Preview only show first 10 pages with watermark. For full document please download

Msha*-approved Gas Detection Solutions

   EMBED


Share

Transcript

D-37660-2015 MSHA*-Approved Gas Detection Solutions *Mine Safety and Health Administration D-37661-2015 02 | PRODUCT CATALOG FOR MSHA GAS DETECTION D-37662-2015 PRODUCT CATALOG FOR MSHA GAS DETECTION The Drägerman always stands guard Mines represent one of the world’s most dangerous work environments. For generations, miners have relied on Dräger for quality products to protect their lives. The technologies offered by Dräger’s breathing apparatus have paved the way for an entirely new profession: mine rescue. All over the world, mine rescuers are called “Drägermen”—even today. Now MSHA-approved Dräger’s mine operations portfolio encompasses an integrated safety concept that improves mine safety and includes a comprehensive line of MSHA-approved products that detect hazardous levels of methane, oxygen deficiency, and toxic gases. Whether you need personal area monitors to continually evaluate oxygen levels or take spot measurements for combustible gases, Dräger’s single and multi-gas monitors are fast, accurate, and reliable. | 03 PRODUCT CATALOG FOR MSHA GAS DETECTION Dräger Pac Series Gas Detectors The Dräger Pac® series is composed of fast, accurate, reliable and easy-to-use personal single gas detectors. The devices are extremely robust, featuring clear warning signals and language-free displays. Their cutting-edge sensor technology delivers reliable results every time. The impact-resistant and chemical-resistant rubber housing meets the requirements of IP68, so the devices can be exposed to spray water. A stable and rotating alligator clip ensures secure fastening to your clothing. Equipped with the latest Dräger XXS miniature sensor technology, the Dräger Pac series represents excellence in the field of gas detection. The devices are extremely durable, highly responsive, and have a variety of features for capturing events, including the ability to adjust the frequency of functional tests and calibrations individually. DRÄGER PAC 7000 D-16522-2009 04 | ––Measures carbon dioxide, sulfur dioxide, chlorine, hydrogen cyanide, ammonia,nitrogen dioxide, nitric oxide, phosphine, carbon monoxide, hydrogen sulfide and oxygen or organic vapors ––Warranty of 2 years, optional 5 year warranty for the H2S, O2, and CO devices ––Estimated sensor service life of 5–8 years ––Easy to replace batteries and sensors ––Service life of the device is not limited ––Replaceable dust and water filters ––Data logger for storage of gas concentrations and events withdate and time (120 hours at 1 record per minute) ––Configurable TWA and STEL alarms ––Recording maximum concentrations ––Rapid functional tests on site ––Automatic function test option PRODUCT CATALOG FOR MSHA GAS DETECTION DRÄGER X-AM 2500 D-59025-2012 Dräger’s X-am® 2500 accurately detects O2, CO, NO2, SO2, CH4, and H2S and combines reliable sensor technology with long battery life and intuitive operation in an instrument that defines safety. The X-am 2500 is compatible with Dräger’s X-dock® testing and calibration station. X-dock is Dräger’s new solution for efficient maintenance and comprehensive equipment management. Used for functional testing and complete documentation, X-dock can complete bump tests in as little as 15 seconds with more than 40% less gas consumption than competitive instruments. The X-am 2500 is also compatible with the Dräger Bump Test Station. DRÄGER X-AM 5000 D-59025-2012 The smallest gas detection instrument for up to five gases, the Dräger X-am 5000 belongs to a new generation of detectors developed especially for personal monitoring. It reliably measures oxygen, organic vapors, combustible gases, and harmful concentrations of CO, H2S, CO2, Cl2, HCN, NH3, NO2, PH3, SO2, and many others with high sensitivity to keep you safe. The Dräger X-am 5000 is tough. It’s dust-resistant according to IP67, and remains fully functional even after falling into water. The integrated rubber protection and shock-proof sensors give additional resistance to impact and vibration. Moreover, the Dräger X-am 5000 is insensitive to electromagnetic interference. This means you can count on it—even in the harshest conditions. | 05 PRODUCT CATALOG FOR MSHA GAS DETECTION DRÄGER X-DOCK 5300/6300/6600 D-47894-2012 06 | Automatic bump tests, calibration, reduced test gas consumption, short testing times and comprehensive documentation come standard in the X-dock to let you work smarter and safer. Testing is as simple as inserting your Dräger gas detection instrument and closing the lid. The X-dock immediately detects all sensor combinations and automatically tests and adjusts when all of the required test gases are connected. All generated data is documented in the database. Ensure MSHA Calibration Compliance All Dräger MSHA-approved gas monitors feature adjustable bump test and calibration intervals that alert you when a bump test or calibration is required. These intervals can be set for each instrument and are automatically recognized by the X-dock during a routine bump test. All calibration data is stored, helping to ensure that all monitors in use are calibrated and documented.  Reduced test gas means reduced costs With a reduced gas flow (300 mL/min instead of 500 mL/min = 40% decrease) per module, you save money on test gases. Short testing times also reduce overall maintenance requirements. Dräger’s patent-pending innovative valve only needs one pump, which means less wear on parts for you. The valves automatically switch the test gases and the fresh air source as well. Time is money, you save both with X-dock Up to 10 modules can be connected to the X-dock, allowing you to test gas detection instruments simultaneously or individually. The automatic bump test also saves time, because the test takes as little as 15 seconds. All Dräger test gas cylinders are already stored in the database—just enter the part number to automatically fill the fields required for the gas configuration, eliminating the need for manual data entry. Additional X-dock benefits ––Touchscreen operation at the master controller station ––Up to three configurable test routines ––Automatic permeability tests ––Automatic tests of all alarm elements (acoustic, visual and vibration alarms) ––Optional charging function for X-am 1/2/5x00 ––Easy-to-replace seal cartridge ––12V operation (e.g., in vehicles) available ––Can be expanded with up to 10 modules (X-dock 6300/6600) ––Sensor performance testing PRODUCT CATALOG FOR MSHA GAS DETECTION DRÄGER X-DOCK MANAGER SOFTWARE D-57160-2012 Companion software for X-dock provides: ––An overview page ––Gas exposure in specific areas ––Number of executed tests ––Device availability ––Overview of created/sent reports ––Templates for regular reports ––An issue and return function ––Monitoring of stations in the network ––Overview of devices ORDERING INFORMATION MSHA-APPROVED CALIBRATION Part No. Dräger X-dock® Dräger X-dock® 5300 for Dräger X-am® 125 83 21 880 Set consisting of one master (3 gases) with power supply and one instrument module for the instruments Dräger X-am® 125 Dräger X-dock® 5300 for Dräger Pac® 83 21 881 Set consisting of one master (3 gases) with power supply and one instrument module for the instruments Dräger Pac 3500/5500 and Dräger Pac 7000 Dräger X-dock® Module for Dräger X-am® 125 83 21 890 Cradle module for one instrument if the Dräger X-am 125 series Dräger X-dock® Module for Dräger X-am® 125+ 83 21 891 Cradle module for one instrument if the Dräger X-am 125 series with and additional charging function Dräger X-dock® Module for Dräger Pac® 83 21 892 Cradle module for one instrument if the Dräger Pac series Dräger X-dock® 6300 Master 83 21 900 With 3 test gas connections plus fresh air. At least 1 module must be ordered, extendable to max. 10 modules Dräger X-dock® 6600 Master 83 21 901 With 6 test gas connections plus fresh air. At least 1 module must be ordered, extendable to max. 10 modules MSHA-APPROVED SINGLE GAS MONITORS Dräger Pac® Dräger Pac® 7000, CO, 0–1,999 ppm, 1 ppm resolution, MSHA A1 35 ppm/A2 50 ppm Dräger Pac® 7000, O2, 0–25% Vol., 0.1% Vol. resolution, MSHA A1 19.5% Vol./A2 23.5% Vol Dräger Pac® 7000, H2S, 0–100 ppm, 1 ppm resolution, MSHA A1 10 ppm/A2 20 ppm Part No. 45 42 199 45 42 198 45 42 197 | 07 08 | PRODUCT CATALOG FOR MSHA GAS DETECTION ORDERING INFORMATION MSHA-APPROVED MULTI GAS MONITORS Part No. 45 42 294 45 42 295 45 42 296 45 42 297 45 42 298 45 42 299 45 42 301 45 42 305 45 42 307 45 42 309 45 42 311 Part No. Dräger X-am® 5000 Dräger X-am® 5000, CH4, O2, CO, NO2, NiMH Batt Kit 45 43 923 No additional sensors can be selected with this configuration Dräger X-am® 5000, CH4, NiMH Batt Kit 45 43 925 Choose up to 3 additional electrochemical sensors from the Installed Sensor section below Dräger X-am® 5000, CH4, O2, NiMH Batt Kit 45 43 926 Choose up to 2 additional electrochemical sensors from the Installed Sensor section below Dräger X-am® 5000, CH4, O2, CO NiMH Batt Kit 45 43 927 Choose 1 additional electrochemical sensor from Installed Sensor section below Dräger X-am® 5000, CH4, O2, H2S NiMH Batt Kit 45 43 928 Choose 1 additional electrochemical sensor from Installed Sensor section below Dräger X-am® 5000, CH4, O2, CO2, H2S NiMH Batt Kit 45 43 929 No additional sensors can be selected with this configuration Dräger X-am® 5000, CH4, O2, Dual CO/H2S NiMH Batt Kit 45 43 930 Choose 1 additional electrochemical sensor from Installed Sensor section below Dräger X-am® 5000, CH4, O2, CO, CO-HC NiMH Batt Kit 45 43 931 No additional sensors can be selected with this configuration Dräger X-am® 5000, CH4, O2, CO, CO-HC, NO2 NiMH Batt Kit 45 43 933 No additional sensors can be selected with this configuration Dräger X-am® 5000 HC, CH4, O2, w/ NiMH & CHRG, MSHA 45 43 978 Dräger X-am® 5000 HC, CH4, w/ NiMH & CHRG, MSHA 45 43 979 Dräger X-am® 5000 HC, CH4, w/ NiMH & CHRG, PUMP, MSHA 45 43 980 Dräger X-am® 5000 HC, CH4, O2, w/ NiMH & CHRG, PUMP, MSHA 45 43 981 KIT, MSHA, PX2 PUMP w/ adapter for Dräger X-am® 125 45 43 982 MSHA PUMP POUCH 45 43 985 Not all products, features, or services are for sale in all countries. Mentioned Trademarks are only registered in certain countries and not necessarily in the country in which this material is released. Go to www.draeger.com/trademarks to find the current status. CORPORATE HEADQUARTERS Drägerwerk AG & Co. KGaA Moislinger Allee 53–55 23558 Lübeck, Germany www.draeger.com Customer Service: USA +1 800-4DRAGER (+1 800-437-2437) CANADA +1 877-DRAGER1 (+1 877-372-4371) Technical Service: USA +1 800-4DRAGER (+1 800-437-2437) Locate your Regional Sales Representative at: www.draeger.com/contact 90 72 451 | 16.12-4 | HQ | PP | Subject to modifications | © 2016 Drägerwerk AG & Co. KGaA Dräger X-am® 2500 Dräger X-am® 2500, Ex, O2, CO, H2S Alk Batt, MSHA Dräger X-am® 2500, Ex, O2, CO, H2S NiMH Batt, MSHA Dräger X-am® 2500, Ex, O2, H2S, Alk Batt, MSHA Dräger X-am® 2500, Ex, O2, H2S, NiMH Batt, MSHA Dräger X-am® 2500, Ex, O2, CO, Alk Batt, MSHA Dräger X-am® 2500, Ex, O2, CO, NiMH Batt, MSHA Dräger X-am® 2500, Ex, NiMH Batt, MSHA Dräger X-am® 2500, Ex, O2, CO, NiMH, MSHA,QTY 6, no chrgs Dräger X-am® 2500, Ex, O2, CO, NiMH, MSHA, w/ charger Dräger X-am® 2500, O2, SO2, NiMH, w/ charger Dräger X-am® 2500, CH4, O2, CO, NO2, MSHA, w/ charger