The Power Supply For Forward Thinking Engineers PATENTED
Externally Located Input and Output Circuit Breakers
The Only True UPS/Mission Critical Power Supply
True UPS Mission Critical No transfer, No interruption Temperature-compensated four-stage charger 90V/75V/60V operation
HMS RS485 LCD Display Universal input Battery temperature sensor
The MP Plus power supply traces its roots to services started in 1998 with its forerunner, the MP True UPS. At that time, power supplies based on the true UPS concept constituted the largest trouble-free installations of any CATV / Broadband network power supply in the world. The key to part of this success is the universal input that allows this particular power supply to operate from a wide range of voltages. Consequently, line voltage spikes, sags and minor surges that occur daily on the AC utility lines are absorbed in the input circuits of the MP Plus power supply. If a brownout, blackout or momentary loss of AC power occurs, the transfer to the battery backup inverter is seamless with absolutely no power anomalies being reflected to the load. Circuit topology within the MP Plus series provides a true UPS product suitable for today’s mission-critical applications, offering the best and most reliable back-up source for services such as VoIP and others. Standby power supplies simply cannot provide the quality of power and the ongoing reliability offered in the MP Plus True UPS power supply.
US Patent # 5,994,793 & US 6,268,665 B1
20 Multilink Broadband Network Powering Products For Outside Plant
MULTILINK POWER SOURCE CATALOG.iSec1:20 Sec1:20
6/6/2007 12:44:49 P
. MP Plus Power Supplies . VoIP Ready Specifications MP Plus 900, 1350-120, 1350-240 Size Weight Environmental
MP Plus 900 MP Plus 1350
16”W x 8.625”H x 12”D
MP Plus 900 & 1350
65/72 lbs
-40 to 60C 95% RH non condensing
Protection
I-Track electronic current limit and output breakers battery circuit breaker
Cabinet Lights
4 pin mini mate-n-lock
Temperature Sensor
2 pin mini mate-n-lock
Test Jacks
Output voltage (TRMS) Output current (TRMS) Battery String Voltage
Low Battery cut off
36V System, 31.5V(1.75 VPC) 48V System, 42(1.75 VPC)
Battery Acceptance
36V System, 37VDC TYP 48V System, 49 VDC TYP
Low Line Reject
MP Plus 900 MP Plus 1350 - 120 MP Plus 1350 - 240
Status Monitor
HMS RS485
80 VAC 95 VAC 170 VAC
New Features: - HMS RS485 serial status monitoring - Compatible with StatTrak/Tollgrade/Cheetah/Electroline - Electronically controlled output current protection, no Smart Breaker required - Smaller physical package, the MP Plus is 1/2” shallower than the previous supply (12” X 16.25” X 8.625”) - Redesigned top cover to reduce water migration - Externally located input and output circuit breakers - Output voltage tap is accessible without removing front panel
The New Serial Status Monitoring Port Monitors: - Output #1 and output #2 current - Output #1 voltage - Input voltage - Input current - Battery string voltage
-
Major alarm Minor alarm Inverter status Last test status Tamper switch Test start/stop
All of this is monitored with no external hardware, such as line sense transformers or output voltage wire harnesses. This reduces the complexity of installation and reduces clutter in the enclosure. The Power Supply to Transponder Interface Bus (PSTIB) is designed to allow up to 32 devices. Locations with multiple power supplies can use a single transponder to monitor all of the power supplies. To monitor individual battery voltages, Mulitlink is offering the MPHMS Battery Monitor. This device is capable of monitoring up to 16 batteries and communicates to the HMS transponder over the same PSTIB as the power supply.
Optional BluetoothTM wireless local access to power supply performance and status up to 100’ away. Bluetooth is a registered trademark of Bluetooth SIG, Inc., USA
Multilink Broadband Network Powering Products For Outside Plant
MULTILINK POWER SOURCE CATALOG.iSec1:21 Sec1:21
21
6/6/2007 12:44:51 P
MULTIPOWER MP Plus Series True UPS/Mission Critical VOIP Ready For CATV Broadband Networks PATENTED
Electronically Controlled Output Current Protection “Self Resets”
Dual Outputs Can Run 90 And 60 Volt Plant On Each Output
Easy Access Output Selector No Dip Switches To Mess With
Universal Input Offers A Wide Range Of Input Voltage And Frequency Dual Heat Sinks
LCD Display
Standard Battery Connector Circuit Breakers No Fuses To Replace
HMS RS485 Serial Status Monitoring
Size (12” x 16.25” x 8.625”) Fits most power supply cabinets
US Patent # 5,994,793, US Patent # US 6,268,665 B1, US Patent # 6,932,443
22 Multilink Broadband Network Powering Products For Outside Plant
MULTILINK POWER SOURCE CATALOG.iSec1:22 Sec1:22
6/6/2007 12:44:52 P
. MP Plus Power Supplies . Nominal Specifications For MP 900 & 1350 True UPS Power Supplies Part #
Model Description
Nominal Input Voltage VAC
Input Frequency Hz
Output Voltage VAC
Output Current A
Max Output Power VA
Battery Voltage VDC
Approximate Wt. lbs/kg
017-022-20
MP PLUS 900-120-36 W/HMS
120
47-63
60/75/90
15/12/10
900
36
60/27.2
017-022-21
MP PLUS 900-240-36 W/HMS
240
47-63
60/75/90
15/12/10
900
36
60/27.2
017-022-22
MP PLUS 900-120-48 W/HMS
120
47-63
60/75/90
15/12/10
900
48
60/27.2
017-022-23
MP PLUS 900-240-48 W/HMS
240
47-63
60/75/90
15/12/10
900
48
60/27.2
017-022-24
MP PLUS 900-120-36 WO/HMS
120
47-63
60/75/90
15/12/10
900
36
60/27.2
017-022-25
MP PLUS 900-240-36 WO/HMS
240
47-63
60/75/90
15/12/10
900
36
60/27.2
017-022-26
MP PLUS 900-120-48 WO/HMS
120
47-63
60/75/90
15/12/10
900
48
60/27.2
017-022-27
MP PLUS 900-240-48 WO/HMS
240
47-63
60/75/90
15/12/10
900
48
60/27.2
017-023-20
MP PLUS 1350-120-36 W/HMS
120
47-63
60/75/90
22/18/15
1350
36
72/32.7
017-023-21
MP PLUS 1350-240-36 W/HMS
240
47-63
60/75/90
22/18/15
1350
36
72/32.7 72/32.7
017-023-22
MP PLUS 1350-120-48 W/HMS
120
47-63
60/75/90
22/18/15
1350
48
017-023-23
MP PLUS 1350-240-48 W/HMS
240
47-63
60/75/90
22/18/15
1350
48
72/32.7
017-023-24
MP PLUS 1350-120-36 W0/HMS
120
47-63
60/75/90
22/18/15
1350
36
72/32.7
017-023-25
MP PLUS 1350-240-36 W0/HMS
240
47-63
60/75/90
22/18/15
1350
36
72/32.7
017-023-26
MP PLUS 1350-120-48 W0/HMS
120
47-63
60/75/90
22/18/15
1350
48
72/32.7
017-023-27
MP PLUS 1350-240-48 W0/HMS
240
47-63
60/75/90
22/18/15
1350
48
72/32.7
017-038-20
MP PLUS LCD 1350-120-36
120
47-63
60/75/90
22/18/15
1350
36
72/32.7
True UPS/Mission Critical Power Supply
PENDING AGENCY APPROVAL
Multilink Broadband Network Powering Products For Outside Plant
MULTILINK POWER SOURCE CATALOG.iSec1:23 Sec1:23
23
6/6/2007 12:44:53 P
How to tell the difference between True UPS and Cable UPS/Standby Power Rides Through Transients & Noise
65z to 65Hz
Line Conditioning
High Volume Boast
120V-35% to +120% High Isolation 2 10 ms 20.0 V
True UPS
3 10 ms 20.0 V
Status Monitoring Interface
Full 10A Charger At All Loads
Standard Feature
Simplified Controller
24 Multilink Broadband Network Powering Products For Outside Plant
MULTILINK POWER SOURCE CATALOG.iSec1:24 Sec1:24
6/6/2007 12:44:55 P
. CONFLUENT POWER.
AC Converted To DC
DC Converted To AC
High Voltage Inverter
Rectifier
Soft Start-No Inrush Current
Ferro
Simultaneous Inverter Operation No Switching
Output Battery Charger
No Risk Battery & Inverter Test
Low Voltage Boost
Low Voltage Inverter
No Cooling Fans Required
Multilink Broadband Network Powering Products For Outside Plant
MULTILINK POWER SOURCE CATALOG.iSec1:25 Sec1:25
25