Transcript
Bulletin PD-20729 rev. B 01/01
MUR2020CT MURB2020CT MURB2020CT-1 Ultrafast Rectifier Features • • • •
trr = 25ns IF(AV) = 20Amp VR = 200V
Ultrafast Recovery Time Low Forward Voltage Drop Low Leakage Current 175°C Operating Junction Temperature
Description/ Applications International Rectifier's MUR.. series are the state of the art Ultra fast recovery rectifiers specifically designed with optimized performance of forward voltage drop and ultra fast recovery time. The planar structure and the platinum doped life time control, guarantee the best overall performance, ruggedness and reliability characteristics. These devices are intended for use in the output rectification stage of SMPS, UPS, DC-DC converters as well as free-wheeling diode in low voltage inverters and chopper motor drives. Their extremely optimized stored charge and low recovery current minimize the switching losses and reduce over dissipation in the switching element and snubbers.
Absolute Maximum Ratings Parameters
Max
Units
VRRM
Peak Repetitive Peak Reverse Voltage
200
V
IF(AV)
Average Rectified Forward Current
Per Leg
10
A
Total Device, (Rated VR ), TC = 145°C
Total Device
20
IFSM
Non Repetitive Peak Surge Current
Per Leg
100
IFM
Peak Repetitive Forward Current
Per Leg
20
(Rated VR , Square wave, 20 KHz), TC = 145°C TJ, TSTG
Operating Junction and Storage Temperatures
-65 to 175
°C
Case Styles
MUR2020CT
MURB2020CT
MURB2020CT-1
TO-220AB
D2PAK
TO-262 1
MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01
Electrical Characteristics @ TJ = 25°C (unless otherwise specified) Parameters VBR, Vr
Breakdown Voltage, Blocking Voltage
VF
Forward Voltage
IR
Min Typ Max Units Test Conditions 200
-
-
V
IR = 100µA
-
-
0.85
V
IF = 8A, TJ = 125°C
-
-
1.15
V
IF = 16A, TJ = 25°C
-
-
1.05
V
IF = 16A, TJ = 125°C
-
-
15
µA
VR = VR Rated
-
-
250
µA
TJ = 150°C, VR = VR Rated
Reverse Leakage Current
CT
Junction Capacitance
-
55
-
pF
VR = 200V
LS
Series Inductance
-
8.0
-
nH
. from package body Measured lead to lead 5mm
Dynamic Recovery Characteristics @ TJ = 25°C (unless otherwise specified) Parameters trr
Min Typ Max Units Test Conditions
Reverse Recovery Time
-
-
35
-
-
25
-
21
-
ns
IF = 0.5A, IR = 1.0A, IREC = 0.25A
35 IRRM
Peak Recovery Current
Qrr
Reverse Recovery Charge
-
1.9
-
-
4.8
-
-
25
-
-
78
-
IF = 1.0A, diF/dt = 50A/µs, VR = 30V
A
TJ = 25°C
IF = 10A
TJ = 125°C
VR = 160V diF /dt = 200A/µs
TJ = 25°C TJ = 125°C
nC
TJ = 25°C TJ = 125°C
Thermal - Mechanical Characteristics Parameters
Min
Typ
Max
TJ
Max. Junction Temperature Range
-
-
- 65 to 175
TStg
Max. Storage Temperature Range
-
-
- 65 to 175
RthJC
Thermal Resistance, Junction to Case
Per Leg
-
-
2.5
RthJA
!
Thermal Resistance, Junction to Ambient
Per Leg
-
-
50
RthCS
"
Thermal Resistance, Case to Heatsink
-
0.5
-
Weight
-
2.0
-
Wt
Mounting Torque
! Typical Socket Mount "#Mounting Surface, Flat, Smooth and Greased
2
Units °C
°C/W
g
-
0.07
-
(oz)
6.0
-
12
Kg-cm
5.0
-
10
lbf.in
MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01
Reverse Current - I R (µA)
100
10 TJ = 175˚C
T J = 175˚C
10
150˚C 125˚C
1
100˚C
0.1 25˚C
0.01
0.001 0
50 100 150 200 250 Reverse Voltage - VR (V) Fig. 2 - Typical Values Of Reverse Current Vs. Reverse Voltage
T = 125˚C J T = 25˚C J
1000 Junction Capacitance - C T (pF)
Instantaneous Forward Current - I F (A)
100
1
T = 25˚C J
100
10
0.1 0
0.4 0.8 1.2 1.6 Forward Voltage Drop - VFM (V)
1
10 100 1000 Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance Vs. Reverse Voltage
2
Fig. 1 - Typical Forward Voltage Drop Characteristics
Thermal Impedance Z thJC (°C/W)
10
1
D = 0.50 D = 0.20 D = 0.10 D = 0.05 D = 0.02 D = 0.01
PDM
t1 t2
0.1 Notes:
Single Pulse (Thermal Resistance)
0.01 0.00001
0.0001
1. Duty factor D = t1/ t2 2. Peak Tj = Pdm x ZthJC + Tc
0.001 0.01 0.1 t1, Rectangular Pulse Duration (Seconds)
1
Fig. 4 - Max. Thermal Impedance Z thJC Characteristics
3
MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01
15 Average Power Loss ( Watts )
Allowable Case Temperature (°C)
180
170 DC
160
150 Square wave (D = 0.50) Rated Vr applied
140
RMS Limit
12
9 D = 0.01 D = 0.02 D = 0.05 D = 0.1 D = 0.2 D = 0.5 DC
6
3
see note (2)
130 0
3
6
9
12
0
15
0
Average Forward Current - IF(AV) (A) Fig. 5 - Max. Allowable Case Temperature Vs. Average Forward Current
3 6 9 12 15 Average Forward Current - IF(AV) (A)
Fig. 6 - Forward Power Loss Characteristics
250
50 IF = 20 A IF = 10 A IF = 5 A
40
VR = 160V TJ = 125˚C TJ = 25˚C
200
30
Qrr ( nC )
trr ( nC )
I F = 20 A I F = 10 A IF = 5 A
20
10
0 100
VR = 160V TJ = 125˚C TJ = 25˚C
100
50
di F /dt (A/µs )
1000
Fig. 7 - Typical Reverse Recovery vs. di F /dt
(3) Formula used: TC = TJ - (Pd + PdREV) x RthJC ; Pd = Forward Power Loss = IF(AV) x VFM @ (IF(AV) / D) (see Fig. 6); PdREV = Inverse Power Loss = VR1 x IR (1 - D); IR @ VR1 = rated VR
4
150
0 100
1000 di F /dt (A/µs )
Fig. 8 - Typical Stored Charge vs. di F /dt
MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01
Reverse Recovery Circuit
VR = 200V
0.01 Ω L = 70µH D.U.T. di F /dt dif/dt ADJUST
D IRFP250
G
S
Fig. 9- Reverse Recovery Parameter Test Circuit
3
trr
IF
tb
ta
0
2
Q rr I RRM
4
0.5 I RRM di(rec)M/dt
5
0.75 I RRM 1
di fF/dt /dt
1. diF/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current
4. Qrr - Area under curve defined by t rr and IRRM t rr x I RRM Q rr = 2 5. di (rec) M / dt - Peak rate of change of current during t b portion of t rr
Fig. 10 - Reverse Recovery Waveform and Definitions
5
MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01
Outline Table 10.54 (0.41) MAX.
3.78 (0.15) 3.54 (0.14)
1.32 (0.05)
2.92 (0.11) 2.54 (0.10) TERM 2
15.24 (0.60) 14.84 (0.58)
BASE COMMON CATHODE
1.22 (0.05)
DIA.
2
6.48 (0.25) 6.23 (0.24)
1 2 3
1
2°
2
3
ANODE COMMON ANODE CATHODE 1 2
14.09 (0.55)
3.96 (0.16)
13.47 (0.53)
3.55 (0.14)
0.10 (0.004)
2.04 (0.080) MAX. 1.40 (0.05)
2.89 (0.11)
1.15 (0.04)
0.94 (0.04)
2.64 (0.10)
0.69 (0.03)
1 2 3
0.61 (0.02) MAX.
4.57 (0.18) 4.32 (0.17)
5.08 (0.20) REF.
Modified JEDEC outline TO-262 Dimensions in millimeters and (inches)
6
Conforms to JEDEC Outline TO-220AB Dimensions in millimeters and (inches)
MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01
Outline Table 4.69 (0.18) 4.20 (0.16)
10.16 (0.40) REF.
BASE COMMON CATHODE
1.32 (0.05)
15.49 (0.61)
6.18 (0.24)
14.73 (0.58)
5.28 (0.21)
2.61 (0.10)
REF.
1.14 (0.045) 2X
1
2
3
ANODE COMMON ANODE CATHODE 1 2
0.55 (0.02)
8.89 (0.35) 1.40 (0.055)
1
4.78 (0.19)
2.32 (0.09)
3X
2
1.22 (0.05)
6.47 (0.25) 93°
0.46 (0.02)
0.93 (0.37)
MINIMUM RECOMMENDED F OOTPRINT
0.69 (0.27)
11.43 (0.45)
3 4.57 (0.18)
8.89 (0.35)
4.32 (0.17) 2
17.78 (0.70)
0.61 (0.02) MAX. 5.08 (0.20) REF.
3.81 (0.15) 2.08 (0.08) 2X
Conforms to JEDEC Outline D 2 PAK Dimensions in millimeters and (inches)
2.54 (0.10) 2X
Ordering Information Table Device Code
MUR
B
20
20
CT
-1
1
2
3
4
5
6
1
-
Ultrafast MUR Series
2
-
B
3
-
Current Rating (20 = 20A)
4
-
Voltage Rating (20 = 200V)
5
-
CT
= Center Tap (Dual) TO-220 /D2PAK/ TO-262
6
-
"-1"
= TO-262 Option
= D2Pak / TO-262
None = TO-220AB
7
MUR2020CT, MURB2020CT, MURB2020CT-1 Bulletin PD-20729 rev. B 01/01
IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 TAC Fax: (310) 252-7309 Visit us at www.irf.com for sales contact information. 01/01
8