Bulletin PD-20729 rev. B 01/01 MUR2020CT MURB2020CT MURB2020CT-1 Ultrafast Rectifier Features • • • • trr = 25ns IF(AV) = 20Amp VR = 200V Ultrafast Recovery Time Low Forward Voltage Drop Low Leakage Current 175°C Operating Junction Temperature Description/ Applications International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with optimized performance of forward voltage drop and ultra fast recovery time. The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as free-wheeling diode in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers. Absolute Maximum Ratings Parameters Max Units VRRM Peak Repetitive Peak Reverse Voltage 200 V IF(AV) Average Rectified Forward Current Per Leg 10 A Total Device, (Rated VR ), TC = 145°C Total Device 20 IFSM Non Repetitive Peak Surge Current Per Leg 100 IFM Peak Repetitive Forward Current Per Leg 20 (Rated VR , Square wave, 20 KHz), TC = 145°C TJ, TSTG Operating Junction and Storage Temperatures -65 to 175 °C Case Styles MUR2020CT MURB2020CT MURB2020CT-1 TO-220AB D2PAK TO-262 1 MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01 Electrical Characteristics @ TJ = 25°C (unless otherwise specified) Parameters VBR, Vr Breakdown Voltage, Blocking Voltage VF Forward Voltage IR Min Typ Max Units Test Conditions 200 - - V IR = 100µA - - 0.85 V IF = 8A, TJ = 125°C - - 1.15 V IF = 16A, TJ = 25°C - - 1.05 V IF = 16A, TJ = 125°C - - 15 µA VR = VR Rated - - 250 µA TJ = 150°C, VR = VR Rated Reverse Leakage Current CT Junction Capacitance - 55 - pF VR = 200V LS Series Inductance - 8.0 - nH . from package body Measured lead to lead 5mm Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified) Parameters trr Min Typ Max Units Test Conditions Reverse Recovery Time - - 35 - - 25 - 21 - ns IF = 0.5A, IR = 1.0A, IREC = 0.25A 35 IRRM Peak Recovery Current Qrr Reverse Recovery Charge - 1.9 - - 4.8 - - 25 - - 78 - IF = 1.0A, diF/dt = 50A/µs, VR = 30V A TJ = 25°C IF = 10A TJ = 125°C VR = 160V diF /dt = 200A/µs TJ = 25°C TJ = 125°C nC TJ = 25°C TJ = 125°C Thermal - Mechanical Characteristics Parameters Min Typ Max TJ Max. Junction Temperature Range - - - 65 to 175 TStg Max. Storage Temperature Range - - - 65 to 175 RthJC Thermal Resistance, Junction to Case Per Leg - - 2.5 RthJA ! Thermal Resistance, Junction to Ambient Per Leg - - 50 RthCS " Thermal Resistance, Case to Heatsink - 0.5 - Weight - 2.0 - Wt Mounting Torque ! Typical Socket Mount "#Mounting Surface, Flat, Smooth and Greased 2 Units °C °C/W g - 0.07 - (oz) 6.0 - 12 Kg-cm 5.0 - 10 lbf.in MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01 Reverse Current - I R (µA) 100 10 TJ = 175˚C T J = 175˚C 10 150˚C 125˚C 1 100˚C 0.1 25˚C 0.01 0.001 0 50 100 150 200 250 Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage T = 125˚C J T = 25˚C J 1000 Junction Capacitance - C T (pF) Instantaneous Forward Current - I F (A) 100 1 T = 25˚C J 100 10 0.1 0 0.4 0.8 1.2 1.6 Forward Voltage Drop - VFM (V) 1 10 100 1000 Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage 2 Fig. 1 - Typical Forward Voltage Drop Characteristics Thermal Impedance Z thJC (°C/W) 10 1 D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01 PDM t1 t2 0.1 Notes: Single Pulse (Thermal Resistance) 0.01 0.00001 0.0001 1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc 0.001 0.01 0.1 t1, Rectangular Pulse Duration (Seconds) 1 Fig. 4 - Max. Thermal Impedance Z thJC Characteristics 3 MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01 15 Average Power Loss ( Watts ) Allowable Case Temperature (°C) 180 170 DC 160 150 Square wave (D = 0.50) Rated Vr applied 140 RMS Limit 12 9 D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 DC 6 3 see note (2) 130 0 3 6 9 12 0 15 0 Average Forward Current - IF(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current 3 6 9 12 15 Average Forward Current - IF(AV) (A) Fig. 6 - Forward Power Loss Characteristics 250 50 IF = 20 A IF = 10 A IF = 5 A 40 VR = 160V TJ = 125˚C TJ = 25˚C 200 30 Qrr ( nC ) trr ( nC ) I F = 20 A I F = 10 A IF = 5 A 20 10 0 100 VR = 160V TJ = 125˚C TJ = 25˚C 100 50 di F /dt (A/µs ) 1000 Fig. 7 - Typical Reverse Recovery vs. di F /dt (3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR 4 150 0 100 1000 di F /dt (A/µs ) Fig. 8 - Typical Stored Charge vs. di F /dt MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01 Reverse Recovery Circuit VR = 200V 0.01 Ω L = 70µH D.U.T. di F /dt dif/dt ADJUST D IRFP250 G S Fig. 9- Reverse Recovery Parameter Test Circuit 3 trr IF tb ta 0 2 Q rr I RRM 4 0.5 I RRM di(rec)M/dt 5 0.75 I RRM 1 di fF/dt /dt 1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current 4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr Fig. 10 - Reverse Recovery Waveform and Definitions 5 MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01 Outline Table 10.54 (0.41) MAX. 3.78 (0.15) 3.54 (0.14) 1.32 (0.05) 2.92 (0.11) 2.54 (0.10) TERM 2 15.24 (0.60) 14.84 (0.58) BASE COMMON CATHODE 1.22 (0.05) DIA. 2 6.48 (0.25) 6.23 (0.24) 1 2 3 1 2° 2 3 ANODE COMMON ANODE CATHODE 1 2 14.09 (0.55) 3.96 (0.16) 13.47 (0.53) 3.55 (0.14) 0.10 (0.004) 2.04 (0.080) MAX. 1.40 (0.05) 2.89 (0.11) 1.15 (0.04) 0.94 (0.04) 2.64 (0.10) 0.69 (0.03) 1 2 3 0.61 (0.02) MAX. 4.57 (0.18) 4.32 (0.17) 5.08 (0.20) REF. Modified JEDEC outline TO-262 Dimensions in millimeters and (inches) 6 Conforms to JEDEC Outline TO-220AB Dimensions in millimeters and (inches) MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01 Outline Table 4.69 (0.18) 4.20 (0.16) 10.16 (0.40) REF. BASE COMMON CATHODE 1.32 (0.05) 15.49 (0.61) 6.18 (0.24) 14.73 (0.58) 5.28 (0.21) 2.61 (0.10) REF. 1.14 (0.045) 2X 1 2 3 ANODE COMMON ANODE CATHODE 1 2 0.55 (0.02) 8.89 (0.35) 1.40 (0.055) 1 4.78 (0.19) 2.32 (0.09) 3X 2 1.22 (0.05) 6.47 (0.25) 93° 0.46 (0.02) 0.93 (0.37) MINIMUM RECOMMENDED F OOTPRINT 0.69 (0.27) 11.43 (0.45) 3 4.57 (0.18) 8.89 (0.35) 4.32 (0.17) 2 17.78 (0.70) 0.61 (0.02) MAX. 5.08 (0.20) REF. 3.81 (0.15) 2.08 (0.08) 2X Conforms to JEDEC Outline D 2 PAK Dimensions in millimeters and (inches) 2.54 (0.10) 2X Ordering Information Table Device Code MUR B 20 20 CT -1 1 2 3 4 5 6 1 - Ultrafast MUR Series 2 - B 3 - Current Rating (20 = 20A) 4 - Voltage Rating (20 = 200V) 5 - CT = Center Tap (Dual) TO-220 /D2PAK/ TO-262 6 - "-1" = TO-262 Option = D2Pak / TO-262 None = TO-220AB 7 MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01 IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 01/01 8