Preview only show first 10 pages with watermark. For full document please download

Multilink Power Source Catalog.indd

   EMBED


Share

Transcript

The Power Supply For Forward Thinking Engineers PATENTED Externally Located Input and Output Circuit Breakers The Only True UPS/Mission Critical Power Supply True UPS Mission Critical No transfer, No interruption Temperature-compensated four-stage charger 90V/75V/60V operation HMS RS485 LCD Display Universal input Battery temperature sensor The MP Plus power supply traces its roots to services started in 1998 with its forerunner, the MP True UPS. At that time, power supplies based on the true UPS concept constituted the largest trouble-free installations of any CATV / Broadband network power supply in the world. The key to part of this success is the universal input that allows this particular power supply to operate from a wide range of voltages. Consequently, line voltage spikes, sags and minor surges that occur daily on the AC utility lines are absorbed in the input circuits of the MP Plus power supply. If a brownout, blackout or momentary loss of AC power occurs, the transfer to the battery backup inverter is seamless with absolutely no power anomalies being reflected to the load. Circuit topology within the MP Plus series provides a true UPS product suitable for today’s mission-critical applications, offering the best and most reliable back-up source for services such as VoIP and others. Standby power supplies simply cannot provide the quality of power and the ongoing reliability offered in the MP Plus True UPS power supply. US Patent # 5,994,793 & US 6,268,665 B1 20 Multilink Broadband Network Powering Products For Outside Plant MULTILINK POWER SOURCE CATALOG.iSec1:20 Sec1:20 6/6/2007 12:44:49 P . MP Plus Power Supplies . VoIP Ready Specifications MP Plus 900, 1350-120, 1350-240 Size Weight Environmental MP Plus 900 MP Plus 1350 16”W x 8.625”H x 12”D MP Plus 900 & 1350 65/72 lbs -40 to 60C 95% RH non condensing Protection I-Track electronic current limit and output breakers battery circuit breaker Cabinet Lights 4 pin mini mate-n-lock Temperature Sensor 2 pin mini mate-n-lock Test Jacks Output voltage (TRMS) Output current (TRMS) Battery String Voltage Low Battery cut off 36V System, 31.5V(1.75 VPC) 48V System, 42(1.75 VPC) Battery Acceptance 36V System, 37VDC TYP 48V System, 49 VDC TYP Low Line Reject MP Plus 900 MP Plus 1350 - 120 MP Plus 1350 - 240 Status Monitor HMS RS485 80 VAC 95 VAC 170 VAC New Features: - HMS RS485 serial status monitoring - Compatible with StatTrak/Tollgrade/Cheetah/Electroline - Electronically controlled output current protection, no Smart Breaker required - Smaller physical package, the MP Plus is 1/2” shallower than the previous supply (12” X 16.25” X 8.625”) - Redesigned top cover to reduce water migration - Externally located input and output circuit breakers - Output voltage tap is accessible without removing front panel The New Serial Status Monitoring Port Monitors: - Output #1 and output #2 current - Output #1 voltage - Input voltage - Input current - Battery string voltage - Major alarm Minor alarm Inverter status Last test status Tamper switch Test start/stop All of this is monitored with no external hardware, such as line sense transformers or output voltage wire harnesses. This reduces the complexity of installation and reduces clutter in the enclosure. The Power Supply to Transponder Interface Bus (PSTIB) is designed to allow up to 32 devices. Locations with multiple power supplies can use a single transponder to monitor all of the power supplies. To monitor individual battery voltages, Mulitlink is offering the MPHMS Battery Monitor. This device is capable of monitoring up to 16 batteries and communicates to the HMS transponder over the same PSTIB as the power supply. Optional BluetoothTM wireless local access to power supply performance and status up to 100’ away. Bluetooth is a registered trademark of Bluetooth SIG, Inc., USA Multilink Broadband Network Powering Products For Outside Plant MULTILINK POWER SOURCE CATALOG.iSec1:21 Sec1:21 21 6/6/2007 12:44:51 P MULTIPOWER MP Plus Series True UPS/Mission Critical VOIP Ready For CATV Broadband Networks PATENTED Electronically Controlled Output Current Protection “Self Resets” Dual Outputs Can Run 90 And 60 Volt Plant On Each Output Easy Access Output Selector No Dip Switches To Mess With Universal Input Offers A Wide Range Of Input Voltage And Frequency Dual Heat Sinks LCD Display Standard Battery Connector Circuit Breakers No Fuses To Replace HMS RS485 Serial Status Monitoring Size (12” x 16.25” x 8.625”) Fits most power supply cabinets US Patent # 5,994,793, US Patent # US 6,268,665 B1, US Patent # 6,932,443 22 Multilink Broadband Network Powering Products For Outside Plant MULTILINK POWER SOURCE CATALOG.iSec1:22 Sec1:22 6/6/2007 12:44:52 P . MP Plus Power Supplies . Nominal Specifications For MP 900 & 1350 True UPS Power Supplies Part # Model Description Nominal Input Voltage VAC Input Frequency Hz Output Voltage VAC Output Current A Max Output Power VA Battery Voltage VDC Approximate Wt. lbs/kg 017-022-20 MP PLUS 900-120-36 W/HMS 120 47-63 60/75/90 15/12/10 900 36 60/27.2 017-022-21 MP PLUS 900-240-36 W/HMS 240 47-63 60/75/90 15/12/10 900 36 60/27.2 017-022-22 MP PLUS 900-120-48 W/HMS 120 47-63 60/75/90 15/12/10 900 48 60/27.2 017-022-23 MP PLUS 900-240-48 W/HMS 240 47-63 60/75/90 15/12/10 900 48 60/27.2 017-022-24 MP PLUS 900-120-36 WO/HMS 120 47-63 60/75/90 15/12/10 900 36 60/27.2 017-022-25 MP PLUS 900-240-36 WO/HMS 240 47-63 60/75/90 15/12/10 900 36 60/27.2 017-022-26 MP PLUS 900-120-48 WO/HMS 120 47-63 60/75/90 15/12/10 900 48 60/27.2 017-022-27 MP PLUS 900-240-48 WO/HMS 240 47-63 60/75/90 15/12/10 900 48 60/27.2 017-023-20 MP PLUS 1350-120-36 W/HMS 120 47-63 60/75/90 22/18/15 1350 36 72/32.7 017-023-21 MP PLUS 1350-240-36 W/HMS 240 47-63 60/75/90 22/18/15 1350 36 72/32.7 72/32.7 017-023-22 MP PLUS 1350-120-48 W/HMS 120 47-63 60/75/90 22/18/15 1350 48 017-023-23 MP PLUS 1350-240-48 W/HMS 240 47-63 60/75/90 22/18/15 1350 48 72/32.7 017-023-24 MP PLUS 1350-120-36 W0/HMS 120 47-63 60/75/90 22/18/15 1350 36 72/32.7 017-023-25 MP PLUS 1350-240-36 W0/HMS 240 47-63 60/75/90 22/18/15 1350 36 72/32.7 017-023-26 MP PLUS 1350-120-48 W0/HMS 120 47-63 60/75/90 22/18/15 1350 48 72/32.7 017-023-27 MP PLUS 1350-240-48 W0/HMS 240 47-63 60/75/90 22/18/15 1350 48 72/32.7 017-038-20 MP PLUS LCD 1350-120-36 120 47-63 60/75/90 22/18/15 1350 36 72/32.7 True UPS/Mission Critical Power Supply PENDING AGENCY APPROVAL Multilink Broadband Network Powering Products For Outside Plant MULTILINK POWER SOURCE CATALOG.iSec1:23 Sec1:23 23 6/6/2007 12:44:53 P How to tell the difference between True UPS and Cable UPS/Standby Power Rides Through Transients & Noise 65z to 65Hz Line Conditioning High Volume Boast 120V-35% to +120% High Isolation 2 10 ms 20.0 V True UPS 3 10 ms 20.0 V Status Monitoring Interface Full 10A Charger At All Loads Standard Feature Simplified Controller 24 Multilink Broadband Network Powering Products For Outside Plant MULTILINK POWER SOURCE CATALOG.iSec1:24 Sec1:24 6/6/2007 12:44:55 P . CONFLUENT POWER. AC Converted To DC DC Converted To AC High Voltage Inverter Rectifier Soft Start-No Inrush Current Ferro Simultaneous Inverter Operation No Switching Output Battery Charger No Risk Battery & Inverter Test Low Voltage Boost Low Voltage Inverter No Cooling Fans Required Multilink Broadband Network Powering Products For Outside Plant MULTILINK POWER SOURCE CATALOG.iSec1:25 Sec1:25 25 6/6/2007 12:45:00 P