Transcript
MSB-118 8 Port RS-232/422/485 uPCI Card Quick Installation Guide Cable: CBL-M68M9x8-100 Male SCSI-III 68 pins to 8 x Male DB9 ,1 Meter Cable
MSB-118 Profile
Male DB9 Connector: Device-side Pin Assignments
Getting Stared 1. 2. 3. 4. 5. 6.
Power off PC Find a PCI slot Remove the bracket Switch the SW1 to SW4 for the hardware interface of port 1 to port 8 Insert MSB-118 into the PCI slot Tighten the MSB-118 with a screw
SW1 to SW4 Setting SW1/SW2/SW3/SW4 are used to configure the hardware interface mode of Port 1 to Port 8. The configuration of the RS-232, RS-422 and RS-485 interface are shown as following:
For Example Port 1 is configured as RS-232, Port 2 is RS-422 and Port 3 is RS485 interface, SW1 to SW4 setting are as follow:
P1
P2
P3
SW1
ON
OFF
OFF
SW2
OFF
OFF
ON
SW3
OFF
OFF
ON
SW4
OFF
OFF
ON
Pin No. 1 2 3
RS-232 DCD RxD TxD
RS-422 TxDTxD+ RxD+
RS-485
4 5
DTR GND
RxDGND
DataGND
6 7 8 9
DSR RTS CTS RI
RTSRTS+ CTS+ CTS-
Data+
Female SCSI-68 Connector: Board Side
Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
RS-232 P1:DCD P1:DSR P1:RxD P1:RTS P1:TxD P1:CTS P1:DTR P1:RI GND P3:DCD P3:DSR P3:RxD P3:RTS P3:TxD P3:CTS P3:DTR
RS-422 P1:TxDP1:RTSP1: TxD+ P1:RTS+ P1:RxD+ P1:CTS+ P1:RxDP1:CTSGND P3:TxDP3:RTSP3: TxD+ P3:RTS+ P3:RxD+ P3:CTS+ P3:RxD-
17
P3:RI
P3:CTS-
RS-485
P1:Data+ P1:DataGND
P3:Data+ P3:Data-
18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68
P5:DCD P5:DSR P5:RxD P5:RTS P5:TxD P5:CTS P5:DTR P5:RI GND P7:DCD P7:DSR P7:RxD P7:RTS P7:TxD P7:CTS P7:DTR P7:RI P2:DCD P2:DSR P2:RxD P2:RTS P2:TxD P2:CTS P2:DTR P2:RI GND P4:DCD P4:DSR P4:RxD P4:RTS P4:TxD P4:CTS P4:DTR P4:RI P6:DCD P6:DSR P6:RxD P6:RTS P6:TxD P6:CTS P6:DTR P6:RI GND P8:DCD P8:DSR P8:RxD P8:RTS P8:TxD P8:CTS P9:DTR P9:RI
P5:TxDP5:RTSP5: TxD+ P5:RTS+ P5:RxD+ P5:CTS+ P5:RxDP5:CTSGND P7:TxDP7:RTSP7: TxD+ P7:RTS+ P7:RxD+ P7:CTS+ P7:RxDP7:CTSP2:TxDP2:RTSP2: TxD+ P2:RTS+ P2:RxD+ P2:CTS+ P2:RxDP2:CTSGNDP4:TxDP4:RTSP4: TxD+ P4:RTS+ P4:RxD+ P4:CTS+ P4:RxDP4:CTSP6:TxDP6:RTSP6: TxD+ P6:RTS+ P6:RxD+ P6:CTS+ P6:RxDP6:CTSGND P8:TxDP8:RTSP8: TxD+ P8:RTS+ P8:RxD+ P8:CTS+ P8:RxDP8:CTS-
P5:Data+ P5:DataGND
P7:Data+ P7:Data-
P2:Data+ P2:DataGND
P4:Data+ P4:Data-
P6:Data+ P6:DataGND
P8:Data+ P8:Data-
Driver Installation on Windows XP Step 1 After the first time system power up a message window will appear as follow: Click the option as above then click Next button
Step 3 A warning window will appear and click Continue anyway
Configure Serial Ports Use Device Manager to configure the port mapping in the Window XP and double click on the port to be configured
Step 2 Specify the path of the diver in the Artila CD then Click Next button
Step 4 Click Finish to complete the driver installation
Use Advance Settings dialog to configure the port number mapping in XP
Enter the Setting dialog page and select the hardware interface. If the RS-485 is selected, the driver can configure the DTR pin to enable the transmitter for RS-485 half duplex flow control. MSB-118 uses Active High mode for RS-485 hardware flow control if RS-485 is selected. Remember to switch the SW1~SW4 for the hardware interface of each port.
After all the settings are complete, click the Detect Crystal Frequency button and if the hardware and driver are installed correctly, it will show the correct Frequency of 18.4320 MHz
Windows NT4 Driver Installation 1. Run “Install_Serial.exe” from the \MSB-118\WinNT4 subdirectory on the CD 2. When the install application start, click next to continue 3. Ensure “Install” is selected, then click Next to continue 4. Click OK to accept the license agreement 5. The system will install the driver and start it. The ports are immediately ready for use Windows 95 Driver Installation 1. The system will detect the device and ask which driver to install. Select “Driver from disk provided by hardware manufacture” and click OK 2. Specify the path “\MSB-118” subdirectory on the CD and click OK 3. The system will install the OX16PCI954 device and OX16C954 device 4. Once the main drivers are installed, the system installs the UART ports automatically Window 98 Driver Installation 1. The system will detect the device and start the “Add new hardware” wizard. Click Next to continue 2. The system will suggest that it searched for the best driver for the device. Click Next to confirm 3. Point the wizard at the path “\MSB-118” subdirectory on the CD. 4. Once the system found the driver, click Next to continue 5. After the system install the OX16PCI954 and OX16C954 driver, click Finish 6. Once the main drivers are installed, the system installs the UART ports automatically Windows 2000 Driver Installation 1.The system will detect the device and ask which driver to install. Click Next 2. Select “Search for a suitable driver for my device” and click Next Check the “Specify a location” box. Click Next 3. Enter the path “\MSB-118” to search and click OK 4. The system will search for a driver. When it finds it, click Next. The files will be copied and the driver installed. Click Finish. 5. Once the PCI devices are installed, the system will install the UART ports automatically.