MULTI-HEAT AUTOMATIC STOKER BOILER FOR WOOD PELLETS OR CORN
Easy to operate
Environmentally Friendly heating
Unusually high efficiency
Certified in accordance with DS/EN ISO 9001
TA R M U S A I N C www.pelletboiler.com
TARM Multi-Heat
3/8/07
6:36 PM
Page 2
Make yourself independent of oil price increases and fossil fuels:
Fully Automatic Stoker Boiler With Hopper The HS-TARM Multi-Heat boiler is especially well suited for effective and environmentally friendly firing with biomass such as wood pellets and corn.
Significant savings on your heat bills The HS-TARM Multi-Heat boiler is a great choice for sustainable energy heating of homes and light industrial, commercial, and institutional buildings. Firing with wood pellets or corn in the MultiHeat can achieve considerable savings in comparison to fossil fuels. Such savings depend, among other things, on the type of fuel, purchase prices and the annual efficiency of the old boiler. Furthermore, many local governments, possibly yours, are giving grants or subsidies for the installation of Multi-Heat boilers using renewable energy fuel.
Construction and function The construction of the boiler gives high
operational security, significant durability, excellent economy, environmentally friendly combustion and simple operation. Depending on the heating requirement, the feeder mechanism automatically feeds the appropriate quantity of fuel into the combustion chamber. The built-in blower produces a precise mixture of primary and secondary air, resulting in a very high efficiency. The temperature is regulated by a two-step control. This means that the boiler operates at full output until the set temperature is close to being achieved. Then the control switches over to reduced output and continues at this rate. If the boiler temperature drops slightly below the set temperature again, the control will once again switch over to full output. This control ensures constant heat. For best efficiency, the boiler size and adjustment of the output ought to be only slightly greater than the buildings requirement.
The hopper must typically be filled up once or twice a week during cold weather. However this will depend on the heat requirement, hopper size and fuel. The possibility of automatic feeding of fuel from a large external bin or silo is also available. Ash is removed as required.
A heat storage tank is unnecessary The boiler output can be regulated from 100% down to 30% during continuous operation and, in pilot/standby mode, as low as approx. 3412 BTU/hr (1 KW). In order to maintain the boiler outside the heating season, at least one hot water tank 25-80 gal. as well as 1-2 radiators or under-floor heating must be connected (open), but as such no large heat storage tank is necessary. In order to obtain the best possible yield as far as the firing economy, the environment and comfort is concerned, it is important that the boiler is correctly installed and adjusted.
Some key advantages • • •
•
• • Multi-Heat: Fully automatic automatic stoker stokerboiler boilerwith withhopper hopper Multi-Heat:Fully
About the Manufacturer HS-TARM Multi-Heat boilers are manufactured by BAXI/AS. BAXI A/S has grown to be Denmark’s leading producer of central heating systems used to supply the space heating and domestic hot water needs of private dwellings. The production of BAXI A/S products is based on strict requirements for material and technical construction design. The
•
For economical, environmentally friendly combustion of fuels such as wood pellets and corn. Constant heating gives optimum building comfort. Very high efficiency, up to 89-91%. Multifunctional digital control provides simple operation with continuously variable heat output from 30-100%. The boiler does not require a heat storage tank. Exposed parts of the combustion chamber are constructed in acid-proof, stainless steel (AISI 316L). Remaining steel plates exposed to flue gas are • inch thick. Automatic shut-off to prevent fuel hopper burn back. Delivered completely assembled and ready - mounted with hopper, casing and control. Automated refilling of hopper available as optional extra.
Multi-Heat boilers have been tested and certified by safety, air quality, and consumer organizations for use in Europe, the USA, and Canada. It has always been a part of the company’s objective that the products from BAXI A/S should satisfy the users requirements regarding both the functional quality and good taste. Currently, BAXI A/S carries out quality control in accordance with DS/ENISO-9001, which is an extensive, internationally recognized
standard for quality control systems. Reliability of operation, unique firing economy and, not least, consideration of the environment are factors which have been instrumental in placing BAXI A/S as an internationally recognized supplier of central heating boilers. To maintain its leadership position, BAXI A/S constantly looks to develop and improve its products. There is never a compromise of principle, solid quality, high output or timeless design.
TARM Multi-Heat
3/6/07
7:00 PM
Page 3
Solid quality Quality M Solid
Flue gas-affected, Flue-gas affected, water-cooled water-cooled steel plates in thein interior of theof boiler steel plates the interior the are 6 mm thick especially exposed parts boiler are and 6 mm thick and of the combustion especially exposedchamber parts of are the of acidproof stainless steel. are of acidcombustion chamber proof stainlesless steel.
Controlpanel panel M Control to place placeininthe theroom room Easy to M Easy whereititisistotobebesetset where upup
The flue-gas flue-gas exit exit isisfrom fromthe thetop top of the The boiler and can easily ledbe toled the of the boiler andbecan easily to the chimney. The doors are re- and chimney. The doors are reversible versible and cantowards be opened can be opened the left or the towards right. the left or the right.
Thisisisplaced placedabove abovethe thedoors doorsand is This and is operated the front. operated from thefrom front.
Cleaningthe theboiler boiler M Cleaning
Removing Removingash ashand andcleaning cleaningthe thefire fire tubes can easily be done tubes can easily be carried out from from the front. the front.
Multi-Heat M MULTI-HEAT
Can Canbe besupplied suppliedwith withvarious varioussizes sizesof fuel hoppers (see(see technical details). The of fuel hoppers technical door for the is reversible details). Thehopper door for the hoppersoisthat itreversible is possible fillitupisfuel eithertofrom sotothat possible fill the or from thethe right or left side. up back, fuel either from back, or from the right or left side.
Wood pellets, pellets, M Wood and and corn corn
These These are are renewable, renewable, environmentally environmentally friendly, often fuels friendly, inexpensive inexpensive and domestic domestic fuels which can replace which can replace imported, more imported, expensive and environexpensive more and environmentally strainmentally ing fossilstraining fuels. fossil fuels (oil).
MULTI-HEAT A boiler for the future.
TARM Multi-Heat
3/6/07
10:22 PM
Page 4
Wood from Wood pellets are produced W dpellets ll are produced d as by-products d as bby-products d the wood ffrom industry, e.g. from chips and sawdust which are pressed the wood industry, e.g. from chips and sawdust into pellets. which pressed into the pellets. lbs.ofof 18 lbs. ofare wood pellets can substitute approx. 18 1 gallon wood oil*. pellets substitute approx. 1 gallon heating (2.2can kilograms of wood pellets can substitu-of te approx.oil*. 1 litre(2.2 of heating oil). of wood pellets can heating kilograms substitute approx. 1 liter of heating oil). MULTI-HEAT is delivered as an as assembled unit. Theunit. The Multi-Heat is delivered an assembled hopper is fastened with bolts. Thebolts. boiler and hopper The hopper is fastened with Thethe boiler and can be separated so that internal transport is made easier. the hopper can be separated so that internal transport is made easier.
The gear motor draws or turns the worm conveyor/auger The gear motor turns the conveyor/auger round and feeds the fuel into theworm combustion chamber at andproper feedsrate. the fuel into the combustion chamber the
at the proper rate.
The stokerboiler boileris is delivered delivered with control The stoker withananelectronic electronic control unitwhich which regulates regulates the of fuel and air forair the for com-the unit theflow flow of fuel and bustion. Continuously variable output can be set from combustion. Continuously variable output can be set 100% to 30% during continuous operation. When the set from 100-30%has during continuous operation. the temperature been achieved, the blower mustWhen be setswitched temperature been will achieved, the to blower will off andhas the control switch over firing at switch offIn and the control will switch overbyto intervals. the interval setting, the fire is maintained filling a small quantity of fuel at long intervals “standby.” In the “standby” setting, the fireinto is the maincombustion chamber and by connecting the blower tained by feeding a small quantity of fuel at long interbriefly. vals into the combustion chamber and by running the Furthermore, the control makes it possible to produce diblower briefly. of the boiler temperature, return temperagital readings Furthermore, thetemperature. control makes it possible to produce ture and smoke digital readings of the boiler temperature, return temperature and smoke temperature.
Behind the insulated doors, it is possible to see Behind theheavily heavily insulated doors, it is possible horizontal heat exchange with turbulators retothesee the horizontal heattubes exchanger tubes or with tarders designed for maximum heat exchange efficiency. turbulators designed heat exchange Behind the lowest door,for the maximum combustion chamber with efficiency. thezone lowest the ceramic Behind combustion can bedoor, seen. the combusThere is plenty of roomthe forceramic cleaning and removing ash. tion chamber with combustion zone can be seen. There is plenty of room for quick, easy cleaning and ash removal.
Corn, for example fromfrom fallow fields or set-asideset-aside land Corn, example fallow fields Corn, for for example fallow fields or or set-aside set-aside (energy crops) can wellfrom be used as fuel. land crops), is anapprox. excellent biomass (energy crops)can well 1begallon used as fuel. fuel. 21 lbs.(energy of corn can substitute of heating oil*. (2.5 kilograms of grain/corn substitute approx. 21 lbs. of corn corn can substitutecanapprox. 1 gallon gallon of lbs.of approx.1 1heating litre of heating oil*. oil). can (2.5 kilograms of grain/corn can Corn can form clinker which must be removed from the substitute chamber approx. as 1 required. liter oil). litre of of heating heating oil). worm combustion The co-delivered Corn can form clinkers which must beofremoved conveyor extension must be fitted in the event corn stoking. from the combustion chamber as required. The The
The andcover steadyofcover thehopper fuel hopper closes Thesturdy sturdy the of fuel closes tightly tightly so that burn back is avoided.
so that burn-back is avoided.
co-delivered fittedbreak to help auger extensionextension must be must fitted be to help up break up corn clinkers. corn clinkers.
BAXI Feeding Unit. can obtain With External the Automatic FeedYou Device. Youmaximum can obtain operating comforts and time-saving through installation maximum operating comfort and time-saving of a BAXI External Feeding Unit for wood pellets and through installation an Automatic Feed Device corn. By means of a gearof motor incl. a worm conveyor in afor pipe system the solid fuel is automatically conveyed wood pellets and corn. A grain type auger can from a siloto to automatically the hopper of thetransfer boiler, if required. be used the fuel Please from an see special leaflet for further information.
When plate between the boilerthe and boiler the hop-and Whenthe thecovering side access cover between per is removed, it is possible to see the ventilator which the hopper removed, it is possible ensures the airis necessary for combustion. Here,to it issee alsothe blower towhich airfor necessary for compossible see theprovides thermostatthe valve the sprinkler bustion. Here,retrograde it is alsocombustion. possible toUppermost, see the thermowhich prevents it is possible to see opening for easy accessprevents for cleaning stat valve forthethe sprinkler which retrothe fluecombustion. chamber. grade Uppermost, it is possible to see
external bin or silo to the boilerʼs hopper.
* The calorific values indicated are for guidance only since the comparison is values dependent on several heat indicated arecondifor guidguidb*The Theequivalent equivalent heat valuesindicated are for tions,only such as the composition and water of on ance since the comparison comparison is contents dependent ance only since the is dependent on the bio-fuel. several conditions, conditions, such such as as the the composition composition and and several water contents contents of of the the biomass. biomass. water
the access cover for cleaning the flue chamber. Tarm USA, Inc 5 Main Street Lyme, NH 03768
Ball Valve
Drawn by: TSP Checked by: LGN
Symbol Key
Tarm Piping Layout Concept Diagram
Check Valve
Multi-Heat Boiler Installation with Circulators
SCALE
Date
DWG NO
6-21-2006 N/A
MH-1 SHEET
Weighted Check Valve
REV
3
Pressure Relief Valve
1 OF 1
Motorized Zone Valve Pressure Reducing Valve Differential Pressure Bypass
Air Separator Circulator (w/isolation flanges) Burn Back Flood Water Pressure Tank Contents of water-Tank 5 Gal Pressure Max.-145 psi
Heating Zone (typical)
Boiler Drain Union Backflow Preventer Termovar Valve
Feed
P-1
P-2
P-3
MULTI-HEAT can be installed as shown in this diagram.
C-1 1¼" Feed
TV-1 1¼" Pressure/Temperature Gauge
1
3 2 1¼"
RV-1
Draft stabiliser - extra equipment. Strong wind or a very stabilizer - extraequipment. equipment.Strong Strong wind wind or or a Draft stabilizer-extra high chimney can cause excessive and fluctuating chimvery high Inchimney cause excessive draft. ney draft. such cases,can the solution is building in a draftIn such cases,since the the solution is building in a draft stabiliser, best combustion is achieved withstabia suitable stable chimney draft 0.04-0.10with inches Theand best combustion is of achieved a suitlizer. water column. able and stable chimney draft of 0.04-0.10 inches water column.
SYR-Valve
It is possible to install the Multi-Heat with either closed or open expansion.
Notes: TV-1 Valve-Termovar 4440 Thermostatic Valve or Equivalent.
Overheat Cooling Coil
SYR-Valve Burn Back Piping
MULTI-HEAT can this diagram. TheThe separate hot hot water tanktank mustmust be connected prior to the to the MULTI-HEAT can be beinstalled installedasasshown showninin this diagram. separate water be connected prior shuntvalve. valve. By By means means of intervals outside of of thethe shunt of correct correct adjustment, adjustment,this thisinstallation installationwill willgive givethe thepossibility possibilityofoffiring firingatat intervals outside firing season. It is possibleMulti-Heat to install Boiler the MULTI-HEAT with either closed or open expansion. heating season. It is possible to install the Multi-Heat with either closed or open expansion. Drain
Drain
Note: This is only a concept drawing. Final design, installation and code compliance details are the responsibility of the designer/installer of the system.
4
TARM Multi-Heat
3/1/07
9:29 PM
Page 5
Technical Data
Seen from the front Seen from the side
Seen from above
MULTI-HEAT 1. 9. 10. 18. 19. 20. H1 H2 L1 L2 L3 L4 L5 L6 L7 B4 B4 B4 B4 B1 B2 B3 B5
Boiler control Flue pipe branch, external diameter Hopper door, reversible Flow and expansion Return Connection of retrograde fire safety sprinkler Height Height Depth of boiler Measurement Hopper depth Measurement Measurement Measurement Measurement Hopper width, vol. cu.ft. 7 (200 litres) Hopper width, vol. cu.ft. 121/2 (350 litres) Hopper width, vol. cu.ft. 123/4 (360 litres) Hopper width, vol. cu.ft. 21 (600 litres) Measurement Measurement Boiler width Measurement Gear motor, effect Blower motor Electricity consumption Electricity connection / circuit breaker 240 V - 60 Hz / 15 A
Type designation MULTI-HEAT 1.5 - 200 MULTI-HEAT 1.5 - 350 MULTI-HEAT 2.5 - 360 MULTI-HEAT 2.5 - 600 MULTI-HEAT 2.5 - 360 MULTI-HEAT 2.5 - 600 MULTI-HEAT 4.0 - 360 MULTI-HEAT 4.0 - 600 MULTI-HEAT 4.0 - 360 MULTI-HEAT 4.0 - 600
inch (mm) inches inches inches inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) inch (mm) W W W
Model 1.5 X 5 1/8 (130) X 1 1 1/2 3 39 /4 (1010) 45 7/8 (1165) 23 (581) 7 3/4 (197) 19 1/2 (497) 56 1/2 (1435) 14 1/5 (360) 5 (125) 6 1/2 (165) 19 3/4 (504) 35 3/4 (910) – – 10 (252) 10 (252) 19 3/4 (504) 8 1/2 (215) 120 90 300 X
Output Hoppersize BTU/hr (kW) cu.ft. (liter) 51,200 51,200 85,300 85,300 85,300 85,300 146,700 146,700 146,700 146,700
(15) (15) (25) (25) (25) (25) (43) (43) (43) (43)
7 12 1/2 12 3/4 21 12 3/4 21 12 3/4 21 12 3/4 21
(200) (350) (360) (600) (360) (600) (360) (600) (360) (600)
Model 2.5 X 5 7/8 (150) X 1 1 1/2 3 50 /8 (1280) 58 (1475) 23 (585) 8 1/2 (217) 24 1/4 (615) 62 1/2 (1578) 11 1/2 (294) 5 (125) 9 3/4 (248) – – 23 5/8 (600) 39 1/2 (1000) 11 7/8 (300) 11 7/8 (300) 23 5/8 (600) 8 7/8 (225) 370 90 460 X
Fuel Wood pellets Wood pellets Wood pellets Wood pellets corn corn Wood pellets Wood pellets corn corn
Model 4.0 X 5 7/8 (150) X 1 1 1/2 3 50 /8 (1280) 58 (1475) 27 1/2 (700) 8 1/2 (217) 24 1/4 (615) 66 2/3 (1693) 15 7/8 (403) 5 (125) 9 2/3 (245) – – 23 5/8 (600) 39 1/2 (1000) 11 7/8 (300) 11 7/8 (300) 23 5/8 (600) 8 7/8 (225) 370 90 460 X
Weight lbs (kg) 750 849 1169 1389 1279 1500 1279 1500 1279 1500
(340) (385) (530) (630) (580) (680) (580) (680) (580) (680)
TARM Multi-Heat
3/6/07
7:23 PM
Page 6
Equipment Equipmentpackage: package:
Complete stokerboiler boiler consisting consistingof: of: Complete stoker •• Boiler Boiler •• Casing Casingwith withinsulation insulation •• Fuel Fuelhopper hopper •• Worm conveyor Worm conveyor •• Gear fuel Gearmotor motorfor forconveying conveying the the fuel •• Blower Blower •• Turbulators Turbulators •• Ceramic Ceramicinsert insert •• Boiler Boilercontrol control •• Micro-switch Micro-switchfor forhopper hopper •• Overheat Overheatcooling coolingcoil coil •• Pressure watersprinkling sprinkling Pressurevessel vesselset setfor for automatic automatic water •• Thermostatic cut-outasaswell wellasas Thermostaticretrograde retrogradecombustion combustion cut-out internalelectrical electrical installation installation and internal andcleaning cleaningtools tools
Extraaccessories: accessories: Extra
Shuntvalve valve •• Shunt Draftstabilizer stabilizerfor forchimney/boiler chimney/boiler flue •• Draft flue outlet outlet Automaticshunt shuntcontrol control •• Automatic AutomaticFeed FeedDevice Device •• Automatic
Fuel: Fuel: Suitable fuels:wood pellets and corn. Model 1.5 is princi-
Suitable fuels:wood pellets and corn. Model 1.5 is principally developed for firing with wood pellets. pally developed for firing with wood pellets.
Arrangement conditions:
Arrangement conditions: HS-Tarm Multi-Heat must be set-up in a room with suffi-
HS-Tarm Multi-Heat be set-up a room must with sufficient supply of air. Themust magnitude of theinair-intake cient supplyto of Thediameter magnitude the air-intake correspond theair. inside of theofchimney, howevermust at least 31 in² (0.02 correspond to them².) inside diameter of the chimney, however • least The 31 chimney draftm*.) must be 0.04-0.1 inch WC (1.0-2.5 at in* (0.02 mm water column). • The chimney draft must be 0.04-0.1 inch WC (1.0-2.5 • mm Local building code regulations in the area of the installawater column). tion must be followed. • Local building code regulations in the area of the installa• tion Request, if necessary, must be followed.further installation and operational guidelines withmodels further information USA. • ASME stamped required byfrom someTarm states and building codes. Check with your local building inspector. •Warranty: Request, if necessary, further installation and operational Fully effective warranty in accordance withTarm warranty guidelines with furtherasinformation from USA. conditions from Tarm USA.
Warranty:
Fully effective warranty as in accordance with warranty Our offering of solid fuel boilers also conditions from Tarm USA.
comprises the following:
Our offeringMKIIof solid fuel also • MB-SOLO natural draftboilers boilers for wood and comprises the following: coal. •• SOLO boilers. SOLOPLUS-wood PLUS-woodgasification gasification boilers. EXCELMULTI-FUEL-wood MULTI-FUEL-wood gasification gasification boilers •• EXCEL boilerswith with gasback-up back-up fuel. oiloilororgas NB: Type HS-Tarm Multi-Heat is supplied without built-in hot water NB: Type HS-Tarm Multi-Heat is supplied without built-in supply.
hot water supply.
** Least Leastrecommended recommendedstand-by stand-byoutput outputwhile whilstfiring firinginin“standby” “standby”soso ** that the the fire fire can can be be maintained. maintained. that ***This is the minimum smoke temperature which is recommended ***This is the output. minimum recommended for minimum Thissmoke smoketemperature temperaturewhich is tooislow for normal for minimum This smoke temperature is too alow for normal operation output. with ordinary chimneys. We consider smoke temperature operation with ordinary chimneys. considerfor a smoke temperature of 212°F (100°C) to be the absoluteWe minimum ordinary chimneys. of 212°F (100°C) to be the absolute minimum for ordinary chimneys. We have therefore built in an alarm on the smoke temperature at 212° We have therefore built in an alarm on the smoke temperature at 212°F F (100°C) . This is to say that if the smoke temperature has been (100°C) . This (100°C) is to say for thathalf if the temperature been below below 212°F an smoke hour, the boiler willhas stop. This alarm (100°C) also ensures against continually filling withThis fuelalarm if the also fire 212°F for half an hour, the boiler willupstop. goes out. ensures against continually filling up with fuel if the fire goes out.
Technical data: MULTI-HEAT
Model 1.5
Model 2.5
Model 4.0
Operating temperature °F (°C) 140-185 (60-85) 140-185 (60-85) 140-185 (60-85) Output (nominal) with wood pellets BTU/hr (kW) 51200 (15) 85300 (25) 146700 (43) Output (nominal) with corn BTU/hr (kW) N/A 85300 (25) 146700 (43) Output (minimum) with wood pellets BTU/hr (kW) 15700 (4.6) 25600 (7.5) 40950 (12) Output (minimum) with corn BTU/hr (kW) N/A 25600 (7.5) 40950 (12) Output (stand-by) recommended **approx. BTU/hr (kW) 1700 (0.5) 2700 (0.8) 3300 (1.0) Smoke temperature at nom. output, wood pellets °F (°C) 302 (150) 356 (180) 356 (180) Smoke temperature at nom. output, corn °F (°C) – 392 (200) 392 (200) Smoke temperature at min. output, wood pellets *** °F (°C) 212 (100) 230 (110) 230 (110) Smoke temperature at min. output, corn – 239 (115) 239 (115) °F (°C)) Fuel consumption at nom. output, wood pellets lbs/hr (kg/h) 7.5 (3.4) 12.6 (5.7) 22 (10) Fuel consumption at nom. output, corn lbs/hr (kg/h) N/A 13.2 (6.0) 24.3 (11) Test pressure, boiler PSI (bar) 58 (4.0) 58 (4.0) 58 (4.0) Approved fuel types: 1/4-3/4 (5-20) 1/4-3/4 (5-20) 1/4-3/4 (5-20) wood pellets, approx. 8% of moisture inch (mm) corn, approx. 15% of moisture – YES YES
Installation data: MULTI-HEAT A B C D
Depth - total Width - boiler Height Width - hopper *
inch (mm) inch (mm) inch (mm) inch (mm)
Hopper volume
ft 3 (litre)
Height to Flue collar inch (mm) Flue pipe branch - external diameter inch (mm) Weight - empty lbs (kg) Water contents
Us gal. (liter)
Model 1.5
Model 2.5
Model 4.0
56 1/2 (1435) 19 3/4 (504) 45 7/8 (1165) 19 3/4/35 1/3 (504/904) 7/12 1/2 (200/350) 43 3/4 (1110)
62 1/8 (1578) 23 5/8 (600) 58 1/8 (1475) 23 3/8/39 1/2 (600/1000) 12 1/4/21 (360/600) 57 1/4 (1455)
66 5/8 (1693) 23 5/8 (600) 58 1/8 (1475) 23 3/8/39 1/2 (600/1000) 12 1/4/21 (360/600) 57 1/4 (1455)
5 1/8 (130) 750/849 (340-385) 13 (50)
5 7/8 (150) 1 389 (530-630) 33 (125)
5 7/8 (150) 1279/1500 (580-680) 39 (150)
168/1
* Necessary door opening: Width D + 2 inch.
Sold by:
TA R M U S A I N C 5 Main Street, 5 Main Street,Lyme, Lyme,NH NH 03768 03768 Tel Tel 800-782-9927—Fax(603)785-4740 800-782-9927—Fax(603)785-4740
[email protected] [email protected] www.pelletboiler.com www.pelletboiler.com www.woodboilers.com www.woodboilers.com
Feb 2007