 = [2*2.1m/(1.8m*0.83)-1]*1K=1.8K R d r oop:Intel spec. -2.1m Ohms PC119 C0.01U25X0402 VCORE_GND VCORE_GND VCCSENSE 4 A A VSSSENSE 4 PR142 10R PR143 10R Parallel MSI CORPORATION Parallel Title CPU POWER Size Document Number Custom Date: 5 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 1 Sheet 34 of 41 A B C D E F G H +3VRUN PWR_SRC 1 1 +5VRUN PR67 10R PR94 10KR0402 PL3 80L6_30_0805 PR66 10R PQ20 PC154 1 5 6 7 8 PWR_SRC PC77 C0.01U25X0402 PC153 N-AO4422_SOIC8 PC152 + 4 C0.1U50Y C22U25-RH Current Limit at 15Amp 1 2 3 31 2 PR72 0R0402 23 PR71 0R0402 24 PR77 0R0402 25 GFX_VID_2 PR79 0R0402 26 GFX_VID_3 PR81 0R0402 6 GFX_VID_0 6 GFX_VID_1 6 6 27 PR83 20KR0402-2 6 PR82 0R0402 PR85 0R0402 GFX_VR_EN 28 29 PR86 PR90 0R0402 30 PR166 X_2.2R PR68 7.68KR1%0402 X_S-B340LA_SMA PC74 C2.2U16Y0805 22 N-AO4410_SOIC8 1 C330U2-RH-1 X_C330U2-RH-1 PR167 18 UGATE PR70 2.2R0402 17 BOOT VID0 PC73 + PC155 X_C1000P50X0402 PR75 SOFT PC72 + PQ21 RBIAS PVCC PC97 2 C0.01U25X0402 PD7 4 2 1 2 2 PR73 1R1% +5VRUN PR104 150KR1%0402 1 ISL6263CRZ-T_QFN32-RH FDE C 32 +VGFX_CORE 1 PU4 GND_T A PR100 10KR0402 VSS G4 5 6 7 8 33 0.7~1.25V PL10 CH-0.88U27A-RH 1 2 3 15 +3VRUN PGOOD C1U16Y VIN VDD PC68 FDE single high should be < 3.3V 14 16 2 C2200P50X0402 3.57KR1%0402 10KRT-LF-2 2 VID1 PC67 C0.22U16X VID2 PR78 19 PHASE VID3 21 LGATE 4.53KR1%0402 VID4 20 PGND I2UA VR_ON PC98 X_C1000P50X0402 AF_EN X_30KR0402 PR107 2.21KR1%0402-RH 3 OCSET PR105 12.1KR1%0402 PC101 PR114 4.99KR1%0402 7 13 VSUM VDIFF PC81 C82000P16X C560P50X0402 Iocset*Roc=Iocp*Rdroop R191=Roc=15A*8m Ohms/10uA ~ 12.1K Where : Rdroop is Intel spec : -8m Ohms Iocp is desire over current Iocset is recommendation 10uA from Rbias PC84 6 PC100 C0.12U10X-LF FB PR106 365KR1%0402 12 VO C1000P50X0402 3 DFB PR88 1KR1%0402 11 VW 9 PC99 DROOP 4 VSEN 6.98KR1% 10 PR115 COMP 8 C68P10N0402 3 5 C180P50N0402 RTN PC105 PC87 C0.1U10X0402 PC94 PR89 C1000P50X0402 6.04KR1%0402 PC92 C330P50X0402 PC95 C1000P50X0402 PC96 C1000P50X0402 PR95 0R0402 PR109 0R0402 Parallel 4 4 J2 X_NC MSI CORPORATION Title Graphics Core Size C Date: A [email protected] GRATIS - FOR FREE B C D E F G Document Number Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 35 H of 41 5 4 3 2 1 MIC2_VREFOUT_L R269 475R1%0402 SMB_CLK_M2 11,12,15,19 +3VRUN J17 MIC0P MIC0N MIC1P MIC1N C 46 1 2 3 4 5 47 48 6 R278 NC 25 NC 26 27 SCLK_CE 28 NC 29 NC 30 NC 31 32 NC 33 NC IRQ_ANA NC NC VSS_CODEC XTAL_OUT NC TPAD U19 FM2010-N-RH 1 AGND +3VRUN NC GND 8/23 R289 34 NC NC 100KR0402 TEST NC AGND_DSP 49 MOLEX_53261-0490 N32-1040430-H06 53398_04 35 NC NC 23 22 R263 10KR0402 21 +1.8VRUN_FM2010 20 19 18 17 16 TP105 15 14 13 C NC 45 VDD 24 12 AGND_DSP NC XTAL_IN 44 SHI_S NC 43 NC 11 42 RESET 10 R262 2.2KR0402 MIC0_P VDD_CODEC R254 2.2KR0402 NC VCOM 41 MIC0_N 9 40 NC 39 MIC0_P 8 MIC0_N C0.1U10X0402 7 C0.1U10X0402 SDA_CE LINE_OUT C275 C0.01U25X0402 C279 MIC1_P LINE_IN_N 38 6 MIC1_P +1.8VRUN_FM2010 NC 5 C0.1U10X0402 D NC NC 37 LINE_IN_P C276 MIC0P MIC1_N 4 MIC0N C0.1U10X0402 3 C270 MIC1P C267 C0.01U25X0402 C272 VREF MIC1N PWD_LED AGND_DSP MIC1_N C286 2.2U6.3X NC R257 2.2KR0402 D 2 R264 2.2KR0402 36 SMB_DATA_M2 11,12,15,19 100KR0402 C307 LINE2_L 27 LINE2_R R285 C0.1U10X0402 1 + 2.2KR0402 C292 C298 C0.1U10X0402 4 +1.8VRUN_CODEC 3 - R277 AGND_DSP C314 R291 2 27 U21 5 C0.22U6.3X50402 2.2KR0402 LM321MFX C299 C0.1U10X0402 C0.22U6.3X50402 C4.7U6.3X5-1 R279 MIC0P R268 X_0R0402 MIC0N R393 X_0R0402 CODEC_HDA_BITCLK C297 17,27 10KR0402 R276 10KR0402 1KR0402 INT_MIC C311 C1000P50X0402 B 27 INT_MIC B AGND_DSP AGND_DSP C291 For single internal MIC C0.01U25X0402 AGND_DSP +3VRUN +1.8VRUN_CODEC U18 2 C265 C256 3 C1000P50X0402 C4.7U6.3X5-1 IN L26 VOUT 5 GND EN 1 ADJ 4 1 2 300L300m_350 L25 1 2 R260 80L3_70_0805 4.87KR1%0402-RH 2 AME8804 SOT23_5_NPC30X L27 2 300L300m_350 1 1 +1.8VRUN_FM2010 Vout = 1.8V C488 C293 C0.1U10X0402 C280 C0.1U10X0402 C283 C262 C0.1U10X0402 C263 C0.1U10X0402 C4.7U6.3X5-1 A C4.7U6.3X5-1 A R259 10KR1%0402 MSI CORPORATION AGND_DSP AGND_DSP Title AGND_DSP Array Mic FM2010 AGND_DSP Vout=1.215(Ru+Rd)/Rd Size Document Number Custom Date: 5 4 3 2 Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 36 of 41 5 4 3 2 1 +3VRUN PWR_SRC VTT H14 X_holes_p_r276d118 D H18 X_holes_p_r276d118 H8 X_holes_p_r276d118 1 H21 X_holes_p_r276d118 1 H20 X_holes_p_r276d118 1 H2 X_holes_p_r276d118 1 H13 X_holes_p_r276d118 1 H3 X_holes_p_r276d118 CI112 CI117 CI116 CI94 CI100 CI66 X_C0.1U10X0402 X_C47P50N0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 CI81 CI102 CI53 CI190 CI104 CI188 CI185 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 H17 X_holes_p_r276d118 H26 X_HOLE157 H25 X_HOLE157 H1 X_holes_p_r276d118 H6 X_holes_p_r276d118 H4 X_holes_p_r276d118 1 1 1 1 1 1 +5VRUN H10 X_holes_p_r276d118 H28 X_HOLE157 X_C0.1U10X0402 C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 CI168 X_C0.1U10X0402 CI28 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 CI38 CI75 CI52 CI30 CI4 CI74 CI11 CI2 CI197 CI198 CI36 CI98 CI196 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 CI24 X_C0.1U10X0402 CI50 CI184 CI20 CI34 CI130 CI177 CI64 CI8 CI27 CI187 CI212 CI19 X_C0.1U10X0402 CI39 CI83 CI45 CI118 X_C0.1U10X0402 X_C0.1U10X0402 CI78 CI77 C0.1U10X0402 X_C0.1U10X0402 1 1 Pannel +5VRUN CI25 X_C0.1U25Y +3VRUN +5VRUN CI76 CI6 CI85 CI1 CI84 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 +3VRUN C0.1U10X0402 C0.1U10X0402 X_C0.1U10X0402 +3VSUS VTT CI47 X_C0.1U10X0402 CI5 CI7 CI9 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 +5VRUN +3VSUS +3VRUN H23 STAND OFF,M2 H3 H24 STAND OFF,M2 H3 H15 X_HOLES_R177D91 H7 X_HOLES_R177D91 H9 X_HOLES_R177D91 H22 STANDOFF H16 X_holes_p_r276d118 C E2B-1022020-A89 MDC Stand off H5 X_HOLES_R177D91 H19 X_HOLES_R177D91 H11 X_holes_p_r276d118 CI35 CI70 CI139 CI16 CI71 CI82 CI43 H12 X_holes_p_r276d118 X_C0.1U25Y X_C0.1U25Y X_C0.1U25Y X_C0.1U25Y X_C0.1U25Y X_C0.1U25Y C0.1U25Y X_C0.1U10X0402 X_C0.1U10X0402 CI183 X_C0.1U10X0402 C +5VRUN X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 1 L1_5mil_55_Ohm L6_5mil_55_Ohm X_H1X2_black-RH X_H1X2_black-RH X_H1X2_black-RH J7 J13 J6 J14 CI115 CI199 CI93 X_C0.1U10X0402 X_C0.1U10X0402 C0.1U10X0402 CI114 X_C0.1U10X0402 CI79 CI23 CI80 CI44 CI135 CI31 CI123 CI134 CI72 +VGFX_CORE L1_DIFF_4/7/4_100_Ohm+ B L3_DIFF_4/7/4_100_Ohm+ X_H1X2_black-RH X_H1X2_black-RH J5 X_H1X2_black-RH L4_DIFF_4/7/4_100_Ohm- X_H1X2_black-RH J26 L4_DIFF_8/5/8_70_Ohm+ X_H1X2_black-RH X_H1X2_black-RH J23 J25 J27 J29 L3_DIFF_5/5/5_85_Ohm- X_H1X2_black-RH X_H1X2_black-RH X_H1X2_black-RH J32 J34 J22 L4_DIFF_4.5/5.5/4.5_90_Ohm+ L6_DIFF_4.5/5.5/4.5_90_Ohm+ X_H1X2_black-RH X_H1X2_black-RH J31 J33 J21 X_H1X2_black-RH CI178 CI180 X_C0.1U10X0402 X_C0.1U10X0402 L6_DIFF_4.5/5.5/4.5_90_Ohm- CI46 X_C0.1U10X0402 CI131 X_C0.1U10X0402 SMDDR_VTERM CI152 CI147 CI159 CI169 CI161 CI153 CI143 X_H1X2_black-RH X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 CI209 CI175 CI176 CI181 CI179 CI211 X_H1X2_black-RH RI8 X_0R RI6 X_0R PAD4 PAD3 PAD1 PAD8 PAD9 PAD5 PAD7 PAD6 PAD2 X_MS-55101-RH X_MS-55101-RH X_MS-55101-RH X_MS-55101-RH X_MS-55101-RH X_MS-55101-RH X_MS-55101-RH X_MS-55101-RH X_MS-55101-RH X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 J15 X_NC J19 X_NC 1 1 1 1 1 1 1 1 AGND 1 X_C0.1U25Y X_C0.1U25Y X_C0.1U25Y X_C0.1U25Y X_C0.1U25Y CI57 X_C0.1U25Y CI92 X_C0.1U25Y CI133 X_C0.1U25Y CI164 CI144 CI120 CI172 CI129 CI132 CI113 CI157 CI165 CI146 CI156 CI140 CI137 CI128 CI121 CI68 CI145 CI127 CI119 CI122 CI136 CI148 CI206 CI150 CI163 CI149 CI202 CI200 CI205 CI204 CI203 CI108 CI201 CI106 CI110 CI158 CI111 CI160 CI208 CI107 CI207 AGND L4_DIFF_5/5/5_85_Ohm- L6_6mil_50_Ohm X_H1X2_black-RH +3VRUN CI174 CI171 CI173 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.01U25X0402 +1_8VDIMM B +1_8VDIMM +1_5VRUN X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 C0.1U10X0402 C0.1U10X0402 X_C68P10N0402 C0.1U10X0402 C0.1U10X0402 X_C0.1U10X0402 X_C0.01U25X0402 C0.1U10X0402 C0.1U10X0402 X_C0.01U25X0402 C0.1U10X0402 X_C0.01U25X0402 X_C0.01U25X0402 X_C0.1U10X0402 X_C0.01U25X0402 X_C0.01U25X0402 C0.1U10X0402 X_C0.1U10X0402 C0.1U10X0402 CI124 X_C0.1U10X0402 CI125 X_C0.1U10X0402 +1_8VDIMM CI170 CI151 CI162 CI138 CI154 4 3 2 SMDDR_VTERM X_C0.1U10X0402 X_C0.1U10X0402 X_C0.01U25X0402 X_C0.1U10X0402 X_C0.1U10X0402 +1_8VDIMM CI101 VTT X_C0.01U25X0402 A VTT +1_5VRUN CI54 X_C0.01U25X0402 MSI CORPORATION Title Screw & EMI Size Date: [email protected] GRATIS - FOR FREE X_C0.1U10X0402 +3VRUN C 5 PWR_SRC_VDDQ CI141 +1_8VDIMM L4_5mil_50_Ohm X_H1X2_black-RH L4_DIFF_4.5/5.5/4.5_90_Ohm- X_C0.1U10X0402 +1_5VRUN L4_DIFF_5/5/5_85_Ohm+ X_H1X2_black-RH L4_DIFF_8/5/8_70_Ohm- CI210 J30 L3_DIFF_5/5/5_85_Ohm+ X_H1X2_black-RH L3_DIFF_8/5/8_70_Ohm- ADD5V X_C0.1U25Y X_C0.1U25Y X_C0.1U25Y X_C0.1U25Y X_C0.1U10X0402 X_C0.1U10X0402 X_H1X2_black-RH J28 L3_DIFF_8/5/8_70_Ohm+ X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 C0.1U10X0402 J12 L6_DIFF_4/7/4_100_Ohm- X_H1X2_black-RH J24 X_H1X2_black-RH J4 L3_DIFF_4/7/4_100_Ohm- CI97 CI96 CI95 CI91 CI87 CI103 L4_DIFF_4/7/4_100_Ohm+ X_H1X2_black-RH J11 L1_DIFF_4/7/4_100_Ohm- A L6_DIFF_4/7/4_100_Ohm+ V_CORE CI99 CI109 L4_4mil_55_Ohm X_H1X2_black-RH +3VALW PWR_SRC J8 L3_4mil_55_Ohm X_C0.1U10X0402 PWR_SRC +1_25VRUN J9 CI41 X_C0.1U10X0402 X_C0.1U10X0402 CPU & NB Heatsink J10 X_C0.1U10X0402 X_C0.1U10X0402 +3VSUS CI15 CI126 CI182 CI189 CI193 Fan Module J3 +3VALW CI18 CI17 1 1 CI51 CI191 +3VALW AVDD18 1 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 X_C0.1U10X0402 +3VRUN 1 1 E2B-1003011-A89 1 1 1 1 1 PWR_SRC CI10 CI26 +3VSUS CI12 CI186 CI61 CI37 CI67 CI21 CI29 CI13 CI3 +3VSUS D VTT CI42 CI194 CI192 1 1 1 1 H27 X_HOLE157 CI167 CI59 CI63 CI142 CI105 CI49 CI88 CI62 CI65 CI73 CI69 CI40 CI90 CI86 CI166 CI14 CI33 CI56 Document Number Rev 0B MS-1221 Wednesday, September 06, 2006 1 Sheet 37 of 41 5 4 3 2 1 PCB1 PCB D D PCB_V0B P30-122110B-T53,健鼎無錫,12,崑山微盟廠(MSIK) P30-122110B-D05,昆穎(定穎大陸),12,崑山微盟廠(MSIK) P30-122110B-Y34,元茂,12,崑山微盟廠(MSIK) UME1 BIOS LABEL C C X_BIOS_LABEL FM18 FM20 FM15 X_F_PAD_M100 X_F_PAD_M100 X_F_PAD_M100 FM17 FM24 FM12 X_F_PAD_M100 X_F_PAD_M100 X_F_PAD_M100 FM14 FM16 FM19 X_F_PAD_M100 X_F_PAD_M100 X_F_PAD_M100 B B A FM27 FM26 FM21 X_F_PAD_M100 X_F_PAD_M120 X_F_PAD_M120 FM25 FM23 FM11 X_F_PAD_M120 X_F_PAD_M120 X_F_PAD_M120 FM28 FM22 FM13 X_F_PAD_M120 X_F_PAD_M120 X_F_PAD_M120 FM34 FM30 FM33 X_F_PAD_M120 X_F_PAD_M120 X_F_PAD_M120 FM31 FM29 FM32 X_F_PAD_M120 X_F_PAD_M120 X_F_PAD_M120 FM36 FM35 X_F_PAD_M120 X_F_PAD_M120 A MSI CORPORATION Title Non-Footprint for BOM Size B Date: 5 4 3 2 Document Number Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 38 of 41 5 4 3 0 PWRSW# +3VSUS 1 SUS_ON D Pin 2 Pin 155 2 +3VSUSPG +3VRUN RUND RUN_ON KB_PWRBTN# Pin 168 Pin 27 5 +5VRUN 1 Power Button D +5VSUS 2 3 RSMRST# Delay 10ms Pin 149 Pin 91 Pin 75 TPS51120 4 PM_SLP_S4# Pin 70 VTT RSMRST# PM_SLP_S5# 5 PM_SLP_S3# Pin 176 5 RUN_ON +1_25VRUN C C ICH8M +1_5VRUN 6 +1_25VRUN_PWRGD VTT_PWRGD 6 +1_5VRUN_PWRGD KBC 8 OZ813LP 4 DIMM_ON +1_8VSUS 6 Pin 4 Pin 55 VR_ON Delay 99ms VR_ON SMDDR_VTERM VHCORE VR_ON IMVP_PWRGD PGD_IN ISL6262 +1_8VSUS_PWRGD B B SC486IMLTRT +1_5VRUN_PWRGD VTT_PWRGD 7 ALLSYSPG Pin 3 +1_25VRUN_PWRGD A A MSI CORPORATION Title KBC_CTR_PWR_BD Size B Date: 5 [email protected] GRATIS - FOR FREE 4 3 2 Document Number Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 39 of 41 5 4 3 2 Power Up DRIVE SOURCE 1 Power Down PWR_SRC PM_SLP_S3>260 ms RUN_ON PWRSW- MANUAL 260 ms D EC SUS_ON EC KB_PWRBTN- D RUN POWER VR_ON 1RCTCLK~2RTCCLK SUS POWER (+3VSUS/+5VSUS) +3VSUS POWER GOOD +3VSUSPWROK PM_SLP_S4DIMM_ON >10 ms EC RSMRST- DIMM POWER SB PM_SLP_S5- PM_SLP_S5- SB PM_SLP_S4- EC DIMM_ON 1RCTCLK~2RTCCLK RSMRST- S3 DIMM POWER (+1_8VDIMM/SMDDR_VTERM) C C PM_SLP_S3- SB PM_SLP_S3- RUN_ON EC RUN_ON RUN POWER (+3VRUN/+5VRUN +1_5VRUN/VTT) VTT/1.25V/1.5V POWER GOOD RUN POWER ALLSYSPG 20 us VR_ON EC ICS9LP505 VHCORE ISL6262 CLK_EN# VR_ON >99 ms PM_SLP_S4DIMM_ON DIMM POWER VR_PWRGD_CLKEN ISL6262 CLK_PWRGD SB B PM_SLP_S5- (TO VRMPWRGD) ICS9LP505 1.8 ms CLOCK B IMVP_PWRGD (PWROK FOR SB/NB) ISL6262 SB CPU_PWRGD SB PLTRST(TO NB_RST-) SB PCIRST- NB CPURST- 6.3 ms A A MSI CORPORATION Title Power Sequency Size C Date: 5 4 3 2 Document Number Rev 0B MS-1221 Wednesday, September 06, 2006 1 Sheet 40 of 41 5 4 3 2 1 D D C C B B A A MSI CORPORATION Title Change History Size B Date: 5 [email protected] GRATIS - FOR FREE 4 3 2 Document Number Rev 0B MS-1221 Wednesday, September 06, 2006 Sheet 1 41 of 41