Preview only show first 10 pages with watermark. For full document please download

Mtda60a Series 60w Desktop Power Supply For It

   EMBED


Share

Transcript

MTDA60A SERIES 60W Desktop Power Supply for I.T. Equipment       1 Year Warranty Wide Input Voltage 90 to 264 VAC, 47 to 63Hz IEC-320-C14 Input Inlet Output Voltage Available From 12VDC Thru 48VDC Single Output Class I Insulation Energy Star 2.0, CEC V, and RoHS compliance Approvals: Single Output Product Number Output Voltage Max. Output Current Total Regulation Maximum Output Power 5.00 ~ 4.61 A 4.61 ~ 3.75 A 3.75 ~ 2.85 A 2.85 ~ 2.22 A 2.22 ~ 1.81 A 1.81 ~ 1.50 A 1.50 ~ 1.25 A 5% 5% 5% 3% 3% 3% 3% 60W 60W 60W 60W 60W 60W 60W MTDA60A-S05 12 ~ 13 VDC MTDA60A-S06 13 ~ 16 VDC MTDA60A-S07 16 ~ 21 VDC MTDA60A-S08 21 ~ 27 VDC MTDA60A-S09 27 ~ 33 VDC MTDA60A-S10 33 ~ 40 VDC MTDA60A-S11 40 ~ 48 VDC Total Regulation is conditioned by below configuration (S05~S07: AWG16/4FT output cable) (S08~S09: AWG18/4FT output cable) (S10~S11: AWG20/4FT output cable) Electrical Characteristics Parameter Input Voltage Input Frequency Output Power Range Input Current (Low Line) Input Current (High Line) High Line Inrush Current Efficiency Line Regulation Load Regulation Over Current Protection Transient Response Hold-Up Time Start Up Time Ripple & Noise (Peak to Peak) Safety Ground Leakage Current Temperature Coefficient No-load Power Consumption Test Conditions Universal Input Voltage Operating Voltage Vin=100 to 240VAC Io=Full load, Vin=115VAC Io=Full load, Vin=230VAC Io=Full load, 25°C, Cool start, Vin=230VAC Io=Full Load, Vin=230VAC Io=Full Load Vin=230VAC Min. Typ. 100 90 47 0 Io=Full Load, Vin=240VAC All output No load, Vin=240VAC Unit 240 264 63 60 1.6 0.7 105 VAC VAC Hz W A A A % % % % mS mS S % mA %/°C W 87 0.5 3 1 5 150 4 2 0.5 0.5 3 1 0.75 0.04 0.5 110 Io=Full Load to Half Load, Vin=100VAC Io=Full Load, Vin=230VAC Io=Full Load, Vin=100VAC Full Load, Vin=90VAC Max. 10 -0.04 0.4 Conditions Parameter Test Conditions Operating Temperature Storage Temperature Operating Humidity Storage Humidity Operating Temperature at 25°C, Calculated per MIL-HDBK-217F Min. Typ. Max. Unit 0 -40 0 0 0.1M 40 70 85 95 75 °C °C % % Hrs Min. Unit 4242 2121 50 B B VDC VDC MΩ CLASS CLASS Approvals and Compliance Parameter Test Conditions Dielectric Withstanding Voltage for Primary to secondary Dielectric Withstanding Voltage for Primary to Ground Isolation Resistance EMI requirements for CISPR-22 EMI requirements for FCC PART-15 Primary to secondary Primary to ground Test Voltage=500VDC Vin=220VAC Vin=110VAC Mechanical and PIN out Note: 1. Dimensions are shown in mm. 2. Weight: 340g approx. 3. Optional output connector.