MX1000A
Multiport V.35 Multiplexor User’s Manual
Combines up to eight async data sources BLACK BOX onto one sync WAN link or IP/Ethernet LAN connection.
®
Provides secure, reliable, and transparent multiplexing.
Customer Support Information
Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax 724-746-0746 • Mailing address: Black Box Corporation, 1000 Park Drive, Lawrence, PA 15055-1018 • Web site: www.blackbox.com • E-mail:
[email protected]
Trademarks/FCC and IC RFI Statements Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks of BB Technologies, Inc. Windows is a registered trademark of Microsoft Corporation. Any other trademarks mentioned in this manual are acknowledged to be the property of the trademark owners.
FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause interference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when the equipment is operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference, in which case the user at his own expense will be required to take whatever measures may be necessary to correct the interference. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. This digital apparatus does not exceed the Class A limits for radio noise emission from digital apparatus set out in the Radio Interference Regulation of Industry Canada. Le présent appareil numérique n’émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la classe A prescrites dans le Règlement sur le brouillage radioélectrique publié par Industrie Canada.
Page 2
724-746-5500 | blackbox.com
MX1000A
NOM Statement Normas Oficiales Mexicanas (NOM) Electrical Safety Statement INSTRUCCIONES DE SEGURIDAD
1. Todas las instrucciones de seguridad y operación deberán ser leídas antes de que el aparato eléctrico sea operado.
2. Las instrucciones de seguridad y operación deberán ser guardadas para referencia futura.
3. Todas las advertencias en el aparato eléctrico y en sus instrucciones de operación deben ser respetadas.
4. Todas las instrucciones de operación y uso deben ser seguidas.
5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante. 8. Servicio—El usuario no debe intentar dar servicio al equipo eléctrico más allá lo descrito en las instrucciones de operación. Todo otro servicio deberá ser referido a personal de servicio calificado. 9. El aparato eléctrico debe ser situado de tal manera que su posición no interfiera su uso. La colocación del aparato eléctrico sobre una cama, sofá, alfombra o superficie similar puede bloquea la ventilación, no se debe colocar en libreros o gabinetes que impidan el flujo de aire por los orificios de ventilación. 10. El equipo eléctrico deber ser situado fuera del alcance de fuentes de calor como radiadores, registros de calor, estufas u otros aparatos (incluyendo amplificadores) que producen calor. 11. El aparato eléctrico deberá ser connectado a una fuente de poder sólo del tipo descrito en el instructivo de operación, o como se indique en el aparato. 12. Precaución debe ser tomada de tal manera que la tierra fisica y la polarización del equipo no sea eliminada. MX1000A
724-746-5500 | blackbox.com
Page 3
NOM Statement/Important Warning 13. Los cables de la fuente de poder deben ser guiados de tal manera que no sean pisados ni pellizcados por objetos colocados sobre o contra ellos, poniendo particular atención a los contactos y receptáculos donde salen del aparato. 14. El equipo eléctrico debe ser limpiado únicamente de acuerdo a las recomendaciones del fabricante. 15. En caso de existir, una antena externa deberá ser localizada lejos de las lineas de energia. 16. El cable de corriente deberá ser desconectado del cuando el equipo no sea usado por un largo periodo de tiempo. 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: E l aparato parece no operar normalmente o muestra un cambio en su desempeño; o E: El aparato ha sido tirado o su cubierta ha sido dañada.
Page 4
724-746-5500 | blackbox.com
MX1000A
Warning/CE Declaration of Conformity/RoHS Compliance IMPORTANT! This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in a heavy industrial or a residential environment. WARNING: • This device contains no user-serviceable parts. The equipment should be returned to Black Box for repairs or repaired by qualified service personnel. • AC Voltage: Line voltages are present when the power cord is connected. The mains outlet shall be within 10 feet (3 m) of the device, should be easily accessible, and should be protected by a circuit breaker. • Make sure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet that has earth ground. • Hazardous network voltages are present in WAN ports, regardless of whether power to the unit is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching the cables, detach the end away from the unit first. • Do not work on the system or connect or disconnect cables during periods of lightning activity. • For units with an external power adapter, the adapter should be a listed Limited Power Source. CE Declaration of Conformity This equipment conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual recognition of their conformity. The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by CE sign on the device. RoHS Compliance In accordance with the requirements of Council Directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
MX1000A
724-746-5500 | blackbox.com
Page 5
General Observations General Observations • Clean the case with a soft, slightly moist anti-static cloth. • Place the unit on a flat surface and ensure free air circulation. • Avoid exposing the unit to direct sunlight and other heat sources. • Protect the unit from moisture, vapors, and corrosive liquids. • This device contains no user-serviceable parts. Return the equipment to Black Box for repairs. • Voltage: Line voltages are present when the power cord is connected. The AC outlet should be within 10 feet (3 m) of the device, should be easily accessible, and protected by a circuit breaker. • For AC-powered units, sure that the AC power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet that is grounded. • Hazardous network voltages are present in WAN ports, regardless of whether power to the unit is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching the cables, detach the end away from the unit first. • Do not work on the system or connect or disconnect cables during periods of lightning activity. • For units with an external power adapter, the adapter shall be a listed Limited Power Source.
Page 6
724-746-5500 | blackbox.com
MX1000A
Table of Contents Table of Contents Chapter
Page
1.
Specifications............................................................................................... 9 1.1 RS-232 Ports........................................................................................ 9 1.2 Composite Ports................................................................................... 9 1.3 Ethernet Ports...................................................................................... 9 1.4 Serial Console Port ......................................................................................... 9 1.5 Commands......................................................................................... 10 1.6 IP Services Supported......................................................................... 10 1.7 IP Connectivity Supported.................................................................. 10 1.8 Operating Environment ..................................................................... 10 1.9 System ................................................................................................11
2.
Overview .............................................................................................. 12 2.1 Introduction....................................................................................... 12 2.2 Features.............................................................................................. 12 2.3 What‘s Included................................................................................. 13 2.4 Hardware Description......................................................................... 13 2.5 Typical Application............................................................................. 15
3. Installation .............................................................................................. 16 3.1 Planning the Installation..................................................................... 16 3.1.1 Site Log.................................................................................. 16 3.1.2 Network Information ............................................................ 16 3.1.3 Network Diagram.................................................................. 16 3.1.4 IP-Related Information.............................................................17 3.1.5 Software Tools........................................................................17 3.1.6 Power Source .........................................................................17 3.1.7 Location and Mounting Requirements . .................................17 3.2 Installing the V.35 Multiplexor .......................................................... 17 3.2.1 Placing the Multiplexor ..........................................................17 3.2.2 Installing Cables..................................................................... 18 3.2.3 Connecting the Power Supply................................................ 19 4.
Initial Configuration .................................................................................. 21 4.1 Connecting the Multiplexor to Your PC............................................. 21 4.2 Configuring the Desired IP Address............. ............................................22 4.3 Connecting the Multiplexor to the Network ..................................... 24
MX1000A
724-746-5500 | blackbox.com
Page 7
Table of Contents Chapter
Page
5.
RS-232 Port Configuration......................................................................... 25 5.1 Overview............................................................................................ 25 5.2 Web Management Interface (WMI) .................................................. 26 5.3 Command Line Interface (CLI)............................................................ 27
6.
Sync Serial Configuration........................................................................... 29 6.1 Overview . ......................................................................................... 29 6.2 Web Management Interface (WMI) .................................................. 29 6.3 Command Line Interface (CLI)............................................................ 30
7. Troubleshooting ........................................................................................ 31 7.1 Contacting Black Box......................................................................... 31 7.2 Shipping and Packaging..................................................................... 31 Appendix A. Cabling ....................................................................................... 32 A.1 Introduction ...................................................................................... 32 A.2 Console.............................................................................................. 32 A.3 Ethernet............................................................................................. 32 Appendix B. Port Pinouts.................................................................................. 34 B.1 Introduction....................................................................................... 34 B.2 Console Port....................................................................................... 34 B.3 Ethernet ............................................................................................ 34 B.4 V.35 (DB25 Connector) ..................................................................... 35 B.5 RS-232 ............................................................................................... 35
Page 8
724-746-5500 | blackbox.com
MX1000A
Chapter 1: Specifications 1. Specifications 1.1 RS-232 Ports • Serial Asynchronous start-stop • Number of Ports: 8 ports • Maximum Aggregate Speed: 2 Mbps • Interface: CCITT V.24 (EIA-561) on 8-pin RJ-45 F • Data Communication Speed: Selectable 50 bps–115.2 kbps • Data Format: Selectable 5, 6, 7, or 8 bits; 1 or 2 stop bits, odd, even, or no parity • Flow Control: Software selectable (X-ON/X-OFF) or hardware (RTS/CTS) in both directions • Break Propagation: Transparent • EIA Signal Propagation: Status of local DTR signal can be propagated to the remote end • Echo: Character echo can be selectively enabled for each terminal port 1.2 Composite Ports • Autosensing 10/100BASE-TX MDI-X Ethernet/V.35 • Error Detection and Correction: 16-bit CRC-CCITT with ARQ (automatic re-transmission on error) • Speed: Selectable, serial up to 1.2 kbps–2 Mbps, Ethernet auto detect-10/100 • Interface: DB25, V.35 • Data Encoding: NRZ or NRZI • Clock: Receive clock: external; Transmit clock: selectable as internal or external 1.3 Ethernet Ports • Interface Autosensing 10/100BASE-TX MDI-X on RJ-45 1.4 Serial Console Port • Serial Communication Protocol: Asynchronous start-stop • Serial Speed: 19,200 bps • Serial Data format: 8 data bits, 1 stop bit, no parity MX1000A
724-746-5500 | blackbox.com
Page 9
Chapter 1: Specifications 1.5 Commands • Set/modify/view parameters • View status • Store parameters in non-volatile memory • Copy parameters between ports • Provide local/remote loop backs on port • Establish connection between supervisory and terminal ports • Obtain statistic reports • Unit reset; individual port reset • Remote supervisory access • Enable/Disable remote access 1.6 IP Services Supported • IPv4 • RIPv1 and v2 (RFC 1058 and 2453) • ICMP redirect (RFC 792); packet fragmentation • DiffServ/ToS set or queue per header bits • Packet policing discards excess traffic • 802.1p/Q VLAN support with 4096 IDs • Manual/IKE keying • AES/DES/3DES Encryption 1.7 IP Connectivity Supported • V.35; LMI, Q993D, ANSI 617D, Gang of Four; PPP, PAP, CHAP, LCP, IPCP • UDP • Telnet • DHCP 1.8 Operating Environment Temperature: 32–104° F (0–40° C) Humidity: 5–80% (noncondensing)
Page 10
724-746-5500 | blackbox.com
MX1000A
Chapter 1: Specifications 1.9 System • CPU Motorola MPC859 @ 50 MHz • Memory 16 MB SDRAM/4 MB Flash • Power: 100–240 VAC (50/60 Hz) • Power Dissipation: 4 W • Size: 1.6"H x 6.6"W x 7.3"D (4.1 x 16.8 x 18.5 cm) • Weight: 1.2 lb. (0.5 kg)
MX1000A
724-746-5500 | blackbox.com
Page 11
Chapter 2: Overview 2. Overview 2.1 Introduction The V.35 Multiport Asynchronous Statistical Multiplexor consolidates up to eight asynchronous data sources onto a single synchronous WAN link or IP/Ethernet LAN connection for secure, reliable, and transparent multiplexing. The multiplexor offers advanced network and transmission options. The integrated composite port provides a standard synchronous link connection to NTUs, DSUs, or traditional WAN services. By including an Ethernet port as a composite uplink, the multiplexor also “future proofs” your legacy equipment. Now multiplexed data can use existing LAN, WAN. and Internet connections—simultaneously. Data security and service quality is ensured with IPSec encryption as well as packet labeling and integrated data QoS with flow control. Reliable data is ensured via multiple CRC-16 checks, transparent data checksums and in-order data delivery. If an error occurs, the multiplexor automatically retransmits the data to ensure transparent and error-free delivery. Userconfigurable flow control, including software X-ON/X-OFF and hardware RTS/CTS, provides optimal data transfer. Integrated management offers both local and remote configuration, control, and troubleshooting. Use the supervisory port for out-of-band access or use LAN-based services such as Telnet, WEB/HTTP, and SNMP. Per-port options allow for diagnostics loops, traffic statistics, review channel status and monitor ports, and events. 2.2 Features • Eight Ports on a Single Link—Multiplex up to eight EIA-232/V.24 ports at 230.4 kbps with individually configurable speed, flow control, echo, and testing. • V.35/Ethernet Composite—Connect to any V.35 synchronous dedicated WAN or lower costs using standard PPP or Frame Relay networks. Ethernet/IP can be used over any network or Internet without the expense of dedicated lines. • Ethernet/IP Networking—User-configurable IP services ensure reliable connectivity to any LAN or WAN. • DHCP and Firewall—Permits advanced networking and flexibility. • Data Integrity and Encryption—Ensure data with CRC-16 and reliable transport. Data is secure end-to-end using IPSEC with DES/3DES or AES options and Auto MDI-X.
Page 12
724-746-5500 | blackbox.com
MX1000A
Chapter 2: Overview • Local and Remote Management—Configure and control with Web-based management, SNMP, or command line supervisory port all with password protection. 2.3 What’s Included Your package should contain the following items. If anything is missing or damaged, contact Black Box Technical Support at 724-746-5500 or
[email protected]. • Multiplexor • This printed user‘s manual • Power cable 2.4 Hardware Description Figure 2-1 shows the front panel of the multiplexor. Figure 2-2 shows the back panel of the multiplexor. Table 2-1 describes its components.
1
2
3 4 5 6
7
8
Figure 2-1. Front panel. 9
10
13
11
14
12
15
16
16
Figure 2-2. Back panel.
MX1000A
724-746-5500 | blackbox.com
Page 13
Chapter 2: Overview Table 2-1. Multiplexor front and back panel components. Number Component
Description
1
Power LED
When lit, indicates power is applied.
2
Run LED When lit, the unit is in normal operation. Flashes once per second during boot (startup).
3
Alarm LED When flashing, errors are occurring on one or more of the serial interfaces.
4
Test LED When lit, a test function, such as serial interface loopback, is in operation.
5
ETH 0 LED ON when the Ethernet connection on the corresponding port has a link indication.
6
ETH 1 LED ON when the Ethernet connection on the corresponding port has a link indication.
7
(8) LEDs
8
RJ-45 connector Used for service and maintenance, the console port, an RS-232 RJ-45 connector, connects the multiplexor to a serial terminal such as a PC or an ASCII terminal (also called a dumb terminal).
9
Power socket 100–240-VAC, 50–60 Hz, 1 A for power cable
Serial port activity
10 Serial/Link Status LED Off when no frames are detected Flashing when frames are being received or transmitted 11
DB25 F connector
Composite V.35 DTE interface
12
Activity LED
When lit, this indicates activity on the mux.
13
Reset button
Press to restart the multiplexor
14
RJ-45 connector
ETH 1 port
15
RJ-45 connector
ETH 0 port
16
(8) RJ-45 connectors Serial asynchronous RS-232 ports with an 8-pin RJ-45 F interface
NOTE: If an error occurs, all LEDs will flash once per second.
Page 14
724-746-5500 | blackbox.com
MX1000A
Chapter 2: Overview 2.5 Typical Application The multiplexor combines up to eight EIA-232/V.24 interfaces over a composite V.35 or Ethernet/IP port. Figure 2-3 shows a sample application of the multiplexor. CSU/DSU/ NTU broadband modem
MX1000A
IP, leased CSU/DSU/ line, private NTU broadline, or PSTN band modem
MX1000A
Encrypted/ QoS Tunnel Up to 8 RS-232 connections
10/100BASE-TX WAN Composite link or sync V.35 WAN Composite link Up to 8 RS-232 devices
Figure 2-3. Application example for remote office and branch office voice extension and access.
MX1000A
724-746-5500 | blackbox.com
Page 15
Chapter 3: Installation 3. Installation 3.1 Planning the Installation Before installing the multiplexor, complete the following tasks: • Create a network diagram (see Section 3.1.2, Network Information). • Gather IP-related information (see Section 3.1.4, IP Related Information for more information). • Install the hardware and software needed to configure the multiplexor. (See Section 3.1.5, Software Tools). • Verify power source reliability (see Section 3.1.6, Power Source). After you have finished preparing for installation, go to Section 3.2, Installing the V.35 Multiplexor, to install the device. 3.1.1 Site log We recommend that you maintain a site log to record all actions relevant to the system, if you do not already keep such a log. Site log entries should include information such as listed in Table 3-1. Table 3-1. Sample sIte log entries. Entry
Description
Installation Make a copy of the installation checklist and insert it into the site log. Upgrades and maintenance Use the site log to record ongoing maintenance and expansion history. Configuration changes
Record all changes and the reasons for them.
Maintenance Schedules, requirements, and procedures performed. Comments
Notes and problems.
Software
Changes and updates to software.
3.1.2 Network information Network connection considerations for planning several types of network interfaces are described in the following sections. 3.1.3 Network Diagram Draw a network overview diagram that displays all neighboring IP nodes, connected elements, and telephony components.
Page 16
724-746-5500 | blackbox.com
MX1000A
Chapter 3: Installation 3.1.4 IP-Related Information Before you can set up the basic IP connectivity for your multiplexor, you should have the following information: • IP addresses used for Ethernet LAN and WAN ports • Subnet mask used for Ethernet LAN and WAN ports • Login and password for PPPoE access • IP addresses of central TFTP server used for configuration upload and download (optional) 3.1.5 Software Tools You will need a PC (or equivalent) with Windows® Telnet or a program such as Tera Term Pro Web to configure the software on your multiplexor. You may also use a Web browser to configure the software using the built-in Web management interface. 3.1.6 Power Source If you suspect that your AC power is not reliable, for example if room lights flicker often or there is machinery with large motors nearby, have a qualified professional test the power. We recommend that you include an uninterruptible power supply (UPS) in the installation to ensure that service is not impaired if the power fails. 3.1.7 Location and Mounting Requirements The multiplexor is intended to be placed on a desktop or similar sturdy, flat surface that offers easy access to the cables. Allow sufficient space at the rear of the chassis for cable connections. Additionally, you should consider the need to access the unit for future upgrades and maintenance. 3.2 Installing the V.35 Multiplexor To install the multiplexor hardware, you will: • Place the device at the desired installation location (see Section 3.2.1, Placing the Multiplexor) • Connect the interface and power cables (see Section 3.2.2, Installing Cables) When you finish installing the multiplexor, go to Chapter 4, Initial Configuration. 3.2.1 Placing the Multiplexor Place the unit on a desktop or similar sturdy, flat surface that offers easy access to the cables. The unit should be installed in a dry environment with sufficient space to allow air circulation for cooling. MX1000A
724-746-5500 | blackbox.com
Page 17
Chapter 3: Installation NOTE: For proper ventilation, leave at least 2 inches (5 cm) to the left, right, front, and rear of the unit. 3.2.2 Installing Cables WARNING: Do not work on the system or connect or disconnect cables during periods of lightning activity. Connect the cables in the following order: CAUTION: The interconnecting cables should be acceptable for external use and should be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability. 1. Connect the twisted-pair cables to the RS-232 ports (see Connecting the RS-232 Ports, below). 2. Connect the 10/100/1000BASE-T Ethernet LAN and WAN (see Connecting the 10/100BASE-T Ethernet LAN and WAN Cables, on the next page). 3. Connect the composite port (see Connecting the V.35 Composite Port, on the next page). 4. Connect the power cable (see Section 3.2.3, Connecting the Power Supply). Connecting the RS-232 Ports The multiplexor has eight RS-232 ports. To connect the twisted-pair cable to the RS-232 port: 1. Attach the male connector of the twisted-pair cable to the female connector on the unit. 2. Attach the other end of the cable to a local RS-232 device. If the local device has a DB9 connector, use an RJ-45 to DB9 converter for the connection.
RS-232 Ports 0–7 Figure 3-1. Connecting the RS-232 ports.
Page 18
724-746-5500 | blackbox.com
MX1000A
Chapter 3: Installation Connecting the 10/100BASE-T Ethernet LAN and WAN cables The multiplexor has Automatic MDI/MDI-X (auto-crossover) detection and configuration on all Ethernet ports. Any of the ports can be connected to a host or hub/switch with a straight-through or crossover cable. 1. Connect to the subscriber port of the broadband access modem (cable, WLL) to ETH 0/0. 2. Connect port ETH 0/1 to your LAN. For details on the Ethernet port pinout and cables, refer to Appendix A, Cabling and Appendix B, Port Pinouts. Connecting the V.35 Composite port 1. Plug the V.35 WAN cable’s DB25 end into the unit’s Composite connector. 2. Plug the other end of the cable into the V.35 device. V.35 interface
Power connector
Reset Ethernet ports button
RS-232 ports
RS-232 ports
Figure 3-2. Mutliplexor with V.35 interface. 3.2.3 Connecting the Power Supply CAUTION: The interconnecting cable should be acceptable for external use and should be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability. AC Power 1. Connect the AC power cord female plug directly to the AC connector. 2. Connect the AC power cord male plug to an AC power outlet (120–240 VAC).
MX1000A
724-746-5500 | blackbox.com
Page 19
Chapter 3: Installation The Power LED blinks as the unit is powering up. When the Power LED stops blinking and remains lit, the unit is ready for user configuration. WARNING: There are no user-serviceable parts in the power supply section of the V.35 Multiplexor. For more information, contact Black Box Technical Support at 724-746-5500 or
[email protected].
Page 20
724-746-5500 | blackbox.com
MX1000A
Chapter 4: Initial Configuration 4. Initial Configuration This chapter leads you through the basic steps to set up a new multiplexor. Setting up a new multiplexor consists of the following main steps: NOTE: If you haven’t already installed the multiplexor, refer to Chapter 3, Installation. • Connecting the multiplexor to your laptop PC • Configuring the desired IP address • Connecting the multiplexor to the network 4.1 Connecting the Multiplexor to Your PC First, the multiplexor must be connected to the power supply with the power cable (see Section 3.2.3, Connecting the Power Supply). Wait until the Power LED stops blinking and stays lit constantly. Now the multiplexor is ready. CAUTION: The interconnecting cables should be acceptable for external use and should be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability. Connecting and Logging in via the Ethernet Port The multiplexor has Auto MDI/MDI-X Ethernet ports, so you can use straightthrough cables for host or hub/switch connections (see Figure 4-1). MX1000A 192.168.200.10 PC
Connect to Ethernet LAN ports, ETH0 and ETH1
Ethernet port
Figure 4-1. Connecting the multiplexor to your laptop PC via the Ethernet port. 1. To access the configuration, connect a PC’s Ethernet port to the unit’s LAN port. Use the black Ethernet cable included with your multiplexor for this purpose. MX1000A
724-746-5500 | blackbox.com
Page 21
Chapter 4: Initial Configuration 2. Configure your PC’s Ethernet port to be on the same subnet as the multiplexor. 3. Open a Telnet connection to the default LAN IP address of the multiplexor (192.168.200.10). Log into the unit using the following: login: admin password: (blank) Connecting and Logging in via the Console Port 1. To access the configuration via the console port, connect the DB9-RJ45 adapter to the DB9 serial port on the PC or dumb terminal. Use the RJ-45 straightthrough cable between the adapter and the console port on the multiplexor (see Figure 4-2). MX1000A 192.168.200.10
PC
DB9 serial port
Connect to console port
RJ-45 to DB9 adapter
Figure 4-2. Connecting the multiplexor to your laptop PC via the console port. 2. Do NOT connect the device to the Ethernet LAN now. 3. On the PC, start a HyperTerminal session at 19200 bps, 8 data bits, 1 stop bit, no flow control, and no parity. 4. Log into the unit using the following: login: admin password: (blank) 4.2 Configuring the Desired IP Address Factory-default IP settings The factory default configurations for the Ethernet interface IP addresses and network masks are listed in Table 4-1.
Page 22
724-746-5500 | blackbox.com
MX1000A
Chapter 4: Initial Configuration Both Ethernet interfaces are activated upon power-up. Table 4-1. Factory default IP address and network mask configuration.
IP Address
Network Mask
LAN interface Ethernet 0 (ETH 0)
192.168.200.10
255.255.255.0
LAN interface Ethernet 0 (ETH 0)
DHCP
DHCP
LAN interface Ethernet 1 (ETH 1)
-
-
If these addresses match those of your network, go to Section 4.3, Connecting the Multiplexor to the Network. Otherwise, refer to the following sections to change the addresses and network masks. Login To access the multiplexor, start the ssh application. Type the default IP address for the router into the address field: 192.168.200.10. Accessing your multiplexor via an ssh session displays the login screen. Type the factory default login: admin and password:
. login: admin password: Trinity# Changing the IP Address You can set your IP address and network mask for the interface ETH 0 (LAN). Within this example a network 192.168.1.1/24 address is assumed. The IP address in this example is set to 192.168.1.1 (you should set this to the IP address given to you by your network provider). Trinity# configure Trinity[config]# interface ethernet eth0 Trinity[eth-eth0]# ip address 192.168.1.1 netmask 255.255.255.0 Trinity[eth-eth0]# no ip address 192.168.200.10
MX1000A
724-746-5500 | blackbox.com
Page 23
Chapter 4: Initial Configuration NOTE: If you logged into the multiplexor with the IP address 192.168.200.10, you will need to reset your PC IP address to an address in the same network such as 192.168.1.5 and log back into the multiplexor. Connectivity via the ssh session will be lost once the 192.168.200.10 address is removed. Saving the IP Address To save the unit’s IP address, log into the unit using admin, then use the following set of commands: Trinity# [eth-eth0]# end Trinity# copy running-config startup-config Trinity# 4.3 Connecting the Multiplexor to the Network In general, the multiplexor will connect to the network via the LAN (ETH 0) port. This enables the multiplexor to offer routing services to the PC hosts on LAN (ETH 1) port. The multiplexor is equipped with Auto MDI/MDI-X Ethernet ports, so you can use straight-through or crossover cables for host or hub/switch connections. CAUTION: The interconnecting cables should be acceptable for external use and should be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability. You can check the connection with the ping command from the multiplexor to another host on the network: Trinity#ping . If the WAN address is not set to DHCP, to ping a device outside your local LAN you must first configure the default gateway.
Page 24
724-746-5500 | blackbox.com
MX1000A
Chapter 5: RS-232 Port Configuration 5. RS-232 Port Configuration 5.1 Overview This chapter describes how to configure statistical multiplexor settings. The multiplexor can act as a statistical multiplexor when configured with another multiplexor. When using two multiplexors as statistical multiplexors, one device must be configured as the master and one as the slave. Typically, the multiplexor installed at the remote site should be configured in slave mode, while the multiplexor installed at the local site should be configured in master mode. In master mode, the IP address of the remote multiplexor must be specified, and a TCP/UDP port number is optional. The port number is in the range from 0 to 40000. For example, for serial interface 1, set the serial port to 30001. In slave mode, the port number used on the slave must match the port number configured on the master. For example, for serial interface 1, set the port number to 30001. IP address: 172.16.16.3
IP address: 172.16.16.2 Master
Ethernet controller-serial-0
Slave
IP network
Serial
Ethernet controllerserial-0 Console
Figure 5-1. Multiplexor networking diagram. In the figure above, an example configuration for the master and slave units is shown here for establishing a connection between Port 0 of the master and slave units for reference:
MX1000A
724-746-5500 | blackbox.com
Page 25
Chapter 5: RS-232 Port Configuration Table 5-1. Master and Slave configuration.
Master multiplexor
Slave multiplexor
controller terminal 0
controller terminal 0
speed 9600
speed 9600
parity none
parity none
data 8
data 8
stop-bits 1
stop-bits 1
mode master 172.16.16.3 30000 mode slave 30000
no shutdown
no shutdown
exit
exit
5.2 Web Management Interface (WMI) To access the statistical multiplexor main page, click on “Interface Configuration > Terminal” from the menu on the left of the screen.
Figure 5-2. Terminal Configuration.
The Terminal Configuration main page displays the list of terminal ports and the current state of the ports. The multplexor has eight terminal ports. Port Configuration To configure a terminal port: 1. Click on the number of the port you would like to configure in the Port column on the Terminal Configuration main page. 2. The Terminal Port Status page then displays. Next, click on the “Configuration” tab at the top of the page. 3. Check the Enabled box to turn on the terminal port.
Page 26
724-746-5500 | blackbox.com
MX1000A
Chapter 5: RS-232 Port Configuration 4. Set the following fields: • Datasize: Set the data bits of the terminal port. Select an option from the range 5–8. • Flow Control: Set the flow control of the terminal port. Select None, RTS/ CTS, or X-ON/X-OFF. • Parity: Set the parity of the terminal port. Select Even, Odd, or None. • Speed: Set the baud rate for the terminal port. Select an option from the range 50–230400. • Stop Bits: Set the stop bits for the terminal port. Select 1 or 2. • Mode: Set the mode for the terminal port configuration. Select master or slave. • Remote IP Address: Set the IP address of the slave multiplexor. • Port Number: Set the Port Number to use (in the range 0–40000). 5. Click “Update” to save your settings. 5.3 Command Line Interface (CLI) The following commands are used to configure the terminal interfaces: Table 5-2. Stat Mux CLI Commands. Step
Explanation
configure controller terminal <0-7>
Enter the serial controller configuration mode.
clear
Reset the statistics shown in the show command.
data {5, 6, 7, 8}
Set the data bits of the terminal interface.
flow {none, rtscts, xonxoff}
Set the flow control of the terminal interface.
mode {none, master, slave} Set the mode of the terminal interface. An interface can only operate in one mode at a time.
MX1000A
724-746-5500 | blackbox.com
Page 27
Chapter 5: RS-232 Port Configuration Table 5-2. Stat Mux CLI Commands (continued). Step
Explanation
mode master [<0-40000>]
Enable master mode, configure remote IP address, and configure optional port number.
[allow-remote-controll
Enable remote control of the port.
mode slave [<0-40000>]
Enable slave mode and configure optional port number.
parity {even, mark, none, odd, Set the parity of the terminal interface. space} show Display the configuration and statistics for this interface. [no] shutdown
Enables or disables the terminal interface.
speed <50-230400>
Set the baud rate of the terminal interface.
stop-bits {2, 1}
Set the stop bits of the terminal interface.
show cont terminal
Show configuration of all terminal interfaces
Example—show cont terminal command: Port | Speed | Parity | Flow | Data Size | Stop Bits 0 | 9600 | none | none | cs8 | one 1 | 9600 | none | none | cs8 | one 2 |19200 | even | none | cs8 | one 3 | 9600 | none | none | cs8 | one 4 |19200 | none | none | cs8 | one 5 |19200 | none | none | cs8 | one 6 | 9600 | none | none | cs8 | one 7 | 9600 | none | none | cs8 | one
Page 28
724-746-5500 | blackbox.com
MX1000A
Chapter 6: Sync Serial Configuration 6. Sync Serial Configuration 6.1 Overview This chapter describes how to configure the sync serial interface on the V.35 multiplexor. When using two multiplexors as statistical multiplexors, the sync serial interface (labeled “Composite” on the V.35 unit) allows connectivity across a WAN link. To configure sync serial settings through the WMI, see Section 6.2, Web Management Interface (WMI). To configure sync serial settings through the CLI, see Section 6.3, Command Line Interface (CLI). 6.2 Web Management Interface (WMI) To access the statistical multiplexor main page, click on “Interface Configuration > Sync Serial” from the menu on the left of the screen.
Figure 6-1. Sync Serial Device Management page. The Sync Serial Device Management main page displays the current state of the sync serial port (V.35). You can also select to invert the clock signal and enable/ disable the port. Click “Submit” to save your settings.
MX1000A
724-746-5500 | blackbox.com
Page 29
Chapter 6: Sync Serial Configuration 6.3 Command Line Interface (CLI) Table 6-1. Stat Mux- CLI Commands. Step
Explanation
configure controller sync-serial Enter the sync-serial interface configuration mode. clock
Set the parameters.
clock invert
Invert the clock signal.
[no] shutdown
Enable or disable the sync-serial interface.
status Display the status of the sync-serial interface. show controller sync-serial Display the configuration of the sync-serial interface. Example—show controller sync-serial command:
V.35 DTE Serial Device Status
CD:
OFF
CTS:
OFF
DSR:
OFF
DTR:
ON
RTS:
OFF
Clock Invert:
False
Enabled:
False
Page 30
724-746-5500 | blackbox.com
MX1000A
Chapter 7: Troubleshooting 7. Troubleshooting 7.1 Contacting Black Box If you determine that your multiplexor is malfunctioning, do not attempt to alter or repair the unit. It contains no user-serviceable parts. Contact Black Box Technical Support at 724-746-5500 or [email protected]. Before you do, make a record of the history of the problem. We will be able to provide more efficient and accurate assistance if you have a complete description, including: • the nature and duration of the problem. • when the problem occurs. • the components involved in the problem. • any particular application that, when used, appears to create the problem or make it worse. 7.2 Shipping and Packaging If you need to transport or ship your multiplexor: • Package it carefully. We recommend that you use the original container. • If you are returning the unit, make sure you include everything you received with it. Before you ship for return or repair, contact Black Box to get a Return Authorization (RA) number.
MX1000A
724-746-5500 | blackbox.com
Page 31
Appendix A: Cabling Appendix A. Cabling A.1 Introduction This section provides information on the cables used to connect the multiplexor and the interface cards to the existing network infrastructure and to third-party products. A.2 Console The multiplexor can be connected to a serial terminal over its serial console port, as depicted in Figure A-1. CAUTION: The interconnecting cables should be acceptable for external use and should be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability. .
MX1000A 192.168.200.10
PC
DB9 serial port
Connect to console port
RJ-45 to DB9 adapter
Figure A-1. Connecting a serial terminal. NOTE: See Section B.2, Console Port, for console port pin-outs. A.3 Ethernet Ethernet devices (10BASE-T/100BASE-T/1000BASE-T) are connected to the multiplexor over a cable with RJ-45 plugs. All Ethernet ports on the multiplexor are Auto MDI/MDI-X, so you can use any straight or crossover cable to connect to hubs, switches, PCs, or other devices. CAUTION: The interconnecting cables should be acceptable for external use and should be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability.
Page 32
724-746-5500 | blackbox.com
MX1000A
Appendix A: Cabling Table A-1. Straight-through cable pinning, example 1.
RJ-45, male
RJ-45, male
1......................................................................... 1 2......................................................................... 2 3......................................................................... 3 6......................................................................... 6
NOTE: Other pins are not used.
Hub
Straight-through cable Figure A-2. Typical Ethernet straight-through cable diagram for 10/100BASE-T. Table A-2. Straight-through cable pinning, example 2.
RJ-45, male
1......................................................................... 1 2......................................................................... 2 3......................................................................... 3 6......................................................................... 6 5......................................................................... 5 7......................................................................... 7 8......................................................................... 8
MX1000A
724-746-5500 | blackbox.com
RJ-45, male
Page 33
Appendix B: Port Pinouts Appendix B. Port Pinouts B.1 Introduction This section provides pinout information for the ports of the multiplexor. B.2 Console Port Configuration settings: 19,200 bps, 8 bits, no parity, 1 stop bit, no flow control
Figure B-1. EIA-561 (RJ-45 8-pin) port.
NOTE: N/C means no internal electrical connection. B.3 Ethernet Table B-1. RJ-45 socket 10/100BASE-T.
Pin
Signal
1
TX+
2
TX-
3
RX+
6
RX-
NOTE: Pins not listed are not used.
Page 34
724-746-5500 | blackbox.com
MX1000A
Appendix B: Port Pinouts Table B-2. RJ-45 socket 1000BASE-T.
Pin
Signal
1
TRD0+
2
TRD0-
3
TRD1+
6
TRD1-
4
TRD2+
5
TRD2-
7
TRD3+
8
TRD3-
B.4 V.35 (DB25 Connector)
Figure B-2. V.35 DB25 connector pinout. B.5 RS-232
Figure B-3. EIA-561 (RJ-45 8-pin) connector pinout.
MX1000A
724-746-5500 | blackbox.com
Page 35
Black Box Tech Support: FREE! Live. 24/7.
Tech support the way it should be.
Great tech support is just 30 seconds away at 724-746-5500 or blackbox.com.
About Black Box Black Box Network Services is your source for more than 118,000 networking and infrastructure products. You’ll find everything from cabinets and racks and power and surge protection products to media converters and Ethernet switches all supported by free, live 24/7 Tech support available in 30 seconds or less. © Copyright 2011. Black Box Corporation. All rights reserved. MX1000A, rev. 2